INSTALLATION INSTRUCTIONS COMBO HO WW V90313-1T TRIMMED REMODEL

advertisement
INSTALLATION INSTRUCTIONS
V90313-1T
COMBO HO WW
TRIMMED REMODEL
Avoid Fire or Electric Shock
Sheet 1 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
*Fixtures to be wired as follows:
Black wire to incoming line voltage;
White wire to common;
Green wire to building ground.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
FIXTURE MOUNTING:
1. First remove TRIM, WIRING ENCLOSURE, and MOUNTING CLIPS from
HOUSING. See Fig 1.
HOUSING
HOUSING
WIRING
ENCLOSURE
WIRING ENCLOSURE
(REMOVE)
Figure 1
TORSION
SPRING
Figure 3
MOUNTING CLIPS - 4X
(REMOVE)
CEILING MATERIAL INSTALLATION:
TRIM
(REMOVE)
6. Replace the TRIM into the HOUSING by connecting the TORSION
SPRINGS to the HOUSING. Push the TRIM into the HOUSING until flush with
the CEILING as seen in Figure 4.
2. A clean, square hole in the CEILING must be cut (see spec sheet for
dimensions). Place HOUSING into the CEILING. One at a time, place the
MOUNTING CLIPS into the HOUSING through the T-slot provided. The
MOUNTING CLIPS should be lowered into position (See Fig 2) until the
CEILING is sandwiched between the clip and the HOUSING. Tighten the
screw on the MOUNTING CLIP to secure the HOUSING. Repeat with the
three remaining MOUNTING CLIPS.
HOUSING
SCREW
HOUSING
CEILING
Figure 2
MOUNTING CLIP
ELECTRICAL:
3. Separate WIRING ENCLOSURE by removing attached nuts. Connect
supply lead wires to WIRING ENCLOSURE lead wires thru Knockout in
accordance with your local eletrical code(s) or N.E.C. Fasten WIRING
ENCLOSURE by securing with NUTS.
INSTALLATION NOTE:
DO NOT install insulation within 3in of any part of the Luminaire. Blinking light
of this thermally protected Luminaire may indicate overheating.
4. Replace the WIRING ENCLOSURE into the HOUSING by pushing through
and snapping into side wall of HOUSING. See Fig 3.
5. Connect Quick-Connect Electrical Connectors from Wiring Enclosure and
the Stasis HO WW module in the TRIM.
TRIM
CEILING
Figure 4
INSTALLATION INSTRUCTIONS
V90313-2
COMBO HO WW
REMODEL
Avoid Fire or Electric Shock
Sheet 2 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
*Fixtures to be wired as follows:
Black wire to incoming line voltage;
White wire to common;
Green wire to building ground.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
AIMING:
1. To aim the Stasis HO WW, start by loosening both SET SCREWS in the
lockable ROTATION BUSHINGS with a HEX WRENCH.
3. Once aiming is complete, lock the STASIS HO module into place by
tightening the two set screws in the ROTATION BUSHINGS with a HEX
WRENCH.
STASIS HO
MODULE
SET SCREWS
IN ROTATION
BUSHINGS
Figure 1
STASIS HO
MODULE
HEX WRENCH
Figure 3
2. Adjust the STASIS HO module to the desired aiming angle by pulling
straight down.
HOUSING
CEILING
MATERIAL
Figure 2
SET SCREW
IN ROTATION
BUSHING
STASIS HO
MODULE
INSTALLATION INSTRUCTIONS
V90313-3T
REMODEL
Avoid Fire or Electric Shock
Sheet 3 of 3
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
*Fixtures to be wired as follows:
Black wire to incoming line voltage;
White wire to common;
Green wire to building ground.
THIS PRODUCT MUST BE INSTALLED IN
ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
ACCESSING THE ELECTRICAL SYSTEM:
1. To service the Electrical System (change driver) for fixtures with a TRIM,
pull straight down on the TRIM and compress TORSION SPRINGS to
release the TRIM from the HOUSING.
HOUSING
WIRING
ENCLOSURE
Figure 1
STASIS HO WW
MODULE
TORSION
SPRING
TRIM
2. Disconnect the STASIS HO WW MODULE by disconnecting the Electrical
Connectors from the Housing/Electrical and the STASIS HO WW MODULE
in the TRIM.
3. Remove the WIRING ENCLOSURE from the HOUSING SIDE WALL by
pulling directly on electrical wiring. The WIRING ENCLOSURE will release
from HOUSING SIDE WALL, allowing it to be pulled through the housing
opening for maintenance.
HOUSING
HOUSING
SIDE WALL
CEILING
MATERIAL
Figure 2
COMBO HO WW
WIRING
ENCLOSURE
(wiring and electrical connectors not shown)
4. When servicing is finished, place WIRING ENCLOSURE into the HOUSING
against the HOUSING SIDE WALL and push until it 'snaps' into place.
Make sure that all wiring is tucked into place when doing this - failure to do
so may result in bad connections or failure to place the WIRING
ENCLOSURE onto the HOUSING SIDE WALL.
5. Connect Electrical Connectors from Housing/Electrical and the STASIS HO
WW Module in the TRIM.
6. Replace the TRIM into the HOUSING by connecting the TORSION
SPRINGS to the HOUSING. Push the TRIM into the HOUSING until flush
with the CEILING MATERIAL.
Download