10986 version 5 Page 1 of 4 Use flow-stopping bags in a gas distribution network Level 4 Credits 10 Purpose People credited with this unit standard are able to: locate and identify procedures, documentation, and equipment for using flow-stopping bags; prepare for flow stopping and use flow-stopping bags; reinstate site; and complete reporting and documentation. Subfield Gas Industry Domain Gas Network Construction Status Registered Status date 21 May 2010 Date version published 21 May 2010 Planned review date 31 December 2015 Entry information Open. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) NZ Motor Industry Training Organisation (Incorporated) (MITO) Accreditation and Moderation Action Plan (AMAP) reference 0114 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 This unit standard is intended for, but is not limited to, workplace assessment. The range statements relate to enterprise specific equipment, procedures, and processes. 2 The current version of the following documents must be complied with: Health and Safety in Employment Act 1992; Resource Management Act 1991; Approved Code of Practice for Safety in Excavation and Shafts for Foundations, Occupational Safety and Health Service, Dept of Labour, 1995, available at http://www.osh.dol.govt.nz/order/catalogue/135.shtml; NZS 5258:2003 Gas distribution networks available at http://www.standards.co.nz/. New Zealand Qualifications Authority 2016 10986 version 5 Page 2 of 4 3 All work practices must comply with regulations and codes of practice pertaining to the gas industry. A full list of applicable regulations and codes is available from the NZ Motor Industry Training Organisation (Incorporated) (MITO). 4 Definition Company procedures means the documented methods for performing work activities and include health and safety, environmental, and quality management requirements. They may refer to manuals, codes of practice, or policy statements. Elements and performance criteria Element 1 Locate and identify procedures, documentation and equipment for using flow-stopping bags. Performance criteria 1.1 Company procedures for using flow-stopping bags are located and interpreted in relation to specified job requirements. 1.2 Job instructions are confirmed in accordance with company procedures. Range instructions include – site location, utility plans and/or mark-outs, consents, easements. 1.3 Potential environmental and safety hazards are identified in accordance with company procedures. 1.4 Flow-stopping equipment and components are described in terms of types and function. Range equipment – under pressure drilling and tapping machine, bag tube set, vent pipes, flame traps, inflation pump, pressure gauges, hand tools, breathing apparatus. 1.5 Equipment is described in terms of potential hazards of incorrect operation and the steps to avoid them are described in accordance with company procedures. 1.6 Resource requirements are identified and sourced in accordance with company procedures. Range plant, tools, materials, documentation, system components, personnel, communication equipment. New Zealand Qualifications Authority 2016 10986 version 5 Page 3 of 4 Element 2 Prepare for flow stopping and use flow-stopping bags. Performance criteria 2.1 Safety and environmental hazards are identified, then isolated, removed, or minimised, in accordance with company procedures. Range 2.2 Flow-stopping equipment and materials are prepared and installed in accordance with company procedures and manufacturer’s instructions. Range 2.3 may include – under pressure drilling and tapping machine, bag tube set, vent pipes, flame traps, inflation pump, pressure gauges, hand tools, breathing apparatus. Flow is stopped using flow-stopping equipment in accordance with company procedures and manufacturer’s instructions. Range 2.4 may include – signage, barriers, personal protective equipment, safe access and egress, gas escape, fire, explosion, asphyxiation, other utilities, temporary traffic control, environmental protection, excavations. drilling, flow-stopping bags, venting. Flow-stopping equipment and materials are removed in accordance with company procedures and manufacturer’s instructions. Range may include – under pressure drilling and tapping machine, bag tube set, vent pipes, flame traps, inflation pump, pressure gauges, hand tools, breathing apparatus. Element 3 Reinstate site. Performance criteria 3.1 Equipment and materials left temporarily on site are stored safely and securely, or arrangements are made for their collection in accordance with company procedures. 3.2 Tools, equipment, and materials are removed from site in accordance with job requirements and company procedures. 3.3 Worksite is reinstated and made safe in accordance with company procedures. New Zealand Qualifications Authority 2016 10986 version 5 Page 4 of 4 Element 4 Complete reporting and documentation. Performance criteria 4.1 Information is communicated to other parties, both internal and external, in accordance with company procedures. Range 4.2 may include but is not limited to – special conditions, completion notice, additional work. Records and documents are completed and processed in accordance with company procedures. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the NZ Motor Industry Training Organisation (Incorporated) (MITO) info@mito.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016