Metalux D ES C R IPTION Type Catalog # The Paralux III Modular Series features the latest in energy efficient technology. The luminaire incorporates a true 3" deep precision cell louver into a nominal 6-11/16" modular fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The series is available with a number of options and accessories for application versatility. The high performance luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. The Paralux III series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n Nominal 6-11/16" housing die formed of code gauge prime cold rolled steel. Smooth sides permit flush joint for continuous row mounting. Full seam welded corners. Dihedral recessed top design insures cooler ballast operation. Die formed captive lampholder bracket fully encloses wiring permitting easy lampholder replacement. Ballast/wireway covers removed without tools. mounting bolts. Pressure lock lampholders. UL/CUL listed. hinging. Safety chains provided. Suitable for damp locations. F in ish Louver Painted after fabrication. Electrostatically applied baked white polyester powder enamel finish. Multistage cleaning cycle, iron phosphate coating with rust inhibitor. Conveyorized application and baking timing accurately controlled at an elevated temperature. Die formed of low iridescent, vertical grain aluminum. Finish is Anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. El e c t r i c a l * Hin g in g /L a tch ing Ballasts are CBM/ETL Class “P” and are positively secured by Positive cam action spring loaded, self locking, steel latches. Positive 6-11/16" [170mm] 2EP3MX 232 332 432 12, 18 or 32 Cell 2' X 4' PARABOLIC 2, 3 OR 4 T8 LAMP SEMI-SPECULAR OR SPECULAR LOUVER Paralux III Surface Modular 24" [610mm] MOUNTING D A TA ST E M MOUNT ING D A T A 3/8" [10mm] K.O. (2) 11/16" [17mm] K.O. (4) 7/8" [22mm] K.O. (5) 4 Point Suspension Utilizes Standard KOs (Consult Pre Sales Technical Support.) ENERGY DATA Consult Pre Sales Technical Support for Continuous Row Application. 21-1/8" [537mm] 24" [610mm] Single Fixture Application 1-1/4" [32mm] L A MP CONF IGURA T IONS ES Ballast & STD Lamps 232 (71), 332 (108), 432 (142) 2 LAMP 36-7/16" [926mm] 38-15/16" [989mm] 41" [1041mm] 48" [1219mm] 6-11/16" [170mm] 10-3/16" [259mm] 24" [610mm] 2-11/16" [69mm] 11/16" [17mm] K.O. (4) 3 LAMP 6-11/16" [143mm] 21-1/8" [537mm] 24" [610mm] 3-1/2" [89mm] 1-1/4" [32mm] 2-11/16" [69mm] 7" 7" [178mm] [178mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 4 LAMP 6-11/16" [170mm] 38-15/16" [989mm] 48" [1219mm] Luminaire Efficacy Rating LER = FP-56 Catalog Number: 2EP3MX-232 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.29 24" [610mm] 7/8" [22mm] K.O. (5) 36-7/16" [926mm] Input Watts: EB Ballast & STD Lamps 232 (61), 332 (91), 432 (122) 2-11/16" [69mm] X=4-13/16" [122mm] X 5-3/4" X [146mm] Safe and convenient means of disconnecting power. 24" [610mm] ADF020573 2015-10-15 12:03:48 PHOTOM ETR IC S 2 EP3 M X Coefficients of Utilization 2EP3MX-232S26I Electronic Ballast F32T8/35K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.8 x mounting height Efficiency 67.7% Test Report: 2EP3MX232S26I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 81 75 70 65 60 55 51 46 43 39 36 81 73 65 59 53 47 42 38 34 30 27 81 71 62 54 48 42 37 32 28 25 22 81 69 59 51 44 38 33 28 24 21 18 79 74 68 63 58 53 49 45 42 38 35 79 71 64 58 52 46 42 37 33 30 27 79 69 61 54 47 41 36 32 28 25 22 79 67 58 50 43 37 33 28 24 21 18 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 75 69 62 56 50 45 40 36 32 29 26 72 66 60 54 49 44 39 35 32 28 26 69 64 58 52 47 42 38 34 31 28 25 68 60 53 46 40 35 30 26 23 19 17 75 67 59 52 46 40 36 32 28 24 22 75 65 57 49 43 37 32 28 24 21 18 72 65 58 51 45 40 35 31 27 24 21 72 63 55 48 42 37 32 28 24 21 18 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1136 1982 3415 3793 3793 20.3 35.4 61.0 67.7 67.7 30.0 52.3 90.0 100.0 100.0 Height Along 8.5’ 10.0’ 81 80 86 84 88 87 87 86 89 89 69 62 56 50 44 39 35 31 27 24 21 69 62 54 48 42 36 32 28 24 21 18 Height Across 8.5’ 10.0’ 76 77 83 80 86 84 84 83 87 86 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1372 1359 1333 1294 1242 1179 1107 1024 930 823 704 575 422 238 81 26 11 3 0 45° 1372 1372 1366 1357 1343 1333 1330 1327 1313 1293 1126 694 375 272 152 35 12 4 0 Across ⊥ 1372 1385 1400 1420 1462 1524 1586 1722 1782 1208 585 478 500 410 307 38 16 5 0 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.29 OR D ER ING INFOR M A TION SAMPLE NUMBER: 2EP3MX-232S26I-120V-EB81-U Width 2=2' Width Options Packaging Ballast Type (1) EKO=7/8" KOs in End of U=Unit Pack EB8 =T8 Electronic Instant Start. 2 Fixture Housing Total Harmonic Distortion < 10% SMB=Side Mounted No. of Ballast Ballast For Stem 1, 2 or 3 Applications EB8 /PLUS= T8 Electronic Instant Start. RLS=Rotor-Lock Socket High Ballast Factor >1.13. (T8 Lamps Only) No. of Total Harmonic Distortion < 10% Ballast (Additional options available. See Accessory Section) 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 Number of Lamps 1, 2 or 3 lamps (Not included) EP=Paralux Louver (III) Louver Depth 3=Paralux III MX=Surface Mount/Floating Louver Wattage (Length) 32=32W Octron T8 (48") Louver Color S=Silver W=White Cell Configuration 26=2 Rows of 6, 12 Cell 36=3 Rows of 6, 18 Cell 48=4 Rows of 8, 32 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Volt (2) NOTES: (1) SH IP P ING D A T A (2) Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Catalog No. 2EP3MX-232S26I 2EP3MX-332S26I 2EP3MX-432S26I 2EP3MX-232S36I 2EP3MX-332S36I 2EP3MX-432S36I 2EP3MX-232S48I 2EP3MX-332S48I 2EP3MX-432S48I Wt. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. ADF020573 2015-10-15 12:03:48