Voltage Regulators Technical Data TD225002EN Effective XXX 2015 Supersedes 240-40 August 2012 COOPER POWER SERIES Communications Point Data Base for Communications Protocol 2179 For use with Eaton’s Cooper Power series CL-7 Voltage Regulator Control CL-7 Cooper 2179 Device Profile Data Dictionary CL-7 2179 Map Points June 3, 2015 v2.00 THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE PROPERTY OF EATON. UNAUTHORIZED REPRODUCTION OR MODIFICATION IS PROHIBITED. Document 1.00 2.00 Date 6/21/2013 6/3/2015 Description Initial Release Updates for Summer 2015 release This document references the "CL7 Default" point map available in the ProView NXG software. Page 1 Cover Page CL-7 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Binary Input Status Description VR1 Bandwidth Low VR1 Bandwidth High VR1 Voltage Limiter Low VR1 Voltage Limiter High Voltage Reduction Active VR1 Auto Operation Blocking Status Blocked (Follows FC069) VR1 HMI LED Auto Tap Blocked ON VR1 System Power Direction Indeterminate VR1 System Power Direction Reverse VR1 Control Power Direction Reverse VR1 Blocking Relay Active VR1 HMI LED Neutral Position On VR1 HMI Switch Auto/Manual Auto HMI Switch Supervisory Off HMI LED Alarm On HMI LED Warning On HMI LED Diagnostic Error On VR1 Motor Trouble Tap To Neutral Active Soft Add-Amp Active AltConfigActive Configurable Logic Output from SCADA Tap to Neutral Activate Configurable Logic Output from SCADA Voltage Reduction Level 1 Activate Configurable Logic Output from SCADA Voltage Reduction Level 2 Activate Configurable Logic User Defined LED 1 On Configurable Logic User Defined LED 2 On Configurable Logic User Defined LED 3 On Configurable Logic Point 01 to SCADA Configurable Logic Point 02 to SCADA Configurable Logic Point 03 to SCADA Configurable Logic Point 04 to SCADA No Assignment Register Bit ID 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 2-Bit Status Sequence Simple Status Sequence 00 01 02 03 04 0 (0x0) 05 06 07 48(0x30) 08 09 10 11 12 1 (0x1) 13 14 15 00 01 02 03 04 2 (0x2) 05 06 07 49(0x31) 08 09 10 11 12 3 (0x3) 13 14 15 Page 2 Basic Scan, Status CL-7 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Counters Description VR1 Operations Counter VR1 Operations 24HR Counter VR1 Operations 30DY Counter VR1 Operations Month Counter VR1 Operations Last Month Counter VR1 Operations Year Counter VR1 Operations Last Year Counter VR1 TPI Neutral Resynch Counter VR1 Lower to Neutral Sync Retry Counter VR1 Raise to Neutral Sync Retry Counter VR1 Taps Past 16R Counter VR1 Taps Past 16L Counter Measured/Incremental TPI Mismatch Count COM1 Rx Message Counter COM2 Rx Message Counter COM1 Tx Message Counter COM2 Tx Message Counter COM1 Message Error Counter COM2 Message Error Counter Index Sequence 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 64 (0x40) 65 (0x41) 66 (0x42) 67 (0x43) 68 (0x44) 69 (0x45) 70 (0x46) 71 (0x47) 72 (0x48) 73 (0x49) 74 (0x4A) 75 (0x4B) 76 (0x4C) 77 (0x4D) 78 (0x4E) 79 (0x4F) 80 (0x50) 81 (0x51) 82 (0x52) Page 3 Basic Scan, Counters CL-7 Cooper 2179 Device Profile Data Dictionary INPUT SUBSYSTEM Analog Inputs Description VR1 Load Voltage Secondary VR1 Load Voltage Primary VR1 Compensated Voltage Secondary VR1 Load Current Primary VR1 Source Voltage Secondary VR1 Source Voltage Primary VR1 Tap Position VR1 Percent Reg VR1 Power Factor VR1 KVA Load VR1 kW Load VR1 KVAR Load Frequency VR1 Harm Total Voltage Harmonics VR1 Harm Total Current Harmonics VR1 kWh Forward VR1 KWH Reverse VR1 KQH Forward VR1 KQH Reverse VR1 Operation Counter VR1 Load Current Real VR1 Load Current Reactive VR1 Phase Angle Voltage Reduction In Effect Active Configuration Active Adaptive Add Amp Level Index Sequence Scale Factor Units 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 128 (0x80) 129 (0x81) 130 (0x82) 131 (0x83) 132 (0x84) 133 (0x85) 134 (0x86) 135 (0x87) 136 (0x88) 137 (0x89) 138 (0x8A) 139 (0x8B) 140 (0x8C) 141 (0x8D) 142 (0x8E) 143 (0x8F) 144 (0x90) 145 (0x91) 146 (0x92) 147 (0x93) 148 (0x94) 149 (0x95) 150 (0x96) 151 (0x97) 152 (0x98) 153 (0x99) 10 100 10 10 10 100 1 10 1000 10 10 10 100 10 10 1 1 1 1 1 10 10 1 10 1 1 Volts kVolts Volts Amps Volts kVolts -% -kVA kW kvar Hz % % kWHr kWHr kvarHr kvarHr -Amps Amps Degrees % % -- Page 4 Basic Scan, Analogs CL-7 Cooper 2179 Device Profile Data Dictionary OUTPUT SUBSYSTEM Select-Before-Operate Points Description VR1 Raise Tap * VR1 Lower Tap * Auto Block Enable VR1 Source Side Voltage Calculation Interval Operations Counters Enable VR1 Operations Counter Month Reset * VR1 Operations Counter Year Reset * VR1 Operations Counter 24HR Reset * VR1 Operations Counter 30DY Reset * VR1 Operations Counter Last Month Reset * VR1 Operations Counter Last Year Reset * VR1 TPI Neutral Mismatch Reset * VR1 Lower To Neutral Sync Retry Count Reset * VR1 Raise To Neutral Sync Retry Count Reset * VR1 Taps Past 16L Counter Reset * VR1 Taps Past 16R Counter Reset * Rx COM1 Counter Reset * Rx COM2 Counter Reset * Tx COM1 Counter Reset * Tx COM2 Counter Reset * Message Error COM1 Counter Reset * Message Error COM2 Counter Reset * Reset Energy All * Reset All Demand Values * Event Recorder Enable Data Profiler Enable Data Profiler Snapshot * Tap To Neutral Feature Enable PMT Mode A Enable PMT Mode B Enable PMT Mode A Test * PMT Mode B Test * Data Alarms Enable Status Alarms Enable VR1 Time On Tap Reset * Top Side Port LoopShare Enabled Bottom Side Port LoopShare Enabled Leader/Follower Enable Register Sequence 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 0 (0x0) 1 (0x1) 2 (0x2) 3 (0x3) 4 (0x4) 5 (0x5) 6 (0x6) 7 (0x7) 8 (0x8) 9 (0x9) 10 (0xA) 11 (0xB) 12 (0xC) 13 (0xD) 14 (0xE) 15 (0xF) 16 (0x10) 17 (0x11) 18 (0x12) 19 (0x13) 20 (0x14) 21 (0x15) 22 (0x16) 23 (0x17) 24 (0x18) 25 (0x19) 26 (0x1A) 27 (0x1B) 28 (0x1C) 29 (0x1D) 30 (0x1E) 31 (0x1F) 32 (0x20) 33 (0x21) 34 (0x22) 35 (0x23) 36 (0x24) 37 (0x25) Page 5 Conditioned by Supervisory State Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes SBO CL-7 Cooper 2179 Device Profile Data Dictionary OUTPUT SUBSYSTEM Select-Before-Operate Points Configurable Logic Output from SCADA Tap to Neutral Activate Configurable Logic Output from SCADA Voltage Reduction Level 1 Activate Configurable Logic Output from SCADA Voltage Reduction Level 2 Activate Configurable Logic Output from SCADA 1 Configurable Logic Output from SCADA 2 Configurable Logic Output from SCADA 3 Configurable Logic Output from SCADA 4 HMI Remote Security Override Mode 38 39 40 41 42 43 44 45 38 (0x26) 39 (0x27) 40 (0x28) 41 (0x29) 42 (0x2A) 43 (0x2B) 44 (0x2C) 45 (0x2D) Yes Yes Yes Yes Yes Yes Yes Yes * Momentary/Self Resetting Page 6 SBO Technical Data TD225002EN Communications Point Data Base Effective June 2015 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD225002EN June 2015 Supersedes R225-70-29 (6/2013) Eaton is a registered trademark. All other trademarks are property of their respective owners. For Eaton's Cooper Power series CL-7 voltage regulator control information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.