COOPER LIGHTING - METALUX ® DESCRIPTION Type The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a low profile housing. T8 dedication and optimized lamp to lens spacing provides the best in energy efficiency and optical control. The GR8’s shallow, low profile housing is compatible with even highly restrictive plenums. Luminaires are compatible with today’s popular ceiling systems. Catalog # The GR8 offers great performance and great quality. The series is an excellent choice for commercial offices, schools, hospitals, retail merchandising and many other applications. Prepared by Project Date Comments SPECIFICATION FEATURES Construction Electrical** Frame/Shielding Unitized low profile recessed housing is die formed of code gauge prime cold rolled steel with full length stiffeners and unibody endplate for added strength. Ballast cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring for easy lampholder replacement. Ample KOs are provided for continuous row wiring. Built-in gridlock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor-lock lampholders. Biaxial models use 2G11 base lampholders with doubleedge wiping action pressure-lock contacts and horizontally oriented lamp support clips. UL/CUL listed. Suitable for damp locations. Heavy gauge flat steel door is die formed with reinforced mitered corners. Housing and door frame assemblies incorporate full width mechanical light traps. Light stabilized, acrylic prismatic lens. Finish Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Lighting grade baked white enamel finish with premium reflectance for high efficiency. Hinging/Latching Positive spring loaded steel latches and safety lock T-hinges provide secure, high quality door fit and allow hinging and latching from either side. Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2GR8 317 3BX40 3U1-5/8 2' X 2' TROFFER 3 LAMP General Purpose T8 Commercial Troffer 3-1/4" [83mm] 23-3/4" [603mm] ENERGY DATA Input Watts: MOUNTING DATA EB Ballast & STD Lamps 317 (52), 3BX40 (98), 3U1-5/8 (88) LAMP CONFIGURATIONS 317 1" [26mm] X=5-3/8" [137mm] 23-3/4" [603mm] ES Ballast & STD Lamps 317 (69), 3BX40 (125), 3U1-5/8 (105) 3-1/4" [83mm] 2-11/16" [69mm] X X Luminaire Efficacy Rating LER = FL-61 Catalog Number: 2GR8-317A 23-3/4" [603mm] 3BX40 3-1/4" [83mm] 1-1/2" [38mm] X=13/16" [21mm] Y=4-9/16" [116mm] 2-3/4" [70mm] 5-3/4" [146mm] 23-15/16" [610mm] Y Y X X 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 3U1-5/8 DOOR FRAMES *Standard G (Grid) Type Fixtures can be field converted by adding trim kits. See Compatibility Section or Consult Factory. 3-1/4" [83mm] X=1-5/8" [42mm] Y=4-3/8" [112mm] 2GR8 F lat, White Steel ( White L atches) X Y Y X **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 23-3/4" [603mm] ***When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T COOPER LIGHTING G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G G*** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF012706 2GR8 PHOTOMETRICS 2GR8-317A Electronic Ballast (3) F17T8 lamps 1350 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 73% Test Report: 2GR8317A.IES LER = FL-61 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1171 1167 1150 1121 1079 1025 961 877 772 658 530 419 323 238 180 140 103 54 0 Across ⊥ 1171 1172 1169 1161 1145 1118 1069 1009 932 826 687 538 395 273 207 165 120 62 0 45° 1171 1167 1157 1139 1111 1074 1021 948 855 729 599 474 335 223 150 118 99 58 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 87 80 73 67 62 57 53 49 46 43 40 87 77 68 60 54 48 44 40 36 33 31 87 74 63 54 48 42 37 34 30 28 25 87 71 59 50 43 37 33 29 26 24 21 85 78 71 66 60 56 52 48 45 42 39 85 75 66 59 53 47 43 39 36 33 30 85 72 62 54 47 42 37 33 30 27 25 85 70 58 50 43 37 33 29 26 24 21 20% 50% 50 30 10 30% 50 30 10 50 81 72 64 57 51 46 42 38 35 32 30 78 69 61 55 49 44 40 37 34 31 29 75 67 59 53 48 43 39 36 33 31 28 81 70 60 52 46 41 36 33 30 27 25 81 68 57 49 42 37 32 29 26 23 21 78 67 58 51 45 40 36 32 29 27 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 927 1516 2507 2957 2957 %Lamp 22.9 37.4 61.9 73.0 73.0 %Fixture 31.3 51.3 84.8 100.0 100.0 Average 0-Deg cd/sm 3269 2567 1979 1901 2177 78 66 56 48 41 36 32 29 26 23 21 Average 45-Deg cd/sm 3622 2904 1854 1602 2338 10% 30 10 75 65 57 50 44 39 35 32 29 26 24 75 64 55 47 41 36 32 28 26 23 21 0% 0 73 62 53 45 39 34 30 27 24 22 20 Average 90-Deg cd/sm 4104 3296 2270 2240 2499 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF012706 2GR8 ORDERING INFORMATION SAMPLE NUMBER: 2GR8-317A-UNV-EB81-U Rating (5) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) Series R8=General Purpose T8 Commercial Troffer (1) Number of Lamps (4) 3=3 Lamps (Not included) Wattage 17=17W T8 (24") U1-5/8=31W T8 (24" )(7) BX40=40W Biaxial (24") Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thick) A19/156=#19 Pattern Acrylic (.156" Thick) PB1S=Silver Parabolic Flanged Louver (1/2" x 1/2" x 1/2") Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed (1) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (2) fixture. Products also available in non-US voltages and frequencies for international markets. (3) (4) Not available when specifying emergencies, voltage must be specific. Standard off-center (5) ballast compartment on 3-lamp fixtures. For NYC rated product, see separate specification (6) (7) sheets. Not available in UNV voltages. Must specify voltage. Fifthlight ballast option not (8) available. For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% EB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20% (6) TEB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% (6) ER5 = T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options FR=Fire Label Packaging U=Unit Pack ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) FCTKA-22W-U=Field Installed Flange Kit FCTK A – 24 R W – U Trim Kit Field Convertible 22=2' x 2' 24=2' x 4' N=Natural W=White Blank=Single R=In Row E=End Row U=Unit Pack Aluminum Fifth Light DALI Ballasts (8) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 5LT5B = T5 Biax DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts SHIPPING INFORMATION Catalog No. Wt. 2GR8-317A 2GR8-3BX40A 2GR8-3U1-5/8 10 lbs. 10 lbs. 10 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF012706