PRODUCT SPECIFICATION SPECIFICATION INFORMATION

advertisement
1
CABLE SUSPENDED
Lumium Cat. #:
Project:
Type:
(CS)
PRODUC T DESCRIPTION:
Minimalism stretched. The largest of the three in the
Oxygen series, O3 is the most versatile. It maintains the
clean lines and simplicity of its smaller counterparts while
boasting the ability to house multiple T5 and T8 lamps and
integral ballasts in a single fixture. O3 is engineered with
exceptional optics for high fixture efficacy.
3-5/16” DIA
FROSTED CLEAR OR
FROSTED WHITE LENS
(1 OR 2) T5, T5HO OR
T8 LAMP(S)
FEATURES:
1/16” aircraft cable suspension system
Integral ballasts for all options
High fixture efficacy
Multiple lamps per fixture
Extruded aluminum housing
High transmission frosted lenses
Numerous customizable details
No visible fasteners
3/8” thick machined end caps
HIGH REFLECTANCE
ENGINEERED REFLECTOR
INTEGRAL BALLAST
PRECISION MACHINED
ALUMINUM END CAP
EXTRUDED ALUMINUM
HOUSING
P R O D U C T S P E C I F I C AT I O N
FIXTURE
ORIENTATION
FIXTURE
TYPE
MOUNTING
O3
CS
O3
Oxygen3
CS Cable
Suspended
D Direct
I Indirect
R Rotational
NOMINAL
LENGTH
LAMP
1T5
2T5
1T5HO
2T5HO
1T8
2T8
2
3
4
6
8
CR__
2’
3’
4’
6’
8’
Continuous
Run - Specify
run length in
feet (ie: CR42)
BALLAST
OPTIONS
VOLTAGE
1
2
3
U
120v
277v
347v
Universal
(120-277v)
IS Instant Start
RS Rapid or
program Start
SB Specific Ballast*
DIM Dimming**
HOUSING
FINISH
HARDWARE
DETAIL FINISH
SC Satin Clear
(Anodize)
SW Satin White
(powder coat)
CF Custom Finish
(Consult factory)
MF Machined Finish
(standard)
CF Custom Finish
(Consult factory)
*Specify and contact factory
**See Ballast section below
for more information
[Shop drawings
will be provided]
CANOPY
FINISH
CANOPY SIZE
OPTIONS*
SW Satin White
CC Custom
Canopy finish*
55 5” Power feed canopy
5” non-power feed canopy
52 5” Power feed canopy
2” non-power feed canopy
50 5” Power feed canopy
No canopy on non power side
*Consult factory
*See options section and installation
instructions for more information.
POWER CORD
COLOR
W White
OPTIONS
Gray
Black
Clear Braided
Braided Sleeve
(Steel weave)
CC Custom Cord*
G
B
CB
BS
AIRCRAFT
CABLE LENGTH*
4 4’
CL_ Custom Length
Specify in feet
(ie: CU6 for 6’)
Consult factory
to confirm spec
LENS
CF Clear Frost
WF White Frost
CC Custom Color*
*Consult factory
*Cables are field
adjustable
*Consult factory
OPTIONS/
CUSTOMIZATION*
Blank No customization
EMB Emergency Battery backup
ballast*
CR Cusomization Requested*
Lumium offers an array of
options - See the options section
for more information. custom
concepts are also possible
*Consult factory for all custom
options or custom concept requests
2 - EMB: See ballast section below
S P E C I F I C AT I O N I N F O R M AT I O N
G ENERAL NOTES :
All fixtures are UL listed for dry and damp locations.
Please contact the factory with any specification questions.
Italicized grayed out options may have additional costs
and/or lead times.
FI XTURE OR IENTATION:
“Direct” (D) for downlight applications
“Inirect” (I) for uplight applications
“Rotational” (R) for adjustable applications: 360 degree
rotational capacity
VOLTAGE:
System voltage is helpful as it provides more ballast options.
Please use the Universal (U) specification only when the
project voltage is unknown. For integral ballast options,
fixture voltage must be specified.
BALLAST:
Oxygen3 can accommodate almost any ballast requirement
inside the fixture, including dimming and emergency battery
backup. If there is a specific ballast requirement or if there are
any questions, please contact the factory.
1) DIMMING: Contact factory for specific dimming information.
2) EMERGENCY: Specify ballast type under the Ballast Options
category. Specify EMB under the Options/Customization
category at the end of the cut sheet. Remote ballast housing is
required for this fixture with EM requirements. Contact factory.
F I NI S HES :
The standard finish is a satin white powder coated or satin clear
anodized housing with Machined Finish hardware. Machined
finish is preferable for the machined components (Hardware
Detail) - Powder coating may result in additional costs. Please
consult the factory with any questions about standard or custom
finishing options.
A IRC R A FT C A B L E L E N GT H :
Aircraft cable is field adjustable and cutable. For drops longer
than 4’, specify a cable length which encompasses that distance.
L E NSES:
Clear Frost (CF) Highly transmissive lens, but does have lamp
imaging with this fixture.
White Frost (WF) should be used when lamp imaging is a
concern. This option slightly reduces fixture efficacy.
C USTO M IZAT IO N:
We have numerous custom options available as seen above.
From simple options to complete custom requests, we are more
than willing to accommodate any creative notions you might
have. Just ask.
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
O3-0813
2
R O TAT I O N A L A R M M O U N T
Lumium Cat. #:
Project:
Type:
PRODUC T DESCRIPTION:
Minimalism stretched. The largest of the three in the
Oxygen series, O3 is the most versatile. It maintains the
clean lines and simplicity of its smaller counterparts while
boasting the ability to house multiple T5 and T8 lamps and
integral ballasts in a single fixture. 360 degree smooth
rotation with positive stop and impeccably clean lines
complete the O3 RAM fixture line.
3-5/16” DIA
FROSTED CLEAR OR
FROSTED WHITE LENS
(1 OR 2) T5, T5HO OR
T8 LAMP(S)
FEATURES:
5/8” diameter rigid tube arm mounting
360 rotation option - with mechanical locking
Integral ballasts for all options
High fixture efficacy
Multiple lamps per fixture
Extruded aluminum housing
Numerous customizable details
No visible fasteners
3/8” thick machined end caps
HIGH REFLECTANCE
ENGINEERED REFLECTOR
INTEGRAL BALLAST
PRECISION MACHINED
ALUMINUM END CAP
EXTRUDED ALUMINUM
HOUSING
P R O D U C T S P E C I F I C AT I O N
FIXTURE
TYPE
MOUNTING
O3
R AM
O3
Oxygen3
RAM Rotational
Arm
Mount
NOMINAL
LENGTH
LAMP
1T5
2T5
1T5HO
2T5HO
1T8
2T8
2
3
4
6
8
CR__
(RAM)
2’
3’
4’
6’
8’
Continuous Run Specify run length
in feet (ie: CR42)
1
2
3
U
HOUSING
FINISH
HARDWARE
DETAIL FINISH
SC Satin Clear
(Anodize)
SW Satin White
(powder coat)
CF Custom Finish
(Consult factory)
MF Machined Finish
(standard)
CF Custom Finish
(Consult factory)
BALLAST
OPTIONS
VOLTAGE
IS Instant Start
RS Rapid or
program Start
SB Specific Ballast*
DIM Dimming**
120v
277v
347v
Universal
*Specify and contact factory
**See Ballast section below for
more information
[Shop drawings
will be provided]
MOUNTING/
COVER PLATE
4CPF FLAT 4” diameter
Cover Plate - For use
with a 3-O mud ring
4CPC CURVED 4” diameter
Cover Plate - For use
with a 3-O mud ring
1TR 1” Trim Ring - for use
when mounting to
furniture
CCP Custom Cover Plate
(Consult factory)
ARM LENGTH
6
9
12
CAL
6”
9”
12”
Custom Arm
Length Consult factory
LENS
CF Clear Frost
WF White Frost
CC Custom Color
OPTIONS/
CUSTOMIZATION*
Blank No customization
EMB Emergency Battery backup
ballast*
CR Cusomization Requested*
Lumium offers an array of
options - See the options section
for more information. custom
concepts are also possible
*Consult factory for all custom
options or custom concept requests
2 - EMB: See ballast section below
S P E C I F I C AT I O N I N F O R M AT I O N
GE NERAL NOTES :
All fixtures are UL listed for dry and damp locations.
Please contact the factory with any specification questions.
Italicized grayed out options may have additional costs
and/or lead times.
VO LTAGE:
System voltage is helpful as it provides more ballast options.
Please use the Universal (U) specification only when the
project voltage is unknown. For integral ballast options,
fixture voltage must be specified.
A RM LE NGTH :
Arms can be specified to desired lengths. Please note, arm
lengths longer than 18” may require additional support
depending upon the fixture and options.
BALLAST:
Oxygen3 can accommodate almost any ballast requirement
inside the fixture, including dimming and emergency battery
backup. If there is a specific ballast requirement or if there are
any questions, please contact the factory.
1) DIMMING: Contact factory for specific dimming information.
2) EMERGENCY: Specify ballast type under the Ballast Options
category. Specify EMB under the Options/Customization
category at the end of the cut sheet. Remote ballast housing is
required for this fixture with EM requirements. Contact factory.
F I NI S HES :
The standard finish is a satin white powder coated or satin clear
anodized housing with Machined Finish hardware. Machined
finish is preferable for the machined components (Hardware
Detail) - Powder coating may result in additional costs. Please
consult the factory with any questions about standard or custom
finishing options.
M O UNT ING PL AT ES:
The standard arm mounting configuration uses 3-O mud rings, a
steel mounting plate, and machined cover. A small 1” O.D. ring
can be used with furniture applications. See installation
instructions or consult factory with any questions.
L E NSES:
Clear Frost (CF) Highly transmissive lens, but does have lamp
imaging with this fixture.
White Frost (WF) should be used when lamp imaging is a
concern. This option slightly reduces fixture efficacy.
C USTO M IZAT IO N :
We have numerous custom options available as seen above.
From simple options to complete custom requests, we are more
than willing to accommodate any creative notions you might
have. Just ask.
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
O3-0813
3
D E TA I L E D S P E C I F I C AT I O N I N F O R M AT I O N
FIXTU R E CONST RUC T ION:
Housings: Extruded aluminum
Lenses: Extruded frosted acrylic
End caps: Machined aluminum
Reflectors: Specular, semi-specular, or high reflectance white
Internal components: Formed aluminum or steel sheet metal
No visible fasteners (unless requested as a custom option)
FIN IS HES:
Standard housing finishes are Satin Clear (SC) (anodized) and
Satin White (SW) (powder coated). Custom anodized and
powder coated finishes are available. Let us know what you are
looking for and we will find a way to make it happen.
Given the precision nature of the product lines, whenever
possible machined finishes are preferred for the machined
components and are typically less expensive.
Cut sheets are set up so that two-tone finishes can be easily
ordered. This option lends to an even higher end feel and
creates a unique look. More detailed finishing is available if
desired or needed. Contact the factory with specific requests
or finish questions.
L EN S ES :
Clear Frost (CF): We have created our own acrylic blend to
create a highly transmissive lens that significantly diminishes
lamp imaging. This is our recommended lens for most fixtures.
White Frost (WF) is the ideal selection for reducing or
eliminating lamp imaging and diminishing socket shadows in
longer fixtures (6’ or greater) and continuous runs. However,
this option does reduce fixture efficacy.
Custom lens colors and styles are available as well. If there is
a specific request or project requirement, please contact the
factory.
L A M PS :
Lamping options: T5, T5HO, and T8 (fixture dependent)
4’ T5 and T8 lamps offer the best potential efficacy.
T5HO lamps offer the highest lumen output per lamp
allowing for fewer fixtures in a space.
T5 and T5HO lamps are recommended for most Lumium
fixtures as their smaller respective size allows for greater light
distribution control and overall fixture efficacy. Typically the
smallest fixtures in a series can only utilize T5 or T5HO lamps
as T8 lamps are too large for the small profiles.
F I X TU R E L E N GT H S :
Fixtures are measured in nominal lengths. For specific fixture
measurements and mounting information please see the
installation instructions. (5’ T5 and T5HO lamp fixtures are
available as a custom option. Consult factory.)
Lamp, nominal length, and corresponding fixture wattage
information is as follows.
T5
T5HO
T8
2' 14w
24w
17w
3' 21w
39w
25w
4' 28w
54w
32w
6' 2x21w
2x39w 2x25w
8' 2x28w
2x54w 2x32w
Continuous Run (CR) options are available for just about
every fixture type and option. There are exceptions. Please
contact the factory with specific run length information and
questions.
BAL LASTS :
Ballast specification is often dependent upon the fixture,
options, and installation.
Instant Start (IS) ballasts work best when fixtures will not be
switched on/off frequently (ie: motion sensor in a restroom).
They also offer thinner power cords with remote ballast cable
suspended applications.
Rapid Start (RS) ballasts should be used when fixtures will be
switched often. There are more specification grade RS ballast
options. When remote ballasts are used on cable suspended
fixtures, the power cord is typically thicker.
Dimming (DIM) ballasts work great with the larger fixture
lines (typically any fixture with a “3” in the name). Dimming
ballasts have significant lead restrictions, limiting the ballast
to furthest socket distance. Please consult the factory with
questions or specific dimming requirements and we will
ensure the proper specification.
Emergency (EM) ballasts can be specified with just about any
fixture configuration. For integral EM ballast options, the
fixture typically needs to be at least 3’ long; 4’ is the safest
option. Consult the factory with any questions.
KN U C KL E / E N D CA P/ COV E R P L AT E ST YL ES :
These details are offered to provide subtle specification
differences to suit project needs. Customization is available if
another aesthetic is desired. Please contact the factory with
any specific requests.
MO U N T IN G :
Cable Suspended (CS and CS-R): 1/16” aircraft cable
suspension system. Fixtures can be static down-lights: Direct
(D), static up-lights: Indirect (I), or Rotational (R). Rotational
fixtures offer just over 360 degrees of rotation with locking
fasteners. Various cable finishes, sleeve options, and canopy
colors offer options to match almost any space.
Rotational Arm Mount (RAM): 1/2” to 5/8” diameter
aluminum arms with various knuckle options and 360 degree
rotational capacity. There are no visible fasteners. Standard
mounting uses 3-O mud rings (supplied by others) or a 1”
optional trim ring for furniture mounted applications.
Surface Mount - Wall/Side or Ceiling/Top Mount S( MS or
SMT): Fixtures mount directly to the surface. Ceiling or Wall
Mount specification denotes the power feed hole location(s).
Optional stand-offs allow for fixtures to be mounted from 1/2”
to 12” as well as custom lengths if needed.
Asymmetric Suspension Mount (ASM and ASM-R): A unique
configuration wherein the fixture is balanced from an
off-center mounting point creating a dynamic aesthetic. This
mounting option also allows integral ballast options on the “1”
series fixtures with standard T5 lamps. Static and rotational
options lend to fixture versatility.
CU STO M:
We take pride in not only offering creative options, aesthetic
appearances, and finishes, but we are also more than willing to
accommodate any creative notions you might have. Our
experience in fixture design, engineering, and manufacturing
will ensure your expectations are met or exceeded. Please
contact the factory with any questions about our processes or
to have us help design a fixture tailored for your specific needs
and project requirements.
P H O T O M E T R I C D ATA
90.0
0
83
80.0
166
70.0
249
60.0
332
50.0
415
498
40.0
581
663
30.0
746
0.0
10.0
Oxygen 3: (1x) 4’ 28W T5
20.0
T5/T5HO Fixture Efficacy: 78%
Fixture Properties:
4’ Lamp
Clear Frost (CF) lens
Specular reflector
28w T5 Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
535
18.5
23.4
0-40
879
30.3
38.5
0-60
1586
54.7
69.4
0-90
2286
78.8
100.0
54w T5HO Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
919
18.4
23.3
0-40
1512
30.2
38.4
0-60
2732
54.6
69.3
0-90
3941
78.8
100.0
90.0
0
80.0
137
70.0
275
60.0
412
550
50.0
687
825
40.0
962
1099
30.0
20.0
0.0
Oxygen 3: (1x) 4’ 54W T5HO
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
10.0
O3-0813
4
P H O T O M E T R I C D ATA ( C O N T I N U E D )
90.0
0
130
80.0
261
70.0
391
60.0
521
50.0
652
782
40.0
913
1043
30.0
1173
0.0
10.0
Oxygen 3: (2x) 4’ 28W T5
20.0
2xT5/T5HO Fixture Efficacy: 67%
Fixture Properties:
4’ Lamp
Clear Frost (CF) lens
Specular reflector
28w T5 Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
894
15.4
23.1
0-40
1473
25.4
38.0
0-60
2674
46.2
68.9
0-90
3879
67.0
100.0
54w T5HO Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
1535
15.5
23.0
0-40
2531
25.3
37.8
0-60
4606
46.2
68.9
0-90
6687
67.0
100.0
90.0
0
80.0
227
70.0
454
60.0
681
908
50.0
1135
1362
40.0
1589
1816
30.0
20.0
10.0
0.0
Oxygen 3: (2x) 4’ 54W T5HO
T8
P H O T O M E T R I C D ATA
0
90.0
74
80.0
148
70.0
221
60.0
295
50.0
369
443
40.0
516
590
30.0
664
0.0
10.0
Oxygen 3: (1x) 4’ 32W T8
20.0
1x32W T8 Fixture Efficacy: 73%
2x32W T8 Fixture Efficacy: 50%
Fixture Properties:
4’ Lamp
Clear Frost (CF) lens
Specular reflector
1x32w T8 Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
494
17.0
23.1
0-40
813
28.0
38.0
0-60
1470
50.7
68.8
0-90
2136
73.6
100.0
2x32w T8 Zonal Lumen Summary
Zone Lumens
%Lamp
%Fixt.
0-30
681
11.7
23.1
0-40
1123
19.4
38.2
0-60
2029
35.0
69.0
0-90
2942
50.7
100.0
90.0
0
80.0
99
70.0
199
60.0
298
398
50.0
497
597
40.0
696
795
30.0
895
20.0
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
10.0
0.0
Oxygen 3: (2x) 4’ 32W T8
O3-0813
O.1
OPTIONS GUIDE
GENERAL OPTIONS*
*NOT ALL OPTIONS ARE AVAILABLE WITH EVERY FIXTURE
*NOT ALL OPTIONS SHOWN
M O UNT IN G OPTI ONS
Cable Suspended (CS)
1/16” aircraft cable suspension system. Fixtures can be static down-lights: Direct, static up-lights:
Indirect, or Rotational (see CSR below). Standard and custom power cord finishes, sleeve options,
and canopy colors offer options to match almost any space. Stainless steel cables come in various
lenghts (4’ is standard) and are field adjustable.
Cable Suspended Rotational (CS-R)
Using a similar setup to the Cable Suspended system above, the Cable Suspended - Rotational
system has 360 degree rotational capcity with mechanical fasteners to lock fixtures in place if
desired. This system offers incredible flexibility, light direction control, and a dynamic aesthetic.
Rotational Arm Mount (RAM)
This system uses 1/2” to 5/8” diameter aluminum arms and subtle details in combination with
360° rotational capacity to create some of the most versatile linear fixtures in the architectural
market. Standard mounting uses 3-O mud rings (supplied by others) or a 1” optional trim ring for
furniture mounted applications. Engineered with no visible fasteners, smooth rotation, and
mechanical locking, the RAM system reveals an impressive aesthetic with exceptional versatility.
Surface Mount (SM)
(Ceiling Mount or Wall Mount - CM or WM): Fixtures mount directly to the surface. Ceiling or Wall
Mount specification denotes the power feed hole location(s). Optional stand-offs allow for
fixtures to be mounted from 1/2” to 12” as well as custom lengths if needed.
Asymmetric Mount (ASM)
A unique configuration wherein the fixture is balanced from an off-center mounting point creating
a dynamic aesthetic. This mounting option also allows some integral ballast options on the “1”
series fixtures with standard T5 lamps. Direct, indirect, or rotational options round out this creative
mounting option.
CONT I N U O U S R U N O PTIO N S
Continuous runs are available with all fixtures and have several connection
options. Single Seam continuous run options offer smooth section
transitions while Component Seams lend to a more dramatic visual
statement. The 360 (degree symbol) Rotational option enables individual
sections to rotate independently of each other, which offers adjustable
asymmetric light distribution capacity along with striking appearances such
as alternating up/down fixtures or spiral transitions. The flexibility within
the rotational option makes for infinite design and functional possibilities.
Continuous Run
Single Seam
Continuous Run
Component Seam
COLO R A N D F I N I S H O PTIO N S
Specular
Satin White
Power coat
Continuous Run
Rotational
(Spiral effect)
F INISH CONF IGU R ATIONS
Custom Finish examples*
Satin Clear
Anodizing
Continuous Run
Rotational
Gunmetal
*Custom
Finishes
Nickel
Plating
Tl2
Standard Finishes
Satin Clear anodizing and Satin White are standard finishes.
Our Satin White is a semi-matte powder coating finish with a
subtle, rich luster. Numerous custom anodizing and powder
coated finishes are available as well. If you have a particular
color/finish treatment in mind, please contact the factory and
we will do our best to accommodate your project needs.
Standard finish configurations are Satin Clear (SC) or Satin
White (SW) housings with Machined Finish (MF) machined
components (end caps, knuckles, cover plates, etc.). The
incredibly clean detail within all of the machined
components lends to an incredibly high end aesthetic with a
two tone finish.
Matte
Black
RAL
Colors
Bronze
Color
Anodize
Color
Powder
coat
Brushed
*RAL and Custom Finishes may involve additional costs and may have fixture length restrictions.
Please consult the factory with any questions or for specific finish information.
Thallium 2 (Tl2), Cable Suspended Rotational with two-tone finish:
Satin Clear housing and Machined
Finish components.
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
Options-0813
O2
Oxygen 2 (O2), Rotational Arm
Mount system with single tone
finish: Satin Clear housing and Satin
Clear components.
OPTIONS GUIDE
O.2
GENERAL OPTIONS*
(continued)
*NOT ALL OPTIONS ARE AVAILABLE WITH EVERY FIXTURE
*NOT ALL OPTIONS SHOWN
KN U C K LE O P T I O NS
Almost all Lumium fixtures have mounting options with rotational
capacity. Flat knuckles are standard and require no change to any RAM or
CS-R specification. Concave and Convex knuckles are optional and can be
specified under the “Options/Customization”. Use the annotations listed
to the right. Other custom options are available such as larger knuckles to
match a fixture’s size or custom shapes if a specific aesthetic is destired.
Consult factory with any questions or further customization requests.
Tl1
Flat Knuckle
(standard)
Thallium 1 - Rotational Arm Mount
Standard Flat Knuckle
Concave Knuckle (CCK)
(optional)
O2 with matching knuckle size
2” or 3” (or other diameter)
knuckle - works well matching
fixtures in the Oxygen series
Convex Knuckle (CXK)
(optional)
N2 with custom square knuckle
Square Knuckle
(Custom)
Custom
limited only by one’s imagination
Trim Ring (TR)
1-1/4” diameter trim ring
Can be used in applications such
as desk mounting
Custom
Your imagination is the catalyst
for creativity
CO VE R P LAT E O P T IO N S
Cover plates are standard for
Rotational Arm Mounting (RAM)
systems. Standard options are Flat
(FT), Curved (CV), or Trim Ring (TR).
With certain applications, cover
plates or trim rings may not be
necessary. Contact factory with
questions or for more information.
Custom cover plates are also
available. if a certain aesthetic is
desired, please contact the factory to
review any concepts and we will do
our best to bring your vision to life.
Lightstream is our unique 1/16”
aperture lens that creates a striking
light accent. This design element is
inherent to the Radium2 (Ra2) and
Rubidium2 (Rb2) fixtures and can be
specified as an option on the
Thallium2 (Tl2) and Trinium2 (Tr2)
fixtures. (Note: using this option on
the Thallium2 eliminates the
integral ballast option.)
Clear Frost (CF) or White Frost (WF)
are standard, but colored gels can
be utilized to create custom color
Lightstream accents. In addition,
matching or two-tone metal accents
can be used in lieu of an emissive
lens. Please contact the factory or
your local rep agency with any
questions, color requests, or for
specification assistance.
Flat (CPFT)
Flat 4" diameter cover plate
for use with a 3-O mud ring
Curved (CPCV)
Curved 4" diameter Cover plate
for use with a 3-O mud ring
Rb 2
Ra 2
R a 2- C S - R
Tr2
Custom gel colors and other
options are available. Please
contact the factory with questions
or specific requests.
Tl2
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
Options-0813
OPTIONS GUIDE
O.3
GENERAL OPTIONS*
(continued)
*NOT ALL OPTIONS ARE AVAILABLE WITH EVERY FIXTURE
*NOT ALL OPTIONS SHOWN
C A N O PY O P T I O NS
STAN DARD
MAC H I N E D O PT I O N S
Canopies have several standard options as well as custom options to suit
various environment aesthetics. The standard cable suspension system has 5”
Satin White canopies. However, other standard options include a 2” non-power feed canopy option as well as no canopy at all. Both of these include a 5”
diameter power feed canopy.
Machined canopies are 4” in diameter and can be anodized as well as powder
caoted to match a desired color or they can be left with a mill finish for a more
striking look. Similar non-power feed options are available with this aesthetic
as well. These options do carry a higher cost than standard canopies, but also
have an impressive appearance.
55
44
55 - 5” diameter power feed canopy and 5” diameter non-power feed canopy.
Most common canopy layout. Creates a consistent ceiling aesthetic.
44
- 4” diameter machined power feed canopy and 4” diameter machined
on-power feed canopy. Offers a consistent ceiling aesthetic with slightly smaller
machined canopies. Mill, anodized, and powder coat finishes available.
52
41
52 - 5” diameter power feed canopy and 2” diameter non-power feed canopy.
For a more minimal ceiling treatment while maintaining the ability to cover up
mistakes. Requires a 1/4-20 stud securely fastened to ceiling.
41 - 4” diameter machined power feed canopy and 1-1/4” diameter machined
non-power feed canopy. For a more minimal ceiling treatment while maintaining
the ability to cover up mistakes. Requires a 1/4-20 stud securely fastened to ceiling.
Mill, anodized, and powder coat finishes available.
50
40
50
- 5” diameter power feed canopy and no canopy on the non-power feed side.
Minimal aesthetic. Requires a 1/4-20 stud securely attached to ceiling. Works well
with conintuous runs where the power can be carried inside the fixture.
40 - 4” diameter machined power feed canopy and no canopy on the non-power
feed side. Minimal aesthetic. Requires a 1/4-20 stud securely attached to ceiling.
Works well with conintuous runs where the power can be carried inside the fixture.
Mill, anodized, and powder coat finishes available.
CU S TO M C A N O P IE S
Completely custom canopies can be
ordered. These options are an upgrade,
but can look spectaculare in certain
applications. Contact the factory with all
custom requests or with any questions.
Custom Anodize
(Machined Canopies only)
Custom Powder Coat
Custom Shapes
LENS OPTIONS
Lumium has developed a unique Clear Frost (CF) polymer
composite that maintains superb lumen transmission
while limiting lamp imaging. White Frost (WF) lenses
diminish and often eliminate lamp imaging while
sacrificing only slightly reduced fixture efficacy. A choice
of Clear Frost or White Frost lenses are available with all
Lumium fixtures.
Custom lenses are also available. Consult factory for all
custom requests or with any questions.
Clear Frost (CF)
Excellent light transmission
Reduced lamp image
White Frost (WF)
Minimal to no lamp image
Slightly reduced efficacy
Lumium Lighting, LLC | 3820 Oceanic Dr., Suite 306, Oceanside, CA 92056 | Phone: 760.757.2530 | Fax: 760.283.2333 | www.lumiumlighting.com
While we always strive to ensure all website content and product information is current, Lumium Lighting reserves the right to change specifications without notice.
2012 Lumium Lighting, LLC - All rights reserved.
Options-0813
Custom
Custom colors and lens styles
available - Consult factory
Download