Install torch on roof membrane

advertisement
10810 version 3
Page 1 of 4
Install torch on roof membrane
Level
4
Credits
35
Purpose
People credited with this unit standard are able to: confirm materials and
availability of equipment for installation of torch on roof membrane; complete
preparations for the installation of the torch on roof membrane; carry out
installation of torch on roof membrane; complete and finish torch on roof
membrane; and maintain a safe working environment.
Subfield
Plumbing, Gasfitting and Drainlaying
Domain
Roofing
Status
Registered
Status date
23 January 2009
Date version published
23 January 2009
Planned review date
31 December 2013
Entry information
Open.
Accreditation
Evaluation of documentation and visit by NZQA and
industry.
Standard setting body (SSB)
The Skills Organisation
Accreditation and Moderation Action Plan (AMAP) reference
0227
This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do.
Special notes
1
Legislation relevant to this unit standard includes but is not limited to – Health and
Safety in Employment Act 1992, Building Act 2004.
2
Definitions
Company requirements – include the policies, procedures, and methodologies of the
company. They include requirements documented in company and site health and
safety plans, quality assurance documents, and contract work programmes.
Site procedures – refer to the procedures which are required to be observed for safe
work practices at a particular site.
Job specifications – refer to the documented information found in construction
drawings, project specification documents, legislation, regulations and codes.
 New Zealand Qualifications Authority 2016
10810 version 3
Page 2 of 4
Manufacturer recommendations – refer to product information and product data
sheets provided by the manufacturer of any given product.
Health and safety in employment guidelines – refer to the Guidelines for the
Provision of Facilities and General Safety in the Construction Industry, 1995. These
guidelines apply to all construction workplaces. They contain relevant sections of the
Health and Safety in Employment Act 1992 and regulations, generally accepted good
practice, and references to further information. They are available from the
Occupational Health and Safety Service of the Department of Labour
http://www.osh.govt.nz/.
3
This unit standard applies to both new roof and re-roofing installations on residential
and commercial sites.
Elements and performance criteria
Element 1
Confirm materials and availability of equipment for installation of torch on roof membrane.
Performance criteria
1.1
Job is assessed and a plan of work is drawn up in accordance with company
requirements.
1.2
Materials confirmed for the job are consistent with the job specifications and
manufacturer recommendations.
Range
1.3
includes but is not limited to – membrane, cladding, flashings,
sealants, tapes, cleaners, fillers.
Equipment availability is confirmed in accordance with the job specifications.
Range
includes but is not limited to – fire extinguisher, scaffolding,
ladders, tools, brushes, belt sander, airless spray units, propane
cylinder and torch, angle grinder, heat gun, saws, router, pop
riveter, rollers.
Element 2
Complete preparations for installation of torch on roof membrane.
Performance criteria
2.1
An on-site dangerous goods store is established, where required, and
notification, people, and goods controls are established in accordance with
health and safety in employment guidelines.
2.2
Fire extinguisher is located on site and workers are notified of its location and
extinguisher type and capabilities in accordance with site procedures.
 New Zealand Qualifications Authority 2016
10810 version 3
Page 3 of 4
2.3
Area is prepared in accordance with company requirements.
Range
2.4
area cleaned with blower or vacuum, moisture content of substrate
within accepted parameters.
Any defects in substrate are identified and rectified in accordance with
manufacturer recommendations.
Element 3
Carry out installation of torch on roof membrane.
Performance criteria
3.1
Installation of membrane is completed in accordance with manufacturer
specified sequence.
Range
3.2
primer where required, grid layout set, corner soakers applied,
sheets positioned on grid.
Material is rolled back in sequence in accordance with manufacturer
recommendations.
Element 4
Complete and finish torch on roof membrane.
Performance criteria
4.1
Substrate joint tape is applied, where necessary, in accordance with
manufacturer recommendations.
4.2
Material is laid and finished and applied over flashings to manufacturer
recommendations.
4.3
Expansion joints are prepared to manufacturer recommendations.
Element 5
Maintain a safe working environment.
Performance criteria
5.1
Work practices are carried out without injury to people or damage to equipment,
building, or plant in accordance with legislation, regulations, codes, health and
safety in employment guidelines, and company requirements.
 New Zealand Qualifications Authority 2016
10810 version 3
Page 4 of 4
5.2
Personal protective equipment for the task at hand is selected and worn in
accordance with manufacturer recommendations.
Range
includes but is not limited to – hard hat, sunblock, ear muffs, safety
glasses, gloves, knee pads, high-visibility clothing, safety harness.
5.3
Work area is cordoned off and safety notices and notification of work signs are
distributed and erected in accordance with site procedures.
5.4
Working area is kept clear of debris and unnecessary equipment in accordance
with company requirements.
5.5
Availability of site-specific safety plan is confirmed.
Range
safety plan may include but is not limited to – hazard identification,
working at height, securing loose material, material safety data.
Please note
Providers must be accredited by NZQA, or an inter-institutional body with delegated
authority for quality assurance, before they can report credits from assessment against
unit standards or deliver courses of study leading to that assessment.
Industry Training Organisations must be accredited by NZQA before they can register
credits from assessment against unit standards.
Accredited providers and Industry Training Organisations assessing against unit standards
must engage with the moderation system that applies to those standards.
Accreditation requirements and an outline of the moderation system that applies to this
standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The
AMAP also includes useful information about special requirements for organisations
wishing to develop education and training programmes, such as minimum qualifications for
tutors and assessors, and special resource requirements.
Comments on this unit standard
Please contact The Skills Organisation info@skills.org.nz if you wish to suggest changes
to the content of this unit standard.
 New Zealand Qualifications Authority 2016