Metalux

advertisement
Metalux
D ES C R IPTION
The Paralux V Series features a proprietary “Total Light Control System”
that has been designed to eliminate glare reflections in VDT screens
by suppressing high angle brightness. The luminaire incorporates a
precision cut-off parabolic louver in a surface mount fixture. This system
complies with RP-1 and meets today’s lighting and energy management
standards. The series is available with a number of options and
accessories for application versatility. The high performance luminaire
is designed to offer maximum efficiency and performance for today’s
unique interior specifications. The Paralux V, PC|2 series is the solution
for computer environments and open office areas.
Type
Catalog #
Project
Date
Comments
Prepared by
S PEC IFIC A TION FEA T U R E S
Construction
E le ctrica l*
H inging/Latching
Nominal 6-11/16” deep housing,
die formed code gauge, prime
cold rolled steel. Smooth sides
permit flush joint for continuous
row mounting. Full seam welded
corners. Dihedral recessed top
design insures cooler ballast
operation. Die formed captive
lampholder bracket fully encloses
wiring permitting easy lampholder
replacement. Ballast/Wireway
covers easily removed without
tools.
Ballasts are CBM/ETL Class “P”.
Pressure lock lampholders. UL/CUL
listed. Suitable for damp locations.
Positive cam spring loaded, self
locking, black steel latches. Positive
hinging.
F in ish
Louver
Painted after fabrication.
Electrostatically applied baked
white polyester powder enamel
finish. Multistage cleaning
cycle, iron phosphate coating
with rust inhibitor. Conveyorized
application and baking timing
accurately controlled at an elevated
temperature.
Die formed of specular/ mirrored,
vertical grain, low iridescent
aluminum. Finish is anodic oxide
coating. Accurate precision
parabolic cells are held in place
with interlocking feature. Truecut mitered corners. Black reveal
with integral mechanical light seal
around entire perimeter of louver.
Louver protected from construction
contaminants by polyethylene
cover.
2P5MX
340
332
27 Cell
6-11/16"
[170mm]
2' X 4' PARABOLIC
3 LAMP
SPECULAR LOUVER
Paralux V
Surface Parabolic
Precision Cell Cut-Off
Parabolic
24"
[610mm]
L AM P C ONFIGUR A TI O N S
M O U N T I N G DA T A
4-1/2" [114mm]
ENERGY DATA
11/16" [17mm] K.O. (4)
6-11/16"
[170mm]
7"
7"
[178mm] [178mm]
24" [610mm]
Input Watts:
EB Ballast & STD Lamps
340 (110), 332 (91)
21-1/8"
[537mm]
24"
[610mm]
3-1/2"
[89mm]
1-1/4"
[32mm]
7/8" [22mm]
K.O. (5)
36-7/16" [926mm]
38-15/16" [989mm]
48" [1219mm]
S TEM M OUNTING D A T A
Single Fixture
Application
Consult Pre Sales
Technical Support for
Continuous Row
Application.
4 Point Suspension
Utilizes Standard KOs
(Consult Pre Sales
Technical Support.)
ES Ballast & STD Lamps
340 (136), 332 (108)
Luminaire Efficacy Rating
LER = FP-55
Catalog Number: 2P5MX-340
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $4.36
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF020508
2015-10-22 14:40:57
2 P5 M X
PH OTOM ETR IC S
C o e f fi c i e n t s o f U t i l i z a t i o n
2P5MX-332S39MI
Electronic Ballast
F32T8/35K Lamps
2900 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 60.9%
Test Report:
2P5MX332S39MI.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
72
69
65
61
58
54
51
48
44
41
38
72
67
62
57
53
49
45
41
38
34
31
72
66
59
54
49
45
41
37
34
30
27
72
64
57
51
46
42
38
34
31
27
25
71
67
64
60
57
53
50
47
44
40
38
71
66
61
56
52
48
45
41
37
34
31
71
64
59
53
49
44
41
37
33
30
27
71
63
57
51
46
42
38
34
31
27
24
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
68
63
59
55
51
47
44
40
37
33
31
65
61
57
53
49
46
43
39
36
33
30
62
59
55
52
48
45
42
39
35
32
30
61
56
52
48
43
39
36
33
29
26
23
68
62
57
52
48
44
40
37
33
30
27
68
61
55
50
45
41
38
34
31
27
24
65
60
56
51
47
43
40
36
33
29
27
65
59
54
49
45
41
37
34
30
27
24
Zonal Lumen Summary
Typical VCP Percentages
Zone
0-30
0-40
0-60
0-90
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
0-180
Lumens
%Lamp
%Fixture
2608
4237
5285
5297
5297
30.0
48.7
60.8
60.9
60.9
49.2
80.0
99.8
100.0
100.0
LER = FP-55
60 x 60
Height Along
8.5’ 10.0’
94
95
95
95
95
95
95
95
95
96
62
58
54
50
46
42
39
36
32
29
26
62
58
53
49
44
40
37
34
30
27
24
Height Across
8.5’ 10.0’
99
99
99
99
99
99
99
99
99
99
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
3048
3052
3024
45°
3048
3059
3111
2950
2839
2692
2497
2231
1755
1095
568
95
14
9
5
3
1
0
0
3161
3151
3076
3003
2847
2367
1461
617
181
17
8
5
3
1
0
0
Across ⊥
3048
3080
3193
3280
3309
3454
3490
2660
1293
712
278
24
10
7
4
3
1
0
0
Luminance Data
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $4.36
Angle
in Deg
45
55
65
75
85
Average
0-Deg
cd/sm fL
2552 744
273
79
35
10
19
5
0
0
Average
45-Deg
cd/sm fL
3404 994
520 151
31
9
19
5
0
0
Average
90-Deg
cd/sm fL
1659 484
69
20
27
7
19
5
0
0
ORDER ING INFOR M A TION
SAMPLE NUMBER: 2P5MX-332S39MI-120V-EB81-U
Width
2=2' width
Number
of Lamps
3 lamps
P=Paralux Louver
(Not included)
5=5" Louver Depth
Wattage (Length)
32=32W T8 (48")
40=40W T12 (48")
MX=Surface Mount/Floating Door
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277
(3)
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Flex=Flex Installed
EL=Emergency Installed
Louver Color
S=Silver
Cell Configuration
39=3 Row of 9, 27 Cell
Ballast Type (4)
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.
No. of
Total Harmonic Distortion < 20%
Ballast
1, 2 or 3
Louver Finish
MI=Specular/Mirrored (Low Iridescent)
VDT=VDT Soft Semi-Specular/Haze
(Low Iridescent)
(1)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
(3)
international markets. Not available when specifying emergencies, voltage must be specific.
(2)
Options
FR=Suitable for
Fire Rated
Applications
MEP=Modified
End Plate/
For End Filler
Applications
(See Accessory
Section)
20REP=20
Gauge Riveted
Endplates. For
use in New York
City.
RLS=Rotor-Lock
Socket
(T8 Lamps Only)
(Additional options
available. See
Accessory Section)
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
Products also available in non-US voltages and frequencies for
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips (1)
SH IP P ING D A T A
Catalog No.
2P5MX-332S39MI
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Wt.
42 lbs.
ADF020508
2015-10-22 14:40:57
Download