Technical Data TD032098EN Effective April 2015 915U-DNP3 outstation DNP3 protocol feature key for 115E-2 industrial applications Applications Certificate Thank you for purchasing the ELPRO 915U-2 Feature Code. • • Water and wastewater systems SCADA Specifications Date: 26/02/2015 Module Serial Number: Modbus Feature Code: Logging Feature Code: 915U-2 Feature Code Certificate The 915U-2 provides functionality that can be enabled by providing a code that is specific to the unit and to the feature being enabled (The Feature Code). This certificate provides a record of the feature codes that have been purchased for the 915U-2 with the serial number listed above. If these codes were purchased at the time of ordering the module, these features may have already been enabled in the module. In this case the Feature Code will be documented on the module test report. If the codes were purchased subsequent to purchasing the module, refer to the user manual for instructions on how to enable the additional features. Retain this certificate, as it may be necessary to re-enter the feature codes for this device at some stage in the future. SPECIFICATION Connectivity DNP3 TCP DNP3 UDP Data Types Analog inputs Analog outputs www.eaton.com/wireless Description The ELPRO 915U-DNP3 feature key provides DNP3 outstation protocol support for the 115E-2 product family. DNP3 protocol support can be combined with Modbus® RTU/TCP to provide a powerful gateway to interface DNP3 to many other Modbus‑based devices. I/O expansion through the use of ELPRO 115S expansion modules are also fully and seamlessly supported by the 915U-DNP3. Features • • • • • DNP3 TCP/UDP (Ethernet) Level 2 outstation support Modbus gateway Remote configuration Automatic time synchronization Binary input Binary output Counter Protocol Level Unsolicited event reporting Static data Event data Alarms Time synchronization Remote configuration Configuration Configuration utility Web page configuration Remote configuration DESCRIPTION Supported on Ethernet port Supported on Ethernet port Time stamped events with dead-band and scaling to engineering units Select-operate functionality with scaling from engineering units Time stamped events Select-operate functionality with single bit outputs Time stamped events with dead-band and counter freeze operation Level 2 outstation slave device Can be enabled or disabled by event class Immediate I/O status Time stamped I/O events Send alarm state with time stamped support Synchronize internal real time clock with DNP3 master or NTP server DNP3 master can make configuration changes to polling class and dead bands PC based configuration program for all DNP3 parameters via USB or Ethernet ports Via internal Web page Using PC configuration utility or via internal Web page Technical Data TD032098EN 915U-DNP3 outstation Effective April 2015 Ordering PRODUCT CODE 915U-DNP3 DESCRIPTION DNP3 protocol support feature key Accessories PRODUCT CODE DESCRIPTION I/O Devices 115E-2 DATA SHEET Ethernet networking I/O and gateway TD032097EN Eaton’s wireless business www.eaton.com/wireless North America & Latin America 5735 W. Las Positas Suite 100 Pleasanton, CA 94588 United States Telephone: +1 925 924 8500 Australia, New Zealand 9/12 Billabong Street Stafford Queensland 4053 Australia Telephone: +61 7 3352 8600 Southeast Asia 2 Serangoon North Avenue 5 # 06-01 Fu Yu Building, 554911 Singapore Telephone: +65 6645 9888 Europe Hein-Moeller-Straße 7-11 53115 Bonn, Germany Telephone: +49 (0) 180 5223822 China 955 Shengli Road East Area of Zhangjiang High-Tech Park Shanghai, 201201 China Telephone: +86 21 2899 3600 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD032098EN April 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners.