Concrete Inserts Fig. 109AF - Concrete Insert - Hanger Application (B-Line B2501) Size Range: 3/8"-16 thru 7/8"-9 rod Material: Steel Function: Designed to be embedded in concrete to provide a point of support. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) for 3/8" and 1/2". Finish: Electro-Galvanized anchor bolt with Electro-Galvanized hardware and plate. Order By: Figure number, rod size and finish. Concrete Inserts Note: The hex or jam nut has NO value in determining the loads. Their function is to assist in locking the coupling snug to the bottom of the deck form preventing the concrete from leaking into the coupling threads. Any other suitable locking device may be substituted if desired. Applications Per NFPA 13 (2010): UL Listed as a component of a hanger assembly per Section 9.1.1.4.1 See dimensions and installation Detail below. Anchor Bolt ASTM A307 E Rod Coupling Edge of Concrete Mounting Hole for Securing to Form DE Min. Design Load-Vertical Rod Size Part No. Max. Pipe Size (IPS) in. 109AF-3/8 3/8"-16 109AF-1/2 1/2"-13 109AF-5/8 5/8"-11 (mm) Embedment Depth E in. (mm) (100) 31/2” (88.9) 8 (200) 31/2” (88.9) 12 (300) 4” (101.6) 4 DE Min. in. (mm) Approx. Wt./100 Lbs. (kg) 2” (50.8) 38.1 (17.3) 2” (50.8) 54.7 (24.8) 2” (50.8) 82.2 (37.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 76 Fire Protection Solutions Concrete Inserts Fig. 109AF - Concrete Insert - Brace Application (B-Line B2501) Size Range: 3/8"-16 thru 7/8"-9 rod Material: Steel Function: Designed to be embedded in concrete to provide a point of support. Finish: Electro-Galvanized anchor bolt with Electro-Galvanized hardware and plate. Note: The hex or jam nut has NO value in determining the loads. Their function is to assist in locking the coupling snug to the bottom of the deck form preventing the concrete from leaking into the coupling threads. Any other suitable locking device may be substituted if desired. Anchor Bolt ASTM A307 Qualifies as an acceptable alternate seismic brace fastener per Section 9.3.5.9.6 Certification calculations for this application are available upon request. See dimensions and installation Detail below. E Rod Coupling Edge of Concrete Mounting Hole for Securing to Form Design Load 45° DE Min. Rod Size Part No. 109AF-3/8 109AF-1/2 109AF-1/2 109AF-5/8 109AF-5/8 109AF-3/4 109AF-3/4 109AF-7/8 109AF-7/8 3/8"-16 1/2"-13 1/2"-13 5/8"-11 5/8"-11 3/4"-10 3/4"-10 7/8"-9 7/8"-9 Max. Horizontal Seismic Load With Brace At 45° Embedment Depth E DE Min. Approx. Wt./100 in. (mm) in. (mm) in. (mm) Lbs. (kg) 925 925 950 1250 1424 1275 1424 1330 1424 (4.11) 31/2” 31/2” 4” 4” 5” 4” 6” 4” 7” (88.9) 2” 2” 2” 2” 2” 2” 2” 2” 2” (50.8) 38.1 54.7 54.7 82.2 82.2 113.8 113.8 130.6 130.6 (17.3) (4.11) (4.22) (5.56) (6.33) (5.67) (6.33) (5.91) (6.33) (88.9) (101.6) (101.6) (127.0) (101.6) (152.4) (101.6) (177.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (24.8) (24.8) (37.3) (37.3) (51.6) (51.6) (59.2) (59.2) Seismic bracing design load calculated in compliance with the requirements of IBC 2009 / CBC 2010. Rod Size Part No. 109AF-3/8 109AF-1/2 109AF-1/2 109AF-5/8 109AF-5/8 109AF-3/4 109AF-3/4 109AF-7/8 109AF-7/8 3/8"-16 1/2"-13 1/2"-13 5/8"-11 5/8"-11 3/4"-10 3/4"-10 7/8"-9 7/8"-9 Max. Horizontal Seismic Load With Brace At 45° Embedment Depth E DE Min. Approx. Wt./100 in. (mm) in. (mm) in. (mm) Lbs. (kg) 781 781 807 999 1275 1029 1424 1074 1424 (3.47) 31/2” 31/2” 4” 4” 5” 4” 6” 4” 7” (88.9) 2” 2” 2” 2” 2” 2” 2” 2” 2” (50.8) 38.1 54.7 54.7 82.2 82.2 113.8 113.8 130.6 130.6 (17.3) (3.47) (3.59) (4.44) (5.67) (4.57) (6.33) (4.78) (6.33) (88.9) (101.6) (101.6) (127.0) (101.6) (152.4) (101.6) (177.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (50.8) (24.8) (24.8) (37.3) (37.3) (51.6) (51.6) (59.2) (59.2) Seismic bracing design load calculated in compliance with the requirements of IBC 2012 / CBC 2013. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 77 Revised 8/8/2014 Concrete Inserts Order By: Figure number, rod size and finish.