INSTALLATION INSTRUCTIONS V90313-1T COMBO HO WW TRIMMED REMODEL Avoid Fire or Electric Shock Sheet 1 of 3 *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. *Fixtures to be wired as follows: Black wire to incoming line voltage; White wire to common; Green wire to building ground. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. FIXTURE MOUNTING: 1. First remove TRIM, WIRING ENCLOSURE, and MOUNTING CLIPS from HOUSING. See Fig 1. HOUSING HOUSING WIRING ENCLOSURE WIRING ENCLOSURE (REMOVE) Figure 1 TORSION SPRING Figure 3 MOUNTING CLIPS - 4X (REMOVE) CEILING MATERIAL INSTALLATION: TRIM (REMOVE) 6. Replace the TRIM into the HOUSING by connecting the TORSION SPRINGS to the HOUSING. Push the TRIM into the HOUSING until flush with the CEILING as seen in Figure 4. 2. A clean, square hole in the CEILING must be cut (see spec sheet for dimensions). Place HOUSING into the CEILING. One at a time, place the MOUNTING CLIPS into the HOUSING through the T-slot provided. The MOUNTING CLIPS should be lowered into position (See Fig 2) until the CEILING is sandwiched between the clip and the HOUSING. Tighten the screw on the MOUNTING CLIP to secure the HOUSING. Repeat with the three remaining MOUNTING CLIPS. HOUSING SCREW HOUSING CEILING Figure 2 MOUNTING CLIP ELECTRICAL: 3. Separate WIRING ENCLOSURE by removing attached nuts. Connect supply lead wires to WIRING ENCLOSURE lead wires thru Knockout in accordance with your local eletrical code(s) or N.E.C. Fasten WIRING ENCLOSURE by securing with NUTS. INSTALLATION NOTE: DO NOT install insulation within 3in of any part of the Luminaire. Blinking light of this thermally protected Luminaire may indicate overheating. 4. Replace the WIRING ENCLOSURE into the HOUSING by pushing through and snapping into side wall of HOUSING. See Fig 3. 5. Connect Quick-Connect Electrical Connectors from Wiring Enclosure and the Stasis HO WW module in the TRIM. TRIM CEILING Figure 4 INSTALLATION INSTRUCTIONS V90313-2 COMBO HO WW REMODEL Avoid Fire or Electric Shock Sheet 2 of 3 *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. *Fixtures to be wired as follows: Black wire to incoming line voltage; White wire to common; Green wire to building ground. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. AIMING: 1. To aim the Stasis HO WW, start by loosening both SET SCREWS in the lockable ROTATION BUSHINGS with a HEX WRENCH. 3. Once aiming is complete, lock the STASIS HO module into place by tightening the two set screws in the ROTATION BUSHINGS with a HEX WRENCH. STASIS HO MODULE SET SCREWS IN ROTATION BUSHINGS Figure 1 STASIS HO MODULE HEX WRENCH Figure 3 2. Adjust the STASIS HO module to the desired aiming angle by pulling straight down. HOUSING CEILING MATERIAL Figure 2 SET SCREW IN ROTATION BUSHING STASIS HO MODULE INSTALLATION INSTRUCTIONS V90313-3T REMODEL Avoid Fire or Electric Shock Sheet 3 of 3 *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. *Fixtures to be wired as follows: Black wire to incoming line voltage; White wire to common; Green wire to building ground. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. ACCESSING THE ELECTRICAL SYSTEM: 1. To service the Electrical System (change driver) for fixtures with a TRIM, pull straight down on the TRIM and compress TORSION SPRINGS to release the TRIM from the HOUSING. HOUSING WIRING ENCLOSURE Figure 1 STASIS HO WW MODULE TORSION SPRING TRIM 2. Disconnect the STASIS HO WW MODULE by disconnecting the Electrical Connectors from the Housing/Electrical and the STASIS HO WW MODULE in the TRIM. 3. Remove the WIRING ENCLOSURE from the HOUSING SIDE WALL by pulling directly on electrical wiring. The WIRING ENCLOSURE will release from HOUSING SIDE WALL, allowing it to be pulled through the housing opening for maintenance. HOUSING HOUSING SIDE WALL CEILING MATERIAL Figure 2 COMBO HO WW WIRING ENCLOSURE (wiring and electrical connectors not shown) 4. When servicing is finished, place WIRING ENCLOSURE into the HOUSING against the HOUSING SIDE WALL and push until it 'snaps' into place. Make sure that all wiring is tucked into place when doing this - failure to do so may result in bad connections or failure to place the WIRING ENCLOSURE onto the HOUSING SIDE WALL. 5. Connect Electrical Connectors from Housing/Electrical and the STASIS HO WW Module in the TRIM. 6. Replace the TRIM into the HOUSING by connecting the TORSION SPRINGS to the HOUSING. Push the TRIM into the HOUSING until flush with the CEILING MATERIAL.