Aluminum Low-Bay<<<INDUSTRIAL 250W PULSE START METAL HALIDE [ELECTRONIC] BE Vertimark II L O W - B AY I N D U S T R I A L L U M I N A I R E Powered Surface 12 1/2" [318mm] by technology Pendant 13 1/4" [337mm] 17" [432mm] A P P L I C AT I O N Durable construction and dependable performance make the Vertimark II perfect for parking garages. U.L. listed and CSA certified for indoor applications. Optional U.L. wet location listing available. LUMARK® specifications DESCRIPTION The Vertimark II delivers horizontal and vertical footcandles to evenly illuminate low mounting areas such parking garages or storage facilities areas. The combination die-cast reflector/ ballast housing makes Vertimark II economical. Modular assembly makes installation easy and quality construction ensures years of consistent performance. U.L. listed and labeled for damp location. CSA Certified. Wet location optional. T E C H N I C A L D ATA 40°C Ambient Environment (ECONTM Electronic Pulse Start MH) 90°C Supply Wire Rating > PENDANT MOUNTING Standard quick mounting plate for 3/4" IPS conduit frees both hands to complete wiring. > HOUSING Die-cast aluminum housing has durable white polyester powder coat finish. E N E R G Y D ATA Electronic Ballast Input Watts > REFRACTOR HINGE Hinged refractor permits relamping without removal of refractor. 250W MD Electronic (275 Watts) > REFRACTOR Acrylic prismatic refractor controls light for high vertical and horizontal footcandles. > BALLAST ECONTM electronic ballast technology delivers longer lamp life and improved lumen output while maintain constant lamp wattage. End of life circuitry prevents high voltage H.I.D. lamps minimizing non-passive lamp failures. Color shift minimized though improved starting and operations. Thermal monitoring circuitry prevents abnormal high ambient conditions damage to the ballast. Minimum starting temperature is –40°C (-40°F). > OPTIONAL J-BOX MOUNTING Optional factory drilled holes fits a standard 3 1/4" and 4" J-Box for outlet box or surface mounting. Standard 3/4" conduit mounting. O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: MDBE-5A-250-E1-LL LAMP TYPE SERIES MD=Pulse BE=Vertimark II Start Metal Halide (ECONTM Electronic) LENS TYPE 2A=Type II 5A=Type V 2P=Type II Polycarbonate 1 5P=Type V Polycarbonate 1 LAMP WATTAGE 250=250W VOLTAGE 2 120=120V 208=208V 240=240V 277=277V E1=Electronic 120-277V LAMP LL=Lamp Included OPTIONS + ACCESSORIES 3 (See ECONTM Options + Accessories Capabilities Matrix ADH060390) NOTES: 1 Not recommended for use with Metal Halide lamps due to to rapid yellowing typical of polycarbonate material. 2 Products also operate in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 3 Must be listed in order shown and separated by a dash. STANDARD EZ123 MOUNTING Once in place, the EZ123 readily accepts the mating half of the hinge and the fixture is easily attached. ADH060775 B E VERTIMARK II PHOTOMETRICS 90° Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw 50 30 10 50 30 RCR 1 85 80 75 82 77 2 72 65 58 69 62 3 61 53 46 59 51 4 52 43 36 50 42 5 45 36 29 43 34 6 40 31 24 38 30 7 35 26 20 34 25 8 31 23 17 30 22 9 28 20 15 27 20 10 25 17 12 24 17 5 10 15 60° 20 25 30 30° 35 40 45 50 CP/100 Spacing Criterion 1.7 Zone %Lamp Zone 0-30 10.12 0-90 0-40 16.69 90-180 0-60 41.74 Total M H B E - 5 A - 1 7 5 H - M T- L L 175-Watt MH 14,000-Lumen Clear Lamp 10 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 73 56 44 35 28 23 19 14 14 12 75 64 44 46 40 35 31 28 25 22 70 59 50 42 36 32 29 26 23 21 64 54 46 39 33 29 26 23 21 19 56 44 34 27 21 17 14 12 10 8 72 58 54 39 32 28 24 21 18 16 68 53 48 33 26 22 18 16 14 11 66 54 44 36 30 26 22 19 17 15 63 50 40 31 25 21 17 15 13 10 62 50 41 33 28 24 21 18 16 14 59 47 37 29 23 19 16 14 12 10 Candlepower Degree CP 0 1651 5 1463 15 1362 25 1772 35 1388 45 1595 55 2087 65 3456 75 1020 85 810 90 637 %Lamp 76.90 13.16 90.05 L A M P M O R T A L I T Y A N D L U M E N M A I N T E N A N C E C O M PA R I S O N S LAMP MORTALITY LUMEN MAINTENANCE COMPARISONS 100 100 90 80 90 60 80 50 % Lumens % Lamp Survival 70 40 30 20 70 60 10 0 50 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000 Lamp Life [Hours] Natural White TM & Uni-Form ® Pulse Start on ECON TECHNOLOGY Uni-Form ® Pulse Start on CWA Probe Start Metal Halide on CWA 40 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 Lamp Life [Hours] ® 90% Mean Lumens Natural WhiteTM-ECON 86% Mean Lumens Uni-Form Pulse Start-ECON 75% Mean Lumens Uni-Form ® Pulse Start-CWA 65% Mean Lumens-Probe Start Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE® L A M P O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: EQ250-E-BU-C-MG-E28-C-60-C-U LAMP TYPE EQ=ECONTM Quartz Metal Halide 1 WATTAGE 250 LUMINAIRE RATING O=Open E=Enclosed BURN POSITION BU=Base Up Standard (+/- 15°) CLEAR/ COATED C=Clear D=Diffused/ Coated BASE TYPE MG=Mogul E39 MR=Mogul Restricted EX39 2 BULB TYPE E28=ED/BT28 3 LAMP MANUFACTURER 3 C=Common Cooper V=Venture CRI 70=70-79 60=60-69 LAMP COLOR 4, 5 C=Cooper Common 6 35=3500-3900K 40=4000-4400K FEATURES U=UV Coated Z=No Extra Features NOTES: 1 ECONTM Quartz Metal Halide must be approved lamp suppliers. 2 Requires specification of open rated lamp in conjunction with restricted base. 3 Specifying Lamp manufacturer selections other than Cooper Common require CRI, Lamp color and feature category to be completed. 4 Where lamp temperature is specific, enter first two digits of kelvin. 5 Kelvin temperature callout is provided for a general range of correlating temperature. EXAMPLE: 40 will range from 4000-4200K CCT. 6 Common is 4K. NOTE: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH060775