Controls Southeast, Inc. Mailing: Post Office Box 7500, Charlotte, NC 28241 Shipping: 12201 Nations Ford Road, Pineville, NC 28134 www.csiheat.com Phone: Fax: 704-644-5000 704-644-5100 CONTROTRACE DATA SHEET Client Information Company: Contact Name: Phone Number: Email: Date completed: Drawings provided? Line list provided? P&ID’s provided? YES YES YES NO NO NO N/A N/A N/A Thermal Objective (Check one) 1. Maintain bulk process temperature? 2. Maintain pipe/tank/vessel wall temperature to prevent condensation? 3. Maintain above 32°F / 0°C for freeze protection? 4. CSI to recommend 5. Other: Process 6. Chemical Name: 7. Normal Operating Temperature: 8. Target Maintenance Temperature: 9. Upper Limit Temperature: 10. Lower Limit Temperature: 11. Density (ρ): 12. Viscosity (μ): 15. Process flow rate: F / F / F / F / Heating Medium 16. Media Type: Steam 17. Operating Temperature: F / 18. Operating Pressure: psig / 19. Type of steam trap to be used: Bucket 20. Maximum expected condensate return pressure: Vapor Liquid (Check one) C C C C 13. Thermal Conductivity (k): 14. Specific heat of process (Cp): Hot Oil Other: (Check one) C barg Float Disc Thermostatic Other: psig / barg (Check one) Environment/Other 21. Standard ControTrace is constructed from ASME SA-178 Gr.A carbon steel boiler tubing. (Other materials may be available.) Is this material acceptable for your application? YES NO (Check one) 22. Standard ControTrace pressure/temperature rating is 150 psig at 400F. Is this rating acceptable for your application? YES NO (Check one) 23. Is the ControTrace for Indoor or Outdoor use? Indoor Outdoor (Check one) 24. Ambient Design Temperature? F / C 25. Other comments: Rev.1 19-Feb-2010 Vessel Design (if applicable) NOTE: If the information requested below is contained in documentation submitted within the RFQ, it is not required to complete these additional fields. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. Orientation: Vertical Horizontal Outside Diameter: Wall Thickness: Seam to seam dimension: Material of construction: Head Type: Top: Bottom: Insulation type: Thickness: Insulation support and/or stiffener rings? Qty: Location: Supports and/or legs? Qty: Location: Is this a code stamped vessel? Can bosses/hanger clips be welded to the vessel? Are nozzles to be jacketed by CSI using ControHeat/ControTrace? If not, are they already jacketed? Where will installation of ControTrace take place? How is the vessel vapor space being handled? (single vent, forced air movement, nitrogen blanket, etc) What is the rate of vapor exchange in the vapor space (if applicable)? At what temperature does vapor enter the vessel (if applicable)? Additional Notes / Comments: 42. 43. 44. 45. 46. Typical Vessel Designs (Circle the design which best describes this application.) Rev.1 19-Feb-2010