Save time and money with remote meter reading The RFN-430SL is your

RFN-430SL Radio Frequency
Electric Meter Node
Save time and money with
remote meter reading
The RFN-430SL is your
gateway to the Smart
Grid with low-cost
remote meter reading of
medium to large
commercial and
industrial (C&I) power
customers and
advanced data
collection capabilities.
The RFN-430SL is based on the
Itron Sentinel® meter and allows
bidirectional communications of
data via Eaton’s Cooper Power
Systems Radio Frequency AMI
Network saving valuable time
and money.
The Radio Frequency AMI
Network utilizes an industry
leading self-forming,
self-optimizing, self-healing and
future-proof radio frequency
network infrastructure. There is
no field network configuration
required at any time. Once the
meter is powered up, the
network does the rest.
Reliable Communications:
Easy to use
Every RFN-430SL includes the
standard functions of:
• Remote kWh meter reading
•
Highly secure authentication,
key generation and encryption
•
Operates in the 902–928 MHz
license-free band
•
Automatic network acquisition
•
Automatic time synchronization
•
Non-volatile data storage
•
Load profile
•
Time-of-use
•
Freeze register capability
System control is through
Eaton’s Cooper Power Systems
Yukon™ Advanced Energy
Services master station, which
supports our Radio Frequency
AMI Network.
Polyphase Capabilities:
•
Underglass polyphase metering
endpoint
•
Robust data set including
provisions for load profile,
power quantities and Time-ofUse (TOU)
•
Low cost data collection
•
Provides a data gateway for
polyphase meters
•
Allows advanced billing for
polyphase customers
Remote accessability
•
On-demand readings for
information at any time
•
Smarter information,
operations and customer
service
•
Increased safety, security and
reliability
Remote metering for
medium to large power
customers just got
easier.
RFN-430SL Features:
•
•
•
•
•
•
•
Retrieves kW demand and peak
kW and stores it in the meter
Remotely reset peaks
Uses two-way radio frequency
communications
Group addressing
Electronic LCD register
Retrieves per-phase voltage and
current
Retrieves data from ANSI
C12.19 tables
Load Profile
• Data is recorded at 5-, 15-,
30- or 60-minute intervals
• Interval is controlled by the
configuration in the meter
Time-of-Use
Up to four rates and four TOU
schedules can be remotely
retrieved
• Configurable time zone with
daylight saving time and
holiday dates
Communication
•
•
Allows on-demand reads
•
The Radio Frequency AMI
Network supports Distribution
Automation (DA) and Demand
Response (DR) simultaneously
with metering activities
Specifications
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2014 Eaton
All Rights Reserved
Printed in USA
Publication No. B1110-14050
March 2014
•
Reset Power Fail Counter
•
Demand Reset
Demand Reset
The Demand Reset command
can be used with unique meter
addressing or can be broadcast
using group addressing.
Collection Capabilities
Network
A self-forming, self-configuring, self-healing wireless mesh network
Full peer-to-peer communication
Multiple, redundant paths
No network address management required
Automatic network acquisition
Automatic traffic management
Two-way authentication, one-time session keys and
128-bit AES encryption
Automatic time synchronization
Single network for electric, water and gas
Interface
Itron Sentinel® utilizing interface cable
Under-the-glass
Application
Supports all Sentinel® available socket
Compatibility
forms
Data storage
128K, stores 1 month of data
Non-volatile data storage provides extra
Data integrity
security in the event of communication or
power outage
Radio
Operating frequency
902–928 MHz
Reliable data transmission
Error detection, correction and retransmission
RF output power (max)
30 dBm
Compliance
ANSI
C12.1, C12.10, C12.18, C12.19, C12.20
FCC
Part 15
Dimensions
6.95 in. H x 6.95 in. W x 7.30 in. D
Dimensions
(17.65 cm H x 17.65 cm W x 18.54 cm D)
Operating Requirements
Power source
120-480V AC from meter
Humidity range
5–95% non-condensing
Temperature range
-40˚F to +185˚F (-40˚C to +85˚C)
Eaton’s Cooper Power Systems Business
2300 Badger Drive
Waukesha, WI 53188
United States
CooperPower.com
Addressing Options
• Unique Addressing
• Group Addressing – supports
more than 8,000 group
addresses for use with the
following commands
• Time Sync
Eaton, Cooper Power Systems and Yukon are
valuable trademarks of Eaton in the U.S. and
other countries. You are not permitted to use
the Eaton Trademarks without the prior written
consent of Eaton.
Sentinel is a registered trademark of Itron.
All other trademarks are property
of their respective owners.
Previous Interval Demand
Peak Demand(s)

Date and Time of Peak

kWh

kVARh/kVAR (optional)

Voltage per phase

Amps Per Phase

Time-of-Use (TOU)

kVAh/kVA (optional)

Remote Demand Reset

Outage Counter
Frozen Data/Self Read
Interface


6 months of
data
RS-232
For Eaton's Cooper Power Systems
RFN-430SL product information,
call 1-877-277-4636 or visit:
www.CooperPower.com