Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer the marketplace a parabolic choice when economics and shallow plenum space are factors. The Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 5-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Ballast/wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. P2GAX 128T8, 132 228T8, 232 328T8, 332 11, 13, 22, 26 or 33 Cell 5-5/8" [143mm] 1' X 4' PARABOLIC 1, 2 OR 3 T8 LAMP SEMI-SPECULAR LOUVER 11-3/4" [298mm] MO UNTING D A TA Paralux II Recessed Air Supply Troffer ENERGY DATA L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 11-3/4" [298mm] 5-1/4" [133mm] 3-1/2" [89mm] 7-23/32" [196mm] 2" [51mm] 11-3/4" [298mm] Luminaire Efficacy Rating LER = FP-53 Catalog Number: P2GAX-132S113I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.53 5-5/8" [143mm] 2" [51mm] 48" [1219mm] Input Watts: EB Ballast & STD Lamps 128T8 (27), 132 (30), 228T8 (48), 232 (55), 328T8 (67), 332 (81) 5-5/8" [143mm] 3-1/4" [83mm] 11-3/4" [298mm] Luminaire Efficacy Rating LER = FP-57 Catalog Number: P2GAX-132S211I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 5-5/8" [143mm] 2" [51mm] 1-5/8" [41mm] 11-3/4" [298mm] *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ (Verify compatibility/ consult Pre Sales Technical Support.) **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020583 2015-10-13 14:47:06 P 2GAX 1 , 2 OR 3 L T 8 PH OTOM ETR IC S P2GAX-132S113I Electronic Ballast FO32T8 Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.8 x mounting height Efficiency 68.3% Test Report: P2GX132S113I.IES LER = FP-53 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.53 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 655 652 640 620 594 563 527 486 439 386 323 237 124 51 27 14 7 3 0 Across⊥ 655 661 667 661 652 654 667 692 765 819 854 703 330 174 94 29 8 3 0 45° 655 658 659 650 630 607 585 576 569 571 568 494 320 121 38 15 7 2 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 81 73 66 59 53 47 42 37 33 29 26 81 71 62 54 47 41 36 31 27 23 21 81 69 59 50 43 37 32 27 23 20 17 79 74 69 63 58 53 49 45 41 37 35 79 72 65 58 52 46 41 36 32 29 26 79 70 61 54 47 41 35 31 27 23 21 79 68 58 50 43 37 31 27 23 20 17 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 527 894 1764 1914 1914 %Lamp 18.8 31.9 63.0 68.3 68.3 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1416 1409 1383 1340 1284 1217 1139 1050 949 832 692 498 253 102 52 28 14 5 0 Across⊥ 1416 1425 1433 1415 1389 1369 1354 1372 1442 1440 1272 1081 745 313 154 48 14 5 0 45° 1416 1420 1417 1393 1347 1291 1232 1184 1130 1088 1019 842 543 224 68 27 12 4 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 81 76 70 65 60 55 50 46 42 38 35 P2GAX-232S113I Electronic Ballast FO32T8 Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 66.5% Test Report: P2GX232S113I.IES LER = FP-57 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.21 20% 50% 50 30 10 30% 50 30 10 50 76 69 62 56 50 44 40 35 31 28 25 73 66 60 54 49 43 39 34 31 27 25 70 64 58 52 47 42 38 33 30 26 24 76 67 59 52 46 40 35 30 26 23 20 76 66 57 49 42 36 31 27 23 19 17 73 65 58 51 45 39 34 30 26 23 20 73 64 56 48 42 36 31 27 23 19 17 10% 30 10 70 63 56 50 44 38 34 30 26 22 20 70 62 54 48 41 36 31 26 23 19 17 0% 0 68 61 53 46 40 34 29 25 21 18 16 Ty p i c a l VC P Pe r c e n t a g e s %Fixture 27.5 46.7 92.2 100.0 100.0 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 85 81 89 85 90 87 90 87 91 89 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Height Across 8.5’ 10.0’ 75 68 82 75 85 80 84 79 87 83 79 74 69 64 59 54 50 46 42 38 35 79 72 64 58 52 46 41 37 33 29 27 79 69 61 53 47 41 36 32 28 24 21 79 67 58 50 43 37 32 28 24 20 18 77 72 67 62 57 53 48 44 41 37 35 77 70 63 57 51 46 41 37 33 29 26 77 68 60 53 46 40 36 31 27 24 21 20% 77 66 57 49 43 37 32 28 24 20 18 50% 50 30 10 30% 50 30 10 50 74 67 61 55 49 44 40 36 32 28 26 71 65 59 53 48 43 39 35 31 28 25 68 63 57 52 47 42 38 34 30 27 24 74 66 58 52 45 40 35 31 27 24 21 74 64 56 49 42 36 32 27 24 20 18 71 64 57 50 44 39 34 30 27 23 21 71 62 55 48 42 36 31 27 23 20 18 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1126 1878 3442 3727 3727 %Lamp 20.1 33.5 61.5 66.5 66.5 %Fixture 30.2 50.4 92.4 100.0 100.0 10% 30 10 68 61 55 49 44 38 34 30 26 23 20 Height Along 8.5’ 10.0’ 76 70 80 75 83 78 84 80 85 81 68 61 53 47 41 36 31 27 23 20 18 0% 0 67 59 52 46 40 34 30 26 22 19 16 Height Across 8.5’ 10.0’ 63 57 73 65 77 70 77 72 81 76 ORDER ING INFOR M A TION SAMPLE NUMBER: P2GAX-132S113I-UNV-EB81-U Number of Lamps (4) 1, 2 or 3 lamps Rating Blank= Standard ATW-SW4= Chicago Rated Wattage 28T8=28W T8 (48") 32=32W T8 (48") Heat Removal HR=Heat Removal (1) HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Louver Color S=Silver W=White Cell Configuration 111=1 Row of 11, 11 Cell (1' x 4') 113=1 Rows of 13, 13 Cell (1' x 4') 211=2 Rows of 11, 22 Cell (1' x 4') 213=2 Rows of 13, 26 Cell (1' x 4') 311=3 Rows of 11, 33 Cell (1' x 4') Width Blank=1' Width or 20" Width Series P2=Paralux II Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted (2) Trim Type G=Grid/Lay-in – Standard T=Concealed T/Slot Grid (3) F=Aluminum Flange Trim (7) MZ=Modular Trim Voltage (5) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (6) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Option – Aluminum Flange Trim (7) Blank=SW (Single White) Air Supply Type Color AX=Air Supply Floating Louver ‘S’ Single ‘N’ Natural X=Blank Side/Floating Louver ‘R’ In Row ‘W’ White Non-Air Supply ‘E’ End of Row AVX=Air Supply Floating Louver with Directional (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. Convertibility applies to housing Air Vane only, appropriate shielding media assemblies must be utilized. Fixture also adaptable with flanged or modular (3) Options PAF=Painted After Fabrication REP=Riveted Endplates (4) trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Standard (5) off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for interna(6) (7) tional markets. Not available when specifying emergencies, voltage must be specific. Specify row configuration, type in catalog number when ordering complete fixture. Specifications & dimensions subject toc hange without notice. Consult your Eaton Representative for availability and ordering information. Eaton 1121 Highway 74 South Specifications and Peachtree City, GA 30269 dimensions subject to P: 770-486-4800 change without notice. www.eaton.com/lighting ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(3) SH IP P ING DATA Catalog No. P2GAX-132S111I P2GAX-132S113I P2GAX-232S211I P2GAX-232S213I P2GAX-332S311I Wt. 29 lbs. 29 lbs. 29 lbs. 29 lbs. 29 lbs. ADF020583 2015-10-13 14:47:06