Converting 2 prong to 3 prong grounded plug Typical Fender style WARNING! Always insure the following steps are taken BEFORE working inside any amplifier. 1. Unplug or make sure the amp is unplugged from wall AC. 2. Turn on the power and Stand-By switches. 3. Connect a jumper wire from chassis ground to pin 1 or pin 6 of any preamp tube. We recommend the first tube (12AX7 or 7025 on the far end). 4. Allow stored electricity to drain for a few minutes. 5. If in doubt, refer service to a competent technician. Follow the diagrams below and you’ll find this task to be very easy. BLACK WIRES to TRANSFORMER BEFORE FUSE HOLDER WHITE WIRE AC SW GRND Sw BLACK WIRE BLACK WIRES to TRANSFORMER AFTER FUSE HOLDER WHITE WIRE GRND Sw AC SW BLACK WIRE GREEN WIRE – MOUNT TO CHASSIS GROUND. USING AN EYELET IT IS BEST TO MOUNT TO POWER TRANSFORMER MOUNTING BOLT/NUT. TUBE AMPS 101 www.recycledsound.net