AC Power Systems for Business-Critical Continuity™ AC Power Systems for Business-Critical Continuity™ Model Standard model Conversion type Long back-up time model Load 100%(4800w) 75%(3600w) 50%(2400w) 25%(1200w) 2 min 5 min 9 min 25 min +2 Batt Module 6 min 13 min 25 min 50 min +3 Batt Module 12 min 25 min 50 min 120 min 20 min 40 min 65 min 150 min 30 min 55 min 90 min 210 min Double conversion Battery Module Rectifier type IGBT +1 Batt Module Rated voltage 220/380Vac single-phase 3-wire or three-phase 4-wire (auto recognizing) Input parameters Input voltage range 120-276 Input frequency range Input power factor 45-55 Single phase >= 0.99 / 3-phase >=0.95 Battery Charging capability <3h for recharging to 90% of standard model Adapt 4.8kW/6kVA +4 Batt Module UPS +5 Batt Module Lead-acid maintenance free battery 12V/7.2AH +6 Batt Module 40 min 65 min 120 min 280 min Battery backup time of standard model >4minutes +7 Batt Module 50 min 70 min 150 min 310 min Model of battery module U16-07C1 +8 Batt Module 60 min 75 min 190 min 400 min Battery type Battery module specifications 430W X 660D X 88H (2U rack height), 50kg Output parameters Rated power 4.8 kW / 6 kVA Voltage precision 230Vac±3% Frequency precision 50+/-0.2% Output voltage THD <3% for linear load, <5% for non-linear load Load crest factor Expanded battery module 3:1 (comply with IEC 62040-3) Step load performance List of optional parts 100 System parameters and standard Rack rail Whether parallel operation can be realized Parallel output module Support maximum 3+1 parallel operation Whether rack mounting mode is supported System efficiency Yes Switching time (power failure) 0 Noise <51 DB Language Yes (optional) Safety GB4943-1995 Surge protection Dimensions Weight Warranty Modbus card Conducted emission: EN50091-2 EN55022 ClassA Immunity: EN61000-4-2.3.4.6.8.11 Level III EN61000-4-5 Level IV Meet installation requirements of IEC60664-1 IV Be able to withstand at least 6KV/3KA 1/2/50uS+8/20uS Protection level IP21 430W X 660D X 88H (2U), with battery 430W×660D×88H 2U 23KG 25KG 1 year Communication and management Interface type USB/intelligent slot (dry contact/SNMP card/Modbus card) Environmental parameters Operating temperature 0 - 40˚C Relative humidity 5 - 95% Altitude 1500m SNMP card Dry contact card Chinese/English Whether LCD display is available EMC LCD >91% (with intelligent fan speed regulation function) Extendable battery charging module 2U, with 16 internal cells Used in rack mounting mode 2U, used for 1+ 1 parallel output Can be changed to LED panel on site Used for remote TCP/IP-based Web monitoring, support remote safety shutdown Used for signal expansion in dry contact communication mode Used for BMS connection or other industrial application 2U, 192V / 10A for extended battery capacity