GENERATOR TRANSFER SWITCH
PRODUCT SPECIFICATION SHEET
MODEL NO:
TYPE:
PROJECT:
COMMENTS:
Full Light Output
LAMPS OPERATED
Allows operation of any switched
fixture from the generator or
inverter supply.
DESCRIPTION
PRODUCT ADVANTAGES
Allows auxiliary generator power on a
switched fixture
Full light output
SPECIFICATIONS
FEATURES
Input Current....................................................................................................250 mA
Will cold start and operate all specified lamps
Maximum Switching Voltage..............................................................3 Amps @ 120V
3 Amps @ 277V
Galvanized steel case
Emergency Operation................................................. The ETS will operate any lamp
type in the designated fixture for
the duration of the generator supply
Initial Illumination..................................................... The ETS allows operation of the
designated load at full light output
Operating Temp ......................................................................................... 0° to 50° C
Dual Voltage 120/277V 60hz
Available in flex or non-flex configuration
Meets or exceeds all National Electrical Code
and Life Safety Code Emergency Lighting
Requirements
5-Year Warranty. See Warranty Page for
details.
Weight...............................................................................................................1.0 lbs.
DIMENSIONS
SPECIALTY
8.0″ x 1.18″ x 1.125″ (mounting center 7.5″)
IOTA REV 060414
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734
COLD WEATHER
Approval........................................................................................................UL Listed
SELF-DIAGNOSTICS
Circuit Protection.......................................................................... 3A on Control Input
3A on Neutral and 120/277V Outputs
COMPACT
Input Voltage............................................................................ (Dual) 120/277V, 60Hz
SLIM PROFILE
Promotes energy savings by eliminating the
need for always-on fixtures
LINEAR
The IOTA ETS Emergency Transfer Switch allows the use of auxiliary generator or
inverter power on a switched fixture in power failure situations. The ETS senses the
loss of normal AC power and switches the AC ballast to the auxiliary supply. The ETS
allows operation of the load at full light output for as long as the generator or inverter
is able, and will work in conjunction with most any fixture on the designated circuit.
Allowing for the use of switched fixtures with a generator supply eliminates the need
for night lights and promotes increased energy savings. Dimming ballasts require one
ETS for each hot lead.
FLUORESCENT
OUTPUT
TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
ETS
GENERATOR TRANSFER SWITCH
OPTIONS
CONFIGURATION
ETS (NO FLEX)
ETS-R (W/ 24″ FLEX)
WIRING DIAGRAMS
TYPICAL BALLAST/GENERATOR APPLICATION
TYPICAL DIMMING BALLAST/GENERATOR APPLICATION
IOTA REV 060414
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734
TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com