ETS GENERATOR TRANSFER SWITCH PRODUCT SPECIFICATION SHEET MODEL NO: TYPE: PROJECT: COMMENTS: Full Light Output LAMPS OPERATED Allows operation of any switched fixture from the generator or inverter supply. DESCRIPTION PRODUCT ADVANTAGES Allows auxiliary generator power on a switched fixture Full light output SPECIFICATIONS FEATURES Input Current....................................................................................................250 mA Will cold start and operate all specified lamps Maximum Switching Voltage..............................................................3 Amps @ 120V 3 Amps @ 277V Galvanized steel case Emergency Operation................................................. The ETS will operate any lamp type in the designated fixture for the duration of the generator supply Initial Illumination..................................................... The ETS allows operation of the designated load at full light output Operating Temp ......................................................................................... 0° to 50° C Dual Voltage 120/277V 60hz Available in flex or non-flex configuration Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements 5-Year Warranty. See Warranty Page for details. Weight...............................................................................................................1.0 lbs. DIMENSIONS SPECIALTY 8.0″ x 1.18″ x 1.125″ (mounting center 7.5″) IOTA REV 060414 IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 COLD WEATHER Approval........................................................................................................UL Listed SELF-DIAGNOSTICS Circuit Protection.......................................................................... 3A on Control Input 3A on Neutral and 120/277V Outputs COMPACT Input Voltage............................................................................ (Dual) 120/277V, 60Hz SLIM PROFILE Promotes energy savings by eliminating the need for always-on fixtures LINEAR The IOTA ETS Emergency Transfer Switch allows the use of auxiliary generator or inverter power on a switched fixture in power failure situations. The ETS senses the loss of normal AC power and switches the AC ballast to the auxiliary supply. The ETS allows operation of the load at full light output for as long as the generator or inverter is able, and will work in conjunction with most any fixture on the designated circuit. Allowing for the use of switched fixtures with a generator supply eliminates the need for night lights and promotes increased energy savings. Dimming ballasts require one ETS for each hot lead. FLUORESCENT OUTPUT TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com ETS GENERATOR TRANSFER SWITCH OPTIONS CONFIGURATION ETS (NO FLEX) ETS-R (W/ 24″ FLEX) WIRING DIAGRAMS TYPICAL BALLAST/GENERATOR APPLICATION TYPICAL DIMMING BALLAST/GENERATOR APPLICATION IOTA REV 060414 IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com