EBP700X and EBP700F SURE-LITES page 1 Installation Instructions for EBP700X and EBP700F IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. 2. Do not use outdoors. 3. Do not mount near gas or electric heaters. 4. Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by unauthorized personnel. 5. The use of accessory equipment not recommended by Sure-Lites may cause an unsafe condition. 6. Do not use this equipment for other than its intended purpose. 7. Risk of Fire/Electric Shock If not qualified, consult an electrician. SAVE THESE INSTRUCTIONS Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing. Note 1. To prevent high voltage from being present on the output terminals (red/white, red, and yellow), do not connect the test button indicator light to the EBP until Step 7 of the installation instructions. Note 2. This product is for use with most 2’ through 8’ (13W-215W single and bipin fluorescent lamps including energy saving, circline, U-shaped and biax. For specific lamp compatibility, please see the table later in the instructions. Note 3. Make sure all of the connections are in accordance with the National Electrical Code and any local regulations. Note 4. To reduce the risk of electrical shock, disconnect both normal and emergency power supplies and the test button indicator light (which disconnects the battery) before servicing. Note 5. This emergency ballast is for factory or field installation in the ballast channel. Note 6. This product is for use in indoor fixtures. This product is not intended for use near air handling heated air outlets or in wet or hazardous locations. Note 7. An unswitched AC power source is required (120, 240, or 277 volts). Note 8. Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field replaceable. Contact the manufacturer for information on service. Note 9. Servicing should be performed by qualified service personnel. For use in temperature rating 20°C to 55°C CONTAINS NICKEL-CADMIUM RECHARGEABLE BATTERY. MUST BE RECYCLED OR DISPOSED OF PROPERLY. Ni - Cd EBP700X EBP700F Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/12/11 024-116 EBP700X and EBP700F SURE-LITES page 2 INSTALLATION WARNING: TO PREVENT HIGH VOLTAGE ON RED / WHITE, RED, AND YELLOW OUTPUT TERMINALS PRIOR TO INSTALLATION, THE TEST BUTTON / INDICATOR LIGHT MUST BE DISCONNECTED. CONNECT THE TEST BUTTON / INDICATOR LIGHT AFTER INTSALLATION. Note: Make sure that the necessary branch circuit wiring is available. An unswitched source of power is required. Step 1. Disconnect AC power from the fixture. Remove the ballast channel cover and install the emergency ballast either in the ballast channel (see illustrations 1 & 2) or on top of the fixture (see illustration 3 / EBP700X only). ILLUSTRATION 1 ILLUSTRATION 2 Emergency Ballast ILLUSTRATION 3 Emergency Ballast Wire Bundle Cover Emergency Ballast Test Button/ Indicator Light Drill 1/8˝ Hole for Mounting Screws Test Button/ Indicator Light Wire Bundle Cover Ballast Channel Cover 1/2˝ Std. Knockout 7/8˝ Hole w/Bushing EBP700X only Step 2. Select the appropriate wiring diagram to connect the emergency ballast to the AC ballast and lamp. Make sure all connections are in accordance with the National Electrical Code and any local regulations. (See Illustrations 4 and 5 for terminals). 1121 Highway Peachtree City Emergenc Suitable fo RED / WH RED BLUE BLUE / WH YELLOW AUX N.O. AUX COMMON Color coded label located here. YELLOW / BK AUX COM AUX N.C. LINE HOT 120/240/277 AUX N.C. LINE NEUTRAL AUX N.O. LINE HOT 120/240/277 LINE NEUTRAL Terminal labels located here. ILLUSTRATION 5 TEST BU LIGHT C ILLUSTRATION 4 Test Button / Indicator Light Connector Step 3. Refer to proper lamp compatibility table for the HIGH (Red) or Low (Red / White) connection per the lamp being illuminated by the emergency ballast. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/12/11 024-116 EBP700X and EBP700F SURE-LITES page 3 Lamp Compatibility Tables Lamp Type Number of Lamps Lamps Connected to Low/High (Red) Output Wattage T5 T5 T5HO T5,T9 CIRC T8 T8 T8HO T8U T12 T12 T12HO T12VHO BIAX BIAX T5 T5 T5HO T8 T8HO T8U T12 T12HO BIAX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 HIGH (RED) LOW (RED / WHITE) LOW (RED / WHITE) LOW (RED / WHITE) HIGH (RED) LOW (RED / WHITE) LOW (RED / WHITE) HIGH (RED) HIGH (RED) LOW (RED / WHITE) LOW (RED / WHITE) LOW (RED / WHITE) HIGH (RED) LOW (RED / WHITE) HIGH (RED) LOW (RED / WHITE) LOW (RED / WHITE) HIGH (RED) LOW (RED / WHITE) LOW (RED / WHITE) LOW (RED / WHITE) LOW (RED / WHITE) HIGH (RED) 13-21 28-35 24-54 22-55 15-32 36-59 48-86 16-32 20-40 56-75 25-110 95-215 18-40 55 6 13-28 24-54 15-32 48 16-32 20-40 25-95 18 ILLUSTRATION 6 ILLUSTRATION 7 TROFFER STYLE FIXTURE STRIP STYLE FIXTURE Fixture Emergency Ballast Ballast Channel Cover Leads to Test Button/ Indicator Light 7/8" Punch Test Button/ Indicator Light 7/8" Bushing Inserted into Ballast Channel Cover Plastic Tubing (cut to necessary length) Test Button/Indicator Light Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 Nut 4/12/11 024-116 EBP700X and EBP700F SURE-LITES page 4 Step 4. Install the test button / indicator light through the ballast channel cover of a troffer (Illustration 1 & 6) or through the side of a strip fixture (Illustration 2 & 7). Drill or punch a7/8” hole to install the test button / indicator light as shown in illustration 6. Drill or punch a 1/2” hole to install the test button / indicator light as shown in illustration 7. Install the test button / indicator light as shown in the selected illustration. Apply the two included labels (“Charging Indicator Light” and “Emergency Light Push to Test”) adjacent to the test button indicator light. Step 5. In a readily visible location, attach the included label “CAUTION – This unit Has More Than One Power Connection Point. To Reduce The Risk Of Electric Shock, Disconnect Both The Branch Circuit-Breakers Or Fuses and the Test Button / Indicator Light Before Servicing”. Step 6. In an area readily visible during relamping, attach the included relamping label. Write in the lamp type and wattage. Step 7. After installation is complete, connect the test button / indicator light, and supply AC power to the emergency ballast, and replace covers while being careful not to pinch wires. Step 8. A short term discharge test may be conducted after the emergency ballast has been charging for one hour. Charge for 24 hours before conducting a long – term discharge test. Refer to OPERATION. OPERATION: When AC power is applied, the charging indicator light is illuminated, indicating the battery is being charged. When power fails, the emergency ballast automatically switches to emergency power, operating one or two lamps at reduced illumination for at least 90 minutes. MAINTENANCE: Although no routine maintenance is required to keep the emergency ballast functional, it should be checked periodically to comply with local codes. The following schedule is recommended: Step 1. Visually inspect the charging light monthly. It should be illuminated Step 2. Test the emergency operation of the fixture at 30 day intervals for a minimum of 30 seconds. Depending on installation, one or two lamps should operate at reduced illumination. Step 3. Conduct a 90 – minute discharge test once a year. Depending on installation, one or two lamps should operate at reduced illumination for at least 90 minutes. Refer any service requirements indicated by these checks to qualified personnel. Note: After installing the test button / indicator light, mark it with the appropriate label. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/12/11 024-116 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 AC BALLAST LAMP ("EMERGENCY") RED RED BLUE BLUE YELLOW BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST YELLOW/BK LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT YELLOW YELLOW LINE NEUTRAL AC BALLAST 4/12/11 024-116 YELLOW YELLOW LINE NEUTRAL AC BALLAST RED RED BLUE BLUE LAMP-2 ("EMERGENCY") LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LAMP-2 ("EMERGENCY") LINE NEUTRAL LINE HOT AUX NC AUX NO LINE HOT LAMP ("EMERGENCY") BLUE RED OR RED/WH CHOOSE BASED ON LAMP BLUE LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST YELLOW/BK YELLOW BLUE/WH BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW YELLOW/BK LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST 2 LAMP RAPID START SERIES LAMP SERIES YELLOW FILAMENT AC BALLAST LAMP-1 BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP AUX COM RED LINE NEUTRAL LINE HOT 1 LAMP INSTANT START LAMP-1 RED RED BLUE BLUE YELLOW YELLOW/BK EMERGENCY BALLAST 2 LAMP RAPID START SERIES / PARALLEL LAMP PARALLEL YELLOW FILAMENT LINE HOT LINE NEUTRAL LINE HOT 1 LAMP RAPID START LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT SURE-LITES EBP700X and EBP700F page 5 TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 YELLOW YELLOW BLUE BLUE LINE NEUTRAL LINE HOT YELLOW YELLOW LINE NEUTRAL LINE HOT LAMP-2 ("EMERGENCY") LAMP-1 RED RED BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM AC BALLAST 4/12/11 024-116 LAMP-3 LAMP-2 ("EMERGENCY") LAMP-1 RED RED BLUE/WHT BLUE/WHT BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW YELLOW/BK LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST 3 LAMP RAPID START SERIES LAMP PARALLEL YELLOW FILAMENT AC BALLAST BLUE BLUE YELLOW/BK EMERGENCY BALLAST LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 2 LAMP RAPID START OSRAM SYLVANIA SERIES LAMP PARALLEL YELLOW FILAMENT LINE NEUTRAL LINE HOT LINE NEUTRAL LINE HOT AC BALLAST AC BALLAST RED OR RED/WH CHOOSE BASED ON LAMP BLUE BLUE/WH LAMP-3 ("EMERGENCY") LAMP-2 LAMP-1 RED OR YELLOW BLUE BLUE BLUE YELLOW/BK BLUE/WH YELLOW RED OR RED/WH CHOOSE BASED ON LAMP BLUE LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST 3 LAMP INSTANT START LAMP-2 ("EMERGENCY") LAMP-1 RED BLUE BLUE YELLOW YELLOW/BK EMERGENCY BALLAST 2 LAMP INSTANT START LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LINE NEUTRAL (UNSWITCHED) 120/240/2277 SWITCHED OR UNSWITCHED LINE HOT SURE-LITES EBP700X and EBP700F page 6 TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 YELLOW YELLOW LINE HOT LINE NEUTRAL YELLOW YELLOW BROWN BROWN LINE HOT LINE NEUTRAL LAMP-4 ("EMERGENCY") LAMP-3 LAMP-2 LAMP-1 RED RED BLUE/WHT BLUE/WHT EMERGENCY BALLAST BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 4/12/11 024-116 RED RED BLUE BLUE LAMP-3 ("EMERGENCY") LAMP-2 LAMP-1 AC BALLAST RED/WHT RED/WHT EMERGENCY BALLAST BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW/BK YELLOW LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 3 LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT AC BALLAST BLUE BLUE YELLOW/BK YELLOW 4 LAMP RAPID START SERIES LAMP PARALLEL YELLOW FILAMENT YELLOW YELLOW LINE NEUTRAL LINE HOT YELLOW YELLOW LINE NEUTRAL LINE HOT LAMP-4 ("EMERGENCY") LAMP-3 LAMP-2 LAMP-1 RED RED BLUE BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW BLUE/WH BLUE LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LAMP-4 ("EMERGENCY") LAMP-3 LAMP-2 LAMP-1 AC BALLAST BLUE/WHT BLUE/WHT RED/WHT RED/WHT BLUE BLUE RED RED EMERGENCY BALLAST BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW/BK YELLOW LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 4 LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT AC BALLAST YELLOW/BK EMERGENCY BALLAST 4 LAMP INSTANT START SURE-LITES EBP700X and EBP700F page 7 TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION EBP700X and EBP700F SURE-LITES page 8 WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS BI LEVEL BALLAST SWITCHED LINE HOT EMERGENCY BALLAST YELLOW/BK SWITCHED LINE HOT LINE NEUTRAL YELLOW BLUE/WH WIRE LAMPS USING DIAGRAM PER # OF LAMPS AND BALLAST TYPE BI-LEVEL AC BALLAST BLUE RED OR RED/WH CHOOSE BASED ON LAMP AUX COM AUX NO LINE NEUTRAL AUX NC LINE HOT (UNSWITCHED) 120/240/277 LINE NEUTRAL When using the auxillary relay to switch the neutral line, the Emergency and A.C. ballasts must be on the same branch circuit. WIRING DIAGRAMS FOR 2-LAMP EMERGENCY OPERATION LINE NEUTRAL (UNSWITCHED) 120/240/277 LINE HOT LINE NEUTRAL 024-116 LAMP-2 ("EMERGENCY") RED RED YELLOW YELLOW AC BALLAST LINE NEUTRAL 4/12/11 LAMP-1 ("EMERGENCY") RED OR RED/WH CHOOSE BASED ON LAMP AUX NC AUX NO AUX COM BLUE/WH BLUE BLUE BLUE YELLOW/BK YELLOW EMERGENCY BALLAST SWITCHED OR UNSWITCHED LINE HOT Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 LINE HOT LAMP-2 ("EMERGENCY") LAMP-1 ("EMERGENCY") RED RED YELLOW YELLOW 2 LAMP RAPID START SERIES LAMP SERIES YELLOW FILAMENT (UNSWITCHED) 120/240/277 LINE HOT RED OR RED/WH CHOOSE BASED ON LAMP LINE NEUTRAL LINE NEUTRAL SWITCHED OR UNSWITCHED LINE HOT AUX NC AUX NO BLUE/WH BLUE AUX COM BLUE BLUE AC BALLAST LINE NEUTRAL EMERGENCY BALLAST YELLOW/BK YELLOW LINE HOT 2 LAMP RAPID START SERIES / PARALLEL LAMP PARALLEL YELLOW FILAMENT FOR OPTIMUM LAMP LIFE, COOPER LIGHTING RECOMMENDS WIRING FOR SINGLE LAMP EMERGENCY OPERATION. WHILE CAPABLE OF 2 LAMP EMERGENCY OPERATION, NOT ALL AC BALLASTS ARE COMPATIBLE WITH 2 LAMP EMERGENCY OPERATION. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 LAMP-2 ("EMERGENCY") LAMP-1 ("EMERGENCY") BLUE BLUE RED RED RED OR RED/WH CHOOSE BASED ON LAMP BLUE/WH BLUE LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST YELLOW/BK YELLOW 4/12/11 024-116 LAMP-3 LAMP-2 ("EMERGENCY") LAMP-1 ("EMERGENCY") RED YELLOW BLUE/WHT BLUE/WHT RED AC BALLAST RED OR RED/WH CHOOSE BASED ON LAMP BLUE/WH BLUE YELLOW/BK YELLOW LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL EMERGENCY BALLAST 3 LAMP RAPID START SERIES LAMP PARALLEL YELLOW FILAMENT AC BALLAST YELLOW BLUE BLUE LINE NEUTRAL LINE HOT YELLOW YELLOW LINE NEUTRAL LINE HOT LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 2 LAMP RAPID START OSRAM SYLVANIA SERIES LAMP PARALLEL YELLOW FILAMENT LINE NEUTRAL LINE HOT LINE NEUTRAL LINE HOT AC BALLAST AC BALLAST RED OR RED/WH CHOOSE BASED ON LAMP BLUE BLUE/WH YELLOW LAMP-3 ("EMERGENCY") LAMP-2 ("EMERGENCY") LAMP-1 RED OR YELLOW BLUE BLUE BLUE RED OR RED/WH CHOOSE BASED ON LAMP BLUE/WH BLUE YELLOW/BK YELLOW LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST LINE NEUTRAL LINE HOT AUX NC AUX NO EMERGENCY BALLAST AUX COM 3 LAMP INSTANT START LAMP-2 (EMERGENCY) LAMP-1 (EMERGENCY) RED BLUE BLUE YELLOW/BK 2 LAMP INSTANT START LINE NEUTRAL UNSWITCHED 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LINE NEUTRAL UNSWITCHED 120/240/277 SWITCHED OR UNSWITCHED LINE HOT SURE-LITES EBP700X and EBP700F page 9 WIRING DIAGRAMS FOR 2-LAMP EMERGENCY OPERATION FOR OPTIMUM LAMP LIFE, COOPER LIGHTING RECOMMENDS WIRING FOR SINGLE LAMP EMERGENCY OPERATION. WHILE CAPABLE OF 2 LAMP EMERGENCY OPERATION, NOT ALL AC BALLASTS ARE COMPATIBLE WITH 2 LAMP EMERGENCY OPERATION. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS LINE HOT Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 YELLOW YELLOW LINE NEUTRAL YELLOW YELLOW LINE NEUTRAL BROWN BROWN LINE HOT RED RED BLUE/WHT BLUE/WHT RED OR RED/WH CHOOSE BASED ON LAMP BLUE BLUE/WH LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 4/12/11 024-116 RED RED BLUE BLUE LAMP-3 ("EMERGENCY") LAMP-2 ("EMERGENCY") LAMP-1 AC BALLAST RED/WHT RED/WHT EMERGENCY BALLAST RED OR RED/WH CHOOSE BASED ON LAMP BLUE/WH BLUE YELLOW/BK YELLOW LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 3 LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT LAMP-4 ("EMERGENCY") LAMP-3 ("EMERGENCY") LAMP-2 LAMP-1 AC BALLAST BLUE BLUE YELLOW/BK YELLOW 4 LAMP RAPID START SERIES LAMP PARALLEL YELLOW FILAMENT YELLOW YELLOW LINE NEUTRAL LINE HOT YELLOW YELLOW LINE NEUTRAL LINE HOT LAMP-2 LAMP-1 RED RED BLUE BLUE RED OR RED/WH CHOOSE BASED ON LAMP BLUE BLUE/WH LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM EMERGENCY BALLAST LINE NEUTRAL UNSWITCHED 120/240/277 SWITCHED OR UNSWITCHED LINE HOT LAMP-4 ("EMERGENCY") LAMP-3 ("EMERGENCY") LAMP-2 LAMP-1 AC BALLAST BLUE/WHT BLUE/WHT RED/WHT RED/WHT BLUE BLUE RED RED EMERGENCY BALLAST BLUE/WH BLUE RED OR RED/WH CHOOSE BASED ON LAMP YELLOW YELLOW/BK LINE NEUTRAL LINE HOT AUX NC AUX NO AUX COM LINE NEUTRAL (UNSWITCHED) 120/240/277 SWITCHED OR UNSWITCHED LINE HOT 4 LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT LAMP-4 ("EMERGENCY") LAMP-3 ("EMERGENCY") AC BALLAST YELLOW/BK YELLOW 4 LAMP INSTANT START SURE-LITES EBP700X and EBP700F page 10 WIRING DIAGRAMS FOR 2-LAMP EMERGENCY OPERATION FOR OPTIMUM LAMP LIFE, COOPER LIGHTING RECOMMENDS WIRING FOR SINGLE LAMP EMERGENCY OPERATION. WHILE CAPABLE OF 2 LAMP EMERGENCY OPERATION, NOT ALL AC BALLASTS ARE COMPATIBLE WITH 2 LAMP EMERGENCY OPERATION. TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER BALLAST. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS