ARCHITECTURE DESCRIPTION DOCUMENT FOR OTEC PROJECT Saturday, November 21, 2009 Prepared For: SYST798 Prepared By: Team 2 Pierre Cannon Sumon Nandy Amy Nandy Saturday, November 21, 2009 Table of Contents 1 2 3 4 5 6 Operational Overview ............................................................................................................................... 1 Systems Overview .................................................................................................................................... 2 Systems/Components ................................................................................................................................ 3 Interfaces ................................................................................................................................................. 11 Functional Model .................................................................................................................................... 38 Risks........................................................................................................................................................ 78 —i— Saturday, November 21, 2009 List of Figures 1 OTEC System Physical Block Diagram ................................................................................................... 4 2 Central Computer Physical Block Diagram .............................................................................................. 5 3 Operate OTEC System Enhanced FFBD ................................................................................................ 41 4 Operate OTEC System FFBD ................................................................................................................. 42 5 Operate OTEC System N2 Diagram ....................................................................................................... 42 6 Operate OTEC System IDEF0 Diagram ................................................................................................. 44 7 Control OTEC System Enhanced FFBD ................................................................................................ 45 8 Control OTEC System FFBD ................................................................................................................. 45 9 Control OTEC System N2 Diagram ....................................................................................................... 46 10 Control OTEC System IDEF0 Diagram ............................................................................................... 47 11 Generate Power Enhanced FFBD ......................................................................................................... 50 12 Generate Power FFBD .......................................................................................................................... 50 13 Generate Power N2 Diagram ................................................................................................................ 51 14 Generate Power IDEF0 Diagram .......................................................................................................... 52 15 Monitor Health Enhanced FFBD .......................................................................................................... 54 16 Monitor Health FFBD ........................................................................................................................... 54 17 Monitor Health N2 Diagram ................................................................................................................. 55 18 Monitor Health IDEF0 Diagram ........................................................................................................... 56 — ii — Saturday, November 21, 2009 List of Tables 1 1 Central Computer External I/O ............................................................................................................ 11 2 2 Cold Water Pipe External I/O .............................................................................................................. 14 3 3 Condenser External I/O........................................................................................................................ 16 4 3.1 ThermostatC External I/O ................................................................................................................. 18 5 4 Evaporator External I/O ....................................................................................................................... 18 6 4.1 ThermostatE External I/O ................................................................................................................. 20 7 5 Fluid Pump External I/O ...................................................................................................................... 20 8 5.1 Pressure Sensor External I/O ............................................................................................................ 22 9 6 Generator External I/O ......................................................................................................................... 22 10 6.1 Power Sensor External I/O .............................................................................................................. 24 11 7 Hot Water Pipe External I/O .............................................................................................................. 24 12 8 Turbine External I/O .......................................................................................................................... 26 13 8.1 Tachometer External I/O ................................................................................................................. 27 14 9 Water Pump External I/O ................................................................................................................... 27 15 9.1 Pump Power Sensor External I/O ................................................................................................... 29 16 COOL OCEAN WATER External I/O ................................................................................................. 29 17 DEEP COLD OCEAN WATER External I/O ...................................................................................... 31 18 WARM OCEAN WATER External I/O .............................................................................................. 33 19 WARM OCEAN SURFACE WATER External I/O ............................................................................ 34 20 0 Operate OTEC System Interfacing Items .......................................................................................... 40 21 1 Control OTEC System Interfacing Items ........................................................................................... 44 22 2 Generate Power Interfacing Items ...................................................................................................... 48 23 3 Monitor Health Interfacing Items ...................................................................................................... 53 24 11 Start OTEC System Interfacing Items ............................................................................................. 56 25 12 Run OTEC CPU Interfacing Items .................................................................................................. 57 26 13 Control System Interfacing Items .................................................................................................... 57 27 14 Stop OTEC System Interfacing Items .............................................................................................. 58 28 21 Pump Working Fluids Interfacing Items .......................................................................................... 59 29 22 Pump Water Interfacing Items ......................................................................................................... 60 30 23 Evaporate Working Fluid Interfacing Items .................................................................................... 62 31 24 Drive Turbine Interfacing Items ...................................................................................................... 63 32 25 Spin Generator Interfacing Items ..................................................................................................... 64 33 26 Condense Working Fluid Interfacing Items ..................................................................................... 65 34 31 Monitor Turbine Speed Interfacing Items ........................................................................................ 66 35 32 Monitor Generator Power Interfacing Items .................................................................................... 67 36 33 Monitor Condenser Temperature Interfacing Items ......................................................................... 68 37 34 Monitor Evaporator Temperature Interfacing Items ........................................................................ 69 38 35 Monitor Fluid Pressure Interfacing Items ........................................................................................ 70 39 36 Monitor Pump Power Interfacing Items ........................................................................................... 71 — iii — Saturday, November 21, 2009 1 Operational Overview This section is empty if an Architecture is not specified or the selected Architecture does not link to a toplevel Operational Node of type Operational Node. —1— Saturday, November 21, 2009 2 Systems Overview This section is empty if a primary Component is not specified. —2— Saturday, November 21, 2009 3 Systems/Components Part I - Component List 0 - OTEC System 1 - Central Computer 2 - Cold Water Pipe 3 - Condenser 3.1 - ThermostatC 4 - Evaporator 4.1 - ThermostatE 5 - Fluid Pump 5.1 - Pressure Sensor 6 - Generator 6.1 - Power Sensor 7 - Hot Water Pipe 8 - Turbine 8.1 - Tachometer 9 - Water Pump 9.1 - Pump Power Sensor COOL OCEAN WATER DEEP COLD OCEAN WATER WARM OCEAN WATER WARM OCEAN SURFACE WATER Part II - Component Definitions 0 OTEC System Built From Lower-Level Component(s): 1 Central Computer 2 Cold Water Pipe 3 Condenser 4 Evaporator 5 Fluid Pump 6 Generator 7 Hot Water Pipe 8 Turbine 9 Water Pump Joined Thru Logical Interface: Cold Water input Cool Water output Surface water input Warm Water Output —3— Saturday, November 21, 2009 3 Systems/Components 1 Central Computer nil 2 Cold Water Pipe nil 3 Condenser nil 4 Evaporator nil 5 Fluid Pump nil 6 Generator nil 7 Hot Water Pipe nil 8 Turbine nil 9 Water Pump nil Date: Thursday, October 29, 2009 Author: Number: Name: Figure 1 OTEC System Physical Block Diagram 1 Central Computer Built In Higher-Level Component(s): 0 OTEC System Built From Lower-Level Component(s): 3.1 ThermostatC 4.1 ThermostatE 5.1 Pressure Sensor 6.1 Power Sensor 8.1 Tachometer 9.1 Pump Power Sensor —4— 0 University User (University) OTEC Sys tem Saturday, November 21, 2009 3 Systems/Components 3.1 ThermostatC nil 4.1 ThermostatE nil 5.1 Pressure Sensor nil 6.1 Power Sensor nil 8.1 Tachometer nil 9.1 Pump Power Sensor nil Date: Saturday, November 21, 2009 Author: Number: Name: (University) Central Computer 1 Figure 2 Central Computer Physical Block Diagram Performs Function(s): 0 Operate OTEC System 1 Control OTEC System 3 Monitor Health 11 Start OTEC System 12 Run OTEC CPU 13 Control System 14 Stop OTEC System Exhibits Performance Objectives: S.13 Computer S.14 Processing S.15 Error Monitoring S.16 Health Monitoring S.17 Corrective Action Specified By Requirements (untyped): N.1 Command —5— University User Saturday, November 21, 2009 3 Systems/Components N.3 Monitoring and Control 2 Cold Water Pipe Built In Higher-Level Component(s): 0 OTEC System Joined To Logical Interface: Cold Water input Performs Function(s): 0 Operate OTEC System 2 Generate Power 22 Pump Water Specified By Requirements (untyped): N.4 System Lifetime Q.2 Component Lifetime Q.10 Used Water 3 Condenser Built In Higher-Level Component(s): 0 OTEC System Joined To Logical Interface: Cool Water output Performs Function(s): 0 Operate OTEC System 2 Generate Power 26 Condense Working Fluid Exhibits Performance Objectives: S.2 Heat Exchangers S.5 Component Selection Specified By Requirements (untyped): Q.10 Used Water 3.1 ThermostatC Built In Higher-Level Component(s): 1 Central Computer Performs Function(s): 33 Monitor Condenser Temperature Exhibits Performance Objectives: S.5 Component Selection S.9 Thermocouple rating 4 Evaporator Built In Higher-Level Component(s): —6— Saturday, November 21, 2009 3 Systems/Components 0 OTEC System Joined To Logical Interface: Warm Water Output Performs Function(s): 0 Operate OTEC System 2 Generate Power 23 Evaporate Working Fluid Exhibits Performance Objectives: S.2 Heat Exchangers S.5 Component Selection Specified By Requirements (untyped): Q.10 Used Water 4.1 ThermostatE Built In Higher-Level Component(s): 1 Central Computer Performs Function(s): 34 Monitor Evaporator Temperature Exhibits Performance Objectives: S.5 Component Selection S.9 Thermocouple rating 5 Fluid Pump Built In Higher-Level Component(s): 0 OTEC System Performs Function(s): 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids Specified By Requirements (untyped): N.6 Survivability N.7 Construction N.8 Maintenance of Subsystems N.9 MTTR Q.2 Component Lifetime 5.1 Pressure Sensor Built In Higher-Level Component(s): 1 Central Computer Performs Function(s): 35 Monitor Fluid Pressure Exhibits Performance Objectives: —7— Saturday, November 21, 2009 3 Systems/Components S.5 Component Selection 6 Generator Built In Higher-Level Component(s): 0 OTEC System Performs Function(s): 0 Operate OTEC System 2 Generate Power 25 Spin Generator Exhibits Performance Objectives: S.4 Generator S.5 Component Selection S.6 Voltage Regulators 6.1 Power Sensor Built In Higher-Level Component(s): 1 Central Computer Performs Function(s): 32 Monitor Generator Power Exhibits Performance Objectives: S.5 Component Selection S.10 Voltage Meters 7 Hot Water Pipe Built In Higher-Level Component(s): 0 OTEC System Joined To Logical Interface: Surface water input Performs Function(s): 0 Operate OTEC System 2 Generate Power 22 Pump Water Specified By Requirements (untyped): N.4 System Lifetime Q.2 Component Lifetime Q.10 Used Water 8 Turbine Built In Higher-Level Component(s): 0 OTEC System Performs Function(s): 0 Operate OTEC System —8— Saturday, November 21, 2009 3 Systems/Components 2 Generate Power 24 Drive Turbine Exhibits Performance Objectives: S.3 Turbine Specified By Requirements (untyped): N.4 System Lifetime N.6 Survivability N.7 Construction N.8 Maintenance of Subsystems N.9 MTTR 8.1 Tachometer Built In Higher-Level Component(s): 1 Central Computer Exhibits Performance Objectives: S.5 Component Selection S.7 Tachometer rating S.8 Tachometer status 9 Water Pump Built In Higher-Level Component(s): 0 OTEC System Performs Function(s): 0 Operate OTEC System 2 Generate Power 22 Pump Water Specified By Requirements (untyped): N.4 System Lifetime N.6 Survivability N.7 Construction N.8 Maintenance of Subsystems N.9 MTTR Q.2 Component Lifetime Q.10 Used Water 9.1 Pump Power Sensor Built In Higher-Level Component(s): 1 Central Computer Performs Function(s): 36 Monitor Pump Power Exhibits Performance Objectives: S.5 Component Selection S.10 Voltage Meters —9— Saturday, November 21, 2009 3 Systems/Components COOL OCEAN WATER Description: Cold water output Joined To Logical Interface: Cool Water output Performs Function(s): 0 Operate OTEC System 2 Generate Power 23 Evaporate Working Fluid DEEP COLD OCEAN WATER Description: Deep cold water input Joined To Logical Interface: Cold Water input Performs Function(s): 0 Operate OTEC System 2 Generate Power 23 Evaporate Working Fluid WARM OCEAN WATER Description: Warm Water Output Joined To Logical Interface: Warm Water Output Performs Function(s): 0 Operate OTEC System 2 Generate Power 23 Evaporate Working Fluid WARM OCEAN SURFACE WATER Description: Warm surface water input Joined To Logical Interface: Surface water input Performs Function(s): 0 Operate OTEC System 2 Generate Power 23 Evaporate Working Fluid — 10 — Saturday, November 21, 2009 4 Interfaces Part I - Derived Functional Interfaces Table 1 1 Central Computer External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER — 11 — Saturday, November 21, 2009 4 Interfaces Table 1 1 Central Computer External I/O Function Interface Item Interfacing Entity 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 1 Control OTEC System System Controls 2 Generate Power2 Cold Water Pipe 2 Generate Power3 Condenser 2 Generate Power4 Evaporator 2 Generate Power5 Fluid Pump 2 Generate Power6 Generator 2 Generate Power7 Hot Water Pipe 2 Generate Power8 Turbine 2 Generate Power9 Water Pump 2 Generate PowerCOOL OCEAN WATER 2 Generate PowerDEEP COLD OCEAN WATER 2 Generate PowerWARM OCEAN WATER 2 Generate PowerWARM OCEAN SURFACE WATER 21 Pump Working Fluids5 Fluid Pump 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 3 Monitor Health Data 2 Generate Power7 Hot Water Pipe 2 Generate Power2 Cold Water Pipe 2 Generate Power3 Condenser 2 Generate Power4 Evaporator 2 Generate Power5 Fluid Pump 2 Generate Power6 Generator 2 Generate Power8 Turbine 2 Generate Power9 Water Pump 2 Generate PowerCOOL OCEAN WATER 2 Generate PowerDEEP COLD — 12 — Saturday, November 21, 2009 4 Interfaces Table 1 1 Central Computer External I/O Function Interface Item Interfacing Entity OCEAN WATER 2 Generate PowerWARM OCEAN WATER 2 Generate PowerWARM OCEAN SURFACE WATER 13 Control System System Controls 2 Generate Power2 Cold Water Pipe 2 Generate Power3 Condenser 2 Generate Power4 Evaporator 2 Generate Power5 Fluid Pump 2 Generate Power6 Generator 2 Generate Power7 Hot Water Pipe 2 Generate Power8 Turbine 2 Generate Power9 Water Pump 2 Generate PowerCOOL OCEAN WATER 2 Generate PowerDEEP COLD OCEAN WATER 2 Generate PowerWARM OCEAN WATER 2 Generate PowerWARM OCEAN SURFACE WATER 21 Pump Working Fluids5 Fluid Pump 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 14 Stop OTEC System System Controls 2 Generate Power2 Cold Water Pipe 2 Generate Power3 Condenser 2 Generate Power4 Evaporator 2 Generate Power5 Fluid Pump 2 Generate Power6 Generator 2 Generate Power7 Hot Water Pipe 2 Generate Power8 Turbine 2 Generate Power9 Water Pump 2 Generate PowerCOOL OCEAN WATER 2 Generate PowerDEEP COLD OCEAN WATER — 13 — Saturday, November 21, 2009 4 Interfaces Table 1 1 Central Computer External I/O Function Interface Item Interfacing Entity 2 Generate PowerWARM OCEAN WATER 2 Generate PowerWARM OCEAN SURFACE WATER 21 Pump Working Fluids5 Fluid Pump 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump Table 2 2 Cold Water Pipe External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System1 Central Computer 0 Operate OTEC System3 Condenser — 14 — Saturday, November 21, 2009 4 Interfaces Table 2 2 Cold Water Pipe External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 22 Pump Water Cold Water 26 Condense Working Fluid3 Condenser 22 Pump Water Hot Water 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER 22 Pump Water Pump Power 36 Monitor Pump Power9.1 Pump Power Sensor 22 Pump Water Net Power 25 Spin Generator6 Generator 22 Pump Water System Controls 1 Control OTEC System1 Central Computer — 15 — Saturday, November 21, 2009 4 Interfaces Table 2 2 Cold Water Pipe External I/O Function Interface Item Interfacing Entity 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer Table 3 3 Condenser External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator — 16 — Saturday, November 21, 2009 4 Interfaces Table 3 3 Condenser External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 26 Condense Working Fluid Liquid Ammonia 21 Pump Working Fluids5 Fluid Pump 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER 26 Condense Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC 34 Monitor Evaporator Temperature4.1 ThermostatE 26 Condense Working Fluid Ammonia Steam 24 Drive Turbine8 Turbine 26 Condense Working Fluid Cold Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump — 17 — Saturday, November 21, 2009 4 Interfaces Table 4 3.1 ThermostatC External I/O Function Interface Item 33 Monitor Condenser Temperature Temperature Interfacing Entity 26 Condense Working Fluid3 Condenser 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER Table 5 4 Evaporator External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe — 18 — Saturday, November 21, 2009 4 Interfaces Table 5 4 Evaporator External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 23 Evaporate Working Fluid Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 23 Evaporate Working Fluid Steam Ammonia 24 Drive Turbine8 Turbine 23 Evaporate Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC 34 Monitor Evaporator Temperature4.1 ThermostatE 23 Evaporate Working Fluid Hot Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 23 Evaporate Working Fluid Liquid Ammonia 26 Condense Working Fluid3 Condenser — 19 — Saturday, November 21, 2009 4 Interfaces Table 6 4.1 ThermostatE External I/O Function Interface Item 34 Monitor Evaporator Temperature Temperature Interfacing Entity 26 Condense Working Fluid3 Condenser 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER Table 7 5 Fluid Pump External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe — 20 — Saturday, November 21, 2009 4 Interfaces Table 7 5 Fluid Pump External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System6 Generator 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 21 Pump Working Fluids Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 21 Pump Working Fluids Pump Power 36 Monitor Pump Power9.1 Pump Power Sensor 21 Pump Working Fluids Liquid Ammonia 26 Condense Working Fluid3 Condenser 21 Pump Working Fluids Net Power 25 Spin Generator6 Generator 21 Pump Working Fluids System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer — 21 — Saturday, November 21, 2009 4 Interfaces Table 8 5.1 Pressure Sensor External I/O Function 35 Monitor Fluid Pressure Interface Item Fluid Pressure Interfacing Entity 23 Evaporate Working FluidWARM OCEAN SURFACE WATER 21 Pump Working Fluids5 Fluid Pump 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER Table 9 6 Generator External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System7 Hot Water Pipe — 22 — Saturday, November 21, 2009 4 Interfaces Table 9 6 Generator External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 25 Spin Generator Net Power 21 Pump Working Fluids5 Fluid Pump 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 25 Spin Generator Output Power 32 Monitor Generator Power6.1 Power Sensor 25 Spin Generator Mechanical Energy 24 Drive Turbine8 Turbine — 23 — Saturday, November 21, 2009 4 Interfaces Table 10 6.1 Power Sensor External I/O Function 32 Monitor Generator Power Interface Item Output Power Interfacing Entity 25 Spin Generator6 Generator Table 11 7 Hot Water Pipe External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water — 24 — Saturday, November 21, 2009 4 Interfaces Table 11 7 Hot Water Pipe External I/O Function Interface Item Interfacing Entity Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 22 Pump Water Cold Water 26 Condense Working Fluid3 Condenser 22 Pump Water Hot Water 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER 22 Pump Water Pump Power 36 Monitor Pump Power9.1 Pump Power Sensor 22 Pump Water Net Power 25 Spin Generator6 Generator 22 Pump Water System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer — 25 — Saturday, November 21, 2009 4 Interfaces Table 12 8 Turbine External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM — 26 — Saturday, November 21, 2009 4 Interfaces Table 12 8 Turbine External I/O Function Interface Item Interfacing Entity OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 24 Drive Turbine Ammonia Steam 26 Condense Working Fluid3 Condenser 24 Drive Turbine Mechanical Energy 25 Spin Generator6 Generator 24 Drive Turbine Speed 31 Monitor Turbine Speed8.1 Tachometer 24 Drive Turbine Steam Ammonia 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER Table 13 8.1 Tachometer External I/O Function 31 Monitor Turbine Speed Interface Item Speed Interfacing Entity 24 Drive Turbine8 Turbine Table 14 9 Water Pump External I/O Function 0 Operate OTEC System Interface Item Water Interfacing Entity 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser — 27 — Saturday, November 21, 2009 4 Interfaces Table 14 9 Water Pump External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central — 28 — Saturday, November 21, 2009 4 Interfaces Table 14 9 Water Pump External I/O Function Interface Item Interfacing Entity Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 22 Pump Water Cold Water 26 Condense Working Fluid3 Condenser 22 Pump Water Hot Water 23 Evaporate Working Fluid4 Evaporator 23 Evaporate Working FluidCOOL OCEAN WATER 23 Evaporate Working FluidDEEP COLD OCEAN WATER 23 Evaporate Working FluidWARM OCEAN WATER 23 Evaporate Working FluidWARM OCEAN SURFACE WATER 22 Pump Water Pump Power 36 Monitor Pump Power9.1 Pump Power Sensor 22 Pump Water Net Power 25 Spin Generator6 Generator 22 Pump Water System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer Table 15 9.1 Pump Power Sensor External I/O Function 36 Monitor Pump Power Interface Item Pump Power Interfacing Entity 21 Pump Working Fluids5 Fluid Pump 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump Table 16 COOL OCEAN WATER External I/O Function 0 Operate OTEC System Interface Item Water Interfacing Entity 0 Operate OTEC System1 — 29 — Saturday, November 21, 2009 4 Interfaces Table 16 COOL OCEAN WATER External I/O Function Interface Item Interfacing Entity Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER — 30 — Saturday, November 21, 2009 4 Interfaces Table 16 COOL OCEAN WATER External I/O Function Interface Item Interfacing Entity 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 23 Evaporate Working Fluid Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 23 Evaporate Working Fluid Steam Ammonia 24 Drive Turbine8 Turbine 23 Evaporate Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC 34 Monitor Evaporator Temperature4.1 ThermostatE 23 Evaporate Working Fluid Hot Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 23 Evaporate Working Fluid Liquid Ammonia 26 Condense Working Fluid3 Condenser Table 17 DEEP COLD OCEAN WATER External I/O Function 0 Operate OTEC System Interface Item Water Interfacing Entity 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine — 31 — Saturday, November 21, 2009 4 Interfaces Table 17 DEEP COLD OCEAN WATER External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 23 Evaporate Working Fluid Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 23 Evaporate Working Fluid Steam Ammonia 24 Drive Turbine8 Turbine 23 Evaporate Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC — 32 — Saturday, November 21, 2009 4 Interfaces Table 17 DEEP COLD OCEAN WATER External I/O Function Interface Item Interfacing Entity 34 Monitor Evaporator Temperature4.1 ThermostatE 23 Evaporate Working Fluid Hot Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 23 Evaporate Working Fluid Liquid Ammonia 26 Condense Working Fluid3 Condenser Table 18 WARM OCEAN WATER External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System Water 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser — 33 — Saturday, November 21, 2009 4 Interfaces Table 18 WARM OCEAN WATER External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN SURFACE WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 23 Evaporate Working Fluid Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 23 Evaporate Working Fluid Steam Ammonia 24 Drive Turbine8 Turbine 23 Evaporate Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC 34 Monitor Evaporator Temperature4.1 ThermostatE 23 Evaporate Working Fluid Hot Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 23 Evaporate Working Fluid Liquid Ammonia 26 Condense Working Fluid3 Condenser Table 19 WARM OCEAN SURFACE WATER External I/O Function 0 Operate OTEC System Interface Item Water Interfacing Entity 0 Operate OTEC System1 Central Computer — 34 — Saturday, November 21, 2009 4 Interfaces Table 19 WARM OCEAN SURFACE WATER External I/O Function Interface Item Interfacing Entity 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System6 Generator 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM OCEAN WATER 0 Operate OTEC System Water 0 Operate OTEC System6 Generator 0 Operate OTEC System1 Central Computer 0 Operate OTEC System2 Cold Water Pipe 0 Operate OTEC System3 Condenser 0 Operate OTEC System4 Evaporator 0 Operate OTEC System5 Fluid Pump 0 Operate OTEC System7 Hot Water Pipe 0 Operate OTEC System8 Turbine 0 Operate OTEC System9 Water Pump 0 Operate OTEC SystemCOOL OCEAN WATER 0 Operate OTEC SystemDEEP COLD OCEAN WATER 0 Operate OTEC SystemWARM — 35 — Saturday, November 21, 2009 4 Interfaces Table 19 WARM OCEAN SURFACE WATER External I/O Function Interface Item Interfacing Entity OCEAN WATER 2 Generate Power Data 3 Monitor Health1 Central Computer 2 Generate Power System Controls 1 Control OTEC System1 Central Computer 13 Control System1 Central Computer 14 Stop OTEC System1 Central Computer 23 Evaporate Working Fluid Fluid Pressure 35 Monitor Fluid Pressure5.1 Pressure Sensor 23 Evaporate Working Fluid Steam Ammonia 24 Drive Turbine8 Turbine 23 Evaporate Working Fluid Temperature 33 Monitor Condenser Temperature3.1 ThermostatC 34 Monitor Evaporator Temperature4.1 ThermostatE 23 Evaporate Working Fluid Hot Water 22 Pump Water2 Cold Water Pipe 22 Pump Water7 Hot Water Pipe 22 Pump Water9 Water Pump 23 Evaporate Working Fluid Liquid Ammonia 26 Condense Working Fluid3 Condenser Part II - Interfaces Cold Water input Connecting Systems/Components: 2 Cold Water Pipe 0 OTEC System DEEP COLD OCEAN WATER Cool Water output Connecting Systems/Components: 3 Condenser 0 OTEC System COOL OCEAN WATER Surface water input Connecting Systems/Components: 7 Hot Water Pipe — 36 — Saturday, November 21, 2009 4 Interfaces 0 OTEC System WARM OCEAN SURFACE WATER Warm Water Output Connecting Systems/Components: 4 Evaporator 0 OTEC System WARM OCEAN WATER Part III - Links Part IV - Exchange Characteristics — 37 — Saturday, November 21, 2009 5 Functional Model Part I - Functional List 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 11 Start OTEC System 12 Run OTEC CPU 13 Control System 14 Stop OTEC System 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Part II - Behavioral Model 0 Operate OTEC System Description: Top Level fuction or view of the OTEC System Performed By: 1 Central Computer 2 Cold Water Pipe 3 Condenser 4 Evaporator 5 Fluid Pump 6 Generator 7 Hot Water Pipe 8 Turbine 9 Water Pump COOL OCEAN WATER DEEP COLD OCEAN WATER WARM OCEAN WATER WARM OCEAN SURFACE WATER Based On: — 38 — Saturday, November 21, 2009 5 Functional Model C.1 Electricity Cost C.2 Time to Market C.3 Renewable C.4 Adaptable C.5 Scalable C.6 Environment C.7 Energy Capacity C.8 Availability C.9 Efficiency C.10 Lifetime C.11 Job Creation C.12 O&M Costs C.13 Capital Cost F.1 OTEC Process F.2 Working Fluid F.3 Power F.4 Transmission Voltage F.5 Power Factor F.6 Distribution Voltage F.7 Frequency F.8 Generator Connection F.9 Distribution regulations F.10 Distribution Cable F.11 Transmission Protection F.12 Distance from shore N.1 Command N.2 Communication N.3 Monitoring and Control N.4 System Lifetime N.5 System Availability N.6 Survivability N.7 Construction N.8 Maintenance of Subsystems N.9 MTTR N.10 Sea Safety N.11 Environmental Safety Q.1 Modularity Q.2 Component Lifetime Q.3 Quality Efficiency Q.4 Commercial Components Q.5 Recycled Power Q.6 Supportability Q.7 Human Factors Q.8 Redundancies Q.9 Power Cable Q.10 Used Water — 39 — Saturday, November 21, 2009 5 Functional Model Table 20 0 Operate OTEC System Interfacing Items Interfacing Item Authorization Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 11 Start OTEC System 14 Stop OTEC System Performance Rules Triggers: 0 Operate OTEC System 1 Control OTEC System 12 Run OTEC CPU Power Output From: 0 Operate OTEC System 2 Generate Power 25 Spin Generator Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Startup Power Input To: 0 Operate OTEC System 2 Generate Power — 40 — Saturday, November 21, 2009 5 Functional Model Table 20 0 Operate OTEC System Interfacing Items Interfacing Item Source / Destination 21 Pump Working Fluids Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Water Input To: 0 Operate OTEC System Output From: 0 Operate OTEC System Performanc e Rules Startup Standards Power Regulations Update Authorizatio Deep Cold n Water Hot Surface ... 1 Ref. 2 Control OTEC System 3 Generate Power System Data Controls Cool Water Warm Water Ref. Monitor Health Status Power Date: Saturday, November 21, 2009 Author: Number: Name: (University) Operate OTEC Sys tem 0 University User Figure 3 Operate OTEC System Enhanced FFBD — 41 — Saturday, November 21, 2009 5 Functional Model 1 Ref. 2 Control OTEC System 3 Generate Power Ref. Monitor Health Date: Saturday, November 21, 2009 Author: Number: Name: (University) Operate OTEC System 0 University User Figure 4 Operate OTEC System FFBD Authorization Performanc... Standards Update Deep Cold ... Hot Surfac... Regulations Standards Standards 1 System Controls Control OTEC System 2 Cool Water Power Warm Water Data Generate Power 3 Monitor Health Status Date: Saturday, November 21, 2009 Author: Number: Name: (University) Operate OTEC System 0 University User Figure 5 Operate OTEC System N2 Diagram — 42 — Saturday, November 21, 2009 5 Functional Model Authorization Performance Rules Regulations Standards 1 Update Control OTEC System System Controls 2 Startup Power Hot Surface Water Deep Cold Water Generate Power Warm Water Cool Water Power Data 3 Status Monitor Health Cold Water Pipe Central Condenser Computer COOL OCEAN WATER DEEP COLD OCEAN WATER Evaporator Fluid Pump Generator Hot Water Pipe Turbine WARM OCEAN WATER WARM OCEAN SURFACE WATER Water Pump Date: Saturday, November 21, 2009 Author: Number: Name: (University) Operate OTEC Sys tem — 43 — 0 University User Saturday, November 21, 2009 5 Functional Model Figure 6 Operate OTEC System IDEF0 Diagram 1 Control OTEC System Performed By: 1 Central Computer Based On: N.1 Command N.2 Communication N.3 Monitoring and Control N.11 Environmental Safety Q.7 Human Factors Q.8 Redundancies S.11 Emergency Shutoff S.13 Computer S.14 Processing S.15 Error Monitoring S.16 Health Monitoring S.17 Corrective Action Table 21 1 Control OTEC System Interfacing Items Interfacing Item Authorization Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 11 Start OTEC System 14 Stop OTEC System Performance Rules Triggers: 0 Operate OTEC System 1 Control OTEC System 12 Run OTEC CPU Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure — 44 — Saturday, November 21, 2009 5 Functional Model Table 21 1 Control OTEC System Interfacing Items Interfacing Item Source / Destination 36 Monitor Pump Power System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System Update Input To: 1 Control OTEC System 12 Run OTEC CPU Authorizatio n Update 11 Ref. Performanc Standards e Rules 12 Start OTEC System 13 Run OTEC CPU Start 14 2 Stop OTEC System Control System Generate Power System Controls Controls Date: Saturday, November 21, 2009 Author: Number: Name: (University) Control OTEC System 1 University User Figure 7 Control OTEC System Enhanced FFBD 11 Ref. 12 Start OTEC System Run OTEC CPU 13 14 2 Stop OTEC System Control System Generate Power Date: Saturday, November 21, 2009 Author: Number: Name: (University) Control OTEC System 1 Figure 8 Control OTEC System FFBD — 45 — University User Saturday, November 21, 2009 5 Functional Model Performance Rules Update Authorization Standards Authorization 11 Start OTEC System Start 12 Controls Run OTEC CPU Controls 13 System Controls Control System 14 Stop OTEC System System Controls Date: Saturday, November 21, 2009 Author: Number: Name: (University) Control OTEC System 1 University User Figure 9 Control OTEC System N2 Diagram — 46 — Saturday, November 21, 2009 5 Functional Model Performance Rules Standards Authorization 11 Start OTEC System Start 12 Update Run OTEC CPU Controls 13 System Controls Control System 14 Stop OTEC System Central Computer Date: Saturday, November 21, 2009 Author: Number: Name: (University) Control OTEC System 1 Figure 10 Control OTEC System IDEF0 Diagram 2 Generate Power Performed By: 2 Cold Water Pipe 3 Condenser 4 Evaporator 5 Fluid Pump 6 Generator 7 Hot Water Pipe 8 Turbine 9 Water Pump COOL OCEAN WATER DEEP COLD OCEAN WATER — 47 — University User Saturday, November 21, 2009 5 Functional Model WARM OCEAN WATER WARM OCEAN SURFACE WATER Based On: F.1 OTEC Process F.2 Working Fluid F.3 Power F.4 Transmission Voltage F.5 Power Factor F.6 Distribution Voltage F.7 Frequency F.8 Generator Connection F.9 Distribution regulations F.10 Distribution Cable F.11 Transmission Protection F.12 Distance from shore N.4 System Lifetime N.6 Survivability N.7 Construction Q.2 Component Lifetime Q.3 Quality Efficiency Q.4 Commercial Components Q.5 Recycled Power Q.6 Supportability Q.9 Power Cable Q.10 Used Water S.1 Pumps S.2 Heat Exchangers S.3 Turbine S.4 Generator S.5 Component Selection S.6 Voltage Regulators Table 22 2 Generate Power Interfacing Items Interfacing Item Cool Water Source / Destination Output From: 2 Generate Power 26 Condense Working Fluid Data Input To: 3 Monitor Health Output From: 2 Generate Power Deep Cold Water Input To: 2 Generate Power 22 Pump Water Hot Surface Water Input To: — 48 — Saturday, November 21, 2009 5 Functional Model Table 22 2 Generate Power Interfacing Items Interfacing Item Source / Destination 2 Generate Power 22 Pump Water Power Output From: 0 Operate OTEC System 2 Generate Power 25 Spin Generator Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Startup Power Input To: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System — 49 — Saturday, November 21, 2009 5 Functional Model Table 22 2 Generate Power Interfacing Items Interfacing Item Source / Destination 13 Control System 14 Stop OTEC System Warm Water Output From: 2 Generate Power 23 Evaporate Working Fluid Regulations Startup Power Liquid Ammonia 1 System Controls Deep Cold Net Power Water 21 Control OTEC System 22 Pump Working Fluids Pump Power Hot Surface ... Standards 23 Pump Water Fluid Hot Water Pressure 24 Evaporate Working Fluid Temperatur Cold Water e 25 Drive Turbine Steam Mechanical Ammonia Energy Warm Water 26 Spin Generator Ammonia Power Steam 3 Condense Working Fluid Output Power Monitor Health Cool Water Speed Date: Saturday, November 21, 2009 Author: Number: Name: (University) Generate Power 2 University User Figure 11 Generate Power Enhanced FFBD 1 21 Control OTEC System Pump Working Fluids 22 23 Pump Water 24 Evaporate Working Fluid 25 Drive Turbine 26 Condense Working Fluid Spin Generator Monitor Health Date: Saturday, November 21, 2009 Author: Number: Name: (University) Generate Power Figure 12 Generate Power FFBD — 50 — 3 2 University User Saturday, November 21, 2009 5 Functional Model Regulations Startup Power System Con... Deep Cold ... Hot Surfac... Regulations System Con... Regulations Regulations Standards Regulations Regulations Standards 21 Fluid Pressure Pump Power Pump Working Fluids 22 Hot Water Pump Water Cold Water Pump Power 23 Fluid Pressure Temperature Warm Water Steam Ammonia Evaporate Working Fluid 24 Mechanical Energy Drive Turbine Ammonia Steam Speed 25 Net Power Net Power Output Power Power Spin Generator 26 Liquid Ammonia Liquid Ammonia Condense Working Fluid Cool Water Temperature Date: Saturday, November 21, 2009 Author: Number: Name: (University) Generate Power 2 Figure 13 Generate Power N2 Diagram — 51 — University User Saturday, November 21, 2009 5 Functional Model Standards Regulations Startup Power System Controls 21 Fluid Pressure Pump Working Fluids Data Pump Power 22 Deep Cold Water Hot Surface Water Pump Power Pump Water Cold Water Hot Water 23 Evaporate Working Fluid Temperature Fluid Pressure Warm Water Steam Ammonia 24 Speed Drive Turbine Ammonia Steam Mechanical Energy 25 Spin Generator Power Output Power Net Power 26 Temperature Condense Working Fluid Fluid Pump Cold Water Pipe Hot Water Pipe Water Pump COOL OCE... DEEP COLD OCE... Evaporator WARM OCE... WARM OCEAN SURFA... Turbine Generator Performed By: 1 Central Computer Based On: N.3 Monitoring and Control — 52 — Condenser Date: Saturday, November 21, 2009 Author: Number: Name: (University) Generate Power Figure 14 Generate Power IDEF0 Diagram 3 Monitor Health Cool Water Liquid Ammonia 2 University User Saturday, November 21, 2009 5 Functional Model N.8 Maintenance of Subsystems N.9 MTTR N.11 Environmental Safety Q.3 Quality Efficiency Q.4 Commercial Components Q.6 Supportability S.7 Tachometer rating S.8 Tachometer status S.9 Thermocouple rating S.10 Voltage Meters S.11 Emergency Shutoff S.12 Contol subsystem Table 23 3 Monitor Health Interfacing Items Interfacing Item Data Source / Destination Input To: 3 Monitor Health Output From: 2 Generate Power Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power — 53 — Saturday, November 21, 2009 5 Functional Model Output Power 2 Generate Power Fluid Standards Pressure 32 Temperatur e 35 Monitor Generator Power 34 Monitor Evaporator Temperature Monitor Fluid Pressure Pump Power Speed 36 31 Monitor Pump Power 33 Monitor Condenser Temperature Monitor Turbine Speed Ref. Status Date: Saturday, November 21, 2009 Author: Number: Name: 3 University User (University) Monitor Health Figure 15 Monitor Health Enhanced FFBD 2 Generate Power 32 Monitor Generator Power 35 34 Monitor Fluid Pressure 36 Monitor Evaporator Temperature Monitor Pump Power 31 33 Ref. Date: Saturday, November 21, 2009 Author: Number: Name: Figure 16 Monitor Health FFBD — 54 — Monitor Condenser Temperature Monitor Turbine Speed 3 University User (University) Monitor Health Saturday, November 21, 2009 5 Functional Model Output Power Standards Fluid Pressure Standards Standards Temperature Pump Power Standards Speed Standards Standards Temperature 32 Monitor Generator Power Status 35 Monitor Fluid Pressure Status 34 Monitor Evaporator Temperature Status 36 Monitor Pump Power Status 31 Monitor Turbine Speed Status 33 Monitor Condenser Temperature Date: Saturday, November 21, 2009 Author: Number: Name: 3 Figure 17 Monitor Health N2 Diagram — 55 — Status University User (University) Monitor Health Saturday, November 21, 2009 5 Functional Model Standards 32 Output Power Data Monitor Generator Power Status 35 Fluid Pressure Monitor Fluid Pressure 34 Temperature Monitor Evaporator Temperature 36 Pump Power Monitor Pump Power 31 Speed Monitor Turbine Speed 33 Temperature Power Sensor Pressure Sensor ThermostatE Pump Power Sensor Monitor Condenser Temperature ThermostatC Tachometer Central Computer Date: Saturday, November 21, 2009 Author: Number: Name: 3 Figure 18 Monitor Health IDEF0 Diagram 11 Start OTEC System Performed By: 1 Central Computer Table 24 11 Start OTEC System Interfacing Items Interfacing Item Authorization Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 11 Start OTEC System 14 Stop OTEC System — 56 — University User (University) Monitor Health Saturday, November 21, 2009 5 Functional Model Table 24 11 Start OTEC System Interfacing Items Interfacing Item Start Source / Destination Input To: 13 Control System Output From: 11 Start OTEC System 12 Run OTEC CPU Performed By: 1 Central Computer Table 25 12 Run OTEC CPU Interfacing Items Interfacing Item Controls Source / Destination Input To: 13 Control System 14 Stop OTEC System Output From: 12 Run OTEC CPU Performance Rules Triggers: 0 Operate OTEC System 1 Control OTEC System 12 Run OTEC CPU Update Input To: 1 Control OTEC System 12 Run OTEC CPU 13 Control System Performed By: 1 Central Computer Table 26 13 Control System Interfacing Items Interfacing Item Controls Source / Destination Input To: 13 Control System 14 Stop OTEC System Output From: 12 Run OTEC CPU Standards Triggers: 0 Operate OTEC System — 57 — Saturday, November 21, 2009 5 Functional Model Table 26 13 Control System Interfacing Items Interfacing Item Source / Destination 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Start Input To: 13 Control System Output From: 11 Start OTEC System System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System 14 Stop OTEC System Performed By: 1 Central Computer Table 27 14 Stop OTEC System Interfacing Items Interfacing Item Authorization Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 11 Start OTEC System 14 Stop OTEC System Controls Input To: 13 Control System — 58 — Saturday, November 21, 2009 5 Functional Model Table 27 14 Stop OTEC System Interfacing Items Interfacing Item Source / Destination 14 Stop OTEC System Output From: 12 Run OTEC CPU System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System 21 Pump Working Fluids Performed By: 5 Fluid Pump Table 28 21 Pump Working Fluids Interfacing Items Interfacing Item Fluid Pressure Source / Destination Input To: 35 Monitor Fluid Pressure Output From: 21 Pump Working Fluids 23 Evaporate Working Fluid Liquid Ammonia Input To: 21 Pump Working Fluids 23 Evaporate Working Fluid Output From: 26 Condense Working Fluid Net Power Input To: 21 Pump Working Fluids 22 Pump Water Output From: 25 Spin Generator Pump Power Input To: 36 Monitor Pump Power Output From: 21 Pump Working Fluids — 59 — Saturday, November 21, 2009 5 Functional Model Table 28 21 Pump Working Fluids Interfacing Items Interfacing Item Source / Destination 22 Pump Water Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Startup Power Input To: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System 22 Pump Water Performed By: 2 Cold Water Pipe 7 Hot Water Pipe 9 Water Pump Table 29 22 Pump Water Interfacing Items Interfacing Item Cold Water Source / Destination Input To: 26 Condense Working Fluid Output From: 22 Pump Water Deep Cold Water Input To: 2 Generate Power 22 Pump Water — 60 — Saturday, November 21, 2009 5 Functional Model Table 29 22 Pump Water Interfacing Items Interfacing Item Hot Surface Water Source / Destination Input To: 2 Generate Power 22 Pump Water Hot Water Input To: 23 Evaporate Working Fluid Output From: 22 Pump Water Net Power Input To: 21 Pump Working Fluids 22 Pump Water Output From: 25 Spin Generator Pump Power Input To: 36 Monitor Pump Power Output From: 21 Pump Working Fluids 22 Pump Water Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System 23 Evaporate Working Fluid Performed By: 4 Evaporator — 61 — Saturday, November 21, 2009 5 Functional Model COOL OCEAN WATER DEEP COLD OCEAN WATER WARM OCEAN WATER WARM OCEAN SURFACE WATER Table 30 23 Evaporate Working Fluid Interfacing Items Interfacing Item Fluid Pressure Source / Destination Input To: 35 Monitor Fluid Pressure Output From: 21 Pump Working Fluids 23 Evaporate Working Fluid Hot Water Input To: 23 Evaporate Working Fluid Output From: 22 Pump Water Liquid Ammonia Input To: 21 Pump Working Fluids 23 Evaporate Working Fluid Output From: 26 Condense Working Fluid Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Steam Ammonia Input To: 24 Drive Turbine Output From: 23 Evaporate Working Fluid Temperature Input To: 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature Output From: 23 Evaporate Working Fluid 26 Condense Working Fluid Warm Water Output From: — 62 — Saturday, November 21, 2009 5 Functional Model Table 30 23 Evaporate Working Fluid Interfacing Items Interfacing Item Source / Destination 2 Generate Power 23 Evaporate Working Fluid 24 Drive Turbine Performed By: 8 Turbine Table 31 24 Drive Turbine Interfacing Items Interfacing Item Ammonia Steam Source / Destination Input To: 26 Condense Working Fluid Output From: 24 Drive Turbine Mechanical Energy Input To: 25 Spin Generator Output From: 24 Drive Turbine Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Speed Input To: 31 Monitor Turbine Speed Output From: 24 Drive Turbine Steam Ammonia Input To: 24 Drive Turbine Output From: 23 Evaporate Working Fluid 25 Spin Generator Performed By: — 63 — Saturday, November 21, 2009 5 Functional Model 6 Generator Table 32 25 Spin Generator Interfacing Items Interfacing Item Mechanical Energy Source / Destination Input To: 25 Spin Generator Output From: 24 Drive Turbine Net Power Input To: 21 Pump Working Fluids 22 Pump Water Output From: 25 Spin Generator Output Power Input To: 32 Monitor Generator Power Output From: 25 Spin Generator Power Output From: 0 Operate OTEC System 2 Generate Power 25 Spin Generator Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature — 64 — Saturday, November 21, 2009 5 Functional Model Table 32 25 Spin Generator Interfacing Items Interfacing Item Source / Destination 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power 26 Condense Working Fluid Performed By: 3 Condenser Table 33 26 Condense Working Fluid Interfacing Items Interfacing Item Ammonia Steam Source / Destination Input To: 26 Condense Working Fluid Output From: 24 Drive Turbine Cold Water Input To: 26 Condense Working Fluid Output From: 22 Pump Water Cool Water Output From: 2 Generate Power 26 Condense Working Fluid Liquid Ammonia Input To: 21 Pump Working Fluids 23 Evaporate Working Fluid Output From: 26 Condense Working Fluid Regulations Triggers: 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Standards Triggers: 0 Operate OTEC System 1 Control OTEC System — 65 — Saturday, November 21, 2009 5 Functional Model Table 33 26 Condense Working Fluid Interfacing Items Interfacing Item Source / Destination 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Temperature Input To: 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature Output From: 23 Evaporate Working Fluid 26 Condense Working Fluid 31 Monitor Turbine Speed Performed By: 8.1 Tachometer Table 34 31 Monitor Turbine Speed Interfacing Items Interfacing Item Speed Source / Destination Input To: 31 Monitor Turbine Speed Output From: 24 Drive Turbine Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power — 66 — Saturday, November 21, 2009 5 Functional Model Table 34 31 Monitor Turbine Speed Interfacing Items Interfacing Item Source / Destination 33 34 35 36 Status Monitor Condenser Temperature Monitor Evaporator Temperature Monitor Fluid Pressure Monitor Pump Power Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power 32 Monitor Generator Power Performed By: 6.1 Power Sensor Table 35 32 Monitor Generator Power Interfacing Items Interfacing Item Output Power Source / Destination Input To: 32 Monitor Generator Power Output From: 25 Spin Generator Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power — 67 — Saturday, November 21, 2009 5 Functional Model Table 35 32 Monitor Generator Power Interfacing Items Interfacing Item Status Source / Destination Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power 33 Monitor Condenser Temperature Performed By: 3.1 ThermostatC Table 36 33 Monitor Condenser Temperature Interfacing Items Interfacing Item Standards Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power — 68 — Saturday, November 21, 2009 5 Functional Model Table 36 33 Monitor Condenser Temperature Interfacing Items Interfacing Item Temperature Source / Destination Input To: 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature Output From: 23 Evaporate Working Fluid 26 Condense Working Fluid 34 Monitor Evaporator Temperature Performed By: 4.1 ThermostatE Table 37 34 Monitor Evaporator Temperature Interfacing Items Interfacing Item Standards Source / Destination Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Temperature Input To: 33 Monitor Condenser Temperature — 69 — Saturday, November 21, 2009 5 Functional Model Table 37 34 Monitor Evaporator Temperature Interfacing Items Interfacing Item Source / Destination 34 Monitor Evaporator Temperature Output From: 23 Evaporate Working Fluid 26 Condense Working Fluid 35 Monitor Fluid Pressure Performed By: 5.1 Pressure Sensor Table 38 35 Monitor Fluid Pressure Interfacing Items Interfacing Item Fluid Pressure Source / Destination Input To: 35 Monitor Fluid Pressure Output From: 21 Pump Working Fluids 23 Evaporate Working Fluid Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure — 70 — Saturday, November 21, 2009 5 Functional Model Table 38 35 Monitor Fluid Pressure Interfacing Items Interfacing Item Source / Destination 36 Monitor Pump Power 36 Monitor Pump Power Performed By: 9.1 Pump Power Sensor Table 39 36 Monitor Pump Power Interfacing Items Interfacing Item Pump Power Source / Destination Input To: 36 Monitor Pump Power Output From: 21 Pump Working Fluids 22 Pump Water Standards Triggers: 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Status Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Part III - Item Dictionary — 71 — Saturday, November 21, 2009 5 Functional Model Ammonia Steam Input To: 26 Condense Working Fluid Output From: 24 Drive Turbine Authorization Triggers Function(s): 0 Operate OTEC System 1 Control OTEC System 11 Start OTEC System 14 Stop OTEC System Cold Water Decomposes: Water Input To: 26 Condense Working Fluid Output From: 22 Pump Water Controls Input To: 13 Control System 14 Stop OTEC System Output From: 12 Run OTEC CPU Cool Water Decomposes: Water Output From: 2 Generate Power 26 Condense Working Fluid Data Decomposed into Lower-Level Item(s): Fluid Pressure Output Power Pump Power Speed Temperature — 72 — Saturday, November 21, 2009 5 Functional Model Input To: 3 Monitor Health Output From: 2 Generate Power Deep Cold Water Decomposes: Water Input To: 2 Generate Power 22 Pump Water Fluid Pressure Decomposes: Data Input To: 35 Monitor Fluid Pressure Output From: 21 Pump Working Fluids 23 Evaporate Working Fluid Hot Surface Water Decomposes: Water Input To: 2 Generate Power 22 Pump Water Hot Water Decomposes: Water Input To: 23 Evaporate Working Fluid Output From: 22 Pump Water Liquid Ammonia Input To: 21 Pump Working Fluids 23 Evaporate Working Fluid Output From: 26 Condense Working Fluid — 73 — Saturday, November 21, 2009 5 Functional Model Mechanical Energy Input To: 25 Spin Generator Output From: 24 Drive Turbine Net Power Input To: 21 Pump Working Fluids 22 Pump Water Output From: 25 Spin Generator Output Power Decomposes: Data Input To: 32 Monitor Generator Power Output From: 25 Spin Generator Performance Rules Triggers Function(s): 0 Operate OTEC System 1 Control OTEC System 12 Run OTEC CPU Power Output From: 0 Operate OTEC System 2 Generate Power 25 Spin Generator Pump Power Decomposes: Data Input To: 36 Monitor Pump Power Output From: 21 Pump Working Fluids 22 Pump Water — 74 — Saturday, November 21, 2009 5 Functional Model Regulations Triggers Function(s): 0 Operate OTEC System 2 Generate Power 21 Pump Working Fluids 22 Pump Water 23 Evaporate Working Fluid 24 Drive Turbine 25 Spin Generator 26 Condense Working Fluid Speed Decomposes: Data Input To: 31 Monitor Turbine Speed Output From: 24 Drive Turbine Standards Triggers Function(s): 0 Operate OTEC System 1 Control OTEC System 2 Generate Power 3 Monitor Health 13 Control System 25 Spin Generator 26 Condense Working Fluid 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Start Input To: 13 Control System Output From: 11 Start OTEC System Startup Power Input To: 0 Operate OTEC System — 75 — Saturday, November 21, 2009 5 Functional Model 2 Generate Power 21 Pump Working Fluids Status Decomposed into Lower-Level Item(s): Update Output From: 0 Operate OTEC System 3 Monitor Health 31 Monitor Turbine Speed 32 Monitor Generator Power 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature 35 Monitor Fluid Pressure 36 Monitor Pump Power Steam Ammonia Input To: 24 Drive Turbine Output From: 23 Evaporate Working Fluid System Controls Input To: 2 Generate Power 21 Pump Working Fluids 22 Pump Water Output From: 1 Control OTEC System 13 Control System 14 Stop OTEC System Temperature Decomposes: Data Input To: 33 Monitor Condenser Temperature 34 Monitor Evaporator Temperature Output From: 23 Evaporate Working Fluid 26 Condense Working Fluid — 76 — Saturday, November 21, 2009 5 Functional Model Update Decomposes: Status Input To: 1 Control OTEC System 12 Run OTEC CPU Warm Water Decomposes: Water Output From: 2 Generate Power 23 Evaporate Working Fluid Water Decomposed into Lower-Level Item(s): Cold Water Cool Water Deep Cold Water Hot Surface Water Hot Water Warm Water Input To: 0 Operate OTEC System Output From: 0 Operate OTEC System — 77 — Saturday, November 21, 2009 6 Risks R.1 Aggressive Schedule Risk Type: Schedule Impact: Medium Status: Active Mitigation Plan: Proactively track activities. Reconcile budgeted cost of work performed against actual cost of work performed on weekly basis. Keep open communication with customer and partners to ensure all parties are aware of any schedule changes or delays. Master Scheduling Planner to update and publish overall schedule to the team to be posted on R.2 Technology Incompatibilities Risk Type: Technical Impact: Medium Status: Managing Mitigation Plan: Schedule monthly Interface IPT working group with partners and suppliers to understand technology interfacing requirements and interface protocols. Ensure Interface Control Documents(ICDs) are submitted, reviewed, and agreed upon prior to design finalization. R.3 Requirements Creep Risk Type: Technical Impact: Low Status: Managing Mitigation Plan: Work to develop firm and agreed upon stated and derived requirements with customer. Establish Engineering Change review board and engineering change proposals as a vehicle for documenting upscope activities. Monitor activities and only work to customer approved engineering changes. R.4 Meeting Requirements and Expectations Risk Type: Technical Status: Active Mitigation Plan: — 78 — Saturday, November 21, 2009 6 Risks Create a Requirements Integrated Project Team (IPT) with customer. Participants to include stakeholders including: partners, customer, and internal team. IPT will serve to discuss and communicate all requirements changes with team. Project status will be communicated with all parties so that all stakeholders will have an understanding of overall progress of the project. R.5 Training of Personnel Risk Type: Technical Impact: Low Status: Plan Mitigation Plan: Ensure that Training and Technology manuals are budgeted and reviewed againt logisitics team for accurracy. Provide training material to the customer for final approval for comments prior to final delivery. R.6 Stability of Utility Provider Risk Type: Cost Status: Active Mitigation Plan: Work with Utility provider to ensure that proper infastructure is in place prior to Power Purchase Contract is finalized and signed. Provide detailed requirements to local utillity provider early in development phase such that proper eqiupment may be located or installed or ordered for interface with OTEC system. R.7 Environmental Impacts Risk Type: Technical Status: Active Mitigation Plan: Work with local environmental groups to understand concerns and particular ecosystems in area of platform. Establish working dialog with community groups to understand issues and factor these needs into development of the system. R.8 Suitable location of platform (Best and worst case temperature differential, distance from shore) Risk Type: Technical Impact: Low Status: Active — 79 — Saturday, November 21, 2009 6 Risks Mitigation Plan: Work with NOAA to fully understand the ocean bathometry and average monthly temperature at depth. By understanding environmental factors, the most feasible location can be selected. R.9 Selection of subcontractors Risk Type: Technical Status: Managing Mitigation Plan: Leverage subcontractor research performed by the Lockheed Martin customer and select subcontractors with a history exemplary performance and ethics. R.10 Selection of major components Risk Type: Technical Impact: Low Status: Managing Mitigation Plan: Leverage expertise of partners and involve stakeholders R.11 Suitable onshore manufacturing facility Risk Type: Schedule Status: Managing Mitigation Plan: Work with Nigerian Government to select an approprate fanufactoring facility. Work with subcontracts team to identify commercially available ships, dry docks, tugs, and similar marine construction crafts. R.12 System security Risk Type: Technical Status: Active Mitigation Plan: Piracy has been an issue for some Oil Refineries in the Niger Delta. The OTEC system will best practices to insure crew members are safe during their time on the platform. R.13 Underwater marine cable Risk Type: Technical — 80 — Saturday, November 21, 2009 6 Risks Status: Managing Mitigation Plan: Size marine cable to handle 15% higher voltage rating that the expected peak power distribution. Work with local environmental groups to understand the particular environment where the cable is to be placed to ensure minimal impact on the ecosystem. R.14 Working Fluid Leaks Risk Type: Technical Status: Plan Mitigation Plan: Develop a strict maintenance schedule and procedure for the working fluid subsystem. Crew are to follow the documented procedure and OSHA regulations to ensure ammonia spills are handled as mandated in regulations. R.15 OTEC Platform Costs Risk Type: Cost Impact: High Status: Managing Mitigation Plan: Perform studies to determine the correct location for the OTEC platform, sizing of heat exchangers, pumps, cold water pipe, and other major subsystem components R.16 Unfamiliar Design Elements Risk Type: Technical Impact: Low Status: Managing Mitigation Plan: Leverage expertise of partners and involve stakeholders — 81 —