INSTALLATION INSTRUCTIONS
ANY ISSUES WITH INSTALLATION REQUIRES IMMEDIATE CALLS TO
SHAPER
N
IN WALL
BLOCKING
LED
DRIVER
FIXTURE
MOUNT
PLATE
HOOK
AND
TAB
CL OF FIXTURE
MOUNT PLATE
LED
MODULE
FIXTURE
MOUNT
PLATE
JBOX CL
CAUTION:
14 1/2" = 36"
9 3/8" = 24"
6 3/8" = 18"
BLOCKING
DISTANCE
36"=35 3/8"
24"=23 5/8"
18"=17 5/8"
CAPTIVE SCREW
TIGHTENS HERE
LED MODULE
WALL
(4) #8 WOOD
SCREWS
MOUNT PLATE
PULL AC SOURCE
WIRING THRU
HERE
For proper installation, a qualified
electrician should install this product.
Before installation of any luminaire onto an
electrical junction box, be sure to disconnect power.
This luminaire must be wired and grounded in
accordance with the National Electrical Code, local
codes, and ordinances.
Wire supply connections must be made with UL
approved connectors.
Confirm that luminaire and supply voltage
are the same.
Junction box provided by others with means of
supporting minimum 50 lbs.
Supply wire to be rated for 90 C.
This fixture is UL listed for dry or damp location only.
BLOCKING
DETAIL N
SCALE 1 : 6
OCTAGONAL
ELECTRICAL
JUNCTION BOX
(BY OTHERS)
FIXTURE WEIGHT APPROXIMATELY 5 LBS.
CONTRACTOR IS REQUIRED TO PROVIDE
866-XX
APPROPRIATE STRUCTURAL SUPPORT
FOR FIXTURE TO MEET LOCAL CODE REQUIREMENTS.
EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND
SERVICING LUMINAIRE.
USE OF SOFT GLOVES AND PADDED MATERIALS ARE
RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH.
COMPONENTS MAY BE CLEANED WITH SOFT DAMP OR DRY CLOTH.
INSTRUCTIONS:
1. Disconnect electrical lighting circuit at breaker panel.
2. Locate wire hole on Fixture Mount Plate and center over
electrical junction box.
3. Secure Fixture Mount Plate to blocking in wall with (4) #8 wood screws.
4. Pull and expose source AC wiring thru wire hole in Fixture Mount Plate
from electrical junction box.
5. Wiring Fixture to source AC wiring, using UL listed wire connectors:
connect the neutral (white) wire to the supply neutral,
connect the luminaire line wire (black) to the supply line wire,
connect the ground (green) wire to the supply ground.
6. Wiring Fixture 0-10V dimming to source dimming wiring, using
UL listed wire connectors:
connect the fixture violet wire to the dimmer violet wire,
connect the fixture gray wire to the dimmer gray wire,
if driver thermal sensing is used, connect fixture orange wire to
thermal sensing device.
7. Inspect wire connections before installing LED Module.
8. Feed as much wiring as possible wiring back into electrical junction box.
Avoid pinching or breaking wires.
9. Carefully install LED Module to Fixture Mount Plate by hooking
LED Module over tab on Fixture Mount Plate.
10. Make sure LED Module is fully seated on Fixture Mount Plate and Diffuser.
11. Tighten captive screw at opposite end of fixture
to secure LED Module against wall.
12. Restore power to lighting circuit and test installation.