G-150 June 17, 1998 Gentex SPKE Series Speakers & Speaker Strobes Section: Audio/Visual Devices GENERAL Complies with: • NFPA 72 • ADA 4.28.3 (15/75, 30/75, 110 cd) The Gentex SPKE Series of speakers and speaker strobes is designed to meet code requirements for audio, visual and voice communications. The SPKE Series devices are quality speaker products that offer dependable evacuation signaling, visual alarms, or a combination of both. The SPKE Series provides a 25 or 70.7 VRMS speaker with field-selectable power taps of 1/8 W, 1/4 W, 1/2 W, 1 W, 2 W or 4 W (70.7 V only). The Z-Series synchronized strobes require the use of the ZMS4 module. S 3722 S 5182 S 5405 California State Fire Marshal 7320-0569:116 MEA 285-91-E The SPKE devices are UL 1480 listed for use with fire protective signaling systems. STANDARD FEATURES • Strobe rating one flash per second (1 Hz), regardless of voltage. • High dB output. • Frequency range 400 – 4,000 Hz. • Screw terminals, separate in/out wiring (12 gauge). • Flush wall or ceiling mounting to a standard 4" square x 2-1/8" backbox with a 1-1/2" extension ring. • Both round (SPKE8) and square (SPKE4) speakers mount to all electrical boxes with extender ring. • Field-selectable power taps: 1/8 W, 1/4 W, 1/2 W, 1 W, 2 W, 4 W. • Speaker voltage 25 or 70.7 VRMS standard, field-selectable. • For indoor use only. • Attractive fire alarm red or off-white textured painted finish. • UL listed for fire protective services per UL 1480. Strobe is listed UL 1971 and UL 1638. • Models 15/75, 30/75 and 110 cd meet or exceed requirements of 4.28.3 of the ADA. • Synchronizable strobe on “Z”-suffix models (use with ZMS4 module). ARCHITECTS’ & ENGINEERS’ SPECIFICATIONS The fire alarm speaker shall be Gentex SPKE or equivalent. The speaker shall be capable of producing alarm tones or voice on all 25 or 70 VRMS audio systems. The speaker shall provide incremental tap settings of 1/8, 1/4, 1/2, 1, 2, or 4 watts. Minimum dB ratings at 1/4 watt shall be 81, and at 4 watts 90 dB. Tap settings shall be adjustable with field-selectable jumper pins. The speaker SPKE8-15/75CW with Strobe SPEAKER dB AT 10 FEET INPUT UL 1480 WATTS TYPICAL dB 1/8 78 1/4 81 1/2 84 SPKE4-15/75WR with Strobe 1 2 4 87 90 90 (70.7 VRMS) shall also have an optional visual signal capability. The visual signal shall have a 1 Hz flash rate regardless of input voltage. All field wiring connections shall be made via out terminal connections and the speaker strobe shall be UL, CSFM, and MEA listed with all local, state, and federal fire alarm dards. separate inor speaker and comply codes/stan- This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms, One FireLite Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 WEB: www.firelite.com DF-51799 — Page 1 of 2 MOUNTING DIAGRAMS Minimal dimension for SBB backbox approximately 3.5". A. Surface B. Flush (Wall) SPKE4 SERIES C. Flush (Ceiling) SPKE4 SERIES SPKE8 SERIES 2.75 2.75 Standard 4" square x 2-1/8" deep backbox with 1-1/2” extension ring. 2.75 Standard 4" square x 2-1/8" deep backbox with 1-1/2" extension ring. WIRING DIAGRAM SPEAKER 25 OR 70 V SOURCE TO NEXT DEVICE STROBE 24 VDC POWER SOURCE TO NEXT DEVICE EOLR NOTE: Do NOT use looped wire under terminals. Break wire run to provide supervision of connection. STROBE (optional) MAX. WIRE DISTANCE (in feet) = SPEAKER Panel Voltage — Device Minimum Voltage Total Current Draw AVAILABLE MODELS Operating Voltage SPKE4 (R or W) 25 or 70.7 VRMS SPKE8 (R or W) 25 or 70.7 VRMS STROBE RATED CURRENT Light Effective Operating Intensity Current Inrush Peak in Candela @ 24 VDC X Wire Conductivity CAUTION: Equation above applies only to regulated supplies. NOTE: Power is supplied to devices when control panel is latched. EXAMPLES: HOW TO ORDER SPKE4 = 15 = 4" square 24 VDC, baffle 15 cd strobe SPKE4-15 (WR or WW) 24 VDC 15 84 mA 114 mA 86 mA SPKE4-15/75 (WR or WW) 24 VDC 15 or 75 105 mA 220 mA 110 mA SPKE4-15/75 (CR or CW) 24 VDC 15 or 75 105 mA 245 mA 120 mA SPKE4-15/75 (WRZ or WWZ) 24 VDC 15 or 75 130 mA 490 mA 680 mA SPKE4-30/75 (WR or WW) 24 VDC 30 or 75 165 mA 120 mA 180 mA SPKE4-110 (WR or WW) 24 VDC 110 240 mA 148 mA 270 mA SPKE8-15 (WR or WW) 24 VDC 15 84 mA 114 mA 86 mA SPKE8-15/75 (WR or WW) 24 VDC 15 or 75 105 mA 220 mA 110 mA SPKE8-15/75 (CR or CW) 24 VDC 15 or 75 105 mA 245 mA 120 mA SPKE8-15/75 (WRZ or WWZ) 24 VDC 15 or 75 130 mA 490 mA 680 mA SPKE8-30/75 (WR or WW) 24 VDC 30 or 75 165 mA 120 mA 180 mA SPKE8-110 (WR or WW) 24 VDC 110 240 mA 148 mA 270 mA NOTES: 1) All 24 VDC models, strobe portion, operate from 21 to 30 VDC -20%/+10%. Operating temperatures 32 C to 120 F (0 C to 49 C). 2) Filtered DC shown; for FWR DC, see Gentex installation instructions, provided with unit. 3) For 15/75 and 30/75 models: 15 and 30 candela ratings conform to UL 1971; 75 candela ratings conform to UL 1638. Page 2 of 2 — DF-51799 FROM LAST DEVICE EOLR WIRE CONDUCTIVITY 18 AWG (0.75 mm2) — 60 16 AWG (1.30 mm2) — 95 14 AWG (2.00 mm2) — 153 12 AWG (3.25 mm2) — 244 Model Number FROM LAST DEVICE W= Wall mount R or W = Red or Off-White faceplate SPKE8 = 15/75 = C= R or W = 8" round 24 VDC, strobe Ceiling Red or baffle 15 cd (UL 1971) Off-White 75 cd (UL 1638) faceplate NEW OPTION: “Z” = synchronized strobe (15/75 wall models only)