CALVIN COLLEGE ENGINEERING TEAM BI0DOR GRAND RAPIDS, MI WYOMING CLEAN WATER PLANT ODOR CONTROL 05/06/2016 Kent County Project Location SHEET INDEX Sheet No. Description ONE-CALL NOTIFICATION SYSTEM CALL BEFORE YOU DIG!!! 800-482-7171 CODE INFORMATION CODE USED : 2003 MICHIGAN BUILDING CODE GENERAL LIMITATIONS USE GROUP = U (UTILITY AND MISCELLANEOUS) PER PERSON (SIMILAR TO WAREHOUSE) = 94 PERSONS CONSTRUCTION TYPE 3B - NOT SPRINKLED GENERAL CONSTRUCTION NOTE ALL UTILITIES SHOWN ARE APPROXIMATE LOCATIONS DERIVED FROM ACTUAL MEASUREMENTS AND AVAILABLE RECORDS. THEY SHOULD NOT BE INTERPRETED TO BE THE EXACT LOCATION NOR SHOULD IT BE ASSUMED THAT THEY ARE THE ONLY UTILITIES IN THIS AREA. All elevations labeled according to Wyoming Clean Water Plant Datum Title Title 1 General Site Plan 2 Process Flow Diagram 3 Existing Aeration Basin Plan Sections 4 Proposed System Plan Views 5 Proposed Biofilter Cross Sections 6 Existing Fan Shop Drawings Enlarged Plan (NTS) Notes: 1. The splitter box will be enclosed by a concrete structure designed for easy maintenance access. 2. All proposed concrete will be cast-in-place with reinforcing rebar. 3. All exposed concrete will be installed with a protective epoxy coating to prevent corrosion. 4. Ductwork will be installed a minimum of 15' above ground for vehicle traffic. 5. Ductwork will be supported by structural columns where necessary. All other ductwork can be supported by the roof of existing buildings or installed along the side of the buildings. General Site Plan (Not To Scale) Wyoming Clean Water Plant Odor Control Preliminary Biofilter Design Reference Plans: Black & Veatch Clean Water Plant Stage 2 Improvements General Site Plan Project No. 69722 Plans Not For Construction Date: 05/06/2016 3201 Burton SE Grand Rapids, MI 49546 Sheet No. 1 of 6 Process Flow Diagram Wyoming Clean Water Plant Odor Control Preliminary Biofilter Design Plans Not For Construction Date: 05/06/2016 3201 Burton SE Grand Rapids, MI 49546 Sheet No. 2 of 6 Concrete Walkway 1E 3 Concrete Walkway Finished Grade El. 608' - 0" Concrete Walkway Finished Grade El. 608' - 0" 2E 3 Column Aeration Basin Pipe Gallery Existing Aeration Basin (Proposed Biofilter) El. 587' - 6" A EXISTING PLAN EL. 608' - 0" 1E EXISTING SECTION (refer to Plan View A, this sheet) SCALE: 1:100 El. 587' - 6" 2E EXISTING SECTION (refer to Plan View A, this sheet) SCALE: 1:100 SCALE: 1:100 Existing Aeration Basin Plan Sections Wyoming Clean Water Plant Odor Control Preliminary Biofilter Design Plans Not For Construction Date: 05/06/2016 3201 Burton SE Grand Rapids, MI 49546 Sheet No. 3 of 6 Irrigation Line: Connect to Effluent Water Source in Pipe Gallery Concrete Walkway Nutrient Supply Pipe Gallery Humidification Line: Connect to Effluent Water Source in Pipe Gallery Connect to Existing 16"Basin Drain Connect to Existing 16"Basin Drain Pipe Gallery Note: Concrete Walkway Extension not shown for clarity 6" Condensation Drainage Reducing T-Connection 30" Air Flow Duct Empty Aeration Basin 36" Air Flow Duct 30" Air Flow Duct Empty Aeration Basin Empty Aeration Basin BIOFILTER No. 1 BIOFILTER No. 2 1 5 2 5 4 5 A 3 5 PLAN EL. 611' - 6" SCALE: 1:100 Humidification Chamber Hatch Cover B PLAN EL. 603' - 7" SCALE: 1:100 Note: Biofilter Cover not shown for clarity C PLAN EL. 595' - 4" SCALE: 1:100 Proposed System Plan Views Wyoming Clean Water Plant Odor Control Preliminary Biofilter Design Plans Not For Construction Date: 05/06/2016 3201 Burton SE Grand Rapids, MI 49546 Sheet No. 4 of 6 Finished Grade El. 608' - 0" Pipe Gallery 4" Insulation El. 600' - 1" Irrigation Line: Connect to Effluent Water Source in Pipe Gallery Stainless Steel Grate Spray Nozzles 3' above media bed El. 595' - 4" Woodchip Media Finished Grade El. 608' - 0" Concrete Walkway El. 611' - 6" El. 609' - 8" 36" Air Duct Finished Grade El. 608' - 0" Existing Column Lava Rock Media Stainless Steel Grate Air Distribution Plenum El. 587' - 6" 42" Air Duct El. 603' - 7" 2 SECTION (See Sheet 4) SCALE: 1:100 El. 601' - 4" El. 611' - 6" El. 600' - 1" Stainless Steel Grate El. 609' - 8" Finished Ground El. 608' - 0" El. 603' - 7" Humidification Line: Connect to Effluent Water Source in Pipe Gallery 30" Air Duct Spray Nozzles 3' above media bed Pipe Gallery El. 595' - 4" 3' - 0" Woodchip Media 2' - 0" Lava Rock Media 6" Condensation Drainage Connect to Existing 16"Basin Drain Stainless Steel Grate Air Distribution Plenum Slight slope downward to allow for drainage 3 SECTION (See Sheet 4) SCALE: 1:100 Finished Grade El. 608' - 0" El. 588' - 3" Elbow 1" above ground to allow for drainage Grout Slope 12" per foot 42" Air Duct Outlet Fiberglass Reinforced Plastic Cover 1 6" Condensation Drainage Connect to Existing 16"Basin Drain SECTION (See Sheet 4) SCALE: 1:50 El. 600' - 1" Pipe Gallery Proposed Biofilter Cross Sections Fiberglass Access to Air Distribution Plenum Wyoming Clean Water Plant Odor Control Preliminary Biofilter Design El. 587' - 6" Plans Not For Construction 4 Date: 05/06/2016 SECTION (See Sheet 4) SCALE: 1:100 3201 Burton SE Grand Rapids, MI 49546 Sheet No. 5 of 6 8 6 7 5 4 24" 25 15/16" 1 DRAWING NOTES: 28" D 2 3 21" (INSIDE) 29" (INSIDE) 29 7/16" D 36" 28 1/2" (OUTSIDE) 43" 28 1/2" C C 33 13/16" ACCESSORY LIST (DISPLAYABLE) 14 5/16" DESCRIPTION 28" 26 3/8" 2" ACCESSORY LIST (NOT DISPLAYABLE) SEE ORDER ACKNOWLEDGEMENT FOR DETAILS QTY. ACCESS DOOR N/A GUARD(S) IN AIRSTREAM N/A DAMPER N/A HEIGHT ADJUSTING SUB BASE N/A DAMPER ACCESSORIES N/A INLET FLANGE N/A DRAIN WEATHER COVER N/A FRP COATING N/A FRP CONSTRUCTION N/A SPECIAL SHAFT SEAL 1 SPECIAL HARDWARE 1 B 14 13/16" 11/16" x 1 1/2" SLOT (QTY. 8) 29 5/8" QTY. DESCRIPTION 1 SPECIAL SHAFT N/A STARTERS & DISCONNECTS N/A VIBRATION ISOLATORS N/A B 14 13/16" MODEL NUMBER: A41P0-272FA100FGFCP3 UNLESS OTHERWISE SPECIFIED: 13 1/16" DIMENSIONS ARE IN INCHES 25 3/8" TOLERANCES: FRACTIONAL 1/8" ANGLES 1 A PROPS & WHEELS ARE NOT DRAWN AS BUILT AND ARE FOR REPRESENTATION ONLY. THE FAN MODELS AND ACCESSORIES ARE DIMENSIONALLY ACCURATE, BUT ARE NOT VISUALLY ACCURATE AS BUILT. 26 3/8" 34 3/8" DRAWING SCALE: BOTTOM VIEW 8 7 SCALED 6 5 4 FAN DESCRIPTION: Series 41P - Fiberglass Backward Curved Centrifugal Fan, Packaged, Type FA Hartzell Air Movement Piqua, Ohio 45356 1-800-336-3267 www.hartzell.com FAN TAG NUMBER: PROPOSAL NUMBER: Config-94617 00 HARTZELL SALES ORDER NUMBER: MODEL REV: 01 3 A REV PROPRIETARY AND CONFIDENTIAL ITEMS SHOWN ON THIS DRAWING ARE THE INTELLECTUAL PROPERTY OF HARTZELL AIR MOVEMENT AND ARE PROVIDED FOR INTERFACE DIMENSIONS ONLY. DRAWINGS AND PERFORMANCE DATA SHALL NOT BE COPIED OR RELEASED WITHOUT THE WRITTEN CONSENT OF HARTZELL AIR MOVEMENT AND SHALL BE RETURNED ON REQUEST. PAPER SIZE: DATE: 4/21/2016 2 B SHEET 1 OF 1 1