Natty Boh Building
Baltimore , Maryland
Eric Singley
Penn State University
Architectural Engineering
Location
Natty Boh Building
Brewers Hill
Baltimore , Maryland
Penn State AE Schematic Lighting Proposal Eric Singley
Project Information
Building Character:
Old home of the Gunther Brewing Company.
Consists of 6 sections of differing heights.
Declared a historic place in 2002.
Building Statistics:
Overall Building Size : 189,550 ft 2.
Maximum Height : 9 stories
Multi-purpose: office, storage, residential, commercial
Penn State AE Schematic Lighting Proposal
Natty Boh Building
Eric Singley
Design Spaces
Large Work Space
Friday’s Day Care Center
Circulation Space
Canton Self Storage Lobby
Natty Boh Building
Special Purpose Space
Countrywide conference room
Outdoor Space
Parking lot and rear facade
Penn State AE Schematic Lighting Proposal Eric Singley
Day Care Center
Penn State AE
Natty Boh Building
Space Properties
Floor area 4092 ft 2 .
Exposed ceiling at 14 ft.
Large windows on east and west walls.
Interior partitions dividing kitchen and storage areas.
Space Tasks
Primarily play and learning area for small children.
Light kitchen use.
Schematic Lighting Proposal Eric Singley
Day Care Center
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Day Care Center
Natty Boh Building
Design Goals
Separate the spaces by function with lighting.
Create a more ‘playful’ atmosphere within the child care area.
Make use of the large windows to introduce daylighting to the space.
Flynn mode – Relaxed.
Power Density
1.5 Watts per square foot allowed.
Penn State AE Schematic Lighting Proposal Eric Singley
Day Care Center
Design Solution
Drop ceiling to 9’.
Recessed linear fluorescent downlights in walkways.
Recessed CFL downlights in childrens’ area and kitchen.
Under-cabinet lights in kitchen.
LED color spots on columns.
Penn State AE Schematic Lighting Proposal
Natty Boh Building
Eric Singley
Day Care Center
Natty Boh Building
Daylight Integration
Kitchen lights and windowside children’s are lights on their own circuit. Use
Photometric sensor with manual override for control.
Penn State AE Schematic Lighting Proposal Eric Singley
Lobby
Space Properties
Floor Area ≈ 2500 ft 2
Ceiling at 8 ft and 21.5 ft
No windows
Entrances on both levels
Space Tasks
Light office work
Display of model storage unit
Sales / Receptionist desks
Penn State AE Schematic Lighting Proposal
Natty Boh Building
Eric Singley
Lobby
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Lobby
Design Goals
Accentuate the double height ceiling.
Direct customers from entrances to the sales desk.
Provide a non-complex design solution.
Flynn mode – Spacious.
Power Density
1.3 Watts per square foot allowed.
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Lobby
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Lobby
Design Solution
CFL downlights over desks.
Recessed CFL downlights in 9’6” portion lower ceiling.
Linear fluorescent wallwash along open wall.
Wallwashers on 21 ft walls to accent their height.
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Conference Room
Space Properties
Floor Area : 150 ft 2
Ceiling at 8 ft
Conference table with chairs
No windows
Space Tasks
Professional and Casual conferences
Possible light video conferencing
Penn State AE Schematic Lighting Proposal
Natty Boh Building
Eric Singley
Conference Room
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Conference Room
Natty Boh Building
Design Goals
Create a comfortable yet professional environment.
Provide flexibility to accommodate different uses. Including:
Presentations
Video conferencing
Roundtable discussion
Flynn mode – Spacious/Focused
Power Density
1.5 Watts per square foot allowed
Penn State AE Schematic Lighting Proposal Eric Singley
Conference Room
Natty Boh Building
Roundtable Discussion
Recessed CFL downlights on the conference table.
Linear Fluorescents washing walls and ceiling to provide ambient lighting.
Penn State AE Schematic Lighting Proposal Eric Singley
Conference Room
Presentation
Ambient lighting remains on.
Reduce the number of downlights on the conference table.
Two spot lamps on podium.
Penn State AE Schematic Lighting Proposal
Natty Boh Building
Eric Singley
Conference Room
Natty Boh Building
Video Conferencing
Dimmed ambient lighting.
Spot lamps on individual faces.
Downlights on table reduced further.
Penn State AE Schematic Lighting Proposal Eric Singley
Exterior
Penn State AE
Natty Boh Building
Space Properties
Ground Area : 37,050 ft 2
Surrounded on 3 sides by buildings
Historically significant
Space Tasks
Parking for Natty Boh Building
Entrance to the building
Schematic Lighting Proposal Eric Singley
Exterior
Natty Boh Building
Penn State AE Schematic Lighting Proposal Eric Singley
Exterior
Natty Boh Building
Design Goals
Provide sufficient light to allow drivers to read signs and see parking lines.
Call attention to the building entrances.
Achieve 100% Dark Sky compliance.
Maintain similar luminaire appearance.
Power Density
0.3 Watts per square foot allowed
Penn State AE Schematic Lighting Proposal Eric Singley
Exterior
Natty Boh Building
Design Solution
Spotlight building entrances.
Prevent spill into windows.
Keep light poles on existing islands.
Penn State AE Schematic Lighting Proposal Eric Singley