FAIL-SAFE

advertisement
FAIL-SAFE
®
DESCRIPTION
Optical performance and long lamp life combine with a low architectural
profile to form Fail Safe's HCS. Its cast aluminum housing and shallow,
high impact, injection molded prismatic polycarbonate refractor supports
seven lamp choices. The HCS is specifically designed for use in public
access areas where vandalism may occur. Ideal for tunnels, loading
docks, park shelters and other unsupervised outdoor areas where safety
and security remain critical.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Fa s te n e r s
Captive, stainless steel tamperresistant TORX®-head T20 screws
prevent unauthorized access.
G a s ke t
S o cke t
Non-shrinking, double-baked,
neoprene gasketing seals out the
environment.
(For use with HID lamps) Porcelain
socket, copper screwshell, silicone
braid, 150°C.
Housing
Lens
Ballast
Heavy duty, corrosion resistant cast
aluminum housing withstands
impact and environmental abuse.
Standard bronze polyester powder
coat finish.
Nominal 0.156 UV stabilized,
injection molded, impact resistant,
clear prismatic polycarbonate
refractor for high efficiency, low
surface brightness and maximum
strength.
HPF core and coil.
Labels
UL/cUL, standard wet label.
HCS
High Pressure Sodium
Metal Halide
Vandal Resistant
SURFACE
Prismatic Polycarbonate
12 3/4" SQ.
[324mm]
MOUNTING DIMENSIONS
SIDE DIMENSIONS
(4) 5/16" Dia. [8mm]
Mounting Holes
7/8"
[22mm]
7"
[178mm]
9 1/2"
[241mm]
2 1/2"
[64mm]
4 3/16"
[106mm]
7/8"
[22mm]
8"
[203mm]
(4) 1/2" [13mm] Trade Size
Threaded Conduit Fitting
7"
[178mm]
E N E R G Y D ATA
For Energy Management related
technical data to support the
performance of this fixture series,
refer to the ordering information for
input wattage.
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADC041544
2010-05-11 10:24:15
HCS
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : H C S- 1 0 0 S - 2 7 7 - Q R S
Product Family
L a m p Ty p e
3
Vo l t a g e
1
Accessories
(order separately)
Options
HCS
HCS=Cast Aluminum
Surface Luminaire
35S =50W HPS Medium Base 2
50S =50W HPS Mogul Base
70S =70W HPS Mogul Base
100S =100W HPS Mogul Base
150S=150W HPS Mogul Base 4
50M=50W MH Medium Base
70M =70W MH Medium Base
100M =100W MH Medium Base
120=120V
208=208V
240=240V
277=277V
DT=Dual-Tap 120/277V 5
MT=Multi-Tap 120/208/240/277V 6
2
3
4
5
6
PB-120 =Photocell 120V
PB-120 =Photocell 277V
VRSD =T20 Center-pin
tamperproof
TORX®-head bit
2802=Pendant Mounting Box
2811=Trunion Mounting Kit
2822=Quick Mounting Kit
Housing Finishes
Blank=Bronze (Standard)
BLK=Black
WHT=White
NOTES:
1
SF=Single Fuse
DF=Double Fuse
HCA =Pole Mount Adapter: 4” Square Pole
HCB = Wall Mount Adapter Bracket
QRS=Quartz Restrike System
(DC bayonet base; lamp by others)
QS=Quartz Socket Only (DC bayonet base)
WAL =Internal Visor for Wall Mounting
LL=Lamp Included
Products also available in non-US voltages and 50Hz for international markets.
Consult your Cooper Lighting Representative for availability and ordering information.
35S only available with 120V.
All medium base.
Not for use on combustible ceilings.
Not available in 35S.
Not available in 35S or 50S.
P H OTO M E T R I C S
C a n d l e p o w e r D i s t ri b u t i o n
700
1400
2100
Test No. 6580.0
HCS-100S-DUAL
Lamp=S54 (LU100/MED)
No. Lamps=1
Lumens=9500
Spacing Criteria
= 2.4 =1.1
Efficiency=42.0%
2800
Candlepower
Zonal Lumen Summary
Deg.
0
5
15
25
35
45
55
65
75
85
90
Zone
0-30
0-40
0-60
0-90
90-180
0-180
719
739
805
729
763
1178
2354
1231
345
84
73
719
715
649
581
435
433
389
232
91
37
36
Lumens
605
1003
2636
3737
268
4005
%Lamp
6.4
10.6
27.8
39.3
2.8
42.2
%Luminaire
15.1
25.1
65.8
93.3
6.7
100.0
3500
C o e f fi c i e n t o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
10
50
10
50
10
0%
0
50
50
50
50
48
48
48
45
45
45
43
41
39
42
40
38
39
37
41
37
34
31
36
33
31
34
30
37
32
28
25
31
28
25
29
24
33
28
24
21
27
23
20
25
20
30
24
20
16
23
19
16
22
16
27
21
16
13
20
16
13
19
13
24
18
14
11
18
14
11
17
11
22
16
12
09
16
12
09
15
09
20
14
10
08
14
10
08
13
07
19
13
09
07
12
09
07
12
06
rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
43
37
32
28
24
21
18
16
14
12
11
43
35
29
23
19
15
13
10
09
07
06
40
35
30
26
23
19
17
15
13
12
11
40
34
28
23
19
15
12
10
08
07
06
39
33
36
22
18
14
11
09
08
06
05
70
50
80%
30
10
50
70%
30
50%
10
50
30%
10%
Specifications and dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADC041544
2010-05-11 10:24:15
Download