VERTX AISLE LIGHTER
Vertical Aisle Lighter High-Bay Luminaire
WAREHOUSE + AISLE
ENVIRONMENTS
As warehouses grow and aisles
become taller and longer, the need
has arisen for a luminaire that can
deliver the horizontal punch while
providing vertical uniformity.
Standard aluminum high-bays can
offer a very narrow distribution
but their symmetric distribution
produces a “scallop” effect of
uneven vertical illumination.
Prismatic acrylic and glass
luminaires provide better vertical
uniformity but at higher mounting
heights it requires more
luminaires to meet the horizontal
luminance requirements.
OPTIMUM PERFORMANCE
The VertX aluminum reflector
was designed to address the
shortcomings of typical high-bay
luminaires by offering an
asymmetrical distribution for
better vertical uniformity but with
a strong downward punch to meet
the high horizontal lighting
requirements. Unlike traditional
high-bays that produce a
symmetrical distribution, the VertX
was designed specifically to fit the
long narrow warehouse aisles that
are most common today.
ENERGY SAVINGS
OPPORTUNITIES
This distribution allows the
luminaires to be spaced further
apart and deliver higher horizontal
light levels versus traditional
products, or use the same number
and reduce the lamp wattage of
luminaires for higher vertical
uniformity and equivalent
horizontal illumination. For the
ultimate in energy and
maintenance savings, combine
the VertX with Cooper Lighting’s
ECONTM electronic H.I.D. ballast
and LumaWatt Hi/Lo control
systems. The VertX aisle lighter
is the H.I.D. solution to meet
today’s challenging warehousing
designs.
Powered
by
technology
ECONTM is available only in the Benchmark housing. >>>
Typical High-bays vs. the VertX
HORIZONTAL
AVG.
FIXTURE TYPE
QTY.
REQ.
MAX.
MIN.
Aluminum High-Bay
11
Acrylic High-Bay
14
30.25
33.8
30.82
33.6
VertX
10
33.6
Acrylic/Aluminum
18
16
VERTICAL
MAX./MIN.
AVG.
MAX.
MIN.
MAX./MIN.
15.4
2.19
19.1
1.76
17.5
59.6
2.9
20.55
18.1
56.1
3.4
39.5
16.7
16.5
2.37
15.5
36.8
3.1
11.87
29.97
35.1
12.2
2.88
20.1
55.8
2.3
24.26
30.5
34.6
18.6
1.86
20.8
54.7
3.1
17.65
Aislelighter
Modified Aluminum
High-Bay Aisleligher
AISLE:...........................8'10" x 200' x 32'
MOUNTING HEIGHT:.....30'
RACKS:.........................25'
REFLECTANCE:.............Ceiling: 50%, Aisle: 0%, Wall 10%
• HORIZONTAL REQUIREMENTS—Fewer fixtures.
• VERTICAL REQUIREMENTS—Same number of fixture with lower wattage.
1 Indoor Lighting Solutions
HB VertX
Cooper Lighting
Specification Features
REFLECTOR
The VertX is a hydroformed aluminum reflector scientifically
designed with multiple facets to produce a long narrow
distribution to provide the right balance of horizontal and
vertical illumination. Rigid construction and an anodized
finish ensure consistent optical performance. The bottom of
the VertX reflector is symmetrical to allow easy installation
of safety glass lens or wire guard accessories.
LAMP
The VertX was designed to use clear HID lamps for
maximum lumen output and performance. The vertical lamp
orientation delivers higher lumen output and longer lamp
life. Requires mogul-base 175-450W Metal Halide or
250-400W High Pressure Sodium lamps.
EB E&G VertX
HOUSING + BALLAST
The VertX reflector assembles easily to either the Steeler or
Benchmark housings. AV19 reflector mounts easily to the
ladder bracket assembly or die-cast neck and distributions
can be adjusted for precise control. The ENVA19 is provided
with a die-cast aluminum neck and provides for a wide
range of distributions from concentrated to wide. Both the
Steeler and Benchmark ballast housings are available with
magnetic or ECONTM electronic HID ballast. The ECONTM
offers Electronic HID ballast superior lamp maintenance
and its 0-10V variable dimming capability make it ideal for
warehousing applications.
MOUNTING
Steeler and Benchmark housings ship standard with an
easy slide-on die-cast aluminum mounting box with a
tapped opening for 3/4" conduit. Hook, cord and plugs,
remote connections, Thru-Way power and pendant hooks
are available. All products are also available with MWS
modular wiring. MWS installs in 1/3 of the time as conduit
and MC cable and offers great flexibility to address future
building changes.
SS VertX
L U M AW AT T [ I N D I V I D U A L F I X T U R E C O N T R O L ]
LumaWatt motion detector works in
conjunction with fixture dimmers to
provide bi-level control based on an
area’s occupancy. Motion detector is
passive infrared type and reacts to
changes in infrared energy (heat)
within the coverage area.
LumaWatt individual fixture controls
are the perfect solution for warehouse
and storage area retrofit opportunities.
Wiring is integrated directly to the
housing without the need to run
additional control wires throughout
the facility.
SE E&G VertX
Cooper Lighting
HSW or LSW Option
Indoor Lighting Solutions
2
INDUSTRIAL>>>Aluminum High-Bay
SS VertX
150-450W
HP/MH/MP/ML
V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E
26 7/8" [683mm]
A P P L I C AT I O N
The SS VertX aisle lighter is ideal for higher
mounting height warehouse applications.
Its unique distribution pattern delivers high
horizontal illumination while reducing
“scallops” or hot spots for a more uniform
vertical surface.
19" [483mm]
LUMARK®
MOUNTING
O R D E R I N G I N F O R M AT I O N
Easy slide-on die-cast aluminum
S A M P L E N U M B E R : M H S S - A V 1 9 - M - 4 0 0 - M T- Q
mounting box with tapped opening
for 3/4" conduit.
HOUSING
Heavy-duty, formed steel housing
LAMP TYPE
SERIES
REFLECTOR TYPE
HP=High
SS=Steeler
AV=VertX
Pressure
Sodium 1
MH=Metal Halide 2
MP=Pulse Start MH (CWA) 2, 3
ML=Pulse Start MH (Linear Reactor) 2, 3, 4
REFLECTOR
DIAMETER
19=19"
with an open air ballast for cooler
operation is finished in a white
polyester powder paint.
BALLAST
High power factor ballast with class
H insulation. Minimum starting
temperature is -40°C (-40° F) for
HPS and -30°C (-20° F) for MH, MP
and ML.
UNIVERSAL BRACKETS
Universal ladder brackets allow for
the flexibility to change out with
other reflectors available in acrylic
or glass.
SOCKET
Mogul-base porcelain socket.
REFLECTOR
Computer-designed, field-adjustable
reflector mounts easily and allows
multiple distribution patterns for
SOCKET POSITION/
DISTRIBUTION 5
C=Concentrated
M=Medium
W=Wide
LAMP WATTAGE
150=150W 6
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
450=450W
VOLTAGE 7
OPTIONS +
120V
ACCESSORIES 11
208V
(See Below)
240V
277V
347V
480V
MT=Multi-Tap 8
TT=Triple-Tap 9
5T=5-Tap 10
OPTIONS + ACCESSORIES
OPTIONS (add as suffix) 11
P=Pre-set Socket Position from the factory
SS=Space Saver Feature
QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3,
MWS, RM or HC)
RM=Remote Mount 12
HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures
outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 13
HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring
all wiring to be installed in conduit) 13, 14
HSW=Integral LumaWatt Sensor and Control with Wide Distribution for CWA Magnetic Ballast 13
Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start)
EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts)
EM/SC=Quartz Restrike wired for Separate Circuit 15
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240, or 480V only)
FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation)
PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P,
and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V
ACCESSORIES (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P,
347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length
(PC6 for 6’ cord). Requires FH-1, FL-1, or SHK
PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage
PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and
TPPH-NEMA (Thru-Way Pendant Power Hook)
TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage
precise control.
PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage.
EXAMPLE: PHC-120V
PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook).
EXAMPLE: PHC-120V-NEMA
C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK)
MW=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and
11 ft. also available. Please refer to MWS Modular Wiring System section for additional information)
SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available.
EXAMPLE: SCF6=6' Cable)
SCR=Aircraft Safety Cable for Housing to Reflector
L/TCB=Less Top Connector Box (Housing shipped less top connector box. Specify when using TWMBS
accessory)
LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped
separate from luminaire unless otherwise noted)
QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is
shipped separate from luminaire unless otherwise noted)
TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage
TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (120, 277, or 347V)
TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (208, 240 or 480V)
TWMBS=Thru-way Mounting Box
C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK
MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs)
WG19/AV=Wire Guard for AV19 (Not compatible with “SGB19”)
SGB19/AV=Safety Glass Bottom for AV19 (Not compatible with “WG19”)
WG19/SGB/AV=Wire Guard with Safety Glass Bottom
S H I P P I N G D ATA
Approximate Net Weight:
33-40 lbs. (15-18 kgs.)
NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass
bottom (SGB) accessory or an open rated socket (OR) and lamp. 3 200, 250, 320, 350, 400 and 450W only. 4 277V only, not available with Q, EM, HL, HC, or HS option. 5 Factory set for concentrated, medium or wide
distributions only if P (factory pre-set) is in the nomenclature of the fixture. 6 HPS only. 7 Products also available in non-US voltages and 50HZ for international markets. 8 Multi-tap ballast 120/208/240/277V wired 277V.
9 Triple-tap ballast 120/277/347V wired 347V. 10 5-tap ballast 120/208/240/277/480V wired 480V. 400W MH only. 11 Must be listed in order shown and separated by a dash. 12 Not available with QD, W, WL options.
13 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA ballast only. 14 Not available with QD PC3, C3, PHC or MWS.
Not available with single circuit MWS special order. 15 Not available with HL or HC option.
3 Indoor Lighting Solutions
Cooper Lighting
Aluminum High-Bay<<<INDUSTRIAL
150-450W
HP/MH/MP/ML/MD
HB VertX
H E AV Y- D U T Y V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E
Powered
by
technology
27" [686mm]
A P P L I C AT I O N
The HB VertX aisle lighter is ideal for higher
mounting height warehouse applications.
Its unique distribution pattern delivers high
horizontal illumination while reducing
“scallops” or hot spots for a more uniform
vertical surface.
19" [483mm]
LUMARK®
O R D E R I N G I N F O R M AT I O N
MOUNTING
S A M P L E N U M B E R : H P H B - A V 1 9 - M - 4 0 0 - M T- Q
Easy slide-on die-cast aluminum
LAMP TYPE
SERIES
REFLECTOR TYPE
HP=High
HB=High-Bay
AV=VertX
Pressure
Benchmark
Sodium 1
MH=Metal Halide 2
MP=Pulse Start MH (CWA) 2, 3
ML=Pulse Start MH (Linear Reactor) 2, 3, 4
MD=Pulse Start Metal Halide (Electronic) 2, 5, 6
REFLECTOR
DIAMETER
19=19"
OPTIONS + ACCESSORIES
SOCKET POSITION/
DISTRIBUTION 7
C=Concentrated
M=Medium
W=Wide
LAMP
WATTAGE
150=150W 8
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
450=450W 9
VOLTAGE 10
OPTIONS +
120V
ACCESSORIES 15
208V 11
(See Below)
11
240V
277V 11
347V
480V
MT=Multi-Tap 12
TT=Triple-Tap 13
5T=5-Tap 14
E=Electronic 11
mounting box with tapped opening
for 3/4" conduit.
HOUSING
Durable heavy-duty die-cast
aluminum housing for lasting
performance in the harshest
environments. Integrally hinged for
ease of maintenance with optional
OPTIONS (add as suffix) 15
P=Pre-set Socket Position from the factory
OR=Open Rated Socket for Metal Halide Lamps
SS=Space Saver Feature
QB=Quiet Ballast (Available on the Benchmark ballast housing only)
QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3,
MWS, RM or HC)
RM=Remote Mount 16
TE=Toolless Entry
HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures
outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 17
HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring
all wiring to be installed in conduit) 17, 18
HSW=Integral LumaWatt Sensor and with Wide Distribution Control for CWA Magnetic Ballast 17
LC=Low Voltage Control (0-10V DC Low voltage leads pulled out of top connection box for areas requiring all
wiring to be installed in conduit. Available with Benchmark housing and electronic HID ballast only—MD
lamp type) 17, 19
LSW=Integral 0-10V Sensor and with Wide Distribution Control for ECONTM Electronic Ballast 17, 19
Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start)
EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts)
EM/SC=Quartz Restrike wired for Separate Circuit 5
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240, or 480V only)
FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation)
PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and
480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V
PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage.
EXAMPLE: PHC-120V-NEMA
PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook).
EXAMPLE: PHC-NEMA
C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK)
MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft.
and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information)
SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available.
EXAMPLE: SCF6=6' Cable)
SCR=Aircraft Safety Cable for Housing to Reflector
L/TCB=Less Top Connector Box (Housing shipped less top connector box. Used when using TWMBS
[Steeler Family] and TW [Benchmark Family] accessories)
LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped
separate from luminaire unless otherwise noted)
QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is
shipped separate from luminaire unless otherwise noted)
toolless entry. Finished in a white
polyester powder coat.
BALLAST
High-power factor ballast with class
H insulation. Minimum starting
temperature is -40°C (-40°F) HPS
and -30°C (-20°F) for MH, MP, ML,
and MD.
UNIVERSAL BRACKETS
Universal ladder brackets allow for
the flexibility to change out with
other reflectors available in acrylic
ACCESSORIES (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P,
347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length
(PC6 for 6’ cord). Requires FH-1, FL-1 or SHK
PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage
PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook)
TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage
TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage
or glass.
TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (120, 277, or 347V)
TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (208, 240 or 480V)
TW=Thru-way Mounting Box
C3=3' Cord-No Plug-Requires FH-1, FL-1 or SHK
MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs)
SOCKET
Mogul-base porcelain socket.
REFLECTOR
Computer aided designed,
field-adjustable reflector mounts
easily and allows multiple
distribution patterns for precise
control. Special contours and
unique system of facets minimizes
NOTES: 1 Not available 175, 200, 320, 350 and 450W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass
bottom (SGB) accessory or an Open rated socket (OR) and lamp. 3 200, 250, 320, 350, 400 and 450W only. 4 277V only, not available with Q or EM option. 5 Not available with HL or HC. 6 320, 350 and 400W only
(See ECON section for list of current approved lamps at www.cooperlighting.com). 7 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 8 HPS only.
9 Standard 55°C ambient environments. 10 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 11 MD available in 208, 240 or 277V or
with “E” option which will operate voltages from 200-277V 50/60 Hz. 12 Multi-tap ballast 120/208/240/277V wired 277V. 13 Triple-tap ballast 120/277/347V wired 347V. 14 5-tap ballast 120/208/240/277/480V wired
480V. 400W Metal Halide. 15 Must be listed in order shown and separated by a dash. 16 Not available with QD, W, WL option. 17 30 second time delay when switching from bright to dim. Consult individual lamp
manufactures recommendations for compatible lamps. For use with CWA or ECONTM ballast only. 18 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 19 Specify when
using MD lamp type only.
Cooper Lighting
arc tube voltage rise.
S H I P P I N G D ATA
Approximate Net Weight:
35 lbs. (15 kgs.)
Indoor Lighting Solutions
4
INDUSTRIAL>>>Aluminum High-Bay
SE E&G VertX
150-450W
HP/MH/MP/ML
E N C L O S E D & G A S K E T E D V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E
31 3/16" [792mm]
A P P L I C AT I O N
The SE E&G VertX aisle lighter is ideal for
higher mounting height warehouse
applications. Its unique distribution pattern
delivers high horizontal illumination while
reducing “scallops” or hot spots for a more
uniform vertical surface.
19" [483mm]
LUMARK®
MOUNTING
O R D E R I N G I N F O R M AT I O N
Easy slide-on die-cast aluminum
S A M P L E N U M B E R : H P S E - E N A V 1 9 - M - 4 0 0 - M T- Q
mounting box with tapped opening
for 3/4" conduit.
HOUSING
Heavy-duty, formed steel housing
with an open air ballast for cooler
operation is finished in a white
LAMP TYPE
SERIES
REFLECTOR TYPE
HP=High
ENAV=Enclosed &
SE=E&G
Pressure
Gasketed
VertX
Sodium 1
VertX
MH=Metal Halide
2
MP=Pulse Start MH (CWA)
ML=Pulse Start MH (Linear Reactor) 2, 3
REFLECTOR
DIAMETER
19=19"
polyester powder paint.
SOCKET POSITION/
DISTRIBUTION 4
C=Concentrated
M=Medium
W=Wide
LAMP
WATTAGE
150=150W 5
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
450=450W
VOLTAGE 6
OPTIONS +
120V
ACCESSORIES 10
208V
(See Below)
240V
277V
347V
480V
MT=Multi-Tap 7
TT=Triple-Tap 8
5T=5-Tap 9
BALLAST
High power factor ballast with class
H insulation. Minimum starting
temperature is -40°C (-40°F) for
HPS and -30°C (-20°F) for MH, MP
and ML.
SOCKET
Mogul-base porcelain socket.
NECK
Die-cast aluminum neck with
staggered mounting bosses for
eight-position adjustability of the
socket which provides a variety of
distributions from concentrated to
wide.
REFLECTOR
Computer aided designed,
reflector mounts easily and allows
multiple distribution patterns for
precise control. Special contours
and unique system of facets
minimizes arc tube voltage rise.
LENS
OPTIONS + ACCESSORIES
OPTIONS (add as suffix) 10
P=Pre-set Socket Position from the factory
SS=Space Saver Feature
QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3,
MWS, RM or HC)
RM=Remote Mount 11
HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures
outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 12
HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring
all wiring to be installed in conduit) 12, 13
HSW=Integral LumaWatt Sensor and Control with Wide Distribution for CWA Magnetic Ballast 12
Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start)
EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts)
EM/SC=Quartz Restrike wired for Separate Circuit 14
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240, or 480V only)
FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation)
PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P,
and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V
ACCESSORIES (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L3720P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1, FL-1, or SHK
PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage
PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must
be used with FL-1 and
TPPH-NEMA (Thru-Way Pendant Power Hook)
TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage
PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage.
EXAMPLE: PHC-120V
PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook).
EXAMPLE: PHC-120V-NEMA
C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK)
MW=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and
11 ft. also available. Please refer to MWS Modular Wiring System section for additional information)
SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available.
EXAMPLE: SCF6=6' Cable)
SCR=Aircraft Safety Cable for Housing to Reflector
L/TCB=Less Top Connector Box (Housing shipped less top connector box. Specify when using TWMBS
accessory)
LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped
separate from luminaire unless otherwise noted)
QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is
shipped separate from luminaire unless otherwise noted)
TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage
TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (120, 277, or 347V)
TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage (208, 240 or 480V)
TWMBS=Thru-way Mounting Box
C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK
MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs)
WG19/SGB/AV=Wire Guard with Safety Glass Bottom
Clear tempered glass lens in an
extruded aluminum hinged door
frame with latches to allow access
for relamping without tools.
S H I P P I N G D ATA
Approximate Net Weight:
38-50 lbs. (17-23 kgs.)
NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 175, 200, 250, 320, 350, 400, 450W only. 3 277V only, not available with Q, EM, HL or HC option. 4 Factory set for concentrated, medium or wide
distributions only if P (factory pre-set) is in the nomenclature of the fixture. 5 HPS only. 6 Products also available in non-US voltages and 50HZ for international markets. 7 Multi-tap ballast 120/208/240/277V wired 277V.
8 Triple-tap ballast 120/277/347V wired 347V. 9 5-tap ballast 120/208/240/277/480V wired 480V. 400W MH only. 10 Must be listed in order shown and separated by a dash. 11 Not available with QD, W, WL options.
12 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA ballast only. 13 Not available with QD PC3, C3, PHC or MWS.
Not available with single circuit MWS special order. 14 Not available with HL or HC option.
5 Indoor Lighting Solutions
Cooper Lighting
Aluminum High-Bay<<<INDUSTRIAL
175-450W
HP/MH/MP/ML/MD
EB E&G VertX
H E AV Y- D U T Y E N C L O S E D & G A S K E T E D V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E
Powered
by
technology
30"
[762mm]
A P P L I C AT I O N
The EB E&G VertX aisle lighter is ideal for
higher mounting height warehouse
applications. Its unique distribution pattern
delivers high horizontal illumination while
reducing “scallops” or hot spots for a more
uniform vertical surface.
19" [483mm]
LUMARK®
O R D E R I N G I N F O R M AT I O N
MOUNTING
S A M P L E N U M B E R : H P E B - E N A V 1 9 - M - 4 0 0 - M T- Q
Easy slide-on die-cast aluminum
mounting box with tapped opening
LAMP TYPE
SERIES
REFLECTOR TYPE
HP=High
ENAV=Enclosed
EB=E&G VertX
Pressure
& Gasketed
Sodium 1
VertX
MH=Metal Halide
2
MP=Pulse Start MH (CWA)
ML=Pulse Start MH (Linear Reactor) 2, 3
MD=Pulse Start Metal Halide (Electronic) 2, 4
REFLECTOR
DIAMETER
19=19"
SOCKET POSITION/
DISTRIBUTION 5
C=Concentrated
M=Medium
W=Wide
LAMP
WATTAGE
150=150W 6
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
450=450W
VOLTAGE 7
OPTIONS +
120V
ACCESSORIES 12
208V 8
(See Below)
240V 8
277V 8
347V
480V
MT=Multi-Tap 9
TT=Triple-Tap 10
5T=5-Tap 11
E=Electronic 8
for 3/4" conduit.
HOUSING
Durable heavy-duty die-cast
aluminum housing for lasting
performance in the harshest
environments. Integrally hinged for
ease of maintenance with optional
toolless entry. Finished in a white
OPTIONS + ACCESSORIES
OPTIONS (add as suffix) 12
PS=Protective Starter (Available in 1000W HPS only. For other wattages, consult factory)
SS=Space Saver Feature
QB=Quiet Ballast (Available on the Benchmark ballast housing only)
QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3,
MWS, RM or HC)
RM=Remote Mount 13
TE=Toolless Entry
HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures
outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 14
HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring
all wiring to be installed in conduit) 14, 15
HSW=Integral LumaWatt Sensor and with Wide Distribution Control for CWA Magnetic Ballast 14
LC=Low Voltage Control (0-10V DC Low voltage leads pulled out of top connection box for areas requiring all
wiring to be installed in conduit. Available with Benchmark housing and electronic HID ballast only—MD
lamp type) 14, 16
LSW=Integral 0-10V Sensor and with Wide Distribution Control for ECONTM Electronic Ballast 14, 16
Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start)
EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts)
EM/SC=Quartz Restrike wired for Separate Circuit 3
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240, or 480V only)
FILT=Sintered Bronze Filter (Sintered bronze filter prevents the entrance of contaminants)
FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation)
polyester powder coat.
BALLAST
PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, AND 480V-L820P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1,
or SHK. EXAMPLE: PC3-120V
PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage.
EXAMPLE: PHC-120V-NEMA
PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook).
EXAMPLE: PHC-NEMA
C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK)
MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and
11 ft. also available. Please refer to MWS Modular Wiring System section for additional information)
SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available.
EXAMPLE: SCF6=6' Cable)
SCR=Aircraft Safety Cable for Housing to Reflector
L/TCB=Less Top Connector Box (Housing shipped less top connector box. Used when using TWMBS
[Steeler Family] and TW [Benchmark Family] accessories)
LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped
separate from luminaire unless otherwise noted)
QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is
shipped separate from luminaire unless otherwise noted)
WL=Wet Location Listed Luminaires 17
High-power factor ballast with class
H insulation. Minimum starting
temperature is -40°C (-40°F) HPS
and -30°C (-20°F) for MH, MP, ML,
and MD.
SOCKET
Mogul-base porcelain socket.
NECK
Die-cast aluminum neck with
staggered mounting bosses for
eight-position adjustability of the
socket which provides a variety of
distributions from concentrated to
wide.
ACCESSORIES (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and
480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord).
Requires FH-1, FL-1, or SHK
PHC-XXXV=Power Cord and Plug—18" Power Cord and Non-NEMA plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage
PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration.
Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook)
TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage
TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage
REFLECTOR
TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC.
Specify Voltage
C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK
MBT=Twin Mount Bracket (Fixtures must be same voltage, wattage, and without hooks, loops or plugs)
TW=Thru-way Mounting Box
WG19/SGB/AV=Wire Guard with Safety Glass Bottom
Computer aided designed,
reflector mounts easily and allows
multiple distribution patterns for
precise control. Special contours
and unique system of facets
minimizes arc tube voltage rise.
LENS
Clear tempered glass lens in an
extruded aluminum hinged door
frame with latches to allow access
for relamping without tools.
NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 200, 250, 320, 350 and 450W only. 277V only, not available with Q or EM option. 3 Not available with HL or HC. 4 Electronic available in 320, 350 and 400W only.
(See ECON section for list of current approved lamps at www.cooperlighting.com). 5 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 6 HPS only.
7 Products also available in non-US voltages and 50Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering information. 8 MD available in 208, 240 or 277V or with “E”
option which will operate voltages from 200-277V 50/60 Hz. 9 Multi-tap ballast 120/208/240/277V wired 277V. 10 Triple-tap ballast 120/277/347V wired 347V. 11 5-tap ballast 120/208/240/277/480V wired 480V.
12 Must be listed in order shown and separated by a dash. 13 Not available with QD, W, WL option. 14 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations
for compatible lamps. For use with CWA or ECONTM ballast only. 15 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 16 Specify when using MD lamp type only.
17 Not available with HL, HC, HSW, LC, and LSW options.
Cooper Lighting
S H I P P I N G D ATA
Approximate Net Weight:
34-47 lbs. (15-21 kgs.)
Indoor Lighting Solutions
6
CUSTOMER FIRST CENTER
1121 HIGHWAY 74 SOUTH
PEACHTREE CITY, GEORGIA 30269
770 486 4800
FAX 770 486 4801
Domestic Facilities, USA
Cranbury, New Jersey
Elk Grove Village, Illinois
Irving, Texas
Ontario, California
Peachtree City, Georgia
International Sales, USA
Peachtree City, Georgia
CANADA
Cooper Lighting
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
905 507 4000
FAX 905 568 7049
Domestic Facilities, Canada
Calgary, Alberta
Chomedey, Laval P.Q.
The Cooper Lighting Family
Halo
Cooper Lighting - Metalux
Cooper Lighting - Lumark
Cooper Lighting - Sure-Lites
Neo-Ray
Corelite
Portfolio
Iris
Shaper
Lumière
Invue
McGraw-Edison
Fail-Safe
MWS
DLS
RSA
Ametrix
VertX
Vertical Aisle Lighter High-Bay Luminaire
Cooper Lighting, Inc.
All rights reserved
Printed in USA
www.cooperlighting.com
ADH050438