METALUX ® DESCRIPTION Type GC8 is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest T8 lamp and micro electronic ballast technology for optimal performance and energy efficiency. The GC8 is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # The GC8 Series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by Project Date Comments SPECIFICATION FEATURES Construction Electrical Frame/Shielding Rigid housing is die formed of code gauge prime cold rolled steel and features full length die-formed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Micro ballast cover*** reduces ballst shadow for superior lens brightness uniformity and is easily removed without tools. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Roto-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations.** Die formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Flat and regressed aluminum doors also available. Positive light seals. Light stabilized, acrylic prismatic lens. Standard #12 pattern. Numerous additional shielding options available. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. “PAF” Painted After Fabrication option also available. Hinging/Latching Positive Cam latch with baked white enamel finish. Safetylock T-hinges allow hinging and latching either side. 2GC8 328T8 332 Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 3-1/4" [83mm] 2' X 4' TROFFER 3 T8 LAMPS Specification T8 Troffer ENERGY DATA Input Watts: EB Ballast & STD Lamps 328T8 (67) 332 (91) 23-3/4" [603mm] DOOR FRAMES MOUNTING DATA 23-3/4" [603mm] Luminaire Efficacy Rating LER = FL-83 Catalog Number: 2GC8-332A GC8 F lat, White Steel Location of Standard Access Opening GC8FA F lat, E xtruded White Alum inum GC8RA D eep, R egressed, E xtruded Natural Alum inum 1-1/2" [38mm] 2-11/16" [69mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 1" [26mm] 1-1/2" [38mm] 3-1/2" [89mm] 47-15/16" [1218mm] LAMP CONFIGURATIONS 3-1/8" [79mm] **Consult Pre Sales Technical Support. ***Full sized ballast cover for biaxial lamps and emergency option may apply. 3-1/4" [83mm] X=5-3/8" [137mm] X ****When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. X 23-3/4" [603mm] CEILING COMPATIBILITY G Grid/Lay-in Standard Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.89 G Concealed T G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G F (Verify compatibility/ consult factory.) COOPER LIGHTING LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF031997 2GC8 PHOTOMETRICS 2GC8-332A Electronic Ballast (3) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 85% Test Report: 2GC8-332A.IES LER = FL-83 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.89 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2985 2987 2947 2881 2785 2659 2500 2309 2074 1797 1491 1194 935 711 520 370 263 141 11 45° 2985 2971 2946 2906 2840 2753 2628 2470 2253 1979 1683 1368 1023 692 441 296 227 139 26 Across 2985 2981 2971 2950 2907 2837 2737 2603 2424 2166 1839 1471 1109 800 576 433 319 184 37 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 101 89 78 69 62 55 50 45 42 38 35 101 101 86 83 73 68 63 57 55 49 48 43 43 37 38 33 34 30 31 27 29 24 99 91 83 76 70 64 59 55 51 48 45 99 99 87 84 77 72 68 62 61 54 55 48 49 42 45 38 41 34 38 31 35 28 99 81 67 57 49 42 37 33 30 27 24 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 94 84 74 66 59 53 48 44 40 37 34 90 80 71 63 57 51 46 42 39 36 33 87 77 69 61 55 50 45 41 38 35 32 85 72 61 52 45 39 35 31 27 25 22 94 81 70 60 53 47 42 37 34 31 28 94 79 66 56 48 42 37 33 29 27 24 90 78 68 59 52 46 41 37 33 30 28 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2371 3907 6627 7909 7909 %Lamp 25.5 42.0 71.3 85.0 85.0 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3509 3509 3454 3362 3241 3086 2908 2683 2321 1704 1126 734 408 271 212 196 150 77 5 45° 3509 3490 3451 3388 3301 3189 3045 2848 2496 1907 1373 1028 697 448 284 146 79 73 17 Across 0 3509 3501 3474 3433 3379 3306 3223 3105 2839 2163 1281 742 422 235 170 159 132 81 16 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 93 85 78 72 66 61 57 53 49 46 2GC8-332A156 Electronic Ballast (3) F32T8 lamps 3100 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 82.5% Test Report: 2GC8332A19_156.IES LER = FL-80 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 Candela %Fixture 30.0 49.4 83.8 99.9 100.0 Average 0-Deg cd/sm 4706 3339 2698 2293 2595 90 76 64 55 48 41 37 33 29 26 24 Average 45-Deg cd/sm 4489 3826 2626 1834 2558 87 76 66 57 50 45 40 36 33 30 27 87 74 63 54 47 41 36 32 29 26 24 Average 90-Deg cd/sm 4913 4114 3036 2683 3386 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 98 91 84 78 72 67 62 58 54 51 48 98 88 79 70 63 57 52 48 44 40 37 98 85 74 65 57 51 46 41 37 34 31 98 82 70 60 52 46 41 36 33 30 27 96 89 82 76 70 65 61 57 53 50 47 96 86 77 69 62 57 51 47 43 40 37 96 83 73 64 56 50 45 41 37 34 31 20% 96 81 69 59 52 46 41 36 33 30 27 50% 50 30 10 30% 50 30 10 50 92 83 74 67 60 55 50 46 42 39 36 88 79 72 65 59 53 49 45 41 38 35 84 77 69 63 57 52 47 44 40 37 35 92 80 70 62 55 49 44 40 37 33 31 92 78 67 58 51 45 40 36 33 30 27 88 78 68 61 54 48 44 40 36 33 30 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2762 4546 6894 7671 7671 %Lamp 29.7 48.9 74.1 82.5 82.5 %Fixture 36.0 59.3 89.9 100.0 100.0 Average 0-Deg cd/sm 3865 2053 1029 1215 1417 88 76 66 57 50 45 40 36 32 29 27 10% 30 10 Average 45-Deg cd/sm 4326 2875 1700 905 1343 84 75 67 59 53 48 43 39 36 33 30 84 74 64 56 50 44 40 36 32 29 27 0% 0 82 72 63 55 48 43 38 34 31 28 25 Average 90-Deg cd/sm 4906 2075 892 985 1491 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF031997 2GC8 ORDERING INFORMATION SAMPLE NUMBER: 2GC8-332A-UNV0V-EB81-U Rating (5) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid F=Flange Trim Series C8=Specification T8 Troffer Door Frame Standard=Flat White Steel Door (Leave Blank) FA=Flush White Extruded Aluminum c/w Spring Latch RA=Regressed White Extruded Aluminum FAN=Flush Natural Anodized Extruded Aluminum RAN=Regressed Natural Anodized Extruded Aluminum FAB=Flush Black Extruded Aluminum RAB=Regressed Black Extruded Aluminum (1) Number of Lamps (2) 3 Lamps (Not included) Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") A=#12 Pattern Acrylic A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) PB1S=Silver Parabolic Louver (1/2" x 1/2" x 1/2") Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed Options FR=Fire Rated Label REP=Riveted End Plates PAF=Painted After Fabrication Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton Fifth Light DALI Ballasts (7) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast compartment on (3) (4) 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available (5) when specifying emergencies, voltage must be specific. For NYC rated product, see separate specification sheets. (6) (7) Specify row configuration, type in catalog number when ordering complete fixture. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) FCTKA-24W-U=Field Installed Flange Kit FCTK A – 24 R W – U Trim Kit Field Convertible 22=2' x 2' 24=2' x 4' N=Natural W=White Blank=Single R=In Row E=End Row U=Unit Pack Aluminum SHIPPING INFORMATION Catalog No. 2GC8-328T8A 2GC8-332A Wt. 20 lbs. 20 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF031997