Office of Contract Management and Vendor Services Rio Hondo Community College 3600 Workman Mill Road, A-103 Whittier, CA 90601-1699 Ph: 562/908-3413 & Fax: 562/908-3462 Bid # 2045- Bookstore and Print Shop Renovation Project DSA #03-116477 Addendum # 1 April 13, 2016 To: All Prospective Bidders THE FOLLOWING REVISIONS AND/OR CLARIFICATIONS SHALL BE MADE TO THE BIDDING REQUIREMENTS AND CONTRACT DOCUMENTS. REVISE AND AMEND THE DOCUMENTS FOR THE ABOVE NAMED PROJECT IN ACCORDANCE WITH THIS ADDENDUM. THE BID SHALL REFLECT THESE ADDENDUM CHANGES AND EACH BIDDER SHALL MAKE REFERENCE IN THEIR BID TO THIS ADDENDUM. ALL BIDDING REQUIREMENTS AND CONTRACT DOCUMENTS SHALL APPLY TO THIS ADDENDUM AS ORIGINALLY INDICATED IN THE APPLICABLE PORTIONS OF THE CONTRACT DOCUMENTS, UNLESS OTHERWISE MODIFIED BY THIS ADDENDUM. Acknowledge receipt of this Addendum in the space provided on Document 00210 – Bid Proposal. Failure to do so may result in the bid being deemed non-responsive. The Addendum consists of the following changes: 1. ADMINISTRATIVE ITEMS: 1.1 Access Restrictions and Special Considerations ATM – Automated Teller Machine - Prior to mobilizing, the Contractor will establish a ‘point contact’ with the ATM servicing company. The Contractor will provide continuous access for the convenience of the ATM servicing company to the room labeled “JAN” near Gridlines G/15a for routine maintenance and repair of the ATM. The Contractor will provide escort and PPE (personal protection equipment), if required by conditions or the Contractor’s IIPP. - Utilities serving the ATM must remain in continuous operation. Outages will be permitted only as part of a general building outage and must be coordinated with the credit union and the ATM service company at least one week prior to the outage. - The Contractor must maintain continuous access to the ATM for public use. RIO HONDO COMMUNITY COLLEGE – Bid #2045 Page 1 of 5 ADDENDUM NO 1 April 13, 2016 1.2 Access to Occupied Offices South of Gridline H - Note the Plumbing work shown in Details 3 and 4 on Sheet P101. Work in the occupied office area must be coordinated with the Project Manager, scheduled and approved by the Project Manager two weeks in advance. Access by the Contractor may be continuously monitored. - For planning purposes, the Contractor should assume that work will be done outside normal working hours. - If the work cannot be completed during a single, scheduled and approved duration, the Contractor will restore the room to its original condition, suitable for normal occupancy, all utilities operational, clean, and ceiling tiles installed. - The Contractor cannot assume the area will be available ‘on demand’ and should plan for discontinuous durations of availability. 1.3 Access to Walk-In Record Storage Vaults - Two walk-in record storage vaults are shown on the plans. Both vaults are on the First Floor. One is near Gridlines G/17; the other is near Gridlines E/16. - Access to the vault interiors is restricted. Work in the vaults must be coordinated with the Project Manager, scheduled and approved by the Project Manager two weeks in advance. Access by the Contractor will be continuously monitored. - For planning purposes, the Contractor should assume that work will be done during normal working hours. - Access to the stored records by College staff must be continuous. Work in the room labeled “Clerk Room”, near Gridlines H/17, must be made safe for staff access. The Contractor will provide escort and PPE (personal protection equipment), if required by conditions or the Contractor’s IIPP. 1.4 Access for Installation of Fire Alarm System In Occupied Areas - For planning purposes, the Contractor should assume that work will be done outside normal working hours. - Work in the occupied office areas and classrooms must be coordinated with the Project Manager, scheduled and approved by the Project Manager two weeks in advance. Access by the Contractor may be continuously monitored. - If the work cannot be completed during a single, scheduled and approved duration, the Contractor will restore the room to its original condition, suitable for normal occupancy, all utilities operational, clean, and ceiling tiles installed. - The Contractor cannot assume the area will be available ‘on demand’ and should plan for discontinuous durations of availability. - A schedule of classroom usage is available and the Contractor may access classrooms to complete the work when not being used by the College. Access can be planned from fifteen minutes after scheduled completion of class and classrooms must be vacated by the Contractor fifteen minutes before the scheduled start of any class. 1.5 Low Voltage Service and Power to Security Office - Low voltage and power service to the Security Office must not be interrupted. - Identify low voltage wiring serving the Security Office area before commencing demolition and protect during demolition and construction. RIO HONDO COMMUNITY COLLEGE – Bid #2045 Page 2 of 5 ADDENDUM NO 1 April 13, 2016 2. SPECIFICATIONS: NONE 3. DRAWINGS: 3.1. ARCHITECTURAL 3.1.1 Sheet A090 (OVERALL DEMOLITION PLAN) · Key notes and 19 and 16 are revised. 3.1.2. Sheet A101 (ENLARGED FLOOR PLAN): · Clarification - New Flooring at existing corridor is identified – Legend is updated. 3.1.3. Sheet A102 (ENLARGED REFLECTED CEILING PLANS): · Key Notes 1 and 5 are revised. New Ceiling in the corridor instead of Patch and replace existing Ceiling Tile. 3.1.4. Sheet A110, (ENLARGED PLANS AND ELEVATIONS): · Key Notes 12 and 12A are corrected. Surface mounted toilet tissue dispenser type is now addressed correctly for male and female. 3.1.5. Sheet A120, (EXTERIOR STOREFRONT): · Louver is shown on the Elevation to match Mechanical plans. 3.1.6. Sheet A600, (WALL DETAILS & FIRESTOP): · Note on Detail 28 is added to match note from Sheet A120 of the Storefront attachment to HSS. 3.1.7. Sheet A610, (SUSPENDED CEILINGS): · Rated Sealant note is removed at non rated storefront condition – Detail 10 is revised. · Rated Sealant note is added at rated wall condition – Detail 20 is revised. 3.1.8. Sheet A650 (DOORS / WINDOWS SCHEDULES): · To the counter near Door N12C Reference to detail 15/A650 is added. · “WINDOW TYPES AND SCHEDULE” reference Details are corrected. · “DOOR TYPES AND SCHEDULE” clarification notes are added at Doors # E1 and E2. · Notes for Clarification are added on Details 12, 13, 14 and 20. 3.2. MECHANICAL 3.2.1 Sheet M020 · Existing thermostats are existing to be relocated as shown on the remodel plan. RIO HONDO COMMUNITY COLLEGE – Bid #2045 Page 3 of 5 ADDENDUM NO 1 April 13, 2016 3.2.2 Sheet M101 · Thermostat has been relocated to adjacent wall. 3.2.3 Sheet M301 · Note for the Pre-tensioned and Post-Tensioned concrete has been removed. The ½” diameter Hilti KB-TZ has been changed to 3/8”. 3.3. PLUMBING 3.3.1 Sheet P001 · General note number 4 applies to the plans. · 4 bands have been added to the No-Hub fittings in the Pipe Material Schedule. 3.3.2 Sheet P100 · Saw cutting has been added to the plumbing floor plans. 3.3.3 Sheet P101 · Pipe has been moved down out of the ATM room. · Vent line connection has been added. 3.3.4 Sheet P200 · The stiffeners dimensions are to be 1-5/8” x 1-5/8” x 2”. · Detail 4 is showing a plan view and an elevation view of the rod stiffener. These call outs have been added to the detail. Clarification to bidders: The pan does not have a secondary drain; there is a moisture sensor. 3.4 ELECTRICAL 3.4.1 Sheet E201 · Power for two vending machines has been added to plans. · Additional power and data has been added Clerk Room. 3.4.2 Sheet E301 · Clarification is provided on connecting new light fixtures to existing emergency and non-emergency corridor circuits. 3.5. FIRE ALARM 3.5.1 Sheet FA101 · Ceiling types for existing vault has been revised to accurately indicate existing conditions. RIO HONDO COMMUNITY COLLEGE – Bid #2045 Page 4 of 5 ADDENDUM NO 1 April 13, 2016 4. BIDDERS QUESTIONS: RESPONSE TO QUESTIONS FROM BIDDERS The following questions were received as Bid RFIs. Enclosed are responses to each. The following revisions and clarifications shall become a part of the Contract Documents upon award of Bid. All bidders are required to incorporate all necessary changes, additions, or deductions into their proposals. 3.1.1 Q: Plan sheet A-102, north exterior wall of Print Shop Rm. 11 indicates detail 15/A610 Sim at one window. Does this detail apply elsewhere? A: This detail applies for all exterior windows at north wall of Print Shop Rm. 11. 5. ENCLOSURES: Enclosures: § REVISED Drawing A090 (1 page) § REVISED Drawing A101 (1 page) § REVISED Drawing A102 (1 page) § REVISED Drawing A110 (1 page) § REVISED Drawing A120 (1 page) § REVISED Drawing A600 (1 page) § REVISED Drawing A610 (1 page) § REVISED Drawing A650 (1 page) § REVISED Drawing M020 (1 page) § REVISED Drawing M101 (1 page) § REVISED Drawing M301 (1 page) § REVISED Drawing P001 (1 page) § REVISED Drawing P101 (1 page) § REVISED Drawing P200 (1 page) § REVISED Drawing E201 (1 page) § REVISED Drawing E301 (1 page) § REVISED Drawing FA101 (1 page) END OF ADDENDUM # 1 RIO HONDO COMMUNITY COLLEGE – Bid #2045 Page 5 of 5 ADDENDUM NO 1 April 13, 2016 F G H J K L 14 OFFICE OFFICE 4 4 OFFICE OFFICE OPEN AREA SECURITY OFFICE 13 (E) CORRIDOR 19 9 15a 10 10 OFFICE OFFICE OFFICE OFFICE OFFICE 14 14 OFFICE JAN. 11 11 12 12 OWNER: LOUNGE OFFICE OFFICE OFFICE OFFICE RIO HONDO COLLEGE OFFICE OFFICE OFFICE 3600 Workman Mill Rd, Whittier, CA 90601 E CLIENT ADDRESS: D BOOKSTORE AND PRINT SHOP C PROJECT NAME: B 16 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 4 OFFICE JAN. 31, 2017 (E) BACK OFFICES 17 IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES (E) VAULT EVENING WEEKEND COLLEGE 03-116477 A# AC 17 2 1 16 1 6 7 8 3 FLS SS DATE REVISIONS: 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 N E U H TR RT O N OVERALL DEMOLITION PLAN A. FILED VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. 3 2 4 EXISTING CASEWORK TO BE DEMOLISHED C. DEMOLITION DEBRIS MUST BE PROMPTLY REMOVED FROM THE SITE. DEBRIS REMOVAL MUST BE COORDINATED WITH THE OWNER / LANDLORD. 5 EXISTING CONDUITS AT STOREFRONT TO BE RE-ROUTED, SEE ELECTRICAL DRAWINGS. D. WHERE DEMOLITION IS TO OCCUR ADJACENT TO OCCUPIED AREAS, CONSTRUCT ALL NECESSARRY CONSTRUCTION BARRIERS, AND TEMPORARY DUST/NOISE PARTITIONS. 6 EXISTING DRAIN PIPE TO REMAIN, TO BE SANDED AND PAINTED WHITE. EXISTING TAPE TO BE REMOVED. E. ALL SALVAGE ITMES SCHEDULED FOR RE-USE MUST BE CAREFULLY REMOVED, TAGGED, AND STORED UNTIL RE-USE. CLAEN AND RECONDITION AND SALVAGE ITEMS NOTED OR SCHEDULED TO BE RE-USED. 7 EXISTING LIGHT FIXTURE TO BE REMOVED 8 EXISTING CONDUIT TO BE REROUTED (TBD). 9 OPEN UP WALL FOR NEW DRINKING FOUNTAIN. 10 OPEN UP CEILING FOR TRANSITION DUCTS. 11 REMOVE WALL TILES AND SUBSTRATE DOWN TO STUDS. 12 REMOVE FLOOR TILES AND MORTER BED, NEW FLOOR DRAIN TO BE PROVIDED. 13 EXISTING ROLL UP DOOR TO BE DEMOLISHED. 14 EXISTING WINDOWS TO BE DEMOLISHED. EXISITNG FILMS TO BE COORDINATED WITH LOCAL REPRESENTATIVE. 15 EXISTING STOREFRONT TO BE DEMOLISHED. 16 EXISTING WINDOWS TO BE DEMOLISHED. 17 EXISTING STOREFRONT TO REMAIN. 18 EXISTING 5" CONCRETE WALL TO REMAIN, REPLACE EXISTING GYP. BOARD AT INTERIOR SIDE. REMOVE EXISTING 5" BRICK VENEER AT EXTERIOR. 19 DEMOLISH EXISTING FLOOR AND CEILING 6 1 SHOULD THE OWNER DECLINE TO ACCEPT AND PROVIDE STORAGE FOR ANY OF THE ABOVE, THEY SHALL BECOME PROPERTY OF THE CONTRACTOR AND MUST BE PROMPTLY REMOVED FROM THE SITE. 3 G. REMOVE ALL ATTACHMENTS FOUND ON PARTITION FACES AND CEILIMGS, AND TURN OVER THE OWNER, I.E. SURFACE MOUNTED TOILET ACCESSORIES, (SOAP DISPENSERS) CUBICLE CURTAIN TRACKS, T.V. WALL MOUNTING, BTRACKETS, ETC. H. REMOVAL OF ANY ANTENNAS OR COMPUTER AND TELEPHONE CABLE AND / OR SYSTEM BOARDS MUST BE COORDINATED AND SCHEDULED WITH THE OWNER. 15 DEMOLISHED EXISTING PORTION OF WALL WITH BRICK. STOREFRONT DOOR / WINDOW BE TO REPLACED B. DEMOLITION QUANTITIES ARE UNCLASSIFIED EXCEPT WHERE EXISTING CONSTRUCTION IS GRAPHICALLY DESIGNATED AND / OR NOTED TO REMAIN. WHERE PARTITIONS, CEILING, FLOORS ETC. ARE SHOWN TO BE REMOVED, DEMOLITION SHALL BE INCLUSIVE OF MEP SERVICES / UTILITES CONTAINED WITHIN, UNLESS SCHEDULED OR NOTED TO REAMAIN OR BE EXTENDED FOR ADDITIONAL DEMOLITION AND / OR SALVAGE REQUIREMENTS SEE CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DOCUMENTS. SEE NEW CONSTRUCTION DOCUMENT TIE-INS TO EXISTING SYSTEMS. SERVICES AND METERIALS TO FULLY DETERMINED ACTUAL DEMOLITION LIMITS. F. THE OWNER RESERVES THE RIGHT TO RETAIN THE FOLLOWING SALVAGE ITEMS, IF SO NOTIFIED (AND IF NOT SPECIFICALLY INCORPORATED, AND STORE IN OWNER DESIGNED SPACE (ON CAMPUS) THE FOLLOWING ITEMS: - ELECTRICAL FIXTURES AND DEVICES - DOORS, FRAMES AND HARDWARE - MECHANICAL GRILLS / DIFFUSERS - PLUMBING FIXTURES AND TRIM - MILLWORK AND CASEWORK UNITS 7 1 I. PROTECT BY APPROPRIATE MEANS ALL EXISTING CONSTRUCION FINISHES, AND EQUIPMENT THAT IS TO REMAIN ALL DAMAGED ITEMS / FINISHES MUST BE REPAIRED / RESTORED TO THEIR ORIGINAL (PREDAMAGED) CONDITION. J. DEMOLITION REQUIRING AIR HAMMERS OR OTHER LOUD NOISE GENERATING EQUIPMENT MUST BE CAREFULLY COORDINATED AND SCHEDULED WITH THE OWNER. WORKING HOURS FOR SUCH ACTIVITY WILL BE RESTRICTED. K. IN EXISTING SPACES WHERE PARTITIONS ARE SHOWN TO BE REMOVED, REMOVE EXISITNG ABUTTING FLOOR FINISHES AND CEILINGS AS WELL UNLESS SPECIFICALLY NOTED TO REMAIN. L. ALL PENETRATIONS FOUND IN EXISTING CHASES AND FIRE RATED PARTITIONS OR SHAFTS, NOT SPECIFICALLY CALLED OUT, MUST BE PATCHED / FIRESAFED TO MEET THE REQUIRED FIRE ASSEMBLY RATING. M. UTILITY SHUT DOWNS AND ALL SERVICE OUTAGES MUST BE SCHEDULED WITH THE OWNER ONE (1) WEEK IN ADVANCE. EXISTING PIPES TO BE DEMOLISHED IN COORDINATION WITH RIO HONDO COLLEGE. 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A090 SHEET TITLE: OVERALL DEMOLITION PLAN 1 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 O. AFTER REMOVAL OF EXISTING CONSTRUCTION OR FINISHES, PATCH OR REPAIR EXISTING SUBSTRATES REMAINING AS REQUIRED TO RECEIVE THE SCHEDULED FINISH. DEMOLITION NOTES DATE ISSUED: NOT PART OF THE SCOPE N. WHERE IMBEDDED ITEMS OR PLUMBING FIXTURES, ETC. ARE REMOVED, PATCH REPAIR THE EXISTING CONSTRUCTION TO REMAIN TO MATCH AND TO MAINTAIN THE STRUCTURAL AND / OR FIRE PROTECTION INTEGRITY OF THE WALL. DEMOLITION AT EXTERIOR 1 EXISTING DOOR TO REMAIN TO BE DEMOLISHED 3 1/8" = 1'-0" KEY NOTES LEGEND SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. WALLS PT-1: FRAZEE SUNNY BEIGE : EGGSHELL - (TBC) PT-2: FRAZEE GEORGIA WHITE: EGGSHELL - (TBC) (N) 1-HR RATED WALL SEE DETAIL FLOORING (N) PARTIAL HEIGHT PARTITION WALL SEE DETAIL 18 / A600 Color copier 11 (N.I.C.) 1138 SF LVT / RWB MIN. CLR. (N.I.C.) New Coiling Counter Door Xerox Nuvera FEX 4" 3' - 0" 4' - 8" PRINT SHOP Work Table (N.I.C.) (E) CONCRETE SHEAR WALL N12B CR paper cab. work table (N.I.C.) 7' - 10" SUBSTRATE TB-GYPBD: PLAS: GYPBD: 5/8" TYPE X GLASS MAT FACE TILE BACKER (TBC) PLASTER (TBC) 5/8" TYPE X (TBC) 32" MIN. W3 5' - 4" 7' - 10" (N.I.C.) xerox 4595 306 SF LVT / RWB WALL BASE RWB: TEXTURE OP: FEX SEMI RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER, SEE DETAIL 23/A-640 ER EXIT ROUTE SIGN - SEE DETAIL 12/G-003 RS ROOM NUMBER SIGN - SEE DETAIL 4/G-003 2.5 WALL TYPE NUMBER, PARTIAL HEIGHT 2.5" METAL STUD W/ 5/8" TYP X GYPSUM BORAD EACH SIDE, SEE 11 A600 4.1 WALL TYPE NUMBER, PARTIAL HEIGHT 4" METAL STUD WITH 5/8" TYP X GYPSUM BORAD EACH SIDE, SEE 18 A600 4.2 WALL TYPE NUMBER, FULL HEIGHT 4" METAL STUD WITH 5/8" TYP X GYPSUM BORAD EACH SIDE, SEE 14 A600 6.2 WALL TYPE NUMBER, FULL HEIGHT 6" METAL STUD WITH 5/8" TYP X GYPSUM BORAD EACH SIDE, SEE 14 A600 8.2 WALL TYPE NUMBER, FULL HEIGHT 8" METAL STUD WITH 5/8" TYP X GYPSUM BORAD EACH SIDE, SEE 14 A600 8.3 EXTERIOR WALL 8" METAL STUD WITH 5/8" TYP X GYPSUM BORAD ONE SIDE, PAINTED 7/8" STUCCO SMOOTH FINISH AT THE EXTERIOR SIDE. SEE 21 22 PAINT COLOR: TO BE DETERMINED 20 A600 A600 A600 RUBBER WALL BASE (PER SPECS) (TBC) (TBD) LIGHT ORANGE PEEL - (TBC) TO BE CONFIRMED TO BE DETERMINED 6.2 FURNITURE BY VENDOR (O.F.O.I). BUILT-IN ELEMENTS SHALL COMPLY WITH ACCESSIBILTY CODE REQUIREMENTS. 1 NEW STOREFRONT WINDOWS 6.2 STORAGE 10 269 SF LVT / RWB 44" MIN. CLR. LEGEND KEY NOTES freeflow 1' - 6" CARD READER AT 48" A.F.F. FINISH LEGEND 2 4.1 MIN. CLR. CR WALL TYPES: 1 (N.I.C.) xerox 4595 PER SPECS SOFFITS AND RESTROOMS - (TBC) N11 12 3' - 0" 6.2 STORAGE RACKS FURNITURE BY O.F.O.I (N.I.C.) 1 CEILING ACT-1: GYPBD: 7' - 0" 30" HEIGHT FURNITURE DESKCOUNTER (N.I.C.) 4' - 0" work table (O.F.O.I) 16' - 5" PRINT SHOP PUBLIC LOBBY 2' - 0" 5' - 0" 4' - 3 1/2" 6' - 0" VINYLE TYLE: NATURAL CREATIONS MYSTIX TP769 CHROMA STONE SPAR DOOR NUMBER, SEE DOOR SCHEDULE N 9' - 4" 4.1 4' - 9" N12C VT: LVT NOTES: Provide 25 sq ft of flooring and 20 lineal feet of base of each material specified under provisions of Section 01770. ACCESSIBLE APPROACH 30x42 CLEAR SPACE 7' - 0" N12A E CR N10 1 HR E (E) CORRIDOR - 19' - 10" 990 SF VT 10' - 3 1/2" EXISTING EXIT DOOR WITH NEW PANIC HARDWARE 29' - 1" +/- E4 1 43' - 0 1/2" 3600 Workman Mill Rd, Whittier, CA 90601 (N.I.C.) SEE SPECS TBD FURNITURE (O.F.C.I) UNLESS OTHERWISE NOTED CLIENT ADDRESS: Xerox Nuvera MANUFACT: COLOR: (E) CONCRETE WALL TO REMAIN - NO NEW WORK BOOKSTORE AND PRINT SHOP "NOT AN ACCESSIBLE EXIT" DOOR SIGN LVT: 30x30 work table (E) PARTITION WALL - NO NEW WORK OWNER: (N.I.C.) 19' - 8" Work Table (N.I.C.) digital duplicator 13' - 9 1/2" +/- HAND WASH SINK. SEE ACCESSIBLE LAVATORY DET. 3 ON SHEET _GEN-4 Drill (N.I.C.) padding MIN. (N.I.C.) Stapler 4' - 6" Paper Cutter 3' - 0" E1 (N) FULL HEIGHT PARTITION WALL SEE DETAIL 14 / A600 PROJECT NAME: CARPET NOTES: A. Carpet shall be securely attached and have a firm cushion, pad, or backing or no cushion or pad. It shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. Pile height shall be ½” maximum per CBC Section 11B-302.2 B. Exposed edges shall be fastened to floor surfaces and shall have trim on the entire length. Carpet edges shall comply with CBC section 11B303 per CBC Section 11B-302.2. RIO HONDO COLLEGE CPT-1: MANUFACT: SEE SPECS COLOR: TBD "EMERGENCY EXIT ONLY ALARMED DOOR" SIGN 17 A600 76' - 4" 1 HR 1 HR W1 W1 W2 W1 1 HR 15a 4' - 10 1/2" 9' - 9 1/2" 4' - 0" 2' - 7 1/2" TEXTBOOKS JAN. 31, 2017 11' - 4 1/2" SCHOOL SUPPLIES IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES VENDING MACHINE NOTE: AN ACCESSIBLE ROUTE OF COMMON USE CIRCULATION PATHS SHALL BE PROVIDED IN THE STAGING SPACE. THE CLEAR WIDTH FOR AISLES SHALL BE 36" MIN. IF SERVING ELEMENTS ON ONLY ONE SIDE, AND 44" MIN. IF SERVING ELEMENTS ON BOTH SIDES. 03-116477 A# 1 5' - 0" 44" MIN. TYP. AC CLEARANCE 25' - 10" VENDING MACHINE FLS SS DATE INFO DESK & eFOLLETT REVISIONS: STAGING 1 4.2 7 GENERAL BOOKS 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 TYP. 4' - 0" 1502 SF LVT / RWB 24' - 2" 9' - 5 1/2" 15 1' - 0" 4458 SF CPT-1 / RWB MIN. N06 N05 4.1 A110 9' - 0" 8' - 4 1/2" 9' - 4" 4.1 CURTAIN AIR COOLER OFFICE 6 5 72 SF CPT-1 72 SF CPT-1 E2 TABLES NON EMBLEMATIC CLOTHING GIFTWARE 4' - 6" CURTAIN AIR COOLER OFFICE 6' - 4 1/2" 16 9' - 0" 4' - 0" DATE ISSUED: 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A101 44"MIN. CLEAR. 1 TYP. 4.1 VAULT CLERK ROOM 4 3 338 SF (E) 238 SF LVT / RWB 4.2 4.1 CURTAIN AIR COOLER WEEKEND COLLEGE 2 277 SF LVT / RWB E 4.2 (E) 17' - 9 1/2" 11' - 9" 14' - 1 1/2" TECHNOLOGY CENTER CURTAIN AIR COOLER TABLES 4.1 SHEET TITLE: ENLARGED FLOOR PLAN CONVENIENCE CARD SPINNER 44" MIN. CARD SPINNER FOLDING TABLES FOR RUSH CLEARANCE 6' - 1" 76' - 2 1/2" 30-34" HEIGHT ACCESSIBLE TRANSACTION COUNTER PER DET. 16 / A640 (FOR REFERENCE ONLY) 1 TYP. 2' - 6" 2.5 1-DOOR 1-DOOR 1-DOOR 1-DOOR UPRIGHT UPRIGHT COOLER COOLER FREEZER FREEZER 12 "EMERGENCY EXIT ONLY ALARMED DOOR" SIGN FOLLETT BOOKSTORE 9' - 8" 4.1 4' - 6" 30-34" HEIGHT ACCESSIBLE TRANSACTION COUNTER PER DET. 16 / A640 (FOR REFERENCE ONLY) N07 30" X 48" CLEAR SPACE 6' - 5" 2' - 0" FOLDING TABLE FOR RUSH 4' - 0" 30" X 48" CLEAR SPACE 30" X 48" CLEAR SPACE FEX 1 A120 30" X 48" CLEAR SPACE FEX Sim FEX N1E N1C E3 2 17 N1B 8.3 A120 N EXISTING - NO NEW WORK 2 3 MACARTHUR PLACE, SUITE 850 G H J K T 949.809.3380 E U H TR RT O N L ENLARGED FLOOR PLAN 1/4" = 1'-0" 1 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. NOT PART OF THE SCOPE 2 A610 EXISTING CEILING TO REMAIN, PANELS TO BE PATCHED / REPAIR/ REPLACED, LIGHT FIXTURES TO REMAIN. GYPSUM BOARD CEILING 3 ROLLER SHADE 4 NO ROLLER SHADE SUSPENDED GRID W/ ACOUSTICAL TILE 1 5 3 NEW CEILING PER DETAIL 23 / A610 SAME HEIGHT AS ADJACENT AREA RECESSED CAN LIGHT FIXTURE, SEE ELECTRICAL EXIT LIGHT, SEE ELECTRICAL PRINT SHOP 9' - 0" 2 X 2 OR 2 X 4 RECESSED LIGHT FIXTURE, SEE ELECTRICAL RIO HONDO COLLEGE 11 LINEAR PENDANT OR CEILING MOUNTED LIGHT FIXTURE, SEE ELECTRICAL SUSPENDED LIGHT FIXTURE AT 8'6" HEIGHT, SEE ELECTRICAL SUPPLY, RETURN AND EXHAUST GRILLES, SEE MECHANICAL 9' - 0" PROJECTOR MOUNT, SEE ELECTRICAL PRINT SHOP PUBLIC LOBBY KEY NOTES OPEN TO STRCT. 12 LEGEND STORAGE OWNER: 10 3600 Workman Mill Rd, Whittier, CA 90601 Sim CLIENT ADDRESS: 1 BOOKSTORE AND PRINT SHOP 15 NOT USED. PROJECT NAME: 1 5 20 Sim JAN. 31, 2017 A610 IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 03-116477 A# AC FLS SS DATE REVISIONS: 10' - 0" 1 STAGING DESCRIPTION DATE GENERAL REVIEW 04-01-2016 7 9' - 6" OFFICE OFFICE 5 6 DATE ISSUED: 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A102 SHEET TITLE: ENLARGED REFLECTED CEILING PLANS 10 4 2 CLERK ROOM WEEKEND COLLEGE 3 2 8' - 0" A610 1 8' - 6" 4 N VAULT 10 E U H TR RT O N A610 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 ENLARGED CEILING PLAN 1/4" = 1'-0" 1 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. Sim 1 1 TYP. TYP. TYP. 16 11 3 11 3 11 3 3 _GEN-4 3' - 0" Sim 2' - 0" 1-a 8 9 1/4" = 1'-0" 1-b 11 1/4" = 1'-0" 1-d 1-c 10 1/4" = 1'-0" 20 1 3 2 3 17 4 11 4 11 3 15 3 3 TYP. 3 _GEN-4 8 5 Sim ELEV. C 3' - 4" MAX. ELEV. B 7 Sim 1 3/8" = 1'-0" 6 3/8" = 1'-0" ELEV. A 3/8" = 1'-0" ENLARGED WOMEN RESTROOM #4 - ELEVATIONS Sim 3' - 0" 2 A640 1/4" = 1'-0" - FIXTURE 1 NOT USED 2 OVERHEAD BRACED PARTITION, SEE SPECS, SEE DET. 14/A-64.41 FOR TYP ATTACHMENT 3 WALL-HUNG SOLID URINAL SCREEN, 42” HIGH X 18” DEEP 4 24" X 36" FRAMED MIRROR, BOBRICK B-290 2436 5 HAND DRYER, BRADLEY AERIX 2902-287400 6 PARTITION-MOUNTED TOILET TISSUE DISPENSER, BOBRICK B-386 7 PARTITION-MOUNTED SANITARY NAPKIN DISPOSAL, BOBRICK B-354 8 GRAB BARS FOR ACCESSIBLE TOILET (1-1/4" DIA. STAINLESS STEEL): 42" LENGTH @ SIDE WALL (BOBRICK B-5806X42) 36" LENGTH @ REAR WALL (BOBRICK B-5806X36) 9 1-1/4" DIA. STAINLESS STEEL GRAB BAR, 42", BOBRICK B-5806X42 10 UTILITY SHELF W/ MOP & BROOM HOLDER, BOBRICK B-239 X 34 11 SURFACE MOUNTED LIQUID SOAP DISPENSER, OFOI 12A SURFACE MOUNTED TOILET TISSUE DISPENSER, BOBRICK B-3471 FOR MEN ONLY. 12 SURFACE MOUNTED TOILET TISSUE DISPENSER, BOBRICK B-35745 FOR WOMEN ONLY WITH TAMPON TRASH DISPENSER. 1 13 RECESSED TOILET TISSUE DISPENSER, BOBRICK B-3888 14 RECESSED SANITARY NAPKIN DISPOSAL AND TOILET TISSUE DISPENSER, BOBRICK B-3094 15 RECESSED BABY CHANGING STATION MODEL @ KB110-SSRE HORIZONTAL PER DET. 16 SEMI-RECESSED SANITARY NAPKIN / TAMPON VENDOR, FREE OPERATION (BOBRICK MODEL #B3706) 17 SEMI-RECESSED CONVERTIBLE PAPER TOWEL DISPENSER / WASTE RECEPTACLE BY BOBRICK MODEL # B-3942 18 FLOOR DRAIN SHALL HAVE MAXIMUM 1/2" OPENINGS (TYP.) * REFER SHEET GEN-4 FOR MOUNTING HEIGHTS AND LOCATIONS FOR ALL ACCESSIBLE RESTROOM ACCESSORIES AND FIXTURES. 3/8" = 1'-0" 12 JAN. 31, 2017 3 _GEN-4 IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 03-116477 A# AC FLS SS DATE REVISIONS: 1 F EXISTING ATM MACHINE (NO NEW WORK) 15 _GEN-4 2' - 0" 15a FOR SIGNAGE SEE DETAIL 18 / _GEN-3 E FOR SIGNAGE SEE DETAIL 17 / _GEN-3 E (E) LOUNGE JAN. - - 1' - 6" 5 MIN. 5 1' - 6" 3 5 MIN. 5 N14 DATE ISSUED: 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A110 5 18 EQ. EQ. 11 12 18 ) R. CL . IN "M 4 15 (4 11 3' 1 11 2 4.1 TOILET ACCESSORIES KEY NOTES 1 NEW TOILET FIXTURE, SEE PLUMBING DRAWINGS. 2 NEW TOILET ACCESSORIES; SEE TOILET ACCESSORIES SCHEDULE ON THIS SHEET. 3 NEW WALL TILES, EXISITNG WALL TILES TO BE REMOVED. 4 NEW FLOOR TILES, EXISITNG FLOOR TILES TO BE REMOVED. 5 (N) BABY CHANGING STATION SIGNAGE PER DETAIL16 / _GEN-3 SHEET TITLE: ENLARGED PLANS AND ELEVATIONS 8 15 5' - 0" MIN. 12A 1' - 6" 16 8 5' - 1" EQ. 12 " 1/2 (E) 4' - 5 1/2" 3 17 10 12 4 (E) 16' - 10" 9 7 A110 30" X 48" CLEAR SPACE A110 4 EQ. EQ. 11 EQ. 1' - 6" 2' - 10 1/2" 8 4 17 3 6 1' - 8 1/2" 2' - 9 1/2" (E) WOMENS RR (E) MENS RR 5' - 0" 3' - 0" 1' - 8" 3' - 0" 1' - 6" N13 3 4 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 G 30" X 48" CLEAR SPACE 3/8" = 1'-0" 5 3' - 5" ELEV. D 3' - 0" 4 1 1' - 6" 3' - 0" 1' - 6" (E) 20' - 5" 1' - 6" 2' - 10" 1' - 6" 2' - 10" Sim 3 _GEN-4 15 3' - 4" STAGING #7 - VIEW D 12 3 _GEN-4 3' - 0" A640 3/8" = 1'-0" TYP. TYP. Sim A640 1/4" = 1'-0" ENLARGED WOMEN RESTROOM #4 - ELEVATIONS 2 2' - 11" OWNER: 3 _GEN-4 RIO HONDO COLLEGE 2' - 10" Sim 2' - 10" 3 _GEN-4 Sim 3600 Workman Mill Rd, Whittier, CA 90601 3 _GEN-4 8 CLIENT ADDRESS: 3 BOOKSTORE AND PRINT SHOP 1 PROJECT NAME: 5 Sim 2' - 10" 4 3 _GEN-4 4' - 0" MIN. 16 5' - 0" MIN. CLR. (E) 14' - 1" (E) 12' - 2" 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 ENLARGED EXITING RESTROOMS - FLOOR PLAN 1/4" = 1'-0" 1 KEY NOTES SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 22 HSS 4 x 8 x 1/4 HSS 4 x 8 x 1/4 FLAT TEMPERED TYP. HSS 4 x 8 x 1/4 FLAT HSS 4 x 8 x 1/4 HSS 8 x 8 x 1/4 TEMPERED, TYP. HSS 4 x 8 x 1/4 TEMPERED NEW EXTERIOR WALL 8" METAL STUD WITH 7/8" STUCCO SMOOTH FINISH AT THE EXTERIOR SIDE. COLOR TO BE DETERMINED EXISTING 5" CONCRETE WALL TO REMAIN REMOVE EXISTING 5" BRICK VENEER AND REPLACE IT WITH 400S162-43 STUD & 7/8" STUCCO SMOOTH FINISH COLOR TO BE DETERMINED TEMPERED, TEMPERED TEMPERED, TEMPERED TEMPERED TEMPERED TEMPERED EXISTING TO REMAIN Sim 14 A650 TEMPERED TEMPERED TEMPERED TEMPERED 17 TEMPERED EQ. NEW STOREFRONT DOOR AT EXISTNG OPENING NEW EXTERIOR WALL 8" METAL STUD WITH 7/8" STUCCO SMOOTH FINISH AT THE EXTERIOR SIDE. COLOR TO BE DETERMINED SEE DETAIL 28/A610 FOR STORFRONT FRAMING TEMPERED TYP. E3 + -- 8'-6" TO ALIGH WITH HSS 4 x 8 x 1/4 TEMPERED TYP. ADJACENT EXISTING MULLION A600 TEMPERED, TYP. ALIGNED 20 21 A600 A600 NEW STOREFRONT DOOR AT EXISTNG OPENING NEW STOREFRONT AT EXISTNG OPENING EXISTING OPENING EQ. A650 EQ. EQ. BOOKSTORE AND PRINT SHOP 3600 Workman Mill Rd, Whittier, CA 90601 1 EXISTING TO REMAIN HSS 4 x 8 x 1/4 ALIGNED 1 EXISTING TO REMAIN CLIENT ADDRESS: EXISTING TO REMAIN TYPICAL OWNER: NEW LOUVER COLOR TO MATCH ADJACENT PAINT AREA Y A120 LOUVER PER MECHANICAL PLAN TO BE PAINTED L PAINT PANEL AT NEW STOREFRONT AT PIPE PENETRATION IF NEEDED. WITH MULLION ON THE ADJACENT SIDE NEW MULLION TO BE PAINTED EXISTING TO REMAIN GLAZING TO BE CHANGED TO FRIT , MULLIONS TO BE PAINTED. K PROJECT NAME: J 1/2" = 1'-0" 8' - 9" TO BE ALIGNED H HSS 4 x 8 x 1/4 G RIO HONDO COLLEGE Y ELEVATION EQ. 28' - 6" NEW STOREFRONT (V.I.F) JAN. 31, 2017 SEE 28/A600 FOR STOREFRONT FRAMING (TYP.) NOTE: VERTICAL MULLIONS TO BE DIRECTLY ATTACHED TO HSS ABOVE W/ MIN. (2) 1/4" DIA. TEKS EA. SIDE AND TO CONCRETE BELOW WITH MIN. (1) TITEN HD EA. SIDE (3/8" DIA. W/ 4" EMBED.) EXTERIOR STOREFRONT - ELEVATION AND FRAMING IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 1/4" = 1'-0" 2 03-116477 A# AC FLS SS DATE REVISIONS: 1 VAULT DESCRIPTION DATE GENERAL REVIEW 04-01-2016 CLERK ROOM 4 3 338 SF (E) 238 SF LVT / RWB WEEKEND COLLEGE 2 DATE ISSUED: 01-08-2016 277 SF LVT / RWB PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A120 FEX FEX EXISTING 5" CONCRETE WALL TO REMAIN FEX 17 E3 ALIGN NEW STOREFRONT EXISTING EXTERIOR WALL- NO NEW WORK 6' - 5" NEW STOREFRONT G H 15' - 10" 6' - 2 1/2" AT EXISTING OPENING NEW STOREFRONT NEW FURRING 400S162-43 STUD & 7/8" STUCCO SMOOTH FINISH COLOR TO BE DETERMINED EXTERIOR STOREFRONT A120 NEW STOREFRONT 28' - 8" 28' - 8" AT EXISTING OPENING NEW STOREFRONT J SHEET TITLE: 2 NEW STOREFRONT K L 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 EXTERIOR STOREFRONT - ENLARGED FLOOR PLAN 1/4" = 1'-0" 1 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. (E) BEAM TYP. (4) 1/2" DIA. BOLT DRILL AND EPOXY IN (E) COLUMN USING SIMPSON SET XP ESR 2508 W/ 4" EMBED 4" EMBED 1/2" DIA. TITEN HD @ 24" O.C.W/ 3 3/4" EMBED. TORQUE AT 651B-TR 1 1/2" 4" 16 GA CLIP ANGLE w/ (3) #10 SMS TO BRACE AND (4) 0.145 DIA SIMPSON 'PDP' w/ 1.1/4" EMBED TO SLAB (ICC-ESR 2138) ((4) #12 SMS AT METAL DECK w/ NO FILL) 1 1 1/2" 351DES 1/4" 25 / A600 1/2" A.3 DRILL & EPOXY USING SIMPSON SET XP (ICC ESR-2508) W/3" EMBED DET. A 800T150-33 1/8 HSS PER PLAN WALL TYPE PER PLAN 4" STUD BEAM TO WALL 1 (2) 1/4" DIA. TEKS 6" MIN. FROM EA. END AT EA. SIDE. 12" O.C. C 3 A600 POST TO CONCRETE A 3 A600 TOP OF PARTITION STUD 5/8" TYPE X GYP BD, TYP (TO BE EXTENDED AT RATED WALL CONDITION) CLG. PER PLAN Sim Sim UL DESIGN NO. HW-D-0021 OR APPROVED EQUAL (@ FIRE RATED WALLS ONLY) A DIAGONAL BRACING ATTACHEMENT 1" = 1'-0" PARTITION FRAMING 25 1 1/2" = 1'-0" FULL-HEIGHT FRAMING 18 1 1/2" = 1'-0" TOP OF WALL @ CONC. DECK 14 3" = 1'-0" 4 C B HSS 4 x 8 x 1/4 OVERALL HSS 8 x 8 x 1/4 D HSS 4 x 8 x 1/4 STUD 18 A650 8 -6" SEE ELEVATION SIZE (E) CONCRETE FLOOR OR ROOF STRUCTURE SLOTTED TOP TRACK UES REPORT #283 1 MIN. SEE ELEVATION SEE ELEVATION EXTERIOR STOREFRONT FRAMING CLIP FLANGES & BEND 2" OF WEB FLUSH TO STUD 400T125-33 TRACK SEE SECT D 400S125-33 STUD (DOUBLE STUD FOR OPNG WIDTHS GREATER THAN 2'-0") #10 SMS NS & FS 3/8" DIA. HILTI KB-TZ WITH 4" EMBED. AT EACH END AND AT 16" O.C. MAX. WITH WEB STIFF AT EA. END TOP OF PARTITION STUD 28 1/4" = 1'-0" EXTEND WEBS OF HDR & CONNECT w/ (3) #10 SMS NS & FS 600S162-54 STUDS DOUBLE STUDS C INTERIOR FINISH PER FINISH SCHEDULE ACOUSTICAL BATT INSULATION, TYP, U.N.O. NO UNUSED KNOCKOUTS OR OTHER HOLES LEFT OPEN MEMBRANE AND THROUGH -WALL PENETRATIONS SEE NOTE BELOW. METALLIC OR RATED NONMETALLIC BOX 800S162-43 METAL STUDS AT 16" O.C. 8" WALL TYPE PER PLAN ACOUSTICAL INSULATION 0.145" DIA SIMPSON 'PDP' w/ 1.1/4" EMBED (ICC ESR-2138) @ 24 " OC 1/4" TO 1/2" JOINT FILLED WITH FIRE RATED ACOUSTICAL SEALANT AROUND BOX FACE FLANGE - DRYWALL OR PLASTER OVERLAPS FLANGE CONTINUOUS BOTTOM TRACK FIRE-RATED SEALANT @ FIRE-RATED WALLS, ACOUSTICAL SEALANT @ NON-RATED WALLS U465 - 1-HR - STEEL STUDS - NONBEARING WALL 1" MINIMUM REFER TO THE FOLLOWING CONFORM WITH REQUIREMENTS 1. PENETRATIONS TO CONFORM TO UL SYSTEM NUMBERS: WL, WWS & WWD SERIES AS APPLICABLE. SEE DETAIL 17/-. CLG. AT BOOKSTORE SIDE JAN. 31, 2017 IN DRYWALL OR PLASTER WALL IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 7/8" EXTERIOR CEMENT PLASTER O/ METAL LATH & TYVEK WRAP FOR ALL SILLS AND HEADERS AT OPNG WIDTHS AT OPNG WIDTHS 4'-0" & LESS FIRE RATED SHEET CAULKING ALL AROUND BACK AND SIDES OF BOX AT NON-RATED BOX AND 2-HR CONDITION ONE HOUR WALL NOTES FULL HEIGHT WALL A. U.L. U-465 OR B. CBC TABLE 720.1 - ITEM 13-1.1 (1 HR. RATING) 5/8" TYPE X GYP BD, TYP INTERIOR SIDE THERMAL BATT INSULATION CRIPPLE FOR ALL SILLS AND HEADERS UNFACED INSULATION ALL AROUND BOX 4" STUD EXTERIOR GLASS-MAT SHEATHING 600T125-33 TRACK SEE SECT D (2) #10 SMS NS & FS A600 CONT. SEALANT W/ BACKER HOD 6" 28'-6" STOREFRONT NEW OPENING Sim 5/8" TYPE X GYP BD, TYP C 6' - 0" 14 SEE DETAIL FOR ADDITIONAL INFORMATION DIM. POINT ON PLANS (U.N.O.) (1) LAYER 5/8" TYPE "X" GYP. BD. EACH SIDE, 1/2" 7' - 0" 18 A650 THICKNESS 4'-0" TO 12'-0" MAX EXTERIOR WALL AT TOP SECTION 3" = 1'-0" 22 ONE HOUR WALL DETAIL 3" = 1'-0" 17 ELECTRICAL BOX UP TO 16 SQ. IN. 3" = 1'-0" TYP. BOTTOM TRACK CONNECTION 12 3" = 1'-0" 1/2" MIN. AIR GAP SEE PLANS 400S125-33 STUD AT 16" O.C. UNLESS INDICATED OTHERWISE ON THE PLAN 400T125-33 MTL TRACK GAGE AT 4" STUD WALL (VARIES PER PLAN) TO MATCH STUDS #10 SMS @ 16" OC EACH SIDE MTL TRACK FLANGE = 1.25" MIN. FOR ALL SILLS AND HEADERS 1-12 5/8" TYPE "X" GYPSUM BOARD AT INTERIOR SIDE FIRE EXTINGUISHER AT FIRE EXTINGUISHER CABINET 7/8" THK. PORTLAND CEMENT PLASTER O/ METAL LATH & TYVEK STUCCO WRAP, ONE LAYER 5/8" TYPE "X" DRYWALL AT ONE HOUR RATING. TWO LAYERS REQUIRED AT TWO HOUR RATING. SEAL AIR TIGHT. CONSTRUCT OPENING PRIOR TO INSTALLATION OF FIXTURE. WIDTH WINDOW OR OTHER OPENING (1) LAYER 5/8" TYPE "X" GYP. BD. (SEE NOTE BELOW) INTERIOR FINISH PER FINISH PLAN/ SCHEDULE STUDS THERMAL BATT INSULATION WHERE INDICATED BY "A" ACOUSTICAL SEALANT ALL AROUND PERIMETER C #10 SMS AT EA LEG OF CLIP AS SHOWN DOUBLE STUDSFASTEN TO TOP & BOTT TRACK w/ #10 SMS EACH FLANGE EA SIDE 3 A600 SEAL ANY CONDUIT AT BOX BACKING PENETRATION D R-19 THERMAL BATT INSULATION ELECTRICAL BOX OVER 4" X 8" CABINET, FIXTURE OR ACCESSORY IN DRYWALL OR PLASTER B SECTION Sim EXISTING WALL (SHOWN GRAY) IN RATED WALL CONSTRUCTION WALL ELEVATION INTERIOR WALL FRAMING DETAIL 1" = 1'-0" EXTERIOR WALL DETAIL 27 3" = 1'-0" 21 ELECTRICAL OR FIXTURE CABINET 3" = 1'-0" 16 TYPICAL FURRED WALL 3" = 1'-0" SPACING HEIGHT NON-BEARING INTERIOR WALLS (7.5 psf LATERAL LOADS) 250S125-33 16" O.C. 12'-5" 400S125-33 16" O.C. 15'-11" DATE ISSUED: 01-08-2016 600S125-33 16" O.C. 22'-3" PROJECT NO: 2014-40156 800S125-33 16" O.C. 28'-3" SCALE: As indicated SHEET NUMBER: A600 NON-BEARING EXTERIOR WALLS (7.5 psf LATERAL LOADS) 350S162-43 16" O.C. 13'-2" 362S162-43 16" O.C. 13'-7" 400S162-43 16" O.C. 14'-4" 600S162-43 16" O.C. 19'-0" 800S162-43 16" O.C. 21'-5" WITH WEB STIFF EA. END NOTE: AT CURVED WALLS USE (2) LAYERS OF 1/2" GYP. BD. 8" B HEADER AT STOREFRONT TRACK ELECTRICAL & FIRE EXTINGUISHER CABINET SHALL HAVE THE SAME FIRE RATING AS THE WALL METAL STUDS PER WALL TYPE 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 CLG. PER PLAN NO UNUSED KNOCKOUTS OR OTHER HOLES LEFT OPEN 5/8" GLASS-MAT GYPSUM SHEATHING, SEE SPECS REVISIONS: Sim NON-BEARING EXTERIOR WALLS (7.5 psf LATERAL LOADS) UNFACED INSULATION ALL AROUND OPN'G FULL HEIGHT 4 A600 PROVIDE FIRE AND DRAFT STOPS AS REQUIRED PER 2010 C.B.C SECTION 717 SECTION OPN'G WIDTH DR L2x2 ANGLE CLIP (CLIP GAUGE TO MATCH STUD GAUGE NON-BEARING INTERIOR WALLS (7.5 psf LATERAL LOADS) SIZE 600T125-33 MTL TRACKMTL TRACK GAGE TO MATCH STUDS #10 SMS @ 16" OC EACH SIDE MTL TRACK FLANGE = 1.25" MIN. FOR ALL SILLS AND HEADERS AT OPNG WIDTHS 4'-0" TO 12'-0" MAX AT OPNG WIDTHS 4'-0" & LESS SEE WALL TYPE DETAILS FOR RATED WALL TYPE CONSTRUCTION DETAILS. SEE PLANS FOR RATING REQUIRED. STUD 600S162-54 STUDS #10 SMS @ 16" OC EACH STUD SS 6" (2) #10 SMS EACH STUD TYP EXTERIOR SIDE FLS DIM. PT. ON PLAN U.N.O. WALL SIZE TYP TRACK SIM 4' OPNG 03-116477 A# DATE STUD SIZE OVERALL STUD 3 AC OVERALL THICKNESS D OWNER: (SIM) 1.1/4" EMBED B 10" WALL TYPE PER PLAN SECTION A 11 WALL TYPE SYMBOL LEGEND 8" 1. PROVIDE ADDITIONAL WALL BRACING AND / OR BRIDGING AS MAY BE REQUIRED FOR HEIGHT OF WALL. SHEET TITLE: WALL DETAILS & FIRESTOP 2. ALL SHAFT WALLS SHALL BE FULL HEIGHT UNLESS NOTED OTHERWISE. 7/8" EXTERIOR CEMENT PLASTER O/ METAL LATH & TYVEK WRAP 4 #10 SCREWS CONNECTING TOP TRACK TYP TOP TRACK 6. ALL FIRE RATED WALLS SHALL TERMINATE AT STRUCTURE ABOVE UNLESS NOTED OTHERWISE. ALL FIRE RATED WALLS SHALL COMPLY WITH CBC CHAPTER 7 METAL STUD, PER PLAN METAL STUDS PER WALL TYPE 7. REFER TO SPECIFICATION DIVISIONS AND A-600 AND A-601 FOR HVAC, PLUMBING, AND ELECTRICAL PENETRATION OF WALLS. THERMAL BATT INSULATION GYPSUM WALL BOARD 8. 2 1/2" X 14 GA. STUDS TO HAVE 1 3/8" FLANGE. "J" MOULD WITH WEEP HOLES HILTI PUTTY PAD OR EQUAL WRAPPED OVER OUTLET 3/8" DIA. HILTI KB-TZ WITH 4" EMBED. AT EACH END AND AT 16" O.C. MAX. 9. ALL STUD GAUGE AND SPACING TO BE MAINTAINED OR ADJUSTED TO MANUFACTURER'S DESIGN CRITERIA WHICHEVER IS MORE RESTRICTIVE. ALL LIMITING HEIGHTS ARE BASED ON SSMA (STEEL STUD MANUFACTURERS ASSOCIATION) SYSTEM. THE ALLOWABLE DEFLECTION FOR STUD WALLS SHALL BE: PIPING ISOLATOR OF MINIMUM 1/2" THICK FELT OR 1" THICK PIPING INSULATION JACKET PUTTY PAD TESTED IN ACCORDANCE WITH UL 263 AND CLASSIFIED FOR UP TO 2-HOUR WALL OPENING PROTECTIVE MATERIAL FOR USE WITH BOTH METALLIC AND NONMETALLIC OUTLET OR SWITCH BOXES. CONC. CURB 6" 2" MIN. TO PAVING WHERE OCCURS TOP TRACK 3. FOR FULL HEIGHT WALLS SEE DET. 2 4. EXTEND ALL OTHER WALLS 6" ABOVE FIN. CEILING U.N.O., SEE DET. 3 EXTERIOR GLASS-MAT SHEATHING, SEE SPECS TRIM FLANGE OF ONE TRACK AND EXTEND WEB TOP LAP AT CORNER TOP TRACK 4" MIN. TO EARTH WHERE OCCURS 8 -6" SEE ELEVATION 5/16" DIA. TAPCON SCREWS AT 16" O.C. INSTALL PER ICC# ESR 2202 (1 1/2" EMBED) HSS PER PLAN 1/4" CAP PLATE B SLOTTED TOP TRACK UES REPORT #283 DET. A 800S162-43 TYP CEILING PER ARCH 1 6" MAX. 6" MIN. 8" MAX. 6" MIN. (E) COL D 4" MIN. FIRE SEALANT @ FIRE-RATED WALLS ACOUSTICAL SEALANT @ NON-RATED WALLS 18 GA TRACK w/ #10 SMS TO EACH LEG, EACH STUD, TYP BEAM TO COLUMN 1 6" 1 1/2" 6" 1/4 1/4 3 SIDES 1/4 TYP. RIO HONDO COLLEGE 1 1/2" TYP. EXISTING CONCRETE DECK 3600 Workman Mill Rd, Whittier, CA 90601 HSS PER PLAN STEEL ANGLE L4 X 4 X 1/4 x 7" WIDE 1/2" 1/2" (E) CONCRETE FLOOR OR ROOF STRUCTURE CEILING HEIGHT WHERE OCCURS 1 1/2" 6" 1 1 3/8" PLATE, 8" WIDE T&B 4" 6" 1 1/2" HSS PER PLAN DECK CLIENT ADDRESS: 16 GA CLIP ANGLE w/ (3) # 10 SMS EA LEG Sim BOOKSTORE AND PRINT SHOP 25 A600 TYP. 4 A600 Sim PROJECT NAME: 362S137-33 BRACE @ 4'-0" OC (MAX BRACE LENGTH = 10'-0") CENTER OVER STUD BELOW POST PER PLAN HSS PER PLAN L/360 - FOR EXTERNAL WALLS L/360 - FOR INTERIOR WALLS WITH STONE, TILE OR WOOD PANEL FINISH AND FOR SHAFT WALLS. L/240 - ALL OTHER INTERIOR WALLS. ADJUSTABLE RING HANGER WITH FELT LINING CONTRACTOR USING AN APPROVED EQUAL PRODUCT MUST SUBMIT FOR ARCHITECTS REVIEW A WALL TYPE SHEET. THIS SUBMITTAL TO INDICATE PROPER STUD GAUGE ND SPACING PER THE SPAN CAPACITY OF THE SUBSTITUTED PRODUCT. AT NO TIME SHOULD THE STUD GAUGE OR SPACING BE LESS THAN WHAT IS SHOWN ON HIS SHEET. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS FOR SPECIFIC FURRED OUT WALLS PER PLAN AND DETAILS. 10. REFER TO BUILDING PLANS FOR EACH BUILDING FOR LOCATION OF RATED WALLS AND REFER TO THIS SHEET FOR HEAD OF WALL CONDITION OF ALL RATED WALLS. 11. AT TILED WALLS, STOP TILE AND BACKER BOARD AT CEILING, PROVIDE 5/8" TYPE "X" GYP. BD. FOR REMAINING HEIGHT OF WALL. TOP TRACK AT CORNER 1" = 1'-0" 26 EXTERIOR WALL AT BOTTOM 3" = 1'-0" 20 PUTTY PAD 1 1/2" = 1'-0" 15 SUSPENDED PIPE HANGER 3" = 1'-0" 10 WALL TYPE GENERAL NOTES 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 8'-0" MAX 1-1/2"x1-1/2"x12GAx1" CLIP ANGLE W/ (2) #10x1-1/4" SMS 2. MAIN RUNNERS ARE 1 1/2" H.R. CHANNELS, 1.12#/FT MINIMUM 3. CROSS-FURRING MAY BE 7/8", 25 GAGE GALVANIZED HAT SECTIONS @ 24" MAX. O.C. #12 GA HANGER WIRE SEE DET. 13/A610 FOR ATTACHEMENT 4. HANGERS SHOULD BE SADDLE-TIED AROUND MAIN RUNNERS TO DEVELOP THE FULL STRENGTH OF THE HANGERS. CONT. RUNNERS (SPLICE ALL JOINTS) 5/8" MAX. 5/8" MAX. 5. CROSS-FURRING SHOULD BE SADDLE-TIED TO THE MAIN RUNNER WITH ONE STRANGE OF NO. 16 OR TWO STRANDS OF NO. 18 GAGE TIE WIRE. 6. MAIN RUNNERS SHOULD BE SPLICED BY LAPPING AND INTERLOCKING FLANGES 12" MIN. AND TYING NEAR EACH END WITH DOUBLE LOOPS OF NO. 16 GAGE WIRE. 45. 0 0° 600S137-54 SPAN (2) WALL STUDS MINIMUM USING (4) #10 x 1-1/4" SMS AT EA STUD, (ONLY (2) #10 SMS REQUIRED WHERE CLIP ATTACHES DIRECTLY TO WALL STUD) 1/2" MAX 1/2" MIN TYP (SEE NOTE 1 BELOW) TYP. HANGER WIRES @ 4'-0" O.C. 1 LAYER OF GYP. BD., MAX. 0° TO 45° TYP (SEE NOTE 1 BELOW) 7. CROSS-FURRING SHOULD BE SPLICED BY LAPPING AND INTERLOCKING THE PIECES 8" MIN. AND TYING NEAR EACH END WITH DOUBLE LOOPS OF NO. 16 GAGE WIRE. STEEL POP RIVET STEEL POP RIVET @ 4'-0" OC MAX CEILING CLIP - 12GA X 3/4" WIDE MIN. CROSS RUNNER 1"x 2" x 25 GA. MIN. CONTINUOUS ANGLE WITH (1) #10 SMS INTO 20 GA. MIN. WALL STUD @ 24" O.C. 1" 2" BRACING WIRE W/ MIN. OF 4 TIGHT TURNS IN 1-1/2" HANGER WIRE W/ MIN. OF 3 TIGHT TURNS IN 1 1/2" NOTES: 1. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. BRACING WIRE CONNECTION TO STUD 23 3" = 1'-0" WIRES @ CONC. DECK 18 4" (WHICHEVER IS LESS) 13 SEISMIC SEPARATION JOINT DETAIL 8 3" = 1'-0" #6 S.T.S.M.S. @ 12" O.C. 5" 1. Heavy Duty Main (7501) and Cross Runners required per A802. 2. BERC-2 clips required per 4PSF rating and Seismic Design Category D, E and F. 3. Anchors to be submitted. 4. Trim at OHSC to be installed 1" from vertical suports and piping. 17 A610 #12 GA VERTICAL HANGER WIRE @ 4'-0" CRIMP TOP OF TUBING FLAT & ATTACH WITH (2) 3/8" DIA. KBTZ WITH 3" EMB. (ICC-ESR-1917) SECURE SPLICE SECTIONS TOGETHER WITH (2) #8 X 1" SELF TAPPING SHT. MTL. SCREWS (S.T.S.M.S.) 6" 1' - 0" MAIN RUNNER- POP RIVET TO PERIMETER ANGLE AT STARTER WALL ONLY; COLOR TO MATCH GRID OVERLAP LAY-IN CEILING PANEL COMPRESSION STRUT. PER ICC REPORT SEE NOTE 23 5'-0" MIN. DISTANCE 6'-0" MAXI. DISTANCE 4" 12 GA.HANGER WIRE, SEE NOTES #1, 2 & 16 CEILING NOTES (SUSPENDED GYP. BD) CEILING DETAILS COMPLYING WITH ESR 1308 MAY BE SUBSTITUTED IF APPLICABLE 4" COMPRESSION POST SEE SCHEDULE AND DETAIL SLOTTED ANGLE "V" STRUT SPACER W/ HORIZ. 6d RING SHANK NAIL THROUGH SLOTS @ RUNNER WHERE OCCURS SEE NOTE #7 8" OR 1/4 OF LENGTH 3" = 1'-0" C SHAPED METAL STUDS FACE OF WALL 3/4" 8. LIGHT FIXTURES AND HVAC DIFFUSERS SHALL HAVE SUPPLEMENTARY Sim SUPPORTS AS REQUIRED, SEE DETAIL 6 CEILING CLIP NOTE: PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. 3" = 1'-0" 1" CLEAR A610 ATTACHED JOINT CEILING PERIMETER AT EXIT CORRIDOR STEEL POP RIVET COVER PLATE WITH 1" FLEXIBILITY MINIMUM IN ALL DIRECTIONS #12 GA VERTICAL HANGER WIRE @ 4'-0" MAIN RUNNER 2" WALL ANGLE SECURED TO WALL STRUCTURE W/ (2) #10 S.M.S. DRYWALL SCREWS @ 16" O.C. CEILING PERIMETER AT FREE WALL 22 3" = 1'-0" 17 SEE DSA IR 25-5 FOR ALL APPLICABLE REQUIREMENTS. 1. #12 GA. (MIN.) HANGER WIRES SHALL BE 0.106 INCHES IN DIAMETER CONFORMING TO ASTM A641. #12 GAGE WIRE SHALL BE SOFT ANNEALED, GALVANIZED STEEL WIRE WITH CLASS 1 COATING. 45° TYP. ATTACH STUD W/ (3) #10 SMS 2. #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X 4'-0" GRID SPACING AND SHALL BE ATTACHED TO MAIN RUNNERS. 1 1/2" MAX 3. PROVIDE 12 GA. HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN 8" FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF THE END TEE, WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. MAIN RUNNER 2 MA" X HANGING STUD CONNECTION 3" = 1'-0" 12 CEILING SPAY WIRE BRACING DETAIL 1' - 0" MAX. EXISTING CONC. BEAM ACOUSTICAL TILE IN SUSPENDED 'T' BAR CEILING SYSTEM - FOR DETAIL SEE DETAILS 5 & 6 SHEET A/610 7/8" METAL FURRING CHANNEL A# 7. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A 16 GA WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 12" OR LESS, THIS INTERLOCK IS NOT REQUIRED. 03-116477 AC FLS SS DATE REVISIONS: 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 11. THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT. SPLICES IN WIRES ARE NOT PERMITTED WITHOUT SPECIAL DSA APPROVAL. 12. COMPRESSION STRUTS SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB. 13. SUSPENDED ACOUSICTAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET OR LESS, AND FIRE RATED SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 96 SQUARE FEET OR LESS, SURROUNDED BY WALLS WHICH CONNECT DIRECTLY TO THE STRUCTURE ABOVE OR WALLS INDEPENDENTLY BRACED ABOVE CEILING TO STRUCTURE ABOVE, DO NOT REQUIRE BRACING ASSEMBLIES WHEN ATTACHED TO TWO ADJACENT WALLS. LIGHT FIXTURE W/ (2) 12GA. HANGER WIRES @ ALTERNATE CORNERS TO THE STRUCTURE ABOVE. 14. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET A SEISMIC SEPARATION JOINT SHALL BE PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQUARE FEET. SEE DET. 8/A610 PROVIDE ATTACHMENTS EA SIDE OF FIXTURE TO CEILING GRID (SEE NOTE 19) 15. PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIRED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER TO ALLOW FREE MOVEMENT OF (1) INCH IN ALL HORIZONTAL DIRECTIONS. CEILING SUSPENSION GRID ALIGN 6. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2 INCHES. 10. THE SPACING OF THE BRACING ASSEMBLIES SHALL BE AT 12'-0" X 12'-0" ON CENTER (PER DSA REQUIREMENTS FOR SCHOOL BUILDINGS PER IR 25-5). PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN 6'-0" FROM EACH PERIMETER WALL AND AT THE EDGE OF VERTICAL CEILING OFFSETS. THE MAXIMUM SLENDERNESS RATIO (kL/R) OF THE COMPRESSION STRUT IS 200 OR LESS. AIR DIFFUSER INTERIOR IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 9. PROVIDE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUCT AND FOUR (4) #12 GA. SPLAYED BRACING WIRES ORIENTED 90° FROM EACH OTHER. DUCT WORK ABOVE CEILING. DO NOT ATTACH TO CEILING OR CEILING TO DUCTWORK. WALL BEYOND 5. CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER CBC SECTION 1616A.1.20. CEILING GRID MEMBERS SHALL BE AT LEAST 3/4" CLEAR OF OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID MEMBERS, ONE END OF MAIN AND CROSS RUNNERS SHALL BE FREE, AND A MINIMUM OF 3/4" CLEAR OF WALL. 8. EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. AIR DIFFUSER W/ (2) 12 GA HANGER WIRES @ ALTERNATE CORNERS TO THE STRUCTURE ABOVE. 1 1/2" COLD-ROLLED STEEL CHANNEL AROUND OPENING ACCESS DOOR - SIZE & TYPE PER PLAN 7 1 1/2" = 1'-0" #12 GA VERTICAL HANGER WIRE @ 4'0" O.C. CONNECTION TO STRUCTURE PER DETAIL 13 A610 WIRE HANGER AND BRACING JAN. 31, 2017 4. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO TYPICAL HANGER SPACING. PROVIDE ADDITIONAL HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. CROSS RUNNER NOTES: 1. COMPRESSION STRUTS SHALL NOT REPLACE HANGER WIRES. 2. CEILING NOT SHOWN FOR CLARITY COMPRESSION STRUT DETAIL @ ACT SUSPENDED LAY-IN CEILING NOTES: (FOR CEILING SYSTEMS WHOSE TOTAL WEIGHT, INCLUDING AIR CONDITIONING/HEATING GRILLS AND LIGHT FIXTURES, DOES NOT EXCEED 4 PSF) LATERAL FORCING BRACING #12 GA WIRE SECURED TO MAIN RUNNER PER NOTES #6 & 7 AND CONNECTION TO STRUCTURE PER DETAIL 13 A610 12 GA X 2" X 4" X 0'-10" BENT PLATE WITH (3) 3/16" TAPCON SCREWS INSTALL PER ICC#ESR-2202 (1 1/2" EMBED) 3. USE DOUBLE 1 5/8" x 25 GA METAL STUDS FOR MAX. LENGTH UP TO 14'-4" (l/r = 192) (l/0.894 = 192) MAIN RUNNER 3" = 1'-0" 1/4" MACHINE BOLT FOR TUBING & METAL STUD: 1. USE USG DONN VSA PER ICC-ESR-1222 TABLE 2 OR SEE NOTE 23 FOR ALTERNATE MANUFACTURER 2. USE 1 5/8" x 25 GA METAL STUDS FOR MAXIMUM LENGTH UP TO 7'-2" (l/r = 192) (l/0.447 = 192) CRIMP BOTTOM FLAT AND ATTACH TO MAIN RUNNER WITH 1/4" DIAM. MACHINE BOLT CEILING DETAILS COMPLYING WITH ESR 1308 COMPRESSION POST TABLE 3600 Workman Mill Rd, Whittier, CA 90601 METAL STUD WALL AS SCHEDULED 8" MAX. CLIENT ADDRESS: HANGER AT 4'-0" O.C. EA. WAY AT MAIN RUNNER 1. VERTICAL HANGER WIRES ARE NO. 8 GAGE AND GALVANIZED. HOWEVER, IF CEILING IS NON-ACCESSIBLE, A NO. 12 GAGE WIRE MAY BE USED. 8" MAX. BOOKSTORE AND PRINT SHOP (E) CONCRETE DECK PROJECT NAME: STRUT AND (4) BRACE WIRES PER 2.35, SPACING PER 2.31 TYP. HANGER WIRE @ 4'-0" O.C. RIO HONDO COLLEGE 8" MAX TYP (SEE NOTE 1 BELOW) SUSPENDED GYPSUM BOARD CEILING SYSTEM PER CBC CHAPTER 25, CBC TABLE 25A-A AND DIVISION OF THE STATE ARCHITECT IR 25-2-13 HILTI X-CC27 U27 CEILING CLIP ASSEMBLY PER ICCESR-2184 OWNER: FROM ATTACHED JOINT EXTERIOR DATE ISSUED: 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated 17. SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. SHEET NUMBER: A610 18. WHEN DRILL-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 MUST BE FIELD TESTED FOR 200 POUNDS OF TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT OF 2 MUST BE FIELD TESTED FOR 440 LBS. OF TENSION. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. SHEET TITLE: 16. FASTEN #12 HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS. FASTEN #12 BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2 INCHES. HANGER OR BRACING WIRE ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. GYPSUM BOARD, TYP NOTE: WIRE TURNS MADE BY MACHINE WHERE BOTH STRANDS HAVE BEEN DEFORMED OR BENT IN WRAPPING CAN WAIVE THE 1-1/2" REQUIREMENT, BUT THE NUMBER OF TURNS SHOULD BE MAINTAINED, AND BE AS TIGHT AS POSSIBLE. ATTIC ACCESS PANEL, TYP. 1 1/2" = 1'-0" CEILING AT STOREFRONT HEAD 21 4" (E) CONC. DECK 12 GA.HANGER WIRE A610 2" MIN. EXISTING CONC. BEAM MAIN RUNNER- POP RIVET TO PERIMETER ANGLE AT STARTER WALL ONLY; COLOR TO MATCH GRID 4" X 16" GA. AT 24" O.C. METAL STUD 1 CONNECTION PER WINDOW MANUF. MINIMUM 1/4" DIA. SMS AT EACH END AND @ 24" O.C. 20 12" MAX. MIN. 4" X 16" GA. CALV. METAL TRACK (UNPUNCHED) USE 1 # 6 SHEET 6" 2" WALL ANGLE SECURED TO WALL STRUCTURE W/ (2) #10 S.M.S. DRYWALL SCREWS @ 16" O.C. 3" = 1'-0" WALL BEYOND 6" X 18 Go. GALV METAL STUD DIAGONAL SEISMIC BRACING @ 4' 0 O.C. W/ 4 X 12 SMS SLOTTED ANGLE "V" STRUT SPACER W/ HORIZ. 6d RING SHANK NAIL THROUGH SLOTS @ RUNNER WHERE OCCURS SEE NOTE #7 PROVIDE COMPRESSION POST AND (4) #12 GA SPLAYED BRACING WIRES @ MAX 12'-0" O.C. ON MAIN RUNNERS AND 6'-0" MAX FROM WALL. Sim 22 5/8" GYP. BD. 9'-0" CEILING AT STOREFRONT HEAD 1 1" = 1'-0" 15 1' - 0" 6" X 18 Go. GALV METAL STUD DIAGONAL SEISMIC BRACING @ 4' - 0 O.C. W/ 4 X 12 SMS AT EACH ATTACHMENT 4" X 16" GA. CALV. METAL TRACK (UNPUNCHED) USE 1 # 6 SHEET CLG HEIGHT Sim SEE NOTES 19 & 20 FOR FIXTURE SUPPORTS "V" STRUT PANEL SUSPENSION GRID (SEE NOTE 23) 5/8" GYP. BD. 22 Sim OPPOSITE FREE WALLS. align w/ mullion 1" = 1'-0" 10 ALL FLUSH OR RECESSED LIGHT FIXTURES WEIGHING 56 LBS. OR MORE AND MECHANICAL TERMINALS AND SERVICES, WEIGHING 20 LBS. ORE MORE, MUST BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4) TAUT #12 GA. WIRES EACH ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE. THESE WIRES, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE, MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT. CEILING PLAN DETAIL, TYP.1 21. SUPPORT SURFACE-MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE DEVICES WHICH SURROUND THE CIELING RUNNER AND WHICH ARE SUPPORTED FROM THE STRUCTURE ABOVE BY A #12 GAGE WIRE. SPRING CLIPS OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE 8 FT OR LONGER. MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FT. 23. THE CEILING GRID SYSTEM MUST BE RATED AS HEAVY DUTY AS DEFINED BY ASTM C635. MANUF. ARMSTRONG 1308 CERTAINTEED 3336 CHICAGO METALLIC USG A610 CEILING AT STOREFRONT HEAD 2 20. FLUSH OR RECESSED LIGHT FIXTURES, WEIGHT LESS THAN 56 LBS, AND MECHANICAL TERMINALS AND SERVICES WIEGHT LESS THAN 20 LBS., MAY BE SUPPORTED DIRECTLY ON THE RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST HAVE A MINIMUM OF TWO (2) #12 GA. SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE ABOVE. ALL 4'-0" X 4'-0" LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH CORNER. 22. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF SUPPORTING TWO (2) TIMES THE WEIGHT OF THE FIXTURE. A BRACING ASSEMBLY IS REQUIRED WHERE THE PENDANT HANGER PENETRATES THE CEILING. SPECIAL DETAILS ARE REQUIRED TO ATTACH THE PENDANT HANGER TO THE BRACING ASSEMBLY TO TRANSMIT HORIZONTAL FORCE. IF THE PENDANT MOUNTED LIGHT FIXTURE IS DIRECTLY AND INDEPENDENTLY BRACED BELOW THE CEILING, I.E. AIRCRAFT CABLES TO WALLS, THEN BRACE ASSEMBLY IS NOT REUIRED ABOVE THE CEILING. SEE IR 16-9 FOR ADDITIONAL REQUIREMENTS FOR PENDANT MOUNTED FIXTURES. LAY-IN PANEL, SEE FINISH SCHEDULE FOR TYPE. WALL BEYOND 19. ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. SCREWS OR APPROVED FASTENERS ARE REQUIRED (USE TWO #8 SELF-TAPPING TEK SCREWS AT EACH END, OR APPROVED EQUAL). SUSPENDED CEILINGS A610 A610 1 4" EXISTING EXTERIOR WINDOW 22 12" MAX. ROLLER SHADE HOUSING @ EA. WINDOW AS SPECIFIED LAY-IN CEILING PANEL 1/4" GAP W/ 1 HR. RATED SEALANT 5 1/2" MIN. 5/8" GYP. BD. 4" X 16 Ga. GALV. METAL STUD @ 24" O.C. SECURE STUD TO CONCRETE W/ (2) 3/8" DIA. HILTI KBTZ ICC-ESR-1917 6" 2.5" X 16 Ga. GALV. METAL STUD @ 24" O.C. SECURE STUD TO W/ (2) 3/8" DIA. HILTI KBTZ - ICC-ESR-1917 (WHICHEVER IS LESS) 7'-0" HEIGHT EXISTING CONC. BEAM PERIMETER STARTER WALLS (SEE NOTE 5) PROVIDE VERTICAL HANGER WIRES @ 48" O.C. ON MAIN RUNNERS 2" MIN. 8" OR 1/4 OF LENGTH CEILING AT RATED WALL Sim ATTACH STUD W/ (3) #10 SMS RATED WALL PER PLAN SEE DET. 17 A600 10'-0" HEIGHT 6 1 1/2" = 1'-0" NOTE: DRILLED-IN OR SHOT-IN ANCHORS REQUIRE SPECIAL DSA APPROVAL PRIOR TO USE IN PRESTRESSED CONCRETE. 22 12 GA X 2" X 4" X 0'-10" BENT PLATE WITH (3) 3/16" TAPCON SCREWS INSTALL PER ICC#ESR-2202 (1 1/2" EMBED) 6" X 18 Go. GALV METAL STUD DIAGONAL SEISMIC BRACING @ 4' - 0 O.C. W/ 4 X 12SHEET METAL SCREWS 3/4" CEILING FIXTURE BRACING DETAIL 4" X 4" X 1/8" ANGLE W/ (2) 3/8" DIA. HILTI KB-TZ W/ 3" EMBED. TOP OF WALL @ CONC. DECK CONNECTION PER DET. 4 / A600 (NO SLOTTED TOP TRACK) FACE OF WALL 11 4" 3 1/2" 25 A600 Sim 1" = 1'-0" 1 1/2" = 1'-0" 5 CLASSIFICATION HEAVY DUTY (HD) MAIN RUNNER PRELUDE 15/16" (7301) CROSS RUNNER XL7340/XL7328 ICC-ESR-1289 & HEAVY DUTY (HD) 15/16" CLASSIC (CS1212-20) CS2-12-12/CS4-12-12 ICC-ESR- 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 HEAVY DUTY (HD) 15/16" SEISMIC 1200 (200.01H) 1210.01H/1202.01H ICC-ES-2631 HEAVY DUTY (HD) DX (DX26) DX (DX216/DX424) ICC-ESR-1222 CEILING NOTES (LAY-IN PANEL) SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. EXISTING BEAM ABOVE DOOR SCHEDULE 1/4" THK. TEMPERED CLEAR GLASS, OCLOR AS SELECTED BY ARCHITECT N1B N1C N1E N05 N06 N07 N10 N11 N12A N12B N12C N13 N14 800S162-43 MTL. STUD AT 16" O.C. 7/8" STUCCO R-19 THERMAL BATT INSULATION 800T150-33 2 1/4" X 4 1/2" ALUMINUM STOREFRONT WINDOW SILL SHIM ALUMINUM THRESHOLD SEALANT 1/2" MAX. 1/4" MAX. EXTERIOR STOREFRONT - SILL 24 6' - 10" 6' - 11" 6' - 11" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0" 4' - 4" 7' - 0" 7' - 0" F1 F1 F2 A A B C B A D E A A DOOR FRAME FIRE RATING MATERIAL FINISH MATERIAL FINISH HEAD DETAIL - AL AL AL HM HM HM HM HM HM HM AL HM HM 20 MIN. 20 MIN. 20 MIN. 20 MIN. AN AN AN FLFD FLFD FLFD FLFD FLFD FLFD FLFD AN HM HM AL AL AL HM HM HM HM HM HM HM AL HM HM AN AN AN FLFD FLFD FLFD FLFD FLFD FLFD FLFD AN FLFD FLFD DET. 18/A650 DET. 18/A650 DET. 18/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 21/A650 DET. 22/A650 DET. 22/A650 THRESHOLD DET. 24/A650 DET. 24/A650 DET. 24/A650 DET. 10.B/A650 DET. 10.B/A650 DET. 10.B/A650 DET. 10.A/A650 DET. 10.A/A650 DET. 10.A/A650 DET. 10.A/A650 DET. 15/A650 DET. 10.A/A650 DET. 10.A/A650 HARDWARE SET 02 02 03 04 04 07 08 10 06 05R 09 11 11 REMARKS CARD READER CARD READER 1/2" CDX PLYWOOD CONNECTION PER WINDOW MANUF. (2) 1/4" DIA. TITEN HD EA. SIDE 1 WITH 3 3/4" EMBED. TORQUE AT 651B-TR STOREFRONT HEAD 2 3" = 1'-0" DET. 14/A650 DET. 14/A650 DET. 14/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 22/A650 DET. 20/A650 DET. 22/A650 DET. 22/A650 DETAILS JAMB EXISTING DOOR SCHEDULE CONNECTION PER WINDOW MANUF. MINIMUM (1) 3/8" DIA. HILTI KBTZ (ICC-ESR-1917) AT EACH END AND @ 24" O.C. 3" = 1'-0" 6' - 0" 6' - 0" 3' - 0" 3' - 0" 3' - 0" 6' - 0" 6' - 0" 6' - 0" 3' - 5 3/8" 3' - 0" 6' - 0" 3' - 0" 3' - 0" TYPE CONT. SEALANT SHIM STOREFRONT DOOR THRESHOLD HSS PER PLAN CEILING, WHERE OCCURS 2" CARPET BEVELED 2:1, TYP. 2-12 (1) LAYER 5/8" TYPE "X" GYP. BD. 6" 10" 10" TOE KICK ALUMINUM STOREFRONT 1/8 HEIGHT 3" = 1'-0" WTWT E1 E2 E3 E4 14 WIDTH 3' - 0" 3' - 10" 5' - 11 1/2" 6' - 0" HEIGHT 7' - 0" 7' - 0" 7' - 0" 6' - 10" TYPE A F2 B F1 DOOR FRAME FIRE RATING MATERIAL FINISH MATERIAL FINISH HEAD DETAIL - HM AL HM AL DETAILS JAMB HARDWARE SET THRESHOLD HM AL HM AL REMARKS 01R 01R 12 13 RIO HONDO COLLEGE 1/4" THK. TEMPERED CLEAR GLASS, OCLOR AS SELECTED BY ARCHITECT SLOTTED TOP TRACK UES REPORT #283 WIDTH ALARMED ALARMED NEW HARDWARE NEW HARDWARE AND PANIC HARDWARE SEE SPEC SECTION 08 71 00 FOR DOORS HARDWARE GRID 4 1/2" 1/2" 2" SHIM STOREFRONT JAMB 1/4" THK. TEMPERED CLEAR GLASS COLOR AS SELECTED BY ARCHITECT WALL PER PLAN 2" CONNECTION PER WINDOW MANUF. MINIMUM (1) 3/8" DIA. HILTI KBTZ (ICC-ESR-1917) AT EACH END AND @ 24" O.C. 2" X 4 1/2" ALUMINUM STOREFRONT WINDOW INTERMEDIATE CORNER BEAD GLASS PER ELEVATION 7" BUTT JOINT FLEXIBLE SEALANT & BACKER ROD EA. SIDE STOREFRONT MULLIONS / INTERMEDIATE 3" = 1'-0" STOREFRONT JAMB 23 3" = 1'-0" ALUMINUM WINDOW HEAD/JAMB - INT. FIXED WINDOW 18 13 ALUMINUM WINDOW FRAME VERTICAL MULLION BEYOND 3/4" SOLID WOOD TRIM W/ ROUNDED EDGES SEE SPEC 1 DOUBLE METAL STUDS AT JAMB. BOX HEADER AT DOOR HEAD 1 15/16" MIN. 3" = 1'-0" GLAZING WALL TYPE PER PLAN HORIZONTAL MULLION HOLLOW METAL FRAME 5/8" 2" 1 INTERIOR INTERIOR INTERIOR STOREFRONT FRAME STARTER SEAL DOOR OPENING OWNER: CONNECTION PER WINDOW MANUF. MINIMUM 1/4" DIA. SMS AT EACH END AND @ 24" O.C. HORIZONTAL MULLION BEYOND SNAP IN STEEL ANCHOR, MIN. OF 3 PER JAMB JAN. 31, 2017 CONNECTION PER WINDOW MANUF. MINIMUM 1/4" DIA. SMS AT EACH END AND @ 24" O.C. IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES FINISH PER FINISH SCHEDULE FINISH PER FINISH SCHEDULE 2 3/8" VARIES AC 1 15/16" 3/8" TITEN HD @ 24" O.C. W/ 4" EMBED, ICC ESR-2713 SILL - INT. FIXED WINDOW 17 CORRIDOR 14 A650 SHIM AS REQUIRED ATTACH WITH (2) #12 SHEET METAL SCREWS @ 12" O.C. DOORS TYPE: 6" = 1'-0" STAINLESS STEEL SLATS TYPE MARBLE THRESHOLD 1:2 SLOPE CARPET CERAMIC TILE FLOORING W1 W2 W3 1/2" MAX. DOOR WHERE OCCURS - CENTER ON TRANSITION WIDTH 5' - 0" 4' - 7" 7' - 0" HEIGHT 4' - 0" 4' - 0" 4' - 0" FIRE RATING SHEET RESILIENT 60 MIN 60 MIN - AL AL AL AN AN AN GLAZING IG IG IG 1/2" MAX. 11 A650 3 A600 HEAD @ ROLLING 3" = 1'-0" 20 Sim (3) 1/4" DIA SMS SEE DET. 8/A640 1 (PRINT SHOP PUBLIC LOBBY) 11/A650 11/A650 12/A650 11/A650 1 11/A650 13/A650 SILL DETAIL SILL @ ROLLING (INT.) W1 / W2 RATED D 3" = 1'-0" 15 12' - 4" 12' - 4" (N) NEW GLASS DOOR 1 11/A650 11/A650 12/A650 13 A650 12 A650 1 THRESHOLD DETAIL 12" = 1'-0" 10 DATE ISSUED: 01-08-2016 PROJECT NO: 2014-40156 SCALE: As indicated SHEET NUMBER: A650 TEMPERED, TYP. (E) (N) 4' - 0" (E) F2 SHEET TITLE: DOORS / WINDOWS SCHEDULES THICKNESS 1/4" THK 1/4" THK 1/4" THK TEMPERED CARPET CONCRETE A.F.F. (E) 10" 10" DETAILS HEAD JAMB 3' - 6" METAL STRIP 3' - 6" DOOR WHERE OCCURS - CENTER ON TRANSITION 1/2" MAX. DOOR GUIDES BEYOND (E) (N) 8" F1 13 A650 11 A650 CARPET 1/4" MAX. 6" X 1 1/4" X 16GA TRACK CONT. LENGTH OF CASEWORK 24 A650 E C (PRINT SHOP) TEMPERED 6' - 0" 4' - 0" 1 (E) (N) 1" 15 A650 D FRAME MATERIAL FINISH 4' - 0" BRACKET ATTACHMENT TO STUD WALL SEE DET. 15 / A640 1/4" MAX. HOOK FOR REMOVABLE CRANK HANDLE TILE CARPET JOINER DOOR WHERE OCCURS - CENTER ON TRANSITION L2X2X1/4 @ 3'-0" O.C., PROVIDE RUBBER TRIM TO COVER SHARP EDGES 34" MAX 10" STAINLESS STEEL HOOD (N) (E) TEMPERED, TYP. 2' - 6" 1" B CONTINUOUS SEALANT (N) (E) DOOR TYPES AND SCHEDULE SHEET RESILIENT 1/4" MAX. 24" WIDTH COUNTERTOP WINDOW TYPE: FASCIA PRINT SHOP PUBLIC SIDE C 11 A 2" OPENING DIMENSION 1 3/8" 1 1/4" 10" CASEWORK COUNTERTOP SEE DETAIL 15 / A640 TEMPERED (E) WINDOW SCHEDULE SHEET RESILIENT STAINLESS STL COUNTERTOP SLOPE 1/8"/12" 3" = 1'-0" B DOOR WHERE OCCURS - CENTER ON TRANSITION DOOR GUIDE BEYOND WALL PER PLAN HEAD / JAMB / SILL INT. RATED WINDOW 7'-0" HEIGHT CR 60 MINUTE RATED; CLASS II IMPACT RATED GLASS 16 21 A650 48" A.F.F. 2" MULLION AT WINDOW 21 TEMPERED (N) A 3" = 1'-0" TEMPERED 18 A650 20 A650 9" 60 MINUTE RATED FRAME - TGP DESIGNER SERIES OR EQUIVALENT ALUMINIUM FIXED WINDOW FRAME 22 A650 CARD READER (WHERE OCCURS) CONT. INTUMESCENT SEALANT BETWEEN SHIMS A JAMB @ ROLLING (INT.) 22 A650 HARDWOOD (OAK) SHIMS AT ANCHOR LOCATIONS ALUMINIUM OUTSWINGING WINDOW FRAME 2" 22 A650 SEALANT TO MATCH FRAME COLOR 3" WALL PER PLAN 22 A650 2' - 10" 2" 2" CORNER BEAD. PAINT TO MATCH WALL B (N) TEMPERED 43" MAX. ALUMINUM ANODIZED GUIDES (N) MIN. CONNECTION PER WINDOW MANUF. MINIMUM 1/4" DIA. SMS AT EACH END AND @ 24" O.C. ALUMINIUM FIXED WINDOW FRAME EXISTING STOREFRONT MIN. C COUNTERTOP BELOW 14 A650 WALL PER PLAN 2" 2" 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 Book Store ALUMINIUM FIXED WINDOW FRAME STAINLESS STEEL SLATS 4 1/8" 12 7' - 0" ALUMINIUM INSWINGING WINDOW FRAME 3" = 1'-0" 3' - 2" 3" = 1'-0" 7' - 0" STOREFRONT BASE @ INT. 22 SS REVISIONS: 43" MAX. 3" = 1'-0" FLS DATE CAULKING HOLLOW METAL DOOR FRAME @ INTERIOR 03-116477 A# WALL PER PLAN DOOR PER SCHEDULE 1 9/16" 3600 Workman Mill Rd, Whittier, CA 90601 4 1/2" WTWT CLIENT ADDRESS: 4 1/2" BOOKSTORE AND PRINT SHOP 1/2" DIA. TITEN HD @ 24" O.C. WITH 3 3/4" EMBED. TORQUE AT 651B-TR PROJECT NAME: 7" 7" W3 NON RATED WINDOW TYPES AND SCHEDULE WINDOW/DOOR CODE AND ABREVIATIONS: AL AN BZ CC CLR FC FF FLFD FP FPFP FRA FS GA GL GS IG HM HMK LVR LG MF PR SCW SMC ST SS T WG - ALUMINUM ANODIZED CLEAR ANODIZED BRONZE CONCEALED CLOSER CLEAR FLOOR CLOSER FACTORY FINISH FUSIBLE LINK FIRE DAMPER FIELD PAINT FACTORY PRIMED, FIELD PAINTED FIRE RATED ASSEMBLY FIELD STAINED GALVANIZED GLASS OR GLAZING GALVANIZED STEEL SEALED INSULATING GLASS PER SPEC HOLLOW METAL HOLLOW METAL FRAME - KNOCK DOWN LOUVER LAMINATED GLASS MILL FINISH PAIR SOLID CORE WOOD SURFACE MOUNTED CLOSER STEEL STAINLESS STEEL TEMPERED 1/4" WIRE GLASS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR-CEILINGS, & ROOF-CEILINGS SHALL BE PROTECTED AS REQUIRED IN UBC SEC. 709 & 710 3. ALL HVAC UNITS OR SYSTEMS SERVING A COMMON AIR SPACE MUST BE INTERCONNECTED TO SHUT DOWN IMMEDIATELY UPON ALARM CONDITION FROM DUCT DETECTORS WITHOUT INTERFERENCE FROM EMS OR ANY OTHER SYSTEMS. ALL CONTROL RELAYS USED FOR SHUT DOWN MUST BE CALIFORNIA STATE FIRE MARSHAL LISTED FOR RELEASING SERVICE. 4. FOR CONNECTION TO STRUCTURE & PIPE SUPPORT SEE DETAIL 5. FOR THERM0STAT MOUNTING SEE DETAIL 1,2,6 M301 3 M301 6. FOR DUCT GAUGE SEE DETAIL 7. FOR AIR DISTRIBUTION SEE DETAIL 4 M301 5 M301 8. FOR FAN COIL MOUNTING SEE DETAIL 9. FOR FAN COIL WIRING DIAGRAM & WIRING NOTES SEE DETAIL 8 M301 10. FOR DUCT DETECTOR SEE DETAIL 9 M301 11. FOR SMOKE FIRE DAMPER SEE DETAIL 12. FOR SPLIT SYSTEM WIRING DIAGRAM SEE DETAIL 11 M301 13. FOR EXHAUST FAN WIRING SEE DETAILS 12,13 M301 14. CAMPUS EMS IS ALERTON. 15. CONTRACTOR SHALL FIX LEAK IN MAIN COLD DUCT ABOVE OFFICE'S & BOOKSTORE. G PRINT SHOP PUBLIC LOBBY 12 K 20x24 LOUVER IN DOOR W/ MIN 50% FREE AREA L 20x24 LOUVER IN DOOR W/ MIN 50% FREE AREA H 18x18 CR 800 CFM 18x18 CR 800 CFM 14x14 CD 750 CFM 20"ø CWR SWS HWR HWS 14"ø 4 18x18 CR 800 CFM EF 2 EF 1 14 14"ø 16"ø 14"ø 18"ø FC 1 14x14 CD 750 CFM OWNER: 16"ø 14x14 CD 750 CFM 22"ø 14x14 CE 600 CFM 14"ø 24"ø T FC-1 14"ø 3 14"ø (E) VAV-C 10"ø 1 12"ø DD 11 8x8 CD 225 CFM 12"ø 10"ø 1 (E) 16"x12" N.I.C. (E) VAV-C 14 8x8 CD 200 CFM (E) VAV-C 12x12 CD 410 CFM STAGING 7 10"x10" 12"x10" 12x12 CR 380 CFM 10x10 CD 380 CFM 1 SFD T (E) VAV-E 14 8x8 CD 235 CFM 10"ø 8x8 CD 235 CFM (E) VAV-E OFFICE 5 12"ø (E) VAV-E 10"x10" 6x6 CD 100 CFM 8 OFFICE 6 10"ø 10x10 CD 300 CFM 14"ø (E) 28"x18" 16"ø 10"ø 12"ø 8"x8" (E) 62" x 18" RETURN DUCT 8x8 CR 225 CFM (E) VAV-F T 14 (E) VAV-H 14 6"x6" 6"ø 6"ø 6x6 CR 40 CFM (E) VAV-F (E) FC-3 10"ø 14x14 CR 570 CFM 18"ø 16"ø VAULT 4 9"ø CLERK ROOM 3 13 FC 2 6x6 CD 40 CFM 8x8 CD 225 CFM 10"ø 14x14 CR 580 CFM 10"ø INLINE MERV 8 FILTER BOX 10"ø 12"ø 2 CONNECT (N) 12"X6" SUPPLY DUCT TO (E) 12"X6" DUCT. 3 SET OSA MOTORIZED VOLUME DAMPER TO 600 CFM. 4 CONNECT (N) HWR, HWS, CWR, & CWS PIPING TO (E) HWR, HWS, CWR, & CWS PIPING RISERS. AC 5 (E) PNEUMATIC CONTROLS SHALL BE REPLACED W/ NEW DDC. DATE 6 CONNECT (N) 20"ø SUPPLY & 22"ø RETURN TO (E) FAN COIL. 7 CONNECT (N) 20"X14" SUPPLY DUCT TO (E) VAV BOX. 8 CONNECT (N) 14"X12" SUPPLY DUCT TO (E) VAV BOX. 9 CONNECT (N) 18"ø SUPPLY DUCT TO (E) VAV BOX. 10 CONNECT (N) 10"X16" SUPPLY DUCT TO (E) VAV BOX. 11 CONNECT (N) 14"ø SUPPLY DUCT TO (E) VAV BOX. 12 CONNECT (N) 12"ø SUPPLY DUCT TO (E) VAV BOX. 13 CONTRACTOR TO FIELD VERIFY ROUTE OF DX PIPING FROM FAN COIL TO HEAT PUMP ON ROOF. 14 RELOCATED (E) THERMOSTATS. 6x6 LOUVER ABOVE DOOR W/ MIN 50% FREE AREA 2 WEEKEND COLLEGE 2 FLS SS REVISIONS: 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 12"ø (E) FC-3 20"ø 16"ø 10"ø 12x12 CR 405 CFM FOLLETT BOOKSTORE 15 22"ø 12x12 CR 405 CFM 10x10 CD 300 CFM 10x10 CD 330 CFM 12"ø 10"ø 10x10 CD 330 CFM 20"ø DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 1/8" = 1'-0" SCALE: 12"ø 12"ø 12x12 CR 400 CFM 14"x14" M101 SHEET NUMBER: 17 SF A# 03-116477 1 14"ø 6 12"ø 10x10 CD 295 CFM 1 10x10 CD 290 CFM 16"ø (E) VAV BOX TO REMAIN & TO BE CAPPED FOR FUTURE USE. T 14"x14" 10"ø 1 10x10 CD 300 CFM 9 18"ø 12x12 CR 400 CFM IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 14 26"x14" 6x6 CD 100 CFM 16"ø 10x10 CD 335 CFM 16 7 8x8 CR 100 CFM 10"ø 10"ø (E) VAV-H T 8"x8" 10x10 CD 335 CFM 10x10 CD 295 CFM 10x10 CD 295 CFM (E) 22"x18" 8"x8" 10"ø 10"ø 12"ø 10x10 CD 295 CFM (E) 24"x18" 10x10 CD 335 CFM 10"ø 10x10 CD 295 CFM (E) 32"x18" N.I.C. 12"ø 12"ø 12"ø 12x12 CR 400 CFM 14x14 CR 790 CFM 10x10 CD 295 CFM 10"ø 1 8x8 CR 100 CFM 10x10 CD 335 CFM 10"ø 10 12x12 CR 380 CFM 14x14 CR 790 CFM CONSTRUCTION NOTES 15a 10x10 CD 300 CFM 10"x16" (E) MENS RR 3 Space 167 10"ø 12"ø 10x10 CD 370 CFM 12x12 CR 445 CFM 14"x14" 14x14 CR 790 CFM 10x10 CD 295 CFM 12"ø N.I.C. (E) WOMENS RR 4 12"x12" 12x12 CR 480 CFM 10x10 CD 370 CFM 14"x14" 20"ø 10x10 CD 380 CFM 1 12"x12" SFD 12"x12" 14 14"x12" JAN. - 14"x14" (E) VAV-E T 15 STORAGE 10 10x10 CD 240 CFM (E) 12"X6" EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O 1 8x8 CD 220 CFM 14x14 CD 750 CFM T (E) VAV-C 14 SFD 12"x10" 10x10 TG 700 CFM T (E) VAV-C 12"x6" 2 10x10 TG 700 CFM 16x16 CR 820 CFM 1 10x10 CD 240 CFM N.I.C. 12x12 CD 410 CFM (E) 28"x12" (E) 24"x12" N.I.C. L (E) 14"x12" No. 33209 ST N.I.C. (E) LOUNGE - ER 16"x16" FESSIONA PRO L M. J OH N N E EE R GIN N SO 8x8 CE 200 CFM ED EN 14"ø 12"ø REGIST 8"ø 20"ø 12 8"ø 22"ø (E) VAV-D IA SF 1 J V F S TE E PRINT SHOP 11 RIO HONDO COLLEGE 7 M301 3600 Workman Mill Rd, Whittier, CA 90601 2. CLIENT ADDRESS: FOR LINE TYPES, SYMBOLS & ABBREVIATIONS SEE LEGEND ON P0.1. PROJECT NAME: 1. BOOKSTORE AND PRINT SHOP GENERAL NOTES SHEET TITLE: 16x16 LOUVER ABOVE DOOR W/ MIN 50% FREE AREA 16x16 LOUVER ABOVE DOOR W/ MIN 50% FREE AREA MECHANICAL FLOOR PLAN KEY PLAN 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com MECHANICAL FLOOR PLAN 1/8" = 1'-0" 1 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 INLET SAMPLING TUBE 3/4" RACEWAY 120V (BY ELEC.) RELAY MODULE MOUNTED IN 4S BOX W/ 4S EXT. SUPPLY DUCT LONG RADIUS TURN - NO KINKS 2" WIDE x 22 ga. HANGER STRAP FOR CONNECTION TO STRUCTURE REFER TO OPTIONAL SIDE CONNECTION TO PLENUM WHERE CEILING SPACE IS LIMITED AIRFLOW 1/2" RACEWAY 120V (BY ELEC.) DISC. SW. 208V-1ø-60Hz. 1/2" RACEWAY 4S DEEP BOX CEILING DIFFUSER OR REGISTER, REFER TO SPEC'S FOR MFR.# AND MODEL # CEILING - REFER TO ARCHITECTURAL REFLECTED CEILING PLAN 1 3/8"Ø HILTI KB TZ W/ 3-1/4" MIN. EMB. (ICC-ESR 1917) UNISTRUT P1843 ANGLE CLIP 6 DUCT WIDTHS MINIMUM DISC. SW. EF 2 CEILING 3/4" RACEWAY 120V (BY ELEC.) N.O. RELAY NOTE: 1. DUCT DETECTOR MUST BE PHOTOELECTRIC TYPE 2. DUCT DETECTOR SHALL BE MOUNTED IN SUPPLY DUCT PRIOR TO ANY TRANSITIONS OR TURNS 3. DUCT DETECTOR IS SYSTEM SENSOR INNOVAIR D4120 AIR VELOCITY 100 TO 4000 FPS CSFM LISTING # 3242-1653:207 SF 1 ITEMS NOT SHOWN DASHED TO BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR INLINE DUCT SMOKE DETECTOR MOUNTED MIDWAY BOTH DIRECTIONS 13 5 CONNECTION TO STRUCTURE FOR CONNECTION TO STRUCTURE SEE DETAIL TYPICAL SQUARE OR RECTANGULAR DUCT FOR CONNECTION TO STRUCTURE SEE 1 "SYSTEM SENSOR" 2151 IN-DUCT FACTORY MOUNTED SMOKE DETECTOR CSFM # 7272-1209: 159 1 2x2x16 GA. DIAGONAL "L" BRACE PER SMACNA GUIDELINES FOR SEISMIC RESTRAINT. IF DISTANCE BELOW SUPPORTING STRUCTURAL MEMBER IS LESS THAN 12", DIAGONAL BRACE MAY BE OMITTED - G.I. DUCT HANGER - SEE SCHEDULE BELOW FOR SIZE 45 1 1 - 1 HANGER STRAP - SEE SCHEDULE BELOW 3/8"∅ MACHINE BOLT RIGID INSULATION, CANTSTRIP AND ROOFING BY ROOFING CONTRACTOR # 10 SMS (TYP.) 2 x 2 x 16 GA. G.I. DIAGONAL BRACE ALTERNATE SIDES EVERY HANGER SHEET METAL ROOF SEE ARCHITECTURAL DRAWINGS DUCT STRAP - SAME AS HANGER STRAP 1" MIN. NOTE: PER 2013 SMACNA HVAC DUCT CONSTRUCTION STANDARDS AND 2013 CMC SECTION 603 "RUSKIN" COMBINATION SMOKE/FIRE DAMPER MODEL NO. FSD60, CALIFORNIA STATE FIRE MARSHAL LISTING NO. FIRE DAMPER LISTING (3225-245:102) & SMOKE DAMPER LISTING (3230245:110) SHEET METAL SLEEVE DUCT SIZE HANGER SIZE HORIZONTAL MAX. SPACING MATERIAL DUCT SIZE HANGER STRAP SCHEDULE HANGER SIZE MAX. SPACING MATERIAL UP THRU 18" 1" x 18 GA. 10'-0" O/C G.I. STEEL UP THRU 10" 1" x 22 GA. 10'-0" O/C G.I. STEEL 19" TO 30" 1" x 18 GA. 10'-0" O/C G.I. STEEL 11" TO 20" 1" x 22 GA. 10'-0" O/C G.I. STEEL 31" TO 48" 1" x 1/8" 10'-0" O/C G.I. STEEL 21" TO 40" 1" x 20 GA. 10'-0" O/C G.I. STEEL MAX. SPACING MATERIAL DUCT SIZE MAX. SPACING MATERIAL ED FESSIONA PRO L M. J OH N N E No. 33209 EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O L (E) WALL HANGER STRAP SCHEDULE EE R GIN N SO HEAT PUMP MOUNTING - 1 HORIZONTAL NOTE: PER 2013 SMACNA HVAC DUCT CONSTRUCTION STANDARDS AND 2013 CMC SECTION 603 EN ADDITIONAL BLOCKING AS REQUIRED FOR ATTACHMENT OF ISOLATOR TO EQUIPMENT PLATFORM. CONTRACTOR TO COORDINATE EXACT LOCATIONS. EXTERNAL DAMPER ACTUATOR MOTOR (FACTORY MOUNTED) SFM NOTES: 1. FIRE DAMPER DETAIL FOR REFERENCE ONLY 2. FIRE DAMPER SHALL BE STATE FIRE MARSHAL APPROVED AND INSTALLED STRICTLY PER MANUFACTURER'S PRINTED INSTRUCTIONS. 3. MANUFACTURER'S INSTALLATION INSTRUCTIONS SHALL BE MADE AVAILABLE TO THE INSPECTION AUTHORITIES. 4. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO INSTALLATION. 5. FIRE DAMPER SHALL CONFORM TO UBC CHAPTER 7 6. FIRE DAMPER SHALL CONFORM TO NFPA 90A 7. DUCT DETECTOR SHALL BE INSTALLED WITHIN 5 FEET OF THE DAMPER WITH NO AIR OUTLETS OR INLETS BETWEEN THE DETECTOR AND THE DAMPER. 14 ST ROOF PLATFORM BY CONTRACTOR. CONNECT PLATFORM TO CONCRETE ROOF PER MANUFACTURER. USE MIN 3/8"ø HILTI KBTZ W/ 3" EMBEDMENT, STAINLESS STEEL, @ EACH CORNER & @ 24" OC MAC EACH SIDE. (ICC-ESR-1917) FOR ROUND DUCT CONN. TO SMOKE/FIRE DAMPER PROVIDE SHEET METAL BLANK-OFF PLATE ROUND DUCT SEE PLANS FOR SIZE ER "CALDYN" TYPE VT MOUNTING PAD. TYP. ( 4 ) REGIST SECURE TO EQUIPMENT PAD W/ (4) 3/8" LAG SCREWS X 4" LONG, STAINLESS STEEL (L) L1xL1x16 GA x 6" LONG, TYP, W/ (2) 3/8"ø LAG SCREW TO WOOD PLATFORM X 2" LONG NOTE: CONTRACTOR SHALL LOCATE (E) RE-BARS IN CONCRETE BEFORE DRILLING AND SHALL NOT DAMAGE (E) RE-BAR IN CONCRETE. ELECTRICAL JUNCTION BOX ACCESS DOOR EITHER SIDE - 89 LBS 2,6 - AIR DISTRIBUTION - ROUND 1 1/2'' x 1 1/2" ga. ANGLES FASTEN TO COLLAR ONLY W/ #10 SMS AT 8" 0/C RECTANGLE OR ROUND DUCT. SEE PLANS FOR SIZE AND LOCATION CONDENSING UNIT 9 HANGER & STIFFENER PER DETAILS (2 ea) 1"x3"x16 ga. SHT MTL BENT CLIP SECURED TO CD/CR WITH #10 SMS AT OPPOSITE CORNERS NOTE: SEAL ALL JOINTS & CONNECTIONS AIR TIGHT WITH APPROVED SEALANT, REFER TO SPEC'S DUCT DETECTOR - - SINGLE GANG SWITCH RING REMOTE LED/TEST (RTS151KEY) (MOUNTED FLUSH TO CEILING) CSFM LISTING #7300-1653:212 UL RATING S2522 2,6 1 GALV. PLENUM SECURE TO CD/CR WITH (4) #10 SMS (TYP) REMOTE LED (RTS151KEY) COUPLER VERTICAL SMOKE FIRE DAMPER - WALL DUCT SIZE HANGER SIZE UP THRU 24" 1" x 1/8" STRAP 12'-0" O/C G.I. STEEL UP THRU 10" 2" x 18 GA. 12'-0" O/C G.I. STEEL 25" TO 36" 1" x 1" x 1/8" ANGLE 12'-0" O/C G.I. STEEL 11" TO 20" 2" x 16 GA. 12'-0" O/C G.I. STEEL 37" TO 48" 1-1/8" x 1-1/8" x 1/8" ANGLE 12'-0" O/C G.I. STEEL 21" TO 40" 1/8" STEEL X 1-1/2" 12'-0" O/C G.I. STEEL DUCT SUPPORT - RECT. 10 6 HANGER SIZE IA EXHAUST FAN WIRING FOR CONNECTION TO STRUCTURE REFER TO FILLER PANEL CEILING UNISTRUT P1000 DIAGONAL BRACE WHERE REQUIRED SEE DETAILS RIO HONDO COLLEGE 208V-1ø-60Hz. (E) 8-1/2" MIN THICK PRETENSIONED CONCRETE ROOF / FLOOR. V 12 ga WIRE OWNER: ITEMS SHOWN DASHED TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR 3600 Workman Mill Rd, Whittier, CA 90601 CONNECT FLEX DUCT TO PLENUM COLLAR WITH (3) #10 SMS S TE 208V-1ø-60Hz. LIGHT SWITCH - SEE ELECTRICAL PLANS FOR LOCATION CLIENT ADDRESS: - PROJECT NAME: TO FAN SHUTDOWN (BY ELEC.) BOOKSTORE AND PRINT SHOP 1 EXHAUST TUBE IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES DUCT SUPPORT - ROUND 2 A# 03-116477 AC FLS SS DATE 208V-1ø-60HZ CONCRETE ROOF/FLOOR DISC. SW. REVISIONS: DISC. SW. 1 1 1 4 DISC. SW. 3/8"ø HILT KWIK BOLT TZ W/ 4" EMBEDMENT, W/ COUPLER TO THREADED ROD (ICC-ESR 1917) HP FAN COIL 4'-0" FC 2 3/8"ø THREADED HANGER ROD 2 208V-1ø-60HZ 3 2 1 T REMOTE T-STAT 1 ALL WIRING AND EQUIPMENT SHOWN DASHED SHALL BE FURNISHED AND INSTALLED BY THE ELECTICAL CONTRACTOR. 2 ALL LOW-VOLTAGE WIRING SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. 3 ALL CONDUIT FOR LOW-VOLTAGE WIRING SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 4 1 SF MAX TOP OF T-STAT TOP OF T-STAT 2x2x3/16. DIAGONAL "L" BRACE. 24 V. CONTROL INTERLOCK WIRING BY MECHANICAL CONTRACTOR DESCRIPTION DATE GENERAL REVIEW 04-01-2016 FOR CONNECTION TO STRUCTURE SEE DETAIL 1 24" - 2 BRACE 44" MAX 48" UNISTRUT SECURE ALL THREAD TO UNISTRUT W/ ABL. NUTS AND LOCKWASHERS. MOUNTING HEIGHT DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 OVER OBSTRUCTION 12" = 1'-0" SCALE: SIDE VIEW CONNECT TO THE HOT LEG OF THE SUPPLY FAN MOTOR. PLAN VIEW NOTE: CONTRACTOR SHALL LOCATE (E) RE-BARS IN CONCRETE BEFORE DRILLING AND SHALL NOT DAMAGE (E) RE-BAR IN CONCRETE. M301 SHEET NUMBER: SPLIT SYSTEM WIRING DIAGRAM 11 FAN COIL MOUNTING 7 THERMOSTAT MOUNTING RECTANGULAR DUCT SIZE 120V - 1ø - 60hz 208V - 3ø - 60hz DISCONNECT SWITCH 120V - 1ø - 60hz 1 LIGHT SWITCH - SEE ELECTRICAL PLANS FOR LOCATION ITEMS SHOWN DASHED TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR DISCONNECT SWITCH M ALL WIRING AND EQUIPMENT SHOWN DASHED SHALL BE FURNISHED AND INSTALLED BY THE ELECTICAL CONTRACTOR. 4 2 FC - 4 ITEMS NOT SHOWN DASHED TO BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR 3 EF 3 4 2 TRANSVERSE JOINT BRACING 26 DD, SS NONE 13" TO 18" 24 DD, SS NONE 19" TO 30" 24 DD, SS NONE 31" TO 42" 22 1" PS OR BS 1x1x1-1/8 43" TO 54" 22 1-1/2" STANDING SEAM 1.5x1.5 TRANSVERSE JOINT BRACING ROUND 1 DUCT MOUNTED SMOKE DETECTOR GAUGE ALL LOW-VOLTAGE WIRING SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. ALL CONDUIT FOR LOW-VOLTAGE WIRING SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. GAUGE UP TO 9" 26 2" SLIP NONE 10" TO 14" 24 4" SLIP NONE 14" TO 23" 22 4" SLIP NONE 24" TO 30" 22 4" SLIP 1x1x1-1/8 NOTE: LOW PRESSURE DUCT CONSTRUCTION: GAUGES, TRANSVERSE JOINTS, SPACING OF JOINTS AND INTERMEDIATE BRACING SHALL BE AS TABULATED ABOVE, IN WHICH TRANSVERSE JOINTS ARE SHOWN SS FOR S-STOP, DS FOR DRIVE SLIP, PS FOR POCKET SLIP, AND BS FOR BAR SLIP, PS AND BS LAPPED AND RIVETED AT CORNERS. INTERMEDIATE BRACING WHERE SHOWN MAY BE OMITTED IF DUCT SECTIONS OF FOUR FEET (4'-0") OR LESS ARE USED. MAXIMUM SPACING OF BRACING - FOUR FEET (4'-0") ALL EQUIPMENT NOT SHOWN DASHED SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR. T - SHEET TITLE: MECHANICAL DETAILS DUCT UP TO 12" DUCT SIZE DD 3 DUCT GAUGE 7 DAY PROGRAMMABLE T-STAT WITH FAN SET TO OPERATE DURING OCCUPIED HOURS 4 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com EXHAUST FAN WIRING 12 FAN COIL WIRING DIAGRAM 8 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 NUMBER FIXTURE UNIT 1/2" 1 0 1.5 2.5 6 WC 5 30 3/4" 5 0 5 3.2 5 L 1 5 1" 13 0 10 4.0 2 S 1.5 3 1-1/4" 24 0 17 4.5 2 DF .5 1 1-1/2" 47 10 27 5.0 1 (E) F.U. 11 11 64 158 2" 56 6.0 2-1/2" 380 245 100 7.5 3" 691 630 160 8.0 4" 1171 1171 230 8.0 3. TOTAL TOTAL FIXTURE UNITS 50 TOTAL G.P.M. 50 BEFORE PROCEEDING WITH THE WORK THIS CONTRACTOR SHALL CAREFULLY CHECK AND VERIFY ALL DIMENSIONS, SIZES, REQUIRED CLEARANCES AND SHALL ASSUME FULL RESPONSIBILITY FOR THE FITTING OF ALL EQUIPMENT AND MATERIALS HEREIN REQUIRED TO OTHER PARTS OF THE WORK OF OTHER TRADES. 4. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND LOCATIONS ARE NOT EXACTLY LOCATED. IN THE PREPARATION OF THESE DOCUMENTS, CERTAIN ASSUMPTIONS ARE MADE REGARDING EXISTING CONDITIONS. SOME OF THESE ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT EXPENDING ADDITIONAL SUMS OF MONEY OR DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF EXISTING BUILDINGS AND/OR EQUIPMENT. THEREFORE, THE ENGINEER SHALL NOT BE HELD RESPONSIBLE FOR ANY CHANGES OR ADDITIONAL COSTS INCURRED DUE TO EXISTING CONDITIONS. 5. VELOCITY FOR HOT WATER PIPING LESS THAN 5 FT. PER SECOND CALIFORNIA GREEN COMPLIANCE FORM FIXTURE TYPE DESIGN FLOW RATE (GPM) DURATION DAILY USES OCCUPANTS BASELINE GAL. PER DAY DESIGN GAL. PER DAY STAFF LAV. FAUCET 2.2 0.4 .25 MIN 3 100 880 600 37.5 KITCHEN FAUCET 2.2 1.5 4 MIN 1 URINAL FLUSHOMETER VALVE WATER CLOSET MALE 1.0 0.125 1 FLUSH 2 50 50 12.5 1.6 1.28 1 FLUSH 1 50 64 64 1.6 1.28 1 FLUSH 3 50 192 LAV. FAUCET 2.2 0.4 .25 MIN 0.3 URINAL FLUSHOMETER VALVE WATER CLOSET MALE 1.0 0.125 1 FLUSH 0.2 50 5 1.25 1.6 1.28 1 FLUSH 0.1 50 6.4 6.4 1.6 1.28 1 FLUSH 0.3 50 19.2 19.2 3.75 3 TOTAL DAILY WATER USE (WU) = 1257.85 928.35 ALLOWABLE WATER USE = 1006.28 742.68 IN-SINK ERATOR BADGER 5 CONSTRUCTION: GALVANIZED STEEL MOTOR: 1/2 HP QUIET DURA-DRIVE INDUCTION MOTOR RPM: 1725 ELECTRICAL: WEIGHT: BV BALL VALVE DN PIPE DOWN (U.N., IN WALL) UP PIPE UP (U.N., IN WALL) DN TEE DOWN (U.N., IN WALL) UP TEE UP (U.N., IN WALL) FCO FLOOR CLEANOUT WCO WALL CLEANOUT P.O.C. 11. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL REQUIRED HYDRAULIC CALCULATIONS AND FIRE SPRINKLER HEAD LOCATION IN ACCORDANCE WITH NFPA 13 TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND APPROVAL OF THE FIRE PROTECTION SYSTEM. POINT OF CONNECTION P.O.D. POINT OF DEMOLITION 12. TEST SYSTEM(S) IN ACCORDANCE WITH REQUIREMENTS OF THE GOVERNING AUTHORITIES. AP CONN ACCESS PANEL CONNECTION 13. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE REQUIREMENTS THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT CABINETS, ETC. AND THE ARCHITECT PRIOR TO ANY INSTALLATION. CONT CONTINUATION TP THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ALL PAVED AREAS WHICH ARE EXCAVATED AND/OR DAMAGED BY THEIR OPERATIONS. IN ADDITION, THE CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ALL PLANTED AREAS DAMAGED BY THEIR OPERATIONS. 14. 15. 17. (E) EXISTING (N) NEW DN DOWN ADA AMERICAN DISABILITY ACT ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT INTERRUPTION TIME WILL BE AS SHORT AS POSSIBLE. THE CONTRACTOR SHALL GIVE THE OWNERS REPRESENTATIVE SUFFICIENT NOTICE OF SUCH INTERRUPTIONS AND THE ACTUAL SHUTDOWN TIME SHALL BE AT A TIME DESIGNATED BY THE OWNERS REPRESENTATIVE. (TYP) ALL EXTERIOR WATER SHUT-OFF VALVES BELOW GROUND SHALL BE INSTALLED IN YARD BOXES WITH COVERS CONSPICUOUSLY MARKED "WATER SHUT-OFF" RESPECTIVELY. VTR W/ WHEN REQUIRED BY THE AUTHORITY HAVING JURISDICTION, POTABLE WATER SYSTEMS SHALL BE DISINFECTED AND FLUSHED PRIOR TO USE BY WATER-CHLORINATION SOLUTION AND HAVE BACTERIOLOGICAL EXAMINATION MADE BY AN APPROVED AGENCY PER 2013 CPC SEC. 609.9 AND AS PRESCRIBED IN AWWA C651. METHODS OF CLEANING/ DISINFECTING FOR NEW OR REPAIR PIPING AS DESCRIBED IN C651 OR NFPA 24. FU 18. PLUMBING PIPE, FITTINGS AND FIXTURES USED TO CONVEY OR DISPENSE WATER FOR HUMAN CONSUMPTION SHALL COMPLY WITH AB 1953. 19. ANY SUBSTITUTION MADE BY THE CONTRACTOR THAT IS DIFFERENT FROM WHAT IS SPECIFIED ON THE DRAWINGS SHALL BE CLEARLY INDICATED ON THE SUBMITTAL AS TO ALL THAT IS BEING SUBSTITUTED. IE U.N. PIPE MATERIAL & WEIGHT TYPE OF JOINTS COLD WATER ABV. GROUND COPPER L TUBE SOLDERED HOT WATER ABV. GROUND COPPER L TUBE SOLDERED VENT WASTE & SOIL DRAINS 1 WITH PLUMBING FIXTURE UNIT SECONDARY CONDENSATE UNLESS NOTED PIPES, DUCTS AND CONDUITS SHALL BE SUPPORTED AND BRACED PER THE SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING SYSTEMS", THE "SUPERSTRUT SEISMIC RESTRAINT SYSTEM" FOR PIPES AND CONDUITS ONLY. SHEET INDEX SHUT-OFF RATINGS PSI - SwP VALVE CAST BRONZE/ WROUGHT COPPER 125 BALL GATE CHECK CAST BRONZE/ WROUGHT COPPER 125 BALL CHECK Sheet # P001 P010 P020 P100 P101 P200 Sheet Name PLUMBING LEGEND NOTES & SCHEDULES PLUMBING DEMOLITION PLAN ENLARGED PLUMBING DEMOLITION PLAN OVERALL PLUMBING FLOOR PLAN ENLARGED PLUMBING FLOOR PLANS PLUMBING DETAILS N/A N/A SCHEDULE 40 ABS SOLVENT-WELD ABS N/A N/A NO-HUB CAST IRON NO-HUB 4 BAND N/A N/A N/A AC SOLDERED BRONZE 125 N/A DATE 1 1 TRAP VENT CW RISER HW RISER 3" INT. 2" 1" - WASTE WC 1 Watercloset: Kohler "Kingston" K-4325-L-0 (Left Side Lever), ADA, 17" high rim, standard 15" high rim, (1.28 GPF), wall mounted, elongated bowl, siphon jet, 1-1/2" top spud, white vitreous china. ZER6000AV-HET-CPM (1.28 GPF) sensor operated battery powered flush valve. Olsonite plastic seat model 95 ComfortCurve, elongated, open front, stain & chemical resistant. Josam 12000 Series Wall Carrier. WC 2 Watercloset: Kohler "Kingston" K-4325-0 (Right Side Lever), ADA, 17" high rim, standard 15" high rim, (1.28 GPF), wall mounted, elongated bowl, siphon jet, 1-1/2" top spud, white vitreous china. ZER6000AV-HET-CPM (1.28 GPF) sensor operated battery powered flush valve. Olsonite plastic seat model 95 ComfortCurve, elongated, open front, stain & chemical resistant. Josam 12000 Series Wall Carrier. 3" INT. 2" 1" - L 1 Lavatory: Kohler "Chesapeake" K-1728, white vitreous china, wall hung lavatory w/ faucet holes on 4" centers. Zurn Z81000-XL-3M single handle faucet w/ 0.5 gpm aerator, provide ASSE 1070 approved TMV set to 110°, grid strainer drain w/ 1-1/2" cast brass P-trap with chrome finish, angle stops w/ rigid riser. Provide J.R. Smith 0700 series wall carrier. On ADA compliant provide Truebro Lav Guard per ADA Code 4.19.4 2" 1-1/2" 1-1/2" 1/2" 1/2" S 1 One Compartment Sink: Kohler "Staccato" K-3362-1, 25" x 22" x 8" stainless steel single bowl sink, 19 gauge, self rim, faucet holes on 4" centers. Zurn Z821C0-XL-FC gooseneck faucet, Zurn Z85500-XL-VC-WM double foot pedal mixing valve, chrome basket strainers w/ 1-1/2" cast brass L.A. pattern P-trap with chrome finish, angle stops w/ rigid riser. FLS SS REVISIONS: CONNECTION SIZE: SPECIFICATION No. 33209 A# 03-116477 FIXTURE SCHEDULE SYMBOL FESSIONA PRO L M. J OH N N E IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES N/A COPPER M TUBE ED EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O NO-HUB 4 BAND NO-HUB CAST IRON 14 LBS. 11 OZ. CONDENSATE PRESSURE FITTING MATERIAL TYPICAL VENT THROUGH ROOF ANCHORAGE AND BRACING NOTES PIPE MATERIAL SCHEDULE SERVICE INVERT ELEVATION SEC COND 1. 120V-1ø-60~ 6.9 AMPS WATER HAMMER ARRESTOR & TRAP PRIMER ST MFR. & MODEL NO: CONDENSATE DRAIN WHERE MATERIAL IS SHOWN ON THE DRAWINGS BUT NOT SPECIFIED, IT SHALL BE OF THE SAME TYPE AND QUALITY AS EXISTING MATERIAL. GARBAGE DISPOSAL SCHEDULE GD 1 COND DESCRIPTION DATE GENERAL REVIEW 04-01-2016 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 12" = 1'-0" SCALE: 2" 1-1/2" EE R GIN N SO 26% PLUMBING VENT EN TOTAL WATER CONSUMPTION REDUCTION SAVINGS = GREASE WASTE BELOW GRADE (or FLOOR) 10. 192 100 263.6 GW THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH TITLE 24, CALIFORNIA CODE OF REGULATIONS. 16. TOTAL WATER CONSUMPTION REDUCTION = SOIL or WASTE BELOW GRADE (or FLOOR) 9. VISITORS/CUSTOMERS FLUSHOMETER VALVE WATER CLOSET FEMALE HOT WATER S or W PIPE RISER & PIPE DROP (UP AND DOWN) (U.N., IN WALL) ALL EQUIPMENT AND FIXTURES INSTALLED UNDER THIS CONTRACT SHALL BE HUNG OR ANCHORED IN ACCORDANCE WITH 2013 CPC/CBC. 30 100 FLUSHOMETER VALVE WATER CLOSET FEMALE COLD WATER HW CAP ON END OF PIPE CALCULATIONS BASED ON CHAPTER 8 WORK SHEETS WS-1 & WS-2 BASELINE FLOW RATE (GPM) COND THE INSTALLATION OF ACCESS PANELS OR OTHER INDICATING EQUIPMENT OR SPECIALTIES REQUIRING READING, ADJUSTMENT, INSPECTION, REPAIRS, REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY LOCATED WITH REFERENCE TO THE FINISHED BUILDING. 8. CW V THE CONTRACTOR SHALL COMPLY WITH ALL CONTRACT DOCUMENTS IN LAYING OUT THEIR WORK AND EQUIPMENT. THEY SHALL COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES AND ALL JOB CONDITIONS. 7. MAXIMUM SIZE FOR HOT WATER PIPING SHALL BE 1-1/2" GW ITEMS RELATED TO PLUMBING UTILITIES AND/OR OTHER SERVICE(S); MATERIALS, LABOR, PERMITS, FEES, ETC., SHALL BE VERIFIED WITH THE RESPECTIVE SERVING UTILITY COMPANY PRIOR TO SUBMISSION OF A BID. THE ACT OF SUBMITTING A BID SHALL CONSTITUTE FULL RESPONSIBILITY OF THE CONTRACTOR TO INSTALL SERVICE(S) IN COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING UTILITY COMPANY AND THE MECHANICAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHARGES LEVIED BY THE SERVING UTILITY COMPANY EXCEPTING THE FIRST BILLING DEPOSIT. 6. VELOCITY FOR COLD WATER PIPING LESS THAN 8 FT. PER SECOND EQUIPMENT REFERENCE ID. No. L VELOCITY IA GPM ER F. VALVE REGIST F. TANK FIXTURE IDENIFICATION ID. No. EQUIPMENT V FIXTURE UNITS 3600 Workman Mill Rd, Whittier, CA 90601 THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE WILL BE REQUIRED TO WORK. ALL INDICATED DIMENSIONS ARE APPROXIMATE AND ARE GIVEN FOR ESTIMATE PURPOSES ONLY. FIXTURE UNITS DETAIL REFERENCE SHEET No. FIXTURE S TE 2. PIPE SIZE SCHEDULE DETAIL No. RIO HONDO COLLEGE FIXTURE UNITS ARE BASED ON TABLE A-2 FROM APPENDIX A CLIENT ADDRESS: THE TOTAL INSTALLATION SHALL COMPLY WITH ANY AND ALL REQUIREMENTS OF THE LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION INCLUDING 2013 CBC (CALIFORNIA BUILDING CODE) AND 2013 CMC/CPC (CALIFORNIA MECHANICAL AND PLUMBING CODE). DESCRIPTION OWNER: 1. ABBREVIATION BOOKSTORE AND PRINT SHOP SYMBOL PIPE SIZE IS BASED ON CHART A-4 @ 3.0 P.S.I. / 100 FT. SIZE PLUMBING LEGEND AND SYMBOLS PROJECT NAME: GENERAL NOTES PLUMBING SIZING FORM 1-1/2" 1/2" 1/2" P001 SHEET NUMBER: SHEET TITLE: S 2 Classroom Sink: Elkay Celebrity GECR2521L stainless steel single bowl sink, 20 GA type 304-self rim, 1 faucet holes on centers, Zurn Z825B4-XL gooseneck faucet, Zurn 83600-XL bubbler, chrome basket strainers w/ 11/2" cast brass L.A. pattern P-trap with chrome finish, angle stops w/ rigid riser. On ADA compliant provide Truebro Lav Guard per ADA Code 4.19.4 2" 1-1/2" 1-1/2" 1/2" - FS 1 Floor Sink: Josam 49302 Floor Sink, J.R. Smith #3410 or #3411, 8" square top-medium receptor, 5-7/8" Deep sump, acid resistant coated interior and grate. Provided with trap primer connection for TP-1. 2" 2" 1-1/2" - - TP 1 Trap Primer: MIFAB. model "M-300-BP" 1/2" inlet and 1/2" outlet with optional distribution unit w/ battery pack , may be located as indicated on drawings or as required by code. UPC listed. Provided with a 12"x 12" access panel or larger depending on the required access to the equipment and shut-off valve. (Contractor to verify). 2" 2" 1-1/2" - - 2" 1-1/4" 1-1/2" 1/2" - DF 1 Drinking Fountain: Elkay EHWM17C wall mounted, Hi-Lo dual bubbler drinking water cooler fountain, stainless steel basin w/ integral drain strainer, vandal-resistant bubbler, front & side push pads. ADA compliant & lead free. JS 1 Janitor Sink: Kohler "Whitby" K-6710 white enameled cast iron floor mounted service sink with K-8940 rim guard. Zurn Z842M4, service sink faucet with vacuum breaker, hose threaded outlet, pail hook, integral stops & wall brace. 3" 3" 1-1/2" 1/2" 1/2" U 1 Urinal: Kohler "Bardon" K-4904-ET, ADA 17" high rim, (0.125 gpf), wall hung, white vitreous china, 3/4" top spud, Zurn ZR6003AV-ULF-CPM (0.125 GPF) sensor operated battery powered flush valve. Josam 17560-UR urinal carrier floor mounted bearing plate type. 2" INT. 2" 1" - U 2 Urinal: Kohler "Bardon" K-4904-ET, standard 24" high rim, (0.125 gpf), wall hung, white vitreous china, 3/4" top spud, Zurn ZR6003AV-ULF-CPM (0.125 GPF) sensor operated battery powered flush valve. Josam 17560-UR urinal carrier floor mounted bearing plate type. 2" INT. 2" 1" - PLUMBING LEGEND NOTES & SCHEDULES 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 L 14 admin 173 3/4" COND. 2% SLOPE COND P101 (E) OFFICE FC-1 COND FOR CW & HW PLUMBING WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED PLUMBING FLOOR PLAN 4 P101 (E) SECURITY - STORAGE 10 REGIST (E) 3/4" CW 1 15a (E) 2" CW (E) MICROFILM AND PHOTOGRAPHY AREA 164 (E) LOUNGE - (E) 3/4" HW JAN. - (E) WOMENS RR 4 (E) 4" W (E) 2" CW (E) MENS RR 3 FOR CW & HW PLUMBING WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED PLUMBING FLOOR PLAN 6 FOR WASTE & VENTS WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED PLUMBING FLOOR PLAN 5 AC FLS SS DATE P101 2% SLOPE 1% IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES A# 03-116477 P101 CONNECT (N) 2" W TO (E) 4" WASTE LINE (E) 4" W L ST SAW CUT (E) SLAB AS REQUIRED FOR INSTALLATION OF NEW PIPING. PATCH (E) FLOOR AS REQUIRED TO MATCH (E). (E) 3/4" HW No. 33209 EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O 15 (E) 4" W FESSIONA PRO L M. J OH N N E EE R GIN N SO (E) 3/4" CW ED EN ER hr 163 IA Room 174 FOR WASTE & VENTS WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED PLUMBING FLOOR PLAN 3 3600 Workman Mill Rd, Whittier, CA 90601 K CLIENT ADDRESS: J BOOKSTORE AND PRINT SHOP H PROJECT NAME: G V F S TE E OWNER: D 2% SLOPE C 2% SLOPE 1% B PRINT SHOP 11 RIO HONDO COLLEGE PRINT SHOP PUBLIC LOBBY 12 (E) 4" W 2% SLOPE 1% REVISIONS: FOR WASTE & VENTS WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED 1 PLUMBING FLOOR PLAN FOR CW & HW PLUMBING WORK TO BE PERFORMED IN THIS AREA SEE ENLARGED PLUMBING FLOOR PLAN 2 2" V STAGING 7 1 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 P101 P101 16 (E) MECHANICAL VAULT 4 (E) BUSINESS OFFICE AREA - CLERK ROOM 3 WEEKEND COLLEGE 2 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 (E) 3" CW 1/8" = 1'-0" SCALE: P100 17 SHEET NUMBER: (E) HB SHEET TITLE: OVERALL PLUMBING FLOOR PLAN 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com OVERALL PLUMBING FLOOR PLAN 1/8" = 1'-0" 1 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 FOR CONNECTION TO STRUCTURE & PIPE SUPPORT SEE DETAILS 3. TRAP PRIMER DETAILS SEE 4. NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE, ACCORDING TO THE METHOD SET IN SECTION 609.9 OF THE CPC. 5. CONTRACTOR SHALL PATCH FLOORS, WALLS & CEILINGS TO MATCH NEW CONSTRUCTION PER ARCHITECTS SPECIFICATIONS. 6. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRANCHES, RUNS TOO RISERS AND WHERE SHOWN ON DRAWING. LOCATE SHUT-OFF VALVES OVER TBAR CEILING WHEN POSSIBLE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATED OVER HARD LID CEILINGS. G 15a 1-1/2" V DF 1 H 5 1,2,5 P200 3 P200 15a RIO HONDO COLLEGE (E) FCO 15 2" W 1 (E) COTG (E) 2" V UP TO ABOVE 4 14 1 (E) 4" W 4 5 1-1/2" V (E) FCO FOR CONTINUATION SEE 1 (E) 4" W FOR CONTINUATION SEE 1 P100 L 1 1 U 2 1 (E) 4" W COND P100 U 1 1 S 1 WCO WC 2 13 1 15 5 4 FOR CONTINUATION SEE 1 3/4" COND 8 FOR CONTINUATION SEE 1 15 WC 2 1-1/2" V B.F.G. P100 L 1 14 13 (E) 4" W 2" W 1 FD 1 2" W 4 FD 1 WC 2 WC 2 1 2" W 2" V 2" V 1-1/2" V B.F.G. 15 2" W P100 2" W L 1 1 WC 1 1 1-1/2" V GD S 2 OWNER: (E) 2" V (E) 4" W 1 1 16 WCO WC 1 1 JS 1 1 3600 Workman Mill Rd, Whittier, CA 90601 2. CLIENT ADDRESS: FOR LINE TYPES, SYMBOLS & ABBREVIATIONS SEE LEGEND ON SHEET P001 PROJECT NAME: F 1. BOOKSTORE AND PRINT SHOP GENERAL NOTES J (E) 4" W 16 V ER 1 P100 FESSIONA PRO L M. J OH N N E S TE REGIST 1 P100 ED No. 33209 EE R GIN N SO FOR CONTINUATION SEE EN FOR CONTINUATION SEE ST IA L EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O FS 1 CONSTRUCTION NOTES PLUMBING WASTE & VENT FLOOR PLAN 5 1/4" = 1'-0" PLUMBING WASTE & VENT FLOOR PLAN 3 1/4" = 1'-0" PLUMBING WASTE & VENT FLOOR PLAN 1 1/4" = 1'-0" J FOR CONTINUATION SEE 1 P100 (E) 3/4" CW F 15a G (E) 2" CW 3 (E) 2-1/2" CW (E) 2-1/2" CW 11 2 14 2 CONNECT (N) 3/4" CW TO (E) CW LINE. 3 CONNECT (N) 3/4" HW TO (E) HW LINE. 4 CONNECT (N) 2" WASTE TO (E) WASTE LINE. 5 CONNECT (N) 1-1/2" VENT TO (E) VENT LINE. 6 1/2" CW DN IN WALL TO TRAP PRIMER W/ SOV AT RISER BEHIND ACCESS PANEL. 7 3/4" CW & HW DN IN WALL TO FIXTURE. 8 3/4" COND. DN IN WALL TO TAILPIECE OF SINK SEE DETAIL 9 3/4" CW DN IN WALL TO FIXTURE. 10 CONNECT (N) 1/2" CW TO (E) CW LINE. 11 1/2" CW DN IN WALL TO FIXTURE. 12 CONNECT (N) 1/2" CW TO (E) CW HEADER IN CHASE. 13 CONNECT (N) FIXTURE TO (E) PLUMBING HEADERS IN CHASE. REWORK PIPING AS NEEDED FOR (N) CONNECTION. 1 CONNECT (N) 2" VENT TO (E) VENT LINE. 15 A# 03-116477 AC FLS SS DATE REVISIONS: 5 P200 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 SAW CUT (E) SLAB AS REQUIRED FOR INSTALLATION OF NEW PIPING. PATCH (E) FLOOR AS REQUIRED TO MATCH (E). FOR CONTINUATION SEE 1 P100 DF 1 (E) 3/4" HW WC 2 13 (E) FIXTURE TO BE REPLACED & RELOCATED. RE-WORK EXISTING PIPING AS NEEDED FOR CONNECTION TO (E) FIXTURE. 14 15a H 1 IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 1 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 1/2" CW 1/4" = 1'-0" SCALE: 10 3/4" HW 10 3/4" CW 7 3 U 1 (E) 1/2" HW 3/4" HW (E) 2-1/2" CW UP TO ABOVE 2 3/4" CW S 1 L 1 1 L 1 1 SHEET TITLE: L 1 (E) 2-1/2" CW WC 2 WC 2 WC 2 1 FD 1 1 FD 1 (E) 3/4" CW WC 1 16 S 2 GD 1 1 1/2" TP (E) 3" CW TP 1 ENLARGED PLUMBING FLOOR PLANS 13 1/2" TP 1/2" CW P101 SHEET NUMBER: 1 1 (E) 3/4" HW U 2 1 KEY PLAN 7 12 1 WC 1 JS 1 1 16 FOR CONTINUATION SEE 1 FOR CONTINUATION SEE 1 P100 P100 FOR CONTINUATION SEE 1 6 TP 1 P100 FS 1 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 1/2" TP Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com PLUMBING DOMESTIC WATER FLOOR PLAN 1/4" = 1'-0" 6 PLUMBING DOMESTIC WATER FLOOR PLAN 1/4" = 1'-0" 4 PLUMBING DOMESTIC WATER FLOOR PLAN 1/4" = 1'-0" 2 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 21" MAX. UNISTRUT P1000 DIAGONAL BRACE WHERE REQUIRED SEE DETAILS 3,4,13 COUPLER - 6" MAX. HANGER & STIFFENER PER DETAILS 3,4,13 - HANGER ROD ELEVATION VIEW 1 ROD STIFFENER 4 CONNECTION TO STRUCTURE 1 ATTACH TO STRUCTURE ABOVE PER 6" MAX 1 - COUPLER AS REQD. OWNER: 1/2"Ø ROD @ 10'-0" OC MAX (W/ P1000 STIFFENER PER WHERE BRACE OCCURS SECONDARY CONDENSATE 4'-0" MAX FC - DRAIN PAN CONDENSATE CONNECTION W/O PUMP 6" MAX L 4"Ø MAX PIPE PER PLAN TYP. INSULATION PER INSULATION SCHEDULE ON SHEET M001 IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES CLEVIS PIPE CLAMP 5 6" MIN. RIGID INSULATION EA. SIDE OF CLAMP ATTACH TO STRUCTURE ABOVE PER 1 A# 03-116477 6" MIN EA SIDE OF CLAMP, TYP AC UNISTRUT SPF100 W/ 1/2"Ø BOLT AND SPRING NUT (P1010) TO DIAGONAL BRACE 4" MAX. FLS SS DATE PIPE CLAMP - COUPLER AS REQD. 6" MAX EXP. 9-30-2017 ME A AT C H A N I C RN E O F CA L I F O 45° ±10° NUT ABOVE AND BELOW No. 33209 ST NOTE: THE SECONDARY DRAIN PAN SHALL HAVE A MINIMUM DEPTH OF 1.5 INCHES (38 MM), SHALL NOT BE LESS THAN 3 INCHES (76 MM) LARGER THAN THE UNIT OR THE COIL DIMENSIONS IN WIDTH AND LENGTH AND SHALL BE CONSTRUCTED OF CORROSION-RESISTANT MATERIAL. THE BOTTOM PANEL OF THE PAN SHALL BE CONTOURED OR SLOPED. METALLIC PANS SHALL HAVE A MINIMUM THICKNESS OF NOT LESS THAN 0.0276-INCH (0.7 MM) GALVANIZED SHEET METAL. NONMETALLIC PANS SHALL HAVE A MINIMUM THICKNESS OF NOT LESS THAN 0.0625 INCH (1.6 MM). A WATER LEVEL DETECTION DEVICE CONFORMING TO UL 508 SHALL BE PROVIDED THAT WILL SHUT OFF THE EQUIPMENT SERVED IN THE EVENT THAT THE PRIMARY DRAIN IS BLOCKED. THE DEVICE SHALL BE INSTALLED IN THE DRAIN PAN, LOCATED BELOW THE OVERFLOW RIM OF PAN. FESSIONA PRO L M. J OH N N E EE R GIN N SO - SECONDARY CONDENSATE PAN ED EN P1000 LONGITUDINAL BRACE (8'-0" MAX LENGTH) AT 20'-0" OC MAX & 24" MAX FROM ANY BEND IN PIPE. ATTACH TO STRUCTURE PER 1 ER N.C. MOISTURE SENSOR, INTERLOCK TO SYSTEM CONTROLLER POWER REGIST 1 RIO HONDO COLLEGE 9'-8" 3600 Workman Mill Rd, Whittier, CA 90601 UNISTRUT P1843 ANGLE CLIP IA 1 CLIENT ADDRESS: PLAN VIEW BOOKSTORE AND PRINT SHOP 1/2"Ø HILTI KB TZ W/ 3-1/4" MIN. EMB. STRUT CHANNEL, UNISTRUT P1000 OR B-LINE B22 21" MAX. PROJECT NAME: (E) 8-1/2" MIN THICK PRETENSIONED CONCRETE ROOF / FLOOR. ROD STIFFENER CLAMP S TE 6" MAX. LOCATE (E) REINFORCING AND (E) POSTTENSIONING CABLES BY NON-DESTRUCTIVE METHODS PRIOR TO DRILLING. DO NOT DAMAGE (E) REINFORCING AND (E) POSTTENSIONING CABLES. V ROD STIFFENER CLAMP, UNISTRUT P2486 OR B-LINE SC228 PIPING SUPPORT SCHEDULE 1/2"Ø ROD @ 10'-0" OC MAX (W/ P1000 STIFFENER PER WHERE BRACE OCCURS 2 REVISIONS: 1 1/2" CW SUPPLY DESCRIPTION DATE GENERAL REVIEW 04-01-2016 TRAP PRIMER TP BALL VALVE 4'-0" MAX 1/2" CW (TYP) P1000 TRAVERSE BRACE (8'-0" MAX LENGTH) AT 20'-0" OC MAX & 6" MAX FROM ANY BEND IN PIPE. ATTACH TO STRUCTURE PER 1 - TRAP PRIMER VALVE - FS - BALL VALVE REFER TO PLANS FOR SIZE AND LOCATION ACCESS PANEL FLOOR 1/2" CW 6" MAX 45° ±10° NUT ABOVE AND BELOW NOTE: ACCESS PANEL SHALL NOT BE INSTALLED BEHIND GRAB BARS. 3" UNISTRUT SPF100 W/ 1/2"Ø BOLT AND SPRING NUT (P1010) TO DIAGONAL BRACE DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 12" = 1'-0" SCALE: P200 SHEET NUMBER: CLEVIS PIPE CLAMP TRAP PRIMER 6"Ø MAX PIPE PER PLAN W/ RIGID INSULATION EXTENDING 6" BEYOND EA. SIDE OF CLAMP PIPE SUPPORT - TRAVERSE BRAC FOR CONNECTION TO STRUCTURE SEE 1 FOR CONNECTION TO STRUCTURE SEE 1 - - STIFFNER CLAMP ASSEMBLY 4 (TYP.) PER 3 SHEET TITLE: PLUMBING DETAILS 6 UNISTRUT P1000 TRAVERSE BRACE - STIFFNER UNISTRUT P1000 LONGITUDINAL BRACE B-LINE FIG. B3380 THRU B3384 45° MIN . M LOCK NUT & UNISTRUT P1000 WASHER (TYP.) MAX SPAN = 3'-0" AX G N LE TH = " -0 9' UNISTRUT SPF 100 W/ 1/2"Ø BOLT AND SPRING NUT (P1010) TO DIAGONAL BRACE SPRING NUT (TYP.) NOTES: 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 1. 2. 3. Phone: 909.890.3700 Fax: 909.890.3770 HANG TRAPEZE AT 6'-0" ON CENTER UNISTRUT P1000 LONGITUDINAL BRACE AT 20'-0" MAX ON CENTER MAX. 4 PIPES AT MAX. 4"Ø EACH OR MAX. 2 PIPES AT MAX. 6"Ø EACH. email: info@designwesteng.com TRAPEZE PIPE SUPPORT 7 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 AP2 - 30 14 AP2 - 26 drill J AP2 - 2 11 (E) 27 4 AP2 - 4 5 SM EF AP2 - 16 AP2 - 32 1 (E) xerox nuvera AP2 - 18 (E) hand wash sink SM 7 AP2 - 20 work table 5 5 FC 2 AP2 - 22,24 COORDINATE POWER AND DATA DEVICE LOCATIONS, AND DEVICE PLATE COLOR WITH ARCHITECT. 2. REFER TO MECHANICAL PLANS FOR THE EXACT LOCATION OF HVAC EQUIPMENT AND ADDITIONAL WIRING REQUIREMENTS. 3. PROVIDE DUCT DETECTOR POWER AND CONNECTIONS AS INDICATED ON MECHANICAL DRAWINGS. 4. PROVED FLEXIBLE SEAL TYPE CONDUIT FOR CONNECTION TO ALL HVAC EQUIPMENT. 5. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE NEMA 3R. 6. ALL EXTERIOR RECEPTACLE OUTLETS SHALL BE GFCI TYPE. 7. PROVIDE HEAVY DUTY DISCONNECT SWITCHES WITH DUAL ELEMENT FUSES TO MATCH MOTOR H.P. RATING. 8. REFER TO FOLLETT PLANS FOR ADDITIONAL INFORMATION AND ELECTRICAL REQUIREMENTS. 30 (E) AP2 - 27 work table SF 1 J 27 14-50R AP2 - 29,31,33 SM paper cutter 2 stapler (E) 2 1. EF 2 1 F AP2 - 6 6 PRINT SHOP 11 (E) AP2 - 19 AP2 - 13,15,17 10-30R RIO HONDO COLLEGE color copier xerox nuvera (E) 19 AP2 - 5,7 6-20R CR paper cab. PRINT SHOP PUBLIC LOBBY 12 (E) VAV-C 8 xerox 4595 (E) (E) (E) AP2 - 35 35 AP2 - 10 work table 35 AP2 - 21,23,25 14-50R PANEL 'AP2' (E) VAV-C (E) VAV-C (E) 28 10 (E) 11 (E) VAV-D AP2 - 28 AP2 - 11 xerox 4595 8 AP2 - 1,3 6-20R STORAGE 10 desk L AP2 - 8 9 OWNER: AP2 - 9 15 CR AP1 - 22 J ER LE O REGIST 15a 16 32 32 No. E19480 Exp. 6-30-2017 EL A AT E C T R I C RN E O F CA L I F O ST IA L 32 EE R GIN YA 16 FESSIONA PRO L RD P. M A N A EN ED SFD 3600 Workman Mill Rd, Whittier, CA 90601 K CLIENT ADDRESS: J PROJECT NAME: H G BOOKSTORE AND PRINT SHOP GENERAL NOTES AP1 - 32 AP1 - 16 38 AP1 - 38,40 CONSTRUCTION NOTES 1 1 40 32 (E) 2 PROVIDE AND INSTALL 30A 2P NEMA 1 RATED FUSED DISCONNECT. FUSING PER MECHANICAL EQUIPMENT MANUFACTURERS REQUIREMENTS. VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL CONTRACTOR. 3 PROVIDE AND INSTALL 208V 1P MOTOR RATED SNAP SWITCH. FAN COIL TO BE POWERED BY HEAT PUMP UNIT (REFER TO MECHANICAL PLANS FOR EXACT LOCATION). REFER TO MECHANICAL PLANS FOR WIRING INFORMATION. 4 PROVIDE AND INSTALL 30A 2P H.D. WEATHERPROOF NEMA 3R RATED FUSED DISCONNECT. FUSING PER MECHANICAL EQUIPMENT MANUFACTURERS REQUIREMENTS. VERIFY EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL CONTRACTOR. 10 J (E) STAGING 7 AP1 - 14 14 (E) 8 27 3 J 2 J AP1 - 33,35 35 AP1 - 27 10 10 J J S AP1 - 30 AP1 - 36 J (E) VAV-E 33 (E) VAV-E 5 12 OFFICE 5 AP1 - 10,12 OFFICE 6 P J +72" +72" 14 14 J 1 1 6 PROVIDE 120V POWER FOR EAS SYSTEM. VERIFY EXACT LOCATION AND REQUIREMENTS WITH FOLLETT PLANS PRIOR TO INSTALLATION. 7 PROVIDE LOW VOLTAGE TRANSFORMER FOR FAUCET SENSOR. VERIFY EXACT LOCATION AND REQUIREMENTS WITH PLUMBING CONTRACTOR. 8 PROVIDE 120V POWER TO GARBAGE DISPOSAL. 9 PROVIDE POWER TO SERVER CABINET COOLING EQUIPMENT. VERIFY EXACT REQUIREMENTS WITH IT EQUIPMENT MANUFACTURE. 10 PROVIDE 4S JUNCTION BOX FOR CAMPUS/FOLLETT LOW VOLTAGE/SECURITY CONNECTION. IF INSTALLED IN AREA WITH EXPOSED STRUCTURE ABOVE OR HARD LID CEILING, PROVIDE 3/4" C.O. BACK TO LOCATION OF NEAREST IDF/MDF. VERIFY EXACT LOCATION AND REQUIREMENTS WITH CAMPUS PRIOR TO INSTALLATION. +18" 10 P 16 11 PROVIDE 120V POWER AND (1) 1" CONDUIT DOOR STRIKER TO ACCESSIBLE CEILING SPACE FOR EXIT ALARMED DOOR. VERIFY EXACT REQUIREMENTS WITH MANUFACTURE INSTALLATION REQUIREMENTS. 12 J FLS SS DATE REVISIONS: 1 DESCRIPTION DATE GENERAL REVIEW 04-01-2016 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 1/4" = 1'-0" SCALE: 10 E201 SHEET NUMBER: +18" 10 SHEET TITLE: 26 9 1 AC +18" 28 (E) FC-3 AP1 - 11,13 11 ENLARGED BOOKSTORE POWER & SIGNAL FLOOR PLAN +18" (E) VAV-F A# 03-116477 AP1 - 31 FOLLETT BOOKSTORE 15 9 +72" 3 AP1 - 5,7,9 7 12 AP1 - 1 AP1 - 3 1 PROVIDE AND INSTALL NEMA 1 MOTOR RATED SNAP SWITCH. INTERCONNECT EXHAUST FAN TO MECHANICAL UNIT PER MECHANICAL PLANS. 30 31 33 5 11 30 PROVIDE AND INSTALL J-BOX ABOVE FINISHED CEILING WITH (2) 20AMP 120V CIRCUITS AND (1) 3/4" CONDUIT STUBBED OUT 6'-0" A.F.F. SCHOOL GC TO INSTALL (2) EMPTY 3/4" CONDUIT W/ PULL STRING STUBBED OUT HERE AT 6" A.F.F. AND STUBBED ABOVE FINISHED CEILING FOR FOLLETT DATA . REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION. IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 28 AP1 - 26,28 28 (E) VAV-H 13 CLERK ROOM 3 WEEKEND COLLEGE 2 VAULT 4 +18" 26 15 AP1 - 15,17,19 +18" 3 SM 17 +18" KEY PLAN 28 19 FC 2 10 +18" 21 4 AP1 - 24 1 AP1 - 18,20 26 26 SF 2 SM 5 HP 2 (VERIFY LOCATION WITH MECHANICAL CONTRACTOR) 23 21 23 J F 10 26 AP1 - 25 AP1 - 29 1 J +126" J +126" J 25 J J AP1 - 21,23 25 17 N 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com ENLARGED BOOKSTORE POWER & SIGNAL FLOOR PLAN 1/4" = 1'-0" 1 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 L 1. COORDINATE LIGHT FIXTURE LOCATIONS AND LIGHT SWITCH LOCATIONS, COLOR, AND STYLE WITH ARCHITECT. 2. WHERE MOTION SENSORS ARE SHOWN ON PLANS, VERIFY WATTAGE AND COVERAGE OF PRODUCT PROVIDED IS ADEQUATE FOR SPACE TO BE CONTROLLED. COVERAGE IS TO BE ADJUSTED TO AVOID ACCIDENTAL ACTIVATION OUTSIDE OF AREA. VERIFY WIRING REQUIREMENTS TO MOTION SENSORS, RELAY PACKS, ETC WITH PRODUCT BEING PROVIDED. 14 F1E 8 8 EB 3 F1 8 F1 8 F1 8 F1E 8 8 EB 3 PRINT SHOP 11 F1 8 F1 8 F1E 8 8 EB 3 F1 8 F1 8 (E) OFFICE - RIO HONDO COLLEGE AP1 - 8 (E) SECURITY - F6E 8 EB F2 8 F2 8 F1 8 ? ? F4 8 F2 8 F2 8 F2E 8 8 EB 3 F4 8 PANEL 'AP2' F1E 8 8 EB 3 PRINT SHOP PUBLIC LOBBY 12 F4 8 F6E 8 EB OWNER: F2 8 15 1 F1 F1E F1 F1 F1E F1 F1 F1E 6 5 6 6 5 6 6 5 ER LE O REGIST EE R GIN YA FESSIONA PRO L RD P. M A N A EN ED No. E19480 Exp. 6-30-2017 EL A AT E C T R I C RN E O F CA L I F O ST IA L 15a 3600 Workman Mill Rd, Whittier, CA 90601 K CLIENT ADDRESS: H PROJECT NAME: G BOOKSTORE AND PRINT SHOP GENERAL NOTES F1 2 F1E 2 3 2 EB F1 2 F1 2 F5 4c F5E 3 4c 4 EB F5 4c 3 F5E 4c 4 EB F5 4c CONSTRUCTION NOTES AP1 - 4 F1 2 F1 2 F1 2 F1 2 1 PROVIDE LOW VOLTAGE PHOTOCELL. REFER TO WIRING DIAGRAM FOR ADDITIONAL INFORMATION. 2 DAYLIT AREA, PER CALIFORNIA ENERGY CODE. 3 PROVIDE NON-SWITCHED 'HOT' POWER WIRE TO BATTERY PACK CHARGING/SENSOR IN FIXTURE. 4 CIRCUIT LIGHTING TO EXISTING LIGHTING CIRCUIT IN ROOM. 5 CONNECT NEW LIGHT FIXTURE TO EXISTING EMERGENCY CORRIDOR CIRCUIT. 6 CONNECT NEW LIGHT FIXTURE TO EXISTING NON-EMERGENCY CORRIDOR CIRCUIT. IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES A# 03-116477 AC 1 F1 2 3 AP1 - 2 3 F1 2 F5E 4c 4 EB F5 4c F5E 3 4c 4 EB F5 4c SS DATE REVISIONS: 1 STAGING 7 FLS DESCRIPTION DATE GENERAL REVIEW 04-01-2016 F5E 3 4c 4 EB F1E 2 3 2 EB F1 2 F6E 2 EB FOLLETT BOOKSTORE 15 F1 2 16 F1 2 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 1/4" = 1'-0" SCALE: F5 6b F1 2 F1E 2 3 2 EB OFFICE 6 F5 6b F5 6b F5 6b F5 6b OFFICE 5 E301 SHEET NUMBER: SHEET TITLE: CLERK ROOM 3 F3 F3 F2 2 F2 2 F2 2b F3 F3 F2 2 F2 2 F2 2b F2 2b WEEKEND COLLEGE 2 ENLARGED BOOKSTORE LIGHTING FLOOR PLAN 3 AP1 - 6 VAULT 4 F2 2b 1 2 F3 F3 F2 2 F2 2 F2 2a F5E 3 6a 6 EB F5 6a 2 F5 6a F5E 3 6a 6 EB 1 KEY PLAN F5 6a F2 2a F6E 6 EB F6E 6 EB 17 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 N Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com ENLARGED BOOKSTORE LIGHTING FLOOR PLAN 1/4" = 1'-0" 1 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312 HARD LID CEILING WITH NO ATTIC SPACE ABOVE. PROVIDE NEW SURFACE MOUNTED RACEWAY PER NOTE '2' AND NEW ACCESS PANEL PER NOTE '1'. CT-C HARD LID CEILING WITH ATTIC SPACE ABOVE. PROVIDE ACCESS PANEL FOR EACH ABOVE CEILING HEAT DETECTOR. PROVIDE NEW SURFACE MOUNTED RACEWAY WHEN NECESSARY, SEE NOTE #2. CT-D HARD LID CEILING WITH ATTIC SPACE ABOVE. ATTIC SPACE COVERED WITH LINEAR HEAT DETECTOR, SEE ATTIC SPACE PLAN. NEW FIRE ALARM CONDUIT SHALL BE INSTALLED ABOVE CEILING. CT-F EXPOSED BEAM CEILING. 2 3/4" C - 2#12 + 12G TO (E) 120V PANEL. 2. 3 PROVIDE MONITOR MODULE FOR LINEAR HEAT DETECTOR CONNECTION SEE ATTIC SPACE PLANS. 4 REFER TO SHEET '1'/E002 FOR RPS QUANTITY. SMOKE DETECTOR SHALL NOT BE MOUNTED LESS THAN 12" FROM EXISTING LIGHTING FIXTURES AND LESS THAN 36" FROM EXISTING HVAC REGISTERS. CONTRACTOR SHALL PROVIDE NEW 24"X24" ACCESS PANEL(S),FOR CEILING. HEAT DETECTOR LOCATIONS PROVIDE FIRE RATED ACCESS PANELS SHALL BE USED IN THESE AREAS. 3. NEW SURFACED MOUNTED RACEWAY SHALL BE SECURED TO CEILING OR WALL JOISTS, NO TOGGLE BOLTS ARE ALLOWED. 4. CONTRACTOR SHALL FIELD VERIFY EXISTING WALL CONDITION PRIOR TO INSTALLATION OF ALL NEW WALL MOUNTED WIREMOLDS, OUTLETS, EQUIPMENT, ETC. TO AVOID ANY INTERFERENCE WITH EXISTING INSTALLATIONS. CONTRACTOR SHALL ROUTE NEW FIRE ALARM RACEWAY TO AVOID ALL EXISTING RACEWAY, EQUIPMENT, DEVICES, ETC. 5. FIRE ALARM CONDUIT SHALL BE 3/4" MINIMUM UNLESS OTHERWISE NOTED. WIREMOLD SHALL HAVE EQUIVALENT OR LARGER CAPACITY IF REQUIRED. 6. SEE RISER DIAGRAM FOR FA CABLING DETAILS. 7. CONCEAL ALL CONDUIT ABOVE DROP CEILING. CONTRACTOR SHALL REMOVE TILES AND RUNNERS AS NECESSARY FOR A COMPLETE INSTALLATION. ALL DAMAGED TILES SHALL BE REPLACED WITH NEW TILES THAT MATCH EXISTING TILES. ALL RUNNERS SHALL BE RE-INSTALLED AND INSPECTED. E B C F 1. REFER DETAILS FOR NEW ACCESS PANEL INSTALLATION. 2. NEW SURFACE MOUNTED WIREMOLD RACEWAY SHALL BE USED UNDER HARD LID CEILING AND EXPOSED BEAM AREAS. G J K OWNER: NOTES L 3600 Workman Mill Rd, Whittier, CA 90601 CT-B 1. CLIENT ADDRESS: T-BAR CEILING WITH ACCESSIBLE SPACE ABOVE. NEW FIRE ALARM CONDUIT SHALL BE INSTALLED ABOVE CEILING. PROVIDE NEW 20A 1 POLE CIRCUIT BREAKER TO MATCH EXISTING & PROVIDE LOCKON DEVICE. BOOKSTORE AND PRINT SHOP CT-A 1 RIO HONDO COLLEGE CEILING TYPE IDENTIFICATION GENERAL NOTES PROJECT NAME: CONSTRUCTION NOTES D H S3 173 CT-A SD CT-A 1D,1V,1A SD L=530' V.D.=4.01% 1D,1V,1A 1D,1V,1A S3 30cd 1A-8,1V-7 2D 175 2D 1D admin 171 SD 177 163 1D,1V,1A 2D admin 166 CT-A SD 198 S 1D 1V,1A SD CT-A 2D 3 1A L=350' V.D.=1.93% 1D,1V,1A SD M SEE FA ATTIC SPACE PLANS 2D info 180 S S4 30cd 1A-5,1V-5 CT-A (E) LOBBY 1D,1V,1A A100 SD 125 SD 1D,1V,1A S SD 2D,2V,2A SD 2D admin 168 S SD CT-A SD SD 1D,1V,1A CT-A 121 S4 15cd 1A-3,1V-3 S4 15cd 1A-2,1V-2 115 SD 122 S S2 15cd 1A-10,1V-10 1D,1V,1A S 1D,1V,1A (E) OFFICE 122G CT-A SD 1D,1V,1A CT-A (E) OFFICE-2 --2 (E) OFFICE-1 --1 120 SD 1D,1V,1A CT-A Space 183 CT-A (E) OFFICE-1 122B-1 119 SD 1D,1V,1A 1D,1V,1A SD 117 SD S S4 15cd 1A-1,1V-1 118 1D,1V,1A CT-A 1D,1P S A# 03-116477 145 1V,1A 142 SD 146 SD 140 (N) 'FAA' 2D,2V,2A STORAGE 10 2D,2V,2A AC SD CT-C CT-D 15 S5 30cd 1A-4,1V-4 S5 30cd 1A-3,1V-3 2D,2V,2A 190 SD 2D,2V,2A 192 SD 193 2D REVISIONS: 3 194 S M 1 2D,2V,2A 1D,1V,1A 1D,1V,1A 182 S 187 HD S5 15cd 1A-2,1V-2 STAGING 7 2V,2A 181 SD (E) WOMENS RR 4 S1 1A-10 S5 15cd 1A-1,1V-1 CT-C S SD 15a 1D,1V,1A M S1 75cd 1A-3,1V-3 136 138 SD SD 2D 2D 2D,2V,2A 1D,1V,1A S SEE FA ATTIC SPACE PLANS 191 139 C HD DESCRIPTION DATE GENERAL REVIEW 04-01-2016 WP 131 188 1D,1V,1A SS 3 SD CT-C FLS DATE 1D,1V,1A 2V,2A S CT-A S1 30cd 1A-7,1V-6 S SEE FA ATTIC SPACE PLANS S1 30cd 1A-9,1V-8 1D,1V,1A (E) MENS RR 3 CT-C 1D,1V,1A SD 180 S1 30cd 1A-2,1V-2 CT-C SD 2D,2V,2A 130 SD CT-C 108 SD (E) MECHANICAL - 106 (E) OFFICE 122A SD 16 DATE ISSUED: 11-11-2015 PROJECT NO: 2014-40156 CT-A 1D CT-A 2D,2V,2A (E) OFFICE-2 SD 122B-2 S2 30cd 1A-5,1V-5 S SD SD 1D,1V,1A (E) OFFICE 122C SD 1D,1V,1A (E) BEAMS (N) PANEL 'FACP' & 'FATC-1' 104 CT-A 2 (E) BEAMS 1D SD 100 1D,1V,1A 1D,1V,1A SD S 1D,1V,1A VAULT 4 1 103 CT-C 129 CLERK ROOM 3 CT-A SD 1D,1V,1A S S1 30cd 1A-1,1V-1 M SEE FA ATTIC SPACE PLANS 1D SD FOLLETT BOOKSTORE 15 WEEKEND COLLEGE 2 132 2D 1D,1V,1A S1 30cd 1A-5,1V-5 SHEET TITLE: 137 SD S 2D,2V,2A 128 FA101 SHEET NUMBER: 135 2D,2V,2A SD (N) RPS 4 1D,1V,1A SD TO FATC-1 1D S2 30cd 1A-4,1V-4 SD 134 2D 101 107 S CT-A 105 CT-A 133 CT-F 1/8" = 1'-0" SCALE: OFFICE 5 OFFICE 6 TO FATC-1 102 1D,1V,1A S 1D,1V,1A CT-A 2D,2V,2A (E) BUSINESS OFFICE AREA - 1D,1V,1A IDENTIFICATION STAMP DIVISION OF THE STATE ARCHITECT OFFICE OF REGULATION SERVICES 1D,1V,1A HD 1D,1V,1A (E) OFFICE 122H S SD 1D,1V,1A 1D,1V,1A (E) VAULT 109 S CT-A 1D,1V,1A 186 SD 183 1D,1V,1A 1D,1V,1A SD 3 2V,2A 1 113 2D 1D,1V,1A TO FATC-1 2D,2V,2A 2V,2A SD 2D 116 S2 30cd S 1A-9,1V-9 1D,1V,1A 1D,1V,1A 114 (E) SD PURCHASING 122J 185 S C S CT-A SD 1D,1V,1A S2 15cd 1A-6,1V-6 112 1D,1V,1A M 2D,2V,2A 189 2D,2V,2A L=225' EOLD V.D.=2.06% JAN. - 143 1D,1V,1A CT-A CT-A CT-A SD 1D,1V,1A EOLD S1 L=435' 15cd 1A-13,1V-11 V.D.=5.71% 2D 148 2D 184 S2 30cd 1A-1,1V-1 109 2D,2V,2A CT-A 1D,1V,1A S CT-A 1D,1V,1A (E) FINANCE 179 1D,1V,1A S2 30cd 1A-2,1V-2 (E) MICROFILM AND 2V,2A PHOTOGRAPHY AREA 164 110 S 1D,1V,1A CT-A 2V,2A (E) OFFICE - SD SEE FA ATTIC SPACE PLANS SD 111 S CT-A S2 15cd 1A-7,1V-7 (E) OFFICE - CT-A M (E) LOUNGE - 123 S4 30cd 1A-4,1V-4 (E) OFFICE - SEE FA ATTIC SPACE PLANS 1D,1V,1A 195 S3 30cd 1A-1,1V-1 147 SD SD C 2D,2V,2A 1D,1V,1A CT-A S CT-A 1D,1V,1A 161 S5 15cd 1A-7,1V-7 CT-A 2D,2V,2A S4 30cd 1A-6,1V-6 126 SD S S 2V,2A 2D S2 15cd 1A-8,1V-8 SD CT-A 2D (E) CORRIDOR - SD (E) BOARD CONFERENCE ROOM 106 WP 1D,1A S5 30cd 1A-5,1V-5 158 144 SD 157 3 1D,1V,1A 196 (E) BOARD ROOM 102 S EOLD 197 3 CT-A S4 1A-7 S5 30cd 1A-6,1V-6 124 127 S3 30cd 1A-2,1V-2 1D,1V,1A 164 SEE FA ATTIC SPACE PLANS L=450' EOLD V.D.=2.48% SD 1D,1V,1A PRINT SHOP PUBLIC LOBBY 12 2V,2A C STORAGE - 141 CT-A No. E19480 Exp. 6-30-2017 EL A AT E C T R I C RN E O F CA L I F O CT-A 149 150 S1 PRINT SHOP 30cd 11 1A-11,1V-9 (E) SECURITY - S SD SD S SD CT-A 1D,1V,1A S1 30cd 1A-12,1V-10 1D,1V,1A 1D,1V,1A 1D,1V,1A S S3 30cd 1A-4,1V-4 2V,2A 151 SD (E) OFFICE - 2D,2V,2A S CT-A S CT-A 159 M SEE FA ATTIC SPACE PLANS (E) OFFICE - CT-A 160 M admin 181 1D,1V,1A 170 SD 2D 162 SD 169 CT-A 3 CT-A SD admin 172 2D SD CT-C 2D CT-A 156 (E) OFFICE - 2V,2A hr 163 2D SD SD 1D,1V,1A 1D,1V,1A (E) OFFICE - (E) OFFICE-3 --3 SD 2D CT-A SD 174 178 elec. 19 S3 30cd 1A-6,1V-5 176 SD SD 2D 2D T 1D admin 169 S S S3 30cd 1A-3,1V-3 HD CT-A S3 15cd 1A-7,1V-6 165 166 S EOLD CT-A 2D,2V,2A S 1D,1V,1A mail 165 1D,1V,1A 172 179 SD 1D,1V,1A 171 SD CT-A SD 1D,1V,1A 152 SD SD 155 S S1 30cd 1A-8,1V-7 FIRST FLOOR FIRE ALARM PLAN 1D,1V,1A CT-A 1D,1V,1A S1 30cd 1A-4,1V-4 2A CT-A 17 1D,1V,1A 3 (E)120V 1 PANEL WP S admin 161 154 2D SD ST president's office 162 admin 173 SD 153 L 168 admin 170 Room 174 REGIST 14 167 EE R GIN YA ER LE O 2A FESSIONA PRO L RD P. M A N A EN ED S 1A-5 IA WP S1 1A-6 275 W. Hospitality Lane Suite #100 San Bernardino, CA 92408 Phone: 909.890.3700 Fax: 909.890.3770 email: info@designwesteng.com FIRST FLOOR FIRE ALARM PLAN 1/8" = 1'-0" 1 DESIGN WEST ENGINEERING MECHANICAL ELECTRICAL ENERGY CONSULTANTS 3 MACARTHUR PLACE, SUITE 850 T 949.809.3380 SANTA ANA, CA 92707 WWW.SVA-ARCHITECTS.COM THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2014. 14-312