Metalux D ES C R IPTION The 2HP is an energy saving solution for a multitude of applications. It uses a high performance T8 system that can save up to 40% of energy costs when compared to standard 3-lamp, 18-cell parabolics. The 2HP incorporates a 2" precision formed louver into a 97% deep reflective housing. This combination creates a soft, even distribution while delivering a highly efficient T8 luminaire. The luminaire is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for increased application versatility. The 2HP series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * Louver Die formed nominal 4-3/4" deep paracontoured housing made from code gauge, cold rolled steel. Housing features die formed stiffeners for added rigidity along with end plates that securely attach to housing via interlocking tabs. Other housing features include a Grid to T-option (or vice versa) that allows you to do a conversion in the field. End plates also have an integral Grid-Lock feature for safety and convenience. A contoured ballast/wireway cover rests in the center of the housing and can be easily removed without tools, while die formed captive lamp holders encloses lampholder wiring for easy lampholder replacement. Ballasts are CBM/ETL Class “P” are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Die formed high reflectance white aluminum (standard). Silver with semi-specular finish (optional). Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. Wh ite Op tics 97% reflective White Optics material with matching PAF ballast cover to help maximize retrofit kit efficiency, distribution, energy savings and payback. Hin g in g /L a tch ing Positive cam action spring loaded, self locking, black steel latches with safety lock T-hinges allow hinging and latching from either side. Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2HP2GX 217 317 2U1-5/8 3U1-5/8 6, 9 Cell 4-3/4" [121mm] 2' X 2' PARABOLIC 2 OR 3 LAMP High Performance T8 23-3/4" [603mm] MOUNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 3 LAMP 7/8" [22mm] K.O. (4) Access Plate 7/8" [22mm] (2) 2 LAMP – 6 CELL 4-3/4" [121mm] 2" [51mm] 10-3/16" [259mm] 23-3/4" [603mm] 23-3/4" [603mm] 23-3/4" [603mm] 3 LAMP – 9 CELL 4-3/4" [121mm] 3-5/8" [93mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] 3-5/8" [93mm] 1-3/4" [45mm] 2" [51mm] 6-7/8" [176mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] 24" [608mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ ENERGY DATA Input Watts: HB Ballast & STD Lamps 217 (31), 317 (45), 2U1-5/8 (54), 3U1-5/8 (81) Luminaire Efficacy Rating LER = FP-77 Catalog Number: 2HP2GX-WO217W23P Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.12 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult factory.) Safe and convenient means of disconnecting power. ADF101721 2015-11-03 12:37:09 2 H P 2 GX-W O 2 1 7 PH OTOM ETR IC S Coefficients of Utilization rc rw RCR 0 1 2 3 4 2HP2-WO-2U158W23P Electronic Ballast FB051/31K lamps 2775 lumens. Spacing criterion: (II) 1.2 x mounting height, ( ) 1.4 x mounting height. Efficiency = 78.4% Test Report: 2HP2-WO-2U158W23P 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 93 86 78 72 66 61 93 82 72 64 57 51 93 79 67 58 50 44 93 76 63 53 45 39 91 84 76 70 64 59 91 81 71 62 56 50 91 78 66 57 49 43 91 75 62 52 45 39 87 77 68 60 54 48 87 75 64 55 48 42 87 73 61 51 44 38 83 74 65 58 52 47 83 72 62 54 47 42 83 70 59 50 43 38 80 71 63 56 50 45 80 70 60 53 46 41 80 68 58 50 43 37 78 67 56 48 41 36 56 52 48 45 42 46 41 38 35 32 39 35 31 28 26 34 30 27 24 22 54 50 47 44 41 45 41 37 34 32 38 34 31 28 26 34 30 27 24 22 44 40 36 33 31 38 34 31 28 25 33 30 26 24 22 42 38 35 32 30 37 33 30 27 25 33 29 26 24 22 41 37 34 32 29 36 33 30 27 25 33 29 26 24 21 31 28 25 22 20 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 20% 50% 50 30 10 Luminance Data Lumens %Lamp %Fixture 1254 2066 3636 4352 0 4352 22.6 37.2 65.5 78.4 0.0 78.4 28.8 47.5 83.5 100.0 0.0 100.0 Angle In Deg 45 55 65 75 85 Average 0-Deg cd/sm 4601 4098 3276 Average 45-Deg cd/sm 5456 5090 3932 Average 90-Deg cd/sm 6375 5752 3575 2172 1895 2525 2137 3977 2378 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1614 1598 1558 1502 1433 1349 1256 1154 1045 926 800 669 532 394 266 160 100 47 1 45° 1614 1603 1579 1542 1496 1439 1370 1290 1200 1098 975 831 656 473 295 186 113 53 3 Across 1614 1609 1599 1588 1571 1542 1504 1455 1383 1283 1121 939 665 430 318 293 125 59 1 LER = FP77 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.12 Coefficients of Utilization 2HP2-WO-3U158S33I Electronic Ballast FB051/31K lamps 2775 lumens. Spacing criterion: (II) 1.2 x mounting height, ( ) 1.4 x mounting height. Efficiency = 69.1% Test Report: 2HP2-WO-3U158S33I rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 82 76 70 64 59 55 51 47 44 41 39 82 73 64 57 51 46 42 38 35 32 30 82 70 60 52 46 40 36 32 29 27 24 82 68 57 48 41 36 32 28 25 23 21 80 74 68 62 57 53 49 46 43 40 38 80 71 63 56 50 45 41 38 34 32 29 80 69 59 51 45 40 36 32 29 27 24 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Candela Lumens %Lamp %Fixture 1896 3040 4918 5755 0 5755 22.8 36.5 59.1 69.1 0.0 69.1 32.9 52.8 85.5 100.0 0.0 100.0 80 67 56 48 41 36 32 28 25 23 21 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 77 68 61 54 49 44 40 37 34 31 29 74 66 59 52 47 43 39 36 33 30 28 71 63 57 51 46 41 38 35 32 30 27 69 59 51 44 38 33 29 26 24 21 19 77 66 57 50 44 39 35 32 29 26 24 77 65 55 47 40 35 31 28 25 23 21 74 64 56 49 43 38 34 31 28 26 24 74 63 53 46 40 35 31 28 25 23 21 71 62 54 48 42 38 34 31 28 26 24 71 61 52 45 39 35 31 28 25 23 21 Luminance Data Angle In Deg 45 55 65 75 85 Average 0-Deg cd/sm 6643 5740 4306 3244 2782 Average 45-Deg cd/sm 7011 5703 3874 3434 2782 Average 90-Deg cd/sm 7011 4655 3974 3760 2903 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2474 2444 2370 2270 2153 2016 1863 1699 1523 1337 1138 937 729 518 337 239 149 69 5 45° 2474 2451 2412 2357 2280 2172 2032 1855 1645 1411 1161 931 683 466 351 253 156 69 3 Across 2474 2466 2468 2458 2407 2301 2132 1914 1653 1411 1115 760 559 478 391 277 168 72 1 LER = FP75 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.20 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADF101721 2015-11-03 12:37:09 2 H P 2 GX-W O 2 1 7 ORDER IN INFOR M A TION Sample Number: 2HP2GX-WO-217W23P-UNV-HB81H-U Cell Configuration 23 =2 Rows of 3, 6 Cell (2'x2') Rating Blank =Standard ATW-SW4 =Chicago Rated Heat Removal HR =Heat Removal 33 =3 Rows of 3, 9 Cell (2'x2') 1 Louver Finish I =SemiSpecular/Haze (Low Iridescent) (Silver Only) Width 2 =2' Width Series HP2 =High Performance 2" Paralux Louver P =Painted White (Standard) Option Aluminum Flange Trim Blank =SW (Single White) Trim Type G =Grid/Lay-in Standard G=Concealed T / Slot Grid F =Aluminum Flange Trim 4 SN =Single, Natural Finish RN =In Row, Natural Finish 2 4 RW =In Row, White Finish EN =End of Row, Natural Finish MZ =Modular Trim EW =End of Row, White Finish Air Supply AX =Air Supply Floating Louver Voltage 5 120V =120 Volt X =Blank Side/Floating Louver - Non Air Supply 277V =277 Volt 347V =347 Volt AVX =Air Supply Floating Louver w/Directional Air Vane UNV =Universal Voltage 120-277 0-10V Dimming Ballasts 11 5LTV8 =T8 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 14 6 5LTVS8 =T8 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 12, 13 Fifth Light DALI Ballasts 9 Options GL =Single Element Fuse White Optics WO =97% Reflective White Optics Finish GM =Double Element Fuse 5LT8 = T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 WTR =White Reveal Lamps =Lamps Installed (refer to lamp ordering Number of Lamps 2 =2 Lamps 3 =3 Lamps Wattage U15/8 =31W T8 (24") 10 EL =Emergency Installed 17 =17W T8 (24") Louver Color S =Silver 2 = 2 Ballast 7 Options REP =Riveted End Plates Packaging U = Unit Pack W=White Notes: 1 Number of Ballasts 1 = 1 Ballast Flex =Flex Installed (Reference Flex ordering information) 8 Ballast Type High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 PAL= Job Pack, out of carton PALC = Job Pack, in carton Integral End Plate Grid Lock feature not available in Heat Removal 2 Louver is recessed by 5/16" in Concealed T or Slot Grid T. 3 An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. 4 Specify row configuration, type in catalog number when ordering complete fixtures. 5 Products also available in non-US voltage and frequencies for international markets 6 Not available when specifying emergencies, voltage must be specific 7 Fixtures equipped with "EL" option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. 8 Standard off-center ballast on 3-lamp fixtures. 9 For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(3) 10 Fifthlight ballast option not available. 11 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system. 12 Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps. 13 Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions. 14 Standard 0-10V ballast not offered in 3 or 4-lamp versions SH IP P ING D A T A Catalog No. 2HP2GAX-WO-217W23P Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 28 lbs. ADF101721 2015-11-03 12:37:09