Portable Power Solutions for Plant Turnarounds Engineering Safety &

advertisement
Engineering
Safety &
Productivity
Portable Power Solutions
for Plant Turnarounds
Portable Power Solutions for Plant Turnarounds
Equipment Readiness Days Before Shutdown
• Eliminate the risk of unsafe portable power equipment
• No issues with limited power supplies
Current Situation
• No rush to install distribution centers and lighting
during shutdown
• No worries of equipment not working
Improve safe control of power during turnarounds with
equipment that is on-site, operational and ready-for-use.
Cooper Crouse-Hinds
Solution
Install
Equipment
Install
Equipment
(Power On)
Perform
Maintenance
Perform
Maintenance
Remove
Equipment
Remove
Equipment
(Power On)
• No worries of contractor equipment not mating with outlets
Power Off
Cooper Crouse-Hinds’
Industrial and Hazardous
Portable Power Platform
utilizes our industryleading portfolio of
NEC and IEC plugs and
receptacles to provide
custom solutions that
improve the safety,
time and control of
power distribution for
turnarounds.
Improve safety, time and control of
power distribution for turnarounds with
Cooper Crouse-Hinds as your partner
Maximize safe power readiness.
Current Situation
• Risk of unsafe equipment installed or used in classified
areas.
Portable Lighting
Portable Power Carts
Cable Assemblies and GFCI Devices
Cooper Crouse-Hinds market-leading luminaires are
available in carts or stands, allowing for the set-up of
your temporary lighting system within the hazardous
area before shutdown.
Engineered and manufactured for NEC and IEC applications in
hazardous or ordinary locations. Power carts are custom-built to
each customer’s unique application and are available with a huge
number of design features, including overload protection, forklift tubes,
environmental protection, lifting eyes, locking wheels, lockout/tagout,
and more.
Safe and reliable cable assemblies in a large variety of devices, sizes,
amperages, and lengths. Available with our industry-leading NEC
product brands including Arktite®, Ark•Gard®, Posi-Lok®, and CamLok®, as well as IEC configurations such as IEC 309 and Ex-Link®.
• Wasted time spent during shutdown moving and
connecting portable power equipment.
• Risk that equipment will not work or mate properly
at start of maintenance (cannot be validated until
shutdown occurs).
• Wasted time spent unplugging and removing equipment
before power is restored.
The Cooper Crouse-Hinds Solution
• Install and validate products before power shutdown,
allowing maintenance to begin immediately after power
is turned off.
• Issue safe and reliable cable assemblies to contractors
upon arrival, eliminating lost productivity due to product
mating errors and control power consumption in
classified areas.
• Safely restore plant operations before removing portable
equipment.
2
3
Portable Power Solutions for Plant Turnarounds
2-Wheel
Power Carts
4-Wheel & Skid
A
B
Solutions designed for industrial
and hazardous application
A Lifting Eyes
C Durable & Robust Carbon
Steel Frame
C
E
Design Features
C
A Removable Roof
B Lifting Eyes
D Forklift Confinement Tubes
E Enclosed Design Protects
Components
F Enclosed Design Protects
Components
E
C Durable & Robust Carbon
Steel Frame
E
E Forklift Confinement Tubes
D
D
F Caster, Pneumatic, SemiPneumatic, or Solid Rubber
Wheel Options
F
D
Technical Specs
Technical Specs
Hazardous
Industrial Non-Hazardous
Specifications
Hazardous
Specifications
Primary Voltage: 240 – 600V
Max Primary Current: 100A
Max Secondary Voltage: 240V
Max Secondary Current: 225A
Max Secondary Current w/ Main: 100A
Compatible Components
Transformers
7.5 kVA
9 kVA
10 kVA
15 kVA
25 kVA
Panelboards
EJB 12 circuit
Primary Voltage: 240 – 600V
Max Primary Current: 100A
Max Secondary Voltage: 480V
Disconnects
EIB
Non-Hazardous
Receptacles
CPSAR
ENR WSQC
CES WLRS FSQCWLRD
Water tight
Twist lock
Industrial Non-Hazardous
Specifications
Max Secondary Current: 225A
Max Secondary Current w/ Main: 225A
Compatible Components
Cart/Skid Sizes
Specifications
Primary Voltage: 240 – 600V
Max Primary Current: 100A
Max Secondary Voltage: 480V
Max Secondary Current: 225A
Max Secondary Current w/ Main: 100A
Compatible Components
Transformers
7.5 kVA
9 kVA
10 kVA
15 kVA
25 kVA
Panelboards
18 circuit
30 circuit
Disconnects
30A, 60A, 100A
Receptacles
CPS
ENR
CES
FSQC
CESD
Cart 1
Width: 28”
Length: 14”
Height: 58”
Primary Voltage: 240 – 600V
Max Primary Current: 200A
Max Secondary Voltage: 480V
Max Secondary Current: 225A
Max Secondary Current w/ Main: 225A
Compatible Components
Transformers
30 kVA
45 kVA
Disconnects
EIB
Panelboards
EPLBN 24 circuit
EXDBN 24 circuit
Receptacles
CPSAR
ENRWSQC
CESWLRS
FSQC
WLRD
Transformers
25 kVA 45 kVA
30 kVA 75 kVA
Disconnects
30A, 60A, 100A, 200A
Panelboards
18 circuit
30 circuit
42 circuit
Cart/Skid Sizes
Hazardous
Hazardous
Non-Hazardous
4
B
D Pneumatic, SemiPneumatic, or Solid Rubber
Wheel Options
F
• UL/cUL 1640 compliant
• 2-wheel, 4-wheel and skid options
• Standardized cart sizes reduce lead times and
eliminate potential on-site placement issues
• Hazardous area power carts eliminate need
for time-consuming area declassification and
equipment monitoring
A
C
B Power Cord Holder
Plant turnarounds can be complex, chaotic and
costly events. During your next shutdown, turn to
Cooper Crouse-Hinds for safe, reliable electrical
power equipment that ensures efficient and
successful operations.
Receptacles
ENR
CPS
CES
FSQC
B
A
Design Features
Cart 2
Width: 28”
Length: 14”
Height: 58”
Cart / Skid 1
Width: 30”
Length: 40”
Height: 58”
Non-Hazardous
Cart / Skid 2
Width: 42”
Length: 46”
Height: 58”
Cart / Skid 3
Width: 40”
Length: 62”
Height: 58”
Cart / Skid 4
Width: 33”
Length: 62”
Height: 58”
5
Portable Power Solutions for Plant Turnarounds
Portable GFCI
Ark•Gard™ Series
Portable ENR-GFCI
Assemblies
Design Features
• Provides hazardous location
earth leakage protection to
maximize safety of plant
personnel
Portable ENR-GFCI
Assemblies are used:
• To interrupt a circuit when
a ground fault is detected
on portable equipment
which may be handled by
personnel in hazardous
locations
• Solution to OSHA’s
requirements for GFCI
protection when using
portable equipment in
hazardous areas
• LED indicator light provides
indication that the receptacle
is energized and ready for use
• With electrical equipment
such as portable
hazardous-rated hand
lamps
• Available with either a red or
green LED indicator light to
provide indication that the
receptacle is energized and
ready for use
• Suitable for use in Class I
Division 1 and 2 locations
Cable Assemblies
Design Features
Portable GFCI Cable
Assemblies allow for:
• Improve Safety - earth
leakage protection provides
assurance that personnel and
equipment are protected from
ground fault hazards when
performing maintenance
• Non-hazardous equipment
connections with
hazardous receptacles
when areas have been
declassified or hot work
permits issued
• Increased Reliability construction meets Cooper
Crouse-Hinds superior quality
standards
• Earth leakage personnel
protection when operating
equipment such as drills,
saws and hand lamps
• Increased Time Savings turn-key solution eliminates
need for hazardous plugs to
be installed on non-hazardous
power tools
• Increased Flexibility available with a variety of
plug options to mate with
a range of installed base
of Cooper Crouse-Hinds
receptacles
• Assemblies still consist
of the same high quality
components that make up the
industry-leading Ark•Gard
series
Ordering Information
Ordering Information
Amp
20
6
Pilot Light
Portable
ENR-GFCI Cat. #
Red LED
ENR22201 PGF1 RLED
Green LED
ENR22201 PGF1 GLED
Plug Style
Plug Pin
Configuration
Plug
Ratings
Group Trip
Current
Cord
Length
Cord Gauge
Cable Assembly Cat. #
ENP5201
NEMA
5-20
20 Amp
125 Volt
4-6 mA
2’
12/3 AWG
ENP5201 GFI
ENP5151
NEMA
5-20
15 Amp
125 Volt
4-6 mA
2’
12/3 AWG
ENP5151 GFI
CPP516
UL 1686
2W3P
20 Amp
125 Volt
4-6 mA
2’
12/3 AWG
CPP516 GFI
CPP516
UL 1686
2W3P
20 Amp
240 Volt
4-6 mA
2’
12/3 AWG
CPP516 GFI 240V
7
For more information:
If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor,
Sales Office, or Customer Service Department.
U.S. (Global Headquarters):
Cooper Crouse-Hinds
Wolf & Seventh North Streets
Syracuse, NY 13221
(866) 764-5454
FAX: (315) 477-5179
FAX Orders Only: (866) 653-0640
crouse.customerctr@cooperindustries.com
Canada:
Cooper Crouse-Hinds Canada
Toll Free: (800) 265-0502
FAX: (800) 263-9504
FAX Orders Only: (866) 653-0645
Mexico/Latin America/Caribbean:
Cooper Crouse-Hinds, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4020
mxmercadotecnia@cooperindustries.com
Europe (Germany):
Cooper Crouse-Hinds GmbH
49 (0) 6271 806-500
49 (0) 6271 806-476
info-ex@ceag.de
Middle East (Dubai):
Cooper Crouse-Hinds LLC
971 4 4272500
FAX: 971 4 4298521
Singapore:
Cooper Crouse-Hinds Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
chsi-sales@cooperindustries.com
China:
Cooper Crouse-Hinds Pte. Ltd.
86-21-2899-3600
FAX: 8-21-2899-4055
cchsales@cooperindustries.com
Korea:
Cooper Crouse-Hinds Korea
82-2 3484-6783
82-2-3484-6778
CCHK-sales@cooperindustries.com
Australia:
Cooper Electrical Australia
61-2-8787-2777
FAX: 61-2-9609-2342
CEASales@cooperindustries.com
India:
Cooper India Pvt. Ltd.
91-124-4683888
FAX: 91-124-4683899
cchindia@cooperindustries.com
www.crouse-hinds.com
Cooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
©2012 Cooper Industries, Inc.
Your Authorized Cooper Crouse-Hinds Distributor is:
Cooper Industries, Ltd.
600 Travis, Ste. 5800
Houston, TX 77002-1001
P: 713-209-8400
www.cooperindustries.com
5033-0212
Printed in USA
Download