COOPER LIGHTING - METALUX ® DESCRIPTION Ecofit conversion kits are an economical means of increasing fixture efficiency and energy savings. Ecofit conversion kits are ideal for applications where fixture removal is cost-prohibitive. Catalog # Ecofit conversion kits are designed for applications with conventional 1 or 2-lamp strip/channel fixtures, such as task, coves, display cases, utility, and general area lighting. Convert existing T12 or T8 Slimline lamp technology with the latest T8 and T5 systems and save up to 50% in energy. Comments Type Project Date Prepared by SPECIFICATION FEATURES Construction Optical Modules Installation Socket tracks are die formed 20 gauge cold rolled steel w/ adjustable attachment straps for a wide range of industrial channel sizes. Toolless ballast access for easy wiring access and installation. Die formed reflectors faceted for 1 and 2 lamp configurations with two optical distributions –medium and wide. Medium beam optical modules utilize 95% specular aluminum while the wide distribution utilizes a high performance 91% reflective polyester powder coated finish. Optional ballast channel cover that fits over housings 4" to 5-1/4" wide Retrofit installation in standard 4' and 8' strip lengths and fits channels 4" to 5-1/4" wide. Hardware included. All kits require assembly in the field. Electrical Optional electronic ballasts are Class “P” and are positively secured by mounting bolts in field. When ordering kits only you need to specify ballast type and system to designate shunted or unshunted sockets. Twist-lock lampholders. UL Classified for retrofit applications. Suitable for damp locations. Packaging Kits are bulk packed for easier handling based on project size and quantity ordered. Consult factory for other packaging requirements, such as a dedicated unit pack for distribution. INDUSTRIAL RETROFIT KIT 4' OR 8' 1 OR 2 LAMPS Energy Efficient Conversion Kit 2-1/4" [58mm] 10-5/8" [270mm] O P T I C A L R E F L E C TO R STRIP KIT (WITH REFLECTOR) 5-1/8" [131mm] 2-1/4" [58mm] X X=2-1/2" [64mm] 10-5/8" [270mm] INSTALLATION 2 LAMP All components reflectors, socket brackets, sockets, screws, and wire nuts) are included in each kit for installation and require only a few basic tools for assembly. STRIP KIT (NO REFLECTOR) Y 1-5/8" [42mm] Y=4" [102mm] to 5-1/4"[134mm] 5-1/2" [140mm] Nominal LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS cooper lighting ADF071340 EC S p h otometrics ECS-132-M-EB81 (1) 32W T8 2900 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 91.7% Test Report: ECS132MEB81 AngleAlong II45° Across ⊥ 0 721721 721 5 725727 724 10 714711 717 15 695699 701 20 676680 689 25 650658 673 30 624634 655 35 579605 645 40 537580 628 45 497548 613 50 438518 586 55 393486 576 60 332454 533 65 274417 498 70 219370 437 75 162310 376 80 112248 291 85 64137 133 90 2622 11 Effective floor cavity reflectance 20% 80% 70% 50% 70503010 70503010 503010 30% 503010 10% 50 3010 0% 0 109109 109109 97 92 87 83 87 79 71 65 79 68 60 53 72 60 51 44 66 53 44 37 60 47 38 32 56 43 34 28 52 39 31 25 49 36 28 22 45 33 25 20 97 82 70 61 54 48 43 39 36 33 30 93 79 67 58 51 46 41 38 34 32 29 91 72 57 47 39 33 29 25 22 20 18 106 106106 106 95 90 86 82 85 77 70 64 76 66 59 52 70 58 50 44 64 52 43 37 59 46 38 32 54 42 34 28 50 38 30 25 47 35 27 22 44 32 25 20 Candela AngleAlong II45° Across ⊥ 0 14811481 1481 5 15331504 1541 10 14661486 1496 15 14401480 1490 20 14011436 1459 25 13451383 1407 30 12671329 1363 35 12021263 1298 40 11211189 1256 45 10121120 1197 50 9061028 1118 55 797947 1062 60 704867 976 65 574772 894 70 462666 770 75 346552 602 80 235379 387 85 134180 174 90 4527 18 Coefficients of Utilization Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 ECS-232-M-EB81 Electronic Ballast Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency 89.4% Test Report: ECS232MEB81 Candela 102 102 102 86 82 79 73 68 63 64 57 51 56 49 43 50 42 36 45 37 32 40 33 28 37 30 25 34 27 22 31 24 20 97 79 65 55 47 41 36 32 29 26 24 97 76 61 50 42 36 31 27 24 22 20 93 93 76 74 63 60 53 49 46 41 40 36 35 31 32 27 29 24 26 22 24 20 Zonal Lumen Summary Luminance Data Zone Lumens%Lamp %Fixture 57119.7 21.5 0-30 95232.8 35.8 0-40 180962.4 68 0-60 264591.2 99.4 0-90 266191.7 100.0 0-180 AverageAverage Angle0-Deg 45-Deg in Deg cd/sm cd/sm 452310 2549 552253 2787 652128 3247 752051 3937 852415 5164 Average 90-Deg cd/sm 2848 3303 3871 4771 5003 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 20% 80% 70% 50% 70503010 70503010 503010 30% 503010 10% 50 3010 0% 0 106106 106106 96 91 86 82 86 78 71 65 78 68 60 53 71 59 51 44 65 53 44 38 60 47 39 33 55 43 35 29 52 39 31 25 48 36 28 23 45 33 25 21 95 81 70 61 54 48 43 39 36 33 30 91 78 67 58 52 46 42 38 35 32 30 89 71 58 48 40 34 30 26 23 21 19 104 104104 104 93 89 85 81 84 76 70 65 76 66 59 53 69 58 50 44 63 52 44 38 58 46 38 33 54 42 34 29 50 38 31 25 47 35 28 23 44 32 25 21 99 85 73 63 56 50 45 41 37 34 31 99 81 67 57 49 43 38 33 30 27 25 99 78 63 52 43 37 32 28 25 23 20 95 78 65 55 48 42 37 33 30 27 25 95 76 61 51 43 37 32 28 25 22 20 91 75 63 54 46 41 36 32 29 26 24 Zonal Lumen Summary Luminance Data Zone Lumens%Lamp %Fixture 119420.6 23.0 0-30 198334.2 38.2 0-40 368263.5 71.0 0-60 516189.0 99.5 0-90 518589.4 100.0 0-180 AverageAverage Angle0-Deg 45-Deg in Deg cd/sm cd/sm 454702 5204 554569 5429 654460 6007 754403 7005 855051 6774 91 73 60 50 42 36 32 28 25 22 20 Average 90-Deg cd/sm 5564 6088 6949 7647 6544 O rderin g I nformation SAMPLE NUMBER: 8ECS-232-M-NB-UNV-EB8-U Width [Blank]=4' 8=8' Tandem Series ECS=Ecofit Strip No. of Lamps (Not Included) 1=1 Lamp 2=2 Lamps Lamp Type 32=32W T8 Lamp (48") 54=54W T5HO Lamp (48") Optics BC=Ballast/Channel Cover (Covers from 4" to 5-1/4" Wide) M=Medium (Specular Aluminum) W=Wide (White) Voltage (1) NB=No Ballast UNV=Universal Voltage Ballast Included Ballast/Socket Type (1) T5 Ballasts EBT_=T5 or T5HO Electronic Program Start. Total Harmonic Distortion < 10%. Standard Ballast Factor =1.0 T8 Ballasts EB8__=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. EB8__/L=T8 Electronic Instant Start with < 0.80 Ballast Factor. EB8__/PLUS=T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15 ER8__=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. (2) Order Quantity - Packaging U=Unit Pack or Bulk Pack (packaging will be determined based on project size and quantity ordered). Consult factory for other packaging requirements that require a dedicated pack unit. Number of Ballasts 1=1 Ballast 2=2 Ballasts [Blank]=No Ballast (NB Options Only) S h ippin g I nformation NOTES: (1)When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets. Ex: ECS-232-M-EB81-10B. Recommended when using retrofits together with motion sensor, daylight harvesting or similar controls. (2) Catalog No. Wt. ECS-232-X-NB ECS-254-X-NB ECS-132-X-NB ECS-154-X-NB 1.4 lbs. 1.4 lbs. 1.4 lbs. 1.4 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 1/13 ADF071340