Metalux

advertisement
Metalux
D ES C R IPTION
The Precision Architectural Parabolic true 3" deep, high performance
louver incorporates a precision designed optical assembly that offers the
specifier a controlled, high performance light source. The performance
level and unique design aesthetics is a result of incorporating precision
tolerance construction in both the louver optical assembly and fixture
holding. The symmetric high throw wall wash luminaire produces
uniform vertical wall illumination on both sides of luminaire from
below ceiling line downward to floor. The double wall wash distribution
eliminates “Cave Effect”. The symmetric high throw is the ideal
luminaire for wall washing applications.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
Louver
Deep, para-contoured housing, die
formed of code gauge, prime cold
rolled steel. Die embossed housing
has full length die formed stiffeners
for added strength. Ballast/
wireway cover is easily removed.
Die formed captive lampholder
bracket fully encloses lampholder
wiring permitting easy lampholder
replacement. Heavy end plates are
securely attached with interlocking
tabs and screws. Four auxiliary
fixture end suspension points
provided. KOs for continuous
row wiring. End plates have labor
saving integral Grid-Lock feature
for safety and convenience.
Housing features enable fixture to
be converted from Grid to T-option
or vice versa in the field.*
Ballast are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Die formed of specular, low
iridescent anodized aluminum.
Finish is anodic oxide coating.
Accurate precision parabolic
cells are held in place with
interlocking feature. True-cut
mitered corners. Black reveal with
integral mechanical light seal
around entire perimeter of louver.
Louver protected from construction
contaminants by polyethylene
cover.
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
EP3GAX
128T8
132
8 Cell
6-5/8"
[168mm]
1' X 4' PARABOLIC
1 T8 LAMP
SPECULAR/MIRRORED
LOUVER
Paralux III
Symmetric Wall Wash
Recessed Static or Air
Supply Troffer
11-3/4"
[298mm]
MO UNTING D A TA
L A MP CONF IGURA T IONS
Access Plate
7/8" [22mm] K.O. (2)
7/8" [22mm] K.O. (2)
6-5/8"
[168mm]
1-1/2"
[38mm]
11-3/4"
[298mm]
3"
ENERGY DATA
11-3/4"
[298mm]
Input Watts:
EB Ballast & STD Lamps
128T8 (27), 132 (30),
5-1/4" [133mm]
3-1/2" [89mm]
6-1/4" [159mm]
48" [1219mm]
Luminaire Efficacy Rating
LER = FP-47
Catalog Number: EP3GAX-132
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $5.11
C EILING C OM PA TIB IL I T Y
G
Grid/Lay-in
Standard
T
Concealed T
T
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G or T
G or T
F
MZ
MZ
(Verify compatibility/ consult
factory.)
*Convertibility applies to housing only.
Appropriate shielding media assemblies
must be utilized.
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF020542
2013-01-31 12:45:17
E P 3 GAX
PH OTOM ETR IC S
Coefficients of Utilization
EP3GAX-132-S18MISYM
Electronic Ballast
F32T8/35K Lamp
2800 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.8 x
mounting height
Efficiency 67.4%
Test Report:
EP3GX132S18MISYM.IES
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
80
74
68
62
57
52
48
44
41
37
34
80
71
63
56
50
44
40
35
31
28
25
80
68
58
51
44
38
34
30
26
22
20
80
65
55
46
40
34
29
25
22
19
16
78
72
66
61
56
51
47
43
40
36
34
78
69
61
55
49
43
39
35
31
28
25
78
67
57
50
44
38
33
29
26
22
20
78
64
54
46
40
34
29
25
22
18
16
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
75
66
59
53
47
42
38
34
30
27
24
72
64
57
51
46
41
37
33
29
26
24
69
61
55
49
44
39
36
32
28
25
23
67
57
49
42
37
31
27
23
20
17
15
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
%Lamp
%Fixture
472
885
1568
1889
1889
16.9
31.6
56.0
67.4
67.4
25.0
46.9
83.0
100.0
100.0
LER = FP-47
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $5.11
75
64
56
49
43
37
33
29
25
22
19
75
62
53
45
39
33
29
25
22
18
16
72
62
54
47
42
36
32
28
25
22
19
72
60
52
44
39
33
29
25
21
18
16
69
60
52
46
41
36
32
28
24
21
19
69
59
50
44
38
33
29
25
21
18
16
Ve r t i c a l I l l u m i n a t i o n P l o t
Continuous Row
0'
1'
Ceiling
8'
31 32
7'
30 31
6'
38 39
5'
36 37
4'
27 28
3'
20 21
2'
16 16
1'
13 14
Floor
Initial Footcandles
2'
3'
4'
5'
6'
7'
8'
32
31
39
38
28
21
17
14
32
31
39
38
29
21
17
14
31
31
39
38
29
21
17
14
32
31
39
38
29
21
17
14
32
31
39
38
28
21
17
14
32
31
39
37
28
21
16
14
31
30
38
36
27
20
16
13
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
555
553
543
528
510
489
463
433
393
332
264
199
53
5
3
2
1
0
0
Across ⊥
555
556
553
553
576
696
836
895
799
559
415
340
317
315
287
275
255
164
0
45°
555
556
556
540
531
543
582
678
721
665
487
289
182
124
97
89
76
42
0
ORDER ING INFOR M A TION
SAMPLE NUMBER: EP3GAX-132S18MISYM-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Heat Removal (1)
HR=Heat Removal
HRDO=Heat Removal
Damper Open
HRDC=Heat Removal
Damper Closed
Series
EP3=Paralux III
Trim Type (2)
G=Grid/Lay-in – Standard
T=Concealed T/Slot Grid (3)
F=Aluminum Flange Trim (6)
MZ=Modular Trim
Air Supply
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver
Non-Air Supply
AVX=Air Supply Floating Louver
with Directional Air Vane
Number
of Lamps
1=1 Lamp
Options
GL=Single Element
Fuse
GM=Double
Element Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex
ordering information)
EL=Emergency
Installed
Wattage
28T8=28W T8 (48")
32=32W T8 (48")
Louver Color
S=Silver
W=White
Cell Configuration
18=1 Row of 8, 8 Cell (1'x4')
Louver Finish
I=Semi-Specular/Haze (Low
Iridescent) Standard
MI=Specular/Mirrored (Low
Iridescent)
P=Painted
Distribution
SYM=Symmetric High Throw Wall Wash
Option – Aluminum Flange Trim (6)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Lamps Installed
Blank=No Lamps
Installed
L8835=T8 Lamp, 28W
and 32W, 3500K
L8841=T8 Lamp, 28W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Voltage (4)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277(5)
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
Options
PAF=Painted After
Fabrication
REP=Riveted
Endplates
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
(2)
NOTES: Integral end plate grid lock feature not available in heat removal. Convertibility applies to housing only, appropriate shielding media assemblies
(3)
must be utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per
(4)
(5)
fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must
(6)
be specific. Specify row configuration, type in catalog number when ordering complete fixture.
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips(3)
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper
Lighting Representative for availability and ordering information.
SH IP P ING D A T A
Catalog No.
Wt.
EP3GAX-128T8S18MISYM 29 lbs.
EP3GAX-132S18MISYM
29 lbs.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADF020542
2013-01-31 12:45:17