A WORLD POWER IN CABLE SUPPLY www.clevelandcable.com Distribution Centres CLEvELAND CABLE LOCATIONS 2 As is illustrated within our catalogue, we stock a comprehensive range of cables for every conceivable application. All types shown are considered as standard items to our range and are always available for immediate delivery. Our stocks are extremely large and unrivalled in the industry. We are fortunate to have a very experienced and dedicated team of people who are able to assist and advise. Additionally our policy of continuing investment in the best available technology, warehousing, handling and measuring equipment and delivery vehicles enables us to guarantee all our customers an extremely high quality service. Enquiries are welcome from customers worldwide. Our export service is efficient and reliable with the ability to ship by air or sea freight to any destination. Please feel free to contact the distribution centre of your choice for an immediate, professional and trouble free service. Middlesbrough Bristol Glasgow Milton Keynes 01642 241133 01179 382222 0141 646 5000 01908 221414 London Newcastle Warrington Aberdeen 0208 311 4141 0191 263 3363 01925 655383 01224 330565 3 Cleveland Cable Company, established in 1978, is undoubtedly the foremost distributor of electrical cables in Great Britain and possibly Europe. The Head Office and principal stocking location is located at Middlesbrough in the North East of England. This site covers an area of twelve acres and includes over 160,000 square feet of warehousing. Additionally there are regional depots at Bristol, Glasgow, London, Milton Keynes, Newcastle and Warrington. Each location holds comprehensive stocks and is equipped with the most modern handling and measuring equipment. Deliveries are made by our own fleet of purpose-designed vehicles, all of which are fitted with hydraulic lifting equipment for safe offloading onsite and also efficient collection of empty drums. 4 Middlesbrough Head Office Warehouses and Stockyard 5 Gland Selection Guidelines Gland selection Guidelines There are many factors to be considered when selecting cable glands for industrial installations. Neglecting to give due attention to these factors could cause unnecessary difficulties at a crucial point in time where most inconvenience and expense can result. It is most desirable to avoid discovering that, once all other equipment is on site or installed, the glands have not been ordered or are the wrong size or type. Good practice would be to allocate some planning and preparation time to cable gland selection. This will help avoid the possible disruption which could result at a critical point of the installation process. In the event of a project schedule of cables being available Cleveland Cable Company are happy to offer a gland selection and sizing service. Please contact any of our depots for further information or assistance. Here is a summary of some aspects to carefully consider when selecting cable glands. • Identify the type of cable to be used. • Check the construction, size and material properties of the cable. • Check the type and material of the cable armour (*) • Check the short circuit fault current rating of the cable armour (**) • Check the actual diameter of the inner bedding (where present) against this catalogue. • Check the actual diameter of the lead covering (where present) against this catalogue. • Check the actual size of the overall cable diameter against this catalogue. • Check the size and type or armour or braid (where present) against this catalogue. • Check any special environmental requirements in relation to corrosion protection. • Check the material of the mating electrical enclosures to eliminate dis-similar metals. • Consider whether any protective plating is required to be applied to the cable gland. 6 • Check the type and size of the cable entry hole in the mating electrical equipment. • Check the ingress protection rating of the electrical equipment or site standard. • Check whether a single or double seal cable gland is required. • Check whether an entry thread seal is required for IP66 (or IP67/IP68) conditions. • Check whether fixing accessories such as locknuts and serrated washers are required. • Check whether earth tags are required. (**) • Check whether shrouds are required. • Select a corresponding cable gland type from this catalogue. • For installations in Hazardous Areas, special considerations should be taken into account to ensure compliance with national or international codes of practice. • Check whether a thread conversion adaptor or reducer is required to make the installation. • Select corresponding adaptors or reducers from this catalogue. • Check whether any stopper plugs are required to close unused cable entries. • Select corresponding stopper plugs from this catalogue. Note (*): If the cable armour is of a non standard material, i.e. Aluminium Wire Armour, it may be necessary to consider an alternative cable gland material, e.g. Aluminium. Note (**): For certain medium voltage and high voltage cables where the fault current carrying capacity of the cable armour is greater than that of the standard earth tag it may be necessary to consider a cable gland utilising the a heavy Cast Integral Earth Lug (CIEL) option which can be identified in the body of this catalogue. Cable Sections SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables 6491X (HO7v-R) PvC insulated wiring, 1.5mm2 – 630mm2 ............................................................................................................................12 Bare copper strand, soft drawn to BS6360/81, 6mm2 – 400mm2 ............................................................................................................12 6181Y PvC insulated, PvC sheathed surface wiring, 1.0mm2 – 120mm2 ..................................................................................................13 624*Y PvC insulated, PvC sheathed surface wiring, 1mm2 – 16mm2........................................................................................................13 BS5467 Mains & control, XLPE, PvC SWA, PvC, 1.5mm2 – 16mm2 including multicores............................................................14 BS5467 Mains, XLPE, PvC, SWA, PvC, copper conductors, 25mm2 – 400mm2 ............................................................................15 BS5467 Mains, XLPE, PvC, SWA, MDPE, copper conductors 4mm2 – 16mm2 ..................................................................................16 BS5467 Mains, XLPE, PvC, SWA, MDPE, copper conductors 25mm2 – 400mm2 ..........................................................................17 BS5467 Mains, XLPE, PvC, SWA, PvC, aluminium conductors, 25mm2 – 300mm2 ......................................................................18 BS7889 Mains, single core, XLPE, PvC, non-armoured, 50mm2 –1000mm2 ......................................................................................18 BS5467 Mains, single core, XLPE, PvC, aluminium wire armoured, PvC, 50mm2 – 1000mm2 ..............................................19 Mines & Quarries Mains, XLPE, PvC, SWA, PvC, with 60% Conductivity in armour, 10mm2 – 300mm2 ........................20 EEMUA 133 Multicore, XLPE, lead sheathed, PvC, SWA, PvC, Control cable for petro-chemical industries, 1.5mm2 – 4mm2....................................................................................................................................................................................................21 EEMUA 133 Mains, XLPE, lead sheathed, PvC,SWA, PvC, for petro-chemical industries, 1.5mm2 – 16mm2..................22 EEMUA 133 Mains, XLPE, lead sheathed, PvC, SWA, PvC, for petro-chemical industries, 25mm2 – 300mm2 ..........23 NYY non-armoured Mains Cable 1.5mm2 - 16mm2 ..............................................................................................................................................24 Cathodic Protection Cables. XLPE, PvC, and XLPE, PvC, SWA, PvC, 6mm2 – 185mm2............................................................25 Concentric, split & straight, single phase service cable, 4mm2 – 35mm2..............................................................................................26 SECTION 2 3300V Mains Cables BS5467 Mains, single core XLPE, PvC, aluminium wire armoured, PvC, 3300v, 120mm2 – 630mm2 ..............................28 BS6724 Mains, single core XLPE, LSZH, aluminium wire armoured, LSZH, 3300v, 120mm2 – 630mm2 ........................28 BS5467 Mains three core, XLPE, PvC, SWA, PvC, 3300v, 16mm2 – 400mm2 ................................................................................29 BS6724 Mains three core, XLPE, LSZH, SWA, LSZH, 3300v, 16mm2 - 300mm2 ............................................................................29 Mines & Quarries Mains, XLPE, PvC, SWA, PvC, with 60% conductivity in armour, 3300v, 16mm2 – 300mm2........30 EEMUA 133 Mains, XLPE, Lead sheathed, PvC, SWA, PvC, for petro-chemical industries, 3300v, 25mm2 – 300mm2 ................................................................................................................................................................................................30 SECTION 3 LSZH Fixed Wiring & Mains 6491B (H07Z-R) LSZH insulated wiring, 1.5mm2 – 630mm2 ........................................................................................................................32 6181B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm2 – 35mm2 ............................................................................................33 624*B XLPE insulated, LSZH sheathed surface wiring 1.5mm2 – 16mm2 ..............................................................................................33 BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm2 – 16mm2 including multicores ...................................................34 BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm2 – 400mm2 ....................................................................................................................35 BS6724 Mains, single core, XLPE, LSZH, 50mm2 – 1000mm2 ....................................................................................................................36 BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm2 – 1000mm2 ........................................37 BS8436 Protected fixed wiring cable, 1mm2 – 10mm2 ......................................................................................................................................38 7 Cable Sections SECTION 4 Medium Voltage 11000V & Above BS6622 Mains, single core, XLPE, CTS, PvC, aluminium wire armoured, PvC, 11000v, 50mm2 – 630mm .................40 BS6622 Mains, three core, XLPE, CTS, PvC, SWA, PvC, 11000v, 25mm2 – 400mm2 ................................................................40 BS6622 Mains, three core, aluminium conductor XLPE, CTS, PvC, SWA, PvC, 11000v, 95mm2 – 300mm2 ................41 Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000v, utility cable, 70mm2 – 300mm2..................................41 Paper insulated, BS6480 Mains, three core, SWA, PvC, 11000v, 25mm2 – 400mm2 ..................................................................42 BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000v, 50mm2 – 630mm2 ..........43 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000v, 35mm2 – 400mm2 ............................................................43 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000v and 33000v, 95mm2 – 185mm2 ............................44 SECTION 5 High voltage 33000v Service And Windfarm Cables BS7870 Mains, single core, aluminium conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2............................46 BS7870 Mains, single core, copper conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2 ..................................46 SECTION 6 Fire Protection, Alarm & Security Cables Mineral Insulated........................................................................................................................................................................................................................48 BS5839/BS7629 Fire performance alarm and security cable, 1mm2 – 4mm2 ..................................................................................49 BS5839/BS7629 Enhanced fire performance alarm and security cable 1.5mm2 – 4mm2 ........................................................50 BS6387 Fire performance single core cable, 1.5mm2 – 16mm2 ..................................................................................................................50 BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,1.5mm2 – 16mm2, including multicores ............................................................................................................................................51 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm2 – 400mm2 ........................................52 BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant, enhanced, 1.5mm2 – 16mm2, including multicores. ..............................................................................................................................................53 BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced, 25mm2 – 400mm2 ...............54 SECTION 7 Flexible Cables, PVC and Rubber PVC and LSZH flexible cables PvC flexible cables 218*Y (H03vv-F) PvC, PvC, 0.5mm2 – 0.75mm2 ..................................................................................................56 318*Y (H05vv-F) PvC, PvC, 0.5mm2 – 2.5mm2 ....................................................................................................................................................56 309*Y Heat resisting PvC, PvC, 0.5mm2 – 2.5mm2 ............................................................................................................................................57 Arctic grade low temperature flex, 1.5mm2 – 6mm2 ..........................................................................................................................................57 318*B (H05ZIZI-F) LSZH, LSZH, 0.75mm2 – 2.5mm2 ........................................................................................................................................58 8 Cable Sections YY Control cable, 0.75mm2 – 1.5mm2 ..........................................................................................................................................................................59 YY Control cable, 2.5mm2 – 50mm2 ............................................................................................................................................................................60 SY Control cable, 0.75mm2 – 2.5mm2 ..........................................................................................................................................................................61 SY Control cable, 4.0mm2 – 95mm2 ............................................................................................................................................................................62 CY Control cable, 0.5mm2 – 16mm2 ..............................................................................................................................................................................63 YY Control cable, LSZH, 0.75mm2 – 25mm2 ..........................................................................................................................................................64 CY Control cable, LSZH, 0.75mm2 – 1.5mm2 ..........................................................................................................................................................64 SY Control Cable, LSZH, 1.5mm - 6mm2 ....................................................................................................................................................................65 Tri-rated and Bi-rated BS6231, switchgear and control panel wire, 0.5mm2 – 400mm2 ..........................................................66 2491B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring, 1.5mm2 – 240mm2 ............................................................66 6381Y PvC, PvC, 6mm2 – 400mm2 ..............................................................................................................................................................................67 Solar Energy Cables 1.5mm2 – 35mm2 ........................................................................................................................................................................67 Rubber flexible cables BS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 – 2.5mm2 ..........................................................................68 BS7919 EPR insulated, CSP sheathed, flexible mains 4mm2 – 16mm2 ....................................................................................................69 BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm2 – 630mm2 ..........................................................................................70 HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm2 – 50mm2 ........................................................................................71 HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm2 – 630mm2 ....................................................................................72 380*P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm2 – 16mm2 ................................................73 BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm2 – 2.5mm2 ....................................................................73 Coil lead BS6195 EPR, CSP, 0.5mm2 – 400mm2 ...................................................................................................................................................74 Welding cable, O361TQ EPR, CSP, 16mm2 – 185mm2 ........................................................................................................................................75 Flatform and silicon cables Flatform cable, EPR, PCP, 1.5mm2 – 70mm2 ............................................................................................................................................................75 Flatform cable, PvC, PvC, 1.5mm2 – 95mm2............................................................................................................................................................76 Silicon insulated, silicon sheathed, flexible cable, 0.75mm2 – 2.5mm2 ....................................................................................................76 SECTION 8 Instrumentation, Control & Communication Cables BS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2. ............................................................................................................................................................78 BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2............................................................................................................................79 BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm2 – 2.5mm2, part 1 and part 2 ..80 BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2 ............................................................................................................................81 BS5308 Control and instrumentation non armoured with collective screen LSZH, 0.75mm to 1.5mm part 1 ............82 BS5308 Control and instrumentation non armoured with individual and collective screen LSZH, 0.5mm to 0.75mm part 1 ....................................................................................................................................82 BS5308 Control and instrumentation armoured with collective screen LSZH, 0.5mm to 2.5mm part 1........................83 BS5308 Control and instrumentation armoured with individual and collective screen LSZH, 0.5mm to 1.5mm part 1........83 BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2 ..................................................................................................................................84 BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2..................................................................................................85 BS5308 part 1 core identification ..................................................................................................................................................................................86 BS5308 part 2 core identification ..................................................................................................................................................................................87 British Steel specification CES20 type 134, 0.75mm2........................................................................................................................................88 British Steel specification CES20 type 143, 0.75mm2........................................................................................................................................89 CW1308 telephone cable....................................................................................................................................................................................................90 Telephone cable to ENATS 09-6 standard................................................................................................................................................91/92/93 Utility Industry PvC Control Cables, ENATS 09-6 2.5mm2 ............................................................................................................................93 ENATS 09-6 section 3.6 core identification............................................................................................................................................................94 9 Cable Sections ENATS 09-6 section 4.5 core identification............................................................................................................................................................94 Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573 ..................................................................................95 Defence standard screened cable type 61-12 PvC and LSZH ....................................................................................................................96 Defence standard 61-12 parts 4 & 5 core identification ...................................................................................................................................97 Thermocouple extension and compensating cable, 0.75mm2 ....................................................................................................................98 Thermocouple core identification..................................................................................................................................................................................99 Traffic signal cable, loop feeder cable and loop detector cable ........................................................................................100/101/102 SECTION 9 Data Cables Belden equivalents ................................................................................................................................................................................................................104 Coaxial cables............................................................................................................................................................................................................................104 Cat 5 data cables....................................................................................................................................................................................................................104 Cat 6 data cables....................................................................................................................................................................................................................104 SECTION 10 Railway Cables Signalling cable types A1, A2, A3, B1 and B2, 0.75mm2 – 95mm2 ..........................................................................................................106 Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm2 – 35mm2 ............................................................................107 Train protection warning system cable ....................................................................................................................................................................108 Point heater cable ..................................................................................................................................................................................................................108 Axle counting cable ..............................................................................................................................................................................................................109 Datalink cable ............................................................................................................................................................................................................................110 Fixed Telephone Network (FTN) copper trackside cable ............................................................................................................................1 1 1 Power cables, 16mm2 – 95mm2 ......................................................................................................................................................................................112 Trackfeeder cables, 150mm2 – 1000mm2 ................................................................................................................................................................112 SECTION 11 Marine And Offshore Cables UKOOA Cable Identifier ......................................................................................................................................................................................................114 EPR insulated, non-armoured shipwiring cable, 1.5mm2 –6mm2 ..............................................................................................................115 EPR insulated, non-armoured shipwiring cable, 10mm2 – 630mm2 ......................................................................................................116 EPR insulated, braided armoured shipwiring cable, 1.5mm2 – 4mm2 ....................................................................................................117 EPR insulated, braided armoured shipwiring cable, 6mm2 – 300mm2 ................................................................................................118 EPR insulated, single core braided shipwiring cable, 6mm2 – 630mm2 ..............................................................................................119 MICA, EPR insulated, braided armoured shipwiring cable 1.5mm to 10mm ....................................................................................119 EPR insulated instrumentation cable, braided armoured with collective screen 0.75mm to 1.5mm ..............................120 EPR insulated instrumentation cable, braided armoured with individual screen 0.75mm to 2.5mm ....................................121 MICA, EPR insulated instrumentation cable, braided armoured with collective screen 0.75mm to 1.5mm................122 MICA, EPR insulated instrumentation cable, braided armoured with individual screen 0.75mm to 2.5mm......123/124 SECTION 12 Installation Accessories ..............................................................................................125 10 Low voltage PvC Fixed Wiring & Mains Cables SECTION 1 Low voltage PvC Fixed Wiring & Mains Cables Low voltage PvC Fixed Wiring & Mains Cables 6491X (Ho7V-R) PVc Stranded plain annealed compacted circular copper conductor, PvC outer sheath. Ref 6491X. Harmonised code HO7v-R. 450/750 volts grade to BS6004. Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Brass A2 Nylon A2 6491X1/5 6491X2/5 6491X4 6491X6 6491X10 6491X16 6491X25 6491X35 6491X50 6491X70 6491X95 6491X120 6491X150 6491X185 6491X240 6491X300 6491X400 6491X500 6491X630 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.50 21 35 50 71 120 180 280 380 510 720 990 1200 1500 1900 2500 3000 3950 4950 6250 3.00 3.65 4.20 4.75 6.15 7.10 8.90 9.95 11.70 13.35 15.60 17.20 19.10 21.30 24.30 27.05 30.35 32.80 36.50 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 20 25 25 25 32 32 40 40 50S 50S 16 16 16 16 16 16 20 20 20 25 25 25 32 32 32 40 40 50 50 Temperature limits: -15 to +70°C. *Bending radius: up to 10mm2 - 3 x overall diameter. above 25mm2 - 6 x overall diameter. Standard colours available: 1.5mm2 & 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, violet, Pink 4mm2-630mm2 - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +60°C. BaRe coPPeR stRand Stranded plain annealed compacted circular copper conductor, non insulated and non sheathed. 450 volts grade, soft drawn to BS6360/81. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) CB006 CB010 CB016 CB025 CB035 CB050 CB070 CB095 CB120 CB150 CB185 CB240 CB300 CB400 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 58 96 154 240 336 480 672 912 1152 1440 1776 2304 2800 3750 3.0 4.2 5.1 5.9 7.8 8.8 9.8 12.5 12.8 14.4 16.1 19.8 20.6 26.4 Temperature limits: - 15 to + 70°C. *Bending radius: Up to 10mm - 3 x overall diameter. Above 25mm - 6 x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 12 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables suRFace WiRinG caBles PVc 6181Y Plain annealed stranded circular copper conductor, single core, PvC insulated, PvC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004 120mm rated at 600/1000 v. Brown/Grey or Blue/Grey. Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6181Y1 6181Y1/5 6181Y2/5 6181Y4 6181Y6 6181Y10 6181Y16 6181Y25 6181Y35 6181Y50 6181Y70 6181Y95 6181Y120 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19.2.52 37/2.03 1 1 1 1 1 1 1 1 1 1 1 1 1 Weight Overall (Kg/Km) Diameter (mm) 28 36 51 75 98 150 220 340 440 540 750 1010 1250 4.5 5.1 6.0 6.8 7.4 8.8 10.5 12.5 13.5 14.38 15.3 17.7 19.3 Gland Size (mm) Nylon Cleat Size 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 25 32 0.5 0.5 0.6 0.6 0.7 0.7 0.8 Temperature limits: -15 to +70°C. •Bending radius: up to 10mm2 - 3 x overall diameter. over 10mm2 - 4 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. suRFace WiRinG caBles PVc 624*Y Plain annealed copper conductor, PvC insulated one, two or three cores laid flat with an uninsulated circuit protective conductor and PvC sheathed. Grey. Ref 6241/2/3Y 300/500 v to BS6004. Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) 6241Y1BR 1.0 6241Y1/5BR 1.5 6242Y1 1.0 6242Y1/5 1.5 6242Y1/5BRBR 1.5 6242Y2/5 2.5 6242Y4 4.0 6242Y6 6.0 6242Y10 10.0 6242Y16 16.0 6243Y1 1.0 6243Y1/5 1.5 6243Y2/5 2.5 Stranding (mm) No. Of Cores CPC Size (mm2) Weight (Kg/Km) Overall Diameter (mm) 1/1.13 1/1.37 1/1.13 1/1.38 1/1.38 1/1.77 7/0.85 7/1.04 7/1.35 7.1.70 1/1.13 1/1.37 1/1.77 1 1 2 2 2 2 2 2 2 2 3 3 3 1.0 1.0 1.0 1.0 1.0 1.5 1.5 2.5 4.0 6.0 1.0 1.0 1.5 49 51 69 85 85 120 175 240 390 560 92 115 170 4.15 X 5.40 4.65 X 5.80 4.10 X 8.65 4.55 X 8.80 4.55 X 8.80 5.40 X 10.50 6.10 X 12.00 6.90 X 13.80 8.40 X 18.50 9.70 X 20.60 4.60 X 10.20 4.75 X 11.45 5.45 X 13.40 Temperature limits: - 15 to + 70°C. *Bending radius: Up to 10mm - 3 x overall diameter. Above 10mm - 6 x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 13 Low voltage PvC Fixed Wiring & Mains Cables Mains and contRol caBles PVc Stranded plain annealed copper conductors, XLPE insulated, PvC bedding, galvanised steel wire armour, PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores XLPE2X1/5 XLPE3X1/5 XLPE4X1/5 XLPE5X1/5 XLPE7X1/5 XLPE8X1/5 XLPE10X1/5 XLPE12X1/5 XLPE19X1/5 XLPE27X1/5 XLPE37X1/5 XLPE48X1/5 XLPE2X2/5 XLPE3X2/5* XLPE4X2/5 XLPE5X2/5 XLPE7X2/5 XLPE10X2/5 XLPE12X2/5 XLPE19X2/5 XLPE27X2/5 XLPE37X2/5 XLPE48X2/5 XLPE2X4 XLPE3X4* XLPE4X4 XLPE5X4 XLPE7X4 XLPE12X4 XLPE19X4 XLPE27X4 XLPE2X6 XLPE3X6* XLPE4X6 XLPE5X6 XLPE7X6 XLPE2X10 XLPE3X10* XLPE4X10 XLPE5X10 XLPE7X10 XLPE2X16 XLPE3X16* XLPE4X16 XLPE5X16 XLPE7X16 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 10.0 10.0 16.0 16.0 16.0 16.0 16.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 7/1.70 2 3 4 5 7 8 10 12 19 27 37 48 2 3 4 5 7 10 12 19 27 37 48 2 3 4 5 7 12 19 27 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 Weight Overall (Kg/Km) Diameter (mm) 234 271 306 356 391 501 650 657 863 1310 1590 1900 312 343 392 463 509 850 861 1324 1760 2185 2800 373 421 496 573 741 1255 1690 2250 450 515 696 808 1100 590 781 927 1095 1500 893 1059 1269 1679 2150 11.06 11.54 12.26 13.23 14.1 16.7 18 18.3 20.78 25.1 27.5 30 12.4 12.99 13.86 14.92 15.96 20 21.11 25.16 30 33 36 13.38 14.05 15.04 16.35 18.21 24.24 27.61 32 14.38 15.14 17.03 18.39 21.9 16.18 17.76 19.09 20.91 25 19.06 20.35 21.95 25.19 28.1 Gland Size (mm) Nylon Cleat Size 20/16 20/16 20/16 20S 20S 20 20 20 25 25 32 32 20S 20S 20S 20S 20 25 25 25 32 40 40 20S 20S 20 20 20 25 32 32 20S 20 20 20 25 20 20 25 25 25 25 25 25 25 32 0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.8 0.9 1.0 1.1 1.2 0.5 0.6 0.6 0.6 0.8 0.8 0.9 1.0 1.2 1.4 1.6 0.6 0.6 0.6 0.7 0.8 1.0 1.1 1.4 0.6 0.7 0.7 0.8 0.9 0.7 0.8 0.8 0.9 1.0 0.8 0.9 0.9 1.1 1.2 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - up to 6mm2 - White with Black numbers. 5 core - 10mm2 and 16mm2 - Brown, Black, Grey, Blue, Green/Yellow 1.5 & 2.5 - 2,3,4 core also available in white numbered cores to ESI 09-6. Should not be installed at temperatures below 0°C or above +60°C. * Additionally these cables are stocked with Brown, Blue and Green/Yellow core identification. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 14 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables Mains caBles PVc Stranded plain annealed copper conductors, XLPE insulated, PvC bedding, galvanised steel wire armour, PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6942X25 6943X25 6944X25 6945X25 6942X35 6943X35 6944X35 6945X35 6942X50 6943X50 6944X50 6945X50 6942X70 6943X70 6944X70 6945X70 6942X95 6943X95 6944X95 6945X95 6942X120 6943X120 6944X120 6942X150 6943X150 6944X150 6942X185 6943X185 6944X185 6942X240 6943X240 6944X240 6942X300 6943X300 6944X300 6942X400 6943X400 6944X400 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 400 400 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 61/2.85 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 Weight Overall (Kg/Km) Diameter (mm) 1050 1500 1800 2200 1400 1800 2200 2800 1750 2250 2850 3850 2200 3000 4100 5100 3000 4150 5200 7700 3600 4950 6700 4250 6300 7900 5500 7650 9650 6900 9650 12400 8200 11550 14800 10100 14350 19300 20 23 25 29 22 26 28 33 25 28 31 38 28 32 37 43 32 37 40 52 35 40 46 37 45 49 43 49 55 48 56 62 50 59 66 56 65 75 Gland Size (mm) Nylon Cleat Size 25 25 32 32 25 32 32 40 32 32 32 40 32 32 40 50S 40 40 50S 50 40 50S 50 40 50 50 50 50 63S 50 63S 63 50 63 75S 63S 75S 75 0.8 1.0 1.0 1.2 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.8 TC9 1.4 1.8 2.0 1.6 1.8 2.0 1.8 2.0 TC9 2.0 TC9 TC10 2.0 TC10 TC11 TC9 TC11 TC12 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue,Green/Yellow. Should not be installed at temperatures below 0°C or above +60°C. nB 5 coRe 95MM and aBoVe aRe ManuFactuRed to iec60502-1 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 15 Low voltage PvC Fixed Wiring & Mains Cables FiXed WiRinG and Mains caBles MdPe sHeatHed Stranded plain annealed copper conductor, XLPE insulated, PvC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v grade generally to BS5467. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6942PE4 6943PE4 6944PE4 6942PE6 6943PE6 6944PE6 6942PE10 6943PE10 6944PE10 6942PE16 6943PE16 6944PE16 6945PE16 4.0 4.0 4.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 16.0 7/0.86 7/0.86 7/0.86 7/1.06 7/1.06 7/1.06 7/1.36 7/1.36 7/1.36 7/1.74 7/1.74 7/1.74 7/1.74 2 3 4 2 3 4 2 3 4 2 3 4 5 Weight Overall (Kg/Km) Diameter (mm) 344 389 462 418 480 655 552 739 881 847 1006 1211 1606 13.4 14.1 15.0 14.4 15.1 17.0 16.2 17.8 19.1 19.1 20.4 22.0 25.2 Gland Size (mm) Nylon Cleat Size 20S 20S 20S 20S 20S 20 20 20 25 20 25 25 25 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.9 0.9 1.0 Temperature limits: - 15 to + 90°C. Bending radius: 8 x Overall Diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 16 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables FiXed WiRinG and Mains caBles MdPe sHeatHed Stranded plain annealed copper conductor, XLPE insulated, PvC bedding, galvanised steel wire armour, MDPE outer sheath. Black. 600/1000v grade generally to BS5467. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6942PE25 6943PE25 6944PE25 6945PE25 6942PE35 6943PE35 6944PE35 6945PE35 6942PE50 6943PE50 6944PE50 6945PE50 6942PE70 6943PE70 6944PE70 6945PE70 6942PE95 6943PE95 6944PE95 6945PE95 6942PE120 6943PE120 6944PE120 6942PE150 6943PE150 6944PE150 6942PE185 6943PE185 6944PE185 6942PE240 6943PE240 6944PE240 6942PE300 6943PE300 6944PE300 6943PE400 6944PE400 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 400 7/2.21 7/2.21 7/2.21 7/2.21 7/2.66 7/2.66 7/2.66 7/2.66 19/1.88 19/1.88 19/1.88 19/1.88 19/2.21 19/2.21 19/2.21 19/2.21 37/1.88 37/1.88 37/1.88 37/1.88 30/2.32 30/2.32 30/2.32 37/2.32 37/2.32 37/2.32 37/2.55 37/2.55 37/2.55 60/2.32 60/2.32 60/2.32 61/2.66 61/2.66 61/2.66 60/2.96 60/2.96 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 Weight Overall (Kg/Km) Diameter (mm) 1162 1562 1895 2280 1606 1964 2393 2898 1654 2199 2763 3876 2174 2937 3967 5166 2987 4036 5128 6795 3561 4829 6578 4258 6268 7967 5423 7390 9403 6736 9238 11898 7896 11136 14328 13778 18669 22.2 24.9 26.8 29.5 25.5 27.2 29.5 32.4 25.9 28.6 32.1 36.4 29.2 32.3 37.4 41.7 33.2 37.0 41.6 48.6 36.4 40.5 47.0 39.4 45.8 51.5 44.3 49.9 56.2 49.2 55.1 62.4 51.3 60.3 68.4 67.9 78.8 Gland Size (mm) Nylon Cleat Size 25 25 32 32 25 32 32 32 25 32 32 40 32 32 40 50S 32 40 50S 50 40 50S 50 40 50S 50 50S 50 63S 50 63S 63 50 63 75S 75S 90 0.9 1.0 1.1 1.2 1.1 1.1 1.2 1.4 1.1 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.8 2.0 1.6 1.6 2.0 1.6 2.0 TC9 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC10 TC11 TC11 TC14 Temperature limits: - 15 to + 90°C. *Bending radius: 8 x Overall Diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. also available in Brown, Blue, Green/Yellow. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at - 15 to + 90°C temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 17 Low voltage PvC Fixed Wiring & Mains Cables Mains caBles WitH aluMiniuM conductoRs PVc Solid plain aluminium sectoral conductors, XLPE insulated, PvC bedding, galvanised steel wire armour, PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size SAC4X25 SAC4X35 SAC4X50 SAC4X70 SAC4X95 SAC4X120 SAC4X150 SAC4X185 SAC4X240 SAC4X300 25 35 50 70 95 120 150 185 240 300 4 4 4 4 4 4 4 4 4 4 1235 1515 1686 2401 2905 3705 4550 5076 6104 7212 25.4 28.9 29.5 34.7 38.3 42.2 46.0 51.1 56.4 61.4 25 32 32 40 40 50S 50 50 63S 63 1.0 1.2 1.2 1.4 1.6 1.8 2.0 TC9 TC9 TC10 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 18 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables sinGle coRe non-aRMouRed Mains caBles PVc Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, PvC outer sheath Black. 600/1000 volts grade to BS7889/97. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) Stranding (mm) 6181X50 6181X70 6181X95 6181X120 6181X150 6181X185 6181X240 6181X300 6181X400 6181X500 6181X630 6181X800 6181X1000 50 70 95 120 150 185 240 300 400 500 630 800 1000 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.52 127/2.85 127/3.20 Weight Overall (Kg/Km) Diameter (mm) 520 720 985 1215 1515 1865 2415 3005 3810 4890 6355 8075 9860 13.5 15.5 17.5 19 21.5 23.5 26.5 29 32.5 37 42 46 53 Brass A2 Nylon A2 25 25 25 32 32 32 40 40 50S 50S 50 63S 63 25 25 25 32 32 32 40 40 50 50 63 - Nylon Trefoil Cleat Cleat Size 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.2 376AC04 1.4 376AC06 1.6 376AC09 1.8 376AC12 2.0 376AC15 TC9 376AC19 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown inner - Black outer. Should not be installed at temperatures below 0°C or above +60°C. FiXed WiRinG and Mains caBles Stranded plain annealed compacted circular copper conductors, XLPE insulated, PvC bedding, aluminium wire armoured, PvC outer sheath. Black. 600/100 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Stranding No. Of Weight Overall Gland Gland Nylon Size (mm) Cores (Kg/Km) Diameter Size cw Size Cleat 2 (mm ) (mm) Ali (mm) Brass Size A2 (mm) 6941AX50 50.0 6941AX70 70.0 6941AX95 95.0 6941AX120 120.0 6941AX150 150.0 6941AX185 185.0 6941AX240 240.0 6941AX300 300.0 6941AX400 400.0 6941AX500 500.0 6941AX630 630.0 6941AX800 800.0 6941AX1000 1000.0 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.2 127/2.52 127/2.85 127/3.2 1 1 1 1 1 1 1 1 1 1 1 1 1 638 891 1166 1412 1800 2200 2800 3400 4450 5550 7100 9200 11270 17.70 19.60 21.50 23.10 26.00 28.00 32.00 33.00 38.00 43.00 47.00 55.00 58.80 20 25 25 25 32 32 40 40 40 50S 50 63S 63S 25 32 32 32 40 40 50S 50S 50 63S 63S 75S 75S 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.4 1.6 1.8 2.0 TC9 TC10 Trefoil Cleat 376AC04 376AC06 376AC06 376AC10 376AC13 376AC15 376AC20 376AC22 Temperature limits: - 15 to + 90°C. *Bending radius: 6 x Overall Diameter. Core identification: Brown inner - Black outer Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 19 Low voltage PvC Fixed Wiring & Mains Cables Mains caBles FoR Mines & QuaRRies PVc Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 600/1000 volts grade generally to BS5467 and BC295. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores NCB3X10/1 NCB4X10/1 NCB3X16/1 NCB4X16/1 NCB3X25 NCB4X25 NCB3X35 NCB4X35 NCB3X50 NCB4X50 NCB3X70 NCB4X70 NCB3X95 NCB4X95 NCB3X120 NCB4X120 NCB3X150 NCB4X150 NCB3X185 NCB4X185 NCB3X240 NCB4X240 NCB3X300 NCB4X300 10 10 16 16 25 25 35 35 50 50 70 70 95 95 120 120 150 150 185 185 240 240 300 300 7/1.04 7/1.04 7/1.70 7/1.70 7/2.14 7/2.14 7/2.52 7/2.52 19/1.78 19/1.78 19/2.14 19/2.14 19/2.52 19/2.52 37/2.03 37/2.03 37/2.25 37/2.25 37/2.52 37/2.52 61/2.25 61/2.25 61/2.52 61/2.52 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 Weight Overall (Kg/Km) Diameter (mm) 896 1038 1205 1675 1550 1880 1940 2350 2360 2950 3120 4230 4310 5390 5160 6980 6610 8300 7920 10070 9930 12680 11970 15380 18.9 20.3 23.1 26.3 26.9 29.1 29.6 32.1 28.4 31.3 32.0 36.8 36.7 40.6 40.0 45.8 45.1 49.9 49.3 54.9 54.5 61.0 59.5 66.5 Gland Size (mm) Nylon Cleat Size 20 20 25 25 25 32 32 32 32 32 32 40 40 50S 50S 50S 50S 50 50 63S 63S 63 63 75S 0.8 0.8 1.0 1.1 1.1 1.2 1.2 1.4 1.2 1.4 1.4 1.6 1.6 1.6 1.6 2.0 1.8 2.0 2.0 TC9 TC9 TC10 TC10 TC11 Temperature limits: -15 to +70°C. *Bending radius: up to 16mm2 - 6 x overall diameter. over 16mm2 - 8 x overall diameter. Core identification: 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 20 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables eeMua133 contRol caBles PVc Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Cores white with black numbers. 600/1000 volts grade to BS5467 and EEMUA 133. Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC Code Conductor Stranding Size (mm) (mm2) EEMUA2X1/5 ESI EEMUA3X1/5 ESI EEMUA4X1/5 ESI EEMUA5X1/5 EEMUA7X1/5 EEMUA12X1/5 EEMUA19X1/5 EEMUA27X1/5 EEMUA37X1/5 EEMUA2X2/5 ESI EEMUA3X2/5 ESI EEMUA4X2/5 ESI EEMUA5X2/5 EEMUA7X2/5 EEMUA12X2/5 EEMUA19X2/5 EEMUA27X2/5 EEMUA37X2/5 EEMUA5X4 EEMUA7X4 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 No. Of Cores 2 3 4 5 7 12 19 27 37 2 3 4 5 7 12 19 27 37 5 7 Weight Overall (Kg/Km) Diameter (mm) 690 750 810 895 1072 1387 1686 2418 2850 800 870 950 1038 1180 1750 2450 3100 3720 1014 1110 15 15.5 16 16.8 17.7 22.3 24.8 30 32.7 16 16.5 17.5 18.4 20 24.5 29 33 36 20.6 21.5 Gland Size (mm) Nylon Cleat Size 20 20 20 20 20 25 25 32 32 20 20 20 20 20 25 32 32 40 20 25 0.6 0.7 0.7 0.7 0.7 0.9 1.0 1.2 1.4 0.7 0.7 0.7 0.8 0.8 1.0 1.2 1.4 1.6 0.9 0.9 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 21 Low voltage PvC Fixed Wiring & Mains Cables eeMua133 Mains caBles PVc Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC Code EEMUA2X1/5 EEMUA3X1/5 EEMUA4X1/5 EEMUA2X2/5 EEMUA3X2/5 EEMUA4X2/5 EEMUA2X4 EEMUA3X4 EEMUA4X4 EEMUA2X6 EEMUA3X6 EEMUA4X6 EEMUA2X10 EEMUA3X10 EEMUA4X10 EEMUA2X16 EEMUA3X16 EEMUA4X16 Conductor Stranding Size (mm) (mm2) 1.5 1.5 1.5 2.5 2.5 2.5 4.0 4.0 4.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 No. Of Cores 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 Weight Overall (Kg/Km) Diameter (mm) 690 750 810 800 870 950 920 1000 1110 1020 1150 1400 1250 1530 1720 1630 1880 2150 15 15.5 16 16 16.5 17.5 17.5 17.5 19 18 19 20.5 20 22 23 23 24 26 Gland Size (mm) Nylon Cleat Size 20 20 20 20 20 20 20 20 25 20 25 25 25 25 25 25 25 32 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.8 0.9 1.0 1.0 1.0 1.1 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 22 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables eeMua133 Mains caBles PVc Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC Code Conductor Stranding Size (mm) (mm2) EEMUA2X25 EEMUA3X25 EEMUA4X25 EEMUA2X35 EEMUA3X35 EEMUA4X35 EEMUA2X50 EEMUA3X50 EEMUA4X50 EEMUA2X70 EEMUA3X70 EEMUA4X70 EEMUA2X95 EEMUA3X95 EEMUA4X95 EEMUA2X120 EEMUA3X120 EEMUA4X120 EEMUA2X150 EEMUA3X150 EEMUA4X150 EEMUA2X185 EEMUA3X185 EEMUA4X185 EEMUA2X240 EEMUA3X240 EEMUA4X240 EEMUA2X300 EEMUA3X300 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 7/2.14 7/2.14 7/2.14 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 No. Of Cores 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size 2094 2740 3160 2868 3205 3840 2783 3655 4530 3566 4675 6175 4678 6180 7695 5641 7390 9730 6660 9300 11530 8457 10980 14160 10286 13815 17700 16519 21173 27.1 30 32 31.9 32 34.5 28.1 33.5 37 31.1 37.5 43 35.1 42.5 47 38.5 46 53 41.8 52 58.5 47.1 56.5 65 52.3 63 65.8 64.1 71.5 32 32 32 32 32 40 32 40 40 32 40 50S 40 50S 50 50S 50 63S 50S 50 63S 50 63S 63 50 63 75S 63 75S 1.1 1.2 1.4 1.4 1.4 1.4 1.2 1.6 1.6 1.4 1.6 1.8 1.4 1.8 2.0 1.6 2.0 TC9 1.8 TC9 TC10 2.0 TC9 TC11 TC9 TC10 TC11 TC11 TC12 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: 2 core - Brown, Blue 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 23 Low voltage PvC Fixed Wiring & Mains Cables Mains and contRol caBle non aRMouRed tYPe nYY-J Solid plain copper conductors, PVC insulated, PVC filler, PVC outer sheath. Black. 600/1000 volts grade to IEC60502-1 and VDE 0276-603. For installation indoors and outdoors as underground, or in cable ducts, installations with additional protection where mechanical damage is unexpected. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size NYY3X1/5 NYY4X1/5 NYY5X1/5 NYY2X2/5 NYY3X2/5 NYY4X2/5 NYY5X2/5 NYY3X4 NYY4X4 NYY5X4 NYY3X6 NYY4X6 NYY5X6 - 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 6.0 6.0 6.0 6.0 10.0 10.0 10.0 10 16 16 16 16 1/1.38 1/1.38 1/1.38 1/1.38 1/1.38 1/1.78 1/1.78 1/1.78 1/1.78 1/1.78 1/2.25 1/2.25 1/2.25 1/2.25 1/2.76 1/2.76 1/2.76 1/2.76 1/3.56 1/3.56 1/3.56 1/3.56 1/4.51 1/4.51 1/4.51 1/4.51 2 3 4 5 7 2 3 4 5 7 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 157 190 220 270 299 193 240 290 350 388 267 330 400 480 329 420 510 600 498 580 751 910 684 800 1057 1257 10.50 11.00 11.80 12.80 13.70 11.30 11.90 12.8 13.9 14.9 13 13.70 14.80 16.30 14.00 14.80 16.00 17.60 16.60 17.80 19.30 21.2 18.8 20.2 22 24.20 20s 20 20 20 25 20 20 20 25 25 20 25 25 25 25 25 25 25 25 25 32 32 25 32 32 32 0.5 0.5 0.5 0.6 0.6 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.9 0.8 0.9 0.9 1.0 Temperature limits: -30 to +70°C. Bending radius: 15 x overall diameter. Core identification 2 core - Brown, Blue. 3 core - Brown, Blue, Green/Yellow 4 core - Brown, Blue, Black, Green/Yellow 5 core - Brown, Blue, Black, Grey, Green/Yellow. Should not be installed at - 5 to + 70°C. Should not be installed at temperatures below - 5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 24 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Low voltage PvC Fixed Wiring & Mains Cables sinGle coRe non-aRMouRed catHodic PRotection caBles PVc Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer sheath, 600/1000 volts grade generally to BS5467 & IEC 60502. Colours Black/Black or Red/Red. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 6181X6 6181X10 6181X16 6181X25 6181X35 6181X50 6181X70 6181X95 6181X120 6181X150 6181X185 6 10 16 25 35 50 70 95 120 150 185 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 105 150 210 305 395 515 725 1230 1355 1695 2110 7.2 8.1 9.0 10.6 11.6 13.0 14.9 17.5 19.2 21.3 23.4 20/16 20/16 20S 20S 20 20 25 25 32 32 32 Temperature limits: -15 to +90°C. *Bending radius: 4 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Core identification Black inner – Black outer. Red inner – Red outer. sinGle coRe aRMouRed catHodic PRotection caBles PVc Plain annealed compacted circular copper conductor, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade generally to IEC 60502 & BS5467. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 6941X6 6941X10 6941X16 6941X25 6941X35 6941X50 6941X70 6941X95 6941X120 6941X150 6941X185 6 10 16 25 35 50 70 95 120 150 185 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 285 355 435 585 685 835 1080 1375 1685 2120 2505 11.5 12.5 13.5 15.0 16.0 17.5 19.5 21.6 23.4 26.4 28.9 20/16 20/16 20S 20S 20 20 20 25 25 25 32 Temperature limits: -15 to +90°C. *Bending radius: 4 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Core identification Brown inner - Black outer. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 25 Low voltage PvC Fixed Wiring & Mains Cables sPlit concentRic caBles PVc Plain annealed stranded copper phase conductor, XLPE insulated surrounded by a concentric layer of plain annealed solid copper neutral conductors. XLPE insulated and plain annealed solid strand bare copper earth conductors, PVC outer sheath. Black. 600/1000 volts grade to BS 7870. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 4 SPLITCON 6 SPLITCON 10 SPLITCON 16 SPLITCON 25 SPLITCON 35 SPLITCON 4 6 10 16 25 35 7/0.85 7/1.04 7/1.35 7/1.70 **7/2.14 7/2.52 206 281 394 583 843 1300 9.6 11.4 12.7 14.6 18.7 23.0 20S 20 20 25 32 40 Temperature limits: -15 to +90°C. **Stranding of neutral is the same as phase conductor except 25 sq mm which has 11 x 1.70mm. Core identification: Brown Live/Blue Neutral. Should not be installed at temperatures below 0°C or above +60°C. Also available in violet outer sheath in 6mm, 10mm, 16mm & 25mm. stRaiGHt concentRic caBles PVc Plain annealed stranded copper phase conductor, PVC insulated surrounded by a concentric layer of plain annealed solid copper neutral/earth conductors in concentric layer, PVC outer sheath. Black. 600/1000 volts grade to BS 7870 & ESI 09-7. Combined neutral and earth (CNE). CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 4 STRCON 6 STRCON 16 STRCON 25 STRCON 35 STRCON 4 6 16 25 35 7/0.85 7/1.04 7/1.70 7/2.14 7/2.25 180 230 440 600 850 9.0 10.0 12.0 15.0 16.0 20S 20S 20 25 25 Temperature limits: -15 to +70°C. Core identification: Brown Live. *Bending radius: 10 x overall diameter. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 26 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 3300v Mains Cable SECTION 2 3300v Mains Cables 3300v Mains Cables sinGle coRe aRMouRed Mains caBles 1900/3300V PVc Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, Aluminium wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2 ) Stranding (mm) 6941AX120/3 6941AX150/3 6941AX185/3 6941AX240/3 6941AX300/3 6941AX400/3 6941AX500/3 6941AX630/3 120 150 185 240 300 400 500 630 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.52 No. Of Weight Overall Gland Cores (Kg/Km) Diameter Size (mm) (mm) 1 1 1 1 1 1 1 1 1490 1870 2290 2880 3520 4520 5680 7120 23.2 26.3 28.7 31.4 34.1 38.9 42.8 47.3 25 32 32 40 40 50S 50S 50 Nylon Cleat Size 1.2 1.2 1.4 1.4 1.8 1.8 1.8 2.0 Trefoil Cleat 376AC04 376AC05 376AC07 376AC10 376AC12 376AC15 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: Brown inner/Black outer. Should not be installed at temperatures below 0°C or above +60°C. sinGle coRe aRMouRed Mains caBle 1900/3300V lsZH Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 1900/3300 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code Conductor Stranding Size (mm) (mm2 ) 6941AB120/3 6941AB150/3 6941AB185/3 6941AB240/3 6941AB300/3 6941AB400/3 6941AB500/3 6941AB630/3 120 150 185 240 300 400 500 630 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.52 No. Of Cores 1 1 1 1 1 1 1 1 Weight Overall (Kg/Km) Diameter (mm) 1490 1870 2290 2880 3520 4520 5680 7120 23.2 26.3 28.7 31.4 34.1 38.9 42.8 47.3 Gland Size (mm) 25 32 32 40 40 50S 50S 50 Nylon Trefoil Cleat Cleat Size 1.2 1.2 1.4 1.4 1.8 1.8 1.8 2 376AC04 376AC05 376AC07 376AC10 376AC12 376AC15 Temperature limits: -25 to +70°C. *Bending radius: 6 x overall diameter. Core identification: Brown inner/Black outer. Should not be installed at temperatures below 5°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 28 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 3300v Mains Cables 3 coRe Mains caBles 1900/3300V PVc Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332. CCC Code Conductor Stranding Size (mm) (mm2) XLPE3X16/3 XLPE3X25/3 XLPE3X35/3 XLPE3X50/3 XLPE3X70/3 XLPE3X95/3 XLPE3X120/3 XLPE3X150/3 XLPE3X185/3 XLPE3X240/3 XLPE3X300/3 XLPE3X400/3 16 25 35 50 70 95 120 150 185 240 300 400 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 No. Of Cores 3 3 3 3 3 3 3 3 3 3 3 3 Weight Overall (Kg/Km) Diameter (mm) 1600 2060 2330 3040 3800 4730 6070 7010 8270 10310 12300 14780 29.5 32.3 35.0 34.9 38.0 41.4 45.6 48.3 51.6 56.5 60.7 65.8 Gland Size (mm) Nylon Cleat Size 32 32 40 40 40 50S 50S 50 50 63S 63 75S 1.2 1.4 1.4 1.4 1.6 1.8 1.8 2.0 TC9 TC9 TC10 TC11 Temperature limits: -15 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. 3 coRe Mains caBles 1900/3300V lsZH Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 1900/3300 volts grade to BS6724. acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & a; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores LSF3X16/3 LSF3X25/3 LSF3X35/3 LSF3X50/3 LSF3X70/3 LSF3X95/3 LSF3X120/3 LSF3X150/3 LSF3X185/3 LSF3X240/3 LSF3X300/3 16 25 35 50 70 95 120 150 185 240 300 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 3 3 3 3 3 3 3 3 3 3 3 Weight Overall (Kg/Km) Diameter (mm) 1600 2060 2330 3040 3800 4730 6070 7010 8270 10310 12300 29.5 32.3 35.0 34.9 38.0 41.4 45.6 48.3 51.6 56.5 60.7 Gland Size (mm) Nylon Cleat Size 32 32 40 40 40 50S 50S 50 50 63S 63 1.2 1.4 1.4 1.4 1.6 1.8 1.8 2.0 TC9 TC9 TC10 Temperature limits: -25 to +90°C. *Bending radius: 8 x overall diameter. Core identification: Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 29 3300v Mains Cables Mains caBles FoR Mines & QuaRRies 1900/3300V Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase, PVC outer sheath. Black. 1900/3300 volts grade generally to BS5467 and BC295. Flame propagation to BS EN 60332. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores NCB3X16/3 NCB3X25/3 NCB3X35/3 NCB3X50/3 NCB3X70/3 NCB3X95/3 NCB3X120/3 NCB3X150/3 NCB3X185/3 NCB3X240/3 NCB3X300/3 16 25 35 50 70 95 120 150 185 240 300 7/1.70 19/1.35 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 3 3 3 3 3 3 3 3 3 3 3 Weight Overall (Kg/Km) Diameter (mm) 1600 2060 2330 3040 3800 4730 6070 7110 8270 10310 12300 29.5 32.3 35.0 34.9 38.0 41.4 45.6 48.3 51.6 56.5 60.7 Gland Size (mm) Nylon Cleat Size 32 32 40 40 40 50S 50S 50 50 63S 63 1.2 1.4 1.4 1.4 1.6 1.8 1.8 2.0 TC9 TC9 TC10 Temperature limits: -15 to +70°C. *Bending radius: up to 16mm2 - 6 x overall diameter. over 16mm2 - 8 x overall diameter. Core identification: 3 core - Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. eeMua133 Mains caBles 1900/3300V PVc Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467 and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C). CCC Code EEMUA3X25/3 EEMUA3X35/3 EEMUA3X50/3 EEMUA3X70/3 EEMUA3X95/3 EEMUA3X120/3 EEMUA3X150/3 EEMUA3X185/3 EEMUA3X240/3 EEMUA3X300/3 Conductor Size (mm2) 25 35 50 70 95 120 150 185 240 300 Stranding No. Of (mm) Cores 7/2.14 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 Weight Overall (Kg/Km) Diameter (mm) 3 3400 32.5 3 3560 38.4 3 4520 38.1 3 5550 41.4 3 6770 45.0 3 8390 49.4 3 9630 52.3 3 11270 55.8 3 13720 60.9 3 16380 65.3 Gland Size (mm) Nylon Cleat Size 32 40 40 50S 50S 50 50 63S 63 75S 1.4 1.6 1.6 1.8 2.0 2.0 TC9 TC9 TC10 TC11 Temperature limits: -15 to +90°C. *Bending radius: 12 x overall diameter. Core identification: Brown, Black, Grey. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 30 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. LSZH Fixed Wiring & Mains Cables SECTION 3 LSZH Fixed Wiring & Mains Cables LSZH Fixed Wiring & Mains Cables 6491B (Ho7Z-R) lsZH Stranded plain annealed compacted circular copper conductor, low smoke and zero halogen (LSZH) outer sheath. 450/750 volts grade to BS7211. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Brass A2 Nylon A2 6491B1/5 6491B2/5 6491B4 6491B6 6491B10 6491B16 6491B25 6491B35 6491B50 6491B70 6491B95 6491B120 6491B150 6491B185 6491B240 6491B300 6491B400 6491B500 6491B630 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 7/2.14 7/2.52 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.50 22 33 49 69 116 175 273 367 510 715 990 1230 1510 1900 2490 3050 3842 4900 6334 3 3.65 4.2 4.75 6.15 7.1 8.9 9.95 11.7 13.35 15.6 17.2 19.1 21.3 24.36 27.05 30.35 32.8 36.5 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 20 25 25 25 32 32 40 40 50S 50S 16 16 16 16 16 16 20 20 20 25 25 25 32 32 32 40 40 50 50 Temperature limits: -15 to +90°C. *Bending radius: up to 10mm2 - 3 x overall 10 to 25mm2 - 4 x overall diameter. Above 25mm2 - 6 x overall diameter. Standard colours available: 1.5mm2 & 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, White, Orange, Turquoise, violet, Pink. 4mm2 - 630mm2 - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 32 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. LSZH Fixed Wiring & Mains Cables suRFace WiRinG caBles lsZH 6181B Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed, Ref 6181B. 300/500 volts grade to BS7211. Brown/White or Grey/White. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6181B1 6181B1/5 6181B2/5 6181B4 6181B6 6181B10 6181B16 6181B25 6181B35 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 1/1.13 1/1.38 1/1.78 7/0.85 7/1.04 7/1.35 7/1.04 7/2.14 7/2.52 1 1 1 1 1 1 1 1 1 Weight Overall (Kg/Km) Diameter (mm) 28 34 49 75 99 155 225 340 440 4.5 5.1 6.0 6.8 7.4 8.8 10.5 12.5 13.5 Gland Ref Nylon Size Size 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 - 0.5 0.5 0.6 Temperature limits: -25 to +90°C. *Bending radius: up to 10mm2 - 3 x overall diameter. over 10mm2 - 4 x overall diameter. Should not be installed at temperatures below 0°C or above +40°C. suRFace WiRinG caBles lsZH 624*B Plain annealed compacted copper conductor, XLPE insulated, one, two or three cores laid flat with an uninsulated circuit protective conductor and (LSZH) sheathed. White. Ref 6241/2/3B 300/500V to BS7211 low smoke and zero halogen (LSZH). Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low smoke and zero halogen (LSZH). CCC Code Conductor Size (mm2) 6241B1/5BR 6241B1/5BR 6242B1WH 6242B1/5WH 6242B1/5BRBR 6242B2/5WH 6242B4WH 6242B6WH 6242B10WH 6242B16WH 6243B1WH 6243B1/5WH 6243B2/5WH 1.5 1.5 1.0 1.5 1.5 2.5 4.0 6.0 10.0 16.0 1.0 1.5 2.5 Stranding (mm) No.Of Cores CPC Size (mm2) Weight (Kg/Km) Overall Diameter (mm) 1/1.37 1/1.37 1/1.13 1/1.37 1/1.37 1/1.77 7/0.85 7/1.04 7/1.35 7/1.70 1/1.13 1/1.37 1/1.77 1 1 2 2 2 2 2 2 2 2 3 3 3 1.0 1.0 1.0 1.0 1.0 1.5 1.5 2.5 4.0 6.0 1.0 1.0 1.5 51 51 69 85 85 120 175 240 390 560 92 115 170 4.65 X 5.80 4.65 X 5.80 4.10 X 8.65 4.55 X 8.80 4.55 X 8.80 5.40 X 10.50 6.10 X 12.00 6.90 X 13.80 8.40 X 18.50 9.70 X 20.60 4.60 X 10.20 5.75 X 11.45 5.30 X 12.80 Temperature limits: -25 to +90°C. *Bending radius: Fixed = 3 x diameter Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 33 LSZH Fixed Wiring & Mains Cables Mains and contRol caBles lsZH Plain annealed stranded copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 607541), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code LSF2X1/5 LSF3X1/5 LSF4X1/5 LSF5X1/5 LSF7X1/5 LSF12X1/5 LSF19X1/5 LSF27X1/5 LSF37X1/5 LSF48X1/5 LSF2X2/5 LSF3X2/5 LSF4X2/5 LSF5X2/5 LSF7X2/5 LSF12X2/5 LSF19X2/5 LSF27X2/5 LSF37X2/5 LSF48X2/5 LSF2X4 LSF3X4 LSF4X4 LSF5X4 LSF7X4 LSF12X4 LSF19X4 LSF27X4 LSF2X6 LSF3X6 LSF4X6 LSF5X6 LSF7X6 LSF2X10 LSF3X10 LSF4X10 LSF5X10 LSF7X10 LSF2X16 LSF3X16 LSF4X16 LSF5X16 LSF7X16 Conductor Size (mm2) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 10.0 10.0 16.0 16.0 16.0 16.0 16.0 Stranding (mm) No. Of Cores 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 7/1.70 2 3 4 5 7 12 19 27 37 48 2 3 4 5 7 12 19 27 37 48 2 3 4 5 7 12 19 27 2 3 4 5 7 2 3 4 5 7 2 3 4 5 7 Weight Overall (Kg/Km) Diameter (mm) 260 295 350 362 398 680 885 1310 1590 1958 270 360 410 435 520 905 1360 1760 2185 3003 381 435 495 583 760 1266 1701 2347 405 490 670 823 1100 600 750 885 1106 1500 905 990 1195 1695 2150 11 11.2 12.5 12.9 13.7 18 20.6 25.1 27.5 31 12.2 12.8 13.5 14.7 15.6 21 25 30 33 37.3 13.1 13.7 14.8 16.35 18.2 24.24 27.61 32.3 14.1 14.8 17.3 18.39 21.9 16.1 17.9 19.3 20.91 25 19 20 22 25.19 28.1 Gland Size (mm) 20/16 20/16 20S 20S 20S 20 25 32 32 32 20S 20S 20S 20 20 25 32 32 40 40 20S 20S 20 20 20 25 32 40 20 20 20 20 25 20 20 25 25 25 25 25 25 25 32 Nylon Cleat Size 0.5 0.5 0.5 0.6 0.6 0.8 0.9 1.0 1.1 1.4 0.5 0.6 0.6 0.6 0.7 0.9 1.0 1.2 1.4 1.6 0.6 0.6 0.6 0.7 0.8 1.0 1.2 1.4 0.6 0.6 0.7 0.8 0.9 0.7 0.8 0.8 0.9 1.0 0.8 0.8 0.9 1.0 1.2 Temperature limits: -25 to +90°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above - Up to 6mm2 White with Black numbers. 5 - 10mm2 and 16mm2 - Brown, Black, Grey, Blue, Green/Yellow. 1.5 & 2.5 - 2,3,4 core also available in white numbered cores to ESI 09-6. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 34 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. LSZH Fixed Wiring & Mains Cables Mains caBles lsZH Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code LSF2X25 LSF3X25 LSF4X25 LSF5X25 LSF2X35 LSF3X35 LSF4X35 LSF5X35 LSF2X50 LSF3X50 LSF4X50 LSF5X50 LSF2X70 LSF3X70 LSF4X70 LSF5X70 LSF2X95 LSF3X95 LSF4X95 LSF5X95 LSF2X120 LSF3X120 LSF4X120 LSF5X120 LSF2X150 LSF3X150 LSF4X150 LSF5X150 LSF2X185 LSF3X185 LSF4X185 LSF5X185 LSF2X240 LSF3X240 LSF4X240 LSF2X300 LSF3X300 LSF4X300 LSF3X400 LSF4X400 Conductor Size (mm2) 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 120 150 150 150 150 185 185 185 185 240 240 240 300 300 300 400 400 Stranding (mm) 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 No. Of Cores 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 2 3 4 3 4 Weight Overall (Kg/Km) Diameter (mm) 1050 1500 1800 2200 1400 1800 2200 2800 1750 2250 2850 3850 2200 3000 4100 5100 3000 4150 5200 7700 3600 4950 6700 9030 4250 6300 7900 10752 5500 7650 9650 11765 6900 9650 12400 8200 11550 14800 14350 19300 20 23 25 29 22 26 28 33 25 28 31 38 28 32 37 43 32 37 40 52 35 40 46 56.7 37 45 49 64.31 43 49 55 64.6 48 56 62 50 59 66 65 75 Gland Size (mm) 25 25 32 32 25 32 32 40 32 32 32 40 32 32 40 50S 32 40 50S 50 40 50S 50 63S 40 50S 50 63 50S 50 63S 75S 50 63S 63 50 63 75S 75S 75 Nylon Cleat Size 0.8 1.0 1.0 1.2 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.6 1.2 1.4 1.6 1.8 1.4 1.6 1.6 TC9 1.4 1.6 2.0 TC9 1.6 1.8 2.0 TC11 1.8 2.0 TC9 TC11 2.0 TC9 TC10 2.0 TC10 TC11 TC11 TC12 Temperature limits: -25 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above +40°C. nB 5 coRe 95MM and aBoVe aRe ManuFactuRed to iec60502-1 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 35 LSZH Fixed Wiring & Mains Cables sinGle coRe non-aRMouRed Mains caBles lsZH Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code Conductor Size (mm2) 6181B50 6181B70 6181B95 6181B120 6181B150 6181B185 6181B240 6181B300 6181B400 6181B500 6181B630 6181B800 6181B1000 50 70 95 120 150 185 240 300 400 500 630 800 1000 Stranding Weight Overall Brass (mm) (Kg/Km) Diameter A2 (mm) 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.52 61/3.20 127/2.52 127/2.85 127/3.20 525 730 990 1230 1525 1885 2440 3045 3855 4950 6345 8140 9860 13 15.5 18 19.5 21.5 24 27 29.5 33 37.5 42 47.5 53 25 25 25 32 32 32 40 40 50S 50S 50 63S 63 Nylon A2 Nylon Cleat Size Trefoil Cleat 25 25 25 32 32 32 40 40 50 50 63 - 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.6 1.8 2.0 TC9 376AC04 376AC06 376AC09 376AC12 376AC15 376AC19 Temperature limits: -25 to +90°C. *Bending radius: 6 x overall diameter. Core identification: Brown inner/Black outer. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 36 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. LSZH Fixed Wiring & Mains Cables sinGle coRe aRMouRed Mains caBles lsZH Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH). CCC Code Conductor Stranding No. Of Weight Overall Gland Gland Nylon Size (mm) Cores (Kg/Km) Diameter Size Cw Size Cleat (mm) Ali Brass A2 Size (mm2) (mm) (mm) 6941AB50 50.0 6941AB70 70.0 6941AB95 95.0 6941AB120 120.0 6941AB150 150.0 6941AB185 185.0 6941AB240 240.0 6941AB300 300.0 6941AB400 400.0 6941AB500 500.0 6941AB630 630.0 6941AB800 800.0 6941AB1000 1000.0 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.2 127/2.52 127/2.85 127/3.2 1 1 1 1 1 1 1 1 1 1 1 1 1 638 891 1166 1412 1800 2200 2800 3400 4450 5550 7100 9200 11270 17.70 19.60 21.50 23.10 26.00 28.00 32.00 33.00 38.00 43.00 47.00 55.00 58.80 20 25 25 25 32 32 40 40 40 50S 50 63S 63S 25 32 32 32 40 40 50S 50S 50 63S 63S 75S 75S Trefoil Cleat 0.7 0.8 0.9 1.0 1.1 1.2 376AC04 1.4 376AC06 1.4 376AC06 1.6 376AC10 1.8 376AC13 2.0 376AC15 TC9 376AC20 TC10 376AC22 Temperature limits: - 25 to + 90°C. *Bending radius: 6 x Overall Diameter. Core identification: Brown inner - Black outer. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 37 LSZH Fixed Wiring & Mains Cables scReened FiXed WiRinG and Mains caBles to Bs 8436 Plain annealed stranded copper, XLPE insulated, tinned annealed stranded copper earth wire, bonded aluminium tube applied longitudinally, low smoke and zero halogen (LSZH) outer sheath, to BS EN 50267-1:1998 and BS EN 50268-2:2000, UV Stable. 600/1000v to BS8436, White. Acid gas emissions to BS EN 50267-2-1, smoke emissions to BS EN 50268-2 and flame retardant to BS EN 60332-1-2 (IEC 60332-1-1). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores CSX2X1WH CSX3X1WH CSX4X1WH CSX2X1/5WH CSX3X1/5WH CSX4X1/5WH CSX2X2/5WH CSX3X2/5WH CSX4X2/5WH CSX2X4WH CSX3X4WH CSX4X4WH CSX2X6WH CSX3X6WH CSX4X6WH CSX2X10WH 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 4 4 4 6 6 6 10 7/0.44 7/0.44 7/0.44 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.35 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 Weight Overall (Kg/Km) Diameter (mm) 85 105 130 106 140 158 135 182 259 206 265 320 258 328 450 413 8.60 9.40 10.00 9.80 10.40 11.30 10.80 11.10 12.60 11.50 13.10 13.90 13.10 14.20 14.90 16.1 1 Hole Clip Ref Gland Ref RCHL34 RCHL37 RCHL37 RCHL37 RCHL40 RCHL43 RCHL43 RCHL43 RCHL47 RCHL43 RCHL51 RCHL54 RCHL51 RCHL54 RCHL59 RCHL63 20SA2 20SA2 20A2 20A2 20A2 20A2 20A2 20A2 20A2 20A2 25A2 25A2 25A2 25A2 25A2 25A2 Minimum installation temperature: -10°C. Maximum continuous conductors operating temperature: +90°C. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Solid cores available on request. Different sheath and core colours available on request. 10mm2 and 16mm2 available on request. Also available in 300/500 volt rating. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 38 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Medium voltage 11000v & Above SECTION 4 Medium voltage 11000v & Above Medium voltage 11000v & Above sinGle coRe aRMouRed Mains caBles PVc 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, copper tape screen, PVC bedding, aluminium wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter Size Nylon Cleat Size Trefoil Cleat 10001 10002 10003 10004 10005 10006 10007 10008 10009 10010 1 001 1 50 70 95 120 150 185 240 300 400 500 630 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61/3.20 127/2.52 1 1 1 1 1 1 1 1 1 1 1 1200 1461 1761 2049 2451 2848 3470 4103 4995 6320 7840 28.7 30.5 32.2 33.8 36.2 37.9 40.4 42.6 45.6 50 54 12 14 14 14 16 16 16 18 18 20 TC9 376AC04 376AC05 376AC06 376AC07 376AC08 376AC09 376AC11 376AC12 376AC14 376AC17 376AC19 Temperature limits: up to 90°C. *Bending radius: 12 x overall diameter. Core identification: Brown. Should not be installed at temperatures below 0°C or above +60°C. 3 coRe Mains caBles PVc 11000V Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code 11Kv XLPE3X25RD 11Kv XLPE3X35RD 11Kv XLPE3X50RD 11Kv XLPE3X70RD 11Kv XLPE3X95RD 11Kv XLPE3X120RD 11Kv XLPE3X150RD 11Kv XLPE3X185RD 11Kv XLPE3X240RD 11Kv XLPE3X300RD 11Kv XLPE3X400RD Conductor Stranding Size (mm) (mm2) 25 35 50 70 95 120 150 185 240 300 400 7/2/14 19/1/53 19/1/78 19/2/14 19/2/52 37/2/03 37/2/25 37/2/52 61/2/25 61/2/52 61/2/85 No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size 3 3 3 3 3 3 3 3 3 3 3 4300 4491 5105 6019 7148 8199 9274 10706 13740 16051 19095 48.4 50.5 53.3 56.9 61 64.6 67.8 71.9 78.8 84.1 90.3 2.0 2.0 TC9 TC9 TC10 TC11 TC11 TC12 TC14 TC14 TC15 Temperature limits: up to 90°C. *Bending radius: 12 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 40 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Medium voltage 11000v & Above 3 coRe Mains caBles PVc 11000V Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, PVC bedding (extruded), galvanised steel wire armour, PVC outer sheath. Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size 10115RD 10116RD 10117RD 10118RD 10119RD 10120RD 95 120 150 185 240 300 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 3 3 3 3 3 3 5800 6400 7000 7800 9800 11000 62.6 66.6 68.6 74.1 81.2 86.8 TC10 TC11 TC11 TC12 TC14 TC15 Temperature limits: up to 90°C. *Bending radius: 13 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C or above +60°C. tRiPleX caBles 11000V Solid or stranded aluminium conductor, XLPE insulated, copper wire screen (35mm2). MDPE outer sheath. Red. 6350/11000 volts grade to BS7870. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code Conductor Size (mm2) 11KvTRIP3X70AL 70 11KvTRIP3X70AL 70 11KvTRIP3X95AL 95 11KvTRIP3X95AL 95 11KvTRIP3X185AL 185 11KvTRIP3X185AL 185 11KvTRIP3X300AL 300 11KvTRIP3X300AL 300 Conductor Type Nominal Conductor Diameter (mm) SOLID STRANDED SOLID STRANDED SOLID STRANDED SOLID STRANDED 9.30 9.80 10.70 12.16 14.90 15.80 19.00 20.50 No. Of Cores Weight (Kg/Km) Diameter In Triplex Formation 3 3 3 3 3 3 3 3 2763 2650 3055 2901 4095 4060 5374 5360 57.4 58.3 60.8 57.83 70.5 72.5 80.4 81.4 Temperature limits: -15 to +90°C. *Bending radius: 15 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 41 Medium voltage 11000v & Above PaPeR insulated Mains caBles PVc 11000V COPPER CONDUCTOR Plain annealed copper conductors, paper insulated, paper belted, semi-conducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size PILC3X25RD PILC3X35RD PILC3X50RD PILC3X70RD PILC3X95RD PILC3X120RD PILC3X150RD PILC3X185RD PILC3X240RD PILC3X300RD PILC3X400RD 25 35 50 70 95 120 150 185 240 300 400 7/2.14 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 3 3 3 3 3 3 3 3 3 3 3 5230 5890 6620 7820 9240 10400 11770 13550 16390 19870 23700 43.6 42.3 45.6 49.7 53.3 56.2 59.2 62.8 67.8 73.6 79.4 1.8 2.0 2.0 2.0 TC9 TC9 TC10 TC10 TC11 TC12 TC14 Temperature limits: up to 65°C. *Bending radius: 13 x overall diameter. Core identification: White printed numbers on insulating papers. Should not be installed at temperatures below 0°C or above +60°C. ALUMINIUM CONDUCTOR Plain aluminium stranded conductors, paper insulated, paper belted, semi-conducting carbon paper tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332. Red outer sheath can be prone to fading when exposed to U.V rays. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size 10100RD 10103RD 10105RD 95 185 300 19/2.52 37/2.52 61/2.52 3 3 3 7115 9521 13403 53.2 63.5 71.5 TC9 TC11 TC12 Temperature limits: up to 65°C. *Bending radius: 13 x overall diameter. Core identification: White printed numbers on insulating papers. Should not be installed at temperatures below 0°C or above +60°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 42 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Medium voltage 11000v & Above sinGle coRe aRMouRed Mains caBles lsZH 11000V Stranded plain annealed compacted circular copper conductor, XLPE insulated, semi-conducting tape insulated, copper tape screen, low smoke and zero halogen (LSZH) bedding, aluminium wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V resistant qualities, red outer sheath cables are not recommended for outdoor installation. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size Trefoil Cleat 10050 10051 10052 10053 10054 10055 10056 10057 10058 10059 10060 50 70 95 120 150 185 240 300 400 500 630 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 61/2.85 61X3.20 127X2.52 1 1 1 1 1 1 1 1 1 1 1 1200 1461 1761 2049 2451 2848 3470 4103 4995 6320 7840 28.7 30.5 32.2 33.8 36.2 37.9 40.4 42.6 45.6 50 54 12 14 14 14 16 16 16 18 18 20 TC9 376AC04 376AC05 376AC06 376AC07 376AC08 376AC09 376AC1 1 376AC12 376AC14 376AC17 376AC19 Temperature limits: up to 90°C. *Bending radius: 15 x overall diameter. Core identification: Brown. Should not be installed at temperatures below 0°C or above +40°C. 3 coRe Mains caBles lsZH 11000V Stranded plain annealed compacted circular copper conductors, XLPE insulated, semi-conducting tape insulated, each core copper tape screened, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Nylon Cleat Size 10302RD 10304RD 10306RD 10308RD 10310RD 10312RD 10314RD 10316RD 10318RD 10320RD 35 50 70 95 120 150 185 240 300 400 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 70/3.15 3 3 3 3 3 3 3 3 3 3 4501 5117 6032 7163 8216 9292 10726 13763 16077 19124 50.5 53.3 56.9 61 64.6 67.8 71.9 78.8 84.1 90.3 TC9 TC9 TC9 TC10 TC11 TC11 TC12 TC14 TC14 TC15 Temperature limits: - 15 to + 70°C *Bending radius: 12 x overall diameter. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 43 Medium voltage 11000v & Above tHRee coRe Mains caBles 22KV and 33KV Compacted circular stranded annealed copper conductor, extruded semi-conductive conductor screen, XLPE insulated, extruded strippable semi-conductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 12700/22000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 22KvXLPE3X95RD 95.0 19/2.52 3 8820 70.30 Temperature limits: - 15 to + 90°C. *Bending radius: 12 x overall diameter. Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C or above +40°C. Compacted circular stranded annealed copper conductor, extruded semi-conductive conductor screen, XLPE insulated, extruded strippable semi-conductive insulation screen helically overlapped copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 19000/33000 volts grade to BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for outdoor installation. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 33KvLSF3X95RD 33KvLSF3X185RD 95.0 185.0 19/2.52 37/2.52 3 3 12020 20000 85.30 96.00 Temperature limits: - 15 to + 90°C. *Bending radius: 12 x overall diameter Core identification: Brown, Black, Grey tapes. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 44 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. High voltage 33000v Service And Windfarm Cables SECTION 5 High voltage 33000v Service And Windfarm Cables High voltage 33000v Service And Windfarm Cables sinGle coRe Mains caBle MdPe 33000V WindFaRM caBle Round stranded compacted aluminium conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape separator, extruded black MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 33Kv1X70AL 33Kv1X95AL 33Kv1X120AL 33Kv1X150AL 33Kv1X185AL 33Kv1X240AL 33Kv1X300AL 33Kv1X400AL 33Kv1X500AL 33Kv1X630AL 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 1 9/2 .1 19/2.47 35/2.04 35/2.27 35/2.54 35/2.91 35/3.25 56/2.91 56/3.3 56/3.75 1 1 1 1 1 1 1 1 1 1 1339 1467 1584 1720 1881 2130 2381 2723 3146 3675 36.70 38.40 39.80 41.30 43.00 45.50 47.80 50.80 54.30 58.90 Rated voltage Uo/U 19/33 kv Max operating voltage 36 kv Test voltage 75 kv Partial discharge level with voltage 2Uo kv max. 5pC Max. perm conductor temperature 90°C Max. perm operating temperature 130°C Short circuit temperature 250°C *Minimum bending radius 12 x overall diameter sinGle coRe Mains caBle MdPe 33000V seRVice caBle Round stranded compacted copper conductor, inner semi-conductive layer XLPE insulated, outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape metallic screen (35mm2), polyester tape/water blocking swelling tape separator, extruded black MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 33KvCU1X70BK 33KvCU1X95BK 33KvCU1X120BK 33KvCU1X150BK 33KvCU1X185BK 33KvCU1X240BK 33KvCU1X300BK 33KvCU1X400BK 33KvCU1X500BK 33KvCU1X630BK 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 500.0 630.0 1 9/2.1 1 19/2.48 35/2.05 35/2.28 35/2.55 35/2.92 35/3.28 56/2.93 56/3.32 56/3.77 1 1 1 1 1 1 1 1 1 1 1751 2043 2309 2614 2997 3596 4225 5069 6156 7570 36.50 38.20 39.60 41.20 42.90 45.40 47.80 50.60 53.90 57.60 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 46 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Fire Protection, Alarm & Security Cables SECTION 6 Fire Protection, Alarm & Security Cables Fire Protection, Alarm & Security Cables FiRePRooF caBles - MineRal insulated Solid plain annealed copper conductors, magnesium oxide insulated, solid copper sheath to BS6207, IEC 331 and BS 6387 CWZ. Available in the following options: (a)Light Duty = 500 volts grade Heavy Duty = 1000 volts grade (b)Outer sheath finishes, bare copper, PVC or LSZH (c)Outer sheath colours. Orange, Red, White or Black. Size Ref. Bare (Kg/Km) Sheathed (Kg/Km) Overall Diameter Bare (mm) Overall Diameter Sheathed (mm) Gland For Use With Rps Seals 2L1.0 2L1.5 2L2.5 2L4.0 3L1.0 3L1.5 3L2.5 4L1.0 4L1.5 4L2.5 7L1.5 7L2.5 1H6.0 1H10 1H16 1H25 1H35 1H50 1H70 1H95 1H120 1H150 1H240 2H1.5 2H2.5 2H4.0 2H6.0 2H10 2H16 2H25 3H1.5 3H2.5 3H4.0 3H6.0 3H10 3H16 3H25 4H1.5 4H2.5 4H4.0 4H6.0 4H10 4H16 4H25 7H1.5 7H2.5 12H2.5 19H1.5 104.0 136.0 187.0 248.0 136.0 176.0 223.0 162.0 203.0 277.0 295.0 411.0 173.0 240 326 457 585 758 1016 1324 1612 1949 3050 237 276 355 446 619 850 1178 254 323 415 526 754 1034 1444 305 384 507 644 911 1286 1805 432 559 911 992 125.00 159.00 213.00 282.00 159.00 201.00 256.00 187.00 230.00 313 332 454 213 273 361 499 632 810 1075 1413 1709 2055 3213 272 314 397 493 673 912 1277 290 364 460 575 812 1124 1549.00 345.00 428.00 556.00 698.00 974.00 1386.00 1947.00 479.00 611.00 1001.00 1088.00 5.1 5.7 6.6 7.7 5.8 6.4 7.3 6.3 7 8.1 8.4 9.7 6.4 7.3 8.3 9.6 10.7 12.1 13.7 15.4 16.8 18.4 23.3 7.9 8.7 9.8 10.9 12.7 14.7 17.1 8.3 9.3 10.4 11.5 13.6 15.6 18.2 9.1 10.1 11.4 12.7 14.8 17.3 20.1 10.8 12.1 15.6 16.6 6.6 7.2 8.1 9.4 7.3 7.9 9 7.8 8.5 9.8 10.1 11.4 7.7 9 10 11.3 12.4 13.8 15.4 17.7 19.1 20.7 26.1 9.6 10.4 11.5 12.6 14.4 16.4 19.4 10 11 12.1 13.2 15.3 17.9 20.5 10.8 11.8 13..1 14.4 16.5 19.6 22.9 12.5 13.8 17.9 18.9 20 20 20 20 20 20 20 20 20 20 25 25 20 20 20 20 20 25 25 25 32 32 40 20 20 20 20 25 25 32 20 20 20 25 25 25 40 20 20 25 25 25 32 40 25 25 32 40 Single Hole Clip Reference Bare Sheathed 20 22 26 30 22 24 28 24 28 32 32 37 34 28 32 37 40 47 54 59 63 71 88 30 34 37 43 47 54 67 32 37 40 43 54 59 71 37 40 43 47 54 67 79 43 47 59 63 26 28 32 37 28 30 34 30 34 37 40 43 34 34 37 43 47 54 59 67 75 79 101 37 40 43 47 54 63 75 37 43 47 51 59 71 79 43 47 51 54 63 75 88 47 54 71 71 Nominal Std Drum Lths (Mts) 500 500 500 500 500 500 500 500 500 500 380 285 650 510 400 275 222 170 190 155 135 110 67 500 500 500 500 500 112 80 500 500 500 184 130 100 70 500 500 195 144 110 89 60 245 195 148 112 Temperature limits: PvC sheath -20 to +70°C. LSF sheath -20 to +80°C. *Bending radius: 6 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 48 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Fire Protection, Alarm & Security Cables standaRd FiRe alaRM and secuRitY WiRinG caBles Plain annealed copper conductor, silicon rubber insulated aluminium/polyester tape screen, tinned annealed copper earth wire, low smoke zero halogen (LSZH) outer sheath. Red, White, Orange or Black. Fire resistant to IEC 331 and BS6387. Flame retardant to BS5839-1:2003 and IEC 60332-3 CAT CWZ, BS7629-1 1997. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores FP2X1 FP3X1 FP4X1 FP7X1 FP12X1 FP2X1/ 5 FP3X1/ 5 FP4X1/5 FP7X1/5 FP12X1/5 FP19X1/5 FP2X2/5 FP3X2/5 FP4X2/5 FP7X2/5 FP12X2/5 FP19X2/5 FP2X4 FP3X4 FP4X4 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.38 1/1.38 1/1.38 1/1.78 1/1.78 1/1.78 1/1.78 1/1.78 1/1.78 7/0.85 7/0.85 7/0.85 2+E 3+E 4+E 7+E 12+E 2+E 3+E 4+E 7+D 12+D 19+D 2+E 3+E 4+E 7+D 12+D 19+D 2+E 3+E 4+E Weight Overall Gland (Kg/Km) Diameter Size (mm) (mm) 90 110 135 170 270 110 130 160 230 365 540 160 200 250 285 470 720 260 315 380 7.5 8.0 8.8 10.5 13.7 8.0 8.4 9.5 11.3 15.2 17.8 9.0 10.5 11.7 13.7 17.9 21.4 11.3 12.1 13.3 20 20 20 20 25 20 20 20 20 25 25 20 20 20 20 25 32 20 25 25 1 Hole Clip Ref Gland Ref 28 30 34 40 54 32 34 37 43 59 67 34 40 43 54 67 79 43 47 54 251 251 251 252 254 251 251 251 252 254 254 252 252 252 252 254 255 252 254 254 E = Bare earth conductor. D = Drain wire. Temperature limits: -10 to +80°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 7 core and above - White with Black numbers. Should not be installed at temperatures below 0°C or above +40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 49 Fire Protection, Alarm & Security Cables enHanced FiRe alaRM and secuRitY WiRinG caBles Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced aluminium/polyester tape screen, tinned annealed copper earth wire, enhanced low smoke zero halogen outer sheath. Red or white. Manufactured to meet the Enhanced standard of BS5839-1 2002 +A2:2008 Clause 26.2e Enhanced and also the requirements of BS8434 - 2:2003 120 minutes and BS EN 50200 Class PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause 11 CWZ, halogen emissions to BS EN 50267-2-1:1999 and low smoke standard BS EN 61034-2:2005. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores ENH2X1/5 ENH3X1/5 ENH4X1/5 ENH2X2/5 ENH3X2/5 ENH4X2/5 ENH2x4 ENH3x4 ENH4x4 1.5 1.5 1.5 2.5 2.5 2.5 4.0 4.0 4.0 1/1.38 1/1.38 1/1.38 1/1.78 1/1.78 1/1.78 7/0.85 7/0.85 7/0.85 2+E 3+E 4+E 2+E 3+E 4+E 2+E 3+E 4+E Weight Overall Gland 1 Hole (Kg/Km) Diameter Size Clip Ref (mm) (mm) 110 130 160 160 200 250 260 315 380 8.0 8.4 9.5 9.0 10.5 11.7 11.3 12.1 13.3 20 20 20 20 20 20 20 25 25 32 34 37 34 40 43 43 47 51 Gland Ref 251 251 251 252 252 252 252 254 254 E = Bare earth conductor. Temperature limits: -40 to +90°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above +40°C. FiRePRooF caBles - sinGles Plain annealed copper conductor, mica fire resistant tape, low smoke zero halogen (LSZH) insulation. 600/1000 volts grade. Fire resistant to IEC 331 and BS6387, CWZ when tested in steel conduit. Manufactured to meet the following standards - acid gas emission to BS EN 50267, flame retardant to BS EN 60332-1-2 and smoke emission to BS7211. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 6491F1/5 6491F2/5 6491F4 6491F6 6491F10 6491F16 1.5 2.5 4.0 6.0 10.0 16.0 7/0.53 7/0.67 7/0.85 7/1.04 7/1.35 7/1.70 1 1 1 1 1 1 32 43 55 85 146 198 3.30 3.75 4.30 5.00 6.80 8.00 Temperature limits: - 40 to + 90°C. *Bending radius: 8 x Overall Diameter. Standard colours available: Brown, Blue, Grey, Black, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 50 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Fire Protection, Alarm & Security Cables FiRePRooF Mains and contRol caBles lsZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke & zero halogen (LSZH) outer sheath. Black. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2 / BS6387 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). CCC Code 6942F1/5 6943F1/5 6944F1/5 6947F1/5 6940/12F1/5 6940/19F1/5 6940/27F1/5 6940/37F1/5 6942F2/5 6943F2/5 6944F2/5 6947F2/5 6940/12F2/5 6940/19F2/5 6940/27F2/5 6940/37F2/5 6942F4 6943F4 6944F4 6945F4 6947F4 6942F6 6943F6 6944F6 6945F6 6942F10 6943F10 6944F10 6945F10 6942F16 6943F16 6944F16 6945F16 Conductor Stranding Size (mm) (mm2) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 6 6 6 6 10 10 10 10 16 16 16 16 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 No. Of Cores 2 3 4 7 12 19 27 37 2 3 4 7 12 19 27 37 2 3 4 5 7 2 3 4 5 2 3 4 5 2 3 4 5 Weight Outside (Kg/Km) Diameter (mm) 295 324 367 463 791 1030 1534 1849 352 392 454 584 1003 1525 1990 2435 424 478 556 725 852 504 573 783 865 620 868 1029 1222 954 1136 1367 1812 12.00 12.50 13.30 15.30 20.00 22.90 27.90 30.70 13.10 13.70 14.70 17.00 22.50 27.00 31.60 34.80 14.10 14.80 16.00 18.12 19.50 15.20 16.00 18.20 19.65 16.90 18.50 20.00 22.64 19.50 20.80 22.50 26.55 Gland Size (mm) Nylon Cleat Size 20/16 20/16 20S 20S 25 25 32 32 20S 20S 20S 20 25 32 32 40 20S 20S 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 0.5 0.6 0.6 0.7 0.8 1.0 1.2 1.4 0.6 0.6 0.6 0.7 0.9 1.1 1.4 1.4 0.6 0.6 0.7 0.8 0.8 0.7 0.7 0.8 0.8 0.7 0.8 0.8 0.9 0.8 0.9 0.9 1.1 Temperature limits: -40 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core and above 4mm2 and 6mm2 - White with Black numbers. 5 core - 10mm2 and 16mm2 Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 51 Fire Protection, Alarm & Security Cables FiRePRooF Mains caBles lsZH Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke, zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke, zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade. Fire resistant to BS6387/BS7846 F2 & CWZ. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores FP2X25 FP3X25 FP4X25 FP5X25 FP2X35 FP3X35 FP4X35 FP2X50 FP3X50 FP4X50 FP2X70 FP3X70 FP4X70 FP2X95 FP3X95 FP4X95 FP2X120 FP3X120 FP4X120 FP2X150 FP3X150 FP4X150 FP2X185 FP3X185 FP4X185 FP2X240 FP3X240 FP4X240 FP2X300 FP3X300 FP4X300 FP3X400 FP4X400 25 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 400 7/2.14 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 2 3 4 5 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 Weight Overall (Kg/Km) Diameter (mm) 1100 1800 2150 2700 1550 2200 2650 1850 2450 3100 2450 3200 4400 3350 4450 5650 3900 5300 7250 4650 6700 8550 5950 8050 10300 7350 9950 12900 8700 12050 15550 14800 20250 21.4 26.6 28.8 32 24.3 29.1 31.6 26.8 29.6 33.2 30 33.3 38.9 34.1 38.1 42.9 37.1 41.5 48.3 40.3 46.6 52.6 45.7 50.9 57.8 50 56.2 64.2 54.5 61.3 70 67.7 79.3 Gland Size (mm) Nylon Cleat Size 25 32 32 32 25 32 32 32 32 40 32 40 40 40 40 50S 40 50S 50 50S 50 50 50 50 63S 50 63S 63 63S 63 75S 75S 90 0.9 1.1 1.2 1.4 1.0 1.2 1.4 1.1 1.2 1.4 1.4 1.4 1.6 1.4 1.6 1.8 1.6 1.8 2.0 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC9 TC11 TC9 TC10 TC12 TC11 TC14 Temperature limits: -40 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. 5 core - Brown, Black, Grey, Blue, Green/Yellow. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 52 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Fire Protection, Alarm & Security Cables FiRePRooF Mains and contRol caBles lsZH - enHanced Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size FPE2X4 FPE3X4 FPE4X4 FPE2X6 FPE3X6 FPE4X6 FPE2X10 FPE3X10 FPE4X10 FPE2X16 FPE3X16 FPE4X16 4.0 4.0 4.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.7 7/1.7 7/1.7 2 3 4 2 3 4 2 3 4 2 3 4 871 966 959 1001 1087 1252 1060 1180 1350 1290 1460 1690 21.80 22.70 24.00 23.00 23.80 25.20 23.80 24.80 27.40 25.90 27.10 28.98 25 25 25 25 25 25 20 25 32 25 32 32 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.2 Temperature limits: - 40 to + 90°C. *Bending radius: 8 x Overall Diameter. Core identification: 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 53 Fire Protection, Alarm & Security Cables FiRePRooF Mains caBles lsZH - enHanced Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape, low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to IEC 61034, BS EN 50268. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size FPE2X25 FPE3X25 FPE4X25 FPE2X35 FPE3X35 FPE4X35 FPE2X50 FPE3X50 FPE4X50 FPE2X70 FPE3X70 FPE4X70 FPE2X95 FPE3X95 FPE4X95 FPE2X120 FPE3X120 FPE4X120 FPE2X150 FPE3X150 FPE4X150 FPE2X185 FPE3X185 FPE4X185 FPE2X240 FPE3X240 FPE4X240 FPE2X300 FPE3X300 FPE4X300 FPE3X400 FPE4X400 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120.0 150.0 150.0 150.0 185.0 185.0 185.0 240.0 240.0 240.0 300.0 300.0 300.0 400.0 400.0 7/2.14 7/2.14 7/2.14 7/2.52 7/2.52 7/2.52 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 19/2.52 19/2.52 19/2.52 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 37/2.52 61/2.25 61/2.25 61/2.25 61/2.52 61/2.52 61/2.52 61/2.85 61/2.85 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 1640 2070 2410 2130 2480 2920 2030 2630 3280 2580 3400 4570 3440 4550 5720 4050 5410 7270 4740 6800 8580 6050 8140 10300 7390 10040 12800 8760 12020 15410 14820 19910 29.00 31.10 33.40 31.90 33.50 36.10 29.90 33.20 37.10 33.30 37.00 45.50 37.20 41.20 46.40 39.90 44.40 51.20 43.10 49.30 55.70 48.10 53.70 60.80 52.40 58.80 66.50 56.50 63.50 72.10 70.10 81.30 32 32 40 32 40 40 32 40 40 40 40 50 40 50S 50 50S 50S 50 50S 50 63S 50 63S 63 50 63 75S 63S 63 75 75S 90 1.2 1.4 1.6 1.4 1.4 1.6 1.2 1.4 1.6 1.4 1.6 1.8 1.6 1.8 2.0 1.6 1.8 TC9 1.8 2.0 TC9 2.0 TC9 TC10 TC9 TC10 TC11 TC9 TC10 TC12 TC12 TC14 Temperature limits: - 40 to + 90°C. *Bending radius: 8 x Overall Diameter. Core identification: 2 core - Brown. Blue. 3 core - Brown, Black, Grey. 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 54 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber SECTION 7 Flexible Cables, PvC And Rubber Flexible Cables, PvC And Rubber PVc insulated FleXiBle coRds 218*Y - 318*Y Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath. Black or White. 300/500 volts grade to BS6500. (Harmonised code HO5VV-F). Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) **2182Y/5 **2182Y/75 **2183Y/5 **2183Y/75 3182Y/5 3183Y/5 3182Y/75 3183Y/75 3184Y/75 3185Y/75 3182Y1 3183Y1 3184Y1 3185Y1 3182Y1/5 3183Y1/5 3184Y1/5 3185Y1/5 3182Y2/5 3183Y2/5 3184Y2/5 3185Y2/5 0.5 0.75 0.5 0.75 0.5 0.5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 16/0.2 24/0.2 16/0.2 24/0.2 16/0.2 16/0.2 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 2 2 3 3 2 3 2 3 4 5 2 3 4 5 2 3 4 5 2 3 4 5 36 45 44 55 52 54 59 70 85 110 69 82 105 130 95 120 150 180 145 180 220 265 5.4 5.8 5.6 6.1 6.3 6.3 6.8 7.2 7.7 8.5 7.2 7.6 8.5 9.1 8.2 8.9 10.0 11.0 9.9 10.8 11.3 12.8 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20/16 20/16 20S 20S 20/16 20S 20S 20 20S 20S 20 20 Temperature limits: Fixed - -5 to +60°C. Flexing - +5 to +60°C. *Bending radius: Fixed 2 x overall diameter. Flexing 6 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Should not be installed at temperatures below 0°C. **Light flexible cords 300/300 volts grade Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 56 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber PVc insulated FleXiBle coRds 309*Y Plain annealed flexible copper conductors heat resisting PVC outer sheath. White 300/500 volts grade to BS6141. Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 3092Y/5 3093Y/5 3094Y/5 3092Y/75 3093Y/75 3094Y/75 3095Y/75 3092Y1 3093Y1 3094Y1 3092Y1/5 3093Y1/5 3094Y1/5 3092Y2/5 3093Y2/5 3094Y2/5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 2 3 4 2 3 4 5 2 3 4 2 3 4 2 3 4 46 66 70 56 68 85 104 65 77 100 80 100 130 135 150 195 6.3 6.5 7.2 6.8 7.2 7.7 8.5 7.2 7.6 8.5 8.2 8.9 10.0 10.0 10.8 11.8 20/16 20/16 20/16 20S 20S 20S 20S 20S 20S 20S 20S 20S 20 20S 20 20 Temperature limits: Fixed - -5 to +90°C. Flexing - +5 to +90°C. *Bending radius: Fixed - 2 x overall diameter. Flexing - 6 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow. Should not be installed at temperatures below 0°C. aRctic GRade FleXiBle coRds Plain annealed flexible copper conductors, low temperature PVC insulation, low temperature PVC outer sheath. Blue or Yellow. 300/500 volts grade to BS7919 table 44 and BS6500. Flame propagation to BS EN 50265. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 3183AG1/5 3184AG1/5 3183AG2/5 3184AG2/5 3183AG4 3183AG6 1.5 1.5 2.5 2.5 4 6 30/0.25 30/0.25 50/0.25 50/0.25 56/0.30 76/0.30 3 4 3 4 3 3 90 130 180 220 240 315 8.20 9.55 10.15 11.30 11.40 13.2 20S 20S 20S 20 20 20 Temperature limits: Flexing - -40 to +70°C. *Bending radius: 6 x overall diameter. Core identification: 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 57 Flexible Cables, PvC And Rubber ZeRo HaloGen FleXiBle coRds (Ho5 ZiZi-F) Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) outer sheath. Black or white. 300/500 volts grade (Generally to BS6500) Harmonised code HO5 ZIZI-F. Acid gas emission to BS EN 50267-2(IEC 60754-2), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332-1). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Temperature limits: -15 to +70°C. 3182B/75 3183B/75 3184B/75 3185B/75 3182B1 3183B1 3184B1 3185B1 3186B1 3182B1/5 3183B1/5 3184B1/5 3185B1/5 3186B1/5 3182B2/5 3183B2/5 3184B2/5 3185B2/5 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 24/0.2 24/0.2 24/0.2 24/0.2 32/0.2 32/0.2 32/0.2 32/0.2 32/0.2 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 2 3 4 5 2 3 4 5 6 2 3 4 5 6 2 3 4 5 59 70 85 110 69 82 105 130 136 95 120 150 180 201 145 180 220 265 6.8 7.2 7.7 8.5 7.2 7.6 8.5 9.1 9.8 8.2 8.9 10 11 10.1 9.9 10.8 11.3 12.8 20/16 20/16 20/16 20S 20/16 20/16 20S 20S 20S 20/16 20S 20S 20 20S 20S 20S 20 20 *Bending radius: Fixed 4x overall diameter Flexing 6x overall diameter Core identification: 2 core - Brown, Blue. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 6 core - Blue, Brown, Black, Red, White, Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 58 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber tYPe YY contRol caBles Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Temperature limits: -5 to +70°C. YY2X/75 YY3X/75 YY4X/75 YY5X/75 YY7X/75 YY12X/75 YY18X/75 YY25X/75 YY34X/75 YY50X/75 YY65X/75 YY2X1 YY3X1 YY4X1 YY5X1 YY7X1 YY12X1 YY18X1 YY25X1 YY34X1 YY41X1 YY50X1 YY65X1 YY2X1/5 YY3X1/5 YY4X1/5 YY5X1/5 YY7X1/5 YY8X1/5 YY10X1/5 YY12X1/5 YY18X1/5 YY25X1/5 YY34X1/5 YY50X1/5 YY65X1/5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 2 3 4 5 7 12 18 25 34 50 65 2 3 4 5 7 12 18 25 34 41 50 65 2 3 4 5 7 8 10 12 18 25 34 50 65 46 52 64 77 95 155 221 305 460 578 850 55 66 82 93 121 200 318 415 575 665 815 1055 69 87 110 124 176 230 265 290 424 565 775 1095 1390 5.6 5.7 6.2 7 7.3 9.5 11.1 13.2 16.7 18.4 23.5 6 6.1 6.7 7.5 8.1 11 12.7 15.5 18.3 19 21.3 25.6 6.6 7 7.6 8.1 9.2 11.2 12.4 13.1 14.8 18 21 24.2 28.8 20/16 20/16 20/16 20/16 20/16 20S 20 20 25 25 32 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 32 32 20/16 20/16 20/16 20S 20S 20 20 20 25 25 32 32 40 *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. Should not be installed at temperatures below -5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 59 Flexible Cables, PvC And Rubber tYPe YY contRol caBles Plain annealed flexible copper conductors, PVC insulated, PVC sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) YY2X2/5 YY3X2/5 YY4X2/5 YY5X2/5 YY7X2/5 YY8X2/5 YY12X2/5 YY18X2/5 YY25X2/5 YY34X2/5 YY3X4 YY4X4 YY5X4 YY7X4 YY3X6 YY4X6 YY5X6 YY7X6 YY3X10 YY4X10 YY5X10 YY3X16 YY4X16 YY5X16 YY3X25 YY4X25 YY5X25 YY4X35 YY5X35 YY4X50 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 25.0 25.0 25.0 35.0 35.0 50.0 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 396/0.40 2 3 4 5 7 8 12 18 25 34 3 4 5 7 3 4 5 7 3 4 5 3 4 5 3 4 5 4 5 4 106 126 159 178 272 350 403 597 885 1220 201 283 293 413 273 352 415 537 466 631 720 697 767 1151 930 1150 1679 1970 2206 2700 7.8 8.1 8.9 9.7 11.1 13.5 13.8 17.5 22 25.8 10.4 10.7 12.4 14 11.5 12.8 14.6 15.2 15.3 16.5 18.6 18.4 19.9 22.4 21.5 22.5 27.9 29 31.3 34 20/16 20S 20S 20S 20S 20 20 25 32 32 20S 20S 20 25 20 20 25 25 25 25 25 25 32 32 32 32 40 40 40 50S Temperature limits: -5 to +70°C. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. 7 core - Blue, Brown, Black, Grey, White, Red, Green/Yellow. Should not be installed at temperatures below -5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 60 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber tYPe sY contRol caBles Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) SY2X/75 SY3X/75 SY4X/75 SY5X/75 SY7X/75 SY12X/75 SY18X/75 SY25X/75 SY34X/75 SY2X1 SY3X1 SY4X1 SY5X1 SY7X1 SY12X1 SY18X1 SY25X1 SY34X1 SY50X1 SY2X1/5 SY3X1/5 SY4X1/5 SY5X1/5 SY7X1/5 SY12X1/5 SY18X1/5 SY25X1/5 SY34X1/5 SY50X1/5 SY2X2/5 SY3X2/5 SY4X2/5 SY5X2/5 SY7X2/5 SY12X2/5 SY18X2/5 SY25X2/5 SY34X2/5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 2 3 4 5 7 12 18 25 34 2 3 4 5 7 12 18 25 34 50 2 3 4 5 7 12 18 25 34 50 2 3 4 5 7 12 18 25 34 78 91 104 121 135 214 293 418 610 85 95 120 123 171 276 382 437 556 955 100 143 170 173 198 341 490 606 835 1046 177 190 240 247 327 502 740 1065 1126 7.1 7.6 8.3 8.9 9.5 11.9 13.2 13.7 19 7.7 8.2 9 9.2 10.1 12.9 15 17.9 20 23.7 8.2 8.6 9.3 10 10.7 13.8 16.4 19.2 21.6 23.8 9.8 9.9 10.8 11.5 13 16.9 19.8 23.2 24.3 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20 20/16 20/16 20/16 20/16 20/16 20S 20 20 20 25 20/16 20/16 20/16 20/16 20/16 20S 20 20 25 25 20/16 20/16 20/16 20S 20S 20 20 25 25 Temperature limits: -5 to +70°C. *Bending radius: Static - 10 x overall diameter. Flexing - 20 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Should not be installed at temperatures below -5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 61 Flexible Cables, PvC And Rubber tYPe sY contRol caBles Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and VDE 0250 class 5. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) SY3X4 SY4X4 SY5X4 SY7X4 SY3X6 SY4X6 SY5X6 SY7X6 SY3X10 SY4X10 SY5X10 SY3X16 SY4X16 SY5X16 SY4X25 SY5X25 SY4X35 SY5X35 SY4X50 SY4X70 SY4X95 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 16.0 25.0 25.0 35.0 35.0 50.0 70.0 95.0 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 276/0.40 276/0.40 396/0.40 356/0.50 485/0.50 3 4 5 7 3 4 5 7 3 4 5 3 4 5 4 5 4 5 4 4 4 323 354 392 486 343 458 572 640 563 776 855 813 900 1258 1597 2007 2046 2524 2888 4015 5176 12.2 13.4 15 16 13.4 14.6 16.7 18 17.3 19.1 21 20.5 22.4 25.2 28.2 31.2 31.3 34.3 37 41.2 47.8 20S 20S 20 20 20S 20S 20 20 20 20 25 25 25 25 32 32 40 40 40 50S 50 Temperature limits: -5 to +70°C. *Bending radius: Static - 10 x overall diameter. Flexing - 20 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Should not be installed at temperatures below -5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 62 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber tYPe cY contRol caBles Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned copper wire braid screen, PVC outer sheath. Grey. 300/500 volts grade generally to BS6500 and VDE 0250. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Brass A2 CY2X/5 CY3X/5 CY4X/5 CY5X/5 CY7X/5 CY2X/75 CY3X/75 CY4X/75 CY5X/75 CY7X/75 CY12X/75 CY18X/75 CY25X/75 CY2X1 CY3X1 CY4X1 CY5X1 CY7X1 CY12X1 CY18X1 CY25X1 CY34X1 CY2X1/5 CY3X1/5 CY4X1/5 CY5X1/5 CY7X1/5 CY12X1/5 CY18X1/5 CY25X1/5 CY34X1/5 CY42X1/5 CY2X2/5 CY3X2/5 CY4X2/5 CY5X2/5 CY7X2/5 CY12X2/5 CY2X4 CY3X4 CY4X4 CY5X4 CY4X6 CY4X10 CY4X16 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 6.0 10.0 16.0 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 80/0.40 126/0.40 2 3 4 5 7 2 3 4 5 7 12 18 25 2 3 4 5 7 12 18 25 34 2 3 4 5 7 12 18 25 34 42 2 3 4 5 7 12 2 3 4 5 4 4 4 41 50 66 79 102 43 52 68 80 103 161 238 316 53 64 84 100 125 209 308 420 650 61 78 104 128 159 281 396 534 720 1015 102 117 168 199 252 500 165 186 239 301 327 553 846 5.0 5.2 6.2 7.0 7.2 5.5 5.8 6.5 7.1 7.6 9.9 11.7 13.9 6.3 6.4 7.2 7.8 8.5 11.3 13.3 16.23 19.5 6.5 6.9 7.7 8.6 9.2 12.7 14.7 17.49 19.89 23.8 8 8.4 9.19 10.3 11.2 16.8 10.5 10.3 11.8 13 12.9 17.2 21 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20 20 20/16 20/16 20/16 20/16 20/16 20S 20 25 25 20/16 20/16 20/16 20S 20 25 25 25 32 25 20/16 20/16 20S 20S 20S 25 20S 20S 20S 20S 20S 25 32 Temperature limits: Static - -20 to +80°C. Flexing - -5 to +70°C. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Black with White numbers. 3 core and above - Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Should not be installed at temperatures below -5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 63 Flexible Cables, PvC And Rubber tYPe YY contRol caBles lsZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) YY2X/75LSF YY3X/75LSF YY4X/75LSF YY5X/75LSF YY7X/75LSF YY12X/75LSF YY2X1LSF YY3X1LSF YY4X1LSF YY5X1LSF YY2X1/5LSF YY3X1/5LSF YY4X1/5LSF YY5X1/5LSF YY7X1/5LSF YY12X1/5LSF YY18X1/5LSF YY25X1/5LSF YY34X1/5LSF YY2X2/5LSF YY3X2/5LSF YY4X2/5LSF YY5X2/5LSF YY7X2/5LSF YY3X4LSF YY4X4LSF YY5X4LSF YY7X4LSF YY3X6LSF YY4X6LSF YY5X6LSF YY3X10LSF YY4X10LSF YY5X10LSF YY3X16LSF YY4X16LSF YY3X25LSF 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4 6.0 6.0 6.0 10.0 10.0 10.0 16.0 16.0 25.0 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 24/0.2 32/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.3 56/0.3 56/0.3 84/0.30 84/0.3 84/0.30 80/0.40 80/0.4 80/0.40 126/0.4 126/0.4 196/0.40 2 3 4 5 7 12 2 3 4 5 2 3 4 5 7 12 18 25 34 2 3 4 5 7 3 4 5 7 3 4 5 3 4 5 3 4 3 46 52 64 77 95 155 55 66 82 93 69 87 110 124 176 290 424 565 775 106 126 159 178 272 201 283 293 413 273 352 415 466 631 720 697 767 930 5.6 5.7 6.2 7 7.3 9.5 6 6.1 6.7 7.5 6.6 7 7.6 8.1 9.2 13.1 14.8 18 21 7.8 8.1 8.9 9.7 11.1 10.4 10.7 12.4 14 11.5 12.8 14.6 15.3 16.5 18.6 18.4 19.9 21.5 20/16 20/16 20/16 20/16 20/16 20S 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 32 20/16 20S 20S 20S 20 20S 20S 20 25 20 20 25 25 25 25 25 32 32 tYPe cY contRol caBles lsZH Temperature limits: -5 to 70°C. *Bending radius: Static - 6 x Overall Diameter Flexible - 15 x Overall Diameter. Core identification: 2 Core - Black with White numbers. 3 Core and above Black with White numbers plus Green/Yellow. Also available with coloured cores as follows: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Blue, Brown, Black, Green/Yellow alternatively as per Cenelec HD 308 four core is available in an alternative core identification - brown, black, grey, green/yellow. 5 core - Blue, Brown, Black, Grey, Green/Yellow. Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) Should not be installed at insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen temperatures below -5°C. (LSZH) outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250. CCC Code Conductor Size (mm2) CY2X/75LSF CY3X/75LSF CY4X/75LSF CY5X/75LSF CY7X/75LSF CY2X1/5LSF CY3X1/5LSF CY4X1/5LSF CY5X1/5LSF CY12X1/5LSF CY18X1/5LSF CY25X1/5LSF CY34X1/5LSF 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 2 3 4 5 7 2 3 4 5 12 18 25 34 43 52 68 80 103 61 78 104 128 281 396 534 720 5.5 5.8 6.5 7.1 7.6 6.5 6.9 7.7 8.6 12.7 14.7 17.49 19.89 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 20/16 25 25 25 32 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 64 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber Temperature limits: - 5 to + 70°C tYPe sY contRol caBles lsZH Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Black. Bending radius: Static - 10 x overall diameter. 300/500 volts grade generally to BS6500 and VDE 0250 Flexing - 20 x overall diameter. CCC Code Conductor Size (mm2) Stranding (mm) No Of Cores Weight Kg/Km Overall Diameter (mm) Gland Size (mm) SY3X1/5LSF SY4X1/5LSF SY3X2/5LSF SY4X2/5LSF SY3X4LSF SY3X6LSF 1.5 1.5 2.5 2.5 4 6 30/0.25 30/0.25 50/0.25 50/0.25 56/0.3 84/0.30 3 4 3 4 3 3 143 170 190 240 323 343 8.6 9.3 9.9 10.8 12.2 13.4 20/16 20/16 20/16 20/16 20s 20s Core identification 3 core and above - black with white numbers plus green/yellow also available with coloured cores as follows: 3 core - Blue, Brown, Green/Yellow 4 core - Blue, Brown, Black, Green/Yellow alternatively as per cenelec HD308 four core is available in an alterative core identification - brown, black, grey, green/yellow. Should not be installed at temperatures below - 5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 65 Flexible Cables, PvC And Rubber tRi-Rated eQuiPMent WiRes Plain annealed stranded circular copper conductors, circular high temperature PVC outer sheath. UL & CSA approved also to BS6231. 600/1000 volts grade. Flame propagation to BS EN 50265 and IEC 60332-1. CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) TRI0/5 TRI/75 TRI1 TRI1/5 TRI2/5 TRI4 TRI6 TRI10 TRI16 TRI25 TRI35 TRI50 TRI70 TRI95 TRI120 BI150 BI185 BI240 BI300 BI400 0.5 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150 185 240 300 400 16/0.20 24/0.20 32/0.20 30/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 12 15 18 23 34 50 71 123 207 303 412 607 837 1079 1280 1619 1948 2518 3112 4051 2.7 2.9 3.1 3.3 3.7 4.3 4.9 6.3 9.0 10.4 11.9 14.7 16.8 18.8 19.9 22.9 24.1 28.6 32.2 36 20/16 20/16 20/16 20/16 20/16 20S 20S 20 25 25 25 32 32 32 40 50S 50 Temperature limits: -30 to +105°C. *Bending radius: 6 x Overall diameter. Standard colours available: 0.5mm2 - 2.5mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White, Orange, Pink, violet. 4.0mm2 - 16mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow, White. 25.0mm2 - 120mm2 - Brown, Black, Grey, Blue, Green/Yellow, Red, Yellow. 150mm2 - Black, Green/Yellow. 185mm2 - 400mm2 - Black. Should not be installed at temperatures below 0°C. 2491B/6701B lsZH FleXiBle sinGle coRes Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer sheath to BS7211. 0.75mm/1.0mm rated at 300/500 volts grade, harmonised code HO5Z-K. 1.5mm to 240mm rated at 450/750 volts grade, harmonised code HO7Z-K. Flame propagation to BS EN 50266-1:2001 (formerly BS4066:PT1). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) 2491B/75 2491B1 2491B1/5 2491B2/5 2491B4 2491B6 6701B10 6701B16 6701B25 6701B35 6701B50 6701B70 6701B95 6701B120 6701B150 6701B185 6701B240 0.75 1.0 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 24/0.20 32/0.20 30/0.25 50/0.25 56/0.25 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12 14 20 30 45 65 110 160 250 340 480 670 890 1140 1410 1710 2270 2.12 2.48 2.98 3.63 4.23 4.83 6.10 7.10 8.70 9.90 11.60 13.30 15.20 17.00 18.90 21.00 23.90 Temperature limits: - 15 to + 90°C *Bending radius: up to 35mm2 - 3 x Overall Diameter 50mm2 and above - 4 x Overall diameter. Standard colours available: 1.5mm to 6mm - Black, Blue, Brown, Grey, Orange, White, Red, Yellow, Green/Yellow. 10mm2 - 240mm2 - Black, Blue, Brown, Grey. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 66 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber solaR eneRGY caBles Electrolytic annealed tinned flexible copper conductor, halogen free thermosetting rubber insulation, type EI6 according to EN 50363-1 and table 4 of the TUV standard, halogen free thermosetting rubber outer sheath, type EM8 according to EN 50363-1 and table 4 of the TUV standard. Black. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) SOLAR1X1/5BK SOLAR1X2/5BK SOLAR1X4BK SOLAR1X6BK SOLAR1X10BK SOLAR1X16BK SOLAR1X25BK SOLAR1X35BK 1.5 2.5 4.0 6.0 10 16 25 35 29/0.25 48/0.25 48/0.3 72/0.3 126/0.3 116/0.4 180/0.4 260/0.4 1 1 1 1 1 1 1 1 40 49 66 86 132 188 294 390 4.90 5.35 6.00 6.55 7.60 8.60 10.80 11.90 Characteristics. Nominal voltage: AC: 0,6/1 kV; DC: 1,8 kV. Ambient temperature range: -40 °C to + 90 ºC. Maximum conductor temperature: 120 ºC. Maximum short-circuit temperature: 250 °C (maximum 5 s). *Minimum bending radius (fixed): 5 x cable Ø. No flame propagation: EN 60332-1-2 / IEC 60332-1-2. No fire propagation: EN 60332-3 / IEC 60332-3. Halogen free: according to EN 50267 / IEC 60754 HCl content < 0,5%. pH > 4,3. conductivity < 10 !S/mm. Smoke density: light transmittance > 60% (according to EN 61034/IEC 61034). sinGle coRe PVc FleXiBle Mains caBles Plain annealed flexible copper conductor, PVC insulated PVC sheathed, 450/750 volts, generally to BS6004 & IEC60502. Flame propagation to BS4066 PT1 & IEC332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 6381Y6 6381Y10 6381Y16 6381Y25 6381Y35 6381Y50 6381Y70 6381Y95 6381Y120 6381Y150 6381Y185 6381Y240 6381Y300 6381Y400 6.0 10.00 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 400.0 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 1 1 1 1 1 1 1 1 1 1 1 1 1 1 105 151 208 303 401 560 748 990 1233 1528 1857 2419 3032 3937 7.7 8.8 9.9 11.4 12.7 14.6 16.1 18.6 20.2 22.5 25.1 28.3 31.2 35.4 20/16 20S 20S 20 20 25 25 25 32 32 32 40 40 50S Temperature limits: -15 to +70°C. *Bending radius: Up to 50mm 3 x overall diameter. Over 70mm 5 x overall diameter. Standard core colours available: Black, grey, blue, brown, green/yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 67 Flexible Cables, PvC And Rubber FleXiBle Mains and contRol caBles ePR,csP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500. Black or White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code H07BN4-F. CCC Code Conductor Size (mm2) 3182TQ/75 3183TQ/75 3184TQ/75 3182TQ1 3183TQ1 3184TQ1 3181TQ1/5 3182TQ1/5 3183TQ1/5 3184TQ1/5 3185TQ1/5 3186TQ1/5 3187TQ1/5 3180/12TQ1/5 3180/16TQ1/5 3180/20TQ1/5 3180/27TQ1/5 3180/37TQ1/5 3181TQ2/5 3182TQ2/5 3183TQ2/5 3184TQ2/5 3185TQ2/5 3187TQ2/5 3180/12TQ2/5 3180/16TQ2/5 3180/20TQ2/5 3180/27TQ2/5 3180/37TQ2/5 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 Stranding (mm) No. Of Cores Weight (Kg/Km) 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 2 3 4 2 3 4 1 2 3 4 5 6 7 12 16 20 27 37 1 2 3 4 5 7 12 16 20 27 37 58 72 86 80 90 110 38 115 135 170 200 335 366 410 570 710 920 1260 41 160 195 245 300 424 600 780 1050 1390 1720 Mean Overall Diameter (mm) Lower Limit Upper Limit 5.7 6.2 6.8 6.1 6.5 7.1 5.7 7.6 8.0 9.0 11.2 13.4 14.6 17.6 19.8 21.4 25.3 29.0 6.3 9.0 9.6 10.7 13.3 17.2 20.6 23.8 26.4 30.1 35.0 7.4 8.1 8.8 8.0 8.5 9.3 7.1 9.8 10.4 11.6 14.4 17.2 18.2 22.4 24.3 26.7 30.0 34.2 7.9 11.6 12.4 13.8 17.0 21.0 26.2 28.4 31.2 35.4 40.9 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 68 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber FleXiBle Mains caBles ePR,csP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 502652-1). Harmonised code H07BN4-F. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) 6381TQ4 6382TQ4 6383TQ4 6384TQ4 6385TQ4 6387TQ4 6380/12TQ4 6381TQ6 6382TQ6 6383TQ6 6384TQ6 6385TQ6 6387TQ6 6388TQ6 6381TQ10 6382TQ10 6383TQ10 6384TQ10 6385TQ10 6381TQ16 6382TQ16 6383TQ16 6384TQ16 6385TQ16 4.0 4.0 4.0 4.0 4.0 4.0 4.0 6 6 6 6 6 6 6 10 10 10 10 10 16 16 16 16 16 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 126/0.40 126/0.40 1 2 3 4 5 7 12 1 2 3 4 5 7 8 1 2 3 4 5 1 2 3 4 5 105 275 335 420 515 773 1183 130 370 450 565 690 904 1040 200 690 835 1020 1240 275 910 1120 1380 1695 Mean Overall Diameter (mm) Lower Limit Upper Limit 7.2 11.8 12.7 14.0 15.6 19.8 24.4 7.9 13.1 14.1 15.7 17.5 21.6 25.2 9.5 17.7 19.1 20.9 22.9 10.8 20.2 21.8 23.8 26.4 9.0 15.1 16.2 17.9 19.9 24.4 30.9 9.8 16.8 18.0 20.0 22.9 26.9 29.6 11.9 22.6 24.2 26.5 29.1 13.4 25.7 27.6 30.1 33.3 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 6 x overall diameter. Flexing - 7 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 69 Flexible Cables, PvC And Rubber FleXiBle Mains caBles ePR,csP Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). Harmonised code H07BN4-F. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) 6381TQ25 6382TQ25 6383TQ25 6384TQ25 6385TQ25 6381TQ35 6382TQ35 6383TQ35 6384TQ35 6385TQ35 6381TQ50 6383TQ50 6384TQ50 6385TQ50 6381TQ70 6383TQ70 6384TQ70 6385TQ70 6381TQ95 6383TQ95 6384TQ95 6385TQ95 6381TQ120 6383TQ120 6384TQ120 6385TQ120 6381TQ150 6383TQ150 6384TQ150 6381TQ185 6383TQ185 6384TQ185 6381TQ240 6383TQ240 6384TQ240 6381TQ300 6383TQ300 6384TQ300 6381TQ400 6381TQ500 6381TQ630 25 25 25 25 25 35 35 35 35 35 50 50 50 50 70 70 70 70 95 95 95 95 120 120 120 120 150 150 150 185 185 185 240 240 240 300 300 300 400 500 630 196/0.40 196/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 276/0.40 276/0.40 276/0.40 396/0.40 396/0.40 396/0.40 396/0.40 360/0.50 360/0.50 360/0.50 360/0.50 475/0.50 475/0.50 475/0.50 475/0.50 608/0.50 608/0.50 608/0.50 608/0.50 756/0.50 756/0.50 756/0.50 925/0.50 925/0.50 925/0.50 1221/0.50 1221/0.50 1221/0.50 1525/0.50 1525/0.50 1525/0.50 2013/0.50 1769/0.60 2257/0.60 1 2 3 4 5 1 2 3 4 5 1 3 4 5 1 3 4 5 1 3 4 5 1 3 4 5 1 3 4 1 3 4 1 3 4 1 3 4 1 1 1 400 1290 1600 2140 2470 520 1308 2080 2610 3187 730 2890 3650 4450 980 3850 4880 5938 1270 4970 6390 7924 1570 6350 7750 7542 1960 7700 9780 2380 9350 11900 3100 12000 15330 3790 14910 19030 4880 6070 7460 Mean Overall Diameter (mm) Lower Limit Upper Limit 12.7 24.3 26.1 28.9 32.0 14.3 26.4 29.3 32.5 34.0 16.5 34.1 37.7 39.03 18.6 38.4 42.7 48.5 20.8 43.3 48.4 54.0 22.8 47.4 53.0 57.9 25.2 52.0 58.0 27.6 57.0 64.0 30.6 65.0 72.0 33.5 72.0 80.0 37.4 41.3 45.5 15.8 30.7 33.0 36.6 40.4 17.9 31.5 37.1 41.1 43.0 20.6 42.9 47.5 49.18 23.3 48.3 54.0 55.0 26.0 54.0 61.0 64.5 28.6 60.0 66.0 58.5 31.4 66.0 73.0 34.4 72.0 80.0 38.3 82.0 91.0 41.9 90.0 101.0 46.8 52.0 56.5 Temperature limits: -25 to +90°C. *Bending radius: Fixed - 5 x overall diameter. Flexing - 7 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 70 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber FleXiBle Mains and contRol caBles Ho7Rn-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonised code type HO7RN-F. Flame propagation to EN 60332-1-2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) 3182P1 3183P1 3184P1 3182P1/5 3183P1/5 3184P1/5 3185P1/5 3187P1/5 3180/12P1/5 3180/19P1/5 3180/27P1/5 3180/37P1/5 3182P2/5 3183P2/5 3184P2/5 3185P2/5 3187P2/5 3180/12P2/5 3181P4 3182P4 3183P4 3184P4 3185P4 3187P4 6381P6 6382P6 6383P6 6384P6 6385P6 6387P6 6381P10 6382P10 6383P10 6384P10 6385P10 6381P16 6382P16 6383P16 6384P16 6385P16 6381P25 6382P25 6383P25 6384P25 6385P25 6381P35 6383P35 6384P35 6385P35 6381P50 6383P50 6384P50 6385P50 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4.0 4.0 4.0 4.0 4 6 6.0 6.0 6.0 6.0 6.0 10 10 10 10 10 16 16 16 16 16 25 25 25 25 25 35 35 35 35 50 50 50 50 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 56/0.30 56/0.30 56/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 84/0.30 80/0.40 80/0.40 80/0.40 80/0.40 80/0.40 126/0.40 126/0.40 126/0.40 126/0.40 126/0.40 196/0.40 196/0.40 196/0.40 196/0.40 196/0.40 276/0.40 276/0.40 276/0.40 276/0.40 396/0.40 396/0.40 396/0.40 396/0.40 2 3 4 2 3 4 5 7 12 19 27 37 2 3 4 5 7 12 1 2 3 4 5 7 1 2 3 4 5 7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 3 4 5 1 3 4 5 95 115 140 132 165 200 240 385 520 700 920 1260 193 235 290 345 520 810 94 275 320 395 485 773 130 350 495 610 760 904 230 640 880 1060 1300 320 850 1090 1345 1680 450 1210 1394 1995 2470 605 1850 2645 2930 825 2890 3635 4450 Mean Overall Diameter (mm) Lower Limit Upper Limit 6.1 6.5 7.1 7.6 8.0 9.0 11.2 14.6 17.6 25.3 29 9.0 9.6 10.7 13.3 17.2 20.6 7.2 11.8 12.7 14.0 15.6 19.8 7.9 13.1 14.1 15.7 17.5 21.6 9.5 17.7 19.1 20.9 22.9 10.8 20.2 21.8 23.8 26.4 12.7 24.3 26.1 28.9 32.0 14.3 29.3 32.5 34.0 16.5 34.1 37.7 39.03 8.0 8.5 9.3 9.8 10.4 11.6 14.4 18.2 22.4 21 26 30 34.2 11.6 12.4 13.8 17.0 21.0 26.2 9 15.1 16.2 17.9 19.9 24.4 9.8 16.8 18.0 20.0 22.9 26.9 11.9 22.6 24.2 26.5 29.1 13.4 25.7 27.6 30.1 33.3 15.8 30.7 33.0 36.6 40.4 17.9 37.1 41.1 43.0 20.6 42.9 47.5 49.18 Temperature limits: -25 to +60°C. Can be supplied suitable for up to 90°C upon special request. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 71 Flexible Cables, PvC And Rubber FleXiBle Mains and contRol caBles Ho7Rn-F Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP) outer sheath 450/750 volts grade. Black. Harmonised code type HO7RN-F. Flame propagation to EN 60332-1-2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) 6381P70 6383P70 6384P70 6385P70 6381P95 6383P95 6384P95 6385P95 6381P120 6383P120 6384P120 6381P150 6383P150 6384P150 6381P185 6383P185 6384P185 6381P240 6383P240 6384P240 6381P300 6381P400 6381P500 6381P630 70 70 70 70 95 95 95 95 120 120 120 150 150 150 185 185 185 240 240 240 300 400 500 630 360/0.50 360/0.50 360/0.50 360/0.50 475/0.50 475/0.50 475/0.50 475/0.50 608/0.50 608/0.50 608/0.50 756/0.50 756/0.50 756/0.50 925/0.50 925/0.50 925/0.50 1221/0.50 1221/0.50 1221/0.50 1525/0.50 2257/0.50 1769/0.60 2257/0.60 1 3 4 5 1 3 4 5 1 3 4 1 3 4 1 3 4 1 3 4 1 1 1 1 1090 3850 4830 5938 1405 4185 6320 6695 1745 5051 6453 1824 6267 8031 2202 7661 9830 2847 9692 12444 3495 4880 5301 7460 Mean Overall Diameter (mm) Lower Limit Upper Limit 18.6 38.4 42.7 48.5 20.8 43.3 48.5 54.0 22.8 47.4 53.0 25.2 52.0 58.0 27.6 57.0 64.0 30.6 65.0 72.0 33.5 45.5 41.3 45.5 23.3 48.3 54.0 55.0 26.0 50 61.0 64.5 28.6 60.0 66.0 31.4 66.0 73.0 34.4 72.0 80.0 38.3 82.0 91.0 41.9 56.5 52.0 56.5 Temperature limits: -25 to +60°C. Can be supplied suitable for up to 90°C upon special request. *Bending radius: Static - 6 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 72 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber touGH RuBBeR sHeatH FleXiBle coRds Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, tough rubber sheath. Black. 300/500 volts grade to BS6500 and BS7919. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 3182/75 3183/75 3184/75 31821 31831 31841 31821/5 31831/5 31841/5 31851/5 31822/5 31832/5 31842/5 31852/5 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 30/0.20 30/0.20 30/0.20 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 50/0.25 2 3 4 2 3 4 2 3 4 5 2 3 4 5 63 78 94 77 90 110 115 135 170 195 165 195 245 290 6.6 7.2 7.8 7.1 7.5 8.2 8.7 9.2 9.8 10.3 10.3 11.0 11.9 12.3 20/16 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20S 20S 20S 20 20 Temperature limits: +60°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core - Grey, Black, Brown, Blue, Green/Yellow. Should not be installed at temperatures below 0°C. BRaided touGH RuBBeR sHeatH FleXiBle coRds Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, chlorosulphonated polyethylene bedding (CSP), tinned copper wire braid screen, chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500/75 and 450/750 Volts grade to BS6007/75 (where applicable). Black. Flame propagation to BS 4066 PT1 and IEC 332 PT1. Heat and oil resistant and flame retardant (HOFR). CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 3802TQ1 3803TQ1 3804TQ1 3802TQ1/5 3803TQ1/5 3804TQ1/5 3802TQ2/5 3803TQ2/5 3804TQ2/5 3803TQ4 3804TQ4 6803TQ6 6804TQ6 6803TQ10 6804TQ10 6803TQ16 6804TQ16 1.0 1.0 1.0 1.5 1.5 1.5 2.5 2.5 2.5 4.0 4.0 6.0 6.0 10.0 10.0 16.0 16.0 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 56/0.30 56/0.30 84/0.30 84/0.30 90/0.40 90/0.40 126/0.40 126/0.40 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 3 4 170 200 230 225 270 320 300 350 420 715 865 973 1166 1592 1878 1992 2452 11.1 11.4 12.1 12.3 13.1 14.2 14.8 15.6 17.0 21.3 23.6 24.8 27.1 30.7 33.3 33.8 37.2 20/16 20/16 20/16 20/16 20S 20S 20S 20 20 25 25 25 32 32 40 40 40 Temperature limits: -25 to +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Blue, Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 73 Flexible Cables, PvC And Rubber coil end lead FleXiBle Mains caBles Flexible tinned annealed copper conductors composite ethylene propylene rubber chlorosulphonated polyethylene (EPR-CSP) insulation to BS6195/69 Type 4. A. 300/500 volts grade C. 600/1000 volts grade D. 1900/3300 volts grade E. 3800/6600 volts grade F. 6350/11000 volts grade Conductor CCC Code Size (mm2) Stranding (mm) TYPE 4 1/5 TYPE 4 2/5 TYPE 4 4 TYPE 4 6 TYPE 4 10 TYPE 4 16 TYPE 4 25 TYPE 4 35 TYPE 4 50 TYPE 4 70 TYPE 4 95 TYPE 4 120 TYPE 4 150 TYPE 4 185 TYPE 4 240 TYPE 4 300 TYPE 4 400 TYPE 4 500 0.5 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 16/0.20 24/0.20 32/0.20 30/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 608/0.50 756/0.50 925/0.50 1221/0.50 1525/0.50 2013/0.50 3679/0.40 CCC Code Approx. Max Dia. Of Dia. Of Wires Cond. (mm) (mm) 0.21 0.21 0.21 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.51 0.61 0.93 1.14 1.32 1.60 2.00 2.6 3.6 4.6 5.7 7.1 8.5 10.3 12.4 14.5 16.0 18.0 20.0 23.0 26.0 30.0 29.0 Radial Thickness Of Insulation Voltage Category A C D E F (mm) (mm) (mm) (mm) (mm) 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.2 - 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.5 1.6 1.6 1.7 1.8 2.0 2.2 2.3 2.4 2.4 2.6 2.8 3.0 2.8 2.8 2.8 2.8 2.8 2.8 3.0 3.0 3.0 3.0 3.0 3.0 3.0 - 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 - 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 - Temperature limits: -20 to +90°C. *Bending radius: 6 x overall diameter. Should not be installed at temperatures below -25°C. Minimum Overall Diameter Weight Voltage Category Voltage Category A C D E F A C D E F (mm) (mm) (mm) (mm) (mm) (Kg/Km) (Kg/Km)(Kg/Km)(Kg/Km) (Kg/Km) 3.3 3.5 3.7 TYPE 4 1/5 4.0 TYPE 4 2/5 4.6 TYPE 4 4 5.4 TYPE 4 6 6.5 TYPE 4 10 7.9 TYPE 4 16 TYPE 4 25 TYPE 4 35 TYPE 4 50 TYPE 4 70 TYPE 4 95 TYPE 4 120 TYPE 4 150 TYPE 4 185 TYPE 4 240 TYPE 4 300 TYPE 4 400 TYPE 4 500 - 4.5 4.7 4.9 5.2 5.6 6.3 7.5 8.5 9.6 11.4 12.8 14.8 17.2 19.7 21.9 24.1 26.3 29.3 33.0 37.4 34.8 8.5 12.4 13.8 15.2 17.1 19.2 22.0 23.5 25.5 27.5 30.5 33.8 37.8 - 17.2 18.6 20.0 21.1 24.2 26.3 27.8 29.8 32.1 35.1 - 22.9 24.1 25.5 27.3 29.4 31.5 33.3 35.3 37.3 40.3 - 12 16 19 25 37 57 80 130 - 17 21 24 30 41 66 93 136 206 300 406 573 793 1028 1285 1562 1914 2431 3024 3948 4920 76 255 351 458 616 820 1097 1340 1635 1973 2504 3098 4045 - 384 495 613 796 1020 1287 1542 1853 2225 2782 - 566 680 810 997 1237 1520 1804 2131 2503 3081 - Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 74 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Flexible Cables, PvC And Rubber WeldinG caBles 0361tQ Tinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated, chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1). CCC Code Conductor Size (mm2) Stranding (mm) Weight (Kg/Km) Outside Diameter (mm) Gland Size (mm) 0361TQ16OR 0361TQ25OR 0361TQ35OR 0361TQ50OR 0361TQ70OR 0361TQ95OR 0361TQ120OR 0361TQ185OR 16 25 35 50 70 95 120 185 513/0.20 783/0.20 1107/0.20 1566/0.20 2214/0.20 2997/0.20 608/0.50 925/0.50 235 330 440 610 840 1120 1410 2100 11.5 13.0 14.5 17.0 19.5 22.0 24.0 29.0 20S 20 25 25 32 32 32 40 Temperature limits: -20 to +85°C. *Bending radius: 8 x overall diameter. RuBBeR FlatFoRM caBles Flexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath (TPR). Black. 600/1000 volts grade. CCC Current Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Dimensions (mm) Max Ratings (Amps) FLAT4X1/5R FLAT12X1/5R FLAT4X2/5R FLAT7X2/5R FLAT12X2/5R FLAT4X4R FLAT4X6R FLAT4X10R FLAT4X16R FLAT4X25R FLAT4X35R FLAT4X50R FLAT4X70R 1.5 1.5 2.5 2.5 2.5 4 6 10 16 25 35 50 70 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 4 12 4 7 12 4 4 4 4 4 4 4 4 110 320 170 300 490 250 330 550 800 1350 1800 2400 3250 16X5 29X5 19X6 33X7 51X6 21X7 24X7 29X9 35X10 46X14 51X15 56X17 63X18 22 12 30 20 20 40 52 70 95 127 157 190 242 Temperature limits: -35 to +85°C. *Bending radius: 10 x overall diameter. Core identification: 4 core - Black, Grey, Brown, Green/Yellow. 7 and 12 core - Black cores with White numbers and one Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 75 Flexible Cables, PvC And Rubber PVc FlatFoRM caBles Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black. 450/750 volts grade type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6. CCC Current Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Dimensions (mm) Max Ratings (Amps) FLAT4X1/5v FLAT12X1/5v FLAT4X2/5v FLAT12X2/5v FLAT4X4v FLAT4X6v FLAT4X10v FLAT4X16v FLAT4X25v FLAT4X35v FLAT4X50v FLAT4X70v FLAT4X95v 1.5 1.5 2.5 2.5 4 6 10 16 25 35 50 70 95 30/0.25 30/0.25 50/0.25 50/0.25 56/0.30 84/0.30 80/0.40 126/0.40 196/0.40 276/0.40 396/0.40 360/0.50 475/0.50 4 12 4 12 4 4 4 4 4 4 4 4 4 150 420 210 620 300 385 620 990 1550 2030 2650 3650 4550 15X5 41X5 19X6 51X6 21X7 23X7 29X9 37X11 46X14 51X15 56X17 63X18 73X21 20 11 27 16 36 48 63 85 112 138 168 213 258 Temperature limits: -25 to +70°C. *Bending radius: 10 x overall diameter. Core identification: 4 core - Black, Grey, Brown, Green/Yellow. 12 core - Black cores with white numbers and one Green/Yellow. Should not be installed at temperatures below 0°C. silicon FleXiBle caBles siHF Flexible tinned annealed copper conductors, silicone insulated, silicone outer sheath. 300/500 volts grade to VDE 0250 PT816. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) BIHF2X/75 BIHF3X/75 BIHF4X/75 BIHF2X1 BIHF3X1 BIHF4X1 BIHF2X1/5 BIHF3X1/5 BIHF4X1/5 BIHF5X1/5 BIHF2X2/5 BIHF3X2/5 BIHF4X2/5 0.75 0.75 0.75 1.0 1.0 1.0 1.5 1.5 1.5 1.5 2.5 2.5 2.5 24/0.20 24/0.20 24/0.20 32/0.20 32/0.20 32/0.20 30/0.25 30/0.25 30/0.25 30/0.25 50/0.25 50/0.25 50/0.25 2 3 4 2 3 4 2 3 4 5 2 3 4 53.4 63.7 83.6 59.9 78.3 94.6 82.0 98.0 122.0 148.0 135.0 152.0 188.0 6.5 6.9 7.9 6.7 7.5 8.1 7.6 8.0 8.8 9.6 8.9 9.1 10.1 20/16 20/16 20/16 20/16 20/16 20S 20/16 20/16 20S 20S 20S 20S 20S Temperature limits: -60 to +180°C. *Bending radius: Fixed - 5 x overall diameter. Flexing - 15 x overall diameter. Core identification: 2 core - Blue, Brown. 3 core - Blue, Brown, Green/Yellow. 4 core - Grey, Black, Brown, Green/Yellow. 5 core and above - Grey, Black, Brown, Blue, Green/Yellow. 6 core and above - Black with White numbers plus Green/Yellow. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 76 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables SECTION 8 Instrumentation, Control & Communication Cables Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation, Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. PAS5308 PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. Pt1 CCC Code Pt2 7100 7101 7102 7103 7104 7105 7106 7107 7136 7137 7138 7139 7140 7141 7142 7143 7173 7174 7175 7176 7177 N/A N/A 7178 72700 72701 72702 72703 72704 72705 72707 7300 7301 7302 7303 7304 7305 7306 7307 7336 7337 7338 7339 7340 7341 7342 7343 7373 7374 7375 7376 7377 N/A N/A 7378 - Conductor Size (mm2) Stranding (mm) No. Of Pairs 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 16/0.2 16/0.2 16/0.2 16/0.2 16/0.2 16/0.2 16/0.2 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 30 1 TRIPLE Weight Outside (Kg/Km) Diameter (mm) 60 75 190 305 518 759 1251 69 69 99 242 380 684 989 1670 83 87 145 345 575 1075 1720 2750 115 60 75 190 305 518 759 69 6.00 6.90 12.10 16.20 21.30 25.90 32.90 6.10 6.30 7.30 13.30 17.70 23.50 28.50 36.40 6.80 7.30 8.70 15.40 20.60 27.50 33.7 43.6 8.40 6.00 6.90 12.10 16.20 21.30 25.90 6.10 Brass A2 Gland 20/16 20/16 20 25 32 32 50S 20/16 20/16 20/16 20 25 32 40 50S 20/16 20/16 20S 25 32 40 50S 63S 20S 20/16 20/16 20 25 32 32 20/16 Temperature limits: -20 to +65°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 78 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. PAS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1. Pt1 CCC Code Pt2 7112 7113 7114 7115 7116 7117 7149 7150 7151 7152 7153 7154 7185 7186 7187 7188 - 7312 7313 7314 7315 7316 7317 *7349 7350 7351 7352 7353 7354 7385 7386 7387 7388 - Conductor Size (mm2) Stranding (mm) No. Of Pairs 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 2 5 10 20 30 50 2 5 10 20 30 50 2 5 10 20 30 50 Weight Outside (Kg/Km) Diameter (mm) 161 253 408 753 1153 1900 184 299 489 920 1445 2460 242 408 714 1337 2040 3260 11.00 14.20 20.10 26.30 31.30 40.70 11.80 15.30 21.70 28.80 34.50 44.00 13.70 17.80 25.50 33.40 40.4 52.2 Brass A2 Gland 20S 25 32 40 40 50 20 25 32 40 50S 63S 25 25 32 50S 50 63 Temperature limits: -20 to +65°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 79 Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, Polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. CCC Code Pt1 Pt2 7118 7119 7120 7121 7122 7123 7124 7125 7155 7156 7157 7158 7159 7160 7161 7162 7231 7232 7233 7234 7235 7236 7237 7189 7190 7191 7192 7193 7194 7195 7196 7208 7209 7210 7211 7212 7213 7318 7319 7320 7321 7322 7323 7324 7325 7355 7356 7357 7358 7359 7360 7361 7362 7389 7390 7391 7392 7393 7394 7395 7396 7408 7409 7410 7411 7412 7413 Conductor Stranding No. Of Weight Overall Gland Size (mm) Pairs (Kg/Km) Diameter Size (mm2) (mm) (mm) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 16/0.20 1 16/0.20 2 16/0.20 5 16/0.20 10 16/0.20 20 16/0.20 30 16/0.20 50 16/0.201 TRIPLE 24/0.20 1 24/0.20 2 24/0.20 5 24/0.20 10 24/0.20 20 24/0.20 30 24/0.20 50 24/0.201 TRIPLE 1/1.13 1 1/1.13 2 1/1.13 5 1/1.13 10 1/1.13 20 1/1.13 30 1/1.13 50 7/0.53 1 7/0.53 2 7/0.53 5 7/0.53 10 7/0.53 20 7/0.53 30 7/0.53 50 7/0.53 1 TRIPLE 7/0.67 1 7/0.67 2 7/0.67 5 7/0.67 10 7/0.67 20 7/0.67 1 TRIPLE 242 288 535 868 1466 1944 3360 259 270 330 719 1150 1704 2570 4400 288 250 300 560 970 1240 2180 3500 312 397 918 1466 2519 3352 5310 357 395 490 1430 2235 3935 407 10.8 11.7 17.3 22.3 28.5 33.3 41.5 11.0 11.1 12.3 19.2 24.7 30.7 36.9 46.4 11.4 11.8 13.0 19.7 24.3 31.2 36.2 45.7 12.3 13.7 21.5 27.8 35.1 41.9 53.4 12.6 13.1 15.9 26.5 35.1 46.7 13.7 20/16 20S 20 25 32 32 50S 20/16 20/16 20S 20 25 32 40 50S 20S 20/16 20s 20 25 40 50s 50 20S 20S 25 32 40 50S 63S 20S 20S 20 20 40 50 20S Nylon Cleat Size 0.5 0.5 0.7 0.9 1.2 1.4 1.8 0.5 0.5 0.5 0.8 1.0 1.2 1.6 2.0 0.5 0.5 0.6 0.8 1.0 1.4 1.6 2.0 0.5 0.6 0.9 1.1 1.4 1.8 TC9 0.5 0.6 0.6 1.1 1.4 2.0 0.6 Temperature limits: -20 to +65°C. *Bending radius: 6 x overall diameter.. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 80 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. Pt1 CCC Code Pt2 Conductor Size (mm2) 7130 7131 7132 7133 7134 7135 7167 7168 7169 7170 7171 7172 7201 7202 7203 7204 7205 7206 7330 7331 7332 7333 7334 7335 7367 7368 7369 7370 7371 7372 7401 7402 7403 7404 7405 7406 0.5 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 Stranding No. Of Weight Overall (mm) Pairs (Kg/Km) Diameter (mm) 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 24/0..20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 2 5 10 20 30 50 2 5 10 20 30 50 2 5 10 20 30 50 460 730 1202 1870 2620 4180 518 805 1323 2323 3312 5520 707 1185 1668 2956 3650 5640 16.8 19.90 26.90 34.3 40.5 51.5 16.60 21.00 28.50 36.80 42.90 54.00 19.40 24.40 32.50 41.60 50.8 62.6 Gland Size (mm) Nylon Cleat Size 20 20 32 40 50S 50 20 25 32 40 50S 63S 20 25 32 50S 50 63 0.7 0.8 1.1 1.4 1.6 TC9 0.7 0.9 1.2 1.6 1.8 TC9 0.8 1.0 1.4 1.8 TC9 TC10 Temperature limits: -20 to +65°C. *Bending radius: 6 x overall diameter. Core identification: Part 1 colour code chart on page 96. Part 2 colour code chart on page 97. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 81 Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) sheath, Blue or Black, to PAS5308 Part 1, Type 1 LSZH. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs Weight (Kg/Km) Overall Diameter (mm) Brass A2 Gland 7246 7247 7248 7249 7250 7251 7243 7273 7274 7275 7276 7277 7278 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 1 2 5 10 20 30 1 TRIPLE 1 2 5 10 20 1 TRIPLE 69 99 242 380 684 989 83 87 145 345 575 1075 115 6.30 7.30 13.30 17.70 23.50 28.50 6.8 7.3 8.7 15.4 20.60 27.50 8.40 20/16 20/16 20 25 32 40 20/16 20/16 20S 25 32 40 20S Temperature limits: -20 to +65°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar tape screened. Complete with 0.5mm2 drain wire, collective aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) outer sheath, Black or Blue, generally to PAS5308 Part 1, Type 1 LSZH. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs Weight (Kg/Km) Overall Diameter (mm) Brass A2 Gland 72712 72713 72714 72715 72716 71149 71150 71151 71152 7253 0.5 0.5 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 16/0.2 16/0.2 16/0.2 16/0.2 16/0.2 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 2 5 10 20 30 2 5 10 20 30 161 253 408 753 1153 184 299 489 920 1445 11.00 14.20 20.10 26.30 31.30 11.80 15.30 21.70 28.80 34.50 20S 25 32 40 40 20 25 32 40 50S Temperature limits: -20 to +65°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 82 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to PAS5308 Part 1, Type 2 LSZH. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 72718 72719 7255 7256 7257 7258 7259 7260 7261 72362 7289 7290 7291 7292 7293 7496 7308 7309 7310 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 16/0.2 16/0.2 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.2 24/0.2 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 1 2 1 2 5 10 20 30 50 1 TRIPLE 1 2 5 10 20 1 TRIPLE 1 2 5 Weight Overall (Kg/Km) Diameter (mm) 242 288 270 330 719 1150 1704 2570 4400 288 312 397 918 1466 2519 357 395 490 1430 10.80 11.70 10.70 11.90 18.80 24.30 30.30 36.9 46.4 11.4 11.90 13.30 21.10 27.40 35.50 12.6 13.1 15.9 26.5 Gland Size (mm) Nylon Cleat Size 20/16 20S 20/16 20S 20 25 32 40 50S 20S 20S 20S 25 32 40 20S 20S 20 20 0.5 0.5 0.5 0.5 0.8 1.0 1.2 1.6 2.0 0.5 0.5 0.6 0.9 1.1 1.4 0.5 0.6 0.6 1.1 Temperature limits: -20 to +65°C. *Bending radius: 6 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to PAS5308 Part 1, Type 2 LSZH. CCC Code Conductor Size (mm2) 7230 72131 72132 7267 7268 7269 7270 72563 72566 72569 7298 7299 7297 7296 0.5 0.5 0.5 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 Stranding (mm) No. Of Pairs 16/0.2 2 16/0.2 5 16/0.2 10 24/0.20 2 24/0.20 5 24/0.20 10 24/0.20 20 24/0.2 2 TRIPLE 24/0.2 5 TRIPLE 24/0.2 10 TRIPLE 7/0.53 2 7/0.53 5 7/0.53 10 7/0.53 20 Weight Overall (Kg/Km) Diameter (mm) 460 730 1202 518 805 1323 2323 476 670 1456 707 1185 1668 2956 16.80 19.90 26.90 16.60 21.00 28.50 36.80 15.9 17.8 29 19.40 24.40 32.50 41.60 Gland Size (mm) Nylon Cleat Size 20 20 32 20 25 32 40 20 20 32 20 25 32 50S 0.7 0.8 1.1 0.7 0.9 1.2 1.6 0.7 0.8 1.2 0.8 1.0 1.4 1.8 Temperature limits: -20 to +65°C. *Bending radius: 6 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 83 Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective aluminium/mylar tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. PAS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C. CCC Code Pt1 Pt2 7821 7822 7823 7824 7825 7826 7827 7971 7972 7973 7974 7975 7976 7977 7851 7852 7853 7854 7855 7856 7857 7921 7922 7923 7924 7925 7926 7927 7951 7952 7953 7954 7955 7956 7957 Conductor Stranding No. Of Weight Overall Gland Size (mm) Pairs (Kg/Km) Diameter Size (mm2) (mm) (mm) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 1 2 5 10 20 30 50 1 2 5 10 20 30 50 1 2 5 10 20 30 50 700 795 1598 2280 3630 4385 6895 710 828 1627 2275 3149 4420 6964 940 1051 1973 2823 4498 6207 8961 15.7 16.8 25.1 29.4 37.3 43.1 53.1 15.8 17.0 25.0 29.6 37.6 42.6 53.5 16.9 19.0 27.4 33.2 42.1 50.1 61.0 20 20 25 32 40 50S 63S 20 20 25 32 40 50S 63S 20 20 32 32 50S 50 63 Nylon Cleat Size 0.7 0.7 1.0 1.2 1.6 1.8 TC9 0.7 0.7 1.0 1.2 1.6 1.8 TC9 0.7 0.8 1.1 1.4 1.8 2.0 TC10 Temperature limits: -20 to +65°C. *Bending radius: 5 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 84 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables instRuMentation and contRol caBles - Pas5308 PAS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, polyethylene bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. PAS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. CCC Code Pt1 Pt2 7830 7831 7832 7833 7834 7835 N/A N/A N/A N/A N/A N/A 7870 7871 7872 7873 7874 7875 7930 7931 7932 7933 7934 7935 N/A N/A N/A N/A N/A N/A 7970 7971 7972 7973 7974 7975 Conductor Stranding No. Of Weight Overall Gland Size (mm) Pairs (Kg/Km)Diameter Size (mm2) (mm) (mm) 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 2 5 10 20 30 50 2 5 10 20 30 50 2 5 10 20 30 50 1280 1810 2720 4270 6000 8330 1280 1820 2750 4350 6110 8350 1680 2300 4000 6300 8110 11160 21.5 26.0 32.7 40.9 46.3 58.5 22.3 27.2 34.2 43.8 51.4 62.5 25.5 30.0 40.1 50.2 57.6 70.6 25 25 32 50S 50S 63S 25 25 40 50S 50 63 25 32 50S 50 63S 75S Nylon Cleat Size 0.9 1.1 1.4 1.8 2.0 TC10 0.9 1.1 1.4 1.8 TC9 TC10 1.1 1.2 1.6 2.0 TC10 TC12 Temperature limits: -20 to +65°C. *Bending radius: 15 x overall diameter. Core identification: Part 1 colour code chart on page 86. Part 2 colour code chart on page 87. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 85 Instrumentation, Control & Communication Cables INSTRUMENTATION AND CONTROL CABLES PAS5308 PART 1 COLOUR CODING Pair Number A Wire B Wire Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 BLACK BLACK BLUE BLACK BLUE GREEN BLACK BLUE GREEN BROWN BLACK BLUE GREEN BROWN WHITE BLACK BLUE GREEN BROWN WHITE RED BLACK BLUE GREEN BROWN BLUE GREEN GREEN BROWN BROWN BROWN WHITE WHITE WHITE WHITE RED RED RED RED RED ORANGE ORANGE ORANGE ORANGE ORANGE ORANGE YELLOW YELLOW YELLOW YELLOW 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 WHITE RED ORANGE BLACK BLUE GREEN BROWN WHITE RED ORANGE YELLOW BLACK BLUE GREEN BROWN WHITE RED ORANGE YELLOW GREY BLACK BLUE GREEN BROWN WHITE YELLOW YELLOW YELLOW GREY GREY GREY GREY GREY GREY GREY GREY vIOLET vIOLET vIOLET vIOLET vIOLET vIOLET vIOLET vIOLET vIOLET TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE For individual screened pairs, identification will be Black/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue , Black, Green. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 86 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables INSTRUMENTATION AND CONTROL CABLES PAS5308 PART 2 COLOUR CODING Pair Number A Wire B Wire Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLACK BLACK BLACK BLACK BLACK YELLOW YELLOW YELLOW YELLOW YELLOW WHITE/BLUE WHITE/BLUE WHITE/BLUE WHITE/BLUE WHITE/BLUE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 RED/BLUE RED/BLUE RED/BLUE RED/BLUE RED/BLUE BLUE/BLACK BLUE/BLACK BLUE/BLACK BLUE/BLACK BLUE/BLACK YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE YELLOW/BLUE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE WHITE/ORANGE ORANGE/RED ORANGE/RED ORANGE/RED ORANGE/RED ORANGE/RED BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY For individual screened pairs, identification will be White/Blue numbered pairs. Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue, Green, Brown. Single triple will be Blue, White, Orange. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 87 Instrumentation, Control & Communication Cables instRuMentation and contRol caBles Bsc (coRus) standaRd Plain annealed flexible copper conductors, PVC bedding, tinned annealed copper wire braid screen, PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN 50265 and IEC 60332-1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores BSC1342C BSC1343C BSC1344C BSC1347C BSC13412C BSC13419C BSC13427C BSC13437C 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 2 3 4 7 12 19 27 37 No. Of Cores 2 3 4 7 12 Weight Outside (Kg/Km) Diameter (mm) 420 452 490 579 906 1091 1562 1872 13.4 13.8 14.4 15.9 19.5 21.5 25.5 28.1 Gland Size (mm) Nylon Cleat Size 20S 20S 20S 20S 20 20 25 32 0.6 0.6 0.6 0.7 0.8 0.9 1.1 1.2 Temperature limits: -20 to +70°C. *Bending radius: 6 x overall diameter. Should not be installed at temperatures below 0°C. Colour BROWN BROWN BROWN RED RED vIOLET 19 RED vIOLET RED/BLUE 27 RED vIOLET RED/YLW BLUE/ORANGE 37 RED vIOLET RED/YLW BLUE/ORANGE GRN/GREY vIOLET/WHT BLUE BLUE GREY BLUE BLUE ORANGE BLUE ORANGE RED/GRN BLUE ORANGE RED/WHT BLUE/GRN BLUE ORANGE RED/WHITE BLUE/GRN BROWN/YLW RED/GREY GREEN/YLW GREEN/YLW GREEN GREEN PINK GREEN PINK RED/YLW GREEN PINK RED/BLACK BLUE/GREY GREEN PINK RED/BLACK BLUE/GREY BRN/WHT BLACK YELLOW YELLOW TURQUOISE YELLOW TURQUOISE RED/WHT YELLOW TURQUOISE RED/BROWN GRN/YLW YELLOW TURQUOISE RED/BROWN GREEN/YLW BRN/BLACK WHITE WHITE GREY WHITE GREY RED/BLACK WHITE GREY BLUE/YLW GRN/WHT WHITE GREY BLUE/YLW GRN/WHT BROWN/GREY BLACK BLACK BROWN BROWN BLACK BROWN RED/BROWN BLACK RED/BLUE BLUE/WHE GRN/BLACK BLACK RED/BLUE BLUE/WHT GRN/BLACK vIOLET/YLW BLUE/YLW BROWN RED/GRN BLUE/BLACK BROWN RED/GRN BLUE/BLACK GRN/ORANGE vIOLET/BLACK Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 88 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables instRuMentation and contRol caBles Bsc (coRus) standaRd Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to BS EN 50265 and IEC 60332-1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs BSC1431P BSC1432P BSC1435P BSC14310P BSC14320P BSC14330P BSC14350P 0.75 0.75 0.75 0.75 0.75 0.75 0.75 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 1 2 5 10 20 30 50 Weight Outside (Kg/Km) Diameter (mm) 260 320 672 1112 1665 2525 4137 10.70 11.90 18.80 24.30 30.30 36.5 46 Gland Size (mm) Nylon Cleat Size 20/16 20S 20 25 32 40 50 0.5 0.5 0.8 1.0 1.2 1.6 2.0 Temperature limits: -20 to +70°C. *Bending radius: 6 x overall diameter. Should not be installed at temperatures below 0°C. CORE IDENTIFICATION ACCORDING TO ENATS 09-6 SECTION 3 Pair Number 1 A Wire BLACK B Wire BLUE Pair Number 26 A Wire WHITE B Wire YELLOW 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 BLACK BLACK BLACK BLACK BLUE BLUE BLUE BLUE BLUE ORANGE ORANGE ORANGE ORANGE GREEN GREEN GREEN BROWN BROWN GREY BLACK BLACK BLACK BLACK WHITE ORANGE GREEN BROWN GREY WHITE ORANGE GREEN BROWN GREY WHITE GREEN BROWN GREY WHITE BROWN GREY WHITE GREY WHITE WHITE RED YELLOW vIOLET RED 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 WHITE BLUE BLUE BLUE GREEN GREEN GREEN RED RED RED RED RED GREY GREY ORANGE ORANGE YELLOW YELLOW BROWN TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE vIOLET RED YELLOW vIOLET RED YELLOW vIOLET GREY ORANGE YELLOW BROWN vIOLET YELLOW vIOLET YELLOW vIOLET BROWN vIOLET vIOLET BLACK BLUE RED ORANGE YELLOW Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 89 Instrumentation, Control & Communication Cables inteRnal telePHone caBles tYPe cW1308 Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC sheathed. To BPO CW(M) 1308. Sheath colour: White. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Stranding (mm) No. Of Pairs Weight (Kgs/Km) Overall Diameter (mm) Gland Size (mm) 13000 13001 13002 13004 13005 13006 13013 13007 13008 13009 13010 13012 13014 13016 13018 13020 13022 13023 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 2 3 4 6 10 10+E 12 15 20+E 25+E 30+E 40+E 50+E 60+E 80+E 100+E 160+E 320+E 18 24 35 47 70 102 80 95 126 163 200 273 365 412 501 687 1135 2306 3.6 4.5 5.8 6.8 8.3 8.6 9.1 9.8 10.7 11.4 12.2 15 17.5 20 22.5 24 30.5 39.5 20/16 20/16 20/16 20/16 20/16 20S 20S 20S 20 20 20 25 25 32 32 32 40 50 Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 WHITE/BLUE WHITE/ORANGE WHITE/GREEN WHITE/BROWN WHITE/GREY RED/BLUE RED/ORANGE RED/GREEN RED/BROWN RED/GREY BLACK/BLUE BLACK/ORANGE BLACK/GREEN BLACK/BROWN BLACK/GREY YELLOW/BLUE YELLOW/ORANGE YELLOW/GREEN YELLOW/BROWN YELLOW/GREY vIOLET/BLUE vIOLET/ORANGE vIOLET/GREEN vIOLET/BROWN vIOLET/GREY PINK/BLUE PINK/ORANGE PINK/GREEN PINK/BROWN PINK/GREY BLUE/WHITE ORANGE/WHITE GREEN/WHITE BROWN/WHITE GREY/WHITE BLUE/RED ORANGE/RED GREEN/RED BROWN/RED GREY/RED BLUE/BLACK ORANGE/BLACK GREEN/BLACK BROWN/BLACK GREY/BLACK BLUE/YELLOW ORANGE/YELLOW GREEN/YELLOW BROWN/YELLOW GREY/YELLOW BLUE/vIOLET ORANGE/vIOLET GREEN/vIOLET BROWN/vIOLET GREY/vIOLET BLUE/PINK ORANGE/PINK GREEN/PINK BROWN/PINK GREY/PINK E. denotes earth core. Temperature limits: -20 to +70°C. *Bending radius: 5 x overall diameter. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 90 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables coMMunication caBles - telePHone enats 09-6 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13050 13051 13052 13053 13054 13055 13056 0.28 0.28 0.28 0.28 0.28 0.28 0.28 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 1/0.6 **2 5 10 20 30 50 100 Weight Overall (Kg/Km) Diameter (mm) 170 238 454 496 697 1243 1825 9 12.07 15.91 17.18 18.1 26.60 29.8 Gland Size (mm) Nylon Cleat Size 20/16 20S 20 20 20 32 32 0.5 0.6 0.7 0.7 0.8 1.1 1.2 Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13081 13083 13084 13085 13086 13087 13088 13089 13090 13091 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 **2 5 10 15 20 25 30 40 50 60 75 100 Weight Overall (Kg/Km) Diameter (mm) 206 333 586 796 939 1245 1400 1686 1952 2183 2342 3613 10.31 14.1 17.38 19.5 22.48 21.3 23.9 28.2 32.87 35 37 41.8 Gland Size (mm) Nylon Cleat Size 20S 20S 20 20 25 25 25 32 32 40 40 50S 0.5 0.6 0.7 0.8 0.9 0.9 1.0 1.2 1.4 1.4 1.6 1.8 ** 2 pair laid up in quad formation. Temperature limits: -20 to +70°C. *Bending radius: 6 x overall diameter. Core identification: See colour chart on page 94. Should not be installed at temperatures below 0°C. Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13101 13103 13104 13105 13106 13107 13108 13109 13110 - 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 **2 5 10 15 20 25 30 40 50 100 Weight Overall (Kg/Km) Diameter (mm) 213 379 650 805 955 1256 1413 1700 2110 3628 10.4 14 17.8 20 21.7 24.3 25.9 28.6 31.5 42 Gland Size (mm) Nylon Cleat Size 20/16 20S 20 20 25 25 25 32 32 50S 0.5 0.6 0.8 0.8 0.9 1.0 1.1 1.2 1.4 1.8 ** 2 pair laid up in quad formation. Temperature limits: -20 to +70°C. *Bending radius: 6 x overall diameter. Core identification: See colour chart on page 94. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 91 Instrumentation, Control & Communication Cables coMMunication caBles - telePHone enats 09-6 Solid plain annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13381 13383 13384 13385 13386 13387 13388 13389 13390 13391 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 **2 5 10 15 20 25 30 40 50 100 Weight Overall (Kg/Km) Diameter (mm) 208 353 606 630 854 1159 1266 1549 1923 3000 10.17 13.92 17.49 18.9 21.06 23.2 26.47 28.82 33.5 43.4 Gland Size (mm) Nylon Cleat Size 20S 20S 20 20 25 25 32 32 32 50S 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.8 Solid plain annealed copper conductors, PVC insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13401 13403 13404 13405 13406 13407 13408 13409 13410 13411 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 **2 5 10 15 20 25 30 40 50 100 Weight Overall (Kg/Km) Diameter (mm) 223 349 599 795 900 1159 1332 1435 1926 3041 10.3 13.74 18.14 19.4 22.34 23.5 25.21 28 31.44 44.7 Gland Size (mm) Nylon Cleat Size 20S 20S 20 20 25 25 25 32 32 50S 0.5 0.6 0.8 0.8 0.9 1.0 1.0 1.2 1.4 1.8 **2 pair laid up in quad formation. Temperature limits: -20 to +70°C. *Bending radius: 8 x overall diameter. Core identification: See colour chart on page 94. Should not be installed at temperatures below 0°C or above 40°C. Solid tinned annealed copper, polyethylene insulated, low smoke and zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13501 13503 13504 13506 13510 13511 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 **2 5 10 20 50 100 Weight Overall (Kg/Km) Diameter (mm) 200 326 598 783 1823 3041 9.5 13.7 17.47 20.7 20.74 41 Gland Size (mm) Nylon Cleat Size 20/16 20S 20 25 25 50S 0.6 0.7 0.9 0.9 1.8 Solid plain annealed copper conductors, polyethylene insulated, twisted to form pairs, collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13601 13603 13604 13606 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 **2 5 10 20 Weight Overall (Kg/Km) Diameter (mm) 260 328 602 790 10.9 14.33 17.22 20.8 Gland Size (mm) Nylon Cleat Size 20S 20S 20 25 0.5 0.6 0.7 0.9 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 92 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables utilitY industRY PVc contRol caBles, enats 09-6 Stranded plain annealed copper conductor, PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS6346 / ENATS 09-6. Flame retardant to IEC 60332-3-24c. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores 6942X2/5ESI 6943X2/5ESI 6944X2/5ESI 6947X2/5/7 6940/12X2/5/7 6940/19X2/5/7 6940/27X2/5/7 6940/37X2/5/7 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 2 3 4 7 12 19 27 37 Weight Overall Gland Size (Kg/Km) Diameter (mm) (mm) 329 396 423 672 967 1482 1920 2185 12.2 13.5 14.4 17.2 21.3 25.4 29.3 33.1 20S 20S 20 20 25 25 32 40 Nylon Cleat Size 0.5 0.6 0.6 0.7 0.9 1.1 1.2 1.4 Temperature limits: -30 to +70°C *Bending radius: 6 x Overall Diameter Core identification: White numbered cores. Should not be installed at temperatures below 0°C or above 40°C. coMMunication caBles - telePHone enats 09-6 Solid plain annealed copper conductor, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6 issue 6 section 3 table 2 - induced voltage between the pairs up to 15kv. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size 13187 13188 - 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 7 19 37 900 1800 3000 22.5 32.1 41.7 25 32 50S 0.9 1.4 1.8 Temperature limits: -20 to +70°C. *Bending radius: 8 x Overall Diameter Core identification: 7 pair: centre - red & yellow. outer layer - black & violet, orange & grey**, green & brown, orange & blue**, green & brown, orange & white**. 19 pair: centre - centre and first layer as 7 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. 37 pair: centre, first and second layer as 19 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white. **denotes carrier pairs. Should not be installed at temperatures below 0°C or above 40°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 93 Instrumentation, Control & Communication Cables coRe identiFication accoRdinG to enats 3.6 and 4.5 SECTION 3.6 COLOUR CODING Pair Number A Wire B Wire Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 BLACK BLACK BLACK BLACK BLACK BLUE BLUE BLUE BLUE BLUE ORANGE ORANGE ORANGE ORANGE GREEN GREEN GREEN BROWN BROWN GREY BLACK BLACK BLACK BLACK WHITE BLUE ORANGE GREEN BROWN GREY WHITE ORANGE GREEN BROWN GREY WHITE GREEN BROWN GREY WHITE BROWN GREY WHITE GREY WHITE WHITE RED YELLOW vIOLET RED 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 WHITE WHITE BLUE BLUE BLUE GREEN GREEN GREEN RED RED RED RED RED GREY GREY ORANGE ORANGE YELLOW YELLOW BROWN TURQUOISE TURQUOISE TURQUOISE TURQUOISE TURQUOISE YELLOW vIOLET RED YELLOW vIOLET RED YELLOW vIOLET GREY ORANGE YELLOW BROWN vIOLET YELLOW vIOLET YELLOW vIOLET BROWN vIOLET vIOLET BLACK BLUE RED ORANGE YELLOW All two pair cables are in quad formation and colour coded in rotation - Blue, Orange, Green, Brown. SECTION 4.5 COLOUR CODING Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLACK BLACK BLACK BLACK BLACK YELLOW YELLOW YELLOW YELLOW YELLOW BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY Each unit is lapped with coloured tape for identification as follows UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW vIOLET If sub-units are used, binders for corresponding sub-units shall be the same colour. All two pair cables are in quad formation and colour coded in rotation - White, Red, Blue, Orange. For 30 pair cables the formation will be 3 X 10 pair units numbered - 1, 2 and 3. For 40 pair cables the formation will be 2 X 20 pair units numbered - 1 and 2. For 50 pair cables the formation will be 5 X 10 pair units numbered - 1, 2 3, 4 and 5. For 100 pair cables the formation will be 5 X 20 pair units numbered - 1, 2, 3, 4 and 5. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 94 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables coMMunication caBles PetRoleuM JellY Filled Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, PE outer sheath. Black. To CW1128A. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) Nylon Cleat Size 13030 13031 13032 13034 13035 1/0.50 1/0.50 1/0.50 1/0.50 1/0.50 5 10 20 50 100 48 82 182 317 613 6.83 7.41 11.48 15.5 21.78 20/16 20/16 20 25 32 0.5 0.7 0.9 Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled solid polyethylene bedding, galvanised steel wire armour, PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric construction). Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13040 13041 13042 13043 13044 0.196 0.196 0.196 0.196 0.196 1/0.5 1/0.5 1/0.5 1/0.5 1/0.5 5 10 20 50 100 Weight Overall (Kg/Km) Diameter (mm) 199 276 461 920 1416 10.63 12.4 16.23 21.66 26.58 Gland Size (mm) Nylon Cleat Size 20S 20S 20 25 32 0.5 0.5 0.7 0.9 1.1 Temperature limits: 0 to +40°C maximum continuous temperature of standard jelly compound. Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, collective aluminium/mylar tape screen, polyethylene bedding, galvanised steel wire armour, PVC outer sheath. Black. To BS3573 and CW1128/1198. Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13150 13151 13153 13154 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 5 10 20 50 Weight Overall (Kg/Km) Diameter (mm) 392 620 1078 2155 16.7 19.9 24.8 34.5 Gland Size (mm) Nylon Cleat Size 20 20 25 40 0.7 0.8 1.0 1.6 COLOUR SCHEME FOR BS3573 - UNIT CONSTRUCTION Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 UNIT 8 UNIT 9 UNIT 10 BLUE ORANGE GREEN BROWN GREY WHITE RED BLACK YELLOW vIOLET Cables may be manufactured using 5-pair sub-units coloured as 1-5 and 6-10. If sub-units are used binders for corresponding sub-units shall be the same colour. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 95 Instrumentation, Control & Communication Cables deFence standaRd 61-12 contRol caBles Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder tape, tinned annealed copper wire braid screen, PVC outer sheath. Black. 440 volts grade. To Ministry of Defence Standard DEF 61-12 (Part 4 for 7/0.2 conductors, Part 5 for 16/0.2 conductors). Flame propagation to BS4066 PT1 and IEC 332 PT1. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 722C 723C 724C 726C 728C 7212C 7218C 7225C 7236C 7250C 7260C 1622C 1623C 1624C 1626C 1628C 16210C 16212C 16218C 16225C 16236C 16250C 16260C 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 7/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 2 3 4 6 8 12 18 25 36 50 60 2 3 4 6 8 **10 12 18 25 36 50 60 23 27 32 55 69 83 110 150 200 270 310 69 79 92 120 146 190 198 250 320 450 564 670 4.1 4.3 4.6 5.9 6.0 7.2 8.5 9.8 11.2 13.0 13.8 6.9 7.2 7.7 8.7 8.9 11.8 11.0 12.5 14.6 16.7 18.5 20.3 16 16 16 16 16 16 20 20 20 25 25 16 16 16 20 20 20 20 20 25 25 32 32 Tinned annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulation, non-hygroscopic binder tape, tinned annealed copper wire braid screen, low smoke and zero halogen (LSZH) outer sheath. Black. 440 volt grade. Generally to ministry of Defence Standard DEF61-12 Part 5 LSF. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) LSF1622C LSF1623C LSF1624C LSF1626C LSF16212C LSF16218C LSF16225C 0.50 0.5 0.5 0.5 0.5 0.5 0.5 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 16/0.20 2 3 4 6 12 18 25 69 79 92 120 198 250 320 6.9 7.2 7.7 8.7 11.0 12.5 14.6 16 16 16 20 20 20 25 ** Laid up in a pair configuration. Temperature limits: -55 to +70°C. *Bending radius: 6 x overall diameter. Core identification: See colour chart on page 97. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 96 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables DEFENCE STANDARD 61-12 CONTROL CABLES COLOUR CODING Core Number Colour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35 36 RED BLUE GREEN YELLOW WHITE BLACK BROWN vIOLET ORANGE PINK TURQUOISE GREY RED/BLUE GREEN/RED YELLOW/RED WHITE/RED RED/BLACK YELLOW/BLUE YELLOW/BLUE WHITE/BLUE BLUE/BLACK ORANGE/BLUE GREEN/BLUE GREY/BLUE YELLOW/GREEN WHITE/GREEN GREEN/BLACK ORANGE/GREEN GREY/GREEN YELLOW/BROWN WHITE/BROWN BROWN/BLACK GREY/BROWN YELLOW/vIOLET vIOLET/BLACK vIOLET/BLACK WHITE/vIOLET Where 2 colours are shown the core is striped e.g. Red/Blue - the core is striped Red with Blue. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 97 Instrumentation, Control & Communication Cables coMPensatinG and tHeRMocouPle caBles NON-ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1. No Of Pairs Conductor Size (mm2) Stranding (mm) Overall Diameter (mm) Gland Size (mm) Jx CCC Code Kx CCC Code Tx CCC Code 7500 Kcb CCC Code (Was Vx) 7530 1 0.75 24/0.20 6.7 20/16 7570 7550 2 5 10 20 0.75 0.75 0.75 0.75 24/0.20 24/0.20 24/0.20 24/0.20 7.7 13.7 18.1 23.9 20/16 25 25 32 7501 7503 7505 7507 7531 7533 7537 7539 7571 7573 7575 7577 7551 7553 7557 7559 Temperature limits: -30 to +105°C. *Bending radius: 5 x overall diameter. Core identification: See colour chart on page 99. Should not be installed at temperatures below 0°C. ARMOURED Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer sheath. Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1. No Of Pairs Conductor Size (mm2) Stranding (mm) Overall Diameter (mm) Gland Size (mm) Jx CCC Code Kcb CCC Code (Was Vx) Kx CCC Code Tx CCC Code 1 2 5 10 20 0.75 0.75 0.75 0.75 0.75 24/0.20 24/0.20 24/0.20 24/0.20 24/0.20 11.1 12.3 19.2 24.7 30.7 20/16 20/16 20 25 32 7600 7601 7603 7605 7607 7640 7641 7643 7645 7647 7700 7701 7703 7705 7707 7660 7661 7663 7665 7667 Temperature limits: -30 to +105°C. *Bending radius: 6 x overall diameter. Core identification: See colour chart on page 99. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 98 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables coMPensatinG and tHeRMocouPle caBles COLOUR CODING EX JX KX +- +- +- NX TX UX VX +- +- +- +- CODE BRITISH BS1843: 1952 +- +- +- +- +- +- +- AMERICAN ANSI +- +- +- +- +- GERMAN DIN +- +- +- +- RC/SC KCB +- +- IEC 584-3 +- +- +- +- +- +- IEC 584-3 INTRINSICALLY SAFE Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 99 Instrumentation, Control & Communication Cables tRaFFic siGnallinG caBles TRAFFIC CONTROL CABLE WITH ARMOUR Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised steel wire armour, PVC outer sheath, colour orange, generally to BS6346/87 CCC Code Conductor Size (mm2) TRAF4X1 TRAF8X1 TRAF12X1 TRAF16X1 TRAF20X1 TRAF4X1/5 TRAF8X1/5 TRAF12X1/5 TRAF16X1/5 TRAF20X1/5 TRAF8X1ESWA* 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.0 Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 1/1.13 1/1.13 1/1.13 1/1.13 1/1.13 1/1.38 1/1.38 1/1.38 1/1.38 1/1.38 1/1.13 4 8 12 16 20 4 8 12 16 20 8 325 413 567 774 905 363 534 704 836 1040 533 13.3 15.6 17.9 19.9 22.0 12.5 15.8 18.5 20.0 21.5 16.3 20S 20S 20 20 25 20S 20 20 20 25 20 Temperature limits: -15 to +70°C. *Bending radius: 6 x overall diameter. Core identification: 4 core - Red, Blue, Yellow, Green. 8 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange. * includes additional 6mm2 integral earth conductor. 12 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue violet. 16 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red. 20 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, violet/Red, Orange/Red, Green/Red, Blue/White. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 100 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Instrumentation, Control & Communication Cables tRaFFic siGnallinG caBles TRAFFIC CONTROL CABLE NON ARMOURED Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour orange, generally to BS6346/87, 600/1000v grade. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Brass A2 Gland TRAF8X1NA TRAF12X1NA TRAF8X1E* 1.0 1.0 1.0 1/1.13 1/1.13 1/1.13 8 12 8 218 305 523 12.6 13.5 14.49 20 25 25 Temperature limits: -15 to +70°C. *Bending radius: 6 x overall diameter. Core identification: 4 core - Red, Blue, Yellow, Green. 8 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange. * includes additional 6mm2 integral earth conductor. 12 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue violet. 16 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red. 20 core - Brown, Yellow, Green, Red, White, Blue, Black, Orange, Red/White, Grey, Red/Blue, violet, Brown/Red, Yellow/Red, Grey/Red, Black/Red, violet/Red, Orange/Red, Green/Red, Blue/White. Should not be installed at temperatures below 0°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 101 Instrumentation, Control & Communication Cables tRaFFic siGnallinG caBles LOOP FEEDER CABLE NON ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene outer sheath, colour orange, 600/1000v grade. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) LOOP2X1/5 LOOP4X1/5 LOOP2X2/5 LOOP4X2/5 1.5 1.5 2.5 2.5 1/1.38 1/1.38 1/1.78 1/1.78 2 (1pr) 4 (2pr) 2 (1pr) 4 (2pr) 80 123 110 180 9.0 9.1 9.3 10.7 20S 20S 20S 20S LOOP FEEDER CABLE ARMOURED Plain annealed solid copper conductors, polyethylene insulated, polyethylene bedding, galvanised steel wire armour, polyethylene outer sheath. Generally to BS6346/87. Outer sheath colour: Orange. 600/1000 volts grade. CCC Code Conductor Size (mm2) LOOP2X1/5SWA LOOP4X1/5SWA LOOP2X2/5SWA LOOP4X2/5SWA 1.5 1.5 2.5 2.5 Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) 1/1.38 1/1.38 1/1.78 1/1.78 2 (1pr) 4 (2pr) 2 (1pr) 4 (2pr) 235 300 279 383 11.8 12.7 12.5 15.0 20S 20S 20S 20 Temperature limits: -15 to +70°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. Should not be installed at temperatures below 0°C. Temperature limits: -15 to +70°C. *Bending radius: 6 x overall diameter. Core identification: 2 core - Brown, Blue 4 core - Brown, Black, Grey, Blue. LOOP DETECTOR CABLE Tinned flexible copper conductor, ethylene propylene rubber insulated (EPR), polychloroprene sheathed (PCP), 600/100v generally to BS6500 + BS6195, sheath colour black. Should not be installed at temperatures below 0°C. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size (mm) LOOP1/5 LOOP2/5 1.5 2.5 30/.025 50/0.25 1 1 53.8 64.0 7.0 7.9 20S 20S Temperature limits: -30 to +85°C. *Bending radius: 6 x overall diameter. Should not be installed at temperatures below -25°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 102 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Data Cables SECTION 9 Data Cables Data Cables data, coaXial and lan caBles BELDEN EQUIvALENTS: 8138/SWA/LSF 8 PAIR 28AWG COLLECTIvE SCREEN PLUS STEEL WIRE ARMOUR,LSF SHEATH. 8471 1 PAIR 16AWG UNSCREENED, PvC SHEATH. 8471/LSF 1 PAIR 16AWG UNSCREENED, PvC SHEATH. 8719 1 PAIR 16AWG COLLECTIvE SCREEN, PvC SHEATH. 8719/LSF 1 PAIR 16AWG COLLECTIvE SCREEN, LSF SHEATH. 8723/LSF 2 PAIR 22AWG INDIvIDUAL SCREEN ,LSOH SHEATH. 8723/SWA/LSF 2 PAIR 22AWG INDIvIDUAL SCREEN PLUS STEEL WIRE ARMOUR, LSF SHEATH. 8760 1 PAIR 18AWG COLLECTIvE SCREEN. PvC SHEATH. 8760/LSF 1 PAIR 18AWG COLLECTIvE SCREEN. LSOH SHEATH. 8761 1 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH. 8761/LSF 1 PAIR 22AWG INDIvIDUAL SCREEN, LSOH SHEATH. 8762 1 PAIR 20AWG COLLECTIvE SCREEN, PvC SHEATH. 8762/LSF 1 PAIR 20AWG COLLECTIvE SCREEN, LSOH SHEATH. 8777 3 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH. 8778 6 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH. 9182 1 PAIR 22AWG COLLECTIvE SCREEN, PvC SHEATH. 9463 TWIN AXIAL 20AWG, PvC SHEATH. 9463/SWA/PvC TWIN AXIAL 20AWG PLUS STEEL WIRE ARMOUR, PvC SHEATH. 9501 1 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH. 9501/LSF 1 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9502 2 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH. 9502/LSF 2 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9503 3 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH. 9503LSF 3 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9504 4 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH. 9504LSF 4 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9505LSF 5 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9506 6 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH. 9506LSF 6 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9729 2 PAIR 24AWG INDIvIDUAL SCREEN, PvC SHEATH. 9773 3 PAIR 18AWG INDIvIDUAL SCREEN, PvC SHEATH. 9841LSF 1 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. 9842LSF 2 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH. COAXIAL CABLES CT100 CT100LSOH CCF100BK CC100BK CCF125BR CT125 CT125LSOH CT125BR CT125RBS CT167 CT167RBS RG11AU RG11SWA RG58 RG59BU RG59LSOH RG59SWA RG62AU RG62SWA URM202 URM203 URM70 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH. 75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, DIRECT BURIAL SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PvC SHEATH. 50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PvC SHEATH. 93 OHM BRAIDED SCREEN, PE TUBE AND THREAD, PvC SHEATH. 93 OHM BRAIDED SCREEN, PE TUBE AND THREAD PLUS SWA, PvC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PvC SHEATH. 75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PvC SHEATH. 75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH. UTP CABLES 4UTPCAT5E 4UTPCAT5EBU 4UTPCAT5ELSF 4FTPCAT5E 4FTPCAT5ELSF 4UTPCAT5EDUCT 4FTPCAT5EDUCT 4FTPCAT5ESWA 4UTPCAT6 4UTPCAT6LSF ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PvC SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, BLUE PvC SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSF vIOLET SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PvC SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, LSF vIOLET SHEATH. ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH. ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH. UNSCREENED 4 PAIR CAT 6, GREY PvC SHEATH. UNSCREENED 4 PAIR CAT 6, LSF vIOLET SHEATH. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 104 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Railway Cables SECTION 10 Railway Cables Railway Cables RailWaY siGnallinG caBles Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3 for types B1, LSZH insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath for types A1 & B1, LSZH sheath for types A2 & A3. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC Code A11X/75BR A11X/75RD A11X/75OR A11X/75GY A11X/75vIR A11X/75BK A11X115BK A21X/75 A21X115 A32X/75 A34X/75 A36X/75 A310X/75 A314X/75 A336X/75 A348X/75 B11X2/5 B11X10 B11X35 B22X1/5 B22X2/5 B22X10 B22X16 B22X35 B22X70 B22X95 B24X/75 B24X1/5 B24X2/5 B24X10 B27X/75 B27X1/5 B27X2/5 B210X/75 B210X1/5 B210X2/5 B212X/75 B26PX/75 B212X1/5 B212X2/5 B219X/75 B219X1/5 B219X2/5 B227X/75 B227X1/5 B227X2/5 B237X/75 B237X1/5 B237X2/5 B248X/75 B248X1/5 B248X2/5 Rail Code Rail Type Conductor Stranding No. Of Weight Overall Gland Size (mm) Cores (Kg/Km) Diameter Size (mm) (mm2) 6/120002 A1 Brown 6/120003 A1 Red 6/120004 A1 Orange 6/120005 A1 Grey 6/120006 A1 violet 6/120007 A1 Black 6/120008 A1 Black 6/120020 A2 6/120024 A2 6/120040 A3 6/120041 A3 6/120042 A3 6/120043 A3 6/120044 A3 6/120045 A3 6/120046 A3 6/120061 B1 6/120062 B1 6/120063 B1 6/120081 B2 6/120082 B2 6/120083 B2 6/120113 B2 6/120084 B2 6/120085 B2 6/120086 B2 6/120087 B2 6/120088 B2 6/120089 B2 B2 6/120090 B2 6/120091 B2 6/120092 B2 6/120093 B2 6/120094 B2 6/120095 B2 6/120096 B2 6/120111 B2 6/120097 B2 6/120098 B2 6/120099 B2 6/120100 B2 6/120101 B2 6/120102 B2 6/120103 B2 6/120104 B2 6/120105 B2 6/120106 B2 6/120107 B2 6/120108 B2 6/120109 B2 6/120110 B2 0.75 0.75 0.75 0.75 0.75 0.75 1.15 0.75 1.15 0.75 0.75 0.75 0.75 0.75 0.75 0.75 2.5 10 35 1.5 2.5 10 16 35 70 95 0.75 1.5 2.5 10 0.75 1.5 2.5 0.75 1.5 2.5 0.75 0.75 1.5 2.5 0.75 1.5 2.5 0.75 1.5 2.5 0.75 1.5 2.5 0.75 1.5 2.5 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 16/0.30 7/0.37 16/0.30 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.37 7/0.67 7/1.35 19/1.53 7/0.53 7/0.67 7/1.35 7/1.70 19/1.53 19/2.14 19/2.52 7/0.37 7/0.53 7/0.67 7/1.35 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 7/0.37 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 1 1 1 1 1 1 1 1 1 2 4 6 10 14 36 48 1 1 1 2 2 2 2 2 2 2 4 4 4 4 7 7 7 10 10 10 12 6pr 12 12 19 19 19 27 27 27 37 37 37 48 48 48 16 16 16 16 16 16 20 30 35 67 108 160 259 495 752 963 34 205 495 135 170 443 625 1232 2043 2945 150 220 295 675 225 370 500 280 401 680 321 469 410 730 425 615 815 606 897 1200 786 1126 1600 972 1280 1960 2.95 N/A 2.95 N/A 2.95 N/A 2.95 N/A 2.95 N/A 2.95 N/A 3.25 N/A 4.50 N/A 4.80 20/16 7.75 20/16 9.20 20S 11.10 20S 14.35 25 15.75 25 24.20 32 27.50 40 8.05 20/16 10.60 20S 14.50 25 10.75 20S 11.80 20 16.85 25 18.80 25 25.05 32 64.80 75 74.70 90 11.50 20S 12.30 20 13.35 20 19.0 32 13.25 20 14.20 25 15.50 25 16.20 25 17.50 25 19.20 25 16.65 25 22.15 32 18.00 25 19.80 25 19.15 25 20.80 32 22.95 32 22.60 32 25.00 32 27.65 40 22.60 32 28.25 40 31.25 40 28.95 40 31.60 40 35.10 50S Temperature limits: -25 to +85°C. *Bending radius: 8 x overall diameter. Core identification: Black with white numbers. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 106 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Railway Cables RailWaY siGnallinG caBles Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655-3.2. Heavy duty PCP RS2 sheath for types C1 + C2, LSZH sheath for types D1, D2, E1+E2. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005). CCC Code Rail Code C11X2/5 6/120130 C22X2/5 6/120140 C24X2/5 6/120141 C27X2/5 6/120142 C210X2/5 6/120143 C212X2/5 6/120144 C216X2/5 6/120145 D11X/75 6/120211 D11X1/5 6/120212 D11X2/5 6/120213 D11X10 6/120214 D11X35 6/120215 D22X1/5 6/120216 D22X2/5 6/120217 D22X10 6/120218 D22X16 6/1220226 D22X35 6/120219 D24X1/5 6/120223 D27X1/5 6/120228 D210X1/5 6/120231 D212X1/5 6/120234 D219X1/5 6/120237 D227X/75 6/120238 D227X1/5 6/120239 D227X2/5 6/120240 D237X/75 6/120241 D237X1/5 6/120242 D237X2/5 6/120243 D248X/75 6/120244 D248X1/5 6/120245 D248X2/5 6/120246 E11X2/5 6/120172 E22X2/5 6/120170 E24X2/5 6/120171 E27X2/5 6/120173 E210X2/5 6/120174 E212X2/5 6/120175 Rail Type C1 C2 C2 C2 C2 C2 C2 D1 D1 D1 D1 D1 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 D2 E1 E2 E2 E2 E2 E2 Conductor Stranding Size (mm) (mm2) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 0.75 1.5 2.5 10 35 1.5 2.5 10 16 35 1.5 1.5 1.5 1.5 1.5 0.75 1.5 2.5 0.75 1.5 2.5 0.75 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 7/0.37 7/0.53 7/0.67 7/1.35 19/1.53 7/0.53 7/0.67 7/1.35 7/1.70 19/1.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 7/0.37 7/0.53 7/0.67 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 50/0.25 No. Of Weight Cores (Kg/Km) 1 2 4 7 10 12 16 1 1 1 1 1 2 2 2 2 2 4 7 10 12 19 27 27 27 37 37 37 48 48 48 1 2 4 7 10 12 174 342 445 590 784 868 980 25 30 34 205 495 135 170 443 625.0 1232 200.0 370.0 401.0 410.0 615.0 606 897 1200 786 1126 1600 972 1280 1960 174 342 445 590 784 868 Overall Gland Diameter Size (mm) 12.60 25 16.85 25 18.65 25 42.40 50 25.55 40 26.25 40 28.65 40 7.30 20/16 7.65 20/16 8.05 20/16 10.60 20S 14.50 25 10.75 20S 11.80 20 16.85 25 20.9 32 25.05 40 13.2 25 15.8 25 19.4 32 17.3 32 23.1 32 22.60 32 25.00 32 27.65 40 25.55 32 28.25 40 31.25 40 28.95 40 31.60 40 35.10 50S 12.60 20 16.85 25 18.65 25 21.20 32 25.55 32 26.25 40 Temperature limits: -25 to +85°C. *Bending radius: 8 x overall diameter. Core identification: Black with white numbers. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 107 Railway Cables RailWaY tRain PRotection WaRninG caBles Flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3, separate drain wire,single aluminium tape screen (polyester backed). Black Heavy duty PCP RS2 sheath to BS7655 for type C3, LSZH sheath for type E3. Manufactured to Network Rail specification NR/PS/SIG/OOOO5 (formerly RT/E/PS/00005). CCC Code Rail Code Rail Type Conductor Stranding Size (mm) (mm2) C3TPWS E3TPWS 6/160086 6/160090 C3TPWS E3TPWS 2.5 2.5 50/0.25 50/0.25 No. Of Weight Overall Gland Cores (Kg/Km) Diameter Size (mm) 1PR 1PR 250 250 17.50 17.50 25 25 Temperature limits: -25 to +85°C. *Bending radius: 8 x overall diameter. RailWaY Point HeateR caBles Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black PCP type EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly R/E/PS/40045). CCC Code Rail Code Conductor Size (mm2) Stranding (mm) No. Of Cores 3184PH1/5 3188PH1/5 3188PH2/5 6388PH4 6388PH6 6388PH10 6388PH16 6/150002 6/153002 6/153103 - 1.5 1.5 2.5 4.0 6.0 10.0 16.0 30/0.25 30/0.25 50/0.25 56/0.30 84/0.30 75/0.40 118/0.40 4 8 8 8 8 8 8 Weight Overall (Kg/Km) Diameter (mm) 220 460 510 830 1040 1799 2480 14.32 18.44 23.36 23.60 25.60 31.70 36.20 Gland Size 25 25 32 32 32 40 50S Temperature limits: -30 to +70°C. Core identification: 4 core - Yellow, Yellow, Blue, Blue. 8 core - Yellow, Yellow, Blue, Blue, Brown, Brown, Black, Black. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 108 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Railway Cables RailWaY aXle countinG caBles Solid plain annealed copper conductors, polyethylene insulation, petroleum jelly filled, polyethylene outer sheath. Manufactured to Network Rail specification RT/E/PS/0031. CCC Code Rail Code Conductor Size (mm2) Stranding (mm) No. Of Pairs F1D0902 F1D0910 F1D0912 F1D0919 F1D0924 F1D1402 F1D1410 F1D1412 F1D1419 F1D1424 6/170001 6/170002 6/170003 6/170004 6/170005 6/170121 6/170122 6/170123 6/170124 6/170125 0.63 0.63 0.63 0.63 0.63 1.5 1.5 1.5 1.5 1.5 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/1.4 1/1.4 1/1.4 1/1.4 1/1.4 2 10 12 19 24 2 10 12 19 24 Weight Overall (Kg/Km) Diameter (mm) 165 526 633 1034 1326 318 1020 1691 1691 2419 13.20 21.60 24.80 31.20 33.80 23.40 30.00 32.00 37.30 42.30 Gland Size 25 32 32 40 50S 32 40 50S 50S 50S Two pair cables laid up in quad formation colour coded in rotation, Orange, White, Green, Black. Temperature limits: -40 to +70°C. *Bending radius: 15 x overall diameter. Core identification: Pair No A Wire B Wire Pair No A Wire B Wire 1 2 3 4 5 6 7 8 9 10 11 12 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED YELLOW YELLOW BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE 13 14 15 16 17 18 19 20 21 22 23 24 YELLOW YELLOW YELLOW vIOLET vIOLET vIOLET vIOLET vIOLET TURQUOISE TURQUOISE TURQUOISE TURQUOISE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN RailWaY datalinK caBle Solid copper conductor, polyethylene insulation, aluminium/polyethylene laminated moisture barrier, polyethylene sheath black or blue. To BR1932. CCC Code Rail Code DATALINK2X1/27 DATALINK2X1/27BU DATALINK2X1/27LSF 6/166065 6/166065 6/166065 Stranding No. Of (mm) Cores 1/1.27 1/1.27 1/1.27 2 2 2 Weight (Kg/Km) Overall Diameter (mm) Gland Size 136 136 136 12.47 12.47 12.47 25 25 25 Temperature limits: PE sheath -40 to + 70°C. LSZH sheath -10 to + 50°C. *Bending radius: 15 x overall diameter. Core identification: Blue, Red. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 109 Railway Cables RailWaY aXle countinG caBle non aRMouRed Solid tinned annealed copper conductors, polyethylene insulation (type 03 to BS6234), petroleum jelly filled (XPS and XQS types only), glass fibre weave, aluminium/polymer laminate tape, polyethylene sheath XPS type (type 03C to BS6234) or LSZH XPZ type. Manufactured to Network Rail specification RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG30060. CCC Code Rail Code XPS0902 XPS0910 XPS0912 XPS0919 XPS0924 XPS1402 XPS1410 XPS1412 XPS1419 XPS1424 XPZ0902 XPZ0910 XPZ0912 XPZ0919 XPZ0924 XPZ1402 XPZ1410 XPZ1412 XPZ1419 XPZ1419 006/170007 006/170008 006/170009 006/170034 006/170035 006/170036 006/170037 006/170038 006/170039 006/170040 006/170023 006/170024 006/170025 006/170026 006/170027 006/170028 006/170029 006/170030 006/170031 006/170032 Pair 1 2 3 4 5 6 7 8 9 10 11 12 Cable Type Conductor Standing Size (mm) (mm2) XPS XPS XPS XPS XPS XPS XPS XPS XPS XPS XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ XPZ 0.63 0.63 0.63 0.63 0.63 1.5 1.5 1.5 1.5 1.5 0.63 0.63 0.63 0.63 0.63 1.5 1.5 1.5 1.5 1.5 Core Colours White White White White White Red Red Red Red Red Yellow Yellow Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/1.4 1/1.4 1/1.4 1/1.4 1/1.4 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 1/1.4 1/1.4 1/1.4 1/1.4 1/1.4 Pair 13 14 15 16 17 18 19 20 21 22 23 24 No. Of Pairs Weight Overall (Kg/Km) Diameter (mm) 2 10 12 19 24 2 10 12 19 24 2 10 12 19 24 2 10 12 19 24 215 530 584 810 982 320 910 1016 1460 1787 200 424 468 632 746 314 807 909 1284 1548 13.8 24.7 26.4 31.4 34.5 16.4 31.4 33.8 40.8 45.0 13.8 24.7 26.4 31.4 34.5 16.4 31.4 33.8 40.8 45.0 Temperature limits: - 25 to + 85°C. *Bending radius: 7.5 x overall diameter Core identification: Table 6 core colours: Core Colours Yellow Yellow Yellow violet violet violet violet violet Turquoise Turquoise Turquoise Turquoise Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Table 7 layer make-up: Pair Nos. In Each Layer NO. OF PAIRSCENTRE 2 1 & 2 10 1 & 2 12 1 -> 3 19 1 24 1 & 2 1ST LAYER 3 -> 10 4 -> 12 2 -> 7 3 -> 10 Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 110 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Railway Cables FiXed telePHone netWoRK (Ftn) coPPeR tRacKside caBles Solid plain annealed copper conductors to BS6360, polyethylene insulation, petroleum jelly filled, corrugated steel armour, polyethylene outer sheath. Manufactured to Network Rail specification NR/PS/TEL/00015 (formerly RT/E/PS/00015). CCC Code Rail Code Conductor Size (mm2) Stranding (mm) No. Of Pairs 13781 13784 13786 13788 13790 6/168061 6/168063 6/168064 6/168065 6/168066 0.63 0.63 0.63 0.63 0.63 1/0.9 1/0.9 1/0.9 1/0.9 1/0.9 2 10 20 30 50 Pair Number A Wire B Wire 1 2 3 4 5 6 7 8 9 10 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY Weight Overall (Kg/Km) Diameter (mm) 250 520 820 915 1550 19.00 23.80 27.60 30.9 35.70 Gland Size 20 25 32 32 32 Temperature limits: -25 to +85°C. Core identification: 2 PAIR (laid up in quad formation). Bending radius: 10 x overall diameter. 20 PAIR (laid up in 4x5 pair) PAIR NUMBER Sub-Unit (Code A) A WIRE B WIRE Pair Number Sub-Unit (Code B) A Wire B Wire 1 2 3 4 5 WHITE WHITE WHITE WHITE WHITE BLUE ORANGE GREEN BROWN GREY 1 2 3 4 5 RED RED RED RED RED BLUE ORANGE GREEN BROWN GREY Each unit is lapped with coloured tape for identification as follows: Unit Number Unit Code Colour Of Bindings 1 2 3 4 A B C D BLUE BLUE ORANGE ORANGE 30 PAIR (laid up in 3x10 pair) 50 PAIR (laid up in 5x10 pair) Each unit is lapped with coloured tape for identification as follows: Pair Number Sub-Unit (Code A) A Wire B Wire 1 2 3 4 5 6 7 8 9 10 WHITE WHITE WHITE WHITE WHITE RED RED RED RED RED BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEN BROWN GREY UNIT NUMBER 1 2 3 4 5 COLOUR OF BINDINGS BLUE ORANGE GREEN BROWN GREY Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 111 Railway Cables RailWaY PoWeR and tRacK FeedeR caBles POWER CABLES Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath, Black to BR880 06/142639. 600/1000 volts grade to BS 5467. CCC Code Rail Code SAC2X16NA 6/142419 SAC2X25NA 6/142519 SAC2X35NA 6/142609 SAC2X50NA 6/142629 SAC2X70NA 6/142639 SAC2X95NA 6/142644 SAC4X70NA 6/151469 Conductor Size (mm2) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) Gland Size 16 25 35 50 70 95 70 2 2 2 2 2 2 4 420 455 525 620 840 1020 1750 14.30 16.60 18.00 20.40 22.80 26.20 30.60 25 25 25 32 32 40 40 Temperature limits: +90°C. *Bending radius: 8 x overall diameter. Core identification: 2 core - Brown, Blue. 4 core - Blue, Brown, Black, Grey. TRACK FEEDER CABLES Uncompacted circular stranded aluminium to BS6360 or uncompacted. Circular stranded tinned copper to BS6360. CSP sheathed type RS4 to BS6899, black. Manufactured to Network Rail specification NR/PS/ELP/21101 (formerly RT/E/S/21101). CCC Code Rail Code TRACK150 TRACK161 TRACK240 TRACK500 TRACK500CU TRACK630CU TRACK800 TRACK1000 TRACK240LSF TRACK800LSF TRACK1000LSF 6/116601 6/132340 6/132990 6/132840 6/132992 6/116612 6/132991 6/116610 - Polarity Conductor Stranding No. Of Size (mm) Cores (mm2) NEGATIvE NEGATIvE NEGATIvE POSITIvE NEGATIvE POSITIvE NEGATIvE POSITIvE NEGATIvE NEGATIvE POSITIvE 150 AL 161 CU 240 AL 500 AL 500 CU 630 CU 800 AL 1000 AL 240 AL 800 AL 1000 AL 37/2.25 91/1.53 61/2.25 61/3.20 91/2.65 127/2.52 127/2.85 127/3.20 61/2.25 127/2.85 127/3.2 1 1 1 1 1 1 1 1 1 1 1 Weight Overall Gland (Kg/Km) Diameter Size (mm) 540 1887 1076 2245 5291 6692 3255 3943 1076 3255 3943 19.40 24.80 28.30 40.20 40.60 44.20 48.50 53.00 28.3 48.5 53.0 25 32 40 50 50 63S 63S 63 40 63S 63 Temperature limits: -25°C to +85°C. *Bending radius: Aluminium conductor - 10x overall diameter. Copper conductor - 8x overall diameter. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 112 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables SECTION 11 Marine And Offshore Cables Marine And Offshore Cables UKOOA Cable Identifier G n F 02 1st Character - Fire Performance/voltage Rating 2nd Character - Cable Construction 3rd Character - No. of Cores, Pairs, Trips or Quads 4th & 5th Characters - Conductor Cross Sectional Areas 1st character F G H J K L Fire resistant, reduced halogen Fire resistant, LSF Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, LSF Flame retardant, reduced halogen 150/250v 150/250v 8.7/15kv 150/250v 150/250v 600/1000v M N P W X Y Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, LSF Flame retardant, reduced halogen Flame resistant, low smoke and fume 3.8/6.6kv 1.9/3.3kv 6.35/11kv 600/1000v 600/1000v 600/1000v 2nd character A B C D E F G H J K L M N P Y Basic construction Flame retardant Flame retardant Fire resistant Fire resistant Flame retardant Flame retardant Flame retardant Flame retardant Flame retardant Flame retardant Fire resistant Fire resistant Fire resistant Fire resistant Flame retardant Sheath colour Black (600/1000v), Red (Hv) Black (600/1000v), Red (Hv) Black (600/1000v) Black (600/1000v) Green/Yellow Black Light Blue Light Blue Grey Grey Light Blue Light Blue Grey Grey Orange Armour Bronze braid GSWB Bronze braid GSWB None None GSWB GSWB GSWB GSWB GSWB GSWB GSWB GSWB GSWB Screen See Note 2 See Note 2 See Note 2 See Note 2 None None Collective Individual Collective Individual Collective Individual Collective Individual Co-axial Single Core 2 Core 3 Core 4 Core 7 Core 12 Core B C D F H J 19 Core 27 Core 37 Core 1 Pair 3 Pair 7 Pair K L M N R S 12 Pair 20 Pair 27 Pair 37 Pair 1 Triple 3 Triple T U X Y Z 2 Triple 12 Triple 1 Quad 3 Quad 7 Quad 4th character 00 01 02 03 04 05 06 10 16 25 35 Notes: 1. Shaded entries signify non-preferred core sizes 2. Hv Cables above 1.9/3.3Kv rating have tinned copper tape and semiconducting insulating screen Common Types: 600/1000 v LB** - 658*B EPR/CSP/GSWB/CSP BLUE WB** - 658*D EPR/ZH/GSWB/ZH XD** - FS 658*B MT/EPR/ZH/GSWB/CSP YD** - FS 658*D MT/EPR/ZH/GSWB/ZH 150/250 v 3rd character 1 2 3 4 7 A Example given: GNF02 Would be: G - Fire Resistant LSF N - Fire Resistant, Grey, GSWB, Coll Scr F - 1 Pair 02 - 1.5mm2 0.75 mm2 Flexible (class 5) stranded tinned copper cores 1.0 mm2 Flexible (class 5) stranded tinned copper cores 1.5 mm2 Flexible (class 5) stranded tinned copper cores 2.5 mm2 Stranded tinned copper cores 4 mm2 Stranded tinned copper cores 4 mm2 Stranded tinned copper cores 6 mm2 Stranded tinned copper cores 10 mm2 Stranded tinned copper cores 16 mm2 Stranded tinned copper cores 25 mm2 Stranded tinned copper cores 35 mm2 Stranded tinned copper cores 50 70 95 OA OB OC OD OE OF OG OH 50 mm2 Stranded tinned copper cores 70 mm2 Stranded tinned copper cores 95 mm2 Stranded tinned copper cores 120 mm2 Stranded tinned copper cores 150 mm2 Stranded tinned copper cores 185 mm2 Stranded tinned copper cores 240 mm2 Stranded tinned copper cores 300 mm2 Stranded tinned copper cores 400 mm2 Stranded tinned copper cores 500 mm2 Stranded tinned copper cores 630 mm2 Stranded tinned copper cores JG** JJ** FG** FJ** JH** JK** FM** FP** KG** KJ** GL** GN** KH** KK** GM** GP** - EPR/COL/CSP/GSWB/CSP BLUE - EPR/COL/CSP/GSWB/CSP GREY - MT/EPR/ZH/CSP/GSWB/CSP BLUE - MT/EPR/ZH/CSP/GSWB/CSP GREY - EPR/IND/CSP/GSWB/CSP BLUE - EPR/IND/CSP/GSWB/CSP GREY - MT/EPR/IND/ZH/GSWB/CSP BLUE - MT/EPR/IND/ZH/GSWB/CSP GREY - EPR/COL/ZH/GSWB/ZH BLUE - EPR/COL/ZH/GSWB/ZH GREY - MT/EPR/COL/ZH/GSBW/ZH BLUE - MT/EPR/COL/ZH/GSBW/ZH GREY - EPR/IND/ZH/GSWB/ZH BLUE - EPR/IND/ZH/GSWB/ZH GREY - MT/EPR/IND/ZH/GSWB/ZH BLUE - MT/EPR/IND/ZH/GSWB/ZH GREY Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 114 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) UKOOA Code 6571TQ1/5 6572TQ1/5 6573TQ1/5 6574TQ1/5 6575TQ1/5 6576TQ1/5 6577TQ1/5 6578TQ1/5 6570/10TQ1/5 6570/12TQ1/5 6570/19TQ1/5 6570/27TQ1/5 6570/30TQ1/5 6570/37TQ1/5 6571TQ2/5 6572TQ2/5 6573TQ2/5 6574TQ2/5 6575TQ2/5 6576TQ2/5 6577TQ2/5 6578TQ2/5 6570/10TQ2/5 6570/12TQ2/5 6570/19TQ2/5 6570/27TQ2/5 6570/30TQ2/5 6570/37TQ2/5 6571TQ4 6572TQ4 6573TQ4 6574TQ4 6575TQ4 6577TQ4 6571TQ6 6572TQ6 6573TQ6 6574TQ6 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 4.0 6.0 6.0 6.0 6.0 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 7/1.04 7/1.04 7/1.04 7/1.04 1 2 3 4 5 6 7 8 10 12 19 27 30 37 1 2 3 4 5 6 7 8 10 12 19 27 30 37 1 2 3 4 5 7 1 2 3 4 49 125 150 180 190 240 275 295 360 440 740 970 1015 1220 63 160 190 240 280 470 355 398 519 650 860 1220 1270 1610 90 240 280 360 425 530 115 305 370 475 5.5 8.9 9.4 10.3 11.0 12.2 12.5 13.3 16.2 16.4 19.3 23.5 24.3 26.0 6.0 9.8 10.4 11.4 12.6 16.9 13.7 15.3 17.7 18.3 21.7 26.3 27.1 29.5 6.9 12.0 12.7 13.9 15.3 17.7 7.5 13.1 13.9 15.4 WF102 WF202 WF302 WF402 WF502 WF702 WFA02 WFB02 WFC02 WFD02 WF103 WF203 WF303 WF403 WF503 WF703 WFA03 WFB03 WFC03 WFD03 WF104 WF204 WF304 WF404 WF504 WF704 WF106 WF206 WF306 WF406 Core identification: White with Black numbers. Single cores available in either Black or Green/Yellow outer sheath. Temperature limits: -15 to +90°C. *Bending radius: 4 x overall diameter. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 115 Marine And Offshore Cables MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) UKOOA Code 6571TQ10 6572TQ10 6573TQ10 6574TQ10 6571TQ16 6572TQ16 6573TQ16 6574TQ16 6571TQ25 6572TQ25 6573TQ25 6574TQ25 6571TQ35 6572TQ35 6573TQ35 6574TQ35 6571TQ50 6572TQ50 6573TQ50 6574TQ50 6571TQ70 6573TQ70 6574TQ70 6571TQ95 6573TQ95 6574TQ95 6571TQ120 6573TQ120 6571TQ150 6571TQ185 6571TQ240 6571TQ300 6571TQ400 6571TQ500 6571TQ630 10 10 10 10 16 16 16 16 25 25 25 25 35 35 35 35 50 50 50 50 70 70 70 95 95 95 120 120 150 185 240 300 400 500 630 7/1.35 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 7/1.70 19/1.35 19/1.35 19/1.35 19/1.35 19/1.53 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 37/1.78 37/1.78 37/1.78 37/2.03 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 91/2.36 91/2.65 127/2.52 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 3 4 1 3 4 1 3 1 1 1 1 1 1 1 165 470 595 745 230 655 830 1045 380 1090 1340 1680 490 1310 1630 2130 640 1720 2210 2840 870 3080 3950 1150 4060 5170 1440 5130 1770 2200 2780 3450 4400 5600 6910 9.0 16.0 17.2 18.9 10.1 18.3 19.5 21.7 12.4 22.9 24.4 27.1 13.6 25.3 27.1 30.1 15.5 29.0 30.9 34.6 17.5 35.3 39.2 19.6 40.3 45.1 21.4 44.4 23.8 26.3 29.5 32.6 36.7 40.5 44.4 WF110 WF210 WF310 WF410 WF116 WF216 WF316 WF416 WF125 WF225 WF325 WF425 WF135 WF235 WF335 WF435 WF150 WF250 WF350 WF450 WF170 WF370 WF470 WF195 WF395 WF495 WF10A WF30A WF10B WF10C WF10D WF10E WF10F WF10G WF10H Single core cables are available in Black or Green/Yellow outer sheath. Temperature limits: -15 to +90°C. *Bending radius: up to 25mm - 4 x overall diameter. above 25mm - 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 116 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC Code Conductor Size (mm2) 6582TQ1/5 6583TQ1/5 6584TQ1/5 6585TQ1/5 6586TQ1/5 6587TQ1/5 6580/12TQ1/5 6580/19TQ1/5 6580/27TQ1/5 6580/37TQ1/5 6582TQ2/5 6583TQ2/5 6584TQ2/5 6585TQ2/5 6586TQ2/5 6587TQ2/5 6580/12TQ2/5 6580/19TQ2/5 6580/27TQ2/5 6580/37TQ2/5 6582TQ4 6583TQ4 6584TQ4 6585TQ4 6587TQ4 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 4.0 4.0 4.0 Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) UKOOA Code 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/0.85 7/0.85 7/0.85 2 3 4 5 6 7 12 19 27 37 2 3 4 5 6 7 12 19 27 37 2 3 4 5 7 300 325 395 407 425 525 790 1090 1515 1870 350 400 470 485 550 635 990 1390 1990 2500 480 530 585 700 897 13.3 13.8 15.0 15.2 16.5 17.2 21.7 24.7 29.3 33.2 14.2 15.0 16.1 16.9 18.2 18.5 23.9 27.6 33.2 36.7 16.6 17.3 18.4 20.2 22.7 WB202 WB302 WB402 WB702 WBA02 WBB02 WBC02 WBD02 WB203 WB303 WB403 WB503 WB703 WBA03 WBB03 WBC03 WBD03 WB204 WB304 WB404 WB504 WB704 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 117 Marine And Offshore Cables MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSF) outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) UKOOA Code 6582TQ6 6583TQ6 6584TQ6 6582TQ10 6583TQ10 6584TQ10 6582TQ16 6583TQ16 6584TQ16 6582TQ25 6583TQ25 6584TQ25 6582TQ35 6583TQ35 6584TQ35 6582TQ50 6583TQ50 6584TQ50 6582TQ70 6583TQ70 6584TQ70 6582TQ95 6583TQ95 6584TQ95 6582TQ120 6583TQ120 6584TQ120 6582TQ150 6583TQ150 6584TQ150 6583TQ185 6584TQ185 6583TQ240 6584TQ240 6583TQ300 6584TQ300 6 6 6 10 10 10 16 16 16 25 25 25 35 35 35 50 50 50 70 70 70 95 95 95 120 120 120 150 150 150 185 185 240 240 300 300 7/1.04 7/1.04 7/1.04 7/1.35 7/1.35 7/1.35 7/1.70 7/1.70 7/1.70 19/1.35 19/1.35 19/1.35 19/1.53 19/1.53 19/1.53 19/1.78 19/1.78 19/1.78 19/2.14 19/2.14 19/2.14 37/1.78 37/1.78 37/1.78 37/2.03 37/2.03 37/2.03 37/2.25 37/2.25 37/2.25 37/2.52 37/2.52 61/2.25 61/2.25 61/2.52 61/2.52 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 570 635 760 750 930 1080 1020 1190 1450 1500 1800 2500 1810 2400 2880 2510 3000 3670 2940 3980 4840 3813 5290 6310 4692 6480 7770 5634 7700 9400 9550 11520 12300 14840 14850 17938 17.9 18.7 20.1 21.0 22.4 24.0 23.7 24.9 26.9 29.0 30.7 33.6 31.0 34.0 36.2 36.0 38.1 41.0 36.0 42.8 46.1 40.9 48.5 52.6 44.9 52.9 57.4 48.9 57.9 63.1 63.8 69.6 71.5 78.3 78.8 84.9 WB206 WB306 WB406 WB210 WB310 WB410 WB216 WB316 WB416 WB225 WB325 WB425 WB235 WB335 WB435 WB250 WB350 WB450 WB270 WB370 WB470 WB295 WB395 WB495 WB20A WB30A WB40A WB20B WB30B WB40B WB30C WB40C WB30D WB40D WB30E WB40E Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 118 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low smoke, zero halogen bedding tinned phosphor bronze braid armour, low smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to IEC90092-353, IEC60331-21, IEC60332-2, IEC60332-2-22, IEC60751-2,2 and IEC61034-1,2. CCC Code Conductor Size (mm2) Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter (mm) UKOOA Code 6591TQ6 6591TQ10 6591TQ16 6591TQ25 6591TQ35 6591TQ50 6591TQ70 6591TQ95 6591TQ120 6591TQ150 6591TQ185 6591TQ240 6591TQ300 6591TQ400 6591TQ500 6591TQ630 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 7/1.04 7/1.35 7/1.70 19/1.35 19/1.53 19/1.78 19/2.14 37/1.78 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 91/2.36 91/2.65 127/2.52 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 245 320 395 565 740 940 1270 1600 1930 2330 3000 3710 4480 5340 6540 8000 11.7 13.4 14.5 17.3 18.4 20.3 22.7 25.0 27.2 29.5 33.1 36.6 40.0 43.9 48.1 52.3 WAB06 WAB10 WAB16 WAB25 WAB35 WAB50 WAB70 WAB95 WABOA WABOB WABOC WABOD WABOE WABOF WABOG WABOH Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: White. Should not be installed at temperatures below -15°C. FiRe Resistant, ePR insulated BRaided aRMouRed sHiPWiRinG caBle 1.5MM to0 10MM MaRine and oFFsHoRe caBles Tinned annealed stranded copper conductors, MICA glass taped, ethylene propylene rubber (EPR) insulated low smoke, zero halogen (LSF) bedding, galvanised steel wire braid armour, low smoke, zero halogen (SW4) outer sheath to BS7655-2,6.Black. 600/1000 volts grade to BS7917/6883, IEC60332-1, IEC60332-3-22, IEC61034-1,2, IEC60754-1,2 and IEC60331-21 CCC Code Conductor Size (mm2) 6582TQ1/5MGT 6583TQ1/5MGT 6584TQ1/5MGT 6587TQ1/5MGT 6580/12TQ1/5MGT 6580/19TQ1/5MGT 6580/27TQ1/5 6582TQ2/5MGT 6583TQ2/5MGT 6584TQ2/5MGT 6587TQ2/5MGT 6580/12TQ2/5MGT 6580/19TQ2/5MGT 6580/27TQ2/5 6583TQ4MGT 6584TQ4MGT 6583TQ6MGT 6583TQ10MGT 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4.0 4.0 6.0 10.0 Stranding (mm) No. Of Cores Weight (Kg/Km) Overall Diameter UKOOA Code 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.67 7/0.85 7/0.85 7/1.04 7/1.35 2 3 4 7 12 19 27 2 3 4 7 12 19 27 3 4 3 3 300 325 395 525 790 1090 1515 350 400 470 635 990 1390 1990 530 585 635 930 13.3 13.8 15.0 17.2 21.7 24.7 29.3 14.2 15.0 16.1 18.5 23.9 27.6 33.2 17.3 18.4 18.7 22.4 YD202 YD302 YD402 YD702 YDA02 YDB02 YDC02 YD203 YF303 YD403 YD703 YDA03 YDB03 TDC03 YD304 YD404 YD306 YD310 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: White with Black numbers. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 119 Marine And Offshore Cables ePR insulated oVeRall scReened sHiPWiRinG caBle to Bs6883 and uKooa Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape. Collective screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. CCC Code KJH00 KJJ00 KJK00 KJL00 KGH00 KGJ00 KGK00 KGL00 KJS00 KGS00 KJT00 KGT00 KJU00 KGU00 KJH02 KJJ02 KJK02 KJL02 KGH02 KGJ02 KGK02 KGL02 KJS02 KJT02 Conductor Size (mm2) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 Stranding (mm) No. Of Pairs Weight (Kg/Km) Sheath Colour UKOOA Code 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.50 7/0.50 3 7 12 20 3 7 12 20 3Triple 3Triple 7Triple 7Triple 12Triple 12Triple 3 7 12 20 3 7 12 20 3Triple 7Triple 420 660 1000 1570 420 660 1000 1570 510 510 820 820 1290 1290 520 850 1470 2130 520 850 1470 2130 680 1100 GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY GREY KJH00 KJJ00 KJK00 KJL00 KGH00 KGJ00 KGK00 KGL00 KJS00 KGS00 KJT00 KGT00 KJU00 KGU00 KJH02 KJJ02 KJK02 KJL02 KGH02 KGJ02 KGK02 KGL02 KJS02 KJT02 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: pairs - black , white numbered triples - black, white, red numbered. quad - black, white, red, blue numbered. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 120 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables ePR insulated indiViduallY scReened sHiPWiRinG caBle to Bs6883 and uKooa Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape.Each pair individually screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. CCC Code KKF00 KHF00 KKX00 KHX00 KKH00 KKJ00 KKK00 KKL00 KHH00 KHJ00 KHK00 KHL00 KKF01 KHF01 KKX01 KHX01 KKF02 KKG02 KHF02 KKX02 KHX02 KKH02 KKJ02 KKK02 KKL02 KHH02 KHJ02 KHK02 KHL02 KKF03 Conductor Size (mm2) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.00 1.00 1.00 1.00 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 2.50 Stranding (mm) No. Of Pairs Weight (Kg/Km) Sheath Colour UKOOA Code 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 7/0.4 7/0.4 7/0.4 7/0.4 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 1 1 1Quad 1Quad 3 7 12 20 3 7 12 20 1 1 1Quad 1Quad 1 2 1 1Quad 1Quad 3 7 12 20 3 7 12 20 1 230 230 310 310 430 720 1110 1670 430 720 1110 1670 240 240 340 340 290 370 290 370 370 560 980 1700 2430 560 980 1700 2430 330 GREY BLUE GREY BLUE GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY KKF00 KHF00 KKX00 KHX00 KKH00 KKJ00 KKK00 KKL00 KHH00 KHJ00 KHK00 KHL00 KKF01 KHF01 KKX01 KHX01 KKF02 KKG02 KHF02 KKX02 KHX02 KKH02 KKJ02 KKK02 KKL02 KHH02 KHJ02 KHK02 KHL02 KKF03 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: pairs - black , white numbered triples - black, white, red numbered. quad - black, white, red, blue numbered. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 121 Marine And Offshore Cables FiRe Resistant, ePR insulated oVeRall scReened sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655: section 1.2 Mica glass tape insulation, EPR, GP4 insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape. Collective screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound. (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to BS7917/BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21. CCC Code GNH00 GNJ00 GNK00 GNL00 GLH00 GLJ00 GLK00 GLL00 GNS00 GNT00 GNU00 GLS00 GLT00 GLU00 GNH02 GNJ02 GN(10P)02 GNK02 GNL02 GLH02 GLJ02 GLK02 GLL02 GNS02 GNT02 GNU02 GLS02 GLT02 GLU02 Conductor Size (mm2) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 Stranding (mm) No. Of Pairs Weight (Kg/Km) Sheath Colour UKOOA Code 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 3 7 12 20 3 7 12 20 3Triple 7Triple 12Triple 3Triple 7Triple 12Triple 3 7 10 12 20 3 7 12 20 3Triple 7Triple 12Triple 3Triple 7Triple 12Triple 450 740 1120 1720 450 740 1120 1720 550 930 1450 550 930 1450 570 920 1380 1560 2260 570 920 1560 2260 690 1180 2020 690 1180 2020 GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY GREY GREY BLUE BLUE BLUE GREY GREY GREY GREY GREY BLUE BLUE BLUE BLUE GREY GREY GREY BLUE BLUE BLUE GNH00 GNJ00 GNK00 GNL00 GLH00 GLJ00 GLK00 GLL00 GNS00 GNT00 GNU00 GLS00 GLT00 GLU00 GNH02 GNJ02 GN(10P)02 GNK02 GNL02 GLH02 GLJ02 GLK02 GLL02 GNS02 GNT02 GNU02 GLS02 GLT02 GLU02 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: pairs - black , white numbered triples - black, white, red numbered. quad - black, white, red, blue numbered. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 122 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. Marine And Offshore Cables FiRe Resistant, ePR insulated indiViduallY scReened sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa Tinned stranded circular copper conductor to BS6360 class 2 Mica glass tape insulation, EPR, GP4 insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape.Each pair individually screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to BS7917/BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21 IEC60331 (BS7917). CCC Code GPF00 GMF00 GPX00 GMX00 GPH00 GMH00 GPJ00 GMJ00 GPK00 GMK00 GPL00 GML00 GPM00 GMM00 GPR00 GMR00 GPS00 GMS00 GPT00 GMT00 GPU00 GMU00 GPF01 GMF01 GPX01 GMX01 GPH01 GMH01 GPJ01 GMJ01 GPK01 GMK01 GML01 GPL01 GPM01 GMM01 GPR01 Conductor Size (mm2) 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Stranding (mm) No. Of Pairs Weight (Kg/Km) Sheath Colour UKOOA Code 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 24/0.2 7/0.4 7/0.4 7/0.4 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/0.4 1 1 1Quad 1Quad 3 3 7 7 12 12 20 20 27 27 1Triple 1Triple 3Triple 3Triple 7Triple 7Triple 12Triple 12Triple 1 1 1Quad 1Quad 3 3 7 7 12 12 20 20 27 27 1Triple 260 260 330 330 480 480 800 800 1240 1240 2040 2040 2330 2330 280 280 590 590 990 990 1640 1640 270 270 360 360 520 520 920 920 1540 1540 2450 2450 2690 2690 310 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE BLUE GREY GREY BLUE GREY GPF00 GMF00 GPX00 GMX00 GPH00 GMH00 GPJ00 GMJ00 GPK00 GMK00 GPL00 GML00 GPM00 GMM00 GPR00 GMR00 GPS00 GMS00 GPT00 GMT00 GPU00 GMU00 GPF01 GMF01 GPX01 GMX01 GPH01 GMH01 GPJ01 GMJ01 GPK01 GMK01 GML01 GPL01 GPM01 GMM01 GPR01 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: pairs - black , white numbered triples - black, white, red numbered. quad - black, white, red, blue numbered. Should not be installed at temperatures below -15°C. Table information continued on the next page... Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. 123 Marine And Offshore Cables FiRe Resistant, ePR insulated indiViduallY scReened sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa Tinned stranded circular copper conductor to BS6360 class 2 Mica glass tape insulation, EPR, GP4 insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape.Each pair individually screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to BS7917/BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21 IEC60331 (BS7917). CCC Code GMR01 GPS01 GMS01 GPT01 GMT01 GPU01 GMU01 GPF02 GMF02 GPG02 GPX02 GMX02 GPH02 GMH02 GPJ02 GMJ02 GPK02 GMK02 GPL02 GML02 GNL02 GPM02 GMM02 GPR02 GMR02 GPS02 GMS02 GPT02 GMT02 GPU02 GMU02 GPF03 GMF03 Conductor Size (mm2) 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 2.50 2.50 Stranding (mm) No. Of Pairs Weight (Kg/Km) Sheath Colour UKOOA Code 7/0.4 7/.04 7/.04 7/.04 7/.04 7/.04 7/.04 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.53 7/0.67 7/0.67 1Triple 3Triple 3Triple 7Triple 7Triple 12Triple 12Triple 1 1 2 1Quad 1Quad 3 3 7 7 12 12 20 20 20 27 27 1Triple 1Triple 3Triple 3Triple 7Triple 7Triple 12Triple 12Triple 1 1 310 630 630 1100 1100 1840 1840 300 300 410 410 410 600 600 1030 1030 1750 1750 2640 2640 2640 2970 2970 330 330 730 730 1220 1220 2150 2150 340 340 BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GMR01 GPS01 GMS01 GPT01 GMT01 GPU01 GMU01 GPF02 GMF02 GPG02 GPX02 GMX02 GPH02 GMH02 GPJ02 GMJ02 GPK02 GMK02 GPL02 GML02 GNL02 GPM02 GMM02 GPR02 GMR02 GPS02 GMS02 GPT02 GMT02 GPU02 GMU02 GPF03 GMF03 Temperature limits: -15 to +90°C. *Bending radius: 6 x overall diameter. Core identification: pairs - black , white numbered triples - black, white, red numbered. quad - black, white, red, blue numbered. Should not be installed at temperatures below -15°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances. 124 *All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities of their cable, it is not a specification defined in standards. SECTION 12 Installation Accessories 125 FRaMinG and suPPoRt sYsteMs AvAILABLE IN HOT DIP GALvANISED OR STAINLESS STEEL 126 AvAILABLE IN HOT DIP GALvANISED OR STAINLESS STEEL *These items require a separate M10X40 cone bolt 127 lMl LML Products Limited Since its inception in 1968, LML has designed, manufactured and supplied a comprehensive range of copper tube terminals including bespoke specials. With in-house tooling and electroplating facilities, LML will always provide a solution for its quality focused customers in compliance with BS EN ISO 9001:2000 Copper Tube Terminals LML terminals are manufactured from seamless copper tube to BS EN 12449 and feature bell mouth entry up to 400mm2 and chamfered entry from 500mm2 to 1000mm2. All terminals and splices (other than parallel splices) are provided with an inspection hole to ensure the conductor is fully inserted before crimping. Internal barrel diameters suit standard cables as defined in BS EN 6360. Standard finish is bright electro tin plating to BS EN 1872. Other finishes can be provided, e.g. nickel or silver. Terminals are independently tested to comply with BS EN 61238-1, and are also approved for military use and by London Underground. Crimp Tooling LML Products also supply a large range of manual hydraulic tools for crimping terminals from 1.5mm2 to 1000mm2. LML also supplies a range of hydraulic crimping tools with rechargeable battery. Med/High Voltage Crimp Terminals LML Products manufactures a range of copper tube terminals to suit 11kv and 33kv. We also manufacture water blocked splices and terminals. Tel: 01642 217341 Fax: 01642 253723 email: sales@bilcourt.co.uk www.bilcourt.co.uk • Cables & leads • Cable management • Heating & ventilation • Distribution, switchgear & enclosures • Lamps • Lighting products • Security & emergency • Site equipment, tools & fixings • Wiring accessories Middlesbrough Branch Newcastle Branch Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: Sales 01642 241133 / Admin 254234 Fax: Sales 01642 226171 / Admin 226474 Email: sales@clevelandcable.com Website: www.clevelandcable.com Fisher Street Industrial Estate, Walker, Newcastle Upon Tyne NE6 4LT Tel: 0191 263 3363 Fax: 0191 263 0601 Email: newcastle@clevelandcable.com Bristol Branch 2 Bishops Court, Calver Road, Winwick Quay, Warrington WA2 8QY Tel: 01925 655383 Fax: 01925 655989 Email: warrington@clevelandcable.com St. Georges Industrial Estate, St. Andrews Road, Avonmouth, Bristol BS11 9HS Tel: 01179 382222 Fax: 01179 382220 Email: bristol@clevelandcable.com Glasgow Branch 56 Clydesmill Road, Cambuslang Investment Park, Cambuslang, Glasgow G32 8RE Tel: 0141 646 5000 Fax: 0141 646 5001 Email: glasgow@clevelandcable.com Milton Keynes Branch 7 Fitzhamon Court, Wolverton Mill South, Milton Keynes MK12 6LB Tel: 01908 221414 Fax: 01908 221661 Email: miltonkeynes@clevelandcable.com Warrington Branch Bilcourt Electrical Distributors Ltd Riverside Park Road, Middlesbrough, Cleveland TS2 1QW Tel: 01642 217341 Fax: 01642 253723 Email: sales@bilcourt.co.uk Aberdeen Office Westhill Business Centre, Arnhall Business Park, Westhill, Aberdeen AB32 6UF Tel: Sales 01224 330565 Fax: Sales 01224 330564 Email: aberdeen@clevelandcable.com London Branch Designed by ure orthDesign.com Crabtree Manorway South, Belvedere, Kent DA17 6AB Tel: 0208 311 4141 Fax: 0208 320 5454 Email: london@clevelandcable.com