CYME Software Seminar CYME 7.1 and 7.2 New Features February 23, 2015 – Hotel Marriott, Ras Abboud – Doha, Qatar 8:00 am – 8:30 am Registration and Continental Breakfast 8:30 am – 9:00 am Welcome Richard Dourian, EATON / CYME 9:00 am – 10:00 am Detailed Cable Modeling and Accurate Impedance Calculation Construction details for 3C and 1C cables Standard ANSI and IEC conductor sizes. Positive and Zero Sequence Impedance dynamically computed Conductor material and Insulation Library Magnetic Duct effects Single core cable installation details Protective Device Database 10:00 am –10:30 am New database structure for Fuses, High and Low Voltage circuit breakers Tree view classification by Manufacturer, Trip Unit, Frame and Sensor / Plug Ratings ANSI and IEC database of protective devices Database, Inventory and Favorites Quick Device Select Button Motor Starting New equivalent circuit parameter estimation methods including Cage Factor. The chart selector now includes Apparent, Active and Reactive Power Alert reports for under voltage conditions Harmonic Analysis Transformer K-Factor calculations Filter Design reports including losses, inductor currents and capacitor voltages. Waveforms and bar charts of non linear devices 10:30 am – 11:00 am Equipment Rating Verification 11:00 am – 11:30 am Runs both Power Flow and Short Circuit analysis Evaluates cable withstand and protective device interrupting ratings Bus Continuous, Peak Asymmetrical and Symmetrical ratings. Calculates worst case for all possible fault conditions Abnormal conditions report and color coding on the one line diagram. Refreshment Break 11:30 am – 12:30 pm Batch Analysis Scenario Manager Multiple analysis on loaded or previously saved studies Worst case conditions summary Reports for each analysis Complete Report Generates any analysis report in a Microsoft Word formatted document. Software version, revision number, title, author, company, and description are included in the report, header and footer. Any report can be included or not 12:30 pm – 1:30 pm Lunch Page 1/2 CYME Software Seminar CYME 7.1 and 7.2 New Features 1:30 pm – 2:00 pm General Enhancements and Features 2:00 pm – 2:30 pm Distributed Line Modeling Quick Swing Angle reference selection for Transient Stability Negative Sequence impedance for Generators and Sources Device Voltage mismatch violations Data entry Status Automatic Naming Pattern of devices Explorer bar for quick drag and drop of devices Symbol lock function for multiple device addition Quick Access Chart Button CYME 7.2 New Features 2:30 pm – 3:00 pm Advanced Cable Modeling Low Voltage Cable Sizing IEC 61363 Short Circuit Analysis for off shore applications Distance Protection Enhanced ANSI and IEC Short Circuit Reports Enhanced Batch Analysis and Complete Report options Quick Database editing from network settings Refreshment Break 3:00 pm – 3:30 pm Discussion and Concluding Remarks Page 2/2