INSTALLATION INSTRUCTIONS V90042 REV B QUIET CEILING INSULATED CEILING SQUARE TRIM QCT903, QCM512 BASED SERIES Page 1 of 2 Avoid Fire or Electric Shock THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. Joist Installation (Figure 3): Fixture Mounting: Hanger Bar Mounting (Residential): 1. 2. Adjustable hanger bars are preassembled with mounting bracket and provided with fixture.The preassembled hanger bars must attached to the fixture prior to installation.Align with two screws on end of fixture and tighten .Hanger bars are installed in Fig.1. Hanger bars can be used with grid ceilings having T bars and joist installations of wood.Adjustable hanger bars are for use in installations with spacing from 12" to 24", while maintaining minimum 1/2" spacing around fixture Step 1 Extend bar hangers to fit between joist and position mounting tab locater lip tight to bottom of joist or framing member. Bar hangers should be level with bottom of joist or framing member. Step 2 Attach bar hangers to joist or framing member using appropriate hardware for material. Step 3 Adjust housing platform position by sliding back and forth on bar hangers to desired position. Housing may be locked into position See Detail 3A.Nail Supplied in hanger bars will be suitable. Grid Ceiling Installation (Figure 2): Step 1 Extend bar hangers between the T bars and slide the slots in the mounting tabs over the T-bars. Step 2 Adjust housing platform position by sliding back and forth on bar hangers to desired position. Housing may be locked in the position by tightening bar hanger locking screws on housing platform.See Detail 2A. Optional "T" Screw Fixture Housing Cover Figure 2 Bracket Hanger Bar Detail 2A Mudding Frame Safety Cable Trim Mechanism Detail 3A Figure 1 Figure 3 INSTALLATION INSTRUCTIONS V90042 REV B QUIET CEILING INSULATED CEILING SQUARE TRIM QCT903, QCM512 BASED SERIES Page 2 of 2 Avoid Fire or Electric Shock THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. Rotational Adjustment Ring Lock Knob Mudding Frame Mudding Ring Fixture Window/Ceiling Thickness Mark 5/8" Mudding Frame Bracket Flathead Screw #8-32 Flat Head Screw Ceiling Drywall Tape Fixture Gap Mudding Compound Figure 5 Ball Detent Catch Trim Mechanism Figure 4 3. Mudding Ring is sent unmounted from factory. Adjust Mudding Ring to applicable Ceiling thickness by aligning and securing to Fixture using applicable Mounting Hole Pattern as indicated by Ceiling Thickness Indicator Mark imprinted on Mudding Ring. See Fig.5. 4. Secure Mudding Ring using four (4) #8-32 x 1/2 inch Flat head Screws (for 1/2 inch, 5/8 inch and 3/4 inch Ceiling thickness) or four (4) #8-32 x 3/4 inch Flat head Screws (for 1 inch Ceiling thickness). 5. Install Ceiling drywall up to Mudding Ring on Fixture so that the two (2) Mudding Frame Brackets contact inside of Ceiling. See Fig. 4. 6. Retain Fixture to Ceiling with one (1) Flathead Screw through each of two (2) Mudding Frame Brackets.See Fig.4. 7. Apply Drywall Tape and Mudding Compound to Mudding frame overlapping Mudding frame, Flathead Screws, Fixture Gap and surrounding area. Feather out Mudding Compound from Mudding Ring opening to surrounding ceiling area to produce a smooth, flat finish. See Fig. 4. Trim Installation: 8. Connect Safety Cable attached to Trim to Fixture by inserting Safety Cable through opening in Fixture and inserting Snap Hook (See Fig. 1) on end of Safety Cable into hole in Bracket attached to inside of fixture. 9. Install Trim Mechanism into fixture by pressing firmly to seat ball detent catches. See Fig.4.