Metalux D ES C R IPTION The Paralux III Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a true 3" deep precision cell louver into a deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high performance luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. The Paralux III series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching Deep, para-contoured housing, die formed of code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/wireway cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of low iridescent, vertical grain anodized aluminum. Finish is Anodic Oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. EP3GAX2048 328T8 332 18 Cell 20" X 48" PARABOLIC 3 T8 LAMPS SEMI-SPECULAR, SPECULAR OR WHITE PAINTED LOUVER 5-5/8" [143mm] Paralux III Recessed Static or Air Supply Troffer 19-3/4" [502mm] MOUNTING D A TA L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (2) 1-1/2" [38mm] ENERGY DATA Input Watts: EB Ballast & STD Lamps 328T8 (67), 332 (81) 5-5/8" [143mm] 3" [76mm] X = 5-1/2" [140mm] X X 19-3/4" [502mm] Luminaire Efficacy Rating LER = FP-58 Catalog Number: EP3GAX2048-2U1-5/8 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.14 19-3/4" [502mm] 5-1/4" [133mm] 3-3/4" [95mm] 7-23/32" [196mm] 48" [1219mm] *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult factory.) Safe and convenient means of disconnecting power. ADF020569 2015-10-13 14:20:43 E P 3 GAX2 0 4 8 PH OTOM ETR IC S Coefficients of Utilization EP3GAX2048-332S36I Electronic Ballast F32T8/35K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 66.6% Test Report: EP3GX2048332S36I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 79 75 70 65 60 55 51 47 44 40 37 79 72 65 59 53 48 43 39 35 32 29 79 70 62 55 49 43 38 34 30 26 24 79 68 59 52 45 39 35 30 26 23 20 78 73 68 63 59 54 50 46 43 39 36 78 71 64 58 53 47 43 39 35 31 28 78 69 61 54 48 43 38 34 30 26 23 78 67 58 51 45 39 34 30 26 23 20 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 74 68 62 56 51 46 42 38 34 30 28 71 65 60 55 50 45 41 37 33 30 27 68 63 58 53 48 44 40 36 32 29 26 67 60 53 47 42 37 32 28 25 21 19 74 66 59 53 47 42 37 33 29 26 23 74 65 57 50 44 39 34 30 26 23 20 71 64 58 52 46 41 37 33 29 26 23 71 63 56 49 44 38 34 30 26 23 20 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1952 3297 5263 5598 5598 23.2 39.2 62.7 66.6 66.6 34.9 58.9 94.0 100.0 100.0 Height Along 8.5’ 10.0’ 75 69 82 76 85 80 84 80 86 84 68 62 56 51 45 40 36 32 29 25 23 68 61 55 49 43 38 34 30 26 22 20 Height Across 8.5’ 10.0’ 85 80 89 84 90 87 90 87 91 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Across ⊥ 2378 2401 2426 2454 2474 2607 2742 Along II 2378 2351 2302 2240 2158 2058 1939 45° 2378 2375 2361 2340 2310 2262 2232 1803 2261 2380 1649 1476 1281 1058 791 468 182 47 16 5 0 2141 1707 1167 800 530 259 72 31 13 4 0 1717 1216 938 801 455 125 52 26 12 4 0 89 LER = FP-58 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.14 ORDER ING INFOR M A TION SAMPLE NUMBER: EP3GAX2048-332S36I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Heat Removal (1) HR=Heat Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Series EP3=Paralux III (4) Trim Type G=Grid/Lay-in – Standard T=Concealed T /Slot Grid (2) F=Aluminum Flange Trim (6) MZ=Modular Trim Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Width 2048=20" Width x 48" Length Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 3=3 Lamps (7) Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Louver Color S=Silver W=White Cell Configuration 36=3 Rows of 6, 18 Cell (20x48) Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (1) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all (3) 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for (4) international markets. Convertibility aplies to housing only, apprpriate shielding media assemblies must be utilized. (5) Fixture also adaptable with flanged or modular trims. Not available when specifying emergencies, voltage must be (6) (7) specific. Specify row configuration, type in catalog number when ordering complete fixture. Standard off-center ballast on 3-lamp fixtures. ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A Catalog No. EP3GAX2048-332S36I Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 41 lbs. ADF020569 2015-10-13 14:20:43