The 2HP is an energy saving solution for a multitude of applications. It
uses a high performance T8 system that can save up to 40% of energy
costs when compared to standard 3-lamp, 18-cell parabolics. The 2HP
incorporates a 2" precision formed louver into a 97% deep reflective
housing. This combination creates a soft, even distribution while
delivering a highly efficient T8 luminaire. The luminaire is compatible
with all of today’s popular ceiling systems and is available with a number
of options and accessories for increased application versatility. The
2HP series is an excellent choice for commercial office spaces, schools,
hospitals or retail merchandising areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
Louver
Die formed nominal 4-3/4" deep
paracontoured housing made
from code gauge, cold rolled
steel. Housing features die formed
stiffeners for added rigidity along
with end plates that securely attach
to housing via interlocking tabs.
Other housing features include a
Grid to T-option (or vice versa) that
allows you to do a conversion in
the field. End plates also have an
integral Grid-Lock feature for safety
and convenience. A contoured
ballast/wireway cover rests in the
center of the housing and can be
easily removed without tools, while
die formed captive lamp holders
encloses lampholder wiring for
easy lampholder replacement.
Ballasts are CBM/ETL Class “P” are
positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Die formed high reflectance white
aluminum (standard). Silver with
semi-specular finish (optional).
Accurate precision parabolic cells
are held in place by interlocking
feature. True-cut mitered corners.
Black reveal with mechanical
light seal around entire perimeter
of louver. Louver protected by
polyethylene cover.
Wh ite Op tics
97% reflective White Optics
material with matching PAF ballast
cover to help maximize retrofit
kit efficiency, distribution, energy
savings and payback.
Hin g in g /L a tch ing
Positive cam action spring loaded,
self locking, black steel latches with
safety lock T-hinges allow hinging
and latching from either side.
Controls
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energy-saving
products like occupancy sensors,
daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
2HP2GX
217
317
2U1-5/8
3U1-5/8
6, 9 Cell
4-3/4"
[121mm]
2' X 2' PARABOLIC
2 OR 3 LAMP
High Performance T8
23-3/4"
[603mm]
MOUNTING D A TA
2 LAMP
7/8" [22mm]
K.O. (2)
L A MP CONF IGURA T IONS
Access Plate
7/8" [22mm] K.O. (2)
3 LAMP
7/8" [22mm]
K.O. (4)
Access Plate
7/8" [22mm] (2)
2 LAMP – 6 CELL
4-3/4"
[121mm]
2"
[51mm]
10-3/16"
[259mm]
23-3/4" [603mm]
23-3/4"
[603mm]
23-3/4"
[603mm]
3 LAMP – 9 CELL
4-3/4"
[121mm]
3-5/8" [93mm]
1-3/4" [45mm]
6-7/8" [176mm]
24" [608mm]
3-5/8" [93mm]
1-3/4" [45mm]
2"
[51mm]
6-7/8" [176mm]
7"
7"
[178mm] [178mm]
23-3/4" [603mm]
24" [608mm]
C EILING C OM PA TIB IL I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
ENERGY DATA
Input Watts:
HB Ballast & STD Lamps
217 (31), 317 (45), 2U1-5/8 (54),
3U1-5/8 (81)
Luminaire Efficacy Rating
LER = FP-77
Catalog Number: 2HP2GX-WO217W23P
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.12
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
(Verify compatibility/ consult
factory.)
Safe and convenient means of
disconnecting power.
ADF101721
2015-11-03 12:37:09
2 H P 2 GX-W O 2 1 7
PH OTOM ETR IC S
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
2HP2-WO-2U158W23P
Electronic Ballast
FB051/31K lamps
2775 lumens.
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height.
Efficiency = 78.4%
Test Report:
2HP2-WO-2U158W23P
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
30%
50 30 10
10%
50 30 10
0%
0
93
86
78
72
66
61
93
82
72
64
57
51
93
79
67
58
50
44
93
76
63
53
45
39
91
84
76
70
64
59
91
81
71
62
56
50
91
78
66
57
49
43
91
75
62
52
45
39
87
77
68
60
54
48
87
75
64
55
48
42
87
73
61
51
44
38
83
74
65
58
52
47
83
72
62
54
47
42
83
70
59
50
43
38
80
71
63
56
50
45
80
70
60
53
46
41
80
68
58
50
43
37
78
67
56
48
41
36
56
52
48
45
42
46
41
38
35
32
39
35
31
28
26
34
30
27
24
22
54
50
47
44
41
45
41
37
34
32
38
34
31
28
26
34
30
27
24
22
44
40
36
33
31
38
34
31
28
25
33
30
26
24
22
42
38
35
32
30
37
33
30
27
25
33
29
26
24
22
41
37
34
32
29
36
33
30
27
25
33
29
26
24
21
31
28
25
22
20
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
20%
50%
50 30 10
Luminance Data
Lumens
%Lamp
%Fixture
1254
2066
3636
4352
0
4352
22.6
37.2
65.5
78.4
0.0
78.4
28.8
47.5
83.5
100.0
0.0
100.0
Angle
In Deg
45
55
65
75
85
Average
0-Deg
cd/sm
4601
4098
3276
Average
45-Deg
cd/sm
5456
5090
3932
Average
90-Deg
cd/sm
6375
5752
3575
2172
1895
2525
2137
3977
2378
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1614
1598
1558
1502
1433
1349
1256
1154
1045
926
800
669
532
394
266
160
100
47
1
45°
1614
1603
1579
1542
1496
1439
1370
1290
1200
1098
975
831
656
473
295
186
113
53
3
Across
1614
1609
1599
1588
1571
1542
1504
1455
1383
1283
1121
939
665
430
318
293
125
59
1
LER = FP77
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.12
Coefficients of Utilization
2HP2-WO-3U158S33I
Electronic Ballast
FB051/31K lamps
2775 lumens.
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height.
Efficiency = 69.1%
Test Report:
2HP2-WO-3U158S33I
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
82
76
70
64
59
55
51
47
44
41
39
82
73
64
57
51
46
42
38
35
32
30
82
70
60
52
46
40
36
32
29
27
24
82
68
57
48
41
36
32
28
25
23
21
80
74
68
62
57
53
49
46
43
40
38
80
71
63
56
50
45
41
38
34
32
29
80
69
59
51
45
40
36
32
29
27
24
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-180
0-180
Candela
Lumens
%Lamp
%Fixture
1896
3040
4918
5755
0
5755
22.8
36.5
59.1
69.1
0.0
69.1
32.9
52.8
85.5
100.0
0.0
100.0
80
67
56
48
41
36
32
28
25
23
21
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
77
68
61
54
49
44
40
37
34
31
29
74
66
59
52
47
43
39
36
33
30
28
71
63
57
51
46
41
38
35
32
30
27
69
59
51
44
38
33
29
26
24
21
19
77
66
57
50
44
39
35
32
29
26
24
77
65
55
47
40
35
31
28
25
23
21
74
64
56
49
43
38
34
31
28
26
24
74
63
53
46
40
35
31
28
25
23
21
71
62
54
48
42
38
34
31
28
26
24
71
61
52
45
39
35
31
28
25
23
21
Luminance Data
Angle
In Deg
45
55
65
75
85
Average
0-Deg
cd/sm
6643
5740
4306
3244
2782
Average
45-Deg
cd/sm
7011
5703
3874
3434
2782
Average
90-Deg
cd/sm
7011
4655
3974
3760
2903
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2474
2444
2370
2270
2153
2016
1863
1699
1523
1337
1138
937
729
518
337
239
149
69
5
45°
2474
2451
2412
2357
2280
2172
2032
1855
1645
1411
1161
931
683
466
351
253
156
69
3
Across
2474
2466
2468
2458
2407
2301
2132
1914
1653
1411
1115
760
559
478
391
277
168
72
1
LER = FP75
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.20
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADF101721
2015-11-03 12:37:09
2 H P 2 GX-W O 2 1 7
ORDER IN INFOR M A TION
Sample Number: 2HP2GX-WO-217W23P-UNV-HB81H-U
Cell
Configuration
23 =2 Rows of 3, 6
Cell (2'x2')
Rating
Blank =Standard
ATW-SW4 =Chicago
Rated
Heat Removal
HR =Heat Removal
33 =3 Rows of 3, 9
Cell (2'x2')
1
Louver Finish
I =SemiSpecular/Haze
(Low Iridescent)
(Silver Only)
Width
2 =2' Width
Series
HP2 =High
Performance
2" Paralux
Louver
P =Painted White
(Standard)
Option Aluminum Flange
Trim
Blank =SW (Single
White)
Trim Type
G =Grid/Lay-in Standard
G=Concealed T / Slot
Grid
F =Aluminum Flange
Trim
4
SN =Single, Natural Finish
RN =In Row, Natural
Finish
2
4
RW =In Row, White Finish
EN =End of Row, Natural
Finish
MZ =Modular Trim
EW =End of Row, White
Finish
Air Supply
AX =Air Supply
Floating Louver
Voltage 5
120V =120 Volt
X =Blank
Side/Floating
Louver - Non Air
Supply
277V =277 Volt
347V =347 Volt
AVX =Air Supply
Floating
Louver
w/Directional
Air Vane
UNV =Universal
Voltage
120-277
0-10V Dimming Ballasts 11
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87 14
6
5LTVS8 =T8 0-10V Spec Grade Program
Rapid Start. Total Harmonic
Distortion < 10%.
Ballast Factor 0.87 12, 13
Fifth Light DALI Ballasts 9
Options
GL =Single Element Fuse
White Optics
WO =97% Reflective
White Optics Finish
GM =Double Element
Fuse
5LT8 = T8 DALI Program Rapid Start.
Total Harmonic Distortion <
10%. Ballast Factor 1.0
WTR =White Reveal
Lamps =Lamps Installed
(refer to lamp
ordering
Number of
Lamps
2 =2 Lamps
3 =3 Lamps
Wattage
U15/8 =31W T8 (24")
10
EL =Emergency Installed
17 =17W T8 (24")
Louver Color
S =Silver
2 = 2 Ballast
7
Options
REP =Riveted End Plates
Packaging
U = Unit Pack
W=White
Notes: 1
Number of Ballasts
1 = 1 Ballast
Flex =Flex Installed
(Reference Flex
ordering
information)
8
Ballast Type
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Standard Ballast
Factor .86 – .88
HB8 L=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Low Ballast Factor
.77 – .82
HB8 N=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. Normal Ballast Factor
1.0
HB8 H=T8 Electronic Instant Start.
Total Harmonic Distortion <
10%. High Ballast Factor
1.15 – 1.20
HR8 T8 Electronic Program Rapid
Start. Total Harmonic
Distortion < 10%. Standard
Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program
Rapid Start. Total
Harmonic Distortion <
10%. Step Dimming.
Ballast Factor .88
HR8 L=T8 Electronic Program
Rapid Start. Total Harmonic
Distortion < 10%. Low
Ballast Factor .71 – .79
HR8 H=T8 Electronic Program
Rapid Start. Total Harmonic
Distortion < 10%. High
Ballast Factor 1.15 – 1.20
PAL= Job Pack, out of carton
PALC = Job Pack, in carton
Integral End Plate Grid Lock feature not available in Heat Removal
2
Louver is recessed by 5/16" in Concealed T or Slot Grid T.
3
An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
4
Specify row configuration, type in catalog number when ordering complete fixtures.
5
Products also available in non-US voltage and frequencies for international markets
6
Not available when specifying emergencies, voltage must be specific
7
Fixtures equipped with "EL" option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack.
8
Standard off-center ballast on 3-lamp fixtures.
9
For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(3)
10 Fifthlight ballast option not available.
11 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system.
12 Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.
13 Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions.
14 Standard 0-10V ballast not offered in 3 or 4-lamp versions
SH IP P ING D A T A
Catalog No.
2HP2GAX-WO-217W23P
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Wt.
28 lbs.
ADF101721
2015-11-03 12:37:09