FAIL-SAFE ® DESCRIPTION The Fail-Safe VR 2000 15" Round combines strength-gaining architecture with energy-saving technology. Architecturally angled facets blend with its circular form to actually increase the ability of the lens to deflect blows and absorb impact. Extra thick injection-molded polycarbonate lens incorporates an optical design that obscures the lamp image and spreads light evenly. UL/cUL listed for wet locations. The durable, versatile 15" Round UC/UW is perfect for use in corridors, dormitories, public rest rooms, rapid transit stations, loading docks and minimum security institutions. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S Fa s te n e r s Four T20 stainless steel TORX® screws with center reject pin. Screw-heads are recessed into lens to maximize tamper-resistance. Fasteners are captive in the lens and sealed by means of a neoprene O-ring. Housing Die-cast aluminum with reinforcing ribs on exposed sidewalls. Thickened areas occur at lens junction and at mounting/fastening holes. Four 1/4" dia. fasteners are required for maximum vandal resistance. Four 1/2" NPT entries for surface conduit. S o cke t R e f l e c to r Porcelain medium base socket with nickel-plated brass screw shell. Shock absorbing socket bracket protects lamps from impact. 16 ga. CRS with white high reflectance polyester powder coat finish. Lamp G a s ke t By others. One-piece, die-cut, closed-cell EPDM mounting gaskets seal entire lens and housing. Ballast Lens One-piece, injection-molded UV stabilized polycarbonate min. 0.130" thick. All light control prisms & blondels are on the inside surface of the lens, reducing dirt build-up and making cleaning easier. Copper-wound NPF ballast standard. H-Rx ballasts are available in normal and high power factors with some lamps. Consult ordering information. H E = H o ri zo n t a l E ye l i d Labels UL/cUL listed, standard wet locations. P P = Pa i n te d Pe ri m e te r 15" dia. [381 mm] UC UW 15" Round VR2000 Metal Halide High Pressure Sodium Vandal Resistant SIDE DIMENSIONS SURFACE Polycarbonate Clear Prismatic or White Open or Eyelid Deep Casting 15" [381 mm] 3 1/2" [89 mm] 5 7/16" [138 mm] E N E R G Y D ATA For Energy Management related technical data to support the performance of this fixture series, refer to the ordering information for input wattage. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADC041453 2010-05-07 10:25:26 UC / UW O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HPUC-PP-70N-120V Lamp Type Paint Configuration Product Family HP=High Pressure 1 Sodium 1 MH=Metal Halide Wattage PP=Perimeter Paint HE=Horizontal Eyelid Voltage Ballast N=Normal Power Factor W=CWA (175 MH only) 15” Round UC=Clear Prismatic Polycarbonate Lens UW=White Polycarbonate Lens Accessories (Order separately) Color PB-120V=Photocell Kit 3 PB-277V=Photocell Kit 3 VRSD =T20 Center-pin tamperproof TORX®-head bit F1=Single Fused F2=Double Fused LL=Lamp Included Q=Quartz Restrike QS=Quartz Socket H=High Power Factor 35=35W 50=50W 70=70W 100=100W 2 150=150W 2 175=175W 2 Options 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V MT=Multi-Tap 120, 208, 240, 277V DT =Dual-Tap 120/277V NOTES: Blank=Black (Standard) WHT=White DBZ=Bronze AP=Gray 1 All units incorporate deep casting. 2 Not available with white lens. 3 Requires deep casting. O R D E R I N G M AT R I X LAMP TYPE/ WATTAGE MH BALLAST .. . . ... .. W (Metal Halide) 50=50W All Units Have 70=70W 100=100W 175=175W HPS (High Pressure Sodium) 35=35W Deep Casting 50=50W 70=70W 100=100W . 150=150W N ... . .. .. . ... . .. .. . H VOLTAGE ... . .. ... 120 277 ... . .. ... .. . .. . MT * - * = Not available = Available .. .. ... .. F1 * OPTIONS .. .. .. .. . F2 .. . .. . LL Q ... . ... .. QS = Only available in HPF Ballast P H OTO M E T R I C S Candlepower Coefficients of Utilization 90o Effective floor cavity reflectance rc rw 80% 70% 70 50 30 10 70 50 30 10 Angle 0.0 0% 0 716 0 5 723 15 776 20% 50% 30% 50 30 10 10% 50 30 10 50 30 10 RCR o 60 o 30 o 0 MHUC-PP-175H-120 (1) 175W MH/CL Med. Lamp 14000 Lumens Efficiency: 65.3% 0 75 75 75 75 72 72 72 72 67 67 67 62 62 62 57 57 57 55 25 927 1 65 60 56 52 62 57 53 50 52 49 46 48 45 43 44 42 40 38 35 1178 2 57 50 44 38 54 47 42 37 43 39 35 39 36 32 36 33 30 28 45 1235 3 51 42 35 30 48 40 34 29 36 31 27 33 29 25 30 26 23 21 55 1429 4 46 36 29 24 43 35 28 23 32 26 22 29 24 20 26 22 19 17 65 1387 5 41 32 25 19 39 30 24 19 27 22 18 25 20 16 23 19 15 13 75 1325 6 38 28 21 16 36 26 20 15 24 19 14 22 17 13 20 16 12 11 85 1138 7 34 24 18 13 32 23 17 13 21 16 12 19 15 11 17 13 10 9 90 1077 8 32 22 15 11 30 21 15 11 19 14 10 17 13 9 16 12 9 7 95 1044 9 29 19 13 9 28 19 13 9 17 12 8 16 11 8 14 10 7 6 105 266 10 27 18 12 8 26 17 11 8 15 11 7 14 10 7 13 9 6 5 115 44 Zonal Lumen Summary Spacing Criterion: 2.4 Ballast Factor: 1.0 Report # 767212 Zone 0- 30 0- 40 0- 60 0- 90 0-180 Lumens 723 1449 3692 7710 9145 %Lamp 5 10 26 55 65 %Fixture 8 16 40 84 100 Specifications and dimensions subject to change without notice. Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADC041453 2010-05-07 10:25:26