Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer The marketplace a parabolic choice when economics and shallow plenum space are factors. the Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Deep V center ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. P2GAX2024 2U1-5/8 2BX40 9, 12, 16 or 20 Cell 4-5/8" [117mm] 20" X 24" PARABOLIC 2 LAMP SEMI-SPECULAR LOUVER Paralux II Recessed Air Supply Troffer 19-3/4" [502mm] ENERGY DATA MOUNTING D A TA 7/8" [22mm] K.O. (2) Input Watts: EB Ballast & STD Lamps 2U1-5/8 (61) 2BX40 (67) L AM P CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 4-5/8" [117mm] 2" [51mm] 1-1/2" [38mm] 4-5/8" [117mm] 8-1/2" [216mm] 19-3/4" [502mm] 2" [51mm] 8-1/2" [216mm] 19-3/4" [502mm] 19-3/4" [502mm] 4-5/8" [117mm] 5-1/4" [133mm] 3-3/4" [95mm] 2" [51mm] 4-5/8" [117mm] 8-1/2" [216mm] 19-3/4" [502mm] 2" [51mm] 8-1/2" [216mm] 19-3/4" [502mm] 7-23/32" [196mm] **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. CEI LING C OM PA TIB I L I T Y T Concealed T Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.00 *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. 24" [610mm] G Grid/Lay-in Standard Luminaire Efficacy Rating LER = FP-60 Catalog Number: P2GAX2024-2U1-5/8 T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ (Verify compatibility/ consult Pre Sales Technical Support.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020597 2015-10-13 16:05:51 P 2 GAX2 0 2 4 2 L PH OTOM ETR IC S Coefficients of Utilization ⊥ || P2GAX20242U15/8S33I Electronic Ballast FBO31/35K Lamps 2750 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 67% Test Report: rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 80 74 69 63 58 53 49 45 41 38 35 80 72 64 57 51 45 40 36 32 29 26 80 69 60 53 46 50 35 31 27 24 21 80 67 57 49 42 36 31 27 23 20 17 78 71 67 65 57 52 48 44 40 37 34 78 70 63 56 50 45 40 36 32 29 26 78 68 59 52 46 39 34 30 27 23 21 78 66 56 48 42 35 31 27 23 20 17 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 74 67 60 54 49 43 39 35 31 28 25 71 65 59 53 47 42 35 34 30 27 25 68 63 57 51 46 41 37 33 29 26 24 67 59 51 45 39 33 29 25 21 18 16 74 66 58 51 44 39 34 30 26 23 20 74 64 55 48 41 35 30 26 23 20 17 71 63 56 50 43 38 33 29 26 23 20 71 62 54 47 41 35 30 26 23 19 17 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1055 1762 3202 3648 3648 19.4 32.4 58.8 67.0 67.0 28.9 48.3 87.8 100.0 100.0 Height Along 8.5’ 10.0’ 55 53 64 58 68 63 71 65 74 69 68 61 55 48 43 37 33 29 25 22 20 68 60 53 46 40 34 30 26 22 19 17 Height Across 8.5’ 10.0’ 54 51 63 57 68 62 70 64 74 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II Across⊥ 45° 1356 1351 1329 1293 1246 1190 1124 1356 1350 1329 1292 1244 1194 1158 1356 1357 1335 1335 1271 1278 1286 1049 960 861 749 632 498 337 158 41 18 7 0 1129 1075 989 898 780 626 419 177 43 16 5 0 1245 1208 1135 1014 908 685 376 122 44 19 5 0 68 P2GX20242U158S33IPAF.IES LER = FP-60 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.00 OR D ER ING INFOR M A TION SAMPLE NUMBER: P2GAX2024-2U1-5/8S33I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Series P2=Paralux II Trim Type (2) G=Grid/Lay-in (Standard) G or T=Concealed T/Slot Grid (3) F=Aluminum Flange Trim (6) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Width 2024=20" Width x 24" Length Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 2=2 Lamps Wattage U15/8=31W T8 (24") U6T8=31W T8 (24") 17=17W T8 (24") BX40=40W Biax (24") Louver Color S=Silver W=White Cell Configuration 33=3 Rows of 3, 9 Cell 34=3 Rows of 4, 12 Cell 44=4 Rows of 4, 16 Cell 45=4 Rows of 5, 20 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) Emergency=EM Installed Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% High Ballast Factor >1.15 No. of Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB5 =T5 Biax Electronic Instant Start. (7) Total Harmonic Distortion < 20% No. of Ballast 1 or 2 TEB5 =T5 Biax Electronic Instant Start. (7) Total Harmonic Distortion < 10% No. of Ballast 1 or 2 ER5 =T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. Convertibility applies to housing only, appropriate shielding media assemblies must be (3) (4) utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also (5) (6) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. Specify row configu(7) ration, type in catalog number when ordering complete fixture. Not available in UNV voltages. Must specify voltage. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(3) SH IP P ING D A T A Catalog No. P2GAX20X24-2BX40S33I P2GAX20X24-2U1-5/8S33I P2GAX20X24-2BX40S34I P2GAX20X24-2U1-5/8S34I P2GAX20X24-2BX40S44I P2GAX20X24-2U1-5/8S44I P2GAX20X24-2BX40S45I P2GAX20X24-2U1-5/8S45I Wt. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. ADF020597 2015-10-13 16:05:51