A WORLD POWER IN CABLE SUPPLY

advertisement
A WORLD POWER IN CABLE SUPPLY
www.clevelandcable.com
Distribution Centres
CLEvELAND CABLE LOCATIONS
2
As is illustrated within our catalogue, we stock a comprehensive range of cables for every
conceivable application. All types shown are considered as standard items to our range and are always available for immediate delivery. Our stocks are extremely large and unrivalled in the industry. We are fortunate to have a very experienced and dedicated team of people who are able to assist and advise. Additionally our policy of continuing investment in the best available
technology, warehousing, handling and measuring equipment and delivery vehicles enables us to guarantee all our customers an extremely high quality service.
Enquiries are welcome from customers worldwide. Our export service is efficient and reliable
with the ability to ship by air or sea freight to any destination.
Please feel free to contact the distribution centre of your choice for an
immediate, professional and trouble free service.
Middlesbrough
Bristol
Glasgow
Milton Keynes
01642 241133
01179 382222
0141 646 5000
01908 221414
London
Newcastle
Warrington
Aberdeen
0208 311 4141
0191 263 3363
01925 655383
01224 330565
3
Cleveland Cable Company, established in 1978, is
undoubtedly the foremost distributor of electrical
cables in Great Britain and possibly Europe.
The Head Office and principal stocking location is located at Middlesbrough in the North East of
England. This site covers an area of twelve acres and includes over 160,000 square feet of
warehousing. Additionally there are regional depots at Bristol, Glasgow, London, Milton Keynes,
Newcastle and Warrington. Each location holds comprehensive stocks and is equipped with the
most modern handling and measuring equipment. Deliveries are made by our own fleet of
purpose-designed vehicles, all of which are fitted with hydraulic lifting equipment for safe
offloading onsite and also efficient collection of empty drums.
4
Middlesbrough Head Office
Warehouses and Stockyard
5
Gland Selection Guidelines
Gland selection Guidelines
There are many factors to be considered when
selecting cable glands for industrial installations.
Neglecting to give due attention to these factors
could cause unnecessary difficulties at a crucial
point in time where most inconvenience and
expense can result. It is most desirable to avoid
discovering that, once all other equipment is on site
or installed, the glands have not been ordered or
are the wrong size or type.
Good practice would be to allocate some planning and
preparation time to cable gland selection. This will help
avoid the possible disruption which could result at a
critical point of the installation process. In the event of
a project schedule of cables being available Cleveland
Cable Company are happy to offer a gland selection
and sizing service. Please contact any of our depots
for further information or assistance.
Here is a summary of some aspects to carefully
consider when selecting cable glands.
• Identify the type of cable to be used.
• Check the construction, size and material
properties of the cable.
• Check the type and material of the cable armour
(*)
• Check the short circuit fault current rating of the
cable armour (**)
• Check the actual diameter of the inner bedding
(where present) against this catalogue.
• Check the actual diameter of the lead covering
(where present) against this catalogue.
• Check the actual size of the overall cable
diameter against this catalogue.
• Check the size and type or armour or braid
(where present) against this catalogue.
• Check any special environmental requirements in
relation to corrosion protection.
• Check the material of the mating electrical
enclosures to eliminate dis-similar metals.
• Consider whether any protective plating is
required to be applied to the cable gland.
6
• Check the type and size of the cable entry hole
in the mating electrical equipment.
• Check the ingress protection rating of the
electrical equipment or site standard.
• Check whether a single or double seal cable
gland is required.
• Check whether an entry thread seal is required
for IP66 (or IP67/IP68) conditions.
• Check whether fixing accessories such as
locknuts and serrated washers are required.
• Check whether earth tags are required. (**)
• Check whether shrouds are required.
• Select a corresponding cable gland type from this catalogue.
• For installations in Hazardous Areas, special
considerations should be taken into account to
ensure compliance with national or international
codes of practice.
• Check whether a thread conversion adaptor or
reducer is required to make the installation.
• Select corresponding adaptors or reducers from this catalogue.
• Check whether any stopper plugs are required
to close unused cable entries.
• Select corresponding stopper plugs from this catalogue.
Note (*): If the cable armour is of a non standard
material, i.e. Aluminium Wire Armour, it may be
necessary to consider an alternative cable gland
material, e.g. Aluminium.
Note (**): For certain medium voltage and high
voltage cables where the fault current carrying
capacity of the cable armour is greater than that of
the standard earth tag it may be necessary to
consider a cable gland utilising the a heavy Cast
Integral Earth Lug (CIEL) option which can be
identified in the body of this catalogue.
Cable Sections
SECTION 1 Low Voltage PVC Fixed Wiring & Mains Cables
6491X (HO7v-R) PvC insulated wiring, 1.5mm2 – 630mm2 ............................................................................................................................12 Bare copper strand, soft drawn to BS6360/81, 6mm2 – 400mm2 ............................................................................................................12
6181Y PvC insulated, PvC sheathed surface wiring, 1.0mm2 – 120mm2 ..................................................................................................13 624*Y PvC insulated, PvC sheathed surface wiring, 1mm2 – 16mm2........................................................................................................13 BS5467 Mains & control, XLPE, PvC SWA, PvC, 1.5mm2 – 16mm2 including multicores............................................................14 BS5467 Mains, XLPE, PvC, SWA, PvC, copper conductors, 25mm2 – 400mm2 ............................................................................15 BS5467 Mains, XLPE, PvC, SWA, MDPE, copper conductors 4mm2 – 16mm2 ..................................................................................16
BS5467 Mains, XLPE, PvC, SWA, MDPE, copper conductors 25mm2 – 400mm2 ..........................................................................17
BS5467 Mains, XLPE, PvC, SWA, PvC, aluminium conductors, 25mm2 – 300mm2 ......................................................................18 BS7889 Mains, single core, XLPE, PvC, non-armoured, 50mm2 –1000mm2 ......................................................................................18 BS5467 Mains, single core, XLPE, PvC, aluminium wire armoured, PvC, 50mm2 – 1000mm2 ..............................................19
Mines & Quarries Mains, XLPE, PvC, SWA, PvC, with 60% Conductivity in armour, 10mm2 – 300mm2 ........................20
EEMUA 133 Multicore, XLPE, lead sheathed, PvC, SWA, PvC, Control cable for petro-chemical industries, 1.5mm2 – 4mm2....................................................................................................................................................................................................21
EEMUA 133 Mains, XLPE, lead sheathed, PvC,SWA, PvC, for petro-chemical industries, 1.5mm2 – 16mm2..................22 EEMUA 133 Mains, XLPE, lead sheathed, PvC, SWA, PvC, for petro-chemical industries, 25mm2 – 300mm2 ..........23 NYY non-armoured Mains Cable 1.5mm2 - 16mm2 ..............................................................................................................................................24
Cathodic Protection Cables. XLPE, PvC, and XLPE, PvC, SWA, PvC, 6mm2 – 185mm2............................................................25 Concentric, split & straight, single phase service cable, 4mm2 – 35mm2..............................................................................................26
SECTION 2 3300V Mains Cables
BS5467 Mains, single core XLPE, PvC, aluminium wire armoured, PvC, 3300v, 120mm2 – 630mm2 ..............................28 BS6724 Mains, single core XLPE, LSZH, aluminium wire armoured, LSZH, 3300v, 120mm2 – 630mm2 ........................28 BS5467 Mains three core, XLPE, PvC, SWA, PvC, 3300v, 16mm2 – 400mm2 ................................................................................29 BS6724 Mains three core, XLPE, LSZH, SWA, LSZH, 3300v, 16mm2 - 300mm2 ............................................................................29
Mines & Quarries Mains, XLPE, PvC, SWA, PvC, with 60% conductivity in armour, 3300v, 16mm2 – 300mm2........30
EEMUA 133 Mains, XLPE, Lead sheathed, PvC, SWA, PvC, for petro-chemical industries, 3300v, 25mm2 – 300mm2 ................................................................................................................................................................................................30
SECTION 3 LSZH Fixed Wiring & Mains
6491B (H07Z-R) LSZH insulated wiring, 1.5mm2 – 630mm2 ........................................................................................................................32 6181B XLPE insulated, LSZH sheathed, surface wiring, 1.5mm2 – 35mm2 ............................................................................................33 624*B XLPE insulated, LSZH sheathed surface wiring 1.5mm2 – 16mm2 ..............................................................................................33 BS6724 Mains & control, XLPE, LSZH, SWA, LSZH, 1.5mm2 – 16mm2 including multicores ...................................................34 BS6724 Mains, XLPE, LSZH, SWA, LSZH, 25mm2 – 400mm2 ....................................................................................................................35 BS6724 Mains, single core, XLPE, LSZH, 50mm2 – 1000mm2 ....................................................................................................................36 BS6724 Mains, single core, XLPE, LSZH, aluminium wire armoured, LSZH, 50mm2 – 1000mm2 ........................................37 BS8436 Protected fixed wiring cable, 1mm2 – 10mm2 ......................................................................................................................................38
7
Cable Sections
SECTION 4 Medium Voltage 11000V & Above
BS6622 Mains, single core, XLPE, CTS, PvC, aluminium wire armoured, PvC, 11000v, 50mm2 – 630mm .................40 BS6622 Mains, three core, XLPE, CTS, PvC, SWA, PvC, 11000v, 25mm2 – 400mm2 ................................................................40 BS6622 Mains, three core, aluminium conductor XLPE, CTS, PvC, SWA, PvC, 11000v, 95mm2 – 300mm2 ................41
Triplex, BS7870, aluminium conductor XLPE, CTS,MDPE, 11000v, utility cable, 70mm2 – 300mm2..................................41
Paper insulated, BS6480 Mains, three core, SWA, PvC, 11000v, 25mm2 – 400mm2 ..................................................................42 BS7835 Mains, single core, XLPE, CTS, LSZH, aluminium wire armoured, LSZH, 11000v, 50mm2 – 630mm2 ..........43 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 11000v, 35mm2 – 400mm2 ............................................................43 BS7835 Mains, three core, XLPE, CTS, LSZH, SWA, LSZH, 22000v and 33000v, 95mm2 – 185mm2 ............................44
SECTION 5 High voltage 33000v Service And Windfarm Cables
BS7870 Mains, single core, aluminium conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2............................46 BS7870 Mains, single core, copper conductors , XLPE, CWS, MDPE, 33000v 70mm2 – 630mm2 ..................................46
SECTION 6 Fire Protection, Alarm & Security Cables
Mineral Insulated........................................................................................................................................................................................................................48 BS5839/BS7629 Fire performance alarm and security cable, 1mm2 – 4mm2 ..................................................................................49 BS5839/BS7629 Enhanced fire performance alarm and security cable 1.5mm2 – 4mm2 ........................................................50
BS6387 Fire performance single core cable, 1.5mm2 – 16mm2 ..................................................................................................................50
BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant,1.5mm2 – 16mm2, including multicores ............................................................................................................................................51
BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, 25mm2 – 400mm2 ........................................52 BS6387/BS7846 Mains and control, mica tape, XLPE, LSZH,SWA, LSZH, fire resistant, enhanced, 1.5mm2 – 16mm2, including multicores. ..............................................................................................................................................53
BS6387/BS7846 Mains, mica tape, XLPE, LSZH, SWA, LSZH, fire resistant, enhanced, 25mm2 – 400mm2 ...............54 SECTION 7 Flexible Cables, PVC and Rubber
PVC and LSZH flexible cables
PvC flexible cables 218*Y (H03vv-F) PvC, PvC, 0.5mm2 – 0.75mm2 ..................................................................................................56 318*Y (H05vv-F) PvC, PvC, 0.5mm2 – 2.5mm2 ....................................................................................................................................................56 309*Y Heat resisting PvC, PvC, 0.5mm2 – 2.5mm2 ............................................................................................................................................57 Arctic grade low temperature flex, 1.5mm2 – 6mm2 ..........................................................................................................................................57 318*B (H05ZIZI-F) LSZH, LSZH, 0.75mm2 – 2.5mm2 ........................................................................................................................................58
8
Cable Sections
YY Control cable, 0.75mm2 – 1.5mm2 ..........................................................................................................................................................................59 YY Control cable, 2.5mm2 – 50mm2 ............................................................................................................................................................................60 SY Control cable, 0.75mm2 – 2.5mm2 ..........................................................................................................................................................................61
SY Control cable, 4.0mm2 – 95mm2 ............................................................................................................................................................................62 CY Control cable, 0.5mm2 – 16mm2 ..............................................................................................................................................................................63
YY Control cable, LSZH, 0.75mm2 – 25mm2 ..........................................................................................................................................................64 CY Control cable, LSZH, 0.75mm2 – 1.5mm2 ..........................................................................................................................................................64
SY Control Cable, LSZH, 1.5mm - 6mm2 ....................................................................................................................................................................65
Tri-rated and Bi-rated BS6231, switchgear and control panel wire, 0.5mm2 – 400mm2 ..........................................................66 2491B/6701B (H05Z-K), flexible conductor, LSZH insulated wiring, 1.5mm2 – 240mm2 ............................................................66
6381Y PvC, PvC, 6mm2 – 400mm2 ..............................................................................................................................................................................67
Solar Energy Cables 1.5mm2 – 35mm2 ........................................................................................................................................................................67
Rubber flexible cables
BS6500 EPR insulated, CSP sheathed, flexible power & control, 0.75 – 2.5mm2 ..........................................................................68 BS7919 EPR insulated, CSP sheathed, flexible mains 4mm2 – 16mm2 ....................................................................................................69 BS7919 EPR insulated, CSP sheathed, flexible mains, 25mm2 – 630mm2 ..........................................................................................70 HO7RN-F EPR insulated, PCP sheathed, flexible mains, 1.0mm2 – 50mm2 ........................................................................................71
HO7RN-F EPR insulated, PCP sheathed, flexible mains, 70mm2 – 630mm2 ....................................................................................72 380*P EPR insulated, copper braided screen, PCP sheathed, flexible mains, 1mm2 – 16mm2 ................................................73 BS6500 EPR insulated, TR sheathed, flexible power & control 0.75mm2 – 2.5mm2 ....................................................................73 Coil lead BS6195 EPR, CSP, 0.5mm2 – 400mm2 ...................................................................................................................................................74 Welding cable, O361TQ EPR, CSP, 16mm2 – 185mm2 ........................................................................................................................................75
Flatform and silicon cables
Flatform cable, EPR, PCP, 1.5mm2 – 70mm2 ............................................................................................................................................................75
Flatform cable, PvC, PvC, 1.5mm2 – 95mm2............................................................................................................................................................76 Silicon insulated, silicon sheathed, flexible cable, 0.75mm2 – 2.5mm2 ....................................................................................................76
SECTION 8 Instrumentation, Control & Communication Cables
BS5308 Control and instrumentation cable, non-armoured with collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2. ............................................................................................................................................................78
BS5308 Control and instrumentation cable, non-armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2............................................................................................................................79 BS5308 Control and instrumentation cable, armoured with collective screen, 0.5mm2 – 2.5mm2, part 1 and part 2 ..80
BS5308 Control and instrumentation cable, armoured with individual and collective screen, 0.5mm2 – 1.5mm2, part 1 and part 2 ............................................................................................................................81
BS5308 Control and instrumentation non armoured with collective screen LSZH, 0.75mm to 1.5mm part 1 ............82
BS5308 Control and instrumentation non armoured with individual and collective screen LSZH, 0.5mm to 0.75mm part 1 ....................................................................................................................................82
BS5308 Control and instrumentation armoured with collective screen LSZH, 0.5mm to 2.5mm part 1........................83
BS5308 Control and instrumentation armoured with individual and collective screen LSZH, 0.5mm to 1.5mm part 1........83
BS5308 Control and instrumentation cable, lead sheathed, armoured with collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2 ..................................................................................................................................84 BS5308 Control and instrumentation cable, lead sheathed, armoured with individual and collective screen, 0.75mm2 – 1.5mm2, part 1 and part 2..................................................................................................85
BS5308 part 1 core identification ..................................................................................................................................................................................86 BS5308 part 2 core identification ..................................................................................................................................................................................87
British Steel specification CES20 type 134, 0.75mm2........................................................................................................................................88
British Steel specification CES20 type 143, 0.75mm2........................................................................................................................................89
CW1308 telephone cable....................................................................................................................................................................................................90
Telephone cable to ENATS 09-6 standard................................................................................................................................................91/92/93
Utility Industry PvC Control Cables, ENATS 09-6 2.5mm2 ............................................................................................................................93
ENATS 09-6 section 3.6 core identification............................................................................................................................................................94 9
Cable Sections
ENATS 09-6 section 4.5 core identification............................................................................................................................................................94 Petroleum jelly filled telephone cable to CW1128, CW1128/1198 and BS3573 ..................................................................................95 Defence standard screened cable type 61-12 PvC and LSZH ....................................................................................................................96 Defence standard 61-12 parts 4 & 5 core identification ...................................................................................................................................97 Thermocouple extension and compensating cable, 0.75mm2 ....................................................................................................................98 Thermocouple core identification..................................................................................................................................................................................99 Traffic signal cable, loop feeder cable and loop detector cable ........................................................................................100/101/102 SECTION 9 Data Cables
Belden equivalents ................................................................................................................................................................................................................104
Coaxial cables............................................................................................................................................................................................................................104
Cat 5 data cables....................................................................................................................................................................................................................104
Cat 6 data cables....................................................................................................................................................................................................................104
SECTION 10 Railway Cables
Signalling cable types A1, A2, A3, B1 and B2, 0.75mm2 – 95mm2 ..........................................................................................................106 Signalling cable types C1, C2, C3, D1, D2, D3, E1, E2 and E3, 0.75mm2 – 35mm2 ............................................................................107
Train protection warning system cable ....................................................................................................................................................................108 Point heater cable ..................................................................................................................................................................................................................108 Axle counting cable ..............................................................................................................................................................................................................109 Datalink cable ............................................................................................................................................................................................................................110
Fixed Telephone Network (FTN) copper trackside cable ............................................................................................................................1 1 1
Power cables, 16mm2 – 95mm2 ......................................................................................................................................................................................112
Trackfeeder cables, 150mm2 – 1000mm2 ................................................................................................................................................................112
SECTION 11 Marine And Offshore Cables
UKOOA Cable Identifier ......................................................................................................................................................................................................114
EPR insulated, non-armoured shipwiring cable, 1.5mm2 –6mm2 ..............................................................................................................115
EPR insulated, non-armoured shipwiring cable, 10mm2 – 630mm2 ......................................................................................................116
EPR insulated, braided armoured shipwiring cable, 1.5mm2 – 4mm2 ....................................................................................................117
EPR insulated, braided armoured shipwiring cable, 6mm2 – 300mm2 ................................................................................................118
EPR insulated, single core braided shipwiring cable, 6mm2 – 630mm2 ..............................................................................................119
MICA, EPR insulated, braided armoured shipwiring cable 1.5mm to 10mm ....................................................................................119
EPR insulated instrumentation cable, braided armoured with collective screen 0.75mm to 1.5mm ..............................120
EPR insulated instrumentation cable, braided armoured with individual screen 0.75mm to 2.5mm ....................................121
MICA, EPR insulated instrumentation cable, braided armoured with collective screen 0.75mm to 1.5mm................122
MICA, EPR insulated instrumentation cable, braided armoured with individual screen 0.75mm to 2.5mm......123/124
SECTION 12 Installation Accessories ..............................................................................................125
10
Low voltage PvC Fixed Wiring & Mains Cables
SECTION 1 Low voltage PvC Fixed Wiring & Mains Cables
Low voltage PvC Fixed Wiring & Mains Cables
6491X (Ho7V-R) PVc
Stranded plain annealed compacted circular copper conductor, PvC outer sheath. Ref 6491X.
Harmonised code HO7v-R. 450/750 volts grade to BS6004. Flame propagation to BS EN 50265.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Brass A2
Nylon A2
6491X1/5
6491X2/5
6491X4
6491X6
6491X10
6491X16
6491X25
6491X35
6491X50
6491X70
6491X95
6491X120
6491X150
6491X185
6491X240
6491X300
6491X400
6491X500
6491X630
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50
21
35
50
71
120
180
280
380
510
720
990
1200
1500
1900
2500
3000
3950
4950
6250
3.00
3.65
4.20
4.75
6.15
7.10
8.90
9.95
11.70
13.35
15.60
17.20
19.10
21.30
24.30
27.05
30.35
32.80
36.50
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
20
25
25
25
32
32
40
40
50S
50S
16
16
16
16
16
16
20
20
20
25
25
25
32
32
32
40
40
50
50
Temperature limits: -15 to +70°C.
*Bending radius: up to 10mm2
- 3 x overall diameter. above
25mm2 - 6 x overall diameter.
Standard colours available: 1.5mm2 & 2.5mm2 - Brown, Black, Grey, Blue,
Green/Yellow, White, Orange,
Turquoise, violet, Pink
4mm2-630mm2 - Brown,
Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0°C or above +60°C.
BaRe coPPeR stRand
Stranded plain annealed compacted circular copper conductor, non insulated and non sheathed.
450 volts grade, soft drawn to BS6360/81.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
CB006
CB010
CB016
CB025
CB035
CB050
CB070
CB095
CB120
CB150
CB185
CB240
CB300
CB400
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
58
96
154
240
336
480
672
912
1152
1440
1776
2304
2800
3750
3.0
4.2
5.1
5.9
7.8
8.8
9.8
12.5
12.8
14.4
16.1
19.8
20.6
26.4
Temperature limits:
- 15 to + 70°C.
*Bending radius:
Up to 10mm - 3 x overall diameter.
Above 25mm - 6 x overall
diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
12
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
suRFace WiRinG caBles PVc 6181Y
Plain annealed stranded circular copper conductor, single core, PvC insulated, PvC sheathed, Ref 6181 Y. 300/500 volts grade to BS6004 120mm rated at 600/1000 v. Brown/Grey or Blue/Grey.
Flame propagation to BS EN 50265.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6181Y1
6181Y1/5
6181Y2/5
6181Y4
6181Y6 6181Y10
6181Y16
6181Y25
6181Y35
6181Y50
6181Y70
6181Y95
6181Y120
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19.2.52
37/2.03
1
1
1
1
1
1
1
1
1
1
1
1
1
Weight
Overall
(Kg/Km) Diameter
(mm)
28
36
51
75
98
150
220
340
440
540
750
1010
1250
4.5
5.1
6.0
6.8
7.4
8.8
10.5
12.5
13.5
14.38
15.3
17.7
19.3
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
25
32
0.5
0.5
0.6
0.6
0.7
0.7
0.8
Temperature limits:
-15 to +70°C.
•Bending radius:
up to 10mm2 - 3 x overall
diameter. over 10mm2 - 4
x overall diameter.
Should not be installed at
temperatures below 0°C
or above +60°C.
suRFace WiRinG caBles PVc 624*Y
Plain annealed copper conductor, PvC insulated one, two or three cores laid flat with an
uninsulated circuit protective conductor and PvC sheathed. Grey. Ref 6241/2/3Y 300/500 v to
BS6004. Flame propagation to BS EN 50265.
CCC
Code
Conductor
Size
(mm2)
6241Y1BR
1.0
6241Y1/5BR
1.5
6242Y1
1.0
6242Y1/5
1.5
6242Y1/5BRBR 1.5
6242Y2/5
2.5
6242Y4
4.0
6242Y6
6.0
6242Y10
10.0
6242Y16
16.0
6243Y1
1.0
6243Y1/5
1.5
6243Y2/5
2.5
Stranding
(mm)
No. Of
Cores
CPC
Size
(mm2)
Weight
(Kg/Km)
Overall
Diameter
(mm)
1/1.13
1/1.37
1/1.13
1/1.38
1/1.38
1/1.77
7/0.85
7/1.04
7/1.35
7.1.70
1/1.13
1/1.37
1/1.77
1
1
2
2
2
2
2
2
2
2
3
3
3
1.0
1.0
1.0
1.0
1.0
1.5
1.5
2.5
4.0
6.0
1.0
1.0
1.5
49
51
69
85
85
120
175
240
390
560
92
115
170
4.15 X 5.40
4.65 X 5.80
4.10 X 8.65
4.55 X 8.80
4.55 X 8.80
5.40 X 10.50
6.10 X 12.00
6.90 X 13.80
8.40 X 18.50
9.70 X 20.60
4.60 X 10.20
4.75 X 11.45
5.45 X 13.40
Temperature limits:
- 15 to + 70°C.
*Bending radius:
Up to 10mm - 3 x overall diameter.
Above 10mm - 6 x overall
diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
13
Low voltage PvC Fixed Wiring & Mains Cables
Mains and contRol caBles PVc
Stranded plain annealed copper conductors, XLPE insulated, PvC bedding, galvanised steel wire armour,
PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
XLPE2X1/5
XLPE3X1/5
XLPE4X1/5
XLPE5X1/5
XLPE7X1/5
XLPE8X1/5
XLPE10X1/5
XLPE12X1/5
XLPE19X1/5
XLPE27X1/5
XLPE37X1/5
XLPE48X1/5
XLPE2X2/5
XLPE3X2/5*
XLPE4X2/5
XLPE5X2/5
XLPE7X2/5
XLPE10X2/5
XLPE12X2/5
XLPE19X2/5
XLPE27X2/5
XLPE37X2/5
XLPE48X2/5
XLPE2X4
XLPE3X4*
XLPE4X4
XLPE5X4
XLPE7X4
XLPE12X4
XLPE19X4
XLPE27X4
XLPE2X6
XLPE3X6*
XLPE4X6
XLPE5X6
XLPE7X6
XLPE2X10
XLPE3X10*
XLPE4X10
XLPE5X10
XLPE7X10
XLPE2X16
XLPE3X16*
XLPE4X16
XLPE5X16
XLPE7X16
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70
2
3
4
5
7
8
10
12
19
27
37
48
2
3
4
5
7
10
12
19
27
37
48
2
3
4
5
7
12
19
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
Weight
Overall
(Kg/Km) Diameter
(mm)
234
271
306
356
391
501
650
657
863
1310
1590
1900
312
343
392
463
509
850
861
1324
1760
2185
2800
373
421
496
573
741
1255
1690
2250
450
515
696
808
1100
590
781
927
1095
1500
893
1059
1269
1679
2150
11.06
11.54
12.26
13.23
14.1
16.7
18
18.3
20.78
25.1
27.5
30
12.4
12.99
13.86
14.92
15.96
20
21.11
25.16
30
33
36
13.38
14.05
15.04
16.35
18.21
24.24
27.61
32
14.38
15.14
17.03
18.39
21.9
16.18
17.76
19.09
20.91
25
19.06
20.35
21.95
25.19
28.1
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20/16
20/16
20S
20S
20
20
20
25
25
32
32
20S
20S
20S
20S
20
25
25
25
32
40
40
20S
20S
20
20
20
25
32
32
20S
20
20
20
25
20
20
25
25
25
25
25
25
25
32
0.5
0.5
0.5
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.1
1.2
0.5
0.6
0.6
0.6
0.8
0.8
0.9
1.0
1.2
1.4
1.6
0.6
0.6
0.6
0.7
0.8
1.0
1.1
1.4
0.6
0.7
0.7
0.8
0.9
0.7
0.8
0.8
0.9
1.0
0.8
0.9
0.9
1.1
1.2
Temperature limits: -15 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification: 2 core - Brown, Blue.
3 core - Brown, Black,
Grey.
4 core - Brown, Black,
Grey, Blue.
5 core and above - up to
6mm2 - White with Black
numbers.
5 core - 10mm2 and
16mm2 - Brown, Black,
Grey, Blue, Green/Yellow
1.5 & 2.5 - 2,3,4 core also
available in white
numbered cores to ESI
09-6.
Should not be installed at
temperatures below 0°C
or above +60°C.
* Additionally these
cables are stocked with
Brown, Blue and
Green/Yellow core
identification.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
14
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
Mains caBles PVc
Stranded plain annealed copper conductors, XLPE insulated, PvC bedding, galvanised steel wire armour,
PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6942X25
6943X25
6944X25
6945X25
6942X35
6943X35
6944X35
6945X35
6942X50
6943X50
6944X50
6945X50
6942X70
6943X70
6944X70
6945X70
6942X95
6943X95
6944X95
6945X95
6942X120
6943X120
6944X120
6942X150
6943X150
6944X150
6942X185
6943X185
6944X185
6942X240
6943X240
6944X240
6942X300
6943X300
6944X300
6942X400
6943X400
6944X400
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400
400
7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
61/2.85
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
1050
1500
1800
2200
1400
1800
2200
2800
1750
2250
2850
3850
2200
3000
4100
5100
3000
4150
5200
7700
3600
4950
6700
4250
6300
7900
5500
7650
9650
6900
9650
12400
8200
11550
14800
10100
14350
19300
20
23
25
29
22
26
28
33
25
28
31
38
28
32
37
43
32
37
40
52
35
40
46
37
45
49
43
49
55
48
56
62
50
59
66
56
65
75
Gland
Size
(mm)
Nylon
Cleat
Size
25
25
32
32
25
32
32
40
32
32
32
40
32
32
40
50S
40
40
50S
50
40
50S
50
40
50
50
50
50
63S
50
63S
63
50
63
75S
63S
75S
75
0.8
1.0
1.0
1.2
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.8
TC9
1.4
1.8
2.0
1.6
1.8
2.0
1.8
2.0
TC9
2.0
TC9
TC10
2.0
TC10
TC11
TC9
TC11
TC12
Temperature limits: -15 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
5 core - Brown, Black, Grey,
Blue,Green/Yellow.
Should not be installed at
temperatures below 0°C or above +60°C.
nB 5 coRe 95MM
and aBoVe aRe
ManuFactuRed
to iec60502-1
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
15
Low voltage PvC Fixed Wiring & Mains Cables
FiXed WiRinG and Mains caBles MdPe sHeatHed
Stranded plain annealed copper conductor, XLPE insulated, PvC bedding, galvanised steel wire
armour, MDPE outer sheath. Black. 600/1000v grade generally to BS5467.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6942PE4
6943PE4
6944PE4
6942PE6
6943PE6
6944PE6
6942PE10
6943PE10
6944PE10
6942PE16
6943PE16
6944PE16
6945PE16
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
7/0.86
7/0.86
7/0.86
7/1.06
7/1.06
7/1.06
7/1.36
7/1.36
7/1.36
7/1.74
7/1.74
7/1.74
7/1.74
2
3
4
2
3
4
2
3
4
2
3
4
5
Weight
Overall
(Kg/Km) Diameter
(mm)
344
389
462
418
480
655
552
739
881
847
1006
1211
1606
13.4
14.1
15.0
14.4
15.1
17.0
16.2
17.8
19.1
19.1
20.4
22.0
25.2
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20S
20S
20S
20
20
20
25
20
25 25
25
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
Temperature limits: - 15 to + 90°C.
Bending radius: 8 x Overall
Diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
also available in Brown, Blue, Green/Yellow.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0°C or above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
16
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
FiXed WiRinG and Mains caBles MdPe sHeatHed
Stranded plain annealed copper conductor, XLPE insulated, PvC bedding, galvanised steel wire
armour, MDPE outer sheath. Black. 600/1000v grade generally to BS5467.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6942PE25
6943PE25
6944PE25
6945PE25
6942PE35
6943PE35
6944PE35
6945PE35
6942PE50
6943PE50
6944PE50
6945PE50
6942PE70
6943PE70
6944PE70
6945PE70
6942PE95
6943PE95
6944PE95
6945PE95
6942PE120
6943PE120
6944PE120
6942PE150
6943PE150
6944PE150
6942PE185
6943PE185
6944PE185
6942PE240
6943PE240
6944PE240
6942PE300
6943PE300
6944PE300
6943PE400
6944PE400
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400
7/2.21
7/2.21
7/2.21
7/2.21
7/2.66
7/2.66
7/2.66
7/2.66
19/1.88
19/1.88
19/1.88
19/1.88
19/2.21
19/2.21
19/2.21
19/2.21
37/1.88
37/1.88
37/1.88
37/1.88
30/2.32
30/2.32
30/2.32
37/2.32
37/2.32
37/2.32
37/2.55
37/2.55
37/2.55
60/2.32
60/2.32
60/2.32
61/2.66
61/2.66
61/2.66
60/2.96
60/2.96
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
1162
1562
1895
2280
1606
1964
2393
2898
1654
2199
2763
3876
2174
2937
3967
5166
2987
4036
5128
6795
3561
4829
6578
4258
6268
7967
5423
7390
9403
6736
9238
11898
7896
11136
14328
13778
18669
22.2
24.9
26.8
29.5
25.5
27.2
29.5
32.4
25.9
28.6
32.1
36.4
29.2
32.3
37.4
41.7
33.2
37.0
41.6
48.6
36.4
40.5
47.0
39.4
45.8
51.5
44.3
49.9
56.2
49.2
55.1
62.4
51.3
60.3
68.4
67.9
78.8
Gland
Size
(mm)
Nylon
Cleat
Size
25
25
32
32
25
32
32
32
25
32
32
40
32
32
40
50S
32
40
50S
50
40
50S
50
40
50S
50
50S
50
63S
50
63S
63
50
63
75S
75S
90
0.9
1.0
1.1
1.2
1.1
1.1
1.2
1.4
1.1
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.8
2.0
1.6
1.6
2.0
1.6
2.0
TC9
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC10
TC11
TC11
TC14
Temperature limits:
- 15 to + 90°C.
*Bending radius: 8 x Overall
Diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
also available in Brown, Blue,
Green/Yellow.
4 core - Brown, Black, Grey, Blue.
5 core - Brown, Black, Grey, Blue, Green/Yellow.
Should not be installed at
- 15 to + 90°C temperatures
below 0°C or above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
17
Low voltage PvC Fixed Wiring & Mains Cables
Mains caBles WitH aluMiniuM conductoRs PVc
Solid plain aluminium sectoral conductors, XLPE insulated, PvC bedding, galvanised steel wire armour,
PvC outer sheath. Black. 600/1000 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
SAC4X25
SAC4X35
SAC4X50
SAC4X70
SAC4X95
SAC4X120
SAC4X150
SAC4X185
SAC4X240
SAC4X300
25
35
50
70
95
120
150
185
240
300
4
4
4
4
4
4
4
4
4
4
1235
1515
1686
2401
2905
3705
4550
5076
6104
7212
25.4
28.9
29.5
34.7
38.3
42.2
46.0
51.1
56.4
61.4
25
32
32
40
40
50S
50
50
63S
63
1.0
1.2
1.2
1.4
1.6
1.8
2.0
TC9
TC9
TC10
Temperature limits: -15 to +90°C.
*Bending radius: 8 x overall
diameter.
Core identification: Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0°C or
above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
18
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
sinGle coRe non-aRMouRed Mains caBles PVc
Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, PvC
outer sheath Black. 600/1000 volts grade to BS7889/97. Flame propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
6181X50
6181X70
6181X95
6181X120
6181X150
6181X185
6181X240
6181X300
6181X400
6181X500
6181X630
6181X800
6181X1000
50
70
95
120
150
185
240
300
400
500
630
800
1000
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
127/2.85
127/3.20
Weight Overall
(Kg/Km) Diameter
(mm)
520
720
985
1215
1515
1865
2415
3005
3810
4890
6355
8075
9860
13.5
15.5
17.5
19
21.5
23.5
26.5
29
32.5
37
42
46
53
Brass
A2
Nylon
A2
25
25
25
32
32
32
40
40
50S
50S
50
63S
63
25
25
25
32
32
32
40
40
50
50
63
-
Nylon Trefoil
Cleat Cleat
Size
0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2 376AC04
1.4 376AC06
1.6 376AC09
1.8 376AC12
2.0 376AC15
TC9 376AC19
Temperature limits: -15 to +90°C.
*Bending radius: 8 x overall
diameter.
Core identification:
Brown inner - Black outer.
Should not be installed at
temperatures below 0°C or above +60°C.
FiXed WiRinG and Mains caBles
Stranded plain annealed compacted circular copper conductors, XLPE insulated, PvC bedding,
aluminium wire armoured, PvC outer sheath. Black. 600/100 volts grade to BS5467. Flame
propagation to BS EN 60332.
CCC
Code
Conductor Stranding No. Of Weight Overall
Gland Gland Nylon
Size
(mm)
Cores (Kg/Km) Diameter Size cw Size
Cleat
2
(mm )
(mm) Ali (mm) Brass
Size
A2 (mm)
6941AX50
50.0
6941AX70
70.0
6941AX95
95.0
6941AX120
120.0
6941AX150
150.0
6941AX185
185.0
6941AX240 240.0
6941AX300 300.0
6941AX400 400.0
6941AX500 500.0
6941AX630 630.0
6941AX800 800.0
6941AX1000 1000.0
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.2
127/2.52
127/2.85
127/3.2
1
1
1
1
1
1
1
1
1
1
1
1
1
638
891
1166
1412
1800
2200
2800
3400
4450
5550
7100
9200
11270
17.70
19.60
21.50
23.10
26.00
28.00
32.00
33.00
38.00
43.00
47.00
55.00
58.80
20
25
25
25
32
32
40
40
40
50S
50
63S
63S
25
32
32
32
40
40
50S
50S
50
63S
63S
75S
75S
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.4
1.6
1.8
2.0
TC9
TC10
Trefoil
Cleat
376AC04
376AC06
376AC06
376AC10
376AC13
376AC15
376AC20
376AC22
Temperature limits: - 15 to + 90°C.
*Bending radius:
6 x Overall Diameter.
Core identification:
Brown inner - Black outer
Should not be installed at temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
19
Low voltage PvC Fixed Wiring & Mains Cables
Mains caBles FoR Mines & QuaRRies PVc
Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised
steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase,
PVC outer sheath. Black. 600/1000 volts grade generally to BS5467 and BC295. Flame propagation
to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
NCB3X10/1
NCB4X10/1
NCB3X16/1
NCB4X16/1
NCB3X25
NCB4X25
NCB3X35
NCB4X35
NCB3X50
NCB4X50
NCB3X70
NCB4X70
NCB3X95
NCB4X95
NCB3X120
NCB4X120
NCB3X150
NCB4X150
NCB3X185
NCB4X185
NCB3X240
NCB4X240
NCB3X300
NCB4X300
10
10
16
16
25
25
35
35
50
50
70
70
95
95
120
120
150
150
185
185
240
240
300
300
7/1.04
7/1.04
7/1.70
7/1.70
7/2.14
7/2.14
7/2.52
7/2.52
19/1.78
19/1.78
19/2.14
19/2.14
19/2.52
19/2.52
37/2.03
37/2.03
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
896
1038
1205
1675
1550
1880
1940
2350
2360
2950
3120
4230
4310
5390
5160
6980
6610
8300
7920
10070
9930
12680
11970
15380
18.9
20.3
23.1
26.3
26.9
29.1
29.6
32.1
28.4
31.3
32.0
36.8
36.7
40.6
40.0
45.8
45.1
49.9
49.3
54.9
54.5
61.0
59.5
66.5
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
25
25
25
32
32
32
32
32
32
40
40
50S
50S
50S
50S
50
50
63S
63S
63
63
75S
0.8
0.8
1.0
1.1
1.1
1.2
1.2
1.4
1.2
1.4
1.4
1.6
1.6
1.6
1.6
2.0
1.8
2.0
2.0
TC9
TC9
TC10
TC10
TC11
Temperature limits: -15 to +70°C.
*Bending radius:
up to 16mm2 - 6 x overall
diameter.
over 16mm2 - 8 x overall
diameter. Core identification: 3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
20
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
eeMua133 contRol caBles PVc
Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC
bedding, galvanised steel wire armour, PVC outer sheath. Cores white with black numbers.
600/1000 volts grade to BS5467 and EEMUA 133. Flame propagation to BS EN 60332-1 (IEC
60332-1), bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4
(IEC 60332-3-24 category C).
CCC
Code
Conductor Stranding
Size
(mm)
(mm2)
EEMUA2X1/5 ESI EEMUA3X1/5 ESI
EEMUA4X1/5 ESI
EEMUA5X1/5
EEMUA7X1/5
EEMUA12X1/5
EEMUA19X1/5
EEMUA27X1/5
EEMUA37X1/5
EEMUA2X2/5 ESI
EEMUA3X2/5 ESI
EEMUA4X2/5 ESI
EEMUA5X2/5
EEMUA7X2/5
EEMUA12X2/5
EEMUA19X2/5
EEMUA27X2/5
EEMUA37X2/5
EEMUA5X4
EEMUA7X4
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
No. Of
Cores
2
3
4
5
7
12
19
27
37
2
3
4
5
7
12
19
27
37
5
7
Weight
Overall
(Kg/Km) Diameter
(mm)
690
750
810
895
1072
1387
1686
2418
2850
800
870
950
1038
1180
1750
2450
3100
3720
1014
1110
15
15.5
16
16.8
17.7
22.3
24.8
30
32.7
16
16.5
17.5
18.4
20
24.5
29
33
36
20.6
21.5
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
20
20
20
25
25
32
32
20
20
20
20
20
25
32
32
40
20
25
0.6
0.7
0.7
0.7
0.7
0.9
1.0
1.2
1.4
0.7
0.7
0.7
0.8
0.8
1.0
1.2
1.4
1.6
0.9
0.9
Temperature limits: -15 to +90°C.
*Bending radius:
12 x overall diameter.
Core identification:
White with Black numbers. Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
21
Low voltage PvC Fixed Wiring & Mains Cables
eeMua133 Mains caBles PVc
Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC
bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467
and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1),
bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4
(IEC 60332-3-24 category C).
CCC
Code
EEMUA2X1/5
EEMUA3X1/5
EEMUA4X1/5
EEMUA2X2/5
EEMUA3X2/5
EEMUA4X2/5
EEMUA2X4
EEMUA3X4
EEMUA4X4
EEMUA2X6
EEMUA3X6
EEMUA4X6
EEMUA2X10
EEMUA3X10
EEMUA4X10
EEMUA2X16
EEMUA3X16
EEMUA4X16
Conductor Stranding
Size
(mm)
(mm2)
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
No. Of
Cores
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
690
750
810
800
870
950
920
1000
1110
1020
1150
1400
1250
1530
1720
1630
1880
2150
15
15.5
16
16
16.5
17.5
17.5
17.5
19
18
19
20.5
20
22
23
23
24
26
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
20
20
20
20
20
20
25
20
25
25
25
25
25
25
25
32
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.8
0.9
1.0
1.0
1.0
1.1
Temperature limits: -15 to +90°C.
*Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
22
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
eeMua133 Mains caBles PVc
Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC
bedding, galvanised steel wire armour, PVC outer sheath. Black. 600/1000 volts grade to BS5467
and EEMUA 133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1),
bunched cables to BS EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4
(IEC 60332-3-24 category C).
CCC
Code
Conductor Stranding
Size
(mm)
(mm2)
EEMUA2X25
EEMUA3X25
EEMUA4X25
EEMUA2X35
EEMUA3X35
EEMUA4X35
EEMUA2X50
EEMUA3X50
EEMUA4X50
EEMUA2X70
EEMUA3X70
EEMUA4X70
EEMUA2X95
EEMUA3X95
EEMUA4X95
EEMUA2X120
EEMUA3X120
EEMUA4X120
EEMUA2X150
EEMUA3X150
EEMUA4X150
EEMUA2X185
EEMUA3X185
EEMUA4X185
EEMUA2X240
EEMUA3X240
EEMUA4X240
EEMUA2X300
EEMUA3X300
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
7/2.14
7/2.14
7/2.14
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
No. Of
Cores
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
2094
2740
3160
2868
3205
3840
2783
3655
4530
3566
4675
6175
4678
6180
7695
5641
7390
9730
6660
9300
11530
8457
10980
14160
10286
13815
17700
16519
21173
27.1
30
32
31.9
32
34.5
28.1
33.5
37
31.1
37.5
43
35.1
42.5
47
38.5
46
53
41.8
52
58.5
47.1
56.5
65
52.3
63
65.8
64.1
71.5
32
32
32
32
32
40
32
40
40
32
40
50S
40
50S
50
50S
50
63S
50S
50
63S
50
63S
63
50
63
75S
63
75S
1.1
1.2
1.4
1.4
1.4
1.4
1.2
1.6
1.6
1.4
1.6
1.8
1.4
1.8
2.0
1.6
2.0
TC9
1.8
TC9
TC10
2.0
TC9
TC11
TC9
TC10
TC11
TC11
TC12
Temperature limits:
-15 to +90°C.
*Bending radius:
12 x overall diameter.
Core identification:
2 core - Brown, Blue
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
23
Low voltage PvC Fixed Wiring & Mains Cables
Mains and contRol caBle non aRMouRed tYPe nYY-J
Solid plain copper conductors, PVC insulated, PVC filler, PVC outer sheath. Black. 600/1000 volts
grade to IEC60502-1 and VDE 0276-603. For installation indoors and outdoors as underground, or
in cable ducts, installations with additional protection where mechanical damage is unexpected.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
NYY3X1/5
NYY4X1/5
NYY5X1/5
NYY2X2/5
NYY3X2/5
NYY4X2/5
NYY5X2/5
NYY3X4
NYY4X4
NYY5X4
NYY3X6
NYY4X6
NYY5X6
-
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10
16
16
16
16
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.78
1/1.78
1/1.78
1/1.78
1/1.78
1/2.25
1/2.25
1/2.25
1/2.25
1/2.76
1/2.76
1/2.76
1/2.76
1/3.56
1/3.56
1/3.56
1/3.56
1/4.51
1/4.51
1/4.51
1/4.51
2
3
4
5
7
2
3
4
5
7
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
157
190
220
270
299
193
240
290
350
388
267
330
400
480
329
420
510
600
498
580
751
910
684
800
1057
1257
10.50
11.00
11.80
12.80
13.70
11.30
11.90
12.8
13.9
14.9
13
13.70
14.80
16.30
14.00
14.80
16.00
17.60
16.60
17.80
19.30
21.2
18.8
20.2
22
24.20
20s
20
20
20
25
20
20
20
25
25
20
25
25
25
25
25
25
25
25
25
32
32
25
32
32
32
0.5
0.5
0.5
0.6
0.6
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.9
0.8
0.9
0.9
1.0
Temperature
limits: -30 to +70°C.
Bending radius:
15 x overall
diameter.
Core
identification
2 core - Brown,
Blue.
3 core - Brown,
Blue,
Green/Yellow
4 core - Brown,
Blue, Black,
Green/Yellow
5 core - Brown,
Blue, Black, Grey,
Green/Yellow.
Should not be
installed at - 5 to + 70°C.
Should not be
installed at
temperatures below - 5°C. Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
24
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Low voltage PvC Fixed Wiring & Mains Cables
sinGle coRe non-aRMouRed catHodic PRotection caBles PVc
Plain annealed compacted circular copper conductor, XLPE insulated, PVC outer sheath, 600/1000
volts grade generally to BS5467 & IEC 60502. Colours Black/Black or Red/Red.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
6181X6 6181X10
6181X16
6181X25
6181X35
6181X50
6181X70
6181X95
6181X120
6181X150
6181X185
6
10
16
25
35
50
70
95
120
150
185
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
105
150
210
305
395
515
725
1230
1355
1695
2110
7.2
8.1
9.0 10.6
11.6
13.0
14.9
17.5
19.2
21.3
23.4
20/16
20/16
20S
20S
20
20
25
25
32
32
32
Temperature limits: -15 to +90°C.
*Bending radius:
4 x overall diameter.
Should not be installed at
temperatures below 0°C or above +60°C.
Core identification
Black inner – Black outer.
Red inner – Red outer.
sinGle coRe aRMouRed catHodic PRotection caBles PVc
Plain annealed compacted circular copper conductor, XLPE insulated, PVC bedding, galvanised steel
wire armour, PVC outer sheath. Black. 600/1000 volts grade generally to IEC 60502 & BS5467.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
6941X6 6941X10
6941X16
6941X25
6941X35
6941X50
6941X70
6941X95
6941X120
6941X150
6941X185
6
10
16
25
35
50
70
95
120
150
185
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
285
355
435
585
685
835
1080
1375
1685
2120
2505
11.5
12.5
13.5
15.0
16.0
17.5
19.5
21.6
23.4
26.4
28.9
20/16
20/16
20S
20S
20
20
20
25
25
25
32
Temperature limits: -15 to +90°C.
*Bending radius:
4 x overall diameter.
Should not be installed at
temperatures below 0°C or above +60°C.
Core identification
Brown inner - Black outer.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
25
Low voltage PvC Fixed Wiring & Mains Cables
sPlit concentRic caBles PVc
Plain annealed stranded copper phase conductor, XLPE insulated surrounded by a concentric layer
of plain annealed solid copper neutral conductors. XLPE insulated and plain annealed solid strand
bare copper earth conductors, PVC outer sheath. Black. 600/1000 volts grade to BS 7870.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
4 SPLITCON
6 SPLITCON
10 SPLITCON
16 SPLITCON
25 SPLITCON
35 SPLITCON
4
6
10
16
25
35
7/0.85
7/1.04
7/1.35
7/1.70
**7/2.14
7/2.52
206
281
394
583
843
1300
9.6
11.4
12.7
14.6
18.7
23.0
20S
20
20
25
32
40
Temperature limits: -15 to +90°C.
**Stranding of neutral is the
same as phase conductor
except 25 sq mm which has 11 x 1.70mm.
Core identification: Brown Live/Blue Neutral.
Should not be installed at
temperatures below 0°C or above +60°C.
Also available in violet outer
sheath in 6mm, 10mm, 16mm & 25mm.
stRaiGHt concentRic caBles PVc
Plain annealed stranded copper phase conductor, PVC insulated surrounded by a concentric layer of
plain annealed solid copper neutral/earth conductors in concentric layer, PVC outer sheath. Black.
600/1000 volts grade to BS 7870 & ESI 09-7. Combined neutral and earth (CNE).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
4 STRCON
6 STRCON
16 STRCON
25 STRCON
35 STRCON
4
6
16
25
35
7/0.85
7/1.04
7/1.70
7/2.14
7/2.25
180
230
440
600
850
9.0
10.0
12.0
15.0
16.0
20S
20S
20
25
25
Temperature limits:
-15 to +70°C.
Core identification: Brown Live.
*Bending radius: 10 x overall
diameter.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
26
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
3300v Mains Cable
SECTION 2 3300v Mains Cables
3300v Mains Cables
sinGle coRe aRMouRed Mains caBles 1900/3300V PVc
Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, Aluminium wire armour,
PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2 )
Stranding
(mm)
6941AX120/3
6941AX150/3
6941AX185/3
6941AX240/3
6941AX300/3
6941AX400/3
6941AX500/3
6941AX630/3
120
150
185
240
300
400
500
630
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
No. Of Weight Overall Gland
Cores (Kg/Km) Diameter Size
(mm)
(mm)
1
1
1
1
1
1
1
1
1490
1870
2290
2880
3520
4520
5680
7120
23.2
26.3
28.7
31.4
34.1
38.9
42.8
47.3
25
32
32
40
40
50S
50S
50
Nylon
Cleat
Size
1.2
1.2
1.4
1.4
1.8
1.8
1.8
2.0
Trefoil
Cleat
376AC04
376AC05
376AC07
376AC10
376AC12
376AC15
Temperature limits:
-15 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
Brown inner/Black outer.
Should not be installed at
temperatures below 0°C or above +60°C.
sinGle coRe aRMouRed Mains caBle 1900/3300V lsZH
Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and
zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen
(LSZH) outer sheath. Black. 1900/3300 volts grade to BS6724. Acid gas emission to BS EN 50267
(IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1,
IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
Code
Conductor Stranding
Size
(mm)
(mm2 )
6941AB120/3
6941AB150/3
6941AB185/3
6941AB240/3
6941AB300/3
6941AB400/3
6941AB500/3
6941AB630/3
120
150
185
240
300
400
500
630
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
No. Of
Cores
1
1
1
1
1
1
1
1
Weight
Overall
(Kg/Km) Diameter
(mm)
1490
1870
2290
2880
3520
4520
5680
7120
23.2
26.3
28.7
31.4
34.1
38.9
42.8
47.3
Gland
Size
(mm)
25
32
32
40
40
50S
50S
50
Nylon Trefoil
Cleat Cleat
Size
1.2
1.2
1.4
1.4
1.8
1.8
1.8
2
376AC04
376AC05
376AC07
376AC10
376AC12
376AC15
Temperature limits:
-25 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
Brown inner/Black outer.
Should not be installed at
temperatures below 5°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
28
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
3300v Mains Cables
3 coRe Mains caBles 1900/3300V PVc
Stranded plain annealed copper conductors, XLPE insulated, PVC bedding, galvanised steel wire armour,
PVC outer sheath. Black. 1900/3300 volts grade to BS5467. Flame propagation to BS EN 60332.
CCC
Code
Conductor Stranding
Size
(mm)
(mm2)
XLPE3X16/3
XLPE3X25/3
XLPE3X35/3
XLPE3X50/3
XLPE3X70/3
XLPE3X95/3
XLPE3X120/3
XLPE3X150/3
XLPE3X185/3
XLPE3X240/3
XLPE3X300/3
XLPE3X400/3
16
25
35
50
70
95
120
150
185
240
300
400
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
No. Of
Cores
3
3
3
3
3
3
3
3
3
3
3
3
Weight
Overall
(Kg/Km) Diameter
(mm)
1600
2060
2330
3040
3800
4730
6070
7010
8270
10310
12300
14780
29.5
32.3
35.0
34.9
38.0
41.4
45.6
48.3
51.6
56.5
60.7
65.8
Gland
Size
(mm)
Nylon
Cleat
Size
32
32
40
40
40
50S
50S
50
50
63S
63
75S
1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
TC9
TC9
TC10
TC11
Temperature limits: -15 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
Brown, Black, Grey.
Should not be installed at
temperatures below 0°C or above +60°C.
3 coRe Mains caBles 1900/3300V lsZH
Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH)
extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath.
Black. 1900/3300 volts grade to BS6724. acid gas emission to BS EN 50267 (IEC 60754-1), smoke
emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN
50265, Categories C & a; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
LSF3X16/3
LSF3X25/3
LSF3X35/3
LSF3X50/3
LSF3X70/3
LSF3X95/3
LSF3X120/3
LSF3X150/3
LSF3X185/3
LSF3X240/3
LSF3X300/3
16
25
35
50
70
95
120
150
185
240
300
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
3
3
3
3
3
3
3
3
3
3
3
Weight
Overall
(Kg/Km) Diameter
(mm)
1600
2060
2330
3040
3800
4730
6070
7010
8270
10310
12300
29.5
32.3
35.0
34.9
38.0
41.4
45.6
48.3
51.6
56.5
60.7
Gland
Size
(mm)
Nylon
Cleat
Size
32
32
40
40
40
50S
50S
50
50
63S
63
1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
TC9
TC9
TC10
Temperature limits: -25 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
Brown, Black, Grey.
Should not be installed at
temperatures below 0°C or
above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
29
3300v Mains Cables
Mains caBles FoR Mines & QuaRRies 1900/3300V
Plain annealed stranded copper conductors, XLPE insulated, PVC extruded bedding, galvanised
steel wire armour incorporating tinned copper wires to provide 60% conductivity of any one phase,
PVC outer sheath. Black. 1900/3300 volts grade generally to BS5467 and BC295. Flame
propagation to BS EN 60332.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
NCB3X16/3
NCB3X25/3
NCB3X35/3
NCB3X50/3
NCB3X70/3
NCB3X95/3
NCB3X120/3
NCB3X150/3
NCB3X185/3
NCB3X240/3
NCB3X300/3
16
25
35
50
70
95
120
150
185
240
300
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
3
3
3
3
3
3
3
3
3
3
3
Weight
Overall
(Kg/Km) Diameter
(mm)
1600
2060
2330
3040
3800
4730
6070
7110
8270
10310
12300
29.5
32.3
35.0
34.9
38.0
41.4
45.6
48.3
51.6
56.5
60.7
Gland
Size
(mm)
Nylon
Cleat
Size
32
32
40
40
40
50S
50S
50
50
63S
63
1.2
1.4
1.4
1.4
1.6
1.8
1.8
2.0
TC9
TC9
TC10
Temperature limits:
-15 to +70°C.
*Bending radius:
up to 16mm2 - 6 x overall
diameter.
over 16mm2 - 8 x overall
diameter. Core identification: 3 core - Brown, Black, Grey.
Should not be installed at
temperatures below 0°C or above +60°C.
eeMua133 Mains caBles 1900/3300V PVc
Plain annealed stranded copper conductors, XLPE insulated, PVC bedding, lead sheathed, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. 1900/3300 volts grade to BS5467 and EEMUA
133 (formerly OCMA 4B). Flame propagation to BS EN 60332-1 (IEC 60332-1), bunched cables to BS
EN 50266-2-2 (IEC 60332-3-22 category A) and BS EN 50266-2-4 (IEC 60332-3-24 category C).
CCC
Code
EEMUA3X25/3
EEMUA3X35/3
EEMUA3X50/3
EEMUA3X70/3
EEMUA3X95/3
EEMUA3X120/3
EEMUA3X150/3
EEMUA3X185/3
EEMUA3X240/3
EEMUA3X300/3
Conductor
Size
(mm2)
25
35 50 70 95 120 150 185 240 300 Stranding No. Of
(mm)
Cores
7/2.14 19/1.53 19/1.78 19/2.14 19/2.52 37/2.03 37/2.25 37/2.52 61/2.25 61/2.52 Weight
Overall
(Kg/Km) Diameter
(mm)
3 3400 32.5
3 3560 38.4 3 4520 38.1 3 5550 41.4 3 6770 45.0 3 8390 49.4 3 9630 52.3 3 11270 55.8 3 13720 60.9 3 16380 65.3 Gland
Size
(mm)
Nylon
Cleat
Size
32
40
40
50S
50S
50
50
63S
63
75S
1.4
1.6
1.6
1.8
2.0
2.0
TC9
TC9
TC10
TC11
Temperature limits:
-15 to +90°C.
*Bending radius:
12 x overall diameter.
Core identification:
Brown, Black, Grey.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
30
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
LSZH Fixed Wiring & Mains Cables
SECTION 3 LSZH Fixed Wiring & Mains Cables
LSZH Fixed Wiring & Mains Cables
6491B (Ho7Z-R) lsZH
Stranded plain annealed compacted circular copper conductor, low smoke and zero halogen (LSZH)
outer sheath. 450/750 volts grade to BS7211. Acid gas emission to BS EN 50267 (IEC60754), smoke
emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332), low
smoke and zero halogen (LSZH).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Brass A2
Nylon A2
6491B1/5
6491B2/5
6491B4
6491B6
6491B10
6491B16
6491B25
6491B35
6491B50
6491B70
6491B95
6491B120
6491B150
6491B185
6491B240
6491B300
6491B400
6491B500
6491B630
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
7/2.52
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.50
22
33
49
69
116
175
273
367
510
715
990
1230
1510
1900
2490
3050
3842
4900
6334
3
3.65
4.2
4.75
6.15
7.1
8.9
9.95
11.7
13.35
15.6
17.2
19.1
21.3
24.36
27.05
30.35
32.8
36.5
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
20
25
25
25
32
32
40
40
50S
50S
16
16
16
16
16
16
20
20
20
25
25
25
32
32
32
40
40
50
50
Temperature limits: -15 to +90°C.
*Bending radius:
up to 10mm2 - 3 x overall
10 to 25mm2 - 4 x overall
diameter.
Above 25mm2 - 6 x overall
diameter.
Standard colours available: 1.5mm2 & 2.5mm2 - Brown,
Black, Grey, Blue,
Green/Yellow, White, Orange,
Turquoise, violet, Pink.
4mm2 - 630mm2 - Brown,
Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0°C or above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
32
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
LSZH Fixed Wiring & Mains Cables
suRFace WiRinG caBles lsZH 6181B
Plain annealed stranded circular copper conductor, single core, XLPE insulated, (LSZH) sheathed,
Ref 6181B. 300/500 volts grade to BS7211. Brown/White or Grey/White. Acid gas emission to BS EN
50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN
50265 (IEC 60332), low smoke and zero halogen (LSZH).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6181B1
6181B1/5
6181B2/5
6181B4
6181B6
6181B10
6181B16
6181B25
6181B35
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
1/1.13
1/1.38
1/1.78
7/0.85
7/1.04
7/1.35
7/1.04
7/2.14
7/2.52
1
1
1
1
1
1
1
1
1
Weight
Overall
(Kg/Km) Diameter
(mm)
28
34
49
75
99
155
225
340
440
4.5
5.1
6.0
6.8
7.4
8.8
10.5
12.5
13.5
Gland
Ref
Nylon
Size
Size
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
- 0.5
0.5
0.6
Temperature limits:
-25 to +90°C.
*Bending radius:
up to 10mm2 - 3 x overall
diameter.
over 10mm2 - 4 x overall
diameter.
Should not be installed at
temperatures below 0°C or above +40°C.
suRFace WiRinG caBles lsZH 624*B
Plain annealed compacted copper conductor, XLPE insulated, one, two or three cores laid flat with
an uninsulated circuit protective conductor and (LSZH) sheathed. White. Ref 6241/2/3B 300/500V
to BS7211 low smoke and zero halogen (LSZH). Acid gas emission to BS EN 50267 (IEC60754),
smoke emission to BS EN 50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332),
low smoke and zero halogen (LSZH).
CCC
Code
Conductor
Size
(mm2)
6241B1/5BR 6241B1/5BR
6242B1WH
6242B1/5WH
6242B1/5BRBR
6242B2/5WH
6242B4WH
6242B6WH
6242B10WH
6242B16WH
6243B1WH
6243B1/5WH
6243B2/5WH
1.5
1.5
1.0
1.5
1.5
2.5
4.0
6.0
10.0
16.0
1.0
1.5
2.5
Stranding
(mm)
No.Of
Cores
CPC Size
(mm2)
Weight
(Kg/Km)
Overall
Diameter
(mm)
1/1.37
1/1.37
1/1.13
1/1.37
1/1.37
1/1.77
7/0.85
7/1.04
7/1.35
7/1.70
1/1.13
1/1.37
1/1.77
1
1
2
2
2
2
2
2
2
2
3
3
3
1.0
1.0
1.0
1.0
1.0
1.5
1.5
2.5
4.0
6.0
1.0
1.0
1.5
51
51
69
85
85
120
175
240
390
560
92
115
170
4.65 X 5.80
4.65 X 5.80
4.10 X 8.65
4.55 X 8.80
4.55 X 8.80
5.40 X 10.50
6.10 X 12.00
6.90 X 13.80
8.40 X 18.50
9.70 X 20.60
4.60 X 10.20
5.75 X 11.45
5.30 X 12.80
Temperature limits:
-25 to +90°C.
*Bending radius:
Fixed = 3 x diameter
Should not be installed at
temperatures below 0°C or above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
33
LSZH Fixed Wiring & Mains Cables
Mains and contRol caBles lsZH
Plain annealed stranded copper conductors, XLPE insulated, low smoke and zero halogen
(LSZH) bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer
sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 607541), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC
60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
Code
LSF2X1/5
LSF3X1/5
LSF4X1/5
LSF5X1/5
LSF7X1/5
LSF12X1/5
LSF19X1/5
LSF27X1/5
LSF37X1/5
LSF48X1/5
LSF2X2/5
LSF3X2/5
LSF4X2/5
LSF5X2/5
LSF7X2/5
LSF12X2/5
LSF19X2/5
LSF27X2/5
LSF37X2/5
LSF48X2/5
LSF2X4
LSF3X4
LSF4X4
LSF5X4
LSF7X4
LSF12X4
LSF19X4 LSF27X4
LSF2X6
LSF3X6
LSF4X6
LSF5X6
LSF7X6
LSF2X10
LSF3X10
LSF4X10
LSF5X10
LSF7X10
LSF2X16
LSF3X16
LSF4X16
LSF5X16
LSF7X16
Conductor
Size
(mm2)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0 4.0
6.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
10.0
10.0
16.0
16.0
16.0
16.0
16.0
Stranding
(mm)
No. Of
Cores
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
7/1.70
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
19
27
37
48
2
3
4
5
7
12
19
27
2
3
4
5
7
2
3
4
5
7
2
3
4
5
7
Weight
Overall
(Kg/Km) Diameter
(mm)
260
295
350
362
398
680
885
1310
1590
1958
270
360
410
435
520
905
1360
1760
2185
3003
381
435
495
583
760
1266
1701
2347
405
490
670
823
1100
600
750
885
1106
1500
905
990
1195
1695
2150
11
11.2
12.5
12.9
13.7
18
20.6
25.1
27.5
31
12.2
12.8
13.5
14.7
15.6
21
25
30
33
37.3
13.1
13.7
14.8
16.35
18.2
24.24
27.61 32.3
14.1
14.8
17.3
18.39
21.9
16.1
17.9
19.3
20.91
25
19
20
22
25.19
28.1
Gland
Size
(mm)
20/16
20/16
20S
20S
20S
20
25
32
32
32
20S
20S
20S
20
20
25
32
32
40
40
20S
20S
20
20
20
25
32 40
20
20
20
20
25
20
20
25
25
25
25
25
25
25
32
Nylon
Cleat
Size
0.5
0.5
0.5
0.6
0.6
0.8
0.9
1.0
1.1
1.4
0.5
0.6
0.6
0.6
0.7
0.9
1.0
1.2
1.4
1.6
0.6
0.6
0.6
0.7
0.8
1.0
1.2
1.4
0.6
0.6
0.7
0.8
0.9
0.7
0.8
0.8
0.9
1.0
0.8
0.8
0.9
1.0
1.2
Temperature limits:
-25 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
5 core and above - Up to 6mm2 White with Black numbers.
5 - 10mm2 and 16mm2 - Brown,
Black, Grey, Blue, Green/Yellow.
1.5 & 2.5 - 2,3,4 core also available in white numbered
cores to ESI 09-6.
Should not be installed at
temperatures below 0°C or above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
34
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
LSZH Fixed Wiring & Mains Cables
Mains caBles lsZH
Stranded plain annealed copper conductors, XLPE insulated, low smoke and zero halogen (LSZH)
extruded bedding, galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath.
Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267 (IEC 60754-1), smoke
emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1, IEC 60332-3, BS EN
50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
Code
LSF2X25
LSF3X25
LSF4X25
LSF5X25
LSF2X35
LSF3X35
LSF4X35
LSF5X35
LSF2X50
LSF3X50
LSF4X50
LSF5X50
LSF2X70
LSF3X70
LSF4X70
LSF5X70
LSF2X95
LSF3X95
LSF4X95
LSF5X95
LSF2X120
LSF3X120
LSF4X120
LSF5X120
LSF2X150
LSF3X150
LSF4X150
LSF5X150
LSF2X185
LSF3X185
LSF4X185
LSF5X185
LSF2X240
LSF3X240
LSF4X240
LSF2X300
LSF3X300
LSF4X300
LSF3X400
LSF4X400
Conductor
Size
(mm2)
25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
120
150
150
150
150
185
185
185
185 240
240
240
300
300
300
400
400
Stranding
(mm)
7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
37/2.52 61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
No. Of
Cores
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5 2
3
4
2
3
4
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
1050
1500
1800
2200
1400
1800
2200
2800
1750
2250
2850
3850
2200
3000
4100
5100
3000
4150
5200
7700
3600
4950
6700
9030
4250
6300
7900
10752
5500
7650
9650
11765 6900
9650
12400
8200
11550
14800
14350
19300
20
23
25
29
22
26
28
33
25
28
31
38
28
32
37
43
32
37
40
52
35
40
46
56.7
37
45
49
64.31
43
49
55
64.6 48
56
62
50
59
66
65
75
Gland
Size
(mm)
25
25
32
32
25
32
32
40
32
32
32
40
32
32
40
50S
32
40
50S
50
40
50S
50
63S
40
50S
50
63
50S
50
63S
75S 50
63S
63
50
63
75S
75S
75
Nylon
Cleat
Size
0.8
1.0
1.0
1.2
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.6
1.2
1.4
1.6
1.8
1.4
1.6
1.6
TC9
1.4
1.6
2.0
TC9
1.6
1.8
2.0
TC11
1.8
2.0
TC9
TC11
2.0
TC9
TC10
2.0
TC10
TC11
TC11
TC12
Temperature limits:
-25 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
5 core - Brown, Black, Grey,
Blue, Green/Yellow.
Should not be installed at temperatures below 0°C or above +40°C.
nB 5 coRe 95MM
and aBoVe aRe
ManuFactuRed
to iec60502-1
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
35
LSZH Fixed Wiring & Mains Cables
sinGle coRe non-aRMouRed Mains caBles lsZH
Plain annealed stranded compacted circular copper conductor, single core, XLPE insulated, low
smoke and zero halogen (LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas
emission to BS EN 50267 (IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame
propagation to IEC 60332-1, IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low
smoke and zero halogen (LSZH).
CCC
Code
Conductor
Size
(mm2)
6181B50
6181B70
6181B95
6181B120
6181B150
6181B185
6181B240
6181B300
6181B400
6181B500
6181B630
6181B800
6181B1000
50
70
95
120
150
185
240
300
400
500
630
800
1000
Stranding Weight
Overall Brass
(mm)
(Kg/Km) Diameter
A2
(mm)
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.52
61/3.20
127/2.52
127/2.85
127/3.20
525
730
990
1230
1525
1885
2440
3045
3855
4950
6345
8140
9860
13
15.5
18
19.5
21.5
24
27
29.5
33
37.5
42
47.5
53
25
25
25
32
32
32
40
40
50S
50S
50
63S
63
Nylon
A2
Nylon
Cleat
Size
Trefoil
Cleat
25
25
25
32
32
32
40
40
50
50
63
-
0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.6
1.8
2.0
TC9
376AC04
376AC06
376AC09
376AC12
376AC15
376AC19
Temperature limits:
-25 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
Brown inner/Black outer.
Should not be installed at
temperatures below 0°C or above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
36
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
LSZH Fixed Wiring & Mains Cables
sinGle coRe aRMouRed Mains caBles lsZH
Stranded plain annealed compacted circular copper conductors, XLPE insulated, low smoke and
zero halogen (LSZH) extruded bedding, aluminium wire armour, low smoke and zero halogen
(LSZH) outer sheath. Black. 600/1000 volts grade to BS6724. Acid gas emission to BS EN 50267
(IEC 60754-1), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to IEC 60332-1,
IEC 60332-3, BS EN 50265, Categories C & A; BS EN 50266,low smoke and zero halogen (LSZH).
CCC
Code
Conductor Stranding No. Of Weight Overall
Gland
Gland Nylon
Size
(mm)
Cores (Kg/Km) Diameter Size Cw Size
Cleat
(mm)
Ali
Brass A2 Size
(mm2)
(mm)
(mm)
6941AB50
50.0
6941AB70
70.0
6941AB95
95.0
6941AB120 120.0
6941AB150 150.0
6941AB185 185.0
6941AB240 240.0
6941AB300 300.0
6941AB400 400.0
6941AB500 500.0
6941AB630 630.0
6941AB800 800.0
6941AB1000 1000.0
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.2
127/2.52
127/2.85
127/3.2
1
1
1
1
1
1
1
1
1
1
1
1
1
638
891
1166
1412
1800
2200
2800
3400
4450
5550
7100
9200
11270
17.70
19.60
21.50
23.10
26.00
28.00
32.00
33.00
38.00
43.00
47.00
55.00
58.80
20
25
25
25
32
32
40
40
40
50S
50
63S
63S
25
32
32
32
40
40
50S
50S
50
63S
63S
75S
75S
Trefoil
Cleat
0.7
0.8
0.9
1.0
1.1
1.2 376AC04
1.4 376AC06
1.4 376AC06
1.6 376AC10
1.8 376AC13
2.0 376AC15
TC9 376AC20
TC10 376AC22
Temperature limits:
- 25 to + 90°C.
*Bending radius:
6 x Overall Diameter.
Core identification:
Brown inner - Black outer.
Should not be installed at
temperatures below 0°C or
above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
37
LSZH Fixed Wiring & Mains Cables
scReened FiXed WiRinG and Mains caBles to Bs 8436
Plain annealed stranded copper, XLPE insulated, tinned annealed stranded copper earth wire,
bonded aluminium tube applied longitudinally, low smoke and zero halogen (LSZH) outer sheath, to
BS EN 50267-1:1998 and BS EN 50268-2:2000, UV Stable. 600/1000v to BS8436, White. Acid gas
emissions to BS EN 50267-2-1, smoke emissions to BS EN 50268-2 and flame retardant to BS EN
60332-1-2 (IEC 60332-1-1).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
CSX2X1WH
CSX3X1WH
CSX4X1WH
CSX2X1/5WH
CSX3X1/5WH
CSX4X1/5WH
CSX2X2/5WH
CSX3X2/5WH
CSX4X2/5WH
CSX2X4WH
CSX3X4WH
CSX4X4WH
CSX2X6WH
CSX3X6WH
CSX4X6WH
CSX2X10WH
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
4
4
4
6
6
6
10
7/0.44
7/0.44
7/0.44
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
Weight
Overall
(Kg/Km) Diameter
(mm)
85
105
130
106
140
158
135
182
259
206
265
320
258
328
450
413
8.60
9.40
10.00
9.80
10.40
11.30
10.80
11.10
12.60
11.50
13.10
13.90
13.10
14.20
14.90
16.1
1 Hole
Clip
Ref
Gland
Ref
RCHL34
RCHL37
RCHL37
RCHL37
RCHL40
RCHL43
RCHL43
RCHL43
RCHL47
RCHL43
RCHL51
RCHL54
RCHL51
RCHL54
RCHL59
RCHL63
20SA2
20SA2
20A2
20A2
20A2
20A2
20A2
20A2
20A2
20A2
25A2
25A2
25A2
25A2
25A2
25A2
Minimum installation
temperature: -10°C.
Maximum continuous
conductors operating
temperature: +90°C.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
Solid cores available on
request. Different sheath and
core colours available on
request.
10mm2 and 16mm2 available on request.
Also available in 300/500
volt rating.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
38
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Medium voltage 11000v & Above
SECTION 4 Medium voltage 11000v & Above
Medium voltage 11000v & Above
sinGle coRe aRMouRed Mains caBles PVc 11000V
Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting
tape insulated, copper tape screen, PVC bedding, aluminium wire armour, PVC outer sheath - Red.
6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red outer
sheath can be prone to fading when exposed to U.V rays.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
Size
Nylon
Cleat
Size
Trefoil
Cleat
10001
10002
10003
10004
10005
10006
10007
10008
10009
10010
1 001 1
50
70
95
120
150
185
240
300
400
500
630
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
127/2.52
1
1
1
1
1
1
1
1
1
1
1
1200
1461
1761
2049
2451
2848
3470
4103
4995
6320
7840
28.7
30.5
32.2
33.8
36.2
37.9
40.4
42.6
45.6
50
54
12
14
14
14
16
16
16
18
18
20
TC9
376AC04 376AC05
376AC06
376AC07
376AC08
376AC09
376AC11
376AC12
376AC14
376AC17
376AC19
Temperature limits:
up to 90°C.
*Bending radius:
12 x overall diameter.
Core identification:
Brown.
Should not be installed at
temperatures below 0°C or above +60°C.
3 coRe Mains caBles PVc 11000V
Stranded plain annealed circular compacted copper conductors, XLPE insulated, semi-conducting
tape insulated, each core copper tape screened, PVC bedding, galvanised steel wire armour, PVC
outer sheath - Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN
60332. Red outer sheath can be prone to fading when exposed to U.V rays.
CCC
Code
11Kv XLPE3X25RD
11Kv XLPE3X35RD
11Kv XLPE3X50RD
11Kv XLPE3X70RD
11Kv XLPE3X95RD
11Kv XLPE3X120RD
11Kv XLPE3X150RD
11Kv XLPE3X185RD
11Kv XLPE3X240RD
11Kv XLPE3X300RD
11Kv XLPE3X400RD
Conductor Stranding
Size
(mm)
(mm2)
25
35
50
70
95
120
150
185
240
300
400
7/2/14
19/1/53
19/1/78
19/2/14
19/2/52
37/2/03
37/2/25
37/2/52
61/2/25
61/2/52
61/2/85
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
3
3
3
3
3
3
3
3
3
3
3
4300
4491
5105
6019
7148
8199
9274
10706
13740
16051
19095
48.4
50.5
53.3
56.9
61
64.6
67.8
71.9
78.8
84.1
90.3
2.0
2.0
TC9
TC9
TC10
TC11
TC11
TC12
TC14
TC14
TC15
Temperature limits:
up to 90°C.
*Bending radius:
12 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
40
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Medium voltage 11000v & Above
3 coRe Mains caBles PVc 11000V
Plain stranded aluminium conductors, XLPE insulated, semi-conducting tape insulated, each core
copper tape screened, PVC bedding (extruded), galvanised steel wire armour, PVC outer sheath.
Red. 6350/11000 volts grade to BS6622 and IEC 60502. Flame propagation to BS EN 60332. Red
outer sheath can be prone to fading when exposed to U.V rays.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
10115RD
10116RD
10117RD
10118RD
10119RD
10120RD
95
120
150
185
240
300
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
3
3
3
3
3
3
5800
6400
7000
7800
9800
11000
62.6
66.6
68.6
74.1
81.2
86.8
TC10
TC11
TC11
TC12
TC14
TC15
Temperature limits:
up to 90°C.
*Bending radius:
13 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0°C or above +60°C.
tRiPleX caBles 11000V
Solid or stranded aluminium conductor, XLPE insulated, copper wire screen (35mm2). MDPE outer
sheath. Red. 6350/11000 volts grade to BS7870. Red outer sheath can be prone to fading when
exposed to U.V rays.
CCC
Code
Conductor
Size
(mm2)
11KvTRIP3X70AL 70
11KvTRIP3X70AL 70
11KvTRIP3X95AL
95
11KvTRIP3X95AL
95
11KvTRIP3X185AL 185
11KvTRIP3X185AL 185
11KvTRIP3X300AL 300
11KvTRIP3X300AL 300
Conductor
Type
Nominal
Conductor
Diameter (mm)
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
SOLID
STRANDED
9.30
9.80
10.70
12.16
14.90
15.80
19.00
20.50
No. Of
Cores
Weight
(Kg/Km)
Diameter
In Triplex
Formation
3
3
3
3
3
3
3
3
2763
2650
3055
2901
4095
4060
5374
5360
57.4
58.3
60.8
57.83
70.5
72.5
80.4
81.4
Temperature limits:
-15 to +90°C.
*Bending radius:
15 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
41
Medium voltage 11000v & Above
PaPeR insulated Mains caBles PVc 11000V
COPPER CONDUCTOR
Plain annealed copper conductors, paper insulated, paper belted, semi-conducting carbon paper
tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer
sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332. Red
outer sheath can be prone to fading when exposed to U.V rays.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
PILC3X25RD
PILC3X35RD
PILC3X50RD
PILC3X70RD
PILC3X95RD
PILC3X120RD
PILC3X150RD
PILC3X185RD
PILC3X240RD
PILC3X300RD
PILC3X400RD
25
35
50
70
95
120
150
185
240
300
400
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
3
3
3
3
3
3
3
3
3
3
3
5230
5890
6620
7820
9240
10400
11770
13550
16390
19870
23700
43.6
42.3
45.6
49.7
53.3
56.2
59.2
62.8
67.8
73.6
79.4
1.8
2.0
2.0
2.0
TC9
TC9
TC10
TC10
TC11
TC12
TC14
Temperature limits:
up to 65°C.
*Bending radius:
13 x overall diameter.
Core identification:
White printed numbers on insulating papers.
Should not be installed at
temperatures below 0°C or above +60°C.
ALUMINIUM CONDUCTOR
Plain aluminium stranded conductors, paper insulated, paper belted, semi-conducting carbon paper
tape bedding, lead sheathed, textile compound bedding, galvanised steel wire armour, PVC outer
sheath - Red. 6350/11000 volts grade to BS6480/88. Flame propagation to BS EN 60332.
Red outer sheath can be prone to fading when exposed to U.V rays.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
10100RD
10103RD
10105RD
95
185
300
19/2.52
37/2.52
61/2.52
3
3
3
7115
9521
13403
53.2
63.5
71.5
TC9
TC11
TC12
Temperature limits: up to 65°C.
*Bending radius: 13 x overall diameter.
Core identification: White printed
numbers on insulating papers.
Should not be installed at
temperatures below 0°C or above +60°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
42
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Medium voltage 11000v & Above
sinGle coRe aRMouRed Mains caBles lsZH 11000V
Stranded plain annealed compacted circular copper conductor, XLPE insulated, semi-conducting
tape insulated, copper tape screen, low smoke and zero halogen (LSZH) bedding, aluminium wire
armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000 volts grade to
BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC
61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor U.V
resistant qualities, red outer sheath cables are not recommended for outdoor installation.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
Trefoil
Cleat
10050
10051
10052
10053
10054
10055
10056
10057
10058
10059
10060
50
70
95
120
150
185
240
300
400
500
630
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61X3.20
127X2.52
1
1
1
1
1
1
1
1
1
1
1
1200
1461
1761
2049
2451
2848
3470
4103
4995
6320
7840
28.7
30.5
32.2
33.8
36.2
37.9
40.4
42.6
45.6
50
54
12
14
14
14
16
16
16
18
18
20
TC9
376AC04
376AC05
376AC06
376AC07
376AC08
376AC09
376AC1 1
376AC12
376AC14
376AC17
376AC19
Temperature limits:
up to 90°C.
*Bending radius:
15 x overall diameter.
Core identification: Brown.
Should not be installed at
temperatures below 0°C or above +40°C.
3 coRe Mains caBles lsZH 11000V
Stranded plain annealed compacted circular copper conductors, XLPE insulated, semi-conducting
tape insulated, each core copper tape screened, low smoke and zero halogen (LSZH) bedding,
galvanised steel wire armour, low smoke and zero halogen (LSZH) outer sheath - Red. 6350/11000
volts grade to BS7835. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN
50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332). Due to poor
U.V resistant qualities red outer sheath cables are not recommended for outdoor installation.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Nylon
Cleat
Size
10302RD
10304RD
10306RD
10308RD
10310RD
10312RD
10314RD
10316RD
10318RD
10320RD
35
50
70
95
120
150
185
240
300
400
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
70/3.15
3
3
3
3
3
3
3
3
3
3
4501
5117
6032
7163
8216
9292
10726
13763
16077
19124
50.5
53.3
56.9
61
64.6
67.8
71.9
78.8
84.1
90.3
TC9
TC9
TC9
TC10
TC11
TC11
TC12
TC14
TC14
TC15
Temperature limits:
- 15 to + 70°C
*Bending radius:
12 x overall diameter.
Should not be installed at
temperatures below 0°C or above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
43
Medium voltage 11000v & Above
tHRee coRe Mains caBles 22KV and 33KV
Compacted circular stranded annealed copper conductor, extruded semi-conductive conductor
screen, XLPE insulated, extruded strippable semi-conductive insulation screen helically overlapped
copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel
wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 12700/22000 volts grade to
BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for
outdoor installation.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
22KvXLPE3X95RD
95.0
19/2.52
3
8820
70.30
Temperature limits: - 15 to + 90°C.
*Bending radius:
12 x overall diameter.
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0°C or
above +40°C.
Compacted circular stranded annealed copper conductor, extruded semi-conductive conductor
screen, XLPE insulated, extruded strippable semi-conductive insulation screen helically overlapped
copper tape metallic screen, extruded low smoke zero halogen(LSZH) bedding, galvanised steel
wire armour, extruded low smoke zero halogen (LSZH) sheath - Red. 19000/33000 volts grade to
BS7835. Due to poor U.V resistant qualities red outer sheath cables are not recommended for
outdoor installation.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
33KvLSF3X95RD
33KvLSF3X185RD
95.0
185.0
19/2.52
37/2.52
3
3
12020
20000
85.30
96.00
Temperature limits:
- 15 to + 90°C.
*Bending radius:
12 x overall diameter
Core identification:
Brown, Black, Grey tapes.
Should not be installed at
temperatures below 0°C or
above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
44
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
High voltage 33000v Service And Windfarm Cables
SECTION 5 High voltage 33000v Service And Windfarm Cables
High voltage 33000v Service And Windfarm Cables
sinGle coRe Mains caBle MdPe 33000V WindFaRM caBle
Round stranded compacted aluminium conductor, inner semi-conductive layer XLPE insulated,
outer semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape
metallic screen (35mm2), polyester tape/water blocking swelling tape separator, extruded black
MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
33Kv1X70AL
33Kv1X95AL
33Kv1X120AL
33Kv1X150AL
33Kv1X185AL
33Kv1X240AL
33Kv1X300AL
33Kv1X400AL
33Kv1X500AL
33Kv1X630AL
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
1 9/2 .1
19/2.47
35/2.04
35/2.27
35/2.54
35/2.91
35/3.25
56/2.91
56/3.3
56/3.75
1
1
1
1
1
1
1
1
1
1
1339
1467
1584
1720
1881
2130
2381
2723
3146
3675
36.70
38.40
39.80
41.30
43.00
45.50
47.80
50.80
54.30
58.90
Rated voltage Uo/U 19/33 kv
Max operating voltage 36 kv
Test voltage 75 kv
Partial discharge level with voltage 2Uo kv max. 5pC
Max. perm conductor temperature 90°C
Max. perm operating temperature 130°C
Short circuit temperature 250°C
*Minimum bending radius 12 x overall diameter
sinGle coRe Mains caBle MdPe 33000V seRVice caBle
Round stranded compacted copper conductor, inner semi-conductive layer XLPE insulated, outer
semi-conductive layer, semi-conductive swelling tape insulation screen, copper wire and tape
metallic screen (35mm2), polyester tape/water blocking swelling tape separator, extruded black
MDPE outer sheath. 33000 volts grade to BS7870, IEC 60502-2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
33KvCU1X70BK
33KvCU1X95BK
33KvCU1X120BK
33KvCU1X150BK
33KvCU1X185BK
33KvCU1X240BK
33KvCU1X300BK
33KvCU1X400BK
33KvCU1X500BK
33KvCU1X630BK
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
500.0
630.0
1 9/2.1 1
19/2.48
35/2.05
35/2.28
35/2.55
35/2.92
35/3.28
56/2.93
56/3.32
56/3.77
1
1
1
1
1
1
1
1
1
1
1751
2043
2309
2614
2997
3596
4225
5069
6156
7570
36.50
38.20
39.60
41.20
42.90
45.40
47.80
50.60
53.90
57.60
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
46
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Fire Protection, Alarm & Security Cables
SECTION 6 Fire Protection, Alarm & Security Cables
Fire Protection, Alarm & Security Cables
FiRePRooF caBles - MineRal insulated
Solid plain annealed copper conductors, magnesium oxide insulated, solid copper sheath to BS6207, IEC
331 and BS 6387 CWZ. Available in the following options:
(a)Light Duty = 500 volts grade
Heavy Duty = 1000 volts grade
(b)Outer sheath finishes, bare copper,
PVC or LSZH
(c)Outer sheath colours. Orange, Red,
White or Black.
Size
Ref.
Bare
(Kg/Km)
Sheathed
(Kg/Km)
Overall
Diameter
Bare
(mm)
Overall
Diameter
Sheathed
(mm)
Gland
For Use
With Rps
Seals
2L1.0
2L1.5
2L2.5
2L4.0
3L1.0
3L1.5
3L2.5
4L1.0
4L1.5
4L2.5
7L1.5
7L2.5
1H6.0
1H10
1H16
1H25
1H35
1H50
1H70
1H95
1H120
1H150
1H240
2H1.5
2H2.5
2H4.0
2H6.0
2H10
2H16
2H25
3H1.5
3H2.5
3H4.0
3H6.0
3H10
3H16
3H25
4H1.5
4H2.5
4H4.0
4H6.0
4H10
4H16
4H25
7H1.5
7H2.5
12H2.5
19H1.5
104.0
136.0
187.0
248.0
136.0
176.0
223.0
162.0
203.0
277.0
295.0
411.0
173.0
240
326
457
585
758
1016
1324
1612
1949
3050
237
276
355
446
619
850
1178
254
323
415
526
754
1034
1444
305
384
507
644
911
1286
1805
432
559
911
992
125.00
159.00
213.00
282.00
159.00
201.00
256.00
187.00
230.00
313
332
454
213
273
361
499
632
810
1075
1413
1709
2055
3213
272
314
397
493
673
912
1277
290
364
460
575
812
1124
1549.00
345.00
428.00
556.00
698.00
974.00
1386.00
1947.00
479.00
611.00
1001.00
1088.00
5.1
5.7
6.6
7.7
5.8
6.4
7.3
6.3
7
8.1
8.4
9.7
6.4
7.3
8.3
9.6
10.7
12.1
13.7
15.4
16.8
18.4
23.3
7.9
8.7
9.8
10.9
12.7
14.7
17.1
8.3
9.3
10.4
11.5
13.6
15.6
18.2
9.1
10.1
11.4
12.7
14.8
17.3
20.1
10.8
12.1
15.6
16.6
6.6
7.2
8.1
9.4
7.3
7.9
9
7.8
8.5
9.8
10.1
11.4
7.7
9
10
11.3
12.4
13.8
15.4
17.7
19.1
20.7
26.1
9.6
10.4
11.5
12.6
14.4
16.4
19.4
10
11
12.1
13.2
15.3
17.9
20.5
10.8
11.8
13..1
14.4
16.5
19.6
22.9
12.5
13.8
17.9
18.9
20
20
20
20
20
20
20
20
20
20
25
25
20
20
20
20
20
25
25
25
32
32
40
20
20
20
20
25
25
32
20
20
20
25
25
25
40
20
20
25
25
25
32
40
25
25
32
40
Single Hole Clip
Reference
Bare
Sheathed
20
22
26
30
22
24
28
24
28
32
32
37
34
28
32
37
40
47
54
59
63
71
88
30
34
37
43
47
54
67
32
37
40
43
54
59
71
37
40
43
47
54
67
79
43
47
59
63
26
28
32
37
28
30
34
30
34
37
40
43
34
34
37
43
47
54
59
67
75
79
101
37
40
43
47
54
63
75
37
43
47
51
59
71
79
43
47
51
54
63
75
88
47
54
71
71
Nominal
Std Drum
Lths (Mts)
500
500
500
500
500
500
500
500
500
500
380
285
650
510
400
275
222
170
190
155
135
110
67
500
500
500
500
500
112
80
500
500
500
184
130
100
70
500
500
195
144
110
89
60
245
195
148
112
Temperature limits:
PvC sheath -20 to +70°C.
LSF sheath -20 to +80°C.
*Bending radius:
6 x overall diameter.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
48
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Fire Protection, Alarm & Security Cables
standaRd FiRe alaRM and secuRitY WiRinG caBles
Plain annealed copper conductor, silicon rubber insulated aluminium/polyester tape screen, tinned
annealed copper earth wire, low smoke zero halogen (LSZH) outer sheath. Red, White, Orange or
Black. Fire resistant to IEC 331 and BS6387. Flame retardant to BS5839-1:2003 and IEC 60332-3 CAT
CWZ, BS7629-1 1997. Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN
50268 (IEC 61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
FP2X1
FP3X1
FP4X1
FP7X1
FP12X1
FP2X1/ 5
FP3X1/ 5
FP4X1/5
FP7X1/5
FP12X1/5
FP19X1/5
FP2X2/5
FP3X2/5
FP4X2/5
FP7X2/5
FP12X2/5
FP19X2/5
FP2X4
FP3X4
FP4X4
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.78
1/1.78
1/1.78
1/1.78
1/1.78
1/1.78
7/0.85
7/0.85
7/0.85
2+E
3+E
4+E
7+E
12+E
2+E
3+E
4+E
7+D
12+D
19+D
2+E
3+E
4+E
7+D
12+D
19+D
2+E
3+E
4+E
Weight
Overall Gland
(Kg/Km) Diameter Size
(mm)
(mm)
90
110
135
170
270
110
130
160
230
365
540
160
200
250
285
470
720
260
315
380
7.5
8.0
8.8
10.5
13.7
8.0
8.4
9.5
11.3
15.2
17.8
9.0
10.5
11.7
13.7
17.9
21.4
11.3
12.1
13.3
20
20
20
20
25
20
20
20
20
25
25
20
20
20
20
25
32
20
25
25
1 Hole
Clip Ref
Gland
Ref
28
30
34
40
54
32
34
37
43
59
67
34
40
43
54
67
79
43
47
54
251
251
251
252
254
251
251
251
252
254
254
252
252
252
252
254
255
252
254
254
E = Bare earth conductor.
D = Drain wire.
Temperature limits:
-10 to +80°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
7 core and above - White
with Black numbers.
Should not be installed at
temperatures below 0°C or
above +40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
49
Fire Protection, Alarm & Security Cables
enHanced FiRe alaRM and secuRitY WiRinG caBles
Plain annealed copper conductor, enhanced silicon rubber insulated, enhanced aluminium/polyester
tape screen, tinned annealed copper earth wire, enhanced low smoke zero halogen outer sheath.
Red or white. Manufactured to meet the Enhanced standard of BS5839-1 2002 +A2:2008 Clause
26.2e Enhanced and also the requirements of BS8434 - 2:2003 120 minutes and BS EN 50200 Class
PH120. Fire resistant to BS7629-1:2008, BS6387:1994 clause 11 CWZ, halogen emissions to BS EN
50267-2-1:1999 and low smoke standard BS EN 61034-2:2005.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
ENH2X1/5
ENH3X1/5
ENH4X1/5
ENH2X2/5
ENH3X2/5
ENH4X2/5
ENH2x4
ENH3x4
ENH4x4
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
4.0
1/1.38
1/1.38
1/1.38
1/1.78
1/1.78
1/1.78
7/0.85
7/0.85
7/0.85
2+E
3+E
4+E
2+E
3+E
4+E
2+E
3+E
4+E
Weight
Overall Gland 1 Hole
(Kg/Km) Diameter Size Clip Ref
(mm)
(mm)
110
130
160
160
200
250
260
315
380
8.0
8.4
9.5
9.0
10.5
11.7
11.3
12.1
13.3
20
20
20
20
20
20
20
25
25
32
34
37
34
40
43
43
47
51
Gland
Ref
251
251
251
252
252
252
252
254
254
E = Bare earth conductor.
Temperature limits:
-40 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
Should not be installed at
temperatures below 0°C or
above +40°C.
FiRePRooF caBles - sinGles
Plain annealed copper conductor, mica fire resistant tape, low smoke zero halogen (LSZH)
insulation. 600/1000 volts grade. Fire resistant to IEC 331 and BS6387, CWZ when tested in steel
conduit. Manufactured to meet the following standards - acid gas emission to BS EN 50267, flame
retardant to BS EN 60332-1-2 and smoke emission to BS7211.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
6491F1/5
6491F2/5
6491F4
6491F6
6491F10
6491F16
1.5
2.5
4.0
6.0
10.0
16.0
7/0.53
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
1
1
1
1
1
1
32
43
55
85
146
198
3.30
3.75
4.30
5.00
6.80
8.00
Temperature limits:
- 40 to + 90°C.
*Bending radius:
8 x Overall Diameter.
Standard colours available:
Brown, Blue, Grey, Black,
Green/Yellow.
Should not be installed at
temperatures below 0°C or
above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
50
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Fire Protection, Alarm & Security Cables
FiRePRooF Mains and contRol caBles lsZH
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke & zero
halogen (LSZH) bedding, galvanised steel wire armour, low smoke & zero halogen (LSZH) outer sheath.
Black. 600/1000 volts. Fire resistant to IEC 331 & BS7846 F2 / BS6387 & CWZ. Acid gas emission
to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation to
BS EN 50265, BS EN 50266 (IEC 60332-3).
CCC
Code
6942F1/5
6943F1/5
6944F1/5
6947F1/5
6940/12F1/5
6940/19F1/5
6940/27F1/5
6940/37F1/5
6942F2/5
6943F2/5
6944F2/5
6947F2/5
6940/12F2/5
6940/19F2/5
6940/27F2/5
6940/37F2/5
6942F4
6943F4
6944F4
6945F4
6947F4
6942F6
6943F6
6944F6
6945F6
6942F10
6943F10
6944F10
6945F10
6942F16
6943F16
6944F16
6945F16
Conductor Stranding
Size
(mm)
(mm2)
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
6
6
6
6
10
10
10
10
16
16
16
16
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
No. Of
Cores
2
3
4
7
12
19
27
37
2
3
4
7
12
19
27
37
2
3
4
5
7
2
3
4
5
2
3
4
5
2
3
4
5
Weight
Outside
(Kg/Km) Diameter
(mm)
295
324
367
463
791
1030
1534
1849
352
392
454
584
1003
1525
1990
2435
424
478
556
725
852
504
573
783
865
620
868
1029
1222
954
1136
1367
1812
12.00
12.50
13.30
15.30
20.00
22.90
27.90
30.70
13.10
13.70
14.70
17.00
22.50
27.00
31.60
34.80
14.10
14.80
16.00
18.12
19.50
15.20
16.00
18.20
19.65
16.90
18.50
20.00
22.64
19.50
20.80
22.50
26.55
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20/16
20S
20S
25
25
32
32
20S
20S
20S
20
25
32
32
40
20S
20S
20
20
20
20
20
20
20
20
20
25
25
25
25
25
25
0.5
0.6
0.6
0.7
0.8
1.0
1.2
1.4
0.6
0.6
0.6
0.7
0.9
1.1
1.4
1.4
0.6
0.6
0.7
0.8
0.8
0.7
0.7
0.8
0.8
0.7
0.8
0.8
0.9
0.8
0.9
0.9
1.1
Temperature limits:
-40 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
5 core and above 4mm2 and
6mm2 - White with Black
numbers.
5 core - 10mm2 and 16mm2 Brown, Black, Grey, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0°C or above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
51
Fire Protection, Alarm & Security Cables
FiRePRooF Mains caBles lsZH
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, low smoke, zero
halogen (LSZH) bedding, galvanised steel wire armour, low smoke, zero halogen (LSZH) outer
sheath. Black. 600/1000 volts grade. Fire resistant to BS6387/BS7846 F2 & CWZ. Acid gas emission
to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC 61034) and flame propagation
to BS EN 50265, BS EN 50266 (IEC 60332-3).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
FP2X25
FP3X25
FP4X25
FP5X25
FP2X35
FP3X35
FP4X35
FP2X50
FP3X50
FP4X50
FP2X70
FP3X70
FP4X70
FP2X95
FP3X95
FP4X95
FP2X120
FP3X120
FP4X120
FP2X150
FP3X150
FP4X150
FP2X185
FP3X185
FP4X185
FP2X240
FP3X240
FP4X240
FP2X300
FP3X300
FP4X300
FP3X400
FP4X400
25
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
400
7/2.14
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
2
3
4
5
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
Weight
Overall
(Kg/Km) Diameter
(mm)
1100
1800
2150
2700
1550
2200
2650
1850
2450
3100
2450
3200
4400
3350
4450
5650
3900
5300
7250
4650
6700
8550
5950
8050
10300
7350
9950
12900
8700
12050
15550
14800
20250
21.4
26.6
28.8
32
24.3
29.1
31.6
26.8
29.6
33.2
30
33.3
38.9
34.1
38.1
42.9
37.1
41.5
48.3
40.3
46.6
52.6
45.7
50.9
57.8
50
56.2
64.2
54.5
61.3
70
67.7
79.3
Gland
Size
(mm)
Nylon
Cleat
Size
25
32
32
32
25
32
32
32
32
40
32
40
40
40
40
50S
40
50S
50
50S
50
50
50
50
63S
50
63S
63
63S
63
75S
75S
90
0.9
1.1
1.2
1.4
1.0
1.2
1.4
1.1
1.2
1.4
1.4
1.4
1.6
1.4
1.6
1.8
1.6
1.8
2.0
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC9
TC11
TC9
TC10
TC12
TC11
TC14
Temperature limits:
-40 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
5 core - Brown, Black, Grey,
Blue, Green/Yellow.
Should not be installed at
temperatures below 0°C or above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
52
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Fire Protection, Alarm & Security Cables
FiRePRooF Mains and contRol caBles
lsZH - enHanced
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape,
low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke
zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following
standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS
EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to
IEC 61034, BS EN 50268.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
FPE2X4
FPE3X4
FPE4X4
FPE2X6
FPE3X6
FPE4X6
FPE2X10
FPE3X10
FPE4X10
FPE2X16
FPE3X16
FPE4X16
4.0
4.0
4.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.7
7/1.7
7/1.7
2
3
4
2
3
4
2
3
4
2
3
4
871
966
959
1001
1087
1252
1060
1180
1350
1290
1460
1690
21.80
22.70
24.00
23.00
23.80
25.20
23.80
24.80
27.40
25.90
27.10
28.98
25
25
25
25
25
25
20
25
32
25
32
32
0.9
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.1
1.2
Temperature limits:
- 40 to + 90°C.
*Bending radius:
8 x Overall Diameter.
Core identification:
2 core - Brown. Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey,
Blue.
Should not be installed at
temperatures below 0°C or
above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
53
Fire Protection, Alarm & Security Cables
FiRePRooF Mains caBles lsZH - enHanced
Plain annealed stranded copper conductor, mica fire resistant tape, XLPE insulated, polyester tape,
low smoke zero halogen (LSZH) bedding, fire barrier tape, galvanised steel wire armour, low smoke
zero halogen (LSZH) outer sheath.Black. 600/1000 grade volts. Manufactured to meet the following
standards - circuit integrity: BS8519-2010 120 minutes/BS8491, acid gas emission to IEC 60754, BS
EN 50267, flame propagation to IEC 60332-3, BS EN 50265, BS EN50266 and smoke emission to
IEC 61034, BS EN 50268.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
FPE2X25
FPE3X25
FPE4X25
FPE2X35
FPE3X35
FPE4X35
FPE2X50
FPE3X50
FPE4X50
FPE2X70
FPE3X70
FPE4X70
FPE2X95
FPE3X95
FPE4X95
FPE2X120
FPE3X120
FPE4X120
FPE2X150
FPE3X150
FPE4X150
FPE2X185
FPE3X185
FPE4X185
FPE2X240
FPE3X240
FPE4X240
FPE2X300
FPE3X300
FPE4X300
FPE3X400
FPE4X400
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120.0
150.0
150.0
150.0
185.0
185.0
185.0
240.0
240.0
240.0
300.0
300.0
300.0
400.0
400.0
7/2.14
7/2.14
7/2.14
7/2.52
7/2.52
7/2.52
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
19/2.52
19/2.52
19/2.52
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
37/2.52
61/2.25
61/2.25
61/2.25
61/2.52
61/2.52
61/2.52
61/2.85
61/2.85
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
1640
2070
2410
2130
2480
2920
2030
2630
3280
2580
3400
4570
3440
4550
5720
4050
5410
7270
4740
6800
8580
6050
8140
10300
7390
10040
12800
8760
12020
15410
14820
19910
29.00
31.10
33.40
31.90
33.50
36.10
29.90
33.20
37.10
33.30
37.00
45.50
37.20
41.20
46.40
39.90
44.40
51.20
43.10
49.30
55.70
48.10
53.70
60.80
52.40
58.80
66.50
56.50
63.50
72.10
70.10
81.30
32
32
40
32
40
40
32
40
40
40
40
50
40
50S
50
50S
50S
50
50S
50
63S
50
63S
63
50
63
75S
63S
63
75
75S
90
1.2
1.4
1.6
1.4
1.4
1.6
1.2
1.4
1.6
1.4
1.6
1.8
1.6
1.8
2.0
1.6
1.8
TC9
1.8
2.0
TC9
2.0
TC9
TC10
TC9
TC10
TC11
TC9
TC10
TC12
TC12
TC14
Temperature limits:
- 40 to + 90°C.
*Bending radius:
8 x Overall Diameter.
Core identification:
2 core - Brown. Blue.
3 core - Brown, Black, Grey.
4 core - Brown, Black, Grey, Blue.
Should not be installed at
temperatures below 0°C or
above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
54
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
SECTION 7 Flexible Cables, PvC And Rubber
Flexible Cables, PvC And Rubber
PVc insulated FleXiBle coRds 218*Y - 318*Y
Plain annealed flexible copper conductors, PVC insulated, PVC outer sheath. Black or White.
300/500 volts grade to BS6500. (Harmonised code HO5VV-F). Flame propagation to BS EN 50265.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
**2182Y/5
**2182Y/75
**2183Y/5
**2183Y/75
3182Y/5
3183Y/5
3182Y/75
3183Y/75
3184Y/75
3185Y/75
3182Y1
3183Y1
3184Y1
3185Y1
3182Y1/5
3183Y1/5
3184Y1/5
3185Y1/5
3182Y2/5
3183Y2/5
3184Y2/5
3185Y2/5
0.5
0.75
0.5
0.75
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
16/0.2
24/0.2
16/0.2
24/0.2
16/0.2
16/0.2
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
2
2
3
3
2
3
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
36
45
44
55
52
54
59
70
85
110
69
82
105
130
95
120
150
180
145
180
220
265
5.4
5.8
5.6
6.1
6.3
6.3
6.8
7.2
7.7
8.5
7.2
7.6
8.5
9.1
8.2
8.9
10.0
11.0
9.9
10.8
11.3
12.8
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20/16
20S
20S
20
20S
20S
20
20
Temperature limits:
Fixed - -5 to +60°C.
Flexing - +5 to +60°C.
*Bending radius:
Fixed 2 x overall diameter.
Flexing 6 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as
per Cenelec HD 308 four core
is available in an alternative
core identification - brown,
black, grey, green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
Should not be installed at temperatures below 0°C.
**Light flexible cords 300/300 volts grade
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
56
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
PVc insulated FleXiBle coRds 309*Y
Plain annealed flexible copper conductors heat resisting PVC outer sheath.
White 300/500 volts grade to BS6141. Flame propagation to BS EN 50265.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
3092Y/5
3093Y/5
3094Y/5
3092Y/75
3093Y/75
3094Y/75
3095Y/75
3092Y1
3093Y1
3094Y1
3092Y1/5
3093Y1/5
3094Y1/5
3092Y2/5
3093Y2/5
3094Y2/5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
2
3
4
2
3
4
5
2
3
4
2
3
4
2
3
4
46
66
70
56
68
85
104
65
77
100
80
100
130
135
150
195
6.3
6.5
7.2
6.8
7.2
7.7
8.5
7.2
7.6
8.5
8.2
8.9
10.0
10.0
10.8
11.8
20/16
20/16
20/16
20S
20S
20S
20S
20S
20S
20S
20S
20S
20
20S
20
20
Temperature limits:
Fixed - -5 to +90°C.
Flexing - +5 to +90°C.
*Bending radius:
Fixed - 2 x overall diameter.
Flexing - 6 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow.
Should not be installed at
temperatures below 0°C.
aRctic GRade FleXiBle coRds
Plain annealed flexible copper conductors, low temperature PVC insulation, low temperature PVC outer
sheath. Blue or Yellow. 300/500 volts grade to BS7919 table 44 and BS6500. Flame propagation to BS
EN 50265.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
3183AG1/5
3184AG1/5
3183AG2/5
3184AG2/5
3183AG4
3183AG6 1.5
1.5
2.5
2.5
4
6
30/0.25
30/0.25
50/0.25
50/0.25
56/0.30
76/0.30
3
4
3
4
3
3
90
130
180
220
240
315
8.20
9.55
10.15
11.30
11.40
13.2 20S
20S
20S
20
20
20
Temperature limits:
Flexing - -40 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per
Cenelec HD 308 four core is
available in an alternative core
identification - brown, black, grey,
green/yellow.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
57
Flexible Cables, PvC And Rubber
ZeRo HaloGen FleXiBle coRds (Ho5 ZiZi-F)
Plain annealed copper conductors, Low smoke and zero halogen (LSZH) insulated, low smoke and zero
halogen (LSZH) outer sheath. Black or white. 300/500 volts grade (Generally to BS6500) Harmonised
code HO5 ZIZI-F. Acid gas emission to BS EN 50267-2(IEC 60754-2), smoke emission to BS EN
50268 (IEC 61034) and flame propagation to BS EN 50265 (IEC 60332-1).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Temperature limits:
-15 to +70°C.
3182B/75
3183B/75
3184B/75
3185B/75
3182B1
3183B1
3184B1
3185B1
3186B1
3182B1/5
3183B1/5
3184B1/5
3185B1/5
3186B1/5
3182B2/5
3183B2/5
3184B2/5
3185B2/5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
24/0.2
24/0.2
24/0.2
24/0.2
32/0.2
32/0.2
32/0.2
32/0.2
32/0.2
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
2
3
4
5
2
3
4
5
6
2
3
4
5
6
2
3
4
5
59
70
85
110
69
82
105
130
136
95
120
150
180
201
145
180
220
265
6.8
7.2
7.7
8.5
7.2
7.6
8.5
9.1
9.8
8.2
8.9
10
11
10.1
9.9
10.8
11.3
12.8
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20S
20/16
20S
20S
20
20S
20S
20S
20
20
*Bending radius:
Fixed 4x overall diameter
Flexing 6x overall diameter
Core identification:
2 core - Brown, Blue.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification
- brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
6 core - Blue, Brown, Black,
Red, White, Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
58
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
tYPe YY contRol caBles
Plain annealed flexible copper conductors, PVC insulated, PVC sheathed.
Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Temperature limits:
-5 to +70°C.
YY2X/75
YY3X/75
YY4X/75
YY5X/75
YY7X/75
YY12X/75
YY18X/75
YY25X/75
YY34X/75
YY50X/75
YY65X/75
YY2X1
YY3X1
YY4X1
YY5X1
YY7X1
YY12X1
YY18X1
YY25X1
YY34X1
YY41X1
YY50X1
YY65X1
YY2X1/5
YY3X1/5
YY4X1/5
YY5X1/5
YY7X1/5
YY8X1/5
YY10X1/5
YY12X1/5
YY18X1/5
YY25X1/5
YY34X1/5
YY50X1/5
YY65X1/5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
2
3
4
5
7
12
18
25
34
50
65
2
3
4
5
7
12
18
25
34
41
50
65
2
3
4
5
7
8
10
12 18
25
34
50
65
46
52
64
77
95
155
221
305
460
578
850
55
66
82
93
121
200
318
415
575
665
815
1055
69
87
110
124
176
230
265
290
424
565
775
1095
1390
5.6
5.7
6.2
7
7.3
9.5
11.1
13.2
16.7
18.4
23.5
6
6.1
6.7
7.5
8.1
11
12.7
15.5
18.3
19
21.3
25.6
6.6
7
7.6
8.1
9.2
11.2
12.4
13.1
14.8
18
21
24.2
28.8
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
25
32
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
32
32
20/16
20/16
20/16
20S
20S
20
20
20
25
25
32
32
40
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Black with White
numbers.
3 core and above - Black
with White numbers plus
Green/Yellow.
Also available with coloured
cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification
- brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
7 core - Blue, Brown, Black,
Grey, White, Red,
Green/Yellow.
Should not be installed at
temperatures below -5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
59
Flexible Cables, PvC And Rubber
tYPe YY contRol caBles
Plain annealed flexible copper conductors, PVC insulated, PVC sheathed.
Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
YY2X2/5
YY3X2/5
YY4X2/5
YY5X2/5
YY7X2/5
YY8X2/5
YY12X2/5
YY18X2/5
YY25X2/5
YY34X2/5
YY3X4
YY4X4
YY5X4
YY7X4
YY3X6
YY4X6
YY5X6
YY7X6
YY3X10
YY4X10
YY5X10
YY3X16
YY4X16
YY5X16
YY3X25
YY4X25
YY5X25
YY4X35
YY5X35
YY4X50
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
25.0
35.0
35.0
50.0
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
396/0.40
2
3
4
5
7
8
12
18
25
34
3
4
5
7
3
4
5
7
3
4
5
3
4
5
3
4
5
4
5
4
106
126
159
178
272
350
403
597
885
1220
201
283
293
413
273
352
415
537
466
631
720
697
767
1151
930
1150
1679
1970
2206
2700
7.8
8.1
8.9
9.7
11.1
13.5
13.8
17.5
22
25.8
10.4
10.7
12.4
14
11.5
12.8
14.6
15.2
15.3
16.5
18.6
18.4
19.9
22.4
21.5
22.5
27.9
29
31.3
34
20/16
20S
20S
20S
20S
20
20
25
32
32
20S
20S
20
25
20
20
25
25
25
25
25
25
32
32
32
32
40
40
40
50S
Temperature limits:
-5 to +70°C.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Black with White
numbers.
3 core and above - Black with
White numbers plus
Green/Yellow.
Also available with coloured
cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification
- brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
7 core - Blue, Brown, Black,
Grey, White, Red,
Green/Yellow.
Should not be installed at
temperatures below -5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
60
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
tYPe sY contRol caBles
Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel
wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and
VDE 0250 class 5.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
SY2X/75
SY3X/75
SY4X/75
SY5X/75
SY7X/75
SY12X/75
SY18X/75
SY25X/75
SY34X/75
SY2X1
SY3X1
SY4X1
SY5X1
SY7X1
SY12X1
SY18X1
SY25X1
SY34X1
SY50X1
SY2X1/5
SY3X1/5
SY4X1/5
SY5X1/5
SY7X1/5
SY12X1/5
SY18X1/5
SY25X1/5
SY34X1/5
SY50X1/5
SY2X2/5
SY3X2/5
SY4X2/5
SY5X2/5
SY7X2/5
SY12X2/5
SY18X2/5
SY25X2/5
SY34X2/5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
2
3
4
5
7
12
18
25
34
2
3
4
5
7
12
18
25
34
50
2
3
4
5
7
12 18
25
34
50
2
3
4
5
7
12
18
25
34
78
91
104
121
135
214
293
418
610
85
95
120
123
171
276
382
437
556
955
100
143
170
173
198
341
490
606
835
1046
177
190
240
247
327
502
740
1065
1126
7.1
7.6
8.3
8.9
9.5
11.9
13.2
13.7
19
7.7
8.2
9
9.2
10.1
12.9
15
17.9
20
23.7
8.2
8.6
9.3
10
10.7
13.8
16.4
19.2
21.6
23.8
9.8
9.9
10.8
11.5
13
16.9
19.8
23.2
24.3
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20
20/16
20/16
20/16
20/16
20/16
20S
20
20
20
25
20/16
20/16
20/16
20/16
20/16
20S
20
20
25
25
20/16
20/16
20/16
20S
20S
20
20
25
25
Temperature limits:
-5 to +70°C.
*Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.
Core identification:
2 core - Black with White
numbers.
3 core and above - Black with
White numbers plus
Green/Yellow.
Also available with coloured
cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
Should not be installed at
temperatures below -5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
61
Flexible Cables, PvC And Rubber
tYPe sY contRol caBles
Plain annealed flexible copper conductors, PVC insulated, extruded PVC bedding, galvanised steel
wire braid armour, transparent PVC outer sheath. 300/500 volts grade generally to BS6500 and
VDE 0250 class 5.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
SY3X4
SY4X4
SY5X4
SY7X4
SY3X6
SY4X6
SY5X6
SY7X6
SY3X10
SY4X10
SY5X10
SY3X16
SY4X16
SY5X16
SY4X25
SY5X25
SY4X35
SY5X35
SY4X50
SY4X70
SY4X95
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
10.0
10.0
10.0
16.0
16.0
16.0
25.0
25.0
35.0
35.0
50.0
70.0
95.0
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40 196/0.40
196/0.40
276/0.40
276/0.40
396/0.40
356/0.50
485/0.50
3
4
5
7
3
4
5
7
3
4
5
3
4
5
4
5
4
5
4
4
4
323
354
392
486
343
458
572
640
563
776
855
813
900
1258
1597
2007
2046
2524
2888
4015
5176
12.2
13.4
15
16
13.4
14.6
16.7
18
17.3
19.1
21
20.5
22.4
25.2
28.2
31.2
31.3
34.3
37
41.2
47.8
20S
20S
20
20
20S
20S
20
20
20
20
25
25
25
25
32
32
40
40
40
50S
50
Temperature limits:
-5 to +70°C.
*Bending radius:
Static - 10 x overall diameter.
Flexing - 20 x overall diameter.
Core identification:
2 core - Black with White
numbers.
3 core and above - Black with
White numbers plus
Green/Yellow.
Also available with coloured
cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
Should not be installed at
temperatures below -5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
62
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
tYPe cY contRol caBles
Plain annealed flexible copper conductors, PVC insulated, mylar taped, tinned copper wire braid
screen, PVC outer sheath. Grey. 300/500 volts grade generally to BS6500 and VDE 0250.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size (mm)
Brass A2
CY2X/5
CY3X/5
CY4X/5
CY5X/5
CY7X/5
CY2X/75
CY3X/75
CY4X/75
CY5X/75
CY7X/75
CY12X/75
CY18X/75
CY25X/75
CY2X1
CY3X1
CY4X1
CY5X1
CY7X1
CY12X1
CY18X1
CY25X1
CY34X1
CY2X1/5
CY3X1/5
CY4X1/5
CY5X1/5
CY7X1/5
CY12X1/5
CY18X1/5
CY25X1/5
CY34X1/5
CY42X1/5
CY2X2/5
CY3X2/5
CY4X2/5
CY5X2/5
CY7X2/5
CY12X2/5
CY2X4 CY3X4
CY4X4
CY5X4 CY4X6
CY4X10
CY4X16
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
6.0
10.0
16.0
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
80/0.40
126/0.40
2
3
4
5
7
2
3
4
5
7
12
18
25
2
3
4
5
7
12
18
25
34
2
3
4
5
7
12 18
25
34
42
2
3
4
5
7
12
2
3
4
5
4 4
4
41
50
66
79
102
43
52
68
80
103
161
238
316
53
64
84
100
125
209
308
420
650
61
78
104
128
159
281
396
534
720
1015
102
117
168
199
252
500
165
186
239
301
327
553
846
5.0
5.2
6.2
7.0
7.2
5.5
5.8
6.5
7.1
7.6
9.9
11.7
13.9
6.3
6.4
7.2
7.8
8.5
11.3
13.3
16.23
19.5
6.5
6.9
7.7
8.6
9.2
12.7
14.7
17.49
19.89
23.8
8
8.4
9.19
10.3
11.2
16.8
10.5
10.3
11.8
13
12.9
17.2
21
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20
20
20/16
20/16
20/16
20/16
20/16
20S
20
25
25
20/16
20/16
20/16
20S
20
25
25
25
32
25
20/16
20/16
20S
20S
20S
25
20S
20S
20S
20S
20S
25
32
Temperature limits:
Static - -20 to +80°C.
Flexing - -5 to +70°C.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Black with White
numbers.
3 core and above - Black with
White numbers plus
Green/Yellow.
Also available with coloured
cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively as per Cenelec HD 308 four
core is available in an
alternative core identification
- brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black,
Grey, Green/Yellow.
Should not be installed at
temperatures below -5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
63
Flexible Cables, PvC And Rubber
tYPe YY contRol caBles lsZH
Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH) insulated, low smoke
and zero halogen (LSZH) sheathed. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
YY2X/75LSF
YY3X/75LSF
YY4X/75LSF
YY5X/75LSF
YY7X/75LSF
YY12X/75LSF
YY2X1LSF
YY3X1LSF
YY4X1LSF
YY5X1LSF
YY2X1/5LSF
YY3X1/5LSF
YY4X1/5LSF
YY5X1/5LSF
YY7X1/5LSF
YY12X1/5LSF
YY18X1/5LSF
YY25X1/5LSF
YY34X1/5LSF
YY2X2/5LSF
YY3X2/5LSF
YY4X2/5LSF
YY5X2/5LSF
YY7X2/5LSF
YY3X4LSF
YY4X4LSF
YY5X4LSF
YY7X4LSF
YY3X6LSF
YY4X6LSF
YY5X6LSF
YY3X10LSF
YY4X10LSF
YY5X10LSF YY3X16LSF
YY4X16LSF
YY3X25LSF
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4
6.0
6.0
6.0 10.0
10.0
10.0
16.0
16.0
25.0
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
24/0.2
32/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.3
56/0.3
56/0.3
84/0.30
84/0.3
84/0.30
80/0.40
80/0.4
80/0.40
126/0.4
126/0.4
196/0.40
2
3
4
5
7
12
2
3
4
5
2
3
4
5
7
12
18
25
34
2
3
4
5
7
3
4
5
7
3
4
5
3
4
5
3
4
3
46
52
64
77
95
155
55
66
82
93
69
87
110
124
176
290
424
565
775
106
126
159
178
272
201
283
293
413
273
352
415
466
631
720
697
767
930
5.6
5.7
6.2
7
7.3
9.5
6
6.1
6.7
7.5
6.6
7
7.6
8.1
9.2
13.1
14.8
18
21
7.8
8.1
8.9
9.7
11.1
10.4
10.7
12.4
14
11.5
12.8
14.6
15.3
16.5
18.6
18.4
19.9
21.5
20/16
20/16
20/16
20/16
20/16
20S
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
32
20/16
20S
20S
20S
20
20S
20S
20
25
20
20
25
25
25
25
25
32
32
tYPe cY contRol caBles lsZH
Temperature limits: -5 to 70°C.
*Bending radius:
Static - 6 x Overall Diameter
Flexible - 15 x Overall Diameter.
Core identification:
2 Core - Black with White numbers.
3 Core and above
Black with White numbers plus
Green/Yellow.
Also available with coloured cores as follows:
2 core - Blue, Brown.
3 core - Blue, Brown, Green/Yellow.
4 core - Blue, Brown, Black,
Green/Yellow alternatively
as per Cenelec HD 308 four core is available in an alternative core
identification - brown, black, grey,
green/yellow.
5 core - Blue, Brown, Black, Grey,
Green/Yellow.
Plain annealed flexible copper conductors, low smoke and zero halogen (LSZH)
Should not be installed at
insulated, mylar taped, tinned copper wire braid, low smoke and zero halogen
temperatures below -5°C.
(LSZH) outer sheath. Grey. 300/500 volts grade, generally to BS6500 and VDE 0250.
CCC
Code
Conductor
Size
(mm2)
CY2X/75LSF
CY3X/75LSF
CY4X/75LSF
CY5X/75LSF
CY7X/75LSF
CY2X1/5LSF
CY3X1/5LSF
CY4X1/5LSF
CY5X1/5LSF
CY12X1/5LSF
CY18X1/5LSF
CY25X1/5LSF
CY34X1/5LSF
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
2
3
4
5
7
2
3
4
5
12
18
25
34
43
52
68
80
103
61
78
104
128
281
396
534
720
5.5
5.8
6.5
7.1
7.6
6.5
6.9
7.7
8.6
12.7
14.7
17.49
19.89
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
20/16
25
25
25
32
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
64
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
Temperature limits:
- 5 to + 70°C
tYPe sY contRol caBles lsZH
Plain annealed flexible copper conductors, low smoke and zero halogen
(LSZH) insulated, low smoke and zero halogen (LSZH) sheathed. Black. Bending radius: Static - 10 x overall diameter.
300/500 volts grade generally to BS6500 and VDE 0250
Flexing - 20 x overall diameter.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No
Of Cores
Weight
Kg/Km
Overall
Diameter
(mm)
Gland
Size
(mm)
SY3X1/5LSF
SY4X1/5LSF
SY3X2/5LSF
SY4X2/5LSF
SY3X4LSF
SY3X6LSF
1.5
1.5
2.5
2.5
4
6
30/0.25
30/0.25
50/0.25
50/0.25
56/0.3
84/0.30
3
4
3
4
3
3
143
170
190
240
323
343
8.6
9.3
9.9
10.8
12.2
13.4
20/16
20/16
20/16
20/16
20s
20s
Core identification
3 core and above - black with white
numbers plus green/yellow
also available with coloured cores as follows: 3 core - Blue, Brown, Green/Yellow
4 core - Blue, Brown, Black,
Green/Yellow alternatively
as per cenelec HD308 four core is
available in an alterative core
identification - brown, black, grey,
green/yellow.
Should not be installed at
temperatures below - 5°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
65
Flexible Cables, PvC And Rubber
tRi-Rated eQuiPMent WiRes
Plain annealed stranded circular copper conductors, circular high temperature PVC outer sheath.
UL & CSA approved also to BS6231. 600/1000 volts grade. Flame propagation to BS EN 50265 and
IEC 60332-1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
TRI0/5
TRI/75
TRI1
TRI1/5
TRI2/5
TRI4
TRI6
TRI10
TRI16
TRI25
TRI35
TRI50
TRI70
TRI95
TRI120
BI150
BI185
BI240
BI300
BI400
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150
185
240
300
400
16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
12
15
18
23
34
50
71
123
207
303
412
607
837
1079
1280
1619
1948
2518
3112
4051
2.7
2.9
3.1 3.3
3.7
4.3
4.9
6.3
9.0
10.4
11.9
14.7
16.8
18.8
19.9
22.9
24.1
28.6
32.2
36
20/16
20/16
20/16
20/16
20/16
20S
20S
20
25
25
25
32
32
32
40
50S
50
Temperature limits: -30 to +105°C.
*Bending radius:
6 x Overall diameter.
Standard colours available:
0.5mm2 - 2.5mm2 - Brown,
Black, Grey, Blue,
Green/Yellow, Red, Yellow,
White, Orange, Pink, violet.
4.0mm2 - 16mm2 - Brown,
Black, Grey, Blue,
Green/Yellow, Red, Yellow,
White. 25.0mm2 - 120mm2 - Brown,
Black, Grey, Blue,
Green/Yellow, Red, Yellow.
150mm2 - Black, Green/Yellow.
185mm2 - 400mm2 - Black.
Should not be installed at
temperatures below 0°C.
2491B/6701B lsZH FleXiBle sinGle coRes
Flexible plain annealed copper conductor, low smoke zero halogen (LSZH) outer sheath to BS7211.
0.75mm/1.0mm rated at 300/500 volts grade, harmonised code HO5Z-K. 1.5mm to 240mm rated
at 450/750 volts grade, harmonised code HO7Z-K. Flame propagation to BS EN 50266-1:2001
(formerly BS4066:PT1).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
2491B/75
2491B1
2491B1/5
2491B2/5
2491B4
2491B6
6701B10
6701B16
6701B25
6701B35
6701B50
6701B70
6701B95
6701B120
6701B150
6701B185
6701B240
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
24/0.20
32/0.20
30/0.25
50/0.25
56/0.25
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
12
14
20
30
45
65
110
160
250
340
480
670
890
1140
1410
1710
2270
2.12
2.48
2.98
3.63
4.23
4.83
6.10
7.10
8.70
9.90
11.60
13.30
15.20
17.00
18.90
21.00
23.90
Temperature limits:
- 15 to + 90°C
*Bending radius:
up to 35mm2 - 3 x Overall
Diameter
50mm2 and above - 4 x
Overall diameter.
Standard colours available:
1.5mm to 6mm - Black, Blue,
Brown, Grey,
Orange, White, Red, Yellow,
Green/Yellow.
10mm2 - 240mm2 - Black,
Blue, Brown, Grey.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
66
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
solaR eneRGY caBles
Electrolytic annealed tinned flexible copper conductor, halogen free thermosetting rubber insulation,
type EI6 according to EN 50363-1 and table 4 of the TUV standard, halogen free thermosetting
rubber outer sheath, type EM8 according to EN 50363-1 and table 4 of the TUV standard. Black.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
SOLAR1X1/5BK SOLAR1X2/5BK
SOLAR1X4BK
SOLAR1X6BK
SOLAR1X10BK SOLAR1X16BK SOLAR1X25BK SOLAR1X35BK 1.5
2.5
4.0
6.0
10
16
25
35
29/0.25
48/0.25
48/0.3
72/0.3
126/0.3
116/0.4
180/0.4
260/0.4
1
1
1
1
1
1
1
1
40
49
66
86
132
188
294
390
4.90
5.35
6.00
6.55
7.60
8.60
10.80
11.90
Characteristics.
Nominal voltage: AC: 0,6/1 kV; DC: 1,8 kV.
Ambient temperature range: -40 °C to + 90 ºC.
Maximum conductor temperature: 120 ºC.
Maximum short-circuit temperature: 250 °C (maximum 5 s).
*Minimum bending radius (fixed): 5 x cable Ø.
No flame propagation: EN 60332-1-2 / IEC 60332-1-2.
No fire propagation: EN 60332-3 / IEC 60332-3.
Halogen free: according to EN 50267 / IEC 60754
HCl content < 0,5%.
pH > 4,3.
conductivity < 10 !S/mm.
Smoke density: light transmittance > 60% (according to EN 61034/IEC 61034).
sinGle coRe PVc FleXiBle Mains caBles
Plain annealed flexible copper conductor, PVC insulated PVC sheathed, 450/750 volts, generally to
BS6004 & IEC60502. Flame propagation to BS4066 PT1 & IEC332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
6381Y6
6381Y10
6381Y16
6381Y25
6381Y35
6381Y50
6381Y70
6381Y95
6381Y120
6381Y150
6381Y185
6381Y240
6381Y300
6381Y400
6.0
10.00
16.0
25.0
35.0
50.0
70.0
95.0
120.0
150.0
185.0
240.0
300.0
400.0
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
1
1
1
1
1
1
1
1
1
1
1
1
1
1
105
151
208
303
401
560
748
990
1233
1528
1857
2419
3032
3937
7.7
8.8
9.9
11.4
12.7
14.6
16.1
18.6
20.2
22.5
25.1
28.3
31.2
35.4
20/16
20S
20S
20
20
25
25
25
32
32
32
40
40
50S
Temperature limits:
-15 to +70°C.
*Bending radius:
Up to 50mm 3 x overall
diameter.
Over 70mm 5 x overall
diameter.
Standard core colours
available:
Black, grey, blue, brown,
green/yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
67
Flexible Cables, PvC And Rubber
FleXiBle Mains and contRol caBles ePR,csP
Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated,
chlorosulphonated polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500. Black or
White. Heat and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS
EN 50265-2-1). Harmonised code H07BN4-F.
CCC
Code
Conductor
Size
(mm2)
3182TQ/75
3183TQ/75
3184TQ/75
3182TQ1
3183TQ1
3184TQ1
3181TQ1/5
3182TQ1/5
3183TQ1/5
3184TQ1/5
3185TQ1/5
3186TQ1/5
3187TQ1/5
3180/12TQ1/5
3180/16TQ1/5
3180/20TQ1/5
3180/27TQ1/5
3180/37TQ1/5
3181TQ2/5
3182TQ2/5
3183TQ2/5
3184TQ2/5
3185TQ2/5
3187TQ2/5
3180/12TQ2/5
3180/16TQ2/5
3180/20TQ2/5
3180/27TQ2/5
3180/37TQ2/5
0.75
0.75
0.75
1.0
1.0 1.0
1.5 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20 30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
2
3
4
2
3
4
1
2
3 4
5
6
7
12
16
20
27
37
1
2
3
4
5
7
12
16
20
27
37
58
72
86 80
90
110
38
115
135
170
200
335
366
410
570
710
920
1260
41
160
195
245
300
424
600
780
1050
1390
1720
Mean Overall Diameter
(mm)
Lower Limit Upper Limit
5.7
6.2
6.8
6.1
6.5
7.1
5.7
7.6
8.0
9.0
11.2
13.4
14.6
17.6
19.8
21.4
25.3
29.0
6.3
9.0
9.6
10.7
13.3
17.2
20.6
23.8
26.4
30.1
35.0
7.4
8.1
8.8
8.0
8.5
9.3
7.1
9.8
10.4
11.6
14.4
17.2
18.2
22.4
24.3
26.7
30.0
34.2
7.9
11.6
12.4
13.8
17.0
21.0
26.2
28.4
31.2
35.4
40.9
Temperature limits:
-25 to +90°C.
*Bending radius:
Fixed - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below -25°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
68
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
FleXiBle Mains caBles ePR,csP
Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated,
chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat
and oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 502652-1). Harmonised code H07BN4-F.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
6381TQ4
6382TQ4
6383TQ4
6384TQ4
6385TQ4
6387TQ4
6380/12TQ4
6381TQ6
6382TQ6
6383TQ6
6384TQ6
6385TQ6
6387TQ6
6388TQ6
6381TQ10
6382TQ10
6383TQ10
6384TQ10
6385TQ10
6381TQ16
6382TQ16
6383TQ16
6384TQ16
6385TQ16
4.0
4.0
4.0
4.0
4.0
4.0
4.0
6
6
6
6
6
6
6
10
10
10
10
10
16
16
16
16
16
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40
1
2
3
4
5
7
12
1
2
3
4
5
7
8
1
2
3
4
5
1
2
3
4
5
105
275
335
420
515
773
1183
130
370
450
565
690
904
1040
200
690
835
1020
1240
275
910
1120
1380
1695
Mean Overall Diameter
(mm)
Lower Limit Upper Limit
7.2
11.8
12.7
14.0
15.6
19.8
24.4
7.9
13.1
14.1
15.7
17.5
21.6
25.2
9.5
17.7
19.1
20.9
22.9
10.8
20.2
21.8
23.8
26.4
9.0
15.1
16.2
17.9
19.9
24.4
30.9
9.8
16.8
18.0
20.0
22.9
26.9
29.6
11.9
22.6
24.2
26.5
29.1
13.4
25.7
27.6
30.1
33.3
Temperature limits:
-25 to +90°C.
*Bending radius:
Fixed - 6 x overall diameter.
Flexing - 7 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below -25°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
69
Flexible Cables, PvC And Rubber
FleXiBle Mains caBles ePR,csP
Tinned annealed flexible copper conductors, ethylene propylene rubber (EPR) insulated,
chlorosulphonated polyethylene (CSP) outer sheath. Black. 450/750 volts grade to BS7919. Heat and
oil resistant and flame retardant (HOFR). Flame retardant to BS EN 60332-1-2 (BS EN 50265-2-1).
Harmonised code H07BN4-F.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
6381TQ25
6382TQ25
6383TQ25
6384TQ25
6385TQ25
6381TQ35
6382TQ35
6383TQ35
6384TQ35
6385TQ35
6381TQ50
6383TQ50
6384TQ50
6385TQ50
6381TQ70
6383TQ70
6384TQ70
6385TQ70
6381TQ95
6383TQ95
6384TQ95
6385TQ95
6381TQ120
6383TQ120
6384TQ120
6385TQ120
6381TQ150
6383TQ150
6384TQ150
6381TQ185
6383TQ185
6384TQ185
6381TQ240
6383TQ240
6384TQ240
6381TQ300
6383TQ300
6384TQ300
6381TQ400
6381TQ500
6381TQ630
25
25
25
25
25
35
35
35
35
35
50
50
50
50
70
70
70
70
95
95
95
95
120
120
120
120
150
150
150
185
185
185
240
240
240
300
300
300
400
500
630
196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
396/0.40
396/0.40
360/0.50
360/0.50
360/0.50
360/0.50
475/0.50
475/0.50
475/0.50
475/0.50
608/0.50
608/0.50
608/0.50
608/0.50
756/0.50
756/0.50
756/0.50
925/0.50
925/0.50
925/0.50
1221/0.50
1221/0.50
1221/0.50
1525/0.50
1525/0.50
1525/0.50
2013/0.50
1769/0.60
2257/0.60
1
2
3
4
5
1
2
3
4
5
1
3
4
5
1
3
4
5
1
3
4
5
1
3
4
5
1
3
4
1
3
4
1
3
4
1
3
4
1
1
1
400
1290
1600
2140
2470
520
1308
2080
2610
3187
730
2890
3650
4450
980
3850
4880
5938
1270
4970
6390
7924
1570
6350
7750
7542
1960
7700
9780
2380
9350
11900
3100
12000
15330
3790
14910
19030
4880
6070
7460
Mean Overall Diameter
(mm)
Lower Limit Upper Limit
12.7
24.3
26.1
28.9
32.0
14.3
26.4
29.3
32.5
34.0
16.5
34.1
37.7
39.03
18.6
38.4
42.7
48.5
20.8
43.3
48.4
54.0
22.8
47.4
53.0
57.9
25.2
52.0
58.0
27.6
57.0
64.0
30.6
65.0
72.0
33.5
72.0
80.0
37.4
41.3
45.5
15.8
30.7
33.0
36.6
40.4
17.9
31.5
37.1
41.1
43.0
20.6
42.9
47.5
49.18 23.3
48.3
54.0
55.0
26.0
54.0
61.0
64.5
28.6
60.0
66.0
58.5
31.4
66.0
73.0
34.4
72.0
80.0
38.3
82.0
91.0
41.9
90.0
101.0
46.8
52.0
56.5
Temperature limits:
-25 to +90°C.
*Bending radius:
Fixed - 5 x overall diameter.
Flexing - 7 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below -25°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
70
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
FleXiBle Mains and contRol caBles Ho7Rn-F
Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP)
outer sheath 450/750 volts grade. Black. Harmonised code type HO7RN-F. Flame propagation to
EN 60332-1-2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
3182P1
3183P1
3184P1
3182P1/5
3183P1/5
3184P1/5
3185P1/5
3187P1/5
3180/12P1/5
3180/19P1/5
3180/27P1/5
3180/37P1/5
3182P2/5
3183P2/5
3184P2/5
3185P2/5
3187P2/5
3180/12P2/5
3181P4
3182P4
3183P4
3184P4
3185P4
3187P4
6381P6
6382P6
6383P6
6384P6
6385P6
6387P6
6381P10
6382P10
6383P10
6384P10
6385P10
6381P16
6382P16
6383P16
6384P16
6385P16
6381P25
6382P25
6383P25
6384P25
6385P25
6381P35
6383P35
6384P35
6385P35
6381P50
6383P50
6384P50
6385P50
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4.0
4.0
4.0
4.0
4
6
6.0
6.0
6.0
6.0
6.0
10
10
10
10
10
16
16
16
16
16
25
25
25
25
25
35
35
35
35
50
50
50
50
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
56/0.30
56/0.30
56/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
84/0.30
80/0.40
80/0.40
80/0.40
80/0.40
80/0.40
126/0.40
126/0.40
126/0.40
126/0.40
126/0.40
196/0.40
196/0.40
196/0.40
196/0.40
196/0.40
276/0.40
276/0.40
276/0.40
276/0.40
396/0.40
396/0.40
396/0.40
396/0.40
2
3
4
2
3
4
5
7
12
19
27
37
2
3
4
5
7
12
1
2
3
4
5
7
1
2
3
4
5
7
1
2
3
4
5
1
2
3 4
5
1
2
3
4
5
1
3
4
5
1
3
4
5
95
115
140
132
165
200
240
385
520
700
920
1260
193
235
290
345
520
810
94
275
320
395
485
773
130
350
495
610
760
904
230
640
880
1060
1300
320
850
1090
1345
1680
450
1210
1394
1995
2470
605
1850
2645
2930
825
2890
3635
4450
Mean Overall Diameter
(mm)
Lower Limit Upper Limit
6.1
6.5
7.1
7.6
8.0
9.0
11.2
14.6
17.6
25.3
29
9.0
9.6
10.7
13.3
17.2
20.6
7.2
11.8
12.7
14.0
15.6
19.8
7.9
13.1
14.1
15.7
17.5
21.6
9.5
17.7
19.1
20.9
22.9
10.8
20.2
21.8
23.8
26.4
12.7
24.3
26.1
28.9
32.0
14.3
29.3
32.5
34.0
16.5
34.1
37.7
39.03
8.0
8.5
9.3
9.8
10.4
11.6
14.4
18.2
22.4
21 26
30
34.2
11.6
12.4
13.8
17.0
21.0
26.2
9
15.1
16.2
17.9
19.9
24.4
9.8
16.8
18.0
20.0
22.9
26.9
11.9
22.6
24.2
26.5
29.1
13.4
25.7
27.6
30.1
33.3
15.8
30.7
33.0
36.6
40.4
17.9
37.1
41.1
43.0
20.6
42.9
47.5
49.18
Temperature limits:
-25 to +60°C. Can be supplied suitable for up to 90°C upon special request.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
71
Flexible Cables, PvC And Rubber
FleXiBle Mains and contRol caBles Ho7Rn-F
Plain annealed flexible copper conductors, rubber insulated, heavy duty polychloroprene (PCP)
outer sheath 450/750 volts grade. Black. Harmonised code type HO7RN-F. Flame propagation
to EN 60332-1-2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
6381P70
6383P70
6384P70
6385P70
6381P95
6383P95
6384P95
6385P95
6381P120
6383P120
6384P120
6381P150
6383P150
6384P150
6381P185
6383P185
6384P185
6381P240
6383P240
6384P240
6381P300
6381P400
6381P500
6381P630
70
70
70
70
95
95
95
95
120
120
120
150
150
150
185
185
185
240
240
240
300
400
500
630
360/0.50
360/0.50
360/0.50
360/0.50
475/0.50
475/0.50
475/0.50
475/0.50
608/0.50
608/0.50
608/0.50
756/0.50
756/0.50
756/0.50
925/0.50
925/0.50
925/0.50
1221/0.50
1221/0.50
1221/0.50
1525/0.50
2257/0.50
1769/0.60
2257/0.60
1
3
4
5
1
3 4
5
1
3
4
1
3
4
1
3
4
1
3
4
1
1
1
1
1090
3850
4830
5938
1405
4185
6320
6695
1745
5051
6453
1824
6267
8031
2202
7661
9830
2847
9692
12444
3495
4880
5301
7460
Mean Overall Diameter
(mm)
Lower Limit Upper Limit
18.6
38.4
42.7
48.5
20.8
43.3
48.5
54.0
22.8
47.4
53.0
25.2
52.0
58.0
27.6
57.0
64.0
30.6
65.0
72.0
33.5
45.5
41.3 45.5 23.3
48.3
54.0
55.0
26.0
50
61.0
64.5
28.6
60.0
66.0
31.4
66.0
73.0
34.4
72.0
80.0
38.3
82.0
91.0
41.9
56.5
52.0
56.5 Temperature limits:
-25 to +60°C.
Can be supplied suitable for up to 90°C upon special request.
*Bending radius:
Static - 6 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
72
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
touGH RuBBeR sHeatH FleXiBle coRds
Flexible tinned annealed copper conductors, ethylene propylene rubber insulated, tough rubber sheath.
Black. 300/500 volts grade to BS6500 and BS7919.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
3182/75
3183/75
3184/75
31821
31831
31841
31821/5
31831/5
31841/5
31851/5
31822/5
31832/5
31842/5
31852/5
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
24/0.20
24/0.20
24/0.20
30/0.20
30/0.20
30/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
50/0.25
2
3
4
2
3
4
2
3
4
5
2
3
4
5
63
78
94
77
90
110
115
135
170
195
165
195
245
290
6.6
7.2
7.8
7.1
7.5
8.2
8.7
9.2
9.8
10.3
10.3
11.0
11.9
12.3
20/16
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20S
20S
20S
20
20
Temperature limits:
+60°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core - Grey, Black, Brown,
Blue, Green/Yellow.
Should not be installed at
temperatures below 0°C.
BRaided touGH RuBBeR sHeatH FleXiBle coRds
Flexible tinned annealed copper conductors, ethylene propylene rubber insulated,
chlorosulphonated polyethylene bedding (CSP), tinned copper wire braid screen, chlorosulphonated
polyethylene (CSP) outer sheath. 300/500 volts grade to BS6500/75 and 450/750 Volts grade to
BS6007/75 (where applicable). Black. Flame propagation to BS 4066 PT1 and IEC 332 PT1.
Heat and oil resistant and flame retardant (HOFR).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
3802TQ1
3803TQ1
3804TQ1
3802TQ1/5
3803TQ1/5
3804TQ1/5
3802TQ2/5
3803TQ2/5
3804TQ2/5
3803TQ4
3804TQ4
6803TQ6
6804TQ6
6803TQ10
6804TQ10
6803TQ16
6804TQ16
1.0
1.0
1.0
1.5
1.5
1.5
2.5
2.5
2.5
4.0
4.0
6.0
6.0
10.0
10.0
16.0
16.0
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
56/0.30
84/0.30
84/0.30
90/0.40
90/0.40
126/0.40
126/0.40
2
3
4
2
3
4
2
3
4
3
4
3
4
3
4
3
4
170
200
230
225
270
320
300
350
420
715
865
973
1166
1592
1878
1992
2452
11.1
11.4
12.1
12.3
13.1
14.2
14.8
15.6
17.0
21.3
23.6
24.8
27.1
30.7
33.3
33.8
37.2
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
25
25
25
32
32
40
40
40
Temperature limits:
-25 to +90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown, Blue,
Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
73
Flexible Cables, PvC And Rubber
coil end lead FleXiBle Mains caBles
Flexible tinned annealed copper conductors composite ethylene propylene rubber chlorosulphonated
polyethylene (EPR-CSP) insulation to BS6195/69 Type 4.
A. 300/500 volts grade
C. 600/1000 volts grade
D. 1900/3300 volts grade
E. 3800/6600 volts grade
F. 6350/11000 volts grade
Conductor
CCC
Code
Size
(mm2)
Stranding
(mm)
TYPE 4 1/5
TYPE 4 2/5
TYPE 4 4
TYPE 4 6
TYPE 4 10
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400
TYPE 4 500
0.5
0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
16/0.20
24/0.20
32/0.20
30/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
608/0.50
756/0.50
925/0.50
1221/0.50
1525/0.50
2013/0.50
3679/0.40
CCC
Code
Approx.
Max
Dia. Of Dia. Of
Wires Cond.
(mm) (mm)
0.21
0.21
0.21
0.26
0.26
0.31
0.31
0.41
0.41
0.41
0.41
0.41
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.51
0.61
0.93
1.14
1.32
1.60
2.00
2.6
3.6
4.6
5.7
7.1
8.5
10.3
12.4
14.5
16.0
18.0
20.0
23.0
26.0
30.0
29.0
Radial Thickness Of Insulation
Voltage Category
A
C
D
E
F
(mm) (mm)
(mm) (mm) (mm)
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.2
-
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.5
1.5
1.6
1.6
1.7
1.8
2.0
2.2
2.3
2.4
2.4
2.6
2.8
3.0
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.0
3.0
3.0
3.0
3.0
3.0
-
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
-
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
-
Temperature limits:
-20 to +90°C.
*Bending radius:
6 x overall diameter.
Should not be installed at
temperatures below -25°C.
Minimum Overall Diameter
Weight
Voltage Category
Voltage Category
A
C
D
E
F
A
C
D
E
F
(mm) (mm) (mm) (mm) (mm) (Kg/Km) (Kg/Km)(Kg/Km)(Kg/Km) (Kg/Km)
3.3
3.5
3.7
TYPE 4 1/5 4.0
TYPE 4 2/5 4.6
TYPE 4 4
5.4
TYPE 4 6
6.5
TYPE 4 10
7.9
TYPE 4 16
TYPE 4 25
TYPE 4 35
TYPE 4 50
TYPE 4 70
TYPE 4 95
TYPE 4 120
TYPE 4 150
TYPE 4 185
TYPE 4 240
TYPE 4 300
TYPE 4 400
TYPE 4 500
-
4.5
4.7
4.9
5.2
5.6
6.3
7.5
8.5
9.6
11.4
12.8
14.8
17.2
19.7
21.9
24.1
26.3
29.3
33.0
37.4
34.8
8.5
12.4
13.8
15.2
17.1
19.2
22.0
23.5
25.5
27.5
30.5
33.8
37.8
-
17.2
18.6
20.0
21.1
24.2
26.3
27.8
29.8
32.1
35.1
-
22.9
24.1
25.5
27.3
29.4
31.5
33.3
35.3
37.3
40.3
-
12
16
19
25
37
57
80
130
-
17
21
24
30
41
66
93
136
206
300
406
573
793
1028
1285
1562
1914
2431
3024
3948
4920
76
255
351
458
616
820
1097
1340
1635
1973
2504
3098
4045
-
384
495
613
796
1020
1287
1542
1853
2225
2782
-
566
680
810
997
1237
1520
1804
2131
2503
3081
-
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
74
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Flexible Cables, PvC And Rubber
WeldinG caBles 0361tQ
Tinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated,
chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flame
retardant to BS EN 60332-1-2 (BS EN 50265-2-1).
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
Weight
(Kg/Km)
Outside
Diameter
(mm)
Gland
Size
(mm)
0361TQ16OR 0361TQ25OR
0361TQ35OR
0361TQ50OR
0361TQ70OR
0361TQ95OR
0361TQ120OR
0361TQ185OR
16
25
35
50
70
95
120
185
513/0.20
783/0.20
1107/0.20
1566/0.20
2214/0.20
2997/0.20
608/0.50
925/0.50
235
330
440
610
840
1120
1410
2100
11.5
13.0
14.5 17.0
19.5
22.0
24.0
29.0
20S
20
25
25
32
32
32
40
Temperature limits:
-20 to +85°C.
*Bending radius:
8 x overall diameter.
RuBBeR FlatFoRM caBles
Flexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath
(TPR). Black. 600/1000 volts grade.
CCC
Current
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Dimensions
(mm)
Max
Ratings
(Amps)
FLAT4X1/5R
FLAT12X1/5R
FLAT4X2/5R
FLAT7X2/5R
FLAT12X2/5R
FLAT4X4R
FLAT4X6R
FLAT4X10R
FLAT4X16R
FLAT4X25R
FLAT4X35R
FLAT4X50R
FLAT4X70R
1.5
1.5
2.5
2.5
2.5
4
6
10
16
25
35
50
70
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
4
12
4
7
12
4
4
4
4
4 4
4
4
110 320
170
300
490
250
330
550
800
1350
1800
2400
3250
16X5
29X5
19X6
33X7
51X6
21X7
24X7
29X9
35X10
46X14
51X15
56X17
63X18
22
12
30
20
20
40
52
70
95
127
157
190
242
Temperature limits:
-35 to +85°C.
*Bending radius:
10 x overall diameter.
Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.
7 and 12 core - Black cores
with White numbers and one
Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
75
Flexible Cables, PvC And Rubber
PVc FlatFoRM caBles
Flexible plain copper conductors, PVC insulated, special PVC outer sheath. Black. 450/750 volts grade
type H07VVH6-F. CENELEC HD 359 S2 IEC 227 part 6.
CCC
Current
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Dimensions
(mm)
Max
Ratings
(Amps)
FLAT4X1/5v
FLAT12X1/5v
FLAT4X2/5v
FLAT12X2/5v
FLAT4X4v
FLAT4X6v
FLAT4X10v
FLAT4X16v
FLAT4X25v
FLAT4X35v
FLAT4X50v
FLAT4X70v
FLAT4X95v
1.5
1.5
2.5
2.5
4
6
10
16
25
35
50
70
95
30/0.25
30/0.25
50/0.25
50/0.25
56/0.30
84/0.30
80/0.40
126/0.40
196/0.40
276/0.40
396/0.40
360/0.50
475/0.50
4
12
4
12
4
4
4
4
4
4 4
4
4
150 420
210
620
300
385
620
990
1550
2030
2650
3650
4550
15X5
41X5
19X6
51X6
21X7
23X7
29X9
37X11
46X14
51X15
56X17
63X18
73X21
20
11
27
16
36
48
63
85
112
138
168
213
258
Temperature limits:
-25 to +70°C.
*Bending radius:
10 x overall diameter.
Core identification:
4 core - Black, Grey, Brown,
Green/Yellow.
12 core - Black cores with white numbers and one Green/Yellow.
Should not be installed at temperatures below 0°C.
silicon FleXiBle caBles siHF
Flexible tinned annealed copper conductors, silicone insulated, silicone outer sheath. 300/500 volts
grade to VDE 0250 PT816.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
BIHF2X/75
BIHF3X/75
BIHF4X/75
BIHF2X1
BIHF3X1
BIHF4X1
BIHF2X1/5
BIHF3X1/5
BIHF4X1/5
BIHF5X1/5
BIHF2X2/5
BIHF3X2/5
BIHF4X2/5
0.75
0.75
0.75
1.0
1.0
1.0
1.5
1.5
1.5
1.5
2.5
2.5
2.5
24/0.20
24/0.20
24/0.20
32/0.20
32/0.20
32/0.20
30/0.25
30/0.25
30/0.25
30/0.25
50/0.25
50/0.25
50/0.25
2
3
4
2
3
4
2
3
4
5
2
3
4
53.4
63.7
83.6
59.9
78.3
94.6
82.0
98.0
122.0
148.0
135.0
152.0
188.0
6.5
6.9
7.9
6.7
7.5
8.1
7.6
8.0
8.8
9.6
8.9
9.1
10.1
20/16
20/16
20/16
20/16
20/16
20S
20/16
20/16
20S
20S
20S
20S
20S
Temperature limits:
-60 to +180°C.
*Bending radius:
Fixed - 5 x overall diameter.
Flexing - 15 x overall
diameter.
Core identification:
2 core - Blue, Brown.
3 core - Blue, Brown,
Green/Yellow.
4 core - Grey, Black, Brown,
Green/Yellow.
5 core and above - Grey,
Black, Brown, Blue,
Green/Yellow.
6 core and above - Black with
White numbers plus
Green/Yellow.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
76
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
SECTION 8 Instrumentation, Control & Communication Cables
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective
aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation,
Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
PAS5308 PART 2, TYPE 1 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective
aluminium/mylar tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced propagation.
Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
Pt1
CCC Code
Pt2
7100
7101
7102
7103
7104
7105
7106
7107
7136
7137
7138
7139
7140
7141
7142
7143
7173
7174
7175
7176
7177
N/A
N/A
7178
72700
72701
72702
72703
72704
72705
72707
7300
7301
7302
7303
7304
7305
7306
7307
7336
7337
7338
7339
7340
7341
7342
7343
7373
7374
7375
7376
7377
N/A
N/A
7378
-
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
16/0.2
16/0.2
16/0.2
16/0.2
16/0.2
16/0.2
16/0.2
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
30
1 TRIPLE
Weight
Outside
(Kg/Km) Diameter
(mm)
60
75
190
305
518
759
1251
69
69
99
242
380
684
989
1670
83
87
145
345
575
1075
1720
2750
115
60
75
190
305
518
759
69
6.00
6.90
12.10
16.20
21.30
25.90
32.90
6.10
6.30
7.30
13.30
17.70
23.50
28.50
36.40
6.80
7.30
8.70
15.40
20.60
27.50
33.7
43.6
8.40
6.00
6.90
12.10
16.20
21.30
25.90
6.10
Brass
A2
Gland
20/16
20/16
20
25
32
32
50S
20/16
20/16
20/16
20
25
32
40
50S
20/16
20/16
20S
25
32
40
50S
63S
20S
20/16
20/16
20
25
32
32
20/16
Temperature limits:
-20 to +65°C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
78
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair
individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced
propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
PAS5308 PART 2, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair
individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC outer sheath reduced
propagation. Blue or Black. Flame propagation to BS4066 PT1, BS EN 50265 and IEC 60332-1.
Pt1
CCC Code
Pt2
7112
7113
7114
7115
7116
7117
7149
7150
7151
7152
7153
7154
7185
7186
7187
7188
-
7312
7313
7314
7315
7316
7317
*7349
7350
7351
7352
7353
7354
7385
7386
7387
7388
-
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
2
5
10
20
30
50
2
5
10
20
30
50
2
5
10
20
30
50
Weight
Outside
(Kg/Km) Diameter
(mm)
161
253
408
753
1153
1900
184
299
489
920
1445
2460
242
408
714
1337
2040
3260
11.00
14.20
20.10
26.30
31.30
40.70
11.80
15.30
21.70
28.80
34.50
44.00
13.70
17.80
25.50
33.40
40.4
52.2
Brass
A2
Gland
20S
25
32
40
40
50
20
25
32
40
50S
63S
25
25
32
50S
50
63
Temperature limits:
-20 to +65°C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
79
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective
aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, Polyethylene bedding,
galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame
propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 2 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel
wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066
Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
CCC Code
Pt1
Pt2
7118
7119
7120
7121
7122
7123
7124
7125
7155
7156
7157
7158
7159
7160
7161
7162
7231
7232
7233
7234
7235
7236
7237
7189
7190
7191
7192
7193
7194
7195
7196
7208
7209
7210
7211
7212 7213 7318
7319
7320
7321
7322
7323
7324
7325
7355
7356
7357
7358
7359
7360
7361
7362
7389
7390
7391
7392
7393
7394
7395
7396
7408
7409
7410
7411
7412 7413 Conductor Stranding No. Of Weight Overall Gland
Size
(mm)
Pairs (Kg/Km) Diameter Size
(mm2)
(mm)
(mm)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
16/0.20
1
16/0.20
2
16/0.20
5
16/0.20
10
16/0.20 20
16/0.20 30
16/0.20 50
16/0.201 TRIPLE
24/0.20
1
24/0.20
2
24/0.20
5
24/0.20 10
24/0.20 20
24/0.20 30
24/0.20 50
24/0.201 TRIPLE
1/1.13
1
1/1.13
2
1/1.13
5
1/1.13
10
1/1.13
20
1/1.13
30
1/1.13
50
7/0.53
1
7/0.53
2
7/0.53
5
7/0.53
10
7/0.53
20
7/0.53
30
7/0.53
50
7/0.53 1 TRIPLE
7/0.67
1
7/0.67
2
7/0.67
5
7/0.67
10
7/0.67
20
7/0.67 1 TRIPLE
242
288
535
868
1466
1944
3360
259
270
330
719
1150
1704
2570
4400
288
250
300
560
970
1240
2180
3500
312
397
918
1466
2519
3352
5310
357
395
490
1430
2235
3935
407
10.8
11.7
17.3
22.3
28.5
33.3
41.5
11.0
11.1
12.3
19.2
24.7
30.7
36.9
46.4
11.4
11.8
13.0
19.7
24.3
31.2
36.2
45.7
12.3
13.7
21.5
27.8
35.1
41.9
53.4
12.6
13.1
15.9
26.5
35.1
46.7
13.7
20/16
20S
20
25
32
32
50S
20/16
20/16
20S
20
25
32
40
50S
20S
20/16
20s
20
25
40
50s
50
20S
20S
25
32
40
50S
63S
20S
20S
20
20
40
50
20S
Nylon
Cleat
Size
0.5
0.5
0.7
0.9
1.2
1.4
1.8
0.5
0.5
0.5
0.8
1.0
1.2
1.6
2.0
0.5
0.5
0.6
0.8
1.0
1.4
1.6
2.0
0.5
0.6
0.9
1.1
1.4
1.8
TC9
0.5
0.6
0.6
1.1
1.4
2.0
0.6
Temperature limits:
-20 to +65°C.
*Bending radius:
6 x overall diameter..
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
80
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, each pair
individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, galvanised
steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to
BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, each pair
individually aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, galvanised steel
wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame propagation to BS4066
Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
Pt1
CCC Code
Pt2
Conductor
Size
(mm2)
7130
7131
7132
7133
7134
7135
7167
7168
7169
7170
7171
7172
7201
7202
7203
7204
7205
7206
7330
7331
7332
7333
7334
7335
7367
7368
7369
7370
7371
7372
7401
7402
7403
7404
7405
7406
0.5
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
Stranding No. Of Weight Overall
(mm)
Pairs (Kg/Km) Diameter
(mm)
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
24/0..20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
2
5
10
20
30
50
2
5
10
20
30
50
2
5
10
20
30
50
460
730
1202
1870
2620
4180
518
805
1323
2323
3312
5520
707
1185
1668
2956
3650
5640
16.8
19.90
26.90
34.3
40.5
51.5
16.60
21.00
28.50
36.80
42.90
54.00
19.40
24.40
32.50
41.60
50.8
62.6
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
32
40
50S
50
20
25
32
40
50S
63S
20
25
32
50S
50
63
0.7
0.8
1.1
1.4
1.6
TC9
0.7
0.9
1.2
1.6
1.8
TC9
0.8
1.0
1.4
1.8
TC9
TC10
Temperature limits:
-20 to +65°C.
*Bending radius:
6 x overall diameter.
Core identification:
Part 1 colour code chart on
page 96.
Part 2 colour code chart on
page 97.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
81
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 1 CONSTRUCTION, OVERALL SCREENED LSZH
Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective
aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH)
sheath, Blue or Black, to PAS5308 Part 1, Type 1 LSZH.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Overall
Diameter
(mm)
Brass
A2
Gland
7246
7247
7248
7249
7250
7251
7243
7273
7274
7275
7276
7277
7278
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
1
2
5
10
20
30
1 TRIPLE
1
2
5
10
20
1 TRIPLE
69
99
242
380
684
989
83
87
145
345
575
1075
115
6.30
7.30
13.30
17.70
23.50
28.50
6.8
7.3
8.7
15.4
20.60
27.50
8.40
20/16
20/16
20
25
32
40
20/16
20/16
20S
25
32
40
20S
Temperature limits:
-20 to +65°C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 1 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH
Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair
individually aluminium/mylar tape screened. Complete with 0.5mm2 drain wire, collective
aluminium/mylar tape screen complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH)
outer sheath, Black or Blue, generally to PAS5308 Part 1, Type 1 LSZH.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Overall
Diameter
(mm)
Brass
A2
Gland
72712
72713
72714
72715
72716
71149
71150
71151
71152
7253
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
16/0.2
16/0.2
16/0.2
16/0.2
16/0.2
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
2
5
10
20
30
2
5
10
20
30
161
253
408
753
1153
184
299
489
920
1445
11.00
14.20
20.10
26.30
31.30
11.80
15.30
21.70
28.80
34.50
20S
25
32
40
40
20
25
32
40
50S
Temperature limits:
-20 to +65°C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
82
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 2 CONSTRUCTION, OVERALL SCREENED LSZH
Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, collective aluminium/mylar
foil tape screen, complete with 0.5mm2 drain wire, low smoke zero halogen bedding (LSZH), galvanised steel
wire armour, low smoke zero halogen (LSZH) sheath, Black or Blue, generally to PAS5308 Part 1, Type 2 LSZH.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
72718
72719
7255
7256
7257
7258
7259
7260
7261
72362
7289
7290
7291
7292
7293
7496
7308
7309
7310
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
16/0.2
16/0.2
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.2
24/0.2
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
1
2
1
2
5
10
20
30
50
1 TRIPLE
1
2
5
10
20
1 TRIPLE
1
2
5
Weight
Overall
(Kg/Km) Diameter
(mm)
242
288
270
330
719
1150
1704
2570
4400
288
312
397
918
1466
2519
357
395
490
1430
10.80
11.70
10.70
11.90
18.80
24.30
30.30
36.9
46.4
11.4
11.90
13.30
21.10
27.40
35.50
12.6
13.1
15.9
26.5
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20S
20/16
20S
20
25
32
40
50S
20S
20S
20S
25
32
40
20S
20S
20
20
0.5
0.5
0.5
0.5
0.8
1.0
1.2
1.6
2.0 0.5
0.5
0.6
0.9
1.1
1.4
0.5
0.6
0.6
1.1
Temperature limits:
-20 to +65°C.
*Bending radius:
6 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 2 CONSTRUCTION, INDIVIDUALLY SCREENED LSZH
Plain annealed flexible copper conductors, XLPE insulated, laid up to form pairs, each pair individually
aluminium/mylar foil tape screened, complete with 0.5mm2 drain wire, collective aluminium/mylar foil tape
screen, complete with 0.5mm2 drain wire, low smoke zero halogen (LSZH) bedding, galvanised steel wire
armour, low smoke zero halogen (LSZH) sheath, Blue or Black, generally to PAS5308 Part 1, Type 2 LSZH.
CCC
Code
Conductor
Size
(mm2)
7230
72131
72132
7267
7268
7269
7270
72563
72566
72569
7298
7299
7297
7296
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
Stranding
(mm)
No. Of
Pairs
16/0.2
2
16/0.2
5
16/0.2
10
24/0.20
2
24/0.20
5
24/0.20
10
24/0.20
20
24/0.2
2 TRIPLE
24/0.2
5 TRIPLE
24/0.2 10 TRIPLE
7/0.53
2
7/0.53
5
7/0.53
10
7/0.53
20
Weight
Overall
(Kg/Km) Diameter
(mm)
460
730
1202
518
805
1323
2323
476
670
1456
707
1185
1668
2956
16.80
19.90
26.90
16.60
21.00
28.50
36.80
15.9
17.8
29
19.40
24.40
32.50
41.60
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
32
20
25
32
40
20
20
32
20
25
32
50S
0.7
0.8
1.1
0.7
0.9
1.2
1.6
0.7
0.8
1.2
0.8
1.0
1.4
1.8
Temperature limits:
-20 to +65°C.
*Bending radius:
6 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
83
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 3 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, polyethylene insulated, laid up to form pairs, collective
aluminium/mylar tape screen, complete with 0.5mm2 drain wire, polyethylene bedding, lead
sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame
propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
PAS5308 PART 2, TYPE 3 CONSTRUCTION, OVERALL SCREENED
Plain annealed flexible copper conductors, PVC insulated, laid up to form pairs, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed,
galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black. Flame
propagation to BS4066 Parts 1 and 3, BS EN 50265, BS EN 50266, IEC 60332-1 and IEC 332-3C.
CCC Code
Pt1
Pt2
7821
7822
7823
7824
7825
7826
7827
7971
7972
7973
7974
7975
7976
7977
7851
7852
7853
7854
7855
7856
7857
7921
7922
7923
7924
7925
7926
7927
7951
7952
7953
7954
7955
7956
7957
Conductor Stranding No. Of Weight Overall Gland
Size
(mm)
Pairs (Kg/Km) Diameter Size
(mm2)
(mm)
(mm)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
1
2
5
10
20
30
50
1
2
5
10
20
30
50
1
2
5
10
20
30
50
700
795
1598
2280
3630
4385
6895
710
828
1627
2275
3149
4420
6964
940
1051
1973
2823
4498
6207
8961
15.7
16.8
25.1
29.4
37.3
43.1
53.1
15.8
17.0
25.0
29.6
37.6
42.6
53.5
16.9
19.0
27.4
33.2
42.1
50.1
61.0
20
20
25
32
40
50S
63S
20
20
25
32
40
50S
63S
20
20
32
32
50S
50
63
Nylon
Cleat
Size
0.7
0.7
1.0
1.2
1.6
1.8
TC9
0.7
0.7
1.0
1.2
1.6
1.8
TC9
0.7
0.8
1.1
1.4
1.8
2.0
TC10
Temperature limits:
-20 to +65°C.
*Bending radius:
5 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
84
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles - Pas5308
PAS5308 PART 1, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed copper conductors, polyethylene insulated, laid up to form pairs, each pair
individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, polyethylene bedding, lead
sheathed, galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black.
PAS5308 PART 2, TYPE 3 CONSTRUCTION, INDIVIDUALLY SCREENED
Plain annealed flexible copper conductors, PVC insulated laid up to form pairs, each pair
individually aluminium/mylar foil tape screened complete with 0.5mm2 drain wire, collective
aluminium/mylar foil tape screen complete with 0.5mm2 drain wire, PVC bedding, lead sheathed,
galvanised steel wire armour, PVC outer sheath reduced propagation. Blue or Black.
CCC Code
Pt1
Pt2
7830
7831
7832
7833
7834
7835
N/A
N/A
N/A
N/A
N/A
N/A
7870
7871
7872
7873
7874
7875
7930
7931
7932
7933
7934
7935
N/A
N/A
N/A
N/A
N/A
N/A
7970
7971
7972
7973
7974
7975
Conductor Stranding No. Of Weight Overall Gland
Size
(mm)
Pairs (Kg/Km)Diameter Size
(mm2)
(mm)
(mm)
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
2
5
10
20
30
50
2
5
10
20
30
50
2
5
10
20
30
50
1280
1810
2720
4270
6000
8330
1280
1820
2750
4350
6110
8350
1680
2300
4000
6300
8110
11160
21.5
26.0
32.7
40.9
46.3
58.5
22.3
27.2
34.2
43.8
51.4
62.5
25.5
30.0
40.1
50.2
57.6
70.6
25
25
32
50S
50S
63S
25
25
40
50S
50
63
25
32
50S
50
63S
75S
Nylon
Cleat
Size
0.9
1.1
1.4
1.8
2.0
TC10
0.9
1.1
1.4
1.8
TC9
TC10
1.1
1.2
1.6
2.0
TC10
TC12
Temperature limits:
-20 to +65°C.
*Bending radius:
15 x overall diameter.
Core identification:
Part 1 colour code chart on
page 86.
Part 2 colour code chart on
page 87.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
85
Instrumentation, Control & Communication Cables
INSTRUMENTATION AND CONTROL CABLES PAS5308
PART 1 COLOUR CODING
Pair
Number
A
Wire
B
Wire
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BLACK
BLACK
BLUE
BLACK
BLUE
GREEN
BLACK
BLUE
GREEN
BROWN
BLACK
BLUE
GREEN
BROWN
WHITE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
BLACK
BLUE
GREEN
BROWN
BLUE
GREEN
GREEN
BROWN
BROWN
BROWN
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
ORANGE
YELLOW
YELLOW
YELLOW
YELLOW
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WHITE
RED
ORANGE
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
BLACK
BLUE
GREEN
BROWN
WHITE
RED
ORANGE
YELLOW
GREY
BLACK
BLUE
GREEN
BROWN
WHITE
YELLOW
YELLOW
YELLOW
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
For individual screened pairs, identification will be Black/Blue numbered pairs.
Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue,
Green, Brown.
Single triple will be Blue , Black, Green.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
86
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
INSTRUMENTATION AND CONTROL CABLES PAS5308
PART 2 COLOUR CODING
Pair
Number
A
Wire
B
Wire
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
WHITE/BLUE
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
RED/BLUE
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
BLUE/BLACK
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
YELLOW/BLUE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
WHITE/ORANGE
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED
ORANGE/RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
For individual screened pairs, identification will be White/Blue numbered pairs.
Two pair collectively screened cables are in quad formation colour coded in rotation, Black, Blue,
Green, Brown.
Single triple will be Blue, White, Orange.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
87
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles Bsc
(coRus) standaRd
Plain annealed flexible copper conductors, PVC bedding, tinned annealed copper wire braid screen,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Grey. 300/500 volts grade to British
Steel specification CES 20 part 4, Type 134. Flame propagation to BS EN 50265 and IEC 60332-1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
BSC1342C
BSC1343C
BSC1344C
BSC1347C
BSC13412C
BSC13419C
BSC13427C
BSC13437C
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
2
3
4
7
12
19
27
37
No. Of
Cores
2
3 4 7 12
Weight
Outside
(Kg/Km) Diameter
(mm)
420
452
490
579
906
1091
1562
1872
13.4
13.8
14.4
15.9
19.5
21.5
25.5
28.1
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20S
20S
20
20
25
32
0.6
0.6
0.6
0.7
0.8
0.9
1.1
1.2
Temperature limits:
-20 to +70°C.
*Bending radius:
6 x overall diameter.
Should not be installed at
temperatures below 0°C.
Colour
BROWN
BROWN BROWN RED
RED
vIOLET
19
RED
vIOLET
RED/BLUE
27
RED
vIOLET
RED/YLW
BLUE/ORANGE
37
RED
vIOLET
RED/YLW
BLUE/ORANGE
GRN/GREY
vIOLET/WHT
BLUE
BLUE GREY BLUE
BLUE ORANGE
BLUE
ORANGE
RED/GRN
BLUE
ORANGE
RED/WHT
BLUE/GRN
BLUE
ORANGE
RED/WHITE
BLUE/GRN
BROWN/YLW
RED/GREY
GREEN/YLW
GREEN/YLW GREEN
GREEN
PINK
GREEN
PINK
RED/YLW
GREEN
PINK
RED/BLACK
BLUE/GREY
GREEN
PINK
RED/BLACK
BLUE/GREY
BRN/WHT
BLACK
YELLOW
YELLOW
TURQUOISE
YELLOW
TURQUOISE
RED/WHT
YELLOW
TURQUOISE
RED/BROWN
GRN/YLW
YELLOW
TURQUOISE
RED/BROWN
GREEN/YLW
BRN/BLACK
WHITE
WHITE
GREY
WHITE
GREY
RED/BLACK
WHITE
GREY
BLUE/YLW
GRN/WHT
WHITE
GREY
BLUE/YLW
GRN/WHT
BROWN/GREY
BLACK
BLACK
BROWN
BROWN
BLACK
BROWN
RED/BROWN
BLACK
RED/BLUE
BLUE/WHE
GRN/BLACK
BLACK
RED/BLUE
BLUE/WHT
GRN/BLACK
vIOLET/YLW
BLUE/YLW
BROWN
RED/GRN
BLUE/BLACK
BROWN
RED/GRN
BLUE/BLACK
GRN/ORANGE
vIOLET/BLACK
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
88
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
instRuMentation and contRol caBles Bsc
(coRus) standaRd
Tinned annealed flexible copper conductors, PVC insulated and laid up to form pairs, collective
aluminium/mylar foil tape screen, complete with 0.5mm2 drain wire, PVC bedding, galvanised steel
wire armour, PVC outer sheath. Orange. 300/500 volts grade. Type 143. Flame propagation to
BS EN 50265 and IEC 60332-1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
BSC1431P
BSC1432P
BSC1435P
BSC14310P
BSC14320P
BSC14330P
BSC14350P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
1
2
5
10
20
30
50
Weight
Outside
(Kg/Km) Diameter
(mm)
260
320
672
1112
1665
2525
4137
10.70
11.90
18.80
24.30
30.30
36.5
46
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20S
20
25
32
40
50
0.5
0.5
0.8
1.0
1.2
1.6
2.0
Temperature limits:
-20 to +70°C.
*Bending radius:
6 x overall diameter.
Should not be installed at
temperatures below 0°C.
CORE IDENTIFICATION ACCORDING TO ENATS 09-6 SECTION 3
Pair
Number
1
A
Wire
BLACK
B
Wire
BLUE
Pair
Number
26
A
Wire
WHITE
B
Wire
YELLOW
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
vIOLET
RED
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
vIOLET
RED
YELLOW
vIOLET
RED
YELLOW
vIOLET
GREY
ORANGE
YELLOW
BROWN
vIOLET
YELLOW
vIOLET
YELLOW
vIOLET
BROWN
vIOLET
vIOLET
BLACK
BLUE
RED
ORANGE
YELLOW
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
89
Instrumentation, Control & Communication Cables
inteRnal telePHone caBles tYPe cW1308
Solid tinned annealed copper conductors, PVC insulated, polyester taped, PVC sheathed. To BPO
CW(M) 1308. Sheath colour: White. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Stranding
(mm)
No. Of
Pairs
Weight
(Kgs/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
13000
13001
13002
13004
13005
13006
13013
13007
13008
13009
13010
13012
13014
13016
13018
13020
13022
13023
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
2
3
4
6
10
10+E
12
15
20+E
25+E
30+E
40+E
50+E
60+E
80+E
100+E
160+E
320+E
18
24
35
47
70
102
80
95
126
163
200
273
365
412
501
687
1135
2306
3.6
4.5
5.8
6.8
8.3
8.6
9.1
9.8
10.7
11.4
12.2
15
17.5
20
22.5
24
30.5
39.5
20/16
20/16
20/16
20/16
20/16
20S
20S
20S
20
20
20
25
25
32
32
32
40
50
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
WHITE/BLUE WHITE/ORANGE
WHITE/GREEN
WHITE/BROWN
WHITE/GREY
RED/BLUE
RED/ORANGE
RED/GREEN
RED/BROWN
RED/GREY
BLACK/BLUE
BLACK/ORANGE
BLACK/GREEN
BLACK/BROWN
BLACK/GREY
YELLOW/BLUE
YELLOW/ORANGE
YELLOW/GREEN
YELLOW/BROWN
YELLOW/GREY
vIOLET/BLUE
vIOLET/ORANGE
vIOLET/GREEN
vIOLET/BROWN
vIOLET/GREY
PINK/BLUE
PINK/ORANGE
PINK/GREEN
PINK/BROWN
PINK/GREY
BLUE/WHITE
ORANGE/WHITE
GREEN/WHITE
BROWN/WHITE
GREY/WHITE
BLUE/RED
ORANGE/RED
GREEN/RED
BROWN/RED
GREY/RED
BLUE/BLACK
ORANGE/BLACK
GREEN/BLACK
BROWN/BLACK
GREY/BLACK
BLUE/YELLOW
ORANGE/YELLOW
GREEN/YELLOW
BROWN/YELLOW
GREY/YELLOW
BLUE/vIOLET
ORANGE/vIOLET
GREEN/vIOLET
BROWN/vIOLET
GREY/vIOLET
BLUE/PINK
ORANGE/PINK
GREEN/PINK
BROWN/PINK
GREY/PINK
E. denotes earth core.
Temperature limits:
-20 to +70°C.
*Bending radius:
5 x overall diameter.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
90
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
coMMunication caBles - telePHone enats 09-6
Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding,
galvanised steel wire armour, PVC outer sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame
propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13050
13051
13052
13053
13054
13055
13056
0.28
0.28
0.28
0.28
0.28
0.28
0.28
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
1/0.6
**2
5
10
20
30
50
100
Weight
Overall
(Kg/Km) Diameter
(mm)
170
238
454
496
697
1243
1825
9
12.07
15.91
17.18
18.1
26.60
29.8
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20S
20
20
20
32
32
0.5
0.6
0.7
0.7
0.8
1.1
1.2
Solid tinned annealed copper conductors, PVC insulated, twisted to form pairs,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 5 Section 3.6. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13081
13083
13084
13085
13086
13087
13088
13089
13090
13091
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
**2
5
10
15
20
25
30
40
50
60
75
100
Weight
Overall
(Kg/Km) Diameter
(mm)
206
333
586
796
939
1245
1400
1686
1952
2183
2342
3613
10.31
14.1
17.38
19.5
22.48
21.3
23.9
28.2
32.87
35
37
41.8
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20
20
25
25
25
32
32
40
40
50S
0.5
0.6
0.7
0.8
0.9
0.9
1.0
1.2
1.4
1.4
1.6
1.8
** 2 pair laid up in quad
formation. Temperature limits:
-20 to +70°C.
*Bending radius: 6 x overall
diameter.
Core identification:
See colour chart on page 94.
Should not be installed at
temperatures below 0°C.
Solid tinned annealed copper conductors, PVC insulated, twisted to
form pairs, collective aluminium/mylar foil tape screen complete with
0.5mm2 drain wire, PVC bedding, galvanised steel wire armour, PVC outer
sheath. Black. To ENATS 09-6: Issue 5 Section 3.6. Flame propagation to
BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13101
13103
13104
13105
13106
13107
13108
13109
13110
-
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
**2
5
10
15
20
25
30
40
50
100
Weight
Overall
(Kg/Km) Diameter
(mm)
213
379
650
805
955
1256
1413
1700
2110
3628
10.4
14
17.8
20
21.7
24.3
25.9
28.6
31.5
42
Gland
Size
(mm)
Nylon
Cleat
Size
20/16
20S
20
20
25
25
25
32
32
50S
0.5
0.6
0.8
0.8
0.9
1.0
1.1
1.2
1.4
1.8
** 2 pair laid up in quad formation.
Temperature limits:
-20 to +70°C.
*Bending radius: 6 x overall
diameter.
Core identification:
See colour chart on page 94.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
91
Instrumentation, Control & Communication Cables
coMMunication caBles - telePHone enats 09-6
Solid plain annealed copper conductors, PVC insulated, twisted to form pairs, PVC bedding, galvanised steel wire armour,
PVC outer sheath. Black. To ENATS 09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13381
13383
13384
13385
13386
13387
13388
13389
13390
13391
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
**2
5
10
15
20
25
30
40
50
100
Weight
Overall
(Kg/Km) Diameter
(mm)
208
353
606
630
854
1159
1266
1549
1923
3000
10.17
13.92
17.49
18.9
21.06
23.2
26.47
28.82
33.5
43.4
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20
20
25
25
32
32
32
50S
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.8
Solid plain annealed copper conductors, PVC insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain wire,
PVC bedding, galvanised steel wire armour, PVC outer sheath. Black. To ENATS
09-6: Issue 6 Section 4.5. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13401
13403
13404
13405
13406
13407
13408
13409
13410
13411
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
1/0.8
**2
5
10
15
20
25
30
40
50
100
Weight
Overall
(Kg/Km) Diameter
(mm)
223
349
599
795
900
1159
1332
1435
1926
3041
10.3
13.74
18.14
19.4
22.34
23.5
25.21
28
31.44
44.7
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20
20
25
25
25
32
32
50S
0.5
0.6
0.8
0.8
0.9
1.0
1.0
1.2
1.4
1.8
**2 pair laid up in quad formation. Temperature limits:
-20 to +70°C.
*Bending radius: 8 x overall
diameter.
Core identification:
See colour chart on page 94.
Should not be installed at
temperatures below 0°C or above 40°C.
Solid tinned annealed copper, polyethylene insulated, low smoke and zero
halogen (LSZH) bedding, galvanised steel wire armour, low smoke and zero
halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13501 13503 13504 13506
13510 13511 0.5 0.5 0.5 0.5 0.5 0.5 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 1/0.8 **2 5 10 20 50 100 Weight
Overall
(Kg/Km) Diameter
(mm)
200 326 598 783 1823 3041 9.5 13.7 17.47 20.7 20.74 41 Gland
Size
(mm)
Nylon
Cleat
Size
20/16 20S 20 25 25 50S 0.6
0.7
0.9
0.9
1.8
Solid plain annealed copper conductors, polyethylene insulated, twisted to form pairs,
collective aluminium/mylar foil tape screen complete with 0.5mm2 drain, wire, low
smoke zero halogen (LSZH) bedding, galvanised steel wire armour, low smoke and
zero halogen (LSZH) sheath. Black. Generally to ENATS 09-6: Issue 6 Section 4.5.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13601
13603
13604
13606
0.5
0.5
0.5
0.5
1/0.8
1/0.8
1/0.8
1/0.8
**2
5
10
20
Weight
Overall
(Kg/Km) Diameter
(mm)
260
328
602
790
10.9
14.33
17.22
20.8
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20
25
0.5
0.6
0.7
0.9
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
92
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
utilitY industRY PVc contRol caBles, enats 09-6
Stranded plain annealed copper conductor, PVC insulated, PVC bedding, galvanised steel wire
armour, PVC outer sheath. Black. 600/1000 volts grade to BS6346 / ENATS 09-6. Flame retardant
to IEC 60332-3-24c.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
6942X2/5ESI
6943X2/5ESI
6944X2/5ESI
6947X2/5/7
6940/12X2/5/7
6940/19X2/5/7
6940/27X2/5/7
6940/37X2/5/7
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
2
3
4
7
12
19
27
37
Weight
Overall Gland Size
(Kg/Km) Diameter
(mm)
(mm)
329
396
423
672
967
1482
1920
2185
12.2
13.5
14.4
17.2
21.3
25.4
29.3
33.1
20S 20S
20
20
25
25
32
40
Nylon
Cleat
Size
0.5
0.6
0.6
0.7
0.9
1.1
1.2
1.4
Temperature limits:
-30 to +70°C
*Bending radius:
6 x Overall Diameter
Core identification:
White numbered cores.
Should not be installed at
temperatures below 0°C or
above 40°C.
coMMunication caBles - telePHone enats 09-6
Solid plain annealed copper conductor, polyethylene insulated, polyethylene bedding, galvanised
steel wire armour, PVC outer sheath. Black. To ENATS 09-6 issue 6 section 3 table 2 - induced
voltage between the pairs up to 15kv.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
13187
13188
-
0.5
0.5
0.5
1/0.8
1/0.8
1/0.8
7
19
37
900
1800
3000
22.5
32.1
41.7
25
32
50S
0.9
1.4
1.8
Temperature limits:
-20 to +70°C.
*Bending radius:
8 x Overall Diameter Core identification:
7 pair: centre - red & yellow.
outer layer - black & violet, orange & grey**, green & brown, orange & blue**, green & brown, orange &
white**.
19 pair: centre - centre and first layer as 7 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white.
37 pair: centre, first and second layer as 19 pair. outer layer - black & violet, odd pairs red & yellow, even pairs green & brown, blue & white.
**denotes carrier pairs.
Should not be installed at temperatures below 0°C or above 40°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
93
Instrumentation, Control & Communication Cables
coRe identiFication accoRdinG to enats 3.6 and 4.5
SECTION 3.6 COLOUR CODING
Pair
Number
A
Wire
B
Wire
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
BLACK
BLACK
BLACK
BLACK
BLACK
BLUE
BLUE
BLUE
BLUE
BLUE
ORANGE
ORANGE
ORANGE
ORANGE
GREEN
GREEN
GREEN
BROWN
BROWN
GREY
BLACK
BLACK
BLACK
BLACK
WHITE
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
ORANGE
GREEN
BROWN
GREY
WHITE
GREEN
BROWN
GREY
WHITE
BROWN
GREY
WHITE
GREY
WHITE
WHITE
RED
YELLOW
vIOLET
RED
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WHITE
WHITE
BLUE
BLUE
BLUE
GREEN
GREEN
GREEN
RED
RED
RED
RED
RED
GREY
GREY
ORANGE
ORANGE
YELLOW
YELLOW
BROWN
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
YELLOW
vIOLET
RED
YELLOW
vIOLET
RED
YELLOW
vIOLET
GREY
ORANGE
YELLOW
BROWN
vIOLET
YELLOW
vIOLET
YELLOW
vIOLET
BROWN
vIOLET
vIOLET
BLACK
BLUE
RED
ORANGE
YELLOW
All two pair cables are in
quad formation and colour
coded in rotation - Blue, Orange, Green, Brown.
SECTION 4.5 COLOUR CODING
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLACK
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
YELLOW
YELLOW
YELLOW
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
Each unit is lapped with coloured
tape for identification as follows
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT10
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
YELLOW
vIOLET
If sub-units are used, binders for
corresponding sub-units shall be the same colour.
All two pair cables are in quad
formation and colour coded in
rotation - White, Red, Blue,
Orange.
For 30 pair cables the formation
will be 3 X 10 pair units
numbered - 1, 2 and 3.
For 40 pair cables the formation
will be 2 X 20 pair units
numbered - 1 and 2.
For 50 pair cables the formation
will be 5 X 10 pair units
numbered - 1, 2 3, 4 and 5.
For 100 pair cables the
formation will be 5 X 20 pair
units numbered - 1, 2, 3, 4 and 5.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
94
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
coMMunication caBles PetRoleuM JellY Filled
Solid plain annealed copper conductors, cellular polyethylene insulated, petroleum jelly filled, PE
outer sheath. Black. To CW1128A. Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
Nylon
Cleat
Size
13030
13031
13032
13034
13035
1/0.50
1/0.50
1/0.50
1/0.50
1/0.50
5
10
20
50
100
48
82
182
317
613
6.83
7.41
11.48
15.5
21.78
20/16
20/16
20
25
32
0.5
0.7
0.9
Solid plain annealed copper conductors, cellular polyethylene insulated,
petroleum jelly filled solid polyethylene bedding, galvanised steel wire
armour, PE outer sheath. Black. To BPO CW 1128A/1198A. (Concentric
construction). Flame propagation to BS4066 PT1 and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13040
13041
13042
13043
13044
0.196
0.196
0.196
0.196
0.196
1/0.5
1/0.5
1/0.5
1/0.5
1/0.5
5
10
20
50
100
Weight
Overall
(Kg/Km) Diameter
(mm)
199
276
461
920
1416
10.63
12.4
16.23
21.66
26.58
Gland
Size
(mm)
Nylon
Cleat
Size
20S
20S
20
25
32
0.5
0.5
0.7
0.9
1.1
Temperature limits:
0 to +40°C maximum continuous
temperature of standard jelly
compound.
Solid plain annealed copper conductors, cellular polyethylene insulated,
petroleum jelly filled, collective aluminium/mylar tape screen,
polyethylene bedding, galvanised steel wire armour, PVC outer sheath.
Black. To BS3573 and CW1128/1198. Flame propagation to BS4066 PT1
and IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13150
13151
13153
13154
0.63
0.63
0.63
0.63
1/0.9
1/0.9
1/0.9
1/0.9
5
10
20
50
Weight
Overall
(Kg/Km) Diameter
(mm)
392
620
1078
2155
16.7
19.9
24.8
34.5
Gland
Size
(mm)
Nylon
Cleat
Size
20
20
25
40
0.7
0.8
1.0
1.6
COLOUR SCHEME FOR BS3573 - UNIT CONSTRUCTION
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
UNIT 1
UNIT 2
UNIT 3
UNIT 4
UNIT 5
UNIT 6
UNIT 7
UNIT 8
UNIT 9
UNIT 10
BLUE
ORANGE
GREEN
BROWN
GREY
WHITE
RED
BLACK
YELLOW
vIOLET
Cables may be manufactured
using 5-pair sub-units coloured
as 1-5 and 6-10.
If sub-units are used binders for
corresponding sub-units shall be
the same colour.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
95
Instrumentation, Control & Communication Cables
deFence standaRd 61-12 contRol caBles
Tinned annealed flexible copper conductors, PVC insulated, non-hygroscopic binder tape, tinned annealed
copper wire braid screen, PVC outer sheath. Black. 440 volts grade. To Ministry of Defence Standard DEF
61-12 (Part 4 for 7/0.2 conductors, Part 5 for 16/0.2 conductors). Flame propagation to BS4066 PT1 and
IEC 332 PT1.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
722C
723C
724C
726C
728C
7212C
7218C
7225C
7236C
7250C
7260C
1622C
1623C
1624C
1626C
1628C
16210C
16212C
16218C
16225C
16236C
16250C
16260C
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.22
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
7/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
2
3
4
6
8
12
18
25
36
50
60
2
3
4
6
8
**10
12
18
25
36
50
60
23
27
32
55
69
83
110
150
200
270
310
69
79
92
120
146
190
198
250
320
450
564
670
4.1
4.3
4.6
5.9
6.0
7.2
8.5
9.8
11.2
13.0
13.8
6.9
7.2
7.7
8.7
8.9
11.8
11.0
12.5
14.6
16.7
18.5
20.3
16
16
16
16
16
16
20
20
20
25
25
16
16
16
20
20
20
20
20
25
25
32
32
Tinned annealed flexible copper conductors, low smoke and zero
halogen (LSZH) insulation, non-hygroscopic binder tape, tinned
annealed copper wire braid screen, low smoke and zero halogen
(LSZH) outer sheath. Black. 440 volt grade. Generally to ministry of
Defence Standard DEF61-12 Part 5 LSF.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
LSF1622C
LSF1623C
LSF1624C
LSF1626C
LSF16212C
LSF16218C
LSF16225C
0.50
0.5
0.5
0.5
0.5
0.5
0.5
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
16/0.20
2
3
4
6
12
18
25
69
79
92
120
198
250
320
6.9
7.2
7.7
8.7
11.0
12.5
14.6
16
16
16
20
20
20
25
** Laid up in a pair
configuration.
Temperature limits:
-55 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification: See colour chart on page 97.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
96
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
DEFENCE STANDARD 61-12 CONTROL CABLES
COLOUR CODING
Core
Number
Colour
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
35
36
RED
BLUE
GREEN
YELLOW
WHITE
BLACK
BROWN
vIOLET
ORANGE
PINK
TURQUOISE
GREY
RED/BLUE
GREEN/RED
YELLOW/RED
WHITE/RED
RED/BLACK
YELLOW/BLUE
YELLOW/BLUE
WHITE/BLUE
BLUE/BLACK
ORANGE/BLUE
GREEN/BLUE
GREY/BLUE
YELLOW/GREEN
WHITE/GREEN
GREEN/BLACK
ORANGE/GREEN
GREY/GREEN
YELLOW/BROWN
WHITE/BROWN
BROWN/BLACK
GREY/BROWN
YELLOW/vIOLET
vIOLET/BLACK
vIOLET/BLACK
WHITE/vIOLET
Where 2 colours are shown
the core is striped e.g.
Red/Blue - the core is striped
Red with Blue.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
97
Instrumentation, Control & Communication Cables
coMPensatinG and tHeRMocouPle caBles
NON-ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs, collective aluminium mylar
foil tape screen, complete with 0.5mm2 drain wire, PVC outer sheath. Thermocouple wires calibrated
to BS4937, ANSI 96.1 and IEC 584.3. Flame propagation to BS4066 PT1 and IEC 332 PT1.
No Of
Pairs
Conductor
Size
(mm2)
Stranding
(mm)
Overall
Diameter
(mm)
Gland
Size
(mm)
Jx
CCC
Code
Kx
CCC
Code
Tx
CCC
Code
7500
Kcb
CCC
Code
(Was Vx)
7530
1
0.75
24/0.20
6.7
20/16
7570
7550
2
5
10
20
0.75
0.75
0.75
0.75
24/0.20
24/0.20
24/0.20
24/0.20
7.7
13.7
18.1
23.9
20/16
25
25
32
7501
7503
7505
7507
7531
7533
7537
7539
7571
7573
7575
7577
7551
7553
7557
7559
Temperature limits:
-30 to +105°C.
*Bending radius:
5 x overall diameter.
Core identification:
See colour chart on page 99.
Should not be installed at
temperatures below 0°C.
ARMOURED
Plain annealed flexible conductors, PVC insulated, laid up to form pairs,
collective aluminium mylar foil tape screen, complete with 0.5mm2 drain
wire, PVC bedding, galvanised steel wire armour, PVC outer sheath.
Thermocouple wires calibrated to BS4937, ANSI 96.1 and IEC 584.3.
Flame propagation to BS4066 PT1 and IEC 332 PT1.
No Of
Pairs
Conductor
Size
(mm2)
Stranding
(mm)
Overall
Diameter
(mm)
Gland
Size
(mm)
Jx
CCC
Code
Kcb
CCC
Code
(Was Vx)
Kx
CCC
Code
Tx
CCC
Code
1
2
5
10
20
0.75
0.75
0.75
0.75
0.75
24/0.20
24/0.20
24/0.20
24/0.20
24/0.20
11.1
12.3
19.2
24.7
30.7
20/16
20/16
20
25
32
7600
7601
7603
7605
7607
7640
7641
7643
7645
7647
7700
7701
7703
7705
7707
7660
7661
7663
7665
7667
Temperature limits:
-30 to +105°C.
*Bending radius:
6 x overall diameter.
Core identification: See colour chart on page 99.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
98
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
coMPensatinG and tHeRMocouPle caBles
COLOUR CODING
EX
JX
KX
+-
+-
+-
NX
TX
UX
VX
+-
+-
+-
+-
CODE
BRITISH
BS1843: 1952
+-
+-
+-
+-
+-
+-
+-
AMERICAN
ANSI
+-
+-
+-
+-
+-
GERMAN
DIN
+-
+-
+-
+-
RC/SC
KCB
+-
+-
IEC 584-3
+-
+-
+-
+-
+-
+-
IEC 584-3
INTRINSICALLY SAFE
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
99
Instrumentation, Control & Communication Cables
tRaFFic siGnallinG caBles
TRAFFIC CONTROL CABLE WITH ARMOUR
Plain annealed solid copper conductors, PVC insulated, PVC bedding, galvanised steel wire armour,
PVC outer sheath, colour orange, generally to BS6346/87
CCC
Code
Conductor
Size
(mm2)
TRAF4X1
TRAF8X1
TRAF12X1
TRAF16X1
TRAF20X1
TRAF4X1/5
TRAF8X1/5
TRAF12X1/5
TRAF16X1/5
TRAF20X1/5
TRAF8X1ESWA*
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.0
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
1/1.13
1/1.13
1/1.13
1/1.13
1/1.13
1/1.38
1/1.38
1/1.38
1/1.38
1/1.38
1/1.13
4
8
12
16
20
4
8
12
16
20
8
325
413
567
774
905
363
534
704
836
1040
533
13.3
15.6
17.9
19.9
22.0
12.5
15.8
18.5
20.0
21.5
16.3
20S
20S
20
20
25
20S
20
20
20
25
20
Temperature limits:
-15 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
4 core - Red, Blue, Yellow, Green.
8 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange. * includes additional 6mm2 integral
earth conductor.
12 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue violet.
16 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red.
20 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red, violet/Red, Orange/Red,
Green/Red, Blue/White.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
100
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Instrumentation, Control & Communication Cables
tRaFFic siGnallinG caBles
TRAFFIC CONTROL CABLE NON ARMOURED
Plain annealed solid copper conductors, PVC insulated, PVC sheathed, colour orange, generally
to BS6346/87, 600/1000v grade.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Brass
A2
Gland
TRAF8X1NA
TRAF12X1NA
TRAF8X1E*
1.0
1.0
1.0
1/1.13
1/1.13
1/1.13
8
12
8
218
305
523
12.6
13.5
14.49
20
25
25
Temperature limits:
-15 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
4 core - Red, Blue, Yellow, Green.
8 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange. * includes additional 6mm2 integral
earth conductor.
12 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue violet.
16 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red.
20 core - Brown, Yellow, Green, Red,
White, Blue, Black, Orange,
Red/White, Grey, Red/Blue, violet,
Brown/Red, Yellow/Red, Grey/Red,
Black/Red, violet/Red, Orange/Red,
Green/Red, Blue/White.
Should not be installed at
temperatures below 0°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
101
Instrumentation, Control & Communication Cables
tRaFFic siGnallinG caBles
LOOP FEEDER CABLE NON ARMOURED
Plain annealed solid copper conductors, polyethylene insulated, polyethylene outer sheath, colour
orange, 600/1000v grade.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
LOOP2X1/5
LOOP4X1/5
LOOP2X2/5
LOOP4X2/5
1.5
1.5
2.5
2.5
1/1.38
1/1.38
1/1.78
1/1.78
2 (1pr)
4 (2pr)
2 (1pr)
4 (2pr)
80
123
110
180
9.0
9.1
9.3
10.7
20S
20S
20S
20S
LOOP FEEDER CABLE ARMOURED
Plain annealed solid copper conductors, polyethylene insulated,
polyethylene bedding, galvanised steel wire armour, polyethylene
outer sheath. Generally to BS6346/87. Outer sheath colour: Orange.
600/1000 volts grade.
CCC
Code
Conductor
Size
(mm2)
LOOP2X1/5SWA
LOOP4X1/5SWA
LOOP2X2/5SWA
LOOP4X2/5SWA
1.5
1.5
2.5
2.5
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
1/1.38
1/1.38
1/1.78
1/1.78
2 (1pr)
4 (2pr)
2 (1pr)
4 (2pr)
235
300
279
383
11.8
12.7
12.5
15.0
20S
20S
20S
20
Temperature limits:
-15 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey,
Blue.
Should not be installed at
temperatures below 0°C.
Temperature limits:
-15 to +70°C.
*Bending radius:
6 x overall diameter.
Core identification:
2 core - Brown, Blue
4 core - Brown, Black, Grey, Blue.
LOOP DETECTOR CABLE
Tinned flexible copper conductor, ethylene propylene rubber
insulated (EPR), polychloroprene sheathed (PCP), 600/100v
generally to BS6500 + BS6195, sheath colour black.
Should not be installed at
temperatures below 0°C.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
(mm)
LOOP1/5
LOOP2/5
1.5
2.5
30/.025
50/0.25
1
1
53.8
64.0
7.0
7.9
20S
20S
Temperature limits:
-30 to +85°C.
*Bending radius: 6 x overall
diameter.
Should not be installed at
temperatures below -25°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
102
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Data Cables
SECTION 9 Data Cables
Data Cables
data, coaXial and lan caBles
BELDEN EQUIvALENTS:
8138/SWA/LSF
8 PAIR 28AWG COLLECTIvE SCREEN PLUS STEEL WIRE ARMOUR,LSF SHEATH.
8471
1 PAIR 16AWG UNSCREENED, PvC SHEATH.
8471/LSF
1 PAIR 16AWG UNSCREENED, PvC SHEATH.
8719
1 PAIR 16AWG COLLECTIvE SCREEN, PvC SHEATH.
8719/LSF
1 PAIR 16AWG COLLECTIvE SCREEN, LSF SHEATH.
8723/LSF
2 PAIR 22AWG INDIvIDUAL SCREEN ,LSOH SHEATH.
8723/SWA/LSF 2 PAIR 22AWG INDIvIDUAL SCREEN PLUS STEEL WIRE ARMOUR, LSF SHEATH.
8760
1 PAIR 18AWG COLLECTIvE SCREEN. PvC SHEATH.
8760/LSF
1 PAIR 18AWG COLLECTIvE SCREEN. LSOH SHEATH.
8761
1 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH.
8761/LSF
1 PAIR 22AWG INDIvIDUAL SCREEN, LSOH SHEATH.
8762
1 PAIR 20AWG COLLECTIvE SCREEN, PvC SHEATH.
8762/LSF
1 PAIR 20AWG COLLECTIvE SCREEN, LSOH SHEATH.
8777
3 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH.
8778
6 PAIR 22AWG INDIvIDUAL SCREEN, PvC SHEATH.
9182
1 PAIR 22AWG COLLECTIvE SCREEN, PvC SHEATH.
9463
TWIN AXIAL 20AWG, PvC SHEATH.
9463/SWA/PvC TWIN AXIAL 20AWG PLUS STEEL WIRE ARMOUR, PvC SHEATH.
9501
1 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH.
9501/LSF
1 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9502
2 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH.
9502/LSF
2 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9503
3 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH.
9503LSF
3 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9504
4 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH.
9504LSF
4 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9505LSF
5 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9506
6 PAIR 24AWG COLLECTIvE SCREEN, PvC SHEATH.
9506LSF
6 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9729
2 PAIR 24AWG INDIvIDUAL SCREEN, PvC SHEATH.
9773
3 PAIR 18AWG INDIvIDUAL SCREEN, PvC SHEATH.
9841LSF
1 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
9842LSF
2 PAIR 24AWG COLLECTIvE SCREEN, LSOH SHEATH.
COAXIAL CABLES
CT100
CT100LSOH
CCF100BK
CC100BK
CCF125BR
CT125
CT125LSOH
CT125BR
CT125RBS
CT167
CT167RBS
RG11AU
RG11SWA
RG58
RG59BU
RG59LSOH
RG59SWA
RG62AU
RG62SWA
URM202
URM203
URM70
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, PE DIELECTRIC, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, LSOH SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, AIR SPACED, DIRECT BURIAL SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, PvC SHEATH.
75 OHM DOUBLE SCREENED, LOW LOSS COAX, FOAM FILLED, DIRECT BURIAL SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PvC SHEATH.
50 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, LSOH SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC PLUS STEEL WIRE ARMOUR, PvC SHEATH.
93 OHM BRAIDED SCREEN, PE TUBE AND THREAD, PvC SHEATH.
93 OHM BRAIDED SCREEN, PE TUBE AND THREAD PLUS SWA, PvC SHEATH.
75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PvC SHEATH.
75 OHM BRAIDED SCREEN, CELLULAR PE DIALECTRIC, PvC SHEATH.
75 OHM BRAIDED SCREEN, SOLID PE DIELECTRIC, PvC SHEATH.
UTP CABLES
4UTPCAT5E
4UTPCAT5EBU
4UTPCAT5ELSF
4FTPCAT5E
4FTPCAT5ELSF
4UTPCAT5EDUCT
4FTPCAT5EDUCT
4FTPCAT5ESWA
4UTPCAT6
4UTPCAT6LSF
ENHANCED UNSCREENED 4 PAIR CAT 5 E, GREY PvC SHEATH.
ENHANCED UNSCREENED 4 PAIR CAT 5 E, BLUE PvC SHEATH.
ENHANCED UNSCREENED 4 PAIR CAT 5 E, LSF vIOLET SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, GREY PvC SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, LSF vIOLET SHEATH.
ENHANCED UNSCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E, DUCT GRADE SHEATH.
ENHANCED SCREENED 4 PAIR CAT 5 E PLUS SWA, LSF BLACK SHEATH.
UNSCREENED 4 PAIR CAT 6, GREY PvC SHEATH.
UNSCREENED 4 PAIR CAT 6, LSF vIOLET SHEATH.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
104
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Railway Cables
SECTION 10 Railway Cables
Railway Cables
RailWaY siGnallinG caBles
Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3 for types B1, LSZH
insulated for types A1, A2, A3. Heavy duty PCP RS2 sheath for types A1 & B1, LSZH sheath for types A2 &
A3. Manufactured to Network Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005).
CCC
Code
A11X/75BR
A11X/75RD
A11X/75OR
A11X/75GY
A11X/75vIR
A11X/75BK
A11X115BK
A21X/75
A21X115
A32X/75
A34X/75
A36X/75
A310X/75
A314X/75
A336X/75
A348X/75
B11X2/5
B11X10
B11X35
B22X1/5
B22X2/5
B22X10
B22X16
B22X35
B22X70
B22X95
B24X/75
B24X1/5
B24X2/5
B24X10 B27X/75
B27X1/5
B27X2/5
B210X/75
B210X1/5
B210X2/5
B212X/75
B26PX/75
B212X1/5
B212X2/5
B219X/75
B219X1/5
B219X2/5
B227X/75
B227X1/5
B227X2/5
B237X/75
B237X1/5
B237X2/5
B248X/75
B248X1/5
B248X2/5
Rail
Code
Rail
Type
Conductor Stranding No. Of Weight Overall Gland
Size
(mm)
Cores (Kg/Km) Diameter Size
(mm)
(mm2)
6/120002 A1 Brown
6/120003
A1 Red
6/120004 A1 Orange
6/120005
A1 Grey
6/120006 A1 violet
6/120007 A1 Black
6/120008 A1 Black
6/120020
A2
6/120024
A2
6/120040
A3
6/120041
A3
6/120042
A3
6/120043
A3
6/120044
A3
6/120045
A3
6/120046
A3
6/120061
B1
6/120062
B1
6/120063
B1
6/120081
B2
6/120082
B2
6/120083
B2
6/120113
B2
6/120084
B2
6/120085
B2
6/120086
B2
6/120087
B2
6/120088
B2
6/120089
B2
B2
6/120090
B2
6/120091
B2
6/120092
B2
6/120093
B2
6/120094
B2
6/120095
B2
6/120096
B2
6/120111
B2
6/120097
B2
6/120098
B2
6/120099
B2
6/120100
B2
6/120101
B2
6/120102
B2
6/120103
B2
6/120104
B2
6/120105
B2
6/120106
B2
6/120107
B2
6/120108
B2
6/120109
B2
6/120110
B2
0.75
0.75
0.75
0.75
0.75
0.75
1.15
0.75
1.15
0.75
0.75
0.75
0.75
0.75
0.75
0.75
2.5
10
35
1.5
2.5
10
16
35
70
95
0.75
1.5
2.5
10
0.75
1.5
2.5
0.75
1.5
2.5
0.75
0.75
1.5
2.5
0.75
1.5
2.5
0.75
1.5
2.5
0.75
1.5
2.5
0.75
1.5
2.5
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
16/0.30
7/0.37
16/0.30
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.37
7/0.67
7/1.35
19/1.53
7/0.53
7/0.67
7/1.35
7/1.70
19/1.53
19/2.14
19/2.52
7/0.37
7/0.53
7/0.67
7/1.35
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
7/0.37
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
1
1
1
1
1
1
1
1
1
2
4
6
10
14
36
48
1
1
1
2
2
2
2
2
2
2
4
4
4
4
7
7
7
10
10
10
12
6pr
12
12
19
19
19
27
27
27
37
37
37
48
48
48
16
16
16
16
16
16
20
30
35
67
108
160
259
495
752
963
34
205
495
135
170
443
625
1232
2043
2945
150
220
295
675
225
370
500
280
401
680
321
469
410
730
425
615
815
606
897
1200
786
1126
1600
972
1280
1960
2.95
N/A
2.95
N/A
2.95
N/A
2.95
N/A
2.95
N/A
2.95
N/A
3.25
N/A
4.50
N/A
4.80 20/16
7.75 20/16
9.20
20S
11.10
20S
14.35
25
15.75
25
24.20
32
27.50
40
8.05 20/16
10.60 20S
14.50
25
10.75
20S
11.80
20
16.85
25
18.80
25
25.05
32
64.80
75
74.70
90
11.50
20S
12.30
20
13.35
20
19.0
32
13.25
20
14.20
25
15.50
25
16.20
25
17.50
25
19.20
25
16.65
25
22.15
32
18.00
25
19.80
25
19.15
25
20.80
32
22.95
32
22.60
32
25.00
32
27.65
40
22.60
32
28.25
40
31.25
40
28.95
40
31.60
40
35.10
50S
Temperature limits:
-25 to +85°C.
*Bending radius:
8 x overall diameter.
Core identification:
Black with white numbers.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
106
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Railway Cables
RailWaY siGnallinG caBles
Stranded or flexible tinned copper conductors to BS6360, EPR insulated to BS7655-3.2. Heavy duty
PCP RS2 sheath for types C1 + C2, LSZH sheath for types D1, D2, E1+E2. Manufactured to Network
Rail specification NR/PS/SIG/00005 (formerly RT/E/PS/00005).
CCC
Code
Rail
Code
C11X2/5
6/120130
C22X2/5 6/120140
C24X2/5
6/120141
C27X2/5 6/120142
C210X2/5 6/120143
C212X2/5 6/120144
C216X2/5 6/120145
D11X/75
6/120211
D11X1/5
6/120212
D11X2/5
6/120213
D11X10
6/120214
D11X35
6/120215
D22X1/5
6/120216
D22X2/5
6/120217
D22X10
6/120218
D22X16 6/1220226
D22X35
6/120219
D24X1/5 6/120223
D27X1/5 6/120228
D210X1/5 6/120231
D212X1/5 6/120234
D219X1/5 6/120237
D227X/75 6/120238
D227X1/5 6/120239
D227X2/5 6/120240
D237X/75 6/120241
D237X1/5 6/120242
D237X2/5 6/120243
D248X/75 6/120244
D248X1/5 6/120245
D248X2/5 6/120246
E11X2/5
6/120172
E22X2/5
6/120170
E24X2/5
6/120171
E27X2/5
6/120173
E210X2/5 6/120174
E212X2/5 6/120175
Rail
Type
C1
C2
C2
C2
C2
C2
C2
D1
D1
D1
D1
D1
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
D2
E1
E2
E2
E2
E2
E2
Conductor Stranding
Size
(mm)
(mm2)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
0.75
1.5
2.5
10
35
1.5
2.5
10
16
35
1.5
1.5
1.5
1.5
1.5
0.75
1.5
2.5
0.75
1.5
2.5
0.75
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
7/0.37
7/0.53
7/0.67
7/1.35
19/1.53
7/0.53
7/0.67
7/1.35
7/1.70
19/1.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
7/0.37
7/0.53
7/0.67
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
50/0.25
No. Of Weight
Cores (Kg/Km)
1
2
4
7
10
12
16
1
1
1
1
1
2
2
2
2
2
4
7
10
12
19
27
27
27
37
37
37
48
48
48
1
2
4
7
10
12
174
342
445
590
784
868
980
25
30
34
205
495
135
170
443
625.0
1232
200.0
370.0
401.0
410.0
615.0
606
897
1200
786
1126
1600
972
1280
1960
174
342
445
590
784
868
Overall Gland
Diameter Size
(mm)
12.60
25
16.85
25
18.65
25
42.40 50
25.55 40
26.25 40
28.65 40
7.30 20/16
7.65 20/16
8.05 20/16
10.60 20S
14.50
25
10.75 20S
11.80
20
16.85
25
20.9
32
25.05 40
13.2
25
15.8
25
19.4
32
17.3
32
23.1
32
22.60 32
25.00 32
27.65 40
25.55
32
28.25 40
31.25
40
28.95 40
31.60 40
35.10 50S
12.60
20
16.85
25
18.65
25
21.20
32
25.55
32
26.25 40
Temperature limits:
-25 to +85°C.
*Bending radius:
8 x overall diameter.
Core identification:
Black with white numbers.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
107
Railway Cables
RailWaY tRain PRotection WaRninG caBles
Flexible tinned copper conductors to BS6360, EPR insulated to BS7655-2.3, separate drain
wire,single aluminium tape screen (polyester backed). Black Heavy duty PCP RS2 sheath to BS7655
for type C3, LSZH sheath for type E3. Manufactured to Network Rail specification
NR/PS/SIG/OOOO5 (formerly RT/E/PS/00005).
CCC
Code
Rail
Code
Rail
Type
Conductor Stranding
Size
(mm)
(mm2)
C3TPWS
E3TPWS
6/160086
6/160090
C3TPWS
E3TPWS
2.5
2.5
50/0.25
50/0.25
No. Of Weight
Overall Gland
Cores (Kg/Km) Diameter Size
(mm)
1PR
1PR
250
250
17.50
17.50
25
25
Temperature limits:
-25 to +85°C.
*Bending radius:
8 x overall diameter.
RailWaY Point HeateR caBles
Flexible tinned copper conductor to B6360, EPR insulation type GP4 to BS7655, black PCP type
EM2 sheath to BS7655. Manufactured to Network Rail specification NR/SP/ELP/40045 (formerly
R/E/PS/40045).
CCC
Code
Rail
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
3184PH1/5
3188PH1/5
3188PH2/5
6388PH4
6388PH6
6388PH10
6388PH16
6/150002
6/153002
6/153103
-
1.5
1.5
2.5
4.0
6.0
10.0
16.0
30/0.25
30/0.25
50/0.25
56/0.30
84/0.30
75/0.40
118/0.40
4
8
8
8
8
8
8
Weight
Overall
(Kg/Km) Diameter
(mm)
220
460
510
830
1040
1799
2480
14.32
18.44
23.36
23.60
25.60
31.70
36.20
Gland
Size
25
25
32
32
32
40
50S
Temperature limits:
-30 to +70°C.
Core identification:
4 core - Yellow, Yellow, Blue, Blue.
8 core - Yellow, Yellow, Blue, Blue,
Brown, Brown, Black, Black.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
108
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Railway Cables
RailWaY aXle countinG caBles
Solid plain annealed copper conductors, polyethylene insulation, petroleum jelly filled, polyethylene
outer sheath. Manufactured to Network Rail specification RT/E/PS/0031.
CCC
Code
Rail
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
F1D0902
F1D0910
F1D0912
F1D0919
F1D0924
F1D1402
F1D1410
F1D1412
F1D1419
F1D1424
6/170001
6/170002
6/170003
6/170004
6/170005
6/170121
6/170122
6/170123
6/170124
6/170125
0.63
0.63
0.63
0.63
0.63
1.5
1.5
1.5
1.5
1.5
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/1.4
1/1.4
1/1.4
1/1.4
1/1.4
2
10
12
19
24
2
10
12
19
24
Weight
Overall
(Kg/Km) Diameter
(mm)
165
526
633
1034
1326
318
1020
1691
1691
2419
13.20
21.60
24.80
31.20
33.80
23.40
30.00
32.00
37.30
42.30
Gland
Size
25
32
32
40
50S
32
40
50S
50S
50S
Two pair cables laid up in
quad formation colour coded
in rotation, Orange, White,
Green, Black.
Temperature limits:
-40 to +70°C.
*Bending radius:
15 x overall diameter.
Core identification:
Pair No
A Wire
B Wire
Pair No
A Wire
B Wire
1
2
3
4
5
6
7
8
9
10
11
12
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
YELLOW
YELLOW
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
13
14
15
16
17
18
19
20
21
22
23
24
YELLOW
YELLOW
YELLOW
vIOLET
vIOLET
vIOLET
vIOLET
vIOLET
TURQUOISE
TURQUOISE
TURQUOISE
TURQUOISE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
RailWaY datalinK caBle
Solid copper conductor, polyethylene insulation, aluminium/polyethylene laminated moisture barrier,
polyethylene sheath black or blue. To BR1932.
CCC
Code
Rail
Code
DATALINK2X1/27
DATALINK2X1/27BU
DATALINK2X1/27LSF
6/166065
6/166065
6/166065
Stranding No. Of
(mm)
Cores
1/1.27
1/1.27
1/1.27
2
2
2
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
136
136
136
12.47
12.47
12.47
25
25
25
Temperature limits:
PE sheath -40 to + 70°C.
LSZH sheath -10 to + 50°C.
*Bending radius:
15 x overall diameter.
Core identification:
Blue, Red.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
109
Railway Cables
RailWaY aXle countinG caBle non aRMouRed
Solid tinned annealed copper conductors, polyethylene insulation (type 03 to BS6234), petroleum
jelly filled (XPS and XQS types only), glass fibre weave, aluminium/polymer laminate tape,
polyethylene sheath XPS type (type 03C to BS6234) or LSZH XPZ type. Manufactured to Network
Rail specification RT/E/PS/0031. Spec AzLM axle counter cable NRL2SIG30060.
CCC
Code
Rail
Code
XPS0902
XPS0910
XPS0912
XPS0919
XPS0924
XPS1402
XPS1410
XPS1412
XPS1419
XPS1424
XPZ0902
XPZ0910
XPZ0912
XPZ0919
XPZ0924
XPZ1402
XPZ1410
XPZ1412
XPZ1419
XPZ1419
006/170007
006/170008
006/170009
006/170034
006/170035
006/170036
006/170037
006/170038
006/170039
006/170040
006/170023
006/170024
006/170025
006/170026
006/170027
006/170028
006/170029
006/170030
006/170031
006/170032
Pair
1
2
3
4
5
6
7
8
9
10
11
12
Cable
Type
Conductor Standing
Size
(mm)
(mm2)
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPS
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
XPZ
0.63
0.63
0.63
0.63
0.63
1.5
1.5
1.5
1.5
1.5
0.63
0.63
0.63
0.63
0.63
1.5
1.5
1.5
1.5
1.5
Core Colours
White
White
White
White
White
Red
Red
Red
Red
Red
Yellow
Yellow
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Blue
Orange
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/1.4
1/1.4
1/1.4
1/1.4
1/1.4
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
1/1.4
1/1.4
1/1.4
1/1.4
1/1.4
Pair
13
14
15
16
17
18
19
20
21
22
23
24
No. Of
Pairs
Weight
Overall
(Kg/Km) Diameter
(mm)
2
10
12
19
24
2
10
12
19
24
2
10
12
19
24
2
10
12
19
24
215
530
584
810
982
320
910
1016
1460
1787
200
424
468
632
746
314
807
909
1284
1548
13.8
24.7
26.4
31.4
34.5
16.4
31.4
33.8
40.8
45.0
13.8
24.7
26.4
31.4
34.5
16.4
31.4
33.8
40.8
45.0
Temperature limits:
- 25 to + 85°C.
*Bending radius:
7.5 x overall diameter
Core identification:
Table 6 core colours:
Core Colours
Yellow
Yellow
Yellow
violet
violet
violet
violet
violet
Turquoise
Turquoise
Turquoise
Turquoise
Green
Brown
Grey
Blue
Orange
Green
Brown
Grey
Blue
Orange
Green
Brown
Table 7 layer make-up:
Pair Nos. In Each Layer
NO. OF PAIRSCENTRE
2
1 & 2
10
1 & 2
12
1 -> 3
19
1
24
1 & 2
1ST LAYER
3 -> 10
4 -> 12
2 -> 7
3 -> 10
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
110
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Railway Cables
FiXed telePHone netWoRK (Ftn) coPPeR tRacKside caBles
Solid plain annealed copper conductors to BS6360, polyethylene insulation, petroleum jelly filled,
corrugated steel armour, polyethylene outer sheath. Manufactured to Network Rail specification
NR/PS/TEL/00015 (formerly RT/E/PS/00015).
CCC
Code
Rail
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Pairs
13781
13784
13786
13788
13790
6/168061
6/168063
6/168064
6/168065
6/168066
0.63
0.63
0.63
0.63
0.63
1/0.9
1/0.9
1/0.9
1/0.9
1/0.9
2
10
20
30
50
Pair
Number
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
Weight
Overall
(Kg/Km) Diameter
(mm)
250
520
820
915
1550
19.00
23.80
27.60
30.9
35.70
Gland
Size
20
25
32
32
32
Temperature limits:
-25 to +85°C.
Core identification:
2 PAIR (laid up in quad
formation).
Bending radius:
10 x overall diameter.
20 PAIR (laid up in 4x5 pair)
PAIR
NUMBER
Sub-Unit (Code A)
A
WIRE
B
WIRE
Pair
Number
Sub-Unit (Code B)
A
Wire
B
Wire
1
2
3
4
5
WHITE
WHITE
WHITE
WHITE
WHITE
BLUE
ORANGE
GREEN
BROWN
GREY
1
2
3
4
5
RED
RED
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
Each unit is lapped with coloured tape for identification as follows:
Unit
Number
Unit
Code
Colour Of
Bindings
1
2
3
4
A
B
C
D
BLUE
BLUE
ORANGE
ORANGE
30 PAIR (laid up in 3x10 pair)
50 PAIR (laid up in 5x10 pair)
Each unit is lapped with coloured
tape for identification as follows:
Pair
Number
Sub-Unit (Code A)
A
Wire
B
Wire
1
2
3
4
5
6
7
8
9
10
WHITE
WHITE
WHITE
WHITE
WHITE
RED
RED
RED
RED
RED
BLUE
ORANGE
GREEN
BROWN
GREY
BLUE
ORANGE
GREEN
BROWN
GREY
UNIT
NUMBER
1
2
3
4
5
COLOUR OF BINDINGS
BLUE
ORANGE
GREEN
BROWN
GREY
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
111
Railway Cables
RailWaY PoWeR and tRacK FeedeR caBles
POWER CABLES
Solid plain aluminium sectoral conductors XLPE insulated, PVC outer sheath, Black to BR880
06/142639. 600/1000 volts grade to BS 5467.
CCC
Code
Rail
Code
SAC2X16NA 6/142419
SAC2X25NA 6/142519
SAC2X35NA 6/142609
SAC2X50NA 6/142629
SAC2X70NA 6/142639
SAC2X95NA 6/142644
SAC4X70NA 6/151469
Conductor
Size
(mm2)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
Gland
Size
16
25
35
50
70
95
70
2
2
2
2
2
2
4
420
455
525
620
840
1020
1750
14.30
16.60
18.00
20.40
22.80
26.20
30.60
25
25
25
32
32
40
40
Temperature limits:
+90°C.
*Bending radius:
8 x overall diameter.
Core identification:
2 core - Brown, Blue.
4 core - Blue, Brown, Black, Grey.
TRACK FEEDER CABLES
Uncompacted circular stranded aluminium to BS6360 or uncompacted. Circular stranded tinned
copper to BS6360. CSP sheathed type RS4 to BS6899, black. Manufactured to Network Rail
specification NR/PS/ELP/21101 (formerly RT/E/S/21101).
CCC
Code
Rail
Code
TRACK150
TRACK161
TRACK240
TRACK500
TRACK500CU
TRACK630CU
TRACK800
TRACK1000
TRACK240LSF
TRACK800LSF
TRACK1000LSF
6/116601
6/132340
6/132990
6/132840
6/132992
6/116612
6/132991
6/116610
-
Polarity Conductor Stranding No. Of
Size
(mm)
Cores
(mm2)
NEGATIvE
NEGATIvE
NEGATIvE
POSITIvE
NEGATIvE
POSITIvE
NEGATIvE
POSITIvE
NEGATIvE
NEGATIvE
POSITIvE
150 AL
161 CU
240 AL
500 AL
500 CU
630 CU
800 AL
1000 AL
240 AL
800 AL
1000 AL
37/2.25
91/1.53
61/2.25
61/3.20
91/2.65
127/2.52
127/2.85
127/3.20
61/2.25
127/2.85
127/3.2
1
1
1
1
1
1
1
1
1
1
1
Weight
Overall Gland
(Kg/Km) Diameter Size
(mm)
540
1887
1076
2245
5291
6692
3255
3943
1076
3255
3943
19.40
24.80
28.30
40.20
40.60
44.20
48.50
53.00
28.3
48.5
53.0
25
32
40
50
50
63S
63S
63
40
63S
63
Temperature limits:
-25°C to +85°C.
*Bending radius:
Aluminium conductor - 10x
overall diameter.
Copper conductor - 8x overall
diameter.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
112
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
SECTION 11 Marine And Offshore Cables
Marine And Offshore Cables UKOOA Cable Identifier
G
n
F 02
1st Character - Fire Performance/voltage Rating
2nd Character - Cable Construction
3rd Character - No. of Cores, Pairs, Trips or Quads
4th & 5th Characters - Conductor Cross Sectional Areas
1st character
F
G
H
J
K
L
Fire resistant, reduced halogen
Fire resistant, LSF Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, LSF Flame retardant, reduced halogen 150/250v
150/250v
8.7/15kv
150/250v
150/250v
600/1000v
M
N
P
W
X
Y
Flame retardant, reduced halogen
Flame retardant, reduced halogen
Flame retardant, reduced halogen
Flame retardant, LSF
Flame retardant, reduced halogen
Flame resistant, low smoke and fume
3.8/6.6kv
1.9/3.3kv
6.35/11kv
600/1000v
600/1000v
600/1000v
2nd character
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Y
Basic construction
Flame retardant
Flame retardant
Fire resistant
Fire resistant
Flame retardant
Flame retardant
Flame retardant
Flame retardant
Flame retardant
Flame retardant
Fire resistant
Fire resistant
Fire resistant
Fire resistant
Flame retardant
Sheath colour
Black (600/1000v), Red (Hv)
Black (600/1000v), Red (Hv)
Black (600/1000v)
Black (600/1000v)
Green/Yellow
Black
Light Blue
Light Blue
Grey
Grey
Light Blue
Light Blue
Grey
Grey
Orange
Armour
Bronze braid
GSWB
Bronze braid
GSWB
None
None
GSWB
GSWB
GSWB
GSWB
GSWB
GSWB
GSWB
GSWB
GSWB
Screen
See Note 2
See Note 2
See Note 2
See Note 2
None
None
Collective
Individual
Collective
Individual
Collective
Individual
Collective
Individual
Co-axial
Single Core
2 Core 3 Core 4 Core 7 Core 12 Core
B
C
D
F
H
J
19 Core
27 Core 37 Core 1 Pair 3 Pair 7 Pair
K
L
M
N
R
S
12 Pair
20 Pair 27 Pair 37 Pair 1 Triple
3 Triple
T
U
X
Y
Z
2 Triple
12 Triple
1 Quad 3 Quad
7 Quad
4th character
00
01
02
03
04
05
06
10
16
25
35
Notes:
1. Shaded entries signify
non-preferred core sizes
2. Hv Cables above
1.9/3.3Kv rating have tinned
copper tape and semiconducting insulating
screen
Common Types:
600/1000 v
LB** - 658*B
EPR/CSP/GSWB/CSP BLUE
WB** - 658*D
EPR/ZH/GSWB/ZH
XD** - FS 658*B
MT/EPR/ZH/GSWB/CSP
YD** - FS 658*D
MT/EPR/ZH/GSWB/ZH
150/250 v
3rd character
1
2
3
4
7
A
Example given: GNF02
Would be:
G - Fire Resistant LSF N - Fire Resistant, Grey, GSWB, Coll Scr
F - 1 Pair
02 - 1.5mm2
0.75 mm2 Flexible (class 5) stranded tinned copper cores
1.0 mm2 Flexible (class 5) stranded tinned copper cores
1.5 mm2 Flexible (class 5) stranded tinned copper cores
2.5 mm2 Stranded tinned copper cores
4 mm2 Stranded tinned copper cores
4 mm2 Stranded tinned copper cores
6 mm2 Stranded tinned copper cores
10 mm2 Stranded tinned copper cores
16 mm2 Stranded tinned copper cores
25 mm2 Stranded tinned copper cores
35 mm2 Stranded tinned copper cores
50
70
95
OA
OB
OC
OD
OE
OF
OG
OH
50 mm2 Stranded tinned copper cores
70 mm2 Stranded tinned copper cores
95 mm2 Stranded tinned copper cores
120 mm2 Stranded tinned copper cores
150 mm2 Stranded tinned copper cores
185 mm2 Stranded tinned copper cores
240 mm2 Stranded tinned copper cores
300 mm2 Stranded tinned copper cores
400 mm2 Stranded tinned copper cores
500 mm2 Stranded tinned copper cores
630 mm2 Stranded tinned copper cores
JG**
JJ**
FG**
FJ** JH** JK** FM**
FP**
KG** KJ**
GL** GN**
KH**
KK**
GM**
GP**
- EPR/COL/CSP/GSWB/CSP BLUE - EPR/COL/CSP/GSWB/CSP GREY - MT/EPR/ZH/CSP/GSWB/CSP BLUE
- MT/EPR/ZH/CSP/GSWB/CSP GREY - EPR/IND/CSP/GSWB/CSP BLUE - EPR/IND/CSP/GSWB/CSP GREY - MT/EPR/IND/ZH/GSWB/CSP BLUE
- MT/EPR/IND/ZH/GSWB/CSP GREY - EPR/COL/ZH/GSWB/ZH BLUE - EPR/COL/ZH/GSWB/ZH GREY - MT/EPR/COL/ZH/GSBW/ZH BLUE - MT/EPR/COL/ZH/GSBW/ZH GREY - EPR/IND/ZH/GSWB/ZH BLUE - EPR/IND/ZH/GSWB/ZH GREY - MT/EPR/IND/ZH/GSWB/ZH BLUE - MT/EPR/IND/ZH/GSWB/ZH GREY
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
114
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low
smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1,
IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
UKOOA
Code
6571TQ1/5
6572TQ1/5
6573TQ1/5
6574TQ1/5
6575TQ1/5
6576TQ1/5
6577TQ1/5
6578TQ1/5
6570/10TQ1/5
6570/12TQ1/5
6570/19TQ1/5
6570/27TQ1/5
6570/30TQ1/5
6570/37TQ1/5
6571TQ2/5
6572TQ2/5
6573TQ2/5
6574TQ2/5
6575TQ2/5
6576TQ2/5
6577TQ2/5
6578TQ2/5
6570/10TQ2/5
6570/12TQ2/5
6570/19TQ2/5
6570/27TQ2/5
6570/30TQ2/5
6570/37TQ2/5
6571TQ4
6572TQ4
6573TQ4
6574TQ4
6575TQ4
6577TQ4
6571TQ6
6572TQ6
6573TQ6
6574TQ6 1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
7/1.04
7/1.04
7/1.04
7/1.04 1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2
3
4
5
6
7
8
10
12
19
27
30
37
1
2 3
4
5
7
1
2
3
4 49
125
150
180
190
240
275
295
360
440
740
970
1015
1220
63
160
190
240
280
470
355
398
519
650
860
1220
1270
1610
90
240
280
360
425
530
115
305
370
475 5.5
8.9
9.4
10.3
11.0
12.2
12.5
13.3
16.2
16.4
19.3
23.5
24.3
26.0
6.0
9.8
10.4
11.4
12.6
16.9
13.7
15.3
17.7
18.3
21.7
26.3
27.1
29.5
6.9
12.0
12.7
13.9
15.3
17.7
7.5
13.1
13.9
15.4 WF102
WF202
WF302
WF402
WF502
WF702
WFA02
WFB02
WFC02
WFD02
WF103
WF203
WF303
WF403
WF503
WF703
WFA03
WFB03
WFC03
WFD03
WF104
WF204
WF304
WF404
WF504
WF704
WF106
WF206
WF306
WF406
Core identification:
White with Black numbers.
Single cores available in
either Black or Green/Yellow
outer sheath.
Temperature limits:
-15 to +90°C.
*Bending radius:
4 x overall diameter.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
115
Marine And Offshore Cables
MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low
smoke, zero halogen (LSF) SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1,
IEC60332-3-22, IEC60754-1,2 and IEC61034-1,2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
UKOOA
Code
6571TQ10
6572TQ10
6573TQ10
6574TQ10
6571TQ16
6572TQ16
6573TQ16
6574TQ16
6571TQ25
6572TQ25
6573TQ25
6574TQ25
6571TQ35
6572TQ35
6573TQ35
6574TQ35
6571TQ50
6572TQ50
6573TQ50
6574TQ50
6571TQ70
6573TQ70
6574TQ70
6571TQ95
6573TQ95
6574TQ95
6571TQ120
6573TQ120
6571TQ150
6571TQ185
6571TQ240
6571TQ300
6571TQ400
6571TQ500
6571TQ630
10
10
10
10
16
16
16
16 25
25
25
25
35
35
35
35
50
50
50
50
70
70
70
95
95
95
120
120
150
185
240
300
400
500
630
7/1.35
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
3
4
1
3
4
1
3
1
1
1
1
1
1
1
165
470
595
745
230
655
830
1045
380
1090
1340
1680
490
1310
1630
2130
640
1720
2210
2840
870
3080
3950
1150
4060
5170
1440
5130
1770
2200
2780
3450
4400
5600
6910
9.0
16.0
17.2
18.9
10.1
18.3
19.5
21.7
12.4
22.9
24.4
27.1
13.6
25.3
27.1
30.1
15.5
29.0
30.9
34.6
17.5
35.3
39.2
19.6
40.3
45.1
21.4
44.4
23.8
26.3
29.5
32.6
36.7
40.5
44.4
WF110
WF210
WF310
WF410
WF116
WF216
WF316
WF416
WF125
WF225
WF325
WF425
WF135
WF235
WF335
WF435
WF150
WF250
WF350
WF450
WF170
WF370
WF470
WF195
WF395
WF495
WF10A
WF30A
WF10B
WF10C
WF10D
WF10E
WF10F
WF10G
WF10H
Single core cables are
available in Black or
Green/Yellow outer sheath.
Temperature limits:
-15 to +90°C.
*Bending radius:
up to 25mm - 4 x overall
diameter.
above 25mm - 6 x overall
diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
116
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low
smoke, zero halogen bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSF)
SW4 outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22,
IEC60754-1,2 and IEC61034-1,2.
CCC
Code
Conductor
Size
(mm2)
6582TQ1/5
6583TQ1/5
6584TQ1/5
6585TQ1/5
6586TQ1/5
6587TQ1/5
6580/12TQ1/5
6580/19TQ1/5
6580/27TQ1/5
6580/37TQ1/5
6582TQ2/5
6583TQ2/5
6584TQ2/5
6585TQ2/5
6586TQ2/5
6587TQ2/5
6580/12TQ2/5
6580/19TQ2/5
6580/27TQ2/5
6580/37TQ2/5
6582TQ4
6583TQ4
6584TQ4
6585TQ4
6587TQ4
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
4.0
4.0
4.0
4.0
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
UKOOA
Code
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/0.85
7/0.85
7/0.85
2
3
4
5
6
7
12
19
27
37
2
3
4
5
6
7
12
19
27
37
2
3
4
5
7
300
325
395
407
425
525
790
1090
1515
1870
350
400
470
485
550
635
990
1390
1990
2500
480
530
585
700
897
13.3
13.8
15.0
15.2
16.5
17.2
21.7
24.7
29.3
33.2
14.2
15.0
16.1
16.9
18.2
18.5
23.9
27.6
33.2
36.7
16.6
17.3
18.4
20.2
22.7
WB202
WB302
WB402
WB702
WBA02
WBB02
WBC02
WBD02
WB203
WB303
WB403
WB503
WB703
WBA03
WBB03
WBC03
WBD03
WB204
WB304
WB404
WB504
WB704
Temperature limits:
-15 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
117
Marine And Offshore Cables
MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low
smoke, zero halogen bedding, galvanised steel wire braid armour, low smoke, zero halogen (LSF)
outer sheath. Black. 600/1000 volts grade to BS6883, IEC60332-1, IEC60332-3-22, IEC60754-1,2 and
IEC61034-1,2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
UKOOA
Code
6582TQ6
6583TQ6
6584TQ6
6582TQ10
6583TQ10
6584TQ10
6582TQ16
6583TQ16
6584TQ16
6582TQ25
6583TQ25
6584TQ25
6582TQ35
6583TQ35
6584TQ35
6582TQ50
6583TQ50
6584TQ50
6582TQ70
6583TQ70
6584TQ70
6582TQ95
6583TQ95
6584TQ95
6582TQ120
6583TQ120
6584TQ120
6582TQ150
6583TQ150
6584TQ150
6583TQ185
6584TQ185
6583TQ240
6584TQ240
6583TQ300
6584TQ300
6
6
6
10
10
10
16
16
16
25
25
25
35
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
240
240
300
300
7/1.04
7/1.04
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/1.70
19/1.35
19/1.35
19/1.35
19/1.53
19/1.53
19/1.53
19/1.78
19/1.78
19/1.78
19/2.14
19/2.14
19/2.14
37/1.78
37/1.78
37/1.78
37/2.03
37/2.03
37/2.03
37/2.25
37/2.25
37/2.25
37/2.52
37/2.52
61/2.25
61/2.25
61/2.52
61/2.52
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
3
4
3
4
570
635
760
750
930
1080
1020
1190
1450
1500
1800
2500
1810
2400
2880
2510
3000
3670
2940
3980
4840
3813
5290
6310
4692
6480
7770
5634
7700
9400
9550
11520
12300
14840
14850
17938
17.9
18.7
20.1
21.0
22.4
24.0
23.7
24.9
26.9
29.0
30.7
33.6
31.0
34.0
36.2
36.0
38.1
41.0
36.0
42.8
46.1
40.9
48.5
52.6
44.9
52.9
57.4
48.9
57.9
63.1
63.8
69.6
71.5
78.3
78.8
84.9
WB206
WB306
WB406
WB210
WB310
WB410
WB216
WB316
WB416
WB225
WB325
WB425
WB235
WB335
WB435
WB250
WB350
WB450
WB270
WB370
WB470
WB295
WB395
WB495
WB20A
WB30A
WB40A
WB20B
WB30B
WB40B
WB30C
WB40C
WB30D
WB40D
WB30E
WB40E
Temperature limits:
-15 to +90°C.
*Bending radius:
6 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
118
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, ethylene propylene rubber (EPR) insulated, low
smoke, zero halogen bedding tinned phosphor bronze braid armour, low smoke, zero halogen (LSF)
SW4 outer sheath. Black. 600/1000 volts grade to IEC90092-353, IEC60331-21, IEC60332-2,
IEC60332-2-22, IEC60751-2,2 and IEC61034-1,2.
CCC
Code
Conductor
Size
(mm2)
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
(mm)
UKOOA
Code
6591TQ6
6591TQ10
6591TQ16
6591TQ25
6591TQ35
6591TQ50
6591TQ70
6591TQ95
6591TQ120
6591TQ150
6591TQ185
6591TQ240
6591TQ300
6591TQ400
6591TQ500
6591TQ630
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
7/1.04
7/1.35
7/1.70
19/1.35
19/1.53
19/1.78
19/2.14
37/1.78
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
91/2.36
91/2.65
127/2.52
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
245
320
395
565
740
940
1270
1600
1930
2330
3000
3710
4480
5340
6540
8000
11.7
13.4
14.5
17.3
18.4
20.3
22.7
25.0
27.2
29.5
33.1
36.6
40.0
43.9
48.1
52.3
WAB06
WAB10
WAB16
WAB25
WAB35
WAB50
WAB70
WAB95
WABOA
WABOB
WABOC
WABOD
WABOE
WABOF
WABOG
WABOH
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
White.
Should not be installed at
temperatures below -15°C.
FiRe Resistant, ePR insulated BRaided aRMouRed sHiPWiRinG
caBle 1.5MM to0 10MM MaRine and oFFsHoRe caBles
Tinned annealed stranded copper conductors, MICA glass taped, ethylene propylene rubber (EPR)
insulated low smoke, zero halogen (LSF) bedding, galvanised steel wire braid armour, low smoke, zero
halogen (SW4) outer sheath to BS7655-2,6.Black. 600/1000 volts grade to BS7917/6883,
IEC60332-1, IEC60332-3-22, IEC61034-1,2, IEC60754-1,2 and IEC60331-21
CCC
Code
Conductor
Size
(mm2)
6582TQ1/5MGT
6583TQ1/5MGT
6584TQ1/5MGT
6587TQ1/5MGT
6580/12TQ1/5MGT
6580/19TQ1/5MGT
6580/27TQ1/5
6582TQ2/5MGT
6583TQ2/5MGT
6584TQ2/5MGT
6587TQ2/5MGT
6580/12TQ2/5MGT
6580/19TQ2/5MGT
6580/27TQ2/5
6583TQ4MGT
6584TQ4MGT
6583TQ6MGT
6583TQ10MGT
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5 4.0
4.0
6.0
10.0
Stranding
(mm)
No. Of
Cores
Weight
(Kg/Km)
Overall
Diameter
UKOOA
Code
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.67
7/0.85
7/0.85
7/1.04
7/1.35
2
3
4
7
12
19
27
2
3
4
7
12
19
27
3
4
3
3
300
325
395
525
790
1090
1515
350
400
470
635
990
1390
1990
530
585
635
930
13.3
13.8
15.0
17.2
21.7
24.7
29.3
14.2
15.0
16.1
18.5
23.9
27.6
33.2
17.3
18.4
18.7
22.4
YD202
YD302
YD402
YD702
YDA02
YDB02
YDC02
YD203
YF303
YD403
YD703
YDA03
YDB03
TDC03
YD304
YD404
YD306
YD310
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
White with Black numbers.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
119
Marine And Offshore Cables
ePR insulated oVeRall scReened sHiPWiRinG caBle to
Bs6883 and uKooa
Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655: section 1.2
colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape. Collective
screened with aluminium backed polyester tape complete with tinned copper drain wire. Flame
retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering, galvanised
steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen
free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to BS7655 section 2.6.
150/250 volts grade manufactured to BS6883 and UKOOA design flame retardant to IEC60332-1 and
IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2.
CCC
Code
KJH00
KJJ00
KJK00
KJL00
KGH00
KGJ00
KGK00
KGL00
KJS00
KGS00
KJT00
KGT00
KJU00
KGU00
KJH02
KJJ02
KJK02
KJL02
KGH02
KGJ02
KGK02
KGL02
KJS02
KJT02
Conductor
Size
(mm2)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Sheath
Colour
UKOOA
Code
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.50
7/0.50
3
7
12
20
3
7
12
20
3Triple
3Triple
7Triple
7Triple
12Triple
12Triple
3
7
12
20
3
7
12
20
3Triple
7Triple
420
660
1000
1570
420
660
1000
1570
510
510
820
820
1290
1290
520
850
1470
2130
520
850
1470
2130
680
1100
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
GREY
KJH00
KJJ00
KJK00
KJL00
KGH00
KGJ00
KGK00
KGL00
KJS00
KGS00
KJT00
KGT00
KJU00
KGU00
KJH02
KJJ02
KJK02
KJL02
KGH02
KGJ02
KGK02
KGL02
KJS02
KJT02
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
pairs - black , white numbered
triples - black, white, red
numbered.
quad - black, white, red, blue
numbered.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
120
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
ePR insulated indiViduallY scReened sHiPWiRinG caBle to
Bs6883 and uKooa
Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655: section
1.2 colour coded cores twisted to form a pair, triple or quad wrapped with polyester tape.Each pair
individually screened with aluminium backed polyester tape complete with tinned copper drain wire.
Flame retardant halogen free bedding, PET tape and rubberised polyamide tape inner covering,
galvanised steel wire braid armour, PET tape and rubberised polyamide tape over armour, flame
retardant, halogen free, enhanced oil resisting thermosetting compound (LSF) SW4 outer sheath to
BS7655 section 2.6. 150/250 volts grade manufactured to BS6883 and UKOOA design flame retardant
to IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2.
CCC
Code
KKF00
KHF00
KKX00
KHX00
KKH00
KKJ00
KKK00
KKL00
KHH00
KHJ00
KHK00
KHL00
KKF01
KHF01
KKX01
KHX01
KKF02
KKG02
KHF02
KKX02
KHX02
KKH02
KKJ02
KKK02
KKL02
KHH02
KHJ02
KHK02
KHL02
KKF03
Conductor
Size
(mm2)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.00
1.00
1.00
1.00
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
2.50
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Sheath
Colour
UKOOA
Code
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
7/0.4
7/0.4
7/0.4
7/0.4
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
1
1
1Quad
1Quad
3
7
12
20
3
7
12
20
1
1
1Quad
1Quad
1
2
1
1Quad
1Quad
3
7
12
20
3
7
12
20
1
230
230
310
310
430
720
1110
1670
430
720
1110
1670
240
240
340
340
290
370
290
370
370
560
980
1700
2430
560
980
1700
2430
330
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
KKF00
KHF00
KKX00
KHX00
KKH00
KKJ00
KKK00
KKL00
KHH00
KHJ00
KHK00
KHL00
KKF01
KHF01
KKX01
KHX01
KKF02
KKG02
KHF02
KKX02
KHX02
KKH02
KKJ02
KKK02
KKL02
KHH02
KHJ02
KHK02
KHL02
KKF03
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
pairs - black , white numbered
triples - black, white, red
numbered.
quad - black, white, red, blue
numbered.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
121
Marine And Offshore Cables
FiRe Resistant, ePR insulated oVeRall scReened
sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa
Tinned stranded circular copper conductor to BS6360 class 2 EPR, GP4 insulation to BS7655:
section 1.2 Mica glass tape insulation, EPR, GP4 insulation to BS7655: section 1.2 colour coded cores
twisted to form a pair, triple or quad wrapped with polyester tape. Collective screened with
aluminium backed polyester tape complete with tinned copper drain wire. Flame retardant halogen
free bedding, PET tape and rubberised polyamide tape inner covering, galvanised steel wire braid
armour, PET tape and rubberised polyamide tape over armour, flame retardant, halogen free,
enhanced oil resisting thermosetting compound. (LSF) SW4 outer sheath to BS7655 section 2.6.
150/250 volts grade manufactured to BS7917/BS6883 and UKOOA design flame retardant to
IEC60332-1 and IEC60332-3-22. Halogen free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire
resistant to IEC60331-21.
CCC
Code
GNH00
GNJ00
GNK00
GNL00
GLH00
GLJ00
GLK00
GLL00
GNS00
GNT00
GNU00
GLS00
GLT00
GLU00
GNH02
GNJ02
GN(10P)02
GNK02
GNL02
GLH02
GLJ02
GLK02
GLL02
GNS02
GNT02
GNU02
GLS02
GLT02
GLU02
Conductor
Size
(mm2)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Sheath
Colour
UKOOA
Code
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
3
7
12
20
3
7
12
20
3Triple
7Triple
12Triple
3Triple
7Triple
12Triple
3
7
10
12
20
3
7
12
20
3Triple
7Triple
12Triple
3Triple
7Triple
12Triple
450
740
1120
1720
450
740
1120
1720
550
930
1450
550
930
1450
570
920
1380
1560
2260
570
920
1560
2260
690
1180
2020
690
1180
2020
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
GREY
GREY
BLUE
BLUE
BLUE
GREY
GREY
GREY
GREY
GREY
BLUE
BLUE
BLUE
BLUE
GREY
GREY
GREY
BLUE
BLUE
BLUE
GNH00
GNJ00
GNK00
GNL00
GLH00
GLJ00
GLK00
GLL00
GNS00
GNT00
GNU00
GLS00
GLT00
GLU00
GNH02
GNJ02
GN(10P)02
GNK02
GNL02
GLH02
GLJ02
GLK02
GLL02
GNS02
GNT02
GNU02
GLS02
GLT02
GLU02
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
pairs - black , white numbered
triples - black, white, red
numbered.
quad - black, white, red, blue
numbered.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
122
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
Marine And Offshore Cables
FiRe Resistant, ePR insulated indiViduallY scReened
sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa
Tinned stranded circular copper conductor to BS6360 class 2 Mica glass tape insulation, EPR, GP4
insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped
with polyester tape.Each pair individually screened with aluminium backed polyester tape complete
with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised
polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised
polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting
compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to
BS7917/BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen
free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21 IEC60331
(BS7917).
CCC
Code
GPF00
GMF00
GPX00
GMX00
GPH00
GMH00
GPJ00
GMJ00
GPK00
GMK00
GPL00
GML00
GPM00
GMM00
GPR00
GMR00
GPS00
GMS00
GPT00
GMT00
GPU00
GMU00
GPF01
GMF01
GPX01
GMX01
GPH01
GMH01
GPJ01
GMJ01
GPK01
GMK01
GML01
GPL01
GPM01
GMM01
GPR01
Conductor
Size
(mm2)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Sheath
Colour
UKOOA
Code
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
24/0.2
7/0.4
7/0.4
7/0.4
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/0.4
1
1
1Quad
1Quad
3
3
7
7
12
12
20
20
27
27
1Triple
1Triple
3Triple
3Triple
7Triple
7Triple
12Triple
12Triple
1
1
1Quad
1Quad
3
3
7
7
12
12
20
20
27
27
1Triple
260
260
330
330
480
480
800
800
1240
1240
2040
2040
2330
2330
280
280
590
590
990
990
1640
1640
270
270
360
360
520
520
920
920
1540
1540
2450
2450
2690
2690
310
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
BLUE
GREY
GREY
BLUE
GREY
GPF00
GMF00
GPX00
GMX00
GPH00
GMH00
GPJ00
GMJ00
GPK00
GMK00
GPL00
GML00
GPM00
GMM00
GPR00
GMR00
GPS00
GMS00
GPT00
GMT00
GPU00
GMU00
GPF01
GMF01
GPX01
GMX01
GPH01
GMH01
GPJ01
GMJ01
GPK01
GMK01
GML01
GPL01
GPM01
GMM01
GPR01
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
pairs - black , white numbered
triples - black, white, red
numbered.
quad - black, white, red, blue
numbered.
Should not be installed at
temperatures below -15°C.
Table information continued on the next page...
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
123
Marine And Offshore Cables
FiRe Resistant, ePR insulated indiViduallY scReened
sHiPWiRinG caBle to Bs6883, Bs7917 and uKooa
Tinned stranded circular copper conductor to BS6360 class 2 Mica glass tape insulation, EPR, GP4
insulation to BS7655: section 1.2 colour coded cores twisted to form a pair, triple or quad wrapped
with polyester tape.Each pair individually screened with aluminium backed polyester tape complete
with tinned copper drain wire. Flame retardant halogen free bedding, PET tape and rubberised
polyamide tape inner covering, galvanised steel wire braid armour, PET tape and rubberised
polyamide tape over armour, flame retardant, halogen free, enhanced oil resisting thermosetting
compound (LSF) SW4 outer sheath to BS7655 section 2.6. 150/250 volts grade manufactured to
BS7917/BS6883 and UKOOA design flame retardant to IEC60332-1 and IEC60332-3-22. Halogen
free to IEC60754-1,2 and low smoke to IEC61034-1,2. Fire resistant to IEC60331-21 IEC60331
(BS7917).
CCC
Code
GMR01
GPS01
GMS01
GPT01
GMT01
GPU01
GMU01
GPF02
GMF02
GPG02
GPX02
GMX02
GPH02
GMH02
GPJ02
GMJ02
GPK02
GMK02
GPL02
GML02
GNL02
GPM02
GMM02
GPR02
GMR02
GPS02
GMS02
GPT02
GMT02
GPU02
GMU02
GPF03
GMF03
Conductor
Size
(mm2)
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
2.50
2.50
Stranding
(mm)
No. Of
Pairs
Weight
(Kg/Km)
Sheath
Colour
UKOOA
Code
7/0.4
7/.04
7/.04
7/.04
7/.04
7/.04
7/.04
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.53
7/0.67
7/0.67
1Triple
3Triple
3Triple
7Triple
7Triple
12Triple
12Triple
1
1
2
1Quad
1Quad
3
3
7
7
12
12
20
20
20
27
27
1Triple
1Triple
3Triple
3Triple
7Triple
7Triple
12Triple
12Triple
1
1
310
630
630
1100
1100
1840
1840
300
300
410
410
410
600
600
1030
1030
1750
1750
2640
2640
2640
2970
2970
330
330
730
730
1220
1220
2150
2150
340
340
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GMR01
GPS01
GMS01
GPT01
GMT01
GPU01
GMU01
GPF02
GMF02
GPG02
GPX02
GMX02
GPH02
GMH02
GPJ02
GMJ02
GPK02
GMK02
GPL02
GML02
GNL02
GPM02
GMM02
GPR02
GMR02
GPS02
GMS02
GPT02
GMT02
GPU02
GMU02
GPF03
GMF03
Temperature limits:
-15 to +90°C. *Bending radius:
6 x overall diameter.
Core identification:
pairs - black , white numbered
triples - black, white, red numbered.
quad - black, white, red, blue numbered.
Should not be installed at
temperatures below -15°C.
Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.
124
*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending
radius (MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the
capabilities of their cable, it is not a specification defined in standards.
SECTION 12 Installation Accessories
125
FRaMinG and suPPoRt sYsteMs
AvAILABLE IN HOT DIP GALvANISED OR STAINLESS STEEL
126
AvAILABLE IN HOT DIP GALvANISED OR STAINLESS STEEL
*These items require a separate M10X40 cone bolt
127
lMl
LML Products Limited
Since its inception in 1968, LML has designed, manufactured and
supplied a comprehensive range of copper tube terminals including
bespoke specials. With in-house tooling and electroplating facilities,
LML will always provide a solution for its quality focused customers
in compliance with BS EN ISO 9001:2000
Copper Tube Terminals
LML terminals are manufactured from seamless copper tube to BS
EN 12449 and feature bell mouth entry up to 400mm2 and
chamfered entry from 500mm2 to 1000mm2. All terminals and
splices (other than parallel splices) are provided with an inspection
hole to ensure the conductor is fully inserted before crimping.
Internal barrel diameters suit standard cables as defined in BS EN
6360.
Standard finish is bright electro tin plating to BS EN 1872. Other
finishes can be provided, e.g. nickel or silver. Terminals are
independently tested to comply with BS EN 61238-1, and are also
approved for military use and by London Underground.
Crimp Tooling
LML Products also supply a large range of manual hydraulic tools
for crimping terminals from 1.5mm2 to 1000mm2. LML also supplies a
range of hydraulic crimping tools with rechargeable battery.
Med/High Voltage Crimp Terminals
LML Products manufactures a range of copper tube terminals to suit
11kv and 33kv. We also manufacture water blocked splices and
terminals.
Tel: 01642 217341 Fax: 01642 253723
email: sales@bilcourt.co.uk
www.bilcourt.co.uk
• Cables & leads
• Cable management
• Heating & ventilation
• Distribution, switchgear & enclosures
• Lamps
• Lighting products
• Security & emergency
• Site equipment, tools & fixings
• Wiring accessories
Middlesbrough Branch
Newcastle Branch
Riverside Park Road,
Middlesbrough,
Cleveland TS2 1QW
Tel: Sales 01642 241133 / Admin 254234
Fax: Sales 01642 226171 / Admin 226474
Email: sales@clevelandcable.com
Website: www.clevelandcable.com
Fisher Street Industrial Estate,
Walker,
Newcastle Upon Tyne NE6 4LT
Tel: 0191 263 3363
Fax: 0191 263 0601
Email: newcastle@clevelandcable.com
Bristol Branch
2 Bishops Court,
Calver Road,
Winwick Quay,
Warrington WA2 8QY
Tel: 01925 655383
Fax: 01925 655989
Email: warrington@clevelandcable.com
St. Georges Industrial Estate,
St. Andrews Road,
Avonmouth,
Bristol BS11 9HS
Tel: 01179 382222
Fax: 01179 382220
Email: bristol@clevelandcable.com
Glasgow Branch
56 Clydesmill Road,
Cambuslang Investment Park,
Cambuslang,
Glasgow G32 8RE
Tel: 0141 646 5000
Fax: 0141 646 5001
Email: glasgow@clevelandcable.com
Milton Keynes Branch
7 Fitzhamon Court,
Wolverton Mill South,
Milton Keynes MK12 6LB
Tel: 01908 221414
Fax: 01908 221661
Email: miltonkeynes@clevelandcable.com
Warrington Branch
Bilcourt Electrical Distributors Ltd Riverside Park Road,
Middlesbrough,
Cleveland TS2 1QW
Tel: 01642 217341
Fax: 01642 253723
Email: sales@bilcourt.co.uk
Aberdeen Office
Westhill Business Centre,
Arnhall Business Park,
Westhill, Aberdeen AB32 6UF
Tel: Sales 01224 330565 Fax: Sales 01224 330564
Email: aberdeen@clevelandcable.com
London Branch
Designed by ure orthDesign.com
Crabtree Manorway South,
Belvedere,
Kent DA17 6AB
Tel: 0208 311 4141
Fax: 0208 320 5454 Email: london@clevelandcable.com
Download