Metalux D ES C R IPTION Type Catalog # The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Construction E le ctrica l* * H inging/Latching 6-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. PGAX2048 428T8 432 24 or 32 Cell 20" X 48" PARABOLIC 4 T8 LAMPS SEMI-SPECULAR LOUVER 6-5/8" [168mm] Paralux IV Recessed Air Supply Troffer 19-3/4" [502mm] MOUNTING D A TA L A MP CONF IGURA T IONS 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 1-1/2" [38mm] Input Watts: EB Ballast & STD Lamps 428T8 (93), 432 (113) 6-5/8" [168mm] 4" [102mm] X=3-5/8" [92mm] 19-3/4" [502mm] ENERGY DATA X Y X 19-3/4" [502mm] Luminaire Efficacy Rating LER = FP-49 Catalog Number: PGAX2048-432 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.86 Y=4-13/16" [122mm] 5-1/4" [133mm] 3-3/4" [95mm] 7-23/32" [196mm] 48" [1219mm] *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. C EILING C OM PA TA BI L I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult Pre Sales Technical Support.) Safe and convenient means of disconnecting power. ADF020537 2015-10-13 17:17:46 P GAX2 0 4 8 PH OTOM ETR IC S Coefficients of Utilization PGAX2048-432S46I Energy Saving Ballast FO32T8/35K Lamps 2850 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.2 x mounting height Efficiency 55.8% Test Report: PGX2048432S46I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 66 62 58 54 50 47 43 40 38 35 33 66 60 55 49 45 41 37 34 31 29 27 66 59 52 46 41 36 33 30 27 25 23 66 57 49 43 38 33 30 27 24 22 20 65 61 57 53 49 46 42 40 37 35 33 65 59 54 48 44 40 36 33 31 28 26 65 58 51 45 40 36 32 29 27 25 23 65 56 49 42 37 33 30 27 24 22 20 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 62 57 52 47 43 39 36 33 30 28 26 59 55 52 45 41 38 35 32 29 27 25 57 53 48 44 40 37 34 31 29 27 25 56 50 44 39 35 31 28 25 23 21 19 62 56 49 44 39 35 32 29 26 24 22 62 54 48 42 37 33 29 26 24 22 20 59 54 48 43 39 35 31 29 26 24 22 59 53 47 41 36 32 29 26 24 22 20 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 2521 3960 6060 6253 6253 22.5 35.4 54.1 55.8 55.8 40.3 63.3 96.9 100.0 100.0 Height Along 8.5’ 10.0’ 84 77 88 83 90 86 88 90 84 88 57 52 47 42 39 34 31 28 26 24 22 57 51 46 40 36 32 29 26 24 22 20 Height Across 8.5’ 10.0’ 89 85 92 89 92 90 92 93 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° 3295 3281 3203 3106 2969 2826 2658 2461 2243 1996 1687 1324 805 234 73 32 15 4 0 3295 3328 3346 3281 3041 2761 2512 2297 1942 1540 1229 814 361 108 48 23 9 1 0 Across⊥ 3295 3354 3405 3217 2915 2796 2522 2140 1817 1559 1271 531 209 101 49 23 8 0 0 90 91 LER = FP-49 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.86 ORDER ING INFOR M A TION SAMPLE NUMBER: PGAX2048-432S46I-120V-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Heat Removal (1) HR=Heat Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed P=Paralux IV Trim Type (2) G=Grid/Lay-in – Standard T=Concealed T /Slot (3) F=Aluminum Flange Trim (6) MZ=Modular Trim Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 4=4 Lamps Wattage 28T8=28W T8 (48") 32=32W T8 (48") Louver Color S=Silver W=White Cell Configuration 46=4 Rows of 6, 24 Cell (20x48) 48=4 Rows of 8, 32 Cell (20x48) Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Width 2048=20" width x 48" length ACCESSORIES (1) (2) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. Convertibility applies to housing only, appropriate shielding media assemblies (3) must be utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (4) (5) Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. (6) Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. EQ-CLIP-U=T-BAR Safety Earthquake Clips (3) SH IP P ING D A T A Catalog No. PGAX2048-432S46I PGAX2048-432S48I PGAX2048-432S49I Wt. 41 lbs. 41 lbs. 41 lbs. ADF020537 2015-10-13 17:17:46