METALUX ® DESCRIPTION GC8 is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated to the latest T8 lamp and micro electronic ballast technology for optimal performance and energy efficiency. The GC8 is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # The GC8 series features efficiency, quality and performance. The series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by Type Project Date Comments SPECIFICATION FEATURES Construction Electrical Frame/Shielding Rigid housing is die formed of code gauge prime cold rolled steel and features full length dieformed stiffeners and unibody endplate for added strength. Side flanges are hemmed. Innovative design provides superior lens brightness uniformity and visual comfort. Micro ballast cover*** reduces ballst shadow for superior lens brightness uniformity and is easily removed without tools. Die formed captive lampholder brackets fully enclose lampholder wiring permitting easy lampholder replacement. Unibody endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. Ample KOs are provided for continuous row wiring. Endplates have integral Grid-lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Rotor-lock T8 lampholders. Biaxial models use 2G11 base lampholders with double-edge wiping action pressure-lock contacts and horizontally oriented lamp support clips. UL/CUL listed. Suitable for damp locations.** Die formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Flat and regressed aluminum doors also available. Positive light seals. Light stabilized, acrylic prismatic lens. Standard #12 pattern. Numerous additional shielding options available. Finish Controls Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Housing and ballast cover finished with new 90% reflective white enamel for superior performance. “PAF” Painted After Fabrication option also available. Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. Hinging/Latching 2GC8 317 3BX40 3U1-5/8 2' X 2' TROFFER 3 LAMPS Specification T8 Troffer Positive Cam latch with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. ENERGY DATA 3-1/4" [83mm] Input Watts: EB Ballast & STD Lamps 317 (56), 3BX40 (98), 3U1-5/8 (88) ES Ballast & STD Lamps 317 (68), 3BX40 (125), 3U1-5/8 (105) 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA 3U1-5/8 317 1" [26mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FL-63 Catalog Number: 2GC8-317 2-11/16" [69mm] 1-1/2" [38mm] X=5-3/8" [137mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.81 3-1/4" [83mm] 3-1/4" [83mm] X X=1-5/8" [41mm] X 23-3/4" [603mm] X X X 5-3/8" 5-3/8" [137mm] [137mm] 23-3/4" [603mm] DOOR FRAMES GC8 F lat, White Steel 2-3/4" [70mm] 5-3/4" [146mm] GC8FA F lat, E xtruded White Alum inum *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. GC8RA D eep, R egressed, E xtruded Natural Alum inum 23-15/16" [610mm] ***Full sized ballast cover for biaxial lamps and emergency option may apply. ****When ordering Flange Kit for installation in drywall ceilings, see options and accessories compatibility section and ordering logic. CEILING COMPATIBILITY G Grid/Lay-in Standard G Concealed T G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange G G G F LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. (Verify compatibility/ consult factory.) COOPER LIGHTING ADF041298 2GC8 PHOTOMETRICS 2GC8-317A Electronic Ballast (3) F17/SPX35 T8 lamps 1300 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 75.5% Test Report: 2GC8317A.IES LER = FL-63 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.81 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1213 1210 1191 1161 1120 1064 994 905 804 683 553 435 335 250 186 143 107 56 0 Across ⊥ 1213 1215 1211 1202 1184 1156 1106 1040 960 851 708 559 404 284 213 171 125 63 0 45° 1213 1209 1198 1180 1151 1111 1056 980 884 760 620 486 347 229 154 121 102 60 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 90 83 76 70 64 59 55 51 47 44 42 90 79 70 62 55 50 45 41 38 35 32 90 76 65 56 49 43 39 35 31 29 26 90 74 61 52 44 39 34 30 27 24 22 88 81 74 68 62 58 53 50 46 43 41 88 78 69 61 54 49 44 40 37 34 32 88 88 75 72 64 60 56 51 49 44 43 38 38 34 34 30 31 27 28 24 26 22 20% 50% 50 30 10 30% 50 30 10 50 84 74 66 59 53 47 43 39 36 33 31 80 72 64 57 51 46 42 38 35 32 30 77 69 61 55 49 45 41 37 34 32 29 84 72 62 54 48 42 38 34 31 28 26 84 70 59 50 43 38 34 30 27 24 22 80 80 70 68 60 58 53 49 46 43 41 38 37 33 33 30 30 27 28 24 25 22 Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 %Lamp 23.7 38.7 64.1 75.5 75.5 %Fixture 31.4 51.3 84.8 100.0 100.0 90 Across ⊥ 1344 1344 1336 1320 1297 1270 1241 1199 1115 861 489 282 164 94 69 67 54 31 0 45° 1344 1339 1324 1298 1263 1219 1163 1094 982 748 511 393 268 168 95 59 34 26 0 0 Coefficients of Utilization Zonal Lumen Summary Lumens 960 1569 2594 3059 3059 Candela 2GC8-317A156 Electronic Ballast Angle Along II (3) F17/SPX35 0 1344 T8 lamps 5 1340 1300 lumens 10 1319 15 1283 Spacing criterion: 20 1234 (II) 1.2 x mounting 25 1172 height, (⊥) 1.4 x 30 1102 mounting height 35 1015 40 905 Efficiency 72.6% 45 700 Test Report: 50 435 55 267 2GC8317A19_156.IES 60 158 LER = FL-60 65 91 70 65 Yearly Cost of 1000 75 63 lumens, 3000 hrs at 80 52 .08 KWH = $4.00 85 29 Candela Average 0-Deg cd/sm 3394 2665 2078 1941 2258 10% 30 10 Average 45-Deg cd/sm 3776 2977 1904 1643 2419 77 67 59 51 45 41 36 33 30 27 25 77 66 56 49 42 37 33 29 27 24 22 0% 0 76 64 55 47 41 36 31 28 25 23 21 Average 90-Deg cd/sm 4228 3424 2361 2321 2540 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 86 80 74 69 64 59 55 51 48 45 42 86 77 69 62 56 51 46 42 39 36 33 86 75 65 57 50 45 40 36 33 30 28 86 72 61 53 46 40 36 32 29 26 24 84 78 72 67 62 57 53 50 47 44 41 84 76 68 61 55 50 45 41 38 35 33 84 73 64 56 50 44 40 36 33 30 27 84 71 61 52 46 40 36 32 29 26 24 20% 50% 50 30 10 30% 50 30 10 50 81 73 65 59 53 48 44 40 37 34 32 77 70 63 57 52 47 43 39 36 34 31 74 67 61 55 50 46 42 38 36 33 31 81 71 62 55 49 44 39 35 32 30 27 81 69 59 51 45 40 36 32 29 26 24 77 68 60 53 48 43 39 35 32 29 27 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 1058 1743 2649 2940 2940 %Lamp 26.1 43.0 65.4 72.6 72.6 %Fixture 36.0 59.3 90.1 100.0 100.0 Average 0-Deg cd/sm 3478 1636 757 855 1169 77 67 58 51 45 39 35 32 29 26 24 10% 30 10 74 66 59 52 47 42 38 34 31 29 27 Average 45-Deg cd/sm 3717 2407 1397 801 1048 74 65 57 50 44 39 35 31 28 26 24 0% 0 73 64 55 48 43 38 34 30 27 25 22 Average 90-Deg cd/sm 4278 1727 781 910 1250 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF041298 2GC8 ORDERING INFORMATION SAMPLE NUMBER: 2GC8-317A-UNV-EB81-U Rating (6) Blank= Standard ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (1) (Standard) G=Concealed T G=Slot Grid F=Flange Trim Series C8=Specification T8 Troffer Standard=Flat White Steel Door (Leave Blank) FA=Flush White Extruded Aluminum c/w Spring Latch RA=Regressed White Extruded Aluminum FAN=Flush Natural Anodized Extruded Aluminum RAN=Regressed Natural Anodized Extruded Aluminum FAB=Flush Black Extruded Aluminum RAB=Regressed Black Extruded Aluminum (1) Number of Lamps (2) 3 Lamps (Not included) Wattage 17=17W T8 (24") U1-5/8=31W T8 (24")(10) BX40=40W Biax (24") Shielding A=#12 Acrylic Pattern A125=#12 Pattern Acrylic (.125" Thickness) A19/156=#19 Pattern Acrylic (.156" Thickness) PB1S=1/2" x 1/2" x 1/2" Silver Parabolic Louver (Styrene) Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (3) 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse Lamps=Lamps Installed Flex=Flex Installed EL=Emergency Installed (2) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Standard off-center ballast compartment (3) (4) on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not (5) (6) available when specifying emergencies, voltage must be specific. Consult Pre Sales Technical Support. For NYC (7) rated product, see separate specification sheets. Specify row configuration, type in catalog number when ordering (8) (9) complete fixture. Not available in UNV voltages. Must specify voltage. For a complete listing of Fifthlight (10) Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. Fifthlight ballast option not available. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 = T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 Options LAO=Less Access Opening(5) FR=Fire Rated Label REP=Riveted End Plates PAF=Painted After Fabrication Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton Fifth Light DALI Ballasts (9) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (1) FCTKA-22W-U=Field Installed Flange Kit FCTK A – 24 R W – U Trim Kit Field Convertible 22=2' x 2' 24=2' x 4' N=Natural W=White Blank=Single R=In Row E=End Row U=Unit Pack Aluminum SHIPPING INFORMATION Catalog No. Wt. 2GC8-3U1-5/8A 2GC8-317A 12 lbs. 12 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 2/24/16 ADF041298