Surge Protection Made Simple ™

advertisement
Surge Protection Made Simple™
Hazardous Voltage
Will cause severe injury or death.
Working on or near energized circuits poses a
serious risk of electrical shock. De-energize all
circuits before installing or servicing this equipment
and follow all prescribed safety procedures.
DATA SIGNAL APPLICATIONS
Technical Data
Catalog number
Nominal voltage (UN)
Nominal current at 80°C (IL)
Operating temperature range
Degree of protection
Agency information
VPL line-line at 1kV/μs C3 (Up)
VPL line-line for In C2 (Up)
Wire Connections
BSPD0180DINL
0-180V
<
_100mA
-40°C to +80°C
IP20
UL
See VPL graph, line C3
See VPL graph, line C2
For optimum protection,
see wiring practices
note below.
Size 0
blade
driver
2'
Torque 3.5 Lb-In
(0.4 N•m) max.
2
1
Protected
side
1
'
4'
3'
4
3
2
Installation Instructions
Use max.
14AWG
(2.5mm2)
conductor
Mounting
Use min. 10AWG
(6mm2) conductor
NOTE: When wiring the DIN-Rail base, observe the terminal assignemnt
of the surge arrestor module according to the circuit diagram.
A
Wiring Practices
B
clic
2
1
k
3
A
Use min. 10AWG
(6mm2) Conductor
Module Removal
Circuit Diagram
Module / Base “Make-Before-Break” Schematic
For optimum protection please observe the following good wiring practices:
• Avoid routing signal wires parallel to power wiring or cables.
• Cross power and other cables at a right angle to minimize inductance or
capacitance coupling.
• Keep length of protected signal wires as short as possible.
• Use shielded wires whenever possible.
• Connect wire shields to equipotentional bonding/ground on both sides of the
SPD and protected equipment.
Wire Routing
Protected
side
1
1‘
Protected
side
U>UN
2
2‘
i
9
3
3‘
i
4
Protected
i
U>UN
1 23 4
Protected side
OK
4´ 3´2´1´
Unprotected side
Warranty
See document 3A1502 at
www.cooperbussmann.com/surge
for details of limited warranty.
4‘
i
3A1981RevA © 2012 Cooper Bussmann St. Louis, MO 63178
Publication-No. DS1697/CB; ID-No. 066950
www.cooperbussmann.com
UL Requirements
Safety Instructions
1. This Surge Protective Device (SPD) is intended for ordinary indoor use on communication loop circuits that are isolated from the Public Switched Telephone Network.
2. The SPD module shall be secured to the compatible base before applying power to the communication loop.
3. The base shall be secured to a compatible DIN-Rail ground bar using the methods described in this instruction.
4. Proper grounding continuity shall be determined.
5. Please install the protector module inaccordance with the applicable requirements of the National Electrical Code®,
Article 800 or other applicable local codes.
6. Screw terminal ratings with the applicable wire gauge sizes shall be noted.
7. The maximum circuit current for UL 497 B application is limited to 100mA.
This Surge Protective Device (SPD)
for coaxial connection may only be
installed by qualified electrical
personnel. All applicable national
and local electrical standards and
safety regulations must be
observed. The SPD must be
checked for external damage prior
to installation. If any damage or
other defects are detected, do not
install the device.
Tabulation Strike voltage in accordance with UL 497
(Protectors for Data Communication and Fire Alarm Circuits)
Strike Voltage 100V / sec
Strike Voltage 100V / μsec
Line-to-Ground
Line-to-Line
Line-to-Ground
Line-to-Line
182Vmin. 278Vmax. 182Vmin. 240Vmax. 182Vmin. 550Vmax. 6Vmin. 25Vmax.
Catalog Number
BSPD0180DINL
The installation and application of
this SPD is only permitted within the
limits shown and stated in these
installation instructions. The SPD
and the equipment connected to it
can be destroyed by loads
exceeding the stated values.
Opening, modifying or otherwise
tampering with the SPD invalidates
the warranty.
Application and Mode of Operation
The BSPD0180DINL surge protective device automatically adjusts to the operating voltage (from 0 to 180
volts) of the protected device.
When an overvoltage event occurs, the SPD voltage protection level adjusts itself based upon the output
terminal operating voltage of the base (see Diagram 1 and Oscillogram 1).
Diagram 1: Voltage protection level Up (V) (line - line)
Up (V)
UN (V)
max. [V]
200 V
Oscillogram 1
U
At IN = 5kA (8/20) μs
Category C2
175 V
At 1kV/ μs
Category C3
150 V
UN
UN Operating Voltage
USignal
125 V
UN
100 V
75 V
Operating Voltage:
UN = (0 ... 180V)
fUN ≤ 400Hz
IL ≤ 100mA
Signal Voltage:
USignal ± 5V
fgSignal = 25MHz
50 V
25 V
Limit short-circuit currents to 100mA in the vicinity of the installation.
UN
0V
20 V
40 V
60 V
80 V
100 V 120 V
140 V 160 V 180 V
UN (Operating Voltage)
3A1981RevA © 2012 Cooper Bussmann St. Louis, MO 63178
Publication-No. DS1697/CB; ID-No. 066950
www.cooperbussmann.com
Download