Ecofit conversion kits are an economical means of increasing

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
Ecofit conversion kits are an economical means of increasing
fixture efficiency and energy savings. Ecofit conversion kits are
ideal for applications where fixture removal is cost-prohibitive.
Catalog #
Ecofit conversion kits are designed for applications with conventional
1 or 2-lamp strip/channel fixtures, such as task, coves, display
cases, utility, and general area lighting. Convert existing T12 or T8
Slimline lamp technology with the latest T8 and T5 systems and
save up to 50% in energy.
Comments
Type
Project
Date
Prepared by
SPECIFICATION FEATURES
Construction
Optical Modules
Installation
Socket tracks are die formed
20 gauge cold rolled steel w/
adjustable attachment straps for
a wide range of industrial channel
sizes. Toolless ballast access for
easy wiring access and installation.
Die formed reflectors faceted
for 1 and 2 lamp configurations
with two optical distributions
–medium and wide. Medium
beam optical modules utilize
95% specular aluminum while
the wide distribution utilizes
a high performance 91%
reflective polyester powder
coated finish. Optional ballast
channel cover that fits over
housings 4" to 5-1/4" wide
Retrofit installation in
standard 4' and 8' strip
lengths and fits channels
4" to 5-1/4" wide.
Hardware included. All
kits require assembly in
the field.
Electrical
Optional electronic ballasts are
Class “P” and are positively
secured by mounting bolts in field.
When ordering kits only you need
to specify ballast type and system
to designate shunted or unshunted
sockets. Twist-lock lampholders.
UL Classified for retrofit
applications. Suitable for damp locations.
Packaging
Kits are bulk packed for
easier handling based on
project size and quantity
ordered. Consult factory
for other packaging
requirements, such as a
dedicated unit pack for
distribution.
INDUSTRIAL
RETROFIT KIT
4' OR 8'
1 OR 2 LAMPS
Energy Efficient
Conversion Kit
2-1/4"
[58mm]
10-5/8"
[270mm]
O P T I C A L R E F L E C TO R
STRIP KIT (WITH REFLECTOR)
5-1/8"
[131mm]
2-1/4" [58mm]
X
X=2-1/2"
[64mm]
10-5/8"
[270mm]
INSTALLATION
2 LAMP
All components
reflectors, socket
brackets, sockets,
screws, and wire nuts)
are included in each
kit for installation and
require only a few basic
tools for assembly.
STRIP KIT (NO REFLECTOR)
Y
1-5/8" [42mm]
Y=4" [102mm]
to
5-1/4"[134mm]
5-1/2"
[140mm]
Nominal
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
cooper lighting
ADF071340
EC S
p h otometrics
ECS-132-M-EB81
(1) 32W T8
2900 lumens
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.5 x
mounting height
Efficiency 91.7%
Test Report:
ECS132MEB81
AngleAlong II45° Across ⊥
0
721721 721
5
725727 724
10
714711 717
15
695699 701
20
676680 689
25
650658 673
30
624634 655
35
579605 645
40
537580 628
45
497548 613
50
438518 586
55
393486 576
60
332454 533
65
274417 498
70
219370 437
75
162310 376
80
112248 291
85
64137 133
90
2622 11
Effective floor cavity reflectance
20%
80%
70%
50%
70503010 70503010
503010
30%
503010
10%
50 3010
0%
0
109109 109109 97 92 87 83 87 79 71 65 79 68 60 53 72 60 51 44 66 53 44 37 60 47 38 32 56 43 34 28 52 39 31 25 49 36 28 22 45 33 25 20 97 82 70 61
54 48 43 39 36 33 30 93 79 67 58
51 46 41 38 34 32 29 91
72
57
47
39
33
29
25
22
20
18
106 106106 106 95 90 86 82 85 77 70 64 76 66 59 52 70 58 50 44 64 52 43 37 59 46 38 32 54 42 34 28 50 38 30 25 47 35 27 22 44 32 25 20 Candela
AngleAlong II45° Across ⊥
0
14811481 1481
5
15331504 1541
10
14661486 1496
15
14401480 1490
20
14011436 1459
25
13451383 1407
30
12671329 1363
35
12021263 1298
40
11211189 1256
45
10121120 1197
50
9061028 1118
55
797947 1062
60
704867 976
65
574772 894
70
462666 770
75
346552 602
80
235379 387
85
134180 174
90
4527 18
Coefficients of Utilization
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
ECS-232-M-EB81
Electronic Ballast
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 89.4%
Test Report:
ECS232MEB81
Candela
102 102 102 86 82 79 73 68 63 64 57 51
56 49 43 50 42 36 45 37 32 40 33 28 37 30 25 34 27 22 31 24 20 97 79 65 55
47 41 36 32 29 26 24 97 76 61 50
42 36 31 27 24 22 20 93 93 76 74 63 60 53 49 46 41 40 36 35 31 32 27 29 24 26 22 24 20 Zonal Lumen Summary
Luminance Data
Zone Lumens%Lamp %Fixture
57119.7 21.5
0-30
95232.8 35.8
0-40
180962.4
68
0-60
264591.2
99.4
0-90
266191.7 100.0
0-180
AverageAverage
Angle0-Deg
45-Deg
in Deg
cd/sm
cd/sm
452310 2549
552253 2787
652128 3247
752051 3937
852415 5164
Average
90-Deg
cd/sm
2848
3303
3871
4771
5003
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
20%
80%
70%
50%
70503010 70503010
503010
30%
503010
10%
50 3010
0%
0
106106 106106 96 91 86 82 86 78 71 65 78 68 60 53 71 59 51 44 65 53 44 38 60 47 39 33 55 43 35 29 52 39 31 25 48 36 28 23 45 33 25 21 95 81 70 61 54 48 43 39 36 33 30 91 78 67 58 52 46 42 38 35 32 30 89
71
58
48
40
34
30
26
23
21
19
104 104104 104 93 89 85 81 84 76 70 65 76 66 59 53 69 58 50 44 63 52 44 38 58 46 38 33 54 42 34 29 50 38 31 25 47 35 28 23 44 32 25 21 99 85 73 63 56 50 45 41 37 34 31 99 81 67 57 49 43 38 33 30 27 25 99 78 63 52 43 37 32 28 25 23 20 95 78 65 55 48 42 37 33 30 27 25 95 76 61 51 43 37 32 28 25 22 20 91 75 63 54 46 41 36 32 29 26 24 Zonal Lumen Summary
Luminance Data
Zone Lumens%Lamp %Fixture
119420.6
23.0
0-30
198334.2
38.2
0-40
368263.5
71.0
0-60
516189.0
99.5
0-90
518589.4 100.0
0-180
AverageAverage
Angle0-Deg
45-Deg
in Deg
cd/sm
cd/sm
454702 5204
554569 5429
654460 6007
754403 7005
855051 6774
91 73 60 50 42 36 32 28 25 22 20 Average
90-Deg
cd/sm
5564
6088
6949
7647
6544
O rderin g I nformation
SAMPLE NUMBER: 8ECS-232-M-NB-UNV-EB8-U
Width
[Blank]=4'
8=8' Tandem
Series
ECS=Ecofit Strip
No. of Lamps (Not Included)
1=1 Lamp
2=2 Lamps
Lamp Type
32=32W T8 Lamp (48")
54=54W T5HO Lamp (48")
Optics
BC=Ballast/Channel
Cover (Covers from
4" to 5-1/4" Wide)
M=Medium (Specular
Aluminum)
W=Wide (White)
Voltage (1)
NB=No Ballast
UNV=Universal Voltage
Ballast Included
Ballast/Socket Type (1)
T5 Ballasts
EBT_=T5 or T5HO Electronic Program Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor =1.0
T8 Ballasts
EB8__=T8 Electronic Instant Start. Total
Harmonic Distortion < 10%.
EB8__/L=T8 Electronic Instant Start with <
0.80 Ballast Factor.
EB8__/PLUS=T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15
ER8__=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%. (2)
Order Quantity - Packaging
U=Unit Pack or Bulk Pack (packaging will
be determined based on project size and
quantity ordered).
Consult factory for other packaging
requirements that require a dedicated pack unit.
Number of Ballasts
1=1 Ballast
2=2 Ballasts
[Blank]=No Ballast (NB Options Only)
S h ippin g I nformation
NOTES: (1)When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets. Ex: ECS-232-M-EB81-10B.
Recommended when using retrofits together with motion sensor, daylight harvesting or similar controls.
(2)
Catalog No.
Wt.
ECS-232-X-NB
ECS-254-X-NB
ECS-132-X-NB
ECS-154-X-NB
1.4 lbs.
1.4 lbs.
1.4 lbs.
1.4 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
1/13
ADF071340
Download