FAIL-SAFE

advertisement
FAIL-SAFE
®
DESCRIPTION
Fail-Safe designed the HUS in wattages up to 100W Metal Halide as an
unbreakable replacement answer to commercial fixtures which might
succumb to vandalism. A corrosion-resistant cast aluminum housing
holds a polycarbonate diffuser which fastens with four tamper-resistant
screws to prevent unauthorized access. Double gasketing seals out the
environment. The HUS is specifically designed for use in public access
areas where vandalism may occur. Ideal for building perimeters, parking
structures, corridors, stairwells, schools and dormitories.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Fa s te n e r s
Captive, stainless steel
tamperproof TORX® -head screws
prevent unauthorized access.
Housing
Heavy duty, corrosion resistant cast
aluminum housing withstands
impact and environmental abuse.
Standard bronze polyester powder
coat finish.
Lens
S o cke t
Nominal 0.156 UV stabilized,
injection-molded, impact-resistant,
clear K12 prismatic polycarbonate
refractor for high efficiency, low
surface brightness and maximum
strength.
(For use with HID lamps) Porcelain
socket, copper screwshell, silicone
braid, 150°C.
R e f l e c to r
Labels
Die-formed CRS. White polyester
powder coat finish.
UL/cUL listed, standard wet label.
Ballast
HPF core and coil.
G a s ke t
Non-shrinking, double baked
neoprene gasketing seals out the
environment.
HUS
High Pressure Sodium
Metal Halide
Vandal Resistant
SURFACE
Clear Prismatic
Polycarbonate
12 3/4" SQ.
[324mm]
MOUNTING DIMENSIONS
SIDE DIMENSIONS
(4) 5/16" Dia. [8mm]
Mounting Holes
7/8"
[22mm]
8 1/2"1
[216mm]
9 1/2"
[241mm]
2 1/2"
[64mm]
4 3/16"
[106mm]
7/8"
[22mm]
8 1/2" 1
[216mm]
8"
[203mm]
1
(4) 1/2" [13mm] T rade Size
Threaded Conduit Fitting
175W Unit=9 3/8" Depth
E N E R G Y D ATA
Electronic Ballast Data
Consult Cooper Lighting Representative
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADC041545
2012-01-09 14:28:34
HUS
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : H U S- 1 0 0 S - 2 7 7 - Q R S
Product Family
Vo l t a g e
L a m p Ty p e
2
Accessories
(order separately)
Options
HUS
HUS=Cast Aluminum
Surface Luminaire
50S=50W HPS Mogul Base
70S=70W HPS Mogul Base
100S=100W HPS Mogul Base
150S=150W HPS Mogul Base 1
50M=50W MH Medium Base
Notes:
70M=70W MH Medium Base
100M=100W MH Medium Base
120=120V
208=208V
240=240V
277=277V
DT=Dual-Tap
120/277V
MT=Multi-Tap
120/208/240/277V
SF=Single Fuse
DF=Double Fuse
OPL=Opal Diffuser
QRS=Quartz Restrike System
(DC bayonet base;
lamp by others)
QS=Quartz Socket Only
(DC bayonet base)
LL=Lamp Included
9210=Photocell (for 120V Only)
9220=Photocell (for 208V, 240V, 277V)
VRSD =T20 Center-pin tamperproof TORX®-head bit
2802=Pendant Mounting Box
2811=Trunion Mounting Kit
2822=Quick Mounting Kit
Housing Finishes 3
Blank=Bronze (Standard)
BLK=Black
WHT=White
VSR =Visor
1
2
Not for use on combustible ceilings.
Products also available in non-US voltages and 50Hz for international
markets. Consult your Cooper Lighting Representative for availability
and ordering information.
3 If visor option is specified, visor is same color as housing.
P H OTO M E T R I C S
C a n d l e p o w e r D i s t ri b u t i o n
275
450
675
Test No. 1313
HUS-100S
Lamp=S54 SB-100
No. Lamps=1
Lumens=9500
Spacing Criteria
=.99 =.99
Efficiency=53.0%
900
Candlepower
Zonal Lumen Summary
Deg.
0
5
15
25
35
45
55
65
75
85
90
Zone
0-30
0-40
0-60
0-90
90-180
0-180
1085
1067
1002
746
739
856
826
754
660
552
477
1085
1097
1015
842
817
838
758
593
427
314
278
Lumens
771
1217
2505
4625
422
5047
%Lamp
8.1
12.8
26.4
48.7
4.4
53.1
%Luminaire
15.3
24.1
49.6
91.6
8.4
100.0
1125
C o e f fi c i e n t o f U t i l i z a t i o n
rc
rw
RCR
1
2
3
4
5
6
7
8
9
10
10
50
10
50
10
0%
0
54
50
47
44
48
45
43
45
40
48
42
37
33
41
36
33
38
31
43
36
31
27
35
30
26
33
25
39
32
26
22
31
26
22
29
21
36
28
23
19
27
22
18
25
18
33
25
20
16
24
19
15
23
15
30
22
17
13
21
17
13
20
13
28
20
15
12
19
15
12
18
11
26
18
13
10
18
13
10
17
10
24
17
12
09
16
12
09
15
09
rc=Ceiling reflectance, rw=W all reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
42
36
31
27
24
21
19
17
16
14
38
30
24
20
17
14
12
11
10
08
40
33
29
25
22
20
18
16
15
14
36
28
23
19
16
14
12
10
09
08
35
27
21
18
15
13
11
09
08
07
70
50
80%
30
10
50
70%
30
50%
10
50
30%
10%
Specifications and dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADC041545
2012-01-09 14:28:34
Download