Metalux D ES C R IPTION Type Catalog # ArcLine is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest lamp and micro electronic ballast technology for optimal performance and energy efficiency. The ArcLine is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Project Date Comments Prepared by The ArcLine series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l H inging/Latching Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Gridlock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor lock lampholders. UL/CUL listed. Suitable for damp locations.** Positive cam action steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Door assembly hinges down for easy access from below without tools. F in ish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. Frame/Shielding Die formed, heavy gauge, flat steel door with reinforced mitered corners and paint after fabrication, baked matte white enamel finish. Positive light seals. Light stabilized, acrylic frosted lens. 2ALN 328T8 332 2' X 4' TROFFER 3 T8 LAMPS Specification Architectural Troffer 3-1/4" [83mm] For Use In Insulated Ceilings 23-3/4" [603mm] MOUNTING D A TA D OOR F RA ME S ALN Flat, White Steel 47-15/16" [1218mm] ENERGY DATA 23-3/4" [603mm] Input Watts: EB Ballast & STD Lamps 328T8 (66), 332 (80) L A MP CONF IGURA T IONS 3-1/4" [83mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ****When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. 23-3/4" [603mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid G G G (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF122021 2015-06-09 11:42:23 2 ALN T 8 PH OTOM ETR IC S 90˚ 75˚ 900 60˚ 1800 45˚ 2700 0˚ 15˚ 30˚ 2ALNG-332-UNVEB81-U Electronic Ballast (3) F32T8 Lamps 2950 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 84.7% Lumens: 7494 LER = FL77 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.12 Test Report: 2ALNG-332-UNVEB81-U.IES Candlepower Along II 2571 2567 2524 2463 2368 2251 2106 1944 1777 1583 1388 1192 990 794 605 418 255 110 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 45° 2571 2561 2529 2476 2398 2303 2191 2055 1901 1735 1550 1356 1151 942 744 547 361 170 0 Across ⊥ 2571 2573 2550 2504 2449 2373 2274 2160 2024 1858 1676 1478 1274 1053 838 627 409 170 0 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 92 83 76 69 64 59 55 51 47 44 101 88 76 67 59 53 47 43 39 36 33 101 101 84 81 70 65 60 54 52 46 45 39 40 34 35 30 32 27 29 24 26 22 98 89 81 74 67 62 57 53 49 46 43 98 86 75 65 58 52 47 42 39 35 33 98 82 69 59 51 45 39 35 32 29 26 98 79 65 54 45 39 34 30 27 24 22 20% 50% 50 30 10 30% 50 30 10 50 94 82 72 63 56 50 45 41 37 34 32 90 79 69 61 54 48 44 40 36 34 31 86 76 66 58 52 47 42 39 35 33 30 94 79 67 57 50 44 39 35 31 28 26 94 77 63 53 45 39 34 30 27 24 22 90 76 65 56 48 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2008 3294 5830 7494 7494 %Lamp 22.7 37.2 65.9 84.7 84.7 %Fixture 26.8 43.9 77.8 100.0 100.0 Average 0-Deg cd/sm 3294 3044 2752 2389 1854 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 90 74 62 52 44 38 33 30 27 24 22 10% 30 10 Average 45-Deg cd/sm 3592 3443 3276 3068 2499 86 74 63 54 47 42 37 33 30 28 25 86 72 60 51 44 38 33 29 26 24 22 0% 0 85 70 58 49 42 36 31 28 25 22 20 Average 90-Deg cd/sm 3901 3853 3758 3774 2701 Specifications and dimensions subject to change without notice. ADF122021 2015-06-09 11:42:23 2 ALN T 8 ORDER ING INFOR M A TION SAMPLE NUMBER: 2ALNG-332-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Series ALN=ArcLine Series Number of Lamps 3=3 Lamps Voltage (2) 347V=347 Volt UNV=Universal Voltage 120-277 (3) Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed (see options and accessories) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (4) (Not included) Shielding Blank=Smooth Frosted Acrylic (standard) Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid Door Frame Standard=Flat White Steel Door (Leave Blank) (1) (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Products also available in non-US voltages and (3) (4) frequencies for international markets. Not available when specifying emergencies, voltage must be specific. Non-integral (5) solution only, must specify voltage. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type (2) EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballast (HPT8) HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options G1=Gasket, Door Frame and Housing (Standard) G2=G1 plus Gasket between Lens and Door G3=G1 and G2 plus Gasketing on Mounting Surface of Fixture Trims Packaging U=Unit Pack PALC=Job Pack, in carton Fifthlight Ballasts (5) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) DF-24-W=2' x 4' Drywall Flange Kit SH IP P ING D ATA Catalog No. 2ALNG-328T8 2ALNG-332 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 20 lbs. 20 lbs. ADF122021 2015-06-09 11:42:23