www.sylvania.com QUICKTRONIC® MH Electronic Metal Halide Systems Normal Ballast Factor Professional Series Lamp / Ballast Guide QTP 2x20MH/UNV QTP 1x20MH/SQ UNV QT 1x20MH/SLIM 120V M156*; C156 QTP 1x39MH/UNV QTP 2x39MH/UNV QTP 1x39MH/SQ UNV QT 1x39MH/SLIM 120V M130*; C130 QTP 1x70MH/UNV QTP 1x70MH/SQ UNV QT 1x70MH/SLIM 120V M139*/M98: C139/C98 *earlier reference obsolete Key System Features • • • • • • • • • Constant power regulation Universal input voltage High power factor Low harmonic distortion Small size and lightweight 80ºC case temperature UL, FCC End-of-life shut down Internal IDTP (Insulation Detection Thermal Protector) • QUICK 60+® warranty • RoHS compliant • Lead-free solder, printed circuit board and manufacturing process Application Information SYLVANIA QUICKTRONIC MH is ideally suited for: • Track lighting • Downlighting • Landscape lighting • Retail • Hospitality • Institutional • Commercial ECS054R7 – 10/2010 Small and efficient, QUICKTRONIC MH ballasts operate silently and provide energy savings up to 15% compared to magnetic ballasts. New smaller sizes allow for more flexible fixture designs and applications while maintaining the features and system advantages of the standard size ballast. The Mini Slim and Mini Square are 50% smaller than the standard sized can. Installation is simplified by our singlepiece ballasts that incorporate the ballast, capacitor, ignitor and mounting brackets of conventional systems. Two lightweight mounting styles allow for easy assembly in any fixture application. QUICKTRONIC MH eHID ballasts are RoHS compliant and feature lead-free solder, printed circuit boards and manufacturing process. Setting the standard for quality, QUICKTRONIC MH ballasts are also covered by our QUICK 60+® warranty, the first and most comprehensive system warranty in the industry. System Information SYLVANIA QUICKTRONIC MH ballasts and SYLVANIA METALARC® POWERBALL® CERAMIC lamps are perfectly matched to provide optimal system performance. Our electronically controlled system delivers several advantages over conventional components, including improved lumen maintenance and extended photometric life. The superior power regulation design produces consistently brilliant light output and color throughout the life of the lamp. This circuitry also provides constant light output during periods of fluctuating supply voltage. All QUICKTRONIC MH eHID ballasts are equipped with an end-of-life shut down function. This prevents continuous starting after lamps extinguish which may cause permanent damage to the ballast. All low wattage (</= 150W) QUICKTRONIC universal input voltage (120-277V) eHID ballasts are equipped with an internal IDTP (Insulation Detection Thermal Protector). This is a precision temperature gauge that will shut the ballast down at the maximum case temperature to prevent internal Enclosure Styles F = Feet Mount for track light fixtures (All leads exit side of ballast, as shown on next page.) J = J-Box Mount with PEM studs for recessed downlight fixtures (All leads exit middle/bottom of ballast, as shown on next page.) damage of electronic components. The internal thermal protection feature affords an original equipment manufacturer (OEM) the ability to remove all external thermal protection devices. In order to maximize the benefits of this unique feature the ballast must be properly installed. (See “installation notes” for detail). QT MH QTP 1x100MH/UNV M90/M140*; C90 SYLVANIA QUICKTRONIC MH electronic HID (eHID) ballasts feature a state of the art electronic design to deliver performance levels unattainable with standard magnetic lighting systems. SPECIFICATION DATA Catalog # Date Type Project Prepared by ® MH QUICKTRONIC SYSTEMS Comments Professional Series Electronic Metal Halide Systems, Universal Voltage (120-277V) Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Input Current (AMPS) Lamp Type 1 Performance Guide Rated Ballast Input System Lumens No. of Internal Factor System Wattage Efficacy (lm) Lamps IDTP2 (BF) Lumens (W) (lm/W) 51968 51969 QTP2X20MH UNV F3 QTP2X20MH UNV J3 120-277 0.38/0.16 20W T4.5 1700 2 Yes 1.0 3400 46 74 51910 51911 QTP1x39MH/UNV-F QTP1x39MH/UNV-J 120-277 0.39/0.17 39W T6 3400 1 Yes 1.0 3400 44 77 51970 51971 QTP2X39MH UNV F3 QTP2X39MH UNV J3 120-277 0.75/0.33 39W T6 3400 2 Yes 1.0 6800 89 76 51912 51913 QTP1x70MH/UNV-F QTP1x70MH/UNV-J 120-277 0.67/0.29 70W T6 7000 1 Yes 1.0 7000 79 89 51914 51915 QTP1x100MH/UNV-F QTP1x100MH/UNV-J 120-277 0.96/0.41 100W E17 9700 1 Yes 1.0 9700 110 88 1: Data based on ceramic lamp types except where noted. 2: Internal IDTP - Insulation Detection Thermal Protector (see system information for detail). 3: Ballast can operate 1 or 2 lamps, cap off unused leads individually for 1 lamp operation. QT MH Installation Notes 1. Proper ballast mounting must be followed to allow for maximum thermal dissipation: a. F can ballast should be mounted with the “feet” side placed tightly against the inside of the fixture b. J can ballast should be mounted with the PEM Stud side placed tightly against the inside of the fixture 2. Lamp holders and conductors: a. Use minimum 4kV pulse rated lamp holder. b. Use minimum 4kV pulse rated or UL style 3561 wire for lamp connections. The red lead must be connected to center terminal of lamp. Do not connect any lamp lead to neutral or ground. 3. Grounding: a. The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting, and acceptable EMI/RFI performance. Install ballast in accordance with national and local electrical codes. 4. Auto shut down function including end-of-life and thermal protection: a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown. 5. Control: Do not operate with dimmer or occupancy sensor. More installation considerations are in the QUICKANSWER section of the Ballast Technology and Specification Guide. Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast with universal input voltage. Specifications Voltage Range: ±10% of 120-277V rated line (108-305V) Input Frequency: 50/60 Hz Power Factor: >98% Low THD: <10% Starting Temp: -22°F/-30°C min. Lamp Frequency: 165Hz Square Wave UL listed and UL listed to Canadian safety standard, Type 1, Outdoor Suitable for recessed use 80°C Max. Case Temperature, Thermally Protected FCC 47CFR Part 18 Non-Consumer Sound Rated A ANSI C62.41 Cat. A Transient Protection Remote Mounting capability 3 Lamp current crest factor: <1.2 RoHS Compliant 4 3 Remote Mounting (max. wire length from ballast case to lampholder): Typically 6ft. but varies by application. For remote mounting distances up to 15 ft, use #18 AWG minimum 7.5kV pulse rated wire. Output wires should be enclosed in 1/2" metal conduit to minimize EMI (electromagnetic interference). Wire and ground ballast, fixture, conduit & lighting system per NEC (National Electric Code). 4 Complies with European Union Restriction of Hazardous Substances Directive. System Life / Warranty QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. Packaging: Quantity: 10 pieces per carton Weight: 6 lbs. per carton (0.6 lbs each) Black White Black BALLAST White INPUT Green Blue Red Item Number 51910 QTP 1 x 39 MH / UNV F INPUT Green BALLAST Blue Blue/White Red Red/White Case Type (Mounting Style) QUICKTRONIC PROFESSIONAL Line Voltage (120-277V) Number of Lamps (1) Metal Halide Primary Lamp Wattage Max. Case Temp. Measured at Warranty Period Tc Point <75°C 5 years <80°C 3 years OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. SPECIFICATION DATA Catalog # Date Type Project Prepared by MH QUICKTRONIC ® Comments Professional Series Electronic Metal Halide Systems, Mini Sized Item Number OSRAM SYLVANIA Description 51958 QT1x20MH 120V SLIM 51959 QTP1x20MH UNV SQ F 51956 QTP1x20MH UNV SQ J 51960 QT1x39MH 120V SLIM 51961 QTP1x39MH UNV SQ F Performance Guide Input Voltage (VAC) Input Current (AMPS) Lamp Type 1 Rated Ballast Input System Lumens No. of Internal Factor System Wattage Efficacy (lm) Lamps IDTP2 (BF) Lumens (W) (lm/W) 120 0.20 20W T4.5 1700 1 No 1.0 1700 23 74 120-277 0.19/0.09 20W T4.5 1700 1 Yes 1.0 1700 23 74 120-277 0.19/0.09 20W T4.5 1700 1 Yes 1.0 1700 23 74 Formerly: QT1x20MH UNV SQ 39W T6 3400 1 No 1.0 3400 44 77 120-277 0.38/0.17 120 0.38 39W T6 3400 1 Yes 1.0 3400 44 77 120-277 0.38/0.17 39W T6 3400 1 Yes 1.0 3400 44 77 70W T6 7000 1 No 1.0 7000 79 89 120-277 0.66/0.29 70W T6 7000 1 Yes 1.0 7000 79 89 120-277 0.65/0.27 70W T6 7000 1 Yes 1.0 7000 79 89 Formerly: QT1x39MH UNV SQ 51957 QTP1x39MH UNV SQ J 51962 QT1x70MH 120V SLIM 51963 QTP1x70MH UNV SQ F 120 0.64 Formerly: QT1x70MH 120V SQ 51964 QTP1X70MH UNV SQ J Installation Notes 1. Proper ballast mounting must be followed to allow for maximum thermal dissipation: a. F can ballast should be mounted with the “feet” side placed tightly against the inside of the fixture b. J can ballast should be mounted with the PEM Stud side placed tightly against the inside of the fixture 2. Lamp holders and conductors: a. Use minimum 4kV pulse rated lamp holder. b. Use minimum 4kV pulse rated or UL style 3561 wire for lamp connections. The red lead must be connected to center terminal of lamp. Do not connect any lamp lead to neutral or ground. 3. Grounding: a. The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting, and acceptable EMI/RFI performance. Install ballast in accordance with national and local electrical codes. 4. Auto shut down function including end-of-life and thermal protection: a. Disconnect power when servicing. Cycle power to reset ballast after auto shutdown. 5. Control: Do not operate with dimmer or occupancy sensor. More installation considerations are in the QUICKANSWER section of the Ballast Technology and Specification Guide. Specifications Input Voltage Range: ±10% of rated input Input Frequency: 50/60 Hz Power Factor: >98% Low THD: QTP: <10% QT: <20% Starting Temp: -22°F/-30°C min. Lamp Frequency: 165-170Hz Square Wave UL Listed, Type 1, Outdoor Suitable for recessed use 20&39W: 85°C Max. Case Temp. 70W: 90°C Max. Case Temp. Thermally Protected FCC 47CFR Part 18 Non-Consumer Sound Rated A ANSI C62.41 Cat. A Transient Protection Remote Mounting capability3 Lamp current crest factor: <1.2 All Slim ballasts have a plastic can. All others are metal. RoHS Compliant 4 3 Remote Mounting (max. wire length from ballast case to lampholder): Typically 6ft. but varies by application. For remote mounting distances up to 15 ft, use #18 AWG minimum 7.5kV pulse rated wire. Output wires should be enclosed in 1/2" metal conduit to minimize EMI (electromagnetic interference). Wire and ground ballast, fixture, conduit & lighting system per NEC (National Electric Code). 4 Complies with European Union Restriction of Hazardous Substances Directive. System Life / Warranty QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. Packaging: Quantity: 40 pieces per carton Weight: 36 lbs. per carton (0.9 lbs each) White Black BALLAST Max. Case Temp. Measured at Tc Point 70W: <90°C <80°C 20 & 39W: <85°C <75°C INPUT Green Blue Red Item Number 51961 QTP 1 x 39 MH / UNV SQ F Case Type (Mounting Style) QUICKTRONIC PROFESSIONAL Case Type Number of Lamps (1) Line Voltage (120-277V) Primary Lamp Wattage Metal Halide Warranty Period 3 years 5 years 3 years 5 years OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. QT MH 1: Data based on ceramic lamp types except where noted. 2: Internal IDTP - Insulation Detection Thermal Protector (see system information for detail). Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast. SPECIFICATION DATA Catalog # Date Type Project Prepared by MH QUICKTRONIC ® Comments Professional Series Electronic Metal Halide Systems Universal Voltage (120-277V) Performance Guide J Case Ballast shall be a metal halide SYLVANIA QUICKTRONIC MH electronic ballast with universal input voltage. F Case 7.0" (177.8mm) 7.0" (177.8mm) 4.6" (117.2mm) 5.0" (128mm) 2.85" (72.4mm) QT MH 3.4" (87.3mm) 2.0" (50.8mm) 1.4" (35.6mm) Tc measurement point 4.6" (117.2mm) 3.4" (87.3mm) 1.4" (35.6mm) PEM studs on 2" centers (#8-32 x 0.375" long) SQ F Case 75.3mm 3.0" 30.3mm 1.2" Tc measurement point SQ J Case 254.1mm 10.0" 90.0mm 3.5" 65.0mm 2.6" Mount 86.0mm 3.4" Mount 4.0mm 0.2" (2)PL WIRE LENGTH 178mm (7.0") 254mm 10.0" ©2010 OSRAM SYLVANIA PEM STUD #8-32 x .375" LONG Slim Case 127.8mm 5.0" 75.3mm (3.0") 254mm 10.0" 120.0mm 4.7" 44.2mm 1.7" 132.0mm 5.2" MOUNT LOC 140.0mm 5.5" 30.0mm 1.2" 37.6mm (1") 50.8mm (2.0") 39.25mm (1.5") 90mm (3.5") The maximum case temperature test point is located on the bottom of the case and is designated by “Tc” symbol. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. SYLVANIA, QUICK60+, METALARC and the system solution are registered trademarks of OSRAM SYLVANIA Inc. QUICKTRONIC and POWERBALL are registered trademarks of OSRAM GmbH.