NZQA registered unit standard 17905 version 4 Page 1 of 4 Title Operate coal handling equipment in a thermal electricity generation power station Level 3 Credits 6 Purpose People credited with this unit standard are able to: demonstrate knowledge of coal handling equipment and controls; operate and monitor coal handling equipment in a thermal electricity generation power station; and identify and respond to deviations in the normal operation of coal handling equipment. Classification Electricity Supply > Electricity Supply - Thermal Operations and Control Available grade Achieved Explanatory notes 1 This unit standard is intended for, but not restricted to, workplace assessment. The range statements across the unit standard can be applied according to industry specific equipment, procedures and processes. 2 Safety of personnel and plant must be a priority throughout the assessment. If the safety requirements are not met the assessment must stop. 3 Performance and work practices in relation to the outcomes and evidence requirements must comply with all current legislation, especially the Electricity Act 1992, and any regulations and codes of practice recognised under that statute; the Health and Safety in Employment Act 1992; and the Resource Management Act 1991. Electricity supply industry codes of practice and documented industry procedures include the current version of the Safety Manual – Electricity Industry (SM-EI) Wellington: Electricity Engineers’ Association. A full list of current legislation and industry codes is available from the Electricity Supply Industry Training Organisation, PO Box 1245, Hamilton 3240. 4 The phrase in accordance with industry requirements is implicit in all outcomes and evidence requirements in this unit standard. 5 Industry requirements include all asset owner requirements; manufacturers’ specifications; and enterprise requirements which cover the documented workplace policies, procedures, specifications, business, and quality management requirements relevant to the workplace in which assessment is carried out. 6 Coal handling equipment includes overland system, stock-out system, bunkering system, reclaiming system. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17905 version 4 Page 2 of 4 Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of coal handling equipment and controls. Evidence requirements 1.1 Coal handling equipment, location, power supplies, and operations are described. Range 1.2 includes but is not limited to – conveyors, crushers, screens, feeders, magnetic separators, flap gates, sampling systems, belt weighs, bins, chutes, hoppers, bunkers. Operating parameters are identified. Range includes but is not limited to – coal condition, equipment condition, conveyor loading ratings. Outcome 2 Operate and monitor coal handling equipment in a thermal electricity generation power station. Evidence requirements 2.1 Current status of equipment is identified. 2.2 Operations are carried out. Range 2.3 includes but is not limited to – equipment trip resets, monitor equipment, cleaning, manual bunker filling. Operating decisions are determined. Range includes but is not limited to – plant availability and service condition, resource consent and loading limits, impact on operations, options. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17905 version 4 Page 3 of 4 Outcome 3 Identify and respond to deviations in the normal operation of coal handling equipment. Evidence requirements 3.1 Deviations from normal operating conditions are identified, reported and acted upon. includes but is not limited to – blockages, ripped or damaged conveyor belts, festooning, hot coal, excessively dusty coal, wet coal, conditions requiring emergency shutdown, conveyor anti runback device failure, equipment maloperation, trips. Range 3.2 Plant safety, fire and emergency procedures are followed. includes but is not limited to – thermal detectors, smoke detectors, fire-wire, oil spills, manual break-glass switches, fire hydrant boxes, fire detection zoning, sprinklers, hose reels, hydrant fire pumps, booster pumps. Range Planned review date 31 December 2015 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 28 November 2000 N/A Revision 2 11 February 2004 N/A Rollover and Revision 3 25 June 2007 N/A Review 4 9 December 2010 N/A Accreditation and Moderation Action Plan (AMAP) reference 0120 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016 NZQA registered unit standard 17905 version 4 Page 4 of 4 Consent requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the Electricity Supply Industry Training Organisation info@esito.org.nz if you wish to suggest changes to the content of this unit standard. Electricity Supply Industry Training Organisation SSB Code 101813 New Zealand Qualifications Authority 2016