COOPER LIGHTING - METALUX ® DESCRIPTION The GCAML Series features a deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. The series produces total uniformity of light in the luminous area and is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Type Catalog # Project Date Comments The specification luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. The GCAML Series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Prepared by SPECIFICATION FEATURES A…Construction B…Electrical* D …H i n g i n g / L a t ch i n g Deep para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep V ballast/wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy gauge endplates are securely attached with interlocking tabs and screws assure accurate row length without build-up. Ample KOs for continuous row wiring. Endplates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety-lock T-hinges allow hinging and latching either side. C…Finish Low brightness, 1-1/2" deep semispecular/haze parabolic aluminum louver. Finish is anodic oxide coating. Accurate parabolic cells are held in place with inter-locking feature. Frameless, full floating effect louver assembly. Black reveal around entire perimeter of louver. (See Ordering Information). Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. A B E…Frame/Shielding C 2GCAML 217 317 2U6T8 2U1-5/8 3U1-5/8 2BX40 3BX40 D E 4-5/8" [117mm] 2' X 2' TROFFER 2 OR 3 LAMPS 23-3/4" [603mm] LAMP CONFIGURATIONS (2 LAMP) MOUNTING DATA (2 LAMP) 7/8" [22mm] K.O. (2) S p e c i f i c a t i o n D e e p Tr o ff e r Access Plate 7/8 [22mm] K.O. (2) 4-5/8" [117mm] 4-5/8" [117mm] 10-3/4" [273mm] 1-1/2" [38mm] 1-1/2" [38mm] 23-3/4" [603mm] 23-3/4" [603mm] 23-3/4" [603mm] 1-1/2" [38mm] X=4-5/8" [117mm] 6" X [152mm] 6" [152mm] 23-3/4" [603mm] 5-1/4" [133mm] 6-1/4" [159mm] 7/8" [22mm] K.O. (4) 1-1/2" [38mm] 23-3/4" [603mm] Access Plate 7/8 [22mm] K.O. (2) 7" 7" [178mm] [178mm] 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.30 4-5/8" [117mm] G Grid/Lay-in Standard G Concealed T COOPER LIGHTING Luminaire Efficacy Rating LER = FP-56 Catalog Number: 2GCAML-2U6T8S66I 23-3/4" [603mm] 23-3/4" [603mm] CEILING COMPATIBILITY EB Ballast & STD Lamps 217 (36) , 317 (56), 2U6T8 (61) 2U1-5/8 (61) , 3U1-5/8 (91) 2BX40 (67) 8-7/8" X [225mm] 1-1/2" [38mm] 4-5/8" [117mm] 7" 7" [178mm] [178mm] X MOUNTING DATA (3 LAMP) LAMP CONFIGURATIONS (3 LAMP) 1-1/2" [38mm] Input Watts: 1-1/2" [38mm] X=1-5/8" [41mm] 24" [610mm] 4-5/8" [117mm] ENERGY DATA 4-5/8" [117mm] 4-5/8" [117mm] 3-3/4" [95mm] 10-1/2" [267mm] 1-1/2" [38mm] 1-1/2" [38mm] X=1-5/8" [41mm] G Slot Grid X 7" X 7" X [178mm] [178mm] 23-3/4" [603mm] F Aluminum Flange Trim With Supporting Swing Gates 3-3/4" [95mm] 5-1/4" [133mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 6-1/4" [159mm] **Consult Pre Sales Technical Support. 24" [610mm] MZ Modular Trim With Supporting Swing Gates Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020645 2GCAML PHOTOMETRICS Coefficients of Utilization 2GCAML-2U6T8S66I Electronic Ballast FB31T8/TL735Lamps 2650 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 63.7% Test Report: LSI14328 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 76 71 66 60 56 51 47 43 76 68 61 55 49 44 39 35 76 66 58 51 44 39 34 30 76 64 55 47 41 35 30 27 40 32 27 23 37 29 23 20 34 26 21 18 74 69 64 59 55 50 46 42 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 68 62 56 51 45 40 36 33 74 67 60 54 48 43 39 35 74 65 57 50 44 38 34 30 74 63 54 47 40 35 30 26 71 64 58 52 47 42 37 34 71 63 55 49 43 37 33 29 71 61 53 46 40 34 30 26 39 31 36 28 33 26 26 23 21 23 20 17 30 27 25 26 23 23 20 20 17 68 61 54 48 42 37 33 29 68 59 52 45 39 34 30 26 65 60 54 49 44 39 36 32 65 58 51 44 39 33 29 26 64 56 49 43 38 32 28 24 30 25 27 22 24 20 22 20 17 29 25 22 26 22 19 24 20 17 21 18 16 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1069 1726 2985 3374 3374 20.2 32.6 56.3 63.7 63.7 31.7 51.2 88.5 100.0 100.0 Height Along 8.5’ 10.0’ 67 63 75 69 79 73 79 75 82 78 65 59 52 47 41 36 32 28 Height Across 8.5’ 10.0’ 62 57 71 64 76 70 76 72 80 76 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° 1379 1369 1338 1296 1243 1183 1110 1031 940 831 714 602 478 310 80 25 14 4 0 1379 1379 1371 1345 1296 1221 1136 1041 942 830 715 629 559 366 124 28 12 5 0 Across⊥ 1379 1383 1386 1364 1308 1241 1171 1083 974 894 935 877 697 448 112 33 14 3 0 LER = FP-56 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.30 ORDERING INFORMATION SAMPLE NUMBER: 2GCAML-2U6T8S66I-UNV-EB81-U Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated Width 2=2' Width Trim Type G=Grid/Lay-in (Standard) (1) G=Concealed T G=Slot Grid F=Aluminum Flange Trim (5) MZ=Modular Trim EMZ=Modular Trim (Extended Swing Arm Series C=Specification Deep Troffer Air Supply A=Air Handling Floating Door, Black Reveal AV=Air Handling w/Directional Vanes B=Non-Air Handling Floating Door, Black Reveal Blank=No Vane Options GL=Single Element Fuse GM=Double Element Fuse EL4=Emergency Lighting Self Contained PAF=Painted After Fabrication RIF1=Radio Interference Suppressor 20GA/REP=20 Gauge Riveted Endplates. For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Number of Lamps (2) 2 or 3 lamps Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Wattage U15/8=31W T8 (24") U6T8=31W T8 (24") 17=17W T8 (24") BX40=40W Biax (24") Ballast Type (3) Blank=Standard Magnetic Ballast (Biax & 20W) Lamps Installed EB8 =T8 Electronic Instant Start. LCWE=Cool White Energy Saving Total Harmonic Distortion < 10% L8730=F32T8 3000K No. of Ballast L8735=F32T8 3500K 1, 2 or 3 L8741=F32T8 4100K EB8 /PLUS= T8 Electronic Instant Start. (Additional options available. See Accessory Section) High Ballast Factor >1.13. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 ACCESSORIES EB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20% EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) No. of Ballast 1, 2 or 3 TEB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Louver S=Silver W=White Cell Configuration 66=6 Rows of 6, 36 Cell 77=7 Rows of 7, 49 Cell 1313=13 Rows of 13, 169 Cell Louver Finish I=Semi-Specular/Haze MI=Specular/Mirrored (Low Iridescent) P=White Finish Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Door Frame ML=Frameless Metal Parabolic (1) Options Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton SHIPPING INFORMATION (2) Catalog No. (3) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Standard off-center ballast on 3-lamp fixtures. Products also (4) (5) available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Wt. 2GCAML-2U6T8S66I 2GCAML-2U6T8S77I 2GCAML-2BX40S66I 2GCAML-3BX40S77I 2GCAML-2U1-5/8S66I 2GCAML-3U1-5/8S77I 28 lbs. 28 lbs. 28 lbs. 35 lbs. 28 lbs. 35 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 1/11 ADF020645