Introduction to Signtex Lighting • A specialist in Emergency Lighting for over 30 years • All products manufactured in the USA at our facility in MD • All Signtex Lighting products comply with the buy American provision of the American Recovery & Reinvestment Act of 2009. DESIGNED & MANUFACTURED IN THE U.S.A. Signtex Lighting Specified Emergency Lighting 0 Emergency Lighting: The Conventional Approach ► Most emergency lighting fixtures were designed years ago, with little regard for ease of maintenance or cost of operation Signtex Lighting Specified Emergency Lighting 1 Most self‐contained batteries are not maintained as required: ► Too Expensive ► ► High cost of material & labor required to access batteries, remove, replace and rewire. Too Hard to Source ► Difficult to find replacement batteries. Signtex Lighting Specified Emergency Lighting 2 Conventional Emergency Lighting: Useful Life ► Batteries are subjected to: ► HIGH TEMPS IN CEILINGS ► TEMPERATURE CHANGES ► HUMIDITY ►Typical useful life: 4 Years Signtex Lighting Specified Emergency Lighting 3 Conventional Emergency Lighting: Cost ► A typical High School or larger commercial building may contain well over 1000 batteries in 1000 locations. ► The typical contractor cost to replace one single battery can be over $200 Signtex Lighting Specified Emergency Lighting 4 The Life Safety Codes ► NFPA 101: Life Safety Code ► NFPA 70: National Electrical Code ► Monthly Partial Battery Test ► Visual Inspection ► Annual Test‐ Full 90 minute discharge ► Written Test Reports Must Be AVAILABLE ON DEMAND Signtex Lighting Specified Emergency Lighting 5 The Signtex Solution: Central Battery System with •Moonlite LED ► The first UPS power system designed specifically for emergency lighting with LED fixtures. ► Radically reduces operating costs ► Ensures full compliance with the Life Safety Code Central Battery 1001000 Watts at 24 VDC Signtex Lighting Specified Emergency Lighting 6 All Fixtures Operate From One Power Source 120/ 277 VAC Central Battery System Signtex Lighting Specified Emergency Lighting 7 •Moonlite LED: Remote Fixtures Low Power & High Brightness No lamp service during a typical building lifetime. Signtex Lighting Specified Emergency Lighting 8 •Moonlite LED: Dual function includes both emergency and night or security lighting ► Fixtures operate at only 5 watts in Security Mode ► Energy Payback in under 2 Years ► No Lamp Maintenance Interior & Exterior Signtex Lighting Specified Emergency Lighting 9 Easy to Maintain ► Standard lead‐ calcium batteries are available from any commercial supply house. ► All battery maintenance can be performed by in‐ house personnel‐ No Special Training Required! Open One Door to Service 100 Fixtures in Minutes! Signtex Lighting Specified Emergency Lighting 10 Easy to install in any space. ► The cabinets are compact and can be installed in any space with a minimum one hour fire rating. WEIGHT WITH BATTS SEC EPR WATTS WATTS PANEL SIZE H" x W" x D" Lbs. 100 100 16 x 16 x 6 40 250 150 18 x 18 x 8 60 500 320 18 x 18 x 8 100 1000 600 24 x 30 x 8 180 ENC LOSURE S IZES SHOW N FO R 120 VAC INPU T. CON TACT FAC TORY FOR 277 VAC OPTIONS. EPR = POWER TO DR IVE EMERGENC Y LIGHTING FOR 90 M INUT ES SEC = POWER AVAIL ABLE FOR CONTINUO US SE CURI TY OR NIGH T LIGHTIN G Signtex Lighting Specified Emergency Lighting 11 Automatic Compliance with the Life Safety Codes ► Self‐Testing & Diagnostic Controls Standard. ► Optional Interface Control Available ► Automatic display of all diagnostic data on a building management system (BACnet). ► Remotely view all system functions from one or more locations. Signtex Lighting Specified Emergency Lighting 12 100 to 1000 watts of emergency power to any combination of Signtex products ► Minimum of 90 minutes. ► One 500 watt Panel Can Provide Emergency Lighting Over a 20,000 Square Ft. Coverage Area Signtex Lighting Specified Emergency Lighting 13 Introducing The Central Emergency & Standby System ► The first central emergency & standby lighting system N EW ! combining storage batteries & generator input. Building Utility Generator Supply Signtex Lighting Specified Emergency Lighting 14 Emergency & Standby Lighting with CES The CES panel is fed from the Standby Load Distribution Panel. No two‐ hour rated wiring or components are required, providing significant savings on any project. Class 2 wiring for emergency lighting circuits. Signtex Lighting Specified Emergency Lighting 15 Benefits No ten second time delay. Redundant Emergency Lighting System. LED emergency lighting activates immediately after power failure. Emergency lighting operates as long as the generator is running & storage batteries are maintained on full charge. If generator fails, up to 100 emergency fixtures operate for 90 minutes from each CES panel. Signtex Lighting Specified Emergency Lighting 16 Benefits No mobile or temporary emergency power required during major maintenance. Generators can be downsized by the amount of the total emergency lighting load. Exterior generator installations do not require underground feeder for emergency lighting circuits. No separate room required for emergency ATS and panel (NFPA 110 Section 7.2.2.) Signtex Lighting Specified Emergency Lighting 17 Services Offered at No Charge ► Submittal Documentation & Support ► Circuit design and full layouts on specification CAD drawings ► Load calculations and wire size selection ► Fixture Schedule ► Detailed Riser Diagram ► IES photometric Point to Point layouts Signtex Lighting Specified Emergency Lighting 18 Sample CBS Circuit Layout Signtex Lighting Specified Emergency Lighting Sample CBS Riser La Vega Intermediate School Bellmead, TX Signtex Lighting Specified Emergency Lighting 20 Cost Comparison #1 ► Armed Forces Reserve Center Middletown, CT 210,000 Square Feet 4 Stories (Excluding Exits) CBS & Moonlite LED Batteries Locations 363 8 Purchase & Install Cost $94,380 $73,865 Annual Operating Cost Maintenance & Power $16,849 $2,884 Unit Equipment Signtex Lighting Specified Emergency Lighting 21 Cost Comparison #2: Simonsdale Elementary, Virginia Beach, VA Signtex Lighting Specified Emergency Lighting 22 Cost Comparison #2: Fluorescent Unit Equipment Signtex Lighting Specified Emergency Lighting 23 Cost Comparison #2: Moonlite LED & Central Battery Signtex Lighting Specified Emergency Lighting 24 Cost Comparison #2 Unit Equipment Batteries to maintain Purchase & Install Cost Total Operating Cost Over 10 Years CBS & Moonlite LED 58 2 $15,000 $15,000 $70,000 $3,000 COST ASSUMPTIONS Battery removal/replacement: 15 mins-40 mins (varies with Fixture) Utility Power Cost: $.115/KW-Hr Mthly test per NFPA Code: Mthly test per code 1-2 mins/fixture Contractor & Installation Labor Rate: $60/hr Annual Test per NFPA Code: Annual test per code 15 mins/fixture Average Battery cost (FEB & CBS): $80 Avg battery life-all Fixtures & CBS: 4yrs: (All models) Signtex Lighting Specified Emergency Lighting 25 •Moonlite LED: Unit Equipment ► All MOONLITE LED fixtures are available with self‐ contained NICAD or NIMH batteries ► Normally On operation is available for all models Signtex Lighting Specified Emergency Lighting 26 •Moonlite LED: Optimum Efficiency ► Special optics create an elongated area of light along the path of egress. ► 1 FC along paths of egress at up to 55 ft. spacing ► Less fixtures are needed Moonlite LED General Lighting Fixtures Signtex Lighting Specified Emergency Lighting 27 Finned Aluminum Heat Transfer Bracket Test Switch (Unit Equipment) Moonlite LED LED Die Cast Heat Sink Assby Precision Optical Lens Convection Cooling Slot Acrylic Spreader Lens Signtex Lighting Specified Emergency Lighting 28 SERIES MLD: SPACING UP TO 55’ 55’ 1 Fc on 3’ path of egress 9’ Mounting Height Signtex Lighting Specified Emergency Lighting Moonlite LED 29 Moonlite LED Formed Aluminum Housing Precision Signtex Lighting Optical Lens Specified Emergency Lighting Heat Transfer Bracket LED Die Cast Heat Sink Assby 30 SERIES MLW: SPACING UP TO 45’ 45’ 3’ path of egress 8 1/2’ Mounting Height Signtex Lighting Specified Emergency Lighting 31 Moonlite LED MOONLITE Series MOE Photocell Security Lighting Control NICAD Battery Die Cast Housing LED Die Cast Heat Sink Assby Polycarbonate Lens Signtex Lighting Specified Emergency Lighting 32 Series MOE Forward Projection Signtex Lighting Specified Emergency Lighting 33 Product Comparison‐ Exterior Emergency Dual Lite Lithonia Sure Lites Phillips1 Exitronix MOE15L3 PG AFFINITY AEL DISKUSS TRITON Lamp Type (Qty) LED (3) LED (4) Standard: Xenon (2) FWD Model: LED (2) Xenon (2) LED (2) Xenon (3) Normally On2 Yes Yes (PGN only) No No Yes No Spacing3 35’ 28’ 20’ 20’ 25’ Photometric Data Not Available Photocell Control Yes No No No No No 21’ Standard Model shown. FWD Model IES data not available Signtex SCALE 12” PRODUCTS SHOWN TO SCALE 29’ Forward Projection 4’ Path4 10’ Not Available 9’ 6’ Signtex Lighting Specified Emergency Lighting 34 Ultra Thin RAPIER DIE CAST ► Rugged Ultra Thin Die Cast Aluminum LED emergency exit only 5/8" thick. ► Looks like a recessed sign when color‐ matched to mounting surface. ► Clear polycarbonate security covers are available, only 1” height above surface. ► Open face models with Custom Graphics Available. Signtex Lighting Specified Emergency Lighting 35 Crystal Edge‐Lit Exits ► Extruded Aluminum Housings and Trim. ► Only 4 Ultra‐ High Output LEDs. ► Diamond polished Acrylic lens. ► Recessed or Surface Mount. ► Custom Graphics, trim colors and finishes, letter colors and special lens sizes are all available. ► Less than 2 watts operating power. Signtex Lighting Specified Emergency Lighting 36 Crystal Edge‐Lit Exits‐ Custom 6” Disabled Graphic 10” Letters Swing Face Signtex Lighting Specified Emergency Lighting 37 Coverlite Fully Recessed High Power EBU ► Invisible in Normal Mode. If AC Power Fails, Doors Open to Expose Lamps. ► Quartz Halogen MR‐16 Lamps. ► 1 Fc emergency lighting from up to 70 ft mounting height. ► Simple mechanism: No gears or drive motor; mechanism is a magnetic solenoid and a spring ► Lamp Heads remain stationary so hot filaments cannot be damaged by sudden movement. Signtex Lighting Specified Emergency Lighting 38 New Products 2010 Over Door Mullion Mount with Moonlite LEDs NEW ! series MUE Mounts directly to extruded structural mullion beams used in typical glass‐fronted entrances and other dividing walls. N EW! series MAE A dramatic new and compact wall mounted architectural design. Signtex Lighting Specified Emergency Lighting 39 New Products 2010 High Output Surface Mount LED Down Light Designed for mounting heights up to 30 ft. or more, this LED fixture produces over 860 lumens with dual optical lenses to produce a wide, elongated beam along the path of egress. Floor Proximity Emergency Lighting NE W! Series MFP A compact, low profile and powerful LED recessed fixture for Mounting up to 4 ft from floor level. Signtex Lighting Specified Emergency Lighting 40 The most efficient means of emergency lighting for the 21st century. ► Radically Reduce Operating Costs ► Eliminate battery maintenance problems forever ► Ensure Full Compliance with the Life Safety Code Central Battery 100-1000 Watts at 24 vdc Compared with conventional fluorescent or incandescent lighting with self‐contained batteries, Signtex products can reduce operating costs by 95%. Signtex Lighting Specified Emergency Lighting MADE IN THE USA 41