STATEMENT OF QUALIFICATIONS Title: CITY STREAMFLOW/WATER LEVEL STATION UPGRADES Reference No.: 1220-50-02-09 RDO v: Date: July 28, 2009 SOQ No. 1220-50-02-09 CITY OF SURREY PRE-QUALIFICATION OF BUSINESSES CITY STREAMFLOW/WATER LEVEL STATION UPGRADES Hydrometric Station Upgrades REFERENCE No. 1220-50-02-09 The City of Surrey invites submissions for pre-qualification of businesses for the supply and installation of 17 streamflow stations throughout the City. Since 1996 the City of Surrey has been operating 17 streamflow stations throughout the City. Many of these sites have been operating for over 10 years, and are starting to show signs of wear and intermittent data loss. This is due to old loggers and/or sensors that require replacement. In order to maintain consistent collection of accurate and reliable data, the City has developed an improvement plan for all of its existing streamflow stations. The improvement plan consists of physical site work and equipment upgrades for all streamflow stations throughout the City. Physical works consist of minor repairs to kiosks. Many haps, locks, and tamper guards need to be fabricated and replaced. Equipment upgrades consist of the supply and installation of pressure transducers, stilling wells, and data loggers. Pre-qualified businesses will be invited to submit a quotation for this project, which is anticipated for August 2009. The approximate schedule for the works may run from September through November of 2009. These works will be bid as one project. Interested firms must demonstrate their ability to achieve a high standard of quality in the supply and installation of projects of similar nature, size, and complexity. All business pre-qualification statements marked “Statement of Qualifications – City Streamflow/Water Level Station Upgrades Reference No. 1220-50-02-09”, Confidential – Do Not Open, will be received at City of Surrey, Purchasing Department, Attention: Manager, Purchasing & Payments, 6645 – 148th Street, Surrey, B.C. V3S 3C7, not later than 4:00 p.m. (local time), on Wednesday, August 26, 2009. All inquiries shall be directed to Ms. Violet McGregor, Manager Purchasing & Payments, 6645 – 148th Street, Surrey, B.C. V3S 3C7, Phone: 604-590-7274, Fax: 604-599-0956, e-mail: purchasing@surrey.ca Submissions will be evaluated based on the Respondents’ (and their subcontractors) qualifications and track record, recent experience with similar City Streamflow/Water Level Station Upgrades, Hydrometric Station Upgrades, demonstrated ability to complete the project within the proposed schedule, as well as any other any factors the City deems to be relevant to the project success. The City of Surrey reserves the right to reject any or all statement of qualifications, and to waive informalities in any or all submissions. SOQ No. 1220-50-02-09 1 STATEMENT OF QUALIFICATIONS – GENERAL REQUIREMENTS 1. INTRODUCTION 1.1 Purpose You are invited by the City of Surrey to submit an expression of interest for prequalification of businesses for the supply and installation of streamflow stations in the City of Surrey. The scope of works is outlined in Schedule A, for each streamflow station. Please refer to the attached map for the locations of each station. 2. INSTRUCTIONS TO RESPONDENTS 2.1 Closing Time and Address For Statement of Qualification Delivery All pre-qualification statements must be received by the office of: City of Surrey - Purchasing Attn: Manager, Purchasing & Payments at Address: 6645 – 148th Street Surrey, British Columbia V3S 3C7 on or before the following date and time (the “Closing Time”): Time: 4:00p.m. local time Date: August 26, 2009. Submissions by fax [or email] will not be accepted. 2.2 Inquiries All inquiries related to this SOQ should be directed in writing to the person named below (the "City Representative"). Information obtained from any person or source other than the City Representative may not be relied upon. Violet McGregor, Manager, Purchasing & Payments Address: 6645 – 148 Street, Surrey, BC, V3S 3C7 Phone: 604-590-7274 Fax: 604-599-0956 Email: purchasing@surrey.ca Inquiries should be made no later than seven (7) days before Closing Time. The City reserves the right not to respond to inquiries made within seven (7) days of the Closing Time. Inquiries and responses will be recorded and may be distributed to all respondents at the discretion of the City. SOQ No. 1220-50-02-09 2 3. STATEMENT OF QUALIFICATIONS FORM AND CONTENTS 3.1 Package Statement of Qualifications should be in a sealed package, marked on the outside with the respondent's name, title of the Project and reference number. 3.2 Form of Statement of Qualifications Each Business submission must complete the “City of Surrey Qualification Statement” form and resumes of the senior personnel for the company who are proposed to manage this project. All submissions received in accordance with the foregoing will be reviewed, and the prequalification of businesses shall be solely at the discretion of the City of Surrey. Businesses with unsettled legal disputes with the City will not be considered. The companies submitting for pre-qualification will be notified if they have qualified for the tendering phase of this project. The “Qualification Statement” may be supplemented by additional information as the business sees fit. The submission shall confirm the financial, staff, and equipment supply capabilities of the Business. Adequate bonding and insurance will be required for this project. The submission shall outline demonstrated expertise and experience in the areas described in the scope of work complete with current and past project locations and complete references for those projects. The City reserves the right to review similar works completed by your business that may or may not appear in your references. 3.3 Signature The legal name of the person or firm submitting the statement of qualifications should be inserted in qualification statement form. The statement of qualifications should be signed by a person authorized to sign on behalf of the respondent and include the following: (a) (b) (c) If the respondent is a corporation then the full name of the corporation should be included, together with the names of authorized signatories. The statement of qualifications should be executed by all of the authorized signatories or by one or more of them provided that a copy of the corporate resolution authorizing those persons to execute the statement of qualifications on behalf of the corporation is submitted; If the respondent is a partnership or joint venture then the name of the partnership or joint venture and the name of each partner or joint venturer should be included, and each partner or joint venturer should sign personally (or, if one or more person(s) have signing authority for the partnership or joint venture, the partnership or joint venture should provide evidence to the satisfaction of the City that the person(s) signing have signing authority for the partnership or joint venture). If a partner or joint venturer is a corporation then such corporation should sign as indicated in subsection (a) above; or If the respondent is an individual, including a sole proprietorship, the name of the individual should be included. SOQ No. 1220-50-02-09 3 4. GENERAL CONDITIONS 4.1 No City Obligation This SOQ is not a tender and does not commit the City in any way to select a preferred respondent(s), or to proceed to negotiations for an agreement, or to award any agreement. The City reserves the complete right to, at any time, reject all statement of qualifications, and to terminate this SOQ process. 4.2 Respondent's Expenses Respondent’s are solely responsible for their own expenses in preparing and submitting a statement of qualifications, and for any meetings, negotiations or discussions with the City or its representatives and consultants, relating to or arising from this SOQ. The City and its representatives, agents, consultants and advisors will not be liable to any respondent for any claims, whether for costs, expenses, losses or damages, or loss of anticipated profits, or for any other matter whatsoever, incurred by the respondent in preparing and submitting a statement of qualifications, or participating in negotiations for an agreement, or other activity related to or arising out of this SOQ. 4.3 No Agreement By submitting a statement of qualifications and participating in the process as outlined in this SOQ, respondents expressly agree that no agreement of any kind is formed under, or arises from this SOQ prior to the signing of a formal written agreement. 4.4 Conflict of Interest A respondent shall disclose in its statement of qualifications any actual or potential conflicts of interest and existing business relationships it may have with the City, its elected or appointed officials or employees. The City may rely on such disclosure. 4.5 Solicitation of Council Members and City Staff Respondents and their agents will not contact any member of the City Council or City staff with respect to this SOQ, other than the City Representative, at any time prior to the award of an agreement or the cancellation of this SOQ. 4.6 Confidentiality All submissions become the property of the City and will not be returned to the respondent. All submissions will be held in confidence by the City unless otherwise required by law. Respondents should be aware the City is a "public body" defined by and subject to the Freedom of Information and Protection of Privacy Act of British Columbia. SOQ No. 1220-50-02-09 4 SCHEDULE A - SCOPE OF WORKS Station Archibald Creek at 142 Street Bear Creek at King George Highway Chantrell Creek at 32 Avenue Elgin Creek at 32 Avenue Latimer Creek at 88 Avenue Latimer Creek at Harvie Road Little Campbell Creek at 12 Avenue Year of Site Existing Sensor Commissioning Type 1996 1996 1999 1997 1997 2001 2000 SOQ No. 1220-50-02-09 Pressure Transducer Work Program - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer in existing stilling well - Supply and install new Telog 3307A with telephone connection Bubbler - Supply and install new 0.075% accuracy Endress and Hauser Deltabar S PMD 75 differential Pressure Transducer - Supply and install new Telog R-3307A with cellular connection - Supply and install rock bolt to anchor line to prevent possible vandalism in high traffic area. Bubbler - Supply and install new kiosk hinges. - Supply and Install new 0.075% accuracy Endress and Hauser Deltabar S PMD 75 differential Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Bubbler - Supply and install second hasp and lock to kiosk. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Pressure Transducer - Supply and install new PVC stilling well with metal version fixed to sac-crete bank for stability. - Install existing staff gauge deeper into ground with heavy tools (presence of rocks). - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Bubbler - Supply and install new bottom hasp and lock on kiosk. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Bubbler - Re-locate sensor due to presence of standing wave nearby. - Re-locate staff gauge to new sensor location. - High vandalism probability. Use sealtight cable to reduce likelihood of vandalism to PT cable. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection 5 SCHEDULE A - SCOPE OF WORKS (CONT’D) Site Name MahoodCreek at 144 Street Morgan Creek at 160 Street North Creek at Fraser Highway Nicomekl Ditch Quibble Creek at 88 Avenue Serpentine River at 104 Avenue Serpentine River at 168 Street Year of Site Existing Sensor Commissioning Type Work Program Float Weight System - Supply and Install improved tamper guard. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Pressure Transducer - Supply and install a second hasp and lock to kiosk. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection 1996 Pressure Transducer - Supply and install new tamper guard. - Repair cables connected to stilling well. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and install new Unidata Neon Logger - Terrestrial Model - Supply and install new YSI 6820 V2/6920 V2 WQ Sonde 2001 Thalimedes Float Weight System - Supply and install staff gauge. - Supply and install newTelog RU33 with Integrated 0.25% Accuracy Pressure Transducer with cellular connection with battery extending case 1997 1996 1996 1996 1997 SOQ No. 1220-50-02-09 Bubbler - Supply and install second hasp and lock to kiosk. - Supply and install new staff gauge - Supply and install new 0.075% accuracy Endress and Hauser Deltabar S PMD 75 differential Pressure Transducer - Supply and install new Telog 3307A with telephone connection Pressure Transducer - Relocate staff gauge and new sensor for easier access - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection Bubbler - Supply and Install second hasp and lock to kiosk. - Move/reinforce staff gauge mounting. - Relocate new sensor location to void effects of heavy silting. - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer - Supply and Install new Telog R-3307A with cellular connection 6 SCHEDULE A - SCOPE OF WORKS (CONT’D) - Supply and Install new hydrometric station kiosk on upstream side of new bridge. - Supply and install new Radar [Siemens SITRANS probe LR] - Supply and Install new Telog R-3307A with cellular connection Serpentine River at Highway 10 To be reinstalled on new bridge N/A Serpentine Sea Dam 1998 Float Weight System - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer Nicomekl Sea Dam 1998 Float Weight System - Supply and install new 0.05% accuracy KPSI 343 Pressure Transducer Previous experience and references related to these types of work will be the most important aspect of the pre-qualification evaluation. Businesses are asked to clearly demonstrate their experience in streamflow station equipment and operation. SOQ No. 1220-50-02-09 7 SCHEDULE B - QUALIFICATION STATEMENT REFERENCE No. 1220-5-02-09 PROJECT: CITY STREAMFLOW/WATER LEVEL STATION UPGRADES A completed qualification statement is required in advance of invitation to Tender in order to establish whether the Company possesses the capacity, skill and integrity necessary for the faithful performance of the work. A. COMPANY PROFILE 1. Full Name of Company 2. Address 3. Corporation 4. If Corporation/Partnership, year incorporated/organized: 19__ 5. Names and addresses of President, Vice-President(s)/Partners: 6. Number of years organization has been in business in British Columbia: _________ 7. Approximate total volume of related work for the last five years: 8. Partnership 20__________ $ 20__________ $ 20__________ $ 20__________ $ 20__________ $ Individual Number of permanent staff: _________________________________ Number of seasonal staff: _________________________________ SOQ No. 1220-50-02-09 8 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) 9. List of related experience of the principal individuals in the company’s organization. Present Position Years of Experience Client Reference Individual’s Name 10. Financial References: Bank Bank Name: Branch: Contact Person(s): Phone No.: Fax No. Bonding Bonding Company: Limit: $ Contact Person(s): Phone No.: Fax No. Insurance Insurance Company: Liability Policy Limit: $ Contact Person(s): Phone No.: SOQ No. 1220-50-02-09 Fax No. 9 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) B. LIST OF PREVIOUS CONTRACTS & RELATED REFERENCES 1. List of similar projects completed by or currently undergoing by the Business in the past five years: 2. The Business shall list references which have been involved with the company on the project, specifically streamflow station projects. SOQ No. 1220-50-02-09 10 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) PROJECT #1 TITLE: __________________________________________ PROJECT VALUE: _____________ Description: Project Manager: Superintendent: Location: Owner : Date of Completion: Contact: Phone: Consultant: Contact: Phone: Reference #1 Refer to: Phone: Fax: Phone: Fax: Phone: Fax: Details: Reference #2 Refer to: Details: Reference #3 Refer to: Details: SOQ No. 1220-50-02-09 11 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) PROJECT #2 TITLE: __________________________________________ PROJECT VALUE: _____________ Description: Project Manager: Superintendent: Location: Owner : Date of Completion: Contact: Phone: Consultant: Contact: Phone: Reference #1 Refer to: Phone: Fax: Phone: Fax: Phone: Fax: Details: Reference #2 Refer to: Details: Reference #3 Refer to: Details: SOQ No. 1220-50-02-09 12 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) PROJECT #3 TITLE: __________________________________________ PROJECT VALUE: _____________ Description: Project Manager: Superintendent: Location: Owner : Date of Completion: Contact: Phone: Consultant: Contact: Phone: Reference #1 Refer to: Phone: Fax: Phone: Fax: Phone: Fax: Details: Reference #2 Refer to: Details: Reference #3 Refer to: Details: SOQ No. 1220-50-02-09 13 SCHEDULE B - QUALIFICATION STATEMENT (CONT’D) C. DATA ON PROJECTS TO BE TENDERED 1. Proposed Project Team: (attach resumes) Position Name of Individual Years of Experience Years with Firm Project Manager Superintendent Other Key Supervisors 2. Additional Data: The answers to the foregoing questions and all statements therein contained are true and correct. This day of , 20 Name of Company Signing Officer, Position Witness g:\wp-docs\2009\utilities\drainage & env\07061140vj.doc BRB 7/17/16 10:18 PM SOQ No. 1220-50-02-09 14 Attachments: STREAMFLOW AND WATER LEVEL STATION LOCATION MAP SOQ No. 1220-50-02-09 15 SOQ No. 1220-50-02-09 16