24th March 2003 Corporate Services PART 1 (OPEN TO THE PUBLIC) SUBJECT: ENERGY MANAGEMENT ACTIVITY DURING THE PERIOD DECEMBER 2002 TO FEBRUARY 2003. REPORT OF: DIRECTOR OF CORPORATE SERVICES FOR INFORMATION A. REPORT SUMMARY 1. PURPOSE OF REPORT: To update members on matters arising since the January 2003 meeting of the Scrutiny Committee and to report significant activities in the Energy Audit Group. 2. RECOMMENDATIONS Members are asked to note the level of savings being achieved and identified by the Group. 3. ROUTING Direct to council. 4. IMPLICATIONS 4.1 Resources (Finance/Staffing): The operation of an efficient Energy Management Group contributes to considerable Cost savings to the City Council. Competitive Tendering for energy supply will minimise the Strain on limited budgets. 4.2 Performance Review: Not Applicable. 4.3 Environmental: 4.4 Equal Opportunities: Reduction in the use of fuels, energy and water will minimise harmful effects on the environment. Not Applicable. 4.5 Community Strategy: Not Applicable. 4.6 Anti-Poverty Strategy: Not Applicable IF YOU HAVE ANY QUERIES PLEASE CONTACT Jim Gosney 793 3472 QUALITY CONTROL BACKGROUND DOCUMENTS Report Prepared by Jim Gosney 793 3472 Checked by Donald Simpson 793 3290 Corporate Services (Finance), Salford Civic Centre, Chorley Road, Swinton. M27 5AW REPORT DETAILS 5. ENERGY MANAGEMENT Activities undertaken during the period December 2002 to March 2003 include the following: Progress of the energy audit plan The levels of energy savings achieved. Recently published White Paper on Energy 6. PURCHASE OF PUBLIC LIGHTING ELECTRICITY We are pleased to report that savings of £38,856 (9%) have been achieved for a two-year period, through the competitive tendering of the public lighting electricity contract. This contract also includes provision for 10% of the electricity to be supplied via “Green” energy resources. 7. ELECTRICITY PURCHASING TO COUNCIL PREMISES The competitive tendering for 15 of the council’s large sites has now been completed. Savings of approximately £8,353 will be achieved across these sites, for a one-year period. We are also pleased to advise that three of these sites, Civic Centre, Turnpike House and Clarendon Recreation Centre will be supplied on a “Green” energy contract. We are also pleased to report that another 30 sites have been included on our small site contract with Scottish Power. Savings across the sites will amount to £11,393.88. 8. ENERGY SAVINGS ACHIEVED Implemented Energy Savings, through purchasing, tariff analysis and water audits amount to £151,287.41 for the year to date. Refunds for the amount of £183,168.65 have also been achieved and cheques from the various suppliers received. A number of energy audits at the following premises have also been conducted. The summaries are attached in Appendix A. Premise Name Potential Savings (Annual) St Philip’s R C Primary Clarendon Recreation Centre Pendlebury Recreation Centre Broughton Pool Eccles Recreation Centre Worsley Pool Irlam Pool Total £1,107 £5,500 £4,130 £9,785 £5,645 £13,870 £ 3,995 £44,032 CO2 83.1 62.1 101.7 83.9 210.6 56.1 597.5 9. ENVIRONMENTAL BENEFITS OF ENERGY AUDIT ACTIVITIES Premises Seedley Primary School Langworthy Rd Primary School St Pauls C E Primary School St Marks R C Primary School Monton Green Primary School Libraries Christ The King RC Primary St Gilberts RC Primary Lower Kersal PS Lark Hill Primary St Lukes Primary St Boniface RC Primary Civic Centre Canon Williamson High School St Ambrose Barlow High School Irlam Primary School Broughton Resource Centre Worsley Courthouse Ingleside St Philip’s RC Primary Clarendon Recreation Centre Pendlebury Recreation Centre Broughton Pool Eccles Recreation Centre Worsley Pool Irlam Pool Date Potential Report Savings Issued (Annual) 01/03/01 £4,646 26/03/01 £2,940 01/06/01 £3,350 18/06/01 £3,395 27/06/01 £2,480 03/08/01 £23,629 10/08/01 £3,608 27/03/02 £1,843 22/05/02 £9,512 23/05/02 £5,365 23/05/02 £2,040 23/05/02 £1,360 14/08/02 £4,870 11/07/02 £3,665 11/07/02 £4,955 18/07/02 £1,905 09/09/02 £4,217 21/10/02 £11,104 09/12/02 £1,880 06/02/03 £1,107 07/02/03 £5,500 07/02/03 £4,130 07/02/03 £9,785 07/02/03 £5,645 19/02/03 £13,870 19/02/03 £3,995 £140,796 10 CO2 Reduction (Tonnes) 9.29 5.88 6.70 6.8 4.96 47.3 7.2 36.9 11.9 10.73 4.08 2.72 61.0 52.0 52.0 32.8 83.1 62.1 101.7 83.9 210.6 56.1 949.76 ENERGY WHITE PAPER The energy white paper and what Government expects in future from local authorities, a brief synopsis: On the 24th February 2003 the DTI published the energy white paper “Our energy future creating a low carbon economy”. This addressed three challenges of energy policy: environmental protection, to reduce climate change and emissions of greenhouse gases, the decline of the UK's indigenous energy supplies and the future dependence on imported energy also the need to update and adapt much of the UK's energy infrastructure to accommodate more renewables and small-scale de-centralised power generation. To address these challenges the new energy policy has four goals: To put the UK on a path to cut carbon dioxide emissions by some 60% by about 2050, with real progress by 2020; to maintain the reliability of energy supplies; to promote competitive markets in the UK and beyond, helping to raise the rate of sustainable economic growth and improve the UK's productivity; to ensure that every home is adequately and affordably heated. Government expect the delivery of the energy policy to be achieved through partnership with stakeholders, including local authorities, regional chambers and regional development agencies who make decisions that are vital for energy policy (for example on planning, regeneration and development, procurement, housing, transport and sustainable development). The future energy system will also require greater involvement from local communities. From 2002/2003 local authorities will be required to benchmark their energy use in operational properties and street lighting and will have to set local improvement targets from 2003/2004. Local authorities will have a growing role as community leaders: There will be a greater emphasis on developing and implementing both local and regional strategic approaches to delivering the Government's energy objectives. Regional targets for renewable and energy efficiency will be negotiated and an action plan will be set out showing how regional bodies and local authorities intend to help deliver objectives on energy through their various roles and functions The Government will consult shortly on detailed proposals for developing this strategic approach. Regional assemblies will take responsibility for leading the work where they are established. RDA's will be strongly encouraged to play a key role in delivery of initiatives at regional level. In the longer term the Government want to see local authorities and regional bodies take a pro-active role. The Sustainable Energy Policy Network will have a remit to develop the partnership with local and regional bodies on energy issues. In addition the Government will: establish a new beacon councils theme on sustainable energy to promote innovative local approaches on generation and demand-side measures; promote energy efficiency and the roll-out of new technologies as areas in which local authorities can consider Local Public Service Agreements; urge local authorities to give energy issues priority at a strategic level through their Community Plans and Housing Strategies, consistent with the new strategic approach to be developed at regional level; encourage local authorities to take the lead, acting as catalysts for change, developing and facilitating cross-sectoral partnerships and providing advice and encouragement; review existing guidance to Energy Conservation Authorities on complying with the requirements of the Home Energy Conservation Act; consider with the Local Government Association (LGA) whether at the next review to include energy as a shared central-local priority; and consult on arrangement to collect and make available data on the pattern of energy usage in local areas, to enable local authorities and regional bodies to target activity more effectively. ' APPENDIX A RECREATION CENTRE ENERGY AUDITS At the request of the Education and Leisure Directorate, energy audits have been conducted at the recreation centres/pools. CLARENDON RECREATION CENTRE Recommendation £ Saving KWh or m3 CO2 Pay back Years £ Cost tonne 1. Pool lights – switch off on no occupancy £120 3,200 1.4 0 Immediate 2. Pool Water – increase evaporative loss claim from 4% to 12% £120 n/a 0 0 Immediate 3. Fluorescent Lights – use T8 tubes in place of T12 (when stock runs out) £70 1,860 0.8 0 Immediate 4. Coke and Lucozade canned drink machines – time control 75 1,400 1.2 80 1.1 5. Café Lighting – convert from tungsten spot to compact fluorescent spot lamps 85 2,320 1.0 180 2.1 6. Sunbed Room lights – add switch plate presence sensors to both rooms 45 1,200 0.5 100 2.2 7. Pool ventilation plant – replacement with desiccant wheel plant to recover 90% of the extract air heat. 4,985 280,000 78.2 55,000 11.0 Summary 1,400 £ Saving of savings CO2 Pay back Years £ Cost tonne No Cost - Immediate payback £310 2.2 £0 0 Low Cost - Rapid payback investment £205 2.7 £360 1.8 High Cost - Longer payback investment £4,985 78.2 £55,000 11.0 Totals £5,500 83.1 £55,360 10.1 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 PENDLEBURY RECREATION CENTRE Recommendation £ Saving Main boiler and Pool ventilation plant – reset operating times to save 11.5 hours per week £465 9. Pool Water – evaporative loss claim £150 10. 1 off Canned drink vending machines – time control 11. 12. 8. KWh or m3 CO2 Pay back Years £ Cost tonne 7.1 0 Immediate n/a 0 0 Immediate £45 700 0.6 £40 0.9 Sports dry change and administration area boiler plant – BMS control £530 28,000 8.3 £2,200 4.2 Replacement boiler plant £2,940 165,000 46.1 £65,000 22.1 Summary 1,200 23,400 £ Saving CO2 of savings Pay back Years £ Cost tonne No Cost - Immediate payback £615 0 £0 0 Low Cost - Rapid payback investment £575 8.9 £2,240 3.9 High Cost - Longer payback investment £2,940 46.1 £65,000 22.1 Totals £4,130 62.1 £67,240 16.3 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 BROUGHTON POOL Recommendation £ Saving KWh or m3 CO2 £ Cost tonne Pay back Years 13. Pool Water – evaporative loss claim £195 n/a 0 0 Immediate 14. 2 off Canned drink vending machines – time control £90 1,400 31,400 1.2 £80 0.9 15. Boiler plant – BMS control – reset of flow temperature during quiescent periods £2,720 160,000 42.8 £8,000 2.9 16. Pool Hall – lighting replacement £320 8,000 3.4 £4,000 12.5 17. Pool hall extract air desiccant wheel heat recovery plant £6,460 380,000 102 £55,000 8.5 Summary £ Saving CO2 of savings £ Cost tonne Pay back Years No Cost - Immediate payback £195 0 £0 0 Low Cost - Rapid payback investment £3,130 47.4 £12,080 3.9 High Cost - Longer payback investment £6,460 101.7 £55,000 10.1 Totals £9,785 101.7 £67,080 6.9 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 ECCLES RECREATION CENTRE Recommendation £ Saving KWh or m3 CO2 £ Cost tonne Pay back Years 18. Sports Hall – reduce the temperature setting from 18°C to 16°C £460 28,900 7.1 0 Immediate 19. Sports Hall – reset the time control for weekend use saving 4 hours per week £185 9,600 2.7 0 Immediate 20. Pool Water – evaporative loss claim £150 n/a 0 0 Immediate 21. 5 off Canned drink vending machines – time control £220 3,500 3.0 £200 0.9 22. Boilers – BMS control £510 32,100 7.9 £1,200 2.4 23. Sports Hall – lighting control – reinstate £190 4,800 2.1 £600 3.2 24. Male change – lighting control £60 1,450 0.6 £220 3.7 25. Pool hall extract air desiccant wheel heat recovery plant £3,870 245,000 60.5 £49,600 12.8 Summary £ Saving of savings CO2 £ Cost tonne Pay back Years No Cost - Immediate payback £795 9.8 £0 0 Low Cost - Rapid payback investment £980 13.6 £2,220 2.3 High Cost - Longer payback investment £3,870 60.5 £49,600 12.8 Totals £5,645 83.9 £51,820 9.2 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 WORSLEY POOL Recommendation £ Saving KWh or m3 CO2 £ Cost tonne Pay back Years 26. Water – claim for pool surface evaporative loses from 4% to 12% £300 0 0 0 Immediate 27. Fitness Suite – use the fresh air ventilation fans instead of the air conditioners £415 3,600 5.2 0 Immediate 28. Vending machines – time control canned drink machines £90 1,400 1.2 £80 0.9 29. Main entrance doors – adjust closers, fit and draught strip £130 7,200 2.0 £350 2.7 30. Male and Female main pool change – lighting presence sensors £190 4,800 2.1 £700 3.7 31. Main pool ventilation plant replacement with a desiccant wheel plant £6,765 380,000 17.7 £80,000 11.8 32. Boiler No. 2 – replacement plus controls £3,845 216,000 105 £68,000 17.7 33. Learner pool ventilation – new plant £2,135 120,000 33.5 £75,000 35.1 Summary £ Saving of savings CO2 £ Cost tonne Pay back Years No Cost - Immediate payback £715 5.2 0 0 Low Cost - Rapid payback investment £410 5.3 £1,130 2.8 High Cost - Longer payback investment £12,475 200.1 £223,000 17.5 Totals £13,870 210.6 £224,130 16.2 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 IRLAM POOL Recommendation £ Saving KWh or m3 CO2 Pay back Years £ Cost tonne 34. Change AHU – adjust times for early weekend closing at 15:30. £365 22,000 5.7 0 immediate 35. Water – claim for pool surface evaporative loses from 4% to 12% £120 0 0 0 Immediate 36. Vending machines – time control canned drink machines £90 1,400 1.2 £80 0.9 37. Main entrance doors – adjust closers inner and outer £140 8,400 2.3 £350 2.5 38. Main pool – recovery of heat from 50% of the main pool air £2,425 146,000 38.0 £9,000 3.7 39. Main pool lighting – change to SONT £855 21,500 9.2 £8,000 9.4 Summary £ Saving CO2 of savings Pay back Years £ Cost tonne No Cost - Immediate payback £485 0 0 0 Low Cost - Rapid payback investment £230 3.4 £430 1.9 High Cost - Longer payback investment £3,280 47.0 £17,000 5.2 Totals £3,995 56.1 £17,430 4.4 Source for CO2 saving calculations: Environmental reporting Guidelines for Company Reporting on Greenhouse Gas Emissions - DEFRA August 2001 ST. PHILIP’S R C PRIMARY SCHOOL RECOMMENDATION Saving Saving M3 £ Installation Cost Payback Period 1. Installation of push taps (retro fit) 553m3 £713 £684 11 months 2. Cistern Dams 92m3 £118 £116 11 months 3. Urinal Control 214m3 £276 £145 6 months Total 859m3 £1,107 £945