DC Inputs And Relay Outputs DC INPUT AND RELAY OUTPUT MODULES M-201 A M-209 Part Number M-201 (1 group of 8 24 Vdc inputs and 1 group of 4 NO relay) M-202 (1 group of 8 48 Vdc inputs and 1 group of 4 NO relay) M-203 (1 group of 8 60 Vdc inputs and 1 group of 4 NO relay) M-204 (1 group of 8 24 Vdc inputs and 1 group of 4 NC relay) M-205 (1 group of 8 48 Vdc inputs and 1 group of 4 NC relay) M-206 (1 group of 8 60 Vdc inputs and 1 group of 4 NC relay)) M-207 (1 group of 24 Vdc inputs and 1 group of 2 NO and 2 NC relay) M-208 (1 group of 48 Vdc inputs and 1 group of 2 NO and 2 NC relay) M-209 (1 group of 60 Vdc inputs and 1 group of 2 NO and 2 NC relay) Description This combo module with DC Inputs and relay outputs is designed to drive relays, pilot lamps, valves and other loads up to 5 A and senses the DC input Voltage and converts them to a True or False logic Signal. It has 1 group of 8 optically isolated 24/48/60 Vdc inputs (M-201, M-204, M-207/M-202, M-205, M-208/M203, M-206, M-209) and 4 relay outputs (M-201 to M-209). The relays can drive loads ranging from 24 Vdc to 110 Vdc or from 24 to 250 Vac. Two screw terminals are reserved for each relay output, though they are isolated between them. Fig. 1- DC INPUT AND RELAY OUTPUT MODULE M-201 Technical Specifications ARCHITECTURE: Umber of Groups Number of Vdc Inputs Number of Outputs 2 8 4 ISOLATION: Groups are individually isolated 8 individually isolated relay contacts. The power supply for the groups is individually isolated. The driver for each relay is 5000 Vac optically Isolated from IMB up to: 1 DC Inputs And Relay Outputs INTERNAL POWER: Provided by the IMB bus: Total Maximum Dissipation Indicator Of Source 5 Vdc, @ 60 mA typical 0.3 W None For the VDC Inputs: ARCHITECTURE: Number of Points 8 ISOLATION: Isolation up to 5000 Vac EXTERNAL POWER: Voltage Source For The Inputs: Typical Consumption Source Indicator 18-30 Vdc (M-201, M-204, M-207) 36-60 Vdc (M-202, M-205, M-208) 45-75 Vdc (M-203, M-206, M-209) 65 mA Green LED INPUTS: On State Level (True Logic) OFF State Level (False Logic) Typical Impedance Status Display Indicator Logic: Typical Input Current 15-30 Vdc (M-201, M-204, M-207) 30-60 Vdc (M-202, M-205, M-208) 38-75 Vdc (M-203, M-206, M-209) 0-5 Vdc (M-201, M-204, M-207) 0-9 Vdc (M-202, M-205, M-208) 0-12 Vdc (M-203, M-206, M-209) 3k 9 Ω (M-201, M-204, M-207) 7k5 Ω (M-202, M-205, M-208) 10 kΩ (M-203, M-206, M-209) Red LED On When Active: Transistor Conducting 7.5 mA SWITCHING INFORMATION: Minimum Voltage (0 to 1) Maximum Voltage (1 to 0) Typical Hysteresis Time From “0” To “1” Time From “1” To “0” 15 Vdc (M-201, M-204, M-207) 30 Vdc (M-202, M-205, M-208) 38 Vdc (M-203, M-206, M-209) 5 Vdc (M-201, M-204, M-207) 9 Vdc (M-202, M-205, M-208) 12 Vdc (M-203, M-206, M-209) 10 Vdc (M-201, M-204, M-207) 21 Vdc (M-202, M-205, M-208) 26 Vdc (M-203, M-206, M-209) 18 ms 40 ms For the Relay Ouputs: ARCHITECTURE Number Of Outputs 2 4 DC Inputs And Relay Outputs ISOLATION: Group is individually isolated Optical Isolation up to: Each Relay has two dedicated Terminals 5000 Vac (Before the Relay Isolation it self) Voltage Source for each Group Maximum Current Per Group Maximum Consumption Per Point Indicator Of Source Per Group 20-30 Vdc 67 mA 16,8 mA Green LED Vac Range: Vdc Range: Maximum Current For 250 Vac: Maximum Current For 30 Vdc : Status Display: Indicator Logic: Leakage: 20-250 Vac 20-110 Vdc 5A (Resistive); 2A (Inductive) 5A (Resistive); 2A (Inductive) Red LED ON if the relay coil is active 500 µA @ 100 Vac EXTERNAL SOURCE: OUTPUTS: SWITCHING INFORMATION: RC Protection Circuit Time To activate Time to deactivate 62 Ω in series with 0.0 uF 10 ms 10 ms Mechanic Switching Cycles: 100.000 operations minimum @ 5 A 250 Vac ELECTRICAL SERVICE LIFE: DIMENSIONS AND WEIGHT: Weight 39,9 x 137,0 x 141,5 mm (1,57 x 5,39 x 5,57 in) 0.298 Kg One Cable Two Cables 14 AWG (2 mm2) 20 AWG (0.5 mm2) Dimensions (W x H x D) CABLE: Note: To increase the service of life of the contacts and to protect the module from potential reverse voltage damage, externally connect a clamping diode in parallel with each inductive DC Load or connect and RC snubber circuit with each inductive AC Load. 3