D es c r iption
The New ArcDuo Retrofit Kit is an effective “Energy Savings Alternative”
for today’s environmentally conscious marketplace. This retrofit kit
system provides customers the opportunity to upgrade their dated louver
or lens to a more contemporary lens shielding that is highly efficient and
quick to install, without the added renovation and disposal costs. The
architectural retrofit kit is designed for installation into a 2' x 4' parabolic
or troffer.
In a marketplace where aesthetics are still critical elements used to
convey style, appearance and performance, the ArcDuo Retrofit Kit is the
smart solution for any office, government, educational and retail retrofit
kit application whose goal involves energy awareness and conservation.
®
Type
Catalog #
Project
Date
Comments
Prepared by
Spe c ific a tion F ea t u r e s
C on s t r u c t i o n
The retrofit kit assembly consists
of four components and fits into
most parabolics and troffers.
Universal brackets are made from
code gauge steel and come prewired to ballast and sockets. Kits
are pre-assembled and ready for
quick, easy install right out of the
box. A one-piece high reflectance
white reflector installs without
any hardware, while a die formed
doorframe and architectural
lens shielding provides the last
component of this retrofit system.
Minimum housing depth = 3-1/2"
Ready-Set
Pre-installed self-tapping screws
easily penetrates existing fixture
body and ends. Leveling flange
aligns, supports, and holds
hardware in place, letting you hold
the brackets with one hand while
driving in screws. No parts bag or
extra hardware needed.
Ele ctrica l*
Standard Class “P” electronic
ballast with captive hardware
for ease of install. Push-in
lampholders. UL/cUL Listed.
Suitable for damp locations. No
junction box required.
H inge/Latch
Positive spring loaded, self locking,
steel latching allows for easy
opening and closing of louver or
other shielding media. Hinging and
latching can be done from either
side of the retrofit kit for increased
installation flexibility and ease of
maintenance.
Optics
Do o r Fin ish
Cold rolled steel w/multistage
iron phosphate pre-treatment
for maximum bonding. Highly
reflective matte white finish on all
reflective surfaces for increased
efficiency.
Die formed doorframe and
architectural lens shielding
provides a modern architectural
appearance similar to the
Metalux accord. Lens overall
optical efficiency is above 84%.
Optional 97% reflective White
Optics material is available to help
further maximize kit efficiency,
distribution, energy savings
and payback.
ArcDuo
Retrofit 2x4
232, 228T5
254T5
2 Lamp Troffer and
Parabolic Architectural
Retrofit Kit
Patent Pending
13-1/2" [342mm]
3-1/2"
[89mm]
10-3/4" [274mm]
Ret r ofit C om pa tib i l i t y
The ArcDuo retrofit kit was designed to upgrade troffer or parabolic fixtures from all major
manufacturers that have the following minimum dimensions:
12-1/4" [311mm]
CROSS SECTION
5/8" [16mm]
3-1/2"
[89mm]
Energy Data
22-7/16" [569mm]
23-3/4" [603mm]
Nominal
47-15/16" [1218mm]
47-29/32" [1217mm] Min. End to End
45-3/8" [1153mm] Min. Inside
46-1/2" [1181mm] Min. Inside Opening
Input Watts:
EB Ballast & STD Lamps
228T8=47
232=55
T5 Ballast & STD Lamps
228T5=62
254T5=117
47-3/4" [1213mm] Nom. Overall Length
Before ordering refer to these dimensions as a reference or contact your local representative for a
trial install prior to ordering large job quantities.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF101607
2014-05-01 15:35:26
A r cD u o R e t r ofit 2 x4
Photom etr ic s
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
ART-2ARC-232L
Electronic Ballast
(2) 32W T8 lamps
2850 lumens.
Spacing criterion:
(II ) 1.2 x mounting
height, ( ) 1.3 x
mounting height.
Efficiency = 83.8%.
Test Report:
ART-2ARC-232L.IES
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
100
91
83
75
69
63
58
54
50
47
44
93
82
71
63
56
50
45
41
37
34
32
89
78
69
60
54
48
43
40
36
33
31
86
75
66
58
52
47
42
38
35
33
30
84
70
58
49
42
36
31
28
25
22
20
100
87
76
67
59
53
47
43
39
36
33
100
84
70
60
51
45
40
35
32
29
26
100
80
65
54
46
39
34
30
27
24
22
97
89
81
73
67
62
57
53
49
46
43
97
85
74
65
58
52
46
42
38
35
33
97
82
69
59
51
44
39
35
32
29
26
97
79
65
54
45
39
34
30
27
24
22
93
79
67
57
50
43
39
34
31
28
26
93
77
63
53
45
39
34
30
27
24
22
89
76
65
56
48
43
38
34
31
28
25
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
In Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
1282
2111
3781
4779
4779
22.5
37.0
66.3
83.8
83.8
26.8
44.2
79.1
100.0
100.0
89
74
62
52
44
38
33
30
26
24
22
Average
0-Deg
cd/sm
2567
2524
2409
2173
1656
86
74
63
54
47
42
37
33
30
27
25
Average
45-Deg
cd/sm
2625
2561
2351
1939
1054
86
72
60
51
44
38
33
29
26
24
21
Average
90-Deg
cd/sm
2681
2550
2250
1793
753
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1643
1626
1601
1563
1514
1451
1378
1297
1206
1107
998
883
757
621
482
343
208
88
0
45°
1643
1634
1613
1580
1535
1476
1406
1325
1234
1132
1018
896
758
606
454
306
171
56
0
Across
1643
1638
1621
1593
1553
1496
1429
1352
1261
1156
1035
892
737
580
425
283
149
40
0
LER = FL-79
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.04
Photom etr ic s
C o e f fi c i e n t s o f U t i l i z a t i o n
ART-2ARC-WO-232L
Electronic Ballast
(2) 32W T8 lamps
2850 lumens.
Spacing criterion:
(II ) 1.3 x mounting
height, ( ) 1.3 x
mounting height.
Efficiency = 88%.
Test Report:
ART-2ARC-WO-232L.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
105
96
87
79
72
67
61
57
53
49
46
98
86
75
66
58
52
47
43
39
36
33
94
82
72
63
56
51
46
42
38
35
32
90
79
69
61
54
49
44
40
37
34
32
88
74
61
51
44
38
33
29
26
23
21
105
92
80
70
62
55
50
45
41
38
35
105
88
74
63
54
47
42
37
33
30
28
105
84
69
57
48
41
36
32
28
25
23
102
93
85
77
70
65
60
55
52
48
45
102
90
78
68
61
54
49
44
40
37
34
102 102
86 83
72 68
62 56
53 48
47 41
41 36
37 32
33 28
30 25
27 23
98
83
70
60
52
46
40
36
33
30
27
98
80
66
55
47
41
35
31
28
25
23
94
80
68
58
51
45
40
36
32
29
27
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
In Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
1345
2216
3965
5017
5017
23.6
38.9
69.6
88.0
88.0
26.8
44.2
79.0
100.0
100.0
Average
0-Deg
cd/sm
2697
2656
2557
2325
1844
94
78
65
54
46
40
35
31
28
25
23
90
77
66
57
50
44
39
35
32
29
26
Average
45-Deg
cd/sm
2757
2684
2464
2046
1185
90
76
63
53
46
40
35
31
28
25
23
Average
90-Deg
cd/sm
2801
2641
2336
1869
828
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1723
1708
1681
1641
1589
1524
1449
1363
1268
1163
1051
929
799
659
513
367
225
98
6
45°
1723
1715
1693
1658
1611
1550
1478
1392
1296
1189
1071
939
793
635
477
323
183
63
5
Across
1723
1719
1701
1670
1628
1570
1498
1417
1321
1208
1078
924
765
602
443
295
156
44
1
LER = FL-82
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.93
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
ADF101607
2014-05-01 15:35:26
A r cD u o R e t r ofit 2 x4
Order in g I nfor m a tion
SAMPLE NUMBER: ART-2ARC-232L-UNV-EB81-10B
Product
ART=Advanced
Retrofit
Technology
Width
2=2' Nominal
Series
ARC=ArcDuo
Retrofit Kit
Number of
Lamps
2=2 lamps
(Not Included)
Wattage (Length)
32=32W T8 (48")
28T5=28W T5 (48")
254T5=54W T5HO (48")
Distribution
Blank=White
(Medium)
WO=White
Optics
(General)
Ballast Type
T5 Ballasts
EBT =T5 or T5HO Electronic
Program Rapid Start.
Total Harmonic Distortion
< 10%. Standard Ballast
Factor=1.0
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (2)
NB=No Ballast
Ballast/FactorType
Emergency Option
EL=Emergency
Installed. Low Profile
Battery Pack Only.
(consult factory)
Shielding
L=Acrylic Lens
Shield (Standard)
Packaging
10B=Bulk Pack
U=Unit Pack
(Consult factory for
other packaging
options)
EBT N=T5 Electronic
Program Rapid Start.
Total Harmonic Distortion
< 10%. Normal Ballast
Factor=.90
EBT H=T5 Electronic
Program Rapid Start.
Total Harmonic Distortion
< 10%. High Ballast
Factor=1.15
T8 Ballasts
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Start.
Total Harmonic
Distortion < 10%.
High Ballast Factor > 1.15
ER8 =T8 Electronic Program
Rapid Start. Total Harmonic
Distortion < 10%
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Standard Ballast
Factor .86 – .88
HB8 L=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Low Ballast Factor
.77 – .82
HB8 N=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Normal Ballast Factor
1.0
HB8 H=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Normal Ballast Factor
1.15 – 1.20
HR8 T8 Electronic Program Rapid (3)
Start. Total Harmonic
Distortion < 10%. Standard
Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program (3)
Rapid Start. Total
Harmonic Distortion <
10%. Step Dimming.
Ballast Factor .88
HR8 L=T8 Electronic Program (3)
Rapid Start. Total Harmonic
Distortion < 10%. Low
Ballast Factor .71 – .79
HR8 H=T8 Electronic Program (3)
Rapid Start. Total Harmonic
Distortion < 10%. High
Ballast Factor 1.15 – 1.20
Number of Ballasts
1=1 Ballast
2=2 Ballasts
[Blank]=No Ballast (NB Option Only)
(1)
NOTES: Products also available in non-US voltages and frequencies for international markets.
motion sensor, daylight harvesting or similar controls.
(2)
Not available when specifying emergencies, voltage must be specific.
(3)
Recommended when using retrofits together with
For complete product data, go to www.metalux-lighting.com. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
ADF101607
2014-05-01 15:35:26
Download